Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Thorac Cardiovasc Surg ; 130(2): 378-83, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16077402

RESUMO

OBJECTIVES: Respiratory support for patients recovering from cardiopulmonary bypass and cardiac surgery uses large tidal volumes and a minimal level of positive end-expiratory pressure. Recent data indicate that these ventilator settings might cause pulmonary and systemic inflammation in patients with acute lung injury. We examined the hypothesis that high tidal volumes and low levels of positive end-expiratory pressure might worsen the inflammatory response associated to cardiopulmonary bypass. METHODS: Forty patients undergoing elective coronary artery bypass were randomized to be ventilated after cardiopulmonary bypass disconnection with high tidal volume/low positive end-expiratory pressure (10-12 mL/kg and 2-3 cm H2O, respectively) or low tidal volume/high positive end-expiratory pressure (8 mL/kg and 10 cm H2O, respectively). Interleukin 6 and interleukin 8 levels were measured in the bronchoalveolar lavage fluid and plasma. Samples were taken before sternotomy (time 0), immediately after cardiopulmonary bypass separation (time 1), and after 6 hours of mechanical ventilation (time 2). RESULTS: Interleukin 6 and interleukin 8 levels in the bronchoalveolar lavage fluid and plasma significantly increased at time 1 in both groups but further increased at time 2 only in patients ventilated with high tidal volume/low positive end-expiratory pressure. Interleukin 6 and interleukin 8 levels in the bronchoalveolar lavage fluid and in the plasma at time 2 were higher with high tidal volume/low positive end-expiratory pressure than with low tidal volume/high positive end-expiratory pressure. CONCLUSION: Mechanical ventilation might be a cofactor able to influence the inflammatory response after cardiac surgery.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Interleucina-6/imunologia , Interleucina-8/imunologia , Respiração Artificial/efeitos adversos , Idoso , Líquido da Lavagem Broncoalveolar/química , Líquido da Lavagem Broncoalveolar/imunologia , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Feminino , Humanos , Mediadores da Inflamação , Interleucina-6/análise , Interleucina-8/análise , Masculino , Pessoa de Meia-Idade , Respiração com Pressão Positiva/efeitos adversos , Respiração com Pressão Positiva/métodos , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA