Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Clin Transplant ; 36(8): e14742, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35678134

RESUMO

End-stage kidney disease is frequently associated with left ventricular hypertrophy (LVH), a condition more prevalent in the elderly, that may increase mortality after renal transplantation (RTx). Previous studies suggested that mTOR inhibitors (mTORi) can improve LVH, but this has never been tested in elderly kidney transplant recipients. In this prospective randomized clinical trial, we analyzed the impact of Everolimus (EVL) on the reversal of LVH after RTx in elderly recipients (≥60 years) submitted to different immunosuppressive regimens: EVL/lowTacrolimus (EVL group, n = 53) or mycophenolate sodium/regularTacrolimus (MPS group, n = 47). Patients performed echocardiograms (Echo) up to 3 months after RTx and then annually. At baseline, mean age was 65±3 years in both groups and LVH was observed in 63.6% of patients in EVL group and in 61.8% of MPS group. Last Echo was performed at mean time of 47 and 49 months after RTx in EVL and MPS groups, respectively (P = .34). LVH regression was observed in 23.8% (EVL group) and 19% (MPS group) of patients (P = 1.00). Mean eGFR, blood pressure, and use of RAS blockers were similar between groups throughout follow-up. EVL did not improve LVH in this cohort, and this lack of benefit may be attributed to concomitant use of TAC, senescence, or both.


Assuntos
Transplante de Rim , Idoso , Everolimo/uso terapêutico , Humanos , Hipertrofia Ventricular Esquerda/tratamento farmacológico , Hipertrofia Ventricular Esquerda/etiologia , Imunossupressores/uso terapêutico , Transplante de Rim/efeitos adversos , Inibidores de MTOR , Pessoa de Meia-Idade , Estudos Prospectivos , Sirolimo/uso terapêutico , Serina-Treonina Quinases TOR , Transplantados
2.
Echocardiography ; 27(10): 1233-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20584052

RESUMO

BACKGROUND: Intrapulmonary vascular dilatations (IVD) are microvascular pulmonary changes mediated by nitric oxide that cause right-to-left shunt and hypoxemia. Contrast-enhanced transthoracic echocardiography (cTTE) is the gold standard diagnostic test for IVD. OBJECTIVE: To evaluate contrast-enhanced transesophageal echocardiography (cTEE) in the diagnosis and grading of IVD. METHODS: A study group (SG) of 63 cirrhotic patients were compared to 20 shunt-free control subjects (CG). Both groups underwent cTEE and cTTE using intravenous injections of agitated saline solution for contrast tests. Patients with patent foramen ovale, when detected, were excluded. Late appearance of microbubbles in the left atrium was diagnostic of pulmonary shunt (positive contrast test) and was graded as trivial, mild, moderate or severe by cTEE. Contrast tests were negative in 7 patients (35%) and trivial in the remaining 13 (65%) in CG, so only contrast grades ≥ mild were considered to be positive IVD tests in the SG. Gasometric change was expressed as the alveolar-arterial oxygen tension difference (A-aO2D) and was considered abnormally high at values >20 mmHg. RESULTS: SG: positive IVD tests were present in 23 patients (36%) by cTTE and 47 (75%) by cTEE (P < 0.001). These patients showed A-aO2D values significantly higher than those with negative IVD tests (P < 0.02) and were directly proportional to the contrast grade. cTEE allowed the diagnosis of IVD in three additional patients with high A-aO2D that were not detected by cTTE. CONCLUSION: cTEE enabled diagnosis of IVD in a greater number of patients with gasometric changes compared to cTTE. The contrast effect grade by cTEE seems to be proportional to IVD magnitude.


Assuntos
Ecocardiografia Transesofagiana/métodos , Síndrome Hepatopulmonar/diagnóstico por imagem , Microbolhas , Artéria Pulmonar/diagnóstico por imagem , Meios de Contraste , Dilatação Patológica/diagnóstico por imagem , Dilatação Patológica/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Echocardiography ; 26(10): 1204-10, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19725861

RESUMO

BACKGROUND: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. METHODS: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. RESULTS: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). CONCLUSION: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise.


Assuntos
Valva Aórtica/transplante , Bioprótese , Criopreservação/métodos , Teste de Esforço , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas , Stents , Adulto , Idoso , Prótese Vascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Ultrassonografia
5.
J Am Soc Echocardiogr ; 16(11): 1191-3, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14608293

RESUMO

We describe an unusual case of extracardiac mass in a patient who was assymptomatic and submitted to an open-chest coronary artery bypass operation 5 years previously. Transthoracic and transesophageal echocardiography revealed a rounded mass compressing the right atrium with a thick contour surrounding a heterogeneous center, suggestive of foreign body. Magnetic resonance imaging identified the mass as a pericardial cyst. Operation revealed a fibrinous cyst encapsulating a sponge. This case illustrates the central role of echocardiography for the diagnosis and treatment of patients with suspected retained surgical sponges.


Assuntos
Ecocardiografia Transesofagiana , Ecocardiografia , Reação a Corpo Estranho/etiologia , Tampões de Gaze Cirúrgicos/efeitos adversos , Doença Crônica , Ponte de Artéria Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Diagnóstico Diferencial , Reação a Corpo Estranho/diagnóstico , Átrios do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Masculino , Cisto Mediastínico/diagnóstico , Cisto Mediastínico/etiologia , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Radiografia
6.
J Am Soc Echocardiogr ; 16(5): 469-75, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12724657

RESUMO

BACKGROUND: Heterogeneous results of coronary flow velocity reserve (CFVR) to percutaneous procedures have been reported and the impact of transesophageal echocardiographic evaluation of CFVR in predicting restenosis has not been completely established. METHODS AND RESULTS: We studied 20 control volunteers and 51 patients with left anterior descending coronary artery stenosis to determine the CFVR response to left anterior descending coronary artery stenting, the clinical markers of persistent CFVR impairment, and its value in predicting restenosis. Prestent CFVR was lower in the stenosis group than in control volunteers (1.89 +/- 0.66 vs 3.82 +/- 1.15; P <.001). Although there was a significant increase of CFVR after stenting (2.58 +/- 0.76; P <.001 vs prestent), it remained depressed in 53% of patients and was independently related to multivessel disease (odds ratio, 0.14; 95% confidence interval 0.03-0.55; P =.005), age (odds ratio, 1.07; 95% confidence interval 0.99-1.15; P =.056), and prestent CFVR (odds ratio, 3.78; 95% confidence interval 0.99-14.42; P =.051). CFVR measured both before and early after stenting did not differ between patients with and without restenosis. CONCLUSIONS: CFVR impairment occurs in a large proportion of patients despite successful stenting and appears to be consequent of the extent of atherosclerotic coronary disease. Periprocedural CFVR conferred no predictive value for subsequent intrastent restenosis.


Assuntos
Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Idoso , Velocidade do Fluxo Sanguíneo , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional , Stents
7.
Clin Rheumatol ; 31(9): 1331-8, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22692396

RESUMO

Antiphospholipid antibodies (aPL) and antiphospholipid syndrome (APS) have been described in primary Sjögren's syndrome (pSS) with controversial findings regarding aPL prevalence and their association with thrombotic events. We evaluated 100 consecutive pSS patients (American-European criteria) and 89 age-gender-ethnicity-matched healthy controls for IgG/IgM anticardiolipin (aCL), IgG/IgM anti-beta2-glycoprotein-I (aß2GPI), and lupus anticoagulant (LA) (positivity according to APS Sydney's criteria). Clinical analysis followed standardized interview and physical examination assessing thrombotic and nonthrombotic APS manifestations and thrombosis risk factors. aPLs were detected in 16 % patients and 5.6 % controls (p = 0.035). LA was the most common aPL in patients (9 %), followed by aß2GPI (5 %) and aCL (4 %). Thrombotic events occurred in five patients [stroke in two, myocardial infarction in one and deep-vein thrombosis (DVT) in four], but in none of controls (p = 0.061). Mean age at time of stroke was 35 years. Three patients with thrombotic events (including the two with stroke) had APS (Sydney's criteria) and were positive exclusively for LA. Comparison of patients with (n = 16) and without (n = 84) aPL revealed similar mean age, female predominance, and ethnicity (p > =0.387). Frequencies of livedo reticularis (25 vs. 4.8 %, p = 0.021), stroke (12.5 vs. 0 %, p = 0.024), and DVT (18.8 vs. 1.2 %, p = 0.013) were significantly higher in APL + patients. Conversely, frequencies of hypertension, dyslipidemia, diabetes, obesity, smoking, sedentarism, and hormonal contraception were similar in patients with or without aPL (p ≥ 0.253). Our study identified LA as an important marker for APS in pSS, particularly for stroke in young patients, warranting routine evaluation of these antibodies and rigorous intervention in modifiable risk factors.


Assuntos
Inibidor de Coagulação do Lúpus/sangue , Inibidor de Coagulação do Lúpus/imunologia , Síndrome de Sjogren/complicações , Síndrome de Sjogren/imunologia , Acidente Vascular Cerebral/imunologia , Trombose Venosa/imunologia , Adolescente , Adulto , Idoso , Anticorpos Antifosfolipídeos/química , Síndrome Antifosfolipídica/metabolismo , Cardiolipinas/química , Estudos de Casos e Controles , Feminino , Humanos , Imunoglobulina G/imunologia , Imunoglobulina M/imunologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Acidente Vascular Cerebral/complicações , Fatores de Tempo , Trombose Venosa/complicações
8.
Arq Bras Cardiol ; 88(4): 396-401, 2007 Apr.
Artigo em Inglês, Português | MEDLINE | ID: mdl-17546267

RESUMO

OBJECTIVES: To describe pulmonary venous flow patterns using transthoracic echocardiograms on children suffering from different congenital heart defects with increased pulmonary flow. METHODS: Prospective study and consecutive selection of children suffering from congenital heart defects with increased pulmonary flow. The transthoracic, apical view, Doppler echocardiogram was used, positioning the sample-volume at the lower pulmonary vein, 4mm from its junction with the left atrium. The data analyzed included: dominant systolic or diastolic pulmonary venous flow and atrial contraction waveform characteristics, designated as "A" for absent and "R" for reversed. RESULTS: The study included twenty-nine patients with a mean age of 29.9 +/- 58.9 months, suffering from the following congenital heart conditions: interatrial and interventricular communication defects, patent ductus arteriosus, atrioventricular septal defects, total transposition of the great arteries and truncus arteriosus. All the patients presented a continuous pattern of high velocity pulmonary venous flow. Nine patients presented a dominant systolic waveform (31%), eighteen presented a dominant diastolic wave form (62%) and 2 patients had systolic and diastolic wave forms of equal amplitude (7%). Six patients (21%) presented a R atrial contraction waveform and 23 (79%) presented an A atrial contraction waveform. CONCLUSION: Congenital heart diseases with increased pulmonary flow present a continuous pattern of high velocity pulmonary venous flow with alterations mainly in the atrial contraction reversal pattern.


Assuntos
Cardiopatias Congênitas/fisiopatologia , Circulação Pulmonar/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pré-Escolar , Ecocardiografia Doppler de Pulso , Ecocardiografia Transesofagiana , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Estudos Prospectivos
9.
J Am Soc Echocardiogr ; 20(10): 1141-8, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17588714

RESUMO

OBJECTIVES: The objective was to analyze the diagnostic value of the echocardiographic methods used for quantification of mitral regurgitation (MR) in patients with mitral valve prolapse (MVP) or rheumatic heart disease (RHD). METHODS: The study included 50 patients with MR (mean age of 46.1 years; 35 women), 27 (54%) with RHD and 23 (46%) with MVP. Quantification of the mitral valve regurgitation was obtained by regurgitant orifice area (ROA) and regurgitant volume (RV) by the flow convergence region (FCR) and two-dimensional Doppler echocardiographic methods, regurgitant fraction, jet area (JA), jet area/left atrial area ratio (JA/LAA), and vena contracta (VC). Patients were clinically followed to identify cardiovascular events. Data were analyzed by Pearson, kappa, and receiver operator characteristic curve tests; significance was defined as a P value less than .05. RESULTS: The correlation between the two methods for ROA and RV were r = 0.79 and r = 0.80, respectively, and between these parameters and regurgitant fraction, VC, JA, and JA/LAA varied from r = 0.54 to r = 0.94 (P lt; .05); the agreement varied from kappa = 0.19 to kappa = 0.83. The highest accuracy to identify patients with clinically significant MR (events at follow-up) was 96% for ROA by FCR, 94% for VC, 86% for RV by FCR, and 86% for JA. No method showed a significant difference between MVP and RHD. CONCLUSIONS: The methods analyzed had significant correlation and good agreement. ROA by FCR and VC had the best performance to identify severe MR; no significant difference between MVP and RHD was observed.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Cardiopatia Reumática/diagnóstico por imagem , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Cardiopatia Reumática/fisiopatologia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA