Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Clin Chem Lab Med ; 56(1): 113-119, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-28672769

RESUMO

BACKGROUND: Vasopressin and adrenomedullin and their stable by-products copeptin and midregional part of proadrenomedullin (MR-proADM) are promising biomarkers for the development of preeclampsia. However, clinical use is hampered by the lack of trimester-specific reference intervals. We therefore estimated reference intervals for copeptin and MR-proADM in disease-free Dutch women throughout pregnancy. METHODS: Apparently healthy low risk pregnant women were recruited. Exclusion criteria included current or past history of endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, hemolysis elevated liver enzymes and low platelets, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded from analyses. Blood samples were collected at 9-13 weeks (n=98), 27-29 weeks (n=94) and 36-39 weeks (n=91) of gestation and at 4-13 weeks post-partum (PP) (n=89). Sixty-two women had complete data during pregnancy and PP. All analyses were performed on a Kryptor compact plus. RESULTS: Copeptin increases during pregnancy, but 97.5th percentiles remain below the non-pregnant upper reference limit (URL) provided by the manufacturer. MR-proADM concentrations increase as well during pregnancy. In trimesters 2 and 3 the 97.5th percentiles are over three times the non-pregnant URL provided by the manufacturer. CONCLUSIONS: Trimester- and assay-specific reference intervals for copeptin and MR-proADM should be used. In addition, consecutive measurements and the time frame between measurements should be considered as the differences seen with or in advance of preeclampsia can be expected to be relatively small compared to the reference intervals.


Assuntos
Adrenomedulina/sangue , Glicopeptídeos/sangue , Gravidez/sangue , Precursores de Proteínas/sangue , Ensaio de Imunoadsorção Enzimática/normas , Feminino , Humanos , Estudos Longitudinais , Valores de Referência
2.
Clin Chem Lab Med ; 54(7): 1239-46, 2016 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-26641966

RESUMO

BACKGROUND: Trimester-specific reference intervals for TSH are recommended to assess thyroid function during pregnancy due to changes in thyroid physiology. Laboratories should verify reference intervals for their population and assay used. No consistent upper reference limit (URL) for TSH during pregnancy is reported in literature. We investigated the use of non-pregnant reference intervals for TSH, recommended during pregnancy by current Dutch guidelines, by deriving trimester-specific reference intervals in disease-free Dutch pregnant women as these are not available. METHODS: Apparently healthy low risk pregnant women were recruited via midwifery practices. Exclusion criteria included current or past history of thyroid or other endocrine disease, multiple pregnancy, use of medication known to influence thyroid function and current pregnancy as a result of hormonal stimulation. Women who were TPO-antibody positive, miscarried, developed hyperemesis gravidarum, hypertension, pre-eclampsia, HELLP, diabetes or other disease, delivered prematurely or had a small for gestational age neonate were excluded. Blood samples were collected at 9-13 weeks (n=99), 27-29 weeks (n=96) and 36-39 weeks (n=96) of gestation and at 4-13 weeks post-partum (n=95). Sixty women had complete data during pregnancy and post-partum. All analyses were performed on a Roche Cobas e601 analyser. RESULTS AND CONCLUSIONS: In contrast to current Dutch guidelines, the 97.5th percentiles of TSH in the first (3.39 mIU/L) and second trimesters (3.38 mIU/L) are well under the non-pregnant URL of 4.0 mIU/L. The higher TSH in the third trimester (97.5th percentile 3.85 mIU/L) is close to the current non-pregnant URL of 4.0 mIU/L. Absolute intra-individual TSH is relatively stable during pregnancy and post-partum as individuals tracked within the tertile assigned in trimester 1. Even small deviations within the population reference interval may indicate subtle thyroid dysfunction.


Assuntos
Trimestres da Gravidez/sangue , Glândula Tireoide/fisiologia , Tireotropina/sangue , Tiroxina/sangue , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Recém-Nascido , Estudos Longitudinais , Medições Luminescentes , Gravidez , Valores de Referência , Testes de Função Tireóidea
3.
Clin Chem Lab Med ; 53(3): 461-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25283138

RESUMO

BACKGROUND: Treatment of congenital adrenal hyperplasia due to 21-hydroxylase deficiency can be monitored by salivary androstenedione (A-dione) and 17α-hydroxyprogesterone (17OHP) levels. There are no objective criteria for setting relevant target values or data on changes of 17OHP and A-dione during monitoring. METHODS: We evaluated A-dione and 17OHP levels in nearly 2000 salivary samples collected during long-term treatment of 84 paediatric patients with classic 21-hydroxylase deficiency. RESULTS: A-dione and 17OHP levels and its ratio 17OHP/A-dione remained constant from 4 to 11 years with no sex-related differences. During puberty, A-dione and 17OHP levels both increased, starting at earlier age in girls than in boys. The ratio 17OHP/A-dione declined. Normalised A-dione concomitant with elevated 17OHP [1.43 nmol/L (0.46-4.41) during prepuberty; 2.36 nmol/L (0.63-8.89) for boys and 1.99 nmol/L (0.32-6.98) for girls during puberty] could be obtained with overall median glucocorticoid doses of 11-15 mg/m2/day. A-dione levels above the upper reference limit (URL), suggesting undertreatment, coincided with 17OHP levels ≥10 times URL. The percentage of A-dione levels above URL was 16% at ages 4-8 years, but increased to 31% for girls at 16 years and 46% for boys at 17 years. CONCLUSIONS: Normalised A-dione consistent with 17OHP three times URL during prepuberty and normalised A-dione consistent with 4-6 times URL during puberty could be obtained by moderate glucocorticoid dosages. A constant 17OHP/A-dione ratio during prepuberty suggested absence of adrenarche. During puberty, a higher percentage of samples met the criteria for undertreatment, especially of boys.


Assuntos
17-alfa-Hidroxiprogesterona/análise , Hiperplasia Suprarrenal Congênita/metabolismo , Androstenodiona/análise , Puberdade/metabolismo , Saliva/química , Adolescente , Hiperplasia Suprarrenal Congênita/tratamento farmacológico , Criança , Pré-Escolar , Feminino , Glucocorticoides/farmacologia , Glucocorticoides/uso terapêutico , Humanos , Masculino , Estudos Retrospectivos , Saliva/efeitos dos fármacos
4.
Clin Chem Lab Med ; 50(1): 129-32, 2011 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-21973104

RESUMO

BACKGROUND: This study evaluated the diagnostic performance of naturally purified allergen-molecules compared to that of allergen-extracts for house dust mite, cat dander epithelium and dog dander. METHODS: In vitro tests for allergen-specific IgE were performed on the IMMULITE(®) 2000 in serum samples from 66 allergic patients. RESULTS: House dust mite: specificity for the allergen-extract (D1) and the allergen-molecules (nDer p 1, nDer f 1, nDer p 2 and nDer f 2) is comparable. The allergen-extract has a significantly higher sensitivity (100%) and total agreement (TA) (93%) relative to sensitivity (57%-70%) and TA (76%-81%) of the individual allergen-molecules. Cat dander epithelium: sensitivity (90%), specificity (96%) and TA (94%) of the allergen-molecule (nFel d 1) are comparable to those of the allergen-extract (E1). Dog dander: The allergen-molecule (nCan d 1) and allergen-extract (E5) have comparable specificity and TA. The allergen-extract has a lower sensitivity (52%) than the allergen-molecule (71%), although not significant (p=0.125). CONCLUSIONS: There is no diagnostic benefit of using allergen-molecules instead of allergen-extracts for initial allergy screening on cat dander epithelium and dog dander. However, use of these allergen-molecules might contribute to better standardization of the specific IgE tests. The studied allergen-molecules for house dust mite are of minor diagnostic value, because of loss of sensitivity.


Assuntos
Alérgenos , Gatos , Cães , Hipersensibilidade/diagnóstico , Testes Cutâneos/métodos , Adolescente , Adulto , Alérgenos/sangue , Alérgenos/imunologia , Animais , Feminino , Humanos , Imunoglobulina E/sangue , Masculino , Sensibilidade e Especificidade , Testes Cutâneos/normas
5.
Am J Clin Pathol ; 152(3): 392-398, 2019 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-31152542

RESUMO

OBJECTIVES: Calprotectin is a noninvasive biomarker that can distinguish inflammatory bowel disease from irritable bowel syndrome. We investigated four automated fecal calprotectin methods on five different platforms for their preanalytical process, analytical performance, and clinicopathologic correlation. METHODS: Four calprotectin methods (Bühlmann, EliA CN, EliA CN2, and DiaSorin) were performed on five platforms (Cobas 8000 E502, Phadia Immunocap 100 and 250, and Liaison and Liaison XL) in two hospital laboratories. RESULTS: Overall variation for the different extraction devices was less than 19% when feces were of normal consistency. Freeze-thawing of samples resulted in comparable results compared with fresh samples. The different methods had a good analytic correlation (R = 0.83-0.95). Their clinicopathologic correlation was comparable, but the Bühlmann method showed significantly higher calprotectin values in every patient category. CONCLUSIONS: The automated calprotectin methods showed a good performance and comparable clinicopathologic correlation. Due to lack of standardization, the numerical values differ for the various methods.


Assuntos
Fezes/química , Doenças Inflamatórias Intestinais/diagnóstico , Síndrome do Intestino Irritável/diagnóstico , Complexo Antígeno L1 Leucocitário/análise , Biomarcadores/análise , Diagnóstico Diferencial , Humanos , Reprodutibilidade dos Testes
6.
Pract Lab Med ; 4: 41-49, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28856192

RESUMO

OBJECTIVES: Lactate is a major parameter in medical decision making. During labor, it is an indicator for fetal acidosis and immediate intervention. In the Emergency Department (ED), rapid analysis of lactate/blood gas is crucial for optimal patient care. Our objectives were to cross-compare-for the first time-two point-of-care testing (POCT) lactate devices with routine laboratory results using novel tight precision targets and evaluate different lactate cut-off concentrations to predict metabolic acidosis. DESIGN AND METHODS: Blood samples from the delivery room (n=66) and from the ED (n=85) were analyzed on two POCT devices, the StatStrip-Lactate (Nova Biomedical) and the iSTAT-1 (CG4+ cassettes, Abbott), and compared to the routine laboratory analyzer (ABL-735, Radiometer). Lactate concentrations were cross-compared between these analyzers. RESULTS: The StatStrip correlated well with the ABL-735 (R=0.9737) and with the iSTAT-1 (R=0.9774) for lactate in umbilical cord blood. Lactate concentrations in ED samples measured on the iSTAT-1 and ABL-735 showed a correlation coefficient of R=0.9953. Analytical imprecision was excellent for lactate and pH, while for pO2 and pCO2 the coefficient of variation was relatively high using the iSTAT-1. CONCLUSION: Both POCT devices showed adequate analytical performance to measure lactate. The StatStrip can indicate metabolic acidosis in 1 µl blood and will be implemented at the delivery room.

7.
Sci Rep ; 5: 16302, 2015 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-26542612

RESUMO

In vitro glycolysis poses a problem during diabetes screening, especially in remote laboratories. Point-of-care analysis (POC) may provide an alternative. We compared POC, routine and STAT analysis and a feasible protocol during glucose tolerance test (GTT) for pregnancy diabetes (GDM) screening. In the routine protocol, heparin tubes were used and turn-around-time (TAT) was unsupervised. In the STAT protocol, tubes were processed immediately. The feasible protocol comprised of citrated tubes with a TAT of 1 hour. Outcome was defined as glucose concentration and clinical diagnosis. Glucose measured by POC was higher compared to routine analysis at t = 0 (0.25 mM) and t = 120 (1.17 mM) resulting in 17% more GDM diagnoses. Compared to STAT analysis, POC glucose was also higher, although less pronounced (0.06 and 0.9 mM at t = 0 and t = 120 minutes, respectively) and misclassification was only 2%. Glucose levels and clinical diagnosis were similar using the feasible protocol and STAT analysis (0.03 mM and -0.07 mM at t = 0 and t = 120, 100% identical diagnoses). POC is an viable alternative for STAT glucose analysis in GDM screening (sensitivity: 100%, specificity: 98%). A feasible protocol (citrated phlebotomy tubes with a TAT of 60 minutes) resulted in 100% identical outcome and provides the best alternative.


Assuntos
Diabetes Gestacional/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Glicemia/análise , Feminino , Teste de Tolerância a Glucose , Humanos , Gravidez , Sensibilidade e Especificidade
8.
Thyroid ; 25(6): 629-34, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25811973

RESUMO

BACKGROUND: In populations with mild iodine deficiency, the serum level of thyrotropin (TSH) is negatively and the serum free thyroxine (FT4) is positively associated with age. An ongoing decrease of TSH and increase of FT4 can be found after iodine supplementation. The aim of this study was to investigate whether there are current differences in the relation between thyroid function and age in relation to differences in iodine intake in the past. METHODS: Eight medical laboratories in several regions of The Netherlands, which are all iodine sufficient at present but with a difference in iodine status in the past, provided the results of all TSH and FT4 measurements performed from 2006 until 2011, resulting in 330,802 TSH and 103,940 FT4 measurements. RESULTS: The negative association between TSH and age in the elderly is only present in areas with a historical iodine deficiency (regression coefficients [RC] -0.008, 95% confidence interval [CI] -0.009; -0.007). In the historically iodine-sufficient population, TSH shows no obvious increase or decrease with age. In both the historically iodine-sufficient and iodine-deficient populations, FT4 levels were positively associated with age in the elderly (RC 0.009, 95% CI 0.008; 0.010 and RC 0.008, 95% CI 0.007; 0.010, respectively). CONCLUSIONS: There are differences in relation between thyroid function and age between populations with differences in iodine intake in the past, despite an adequate iodine status at present. This raises the question whether the present but also historical iodine status of a population should be taken into account when establishing the reference limits of TSH and FT4.


Assuntos
Iodo/deficiência , Tireotropina/sangue , Tiroxina/sangue , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Retrospectivos , Testes de Função Tireóidea , Adulto Jovem
9.
Clin Chem Lab Med ; 46(6): 863-71, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18601611

RESUMO

BACKGROUND: Consolidation of analyzers is an emerging issue in clinical chemistry. We evaluated the analytical performance of the Cobas 6,000 analyzer (Roche Diagnostics), which is considered a candidate for replacement of current Hitachi 917 analyzers and for consolidation of chemistry and immunochemistry. METHODS: The precision, accuracy, linearity and correlation with current field methods were evaluated according to Clinical and Laboratory Standards Institute protocols EP5, EP9 and EP10. A total of 31 routine chemistry assays and 18 immunoassays were studied. Accuracy and linearity were verified for 24 chemistry parameters using value-assigned trueness controls from the Dutch External Quality Assessment Scheme organizers. In addition, traceability to methods endorsed by the Joint Committee of Traceability in Laboratory Medicine was examined. RESULTS: All analytes met allowable precision criteria, apart from the low level for sodium and folate. Total coefficients of variation ranged between 0.6% and 4.4% for routine chemistry and between 0.8% and 5.8% for immunochemistry, apart from folate (12% at the low end). The correlation coefficients for comparison to current field methods were >0.975, except for magnesium and for six out of 18 immunochemistries. Recovery experiments indicated high recovery for most of the 24 routine chemistry assays. CONCLUSIONS: Considering the excellent precision data and the result equivalence for most assays, it can be concluded that Cobas 6,000 accommodates robust chemistry and immunochemistry, and has good potential for workstation consolidation in medium-sized laboratories.


Assuntos
Química Clínica/métodos , Testes de Química Clínica/métodos , Imunoensaio/métodos , Protocolos Clínicos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA