Anal Chem ; 87(17): 8781-8, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-26214104

RESUMO

Most conventional analytical tools for the assessment of protein-protein interactions yield information on the bulk sample. By employing the efficient separation of intact proteins, affinity capillary electrophoresis (ACE) can measure the interaction of components of heterogeneous proteins with a target protein. In this work, the hyphenation of ACE with mass spectrometry (MS) is presented as a novel, highly selective tool for the assessment of protein-protein interactions. The binding of the protease inhibitor aprotinin to trypsinogen was used as protein-protein affinity model. A trypsinogen sample comprising several modifications was analyzed using a background electrolyte of 25 mM ammonium acetate (pH 8.0) containing increasing concentrations of aprotinin (0-300 µM). A capillary coating of polybrene-dextran sulfate-polybrene (PB-DS-PB) was employed to prevent adsorption of the proteins to the capillary wall. The trypsinogen variants were separated and could be assigned based on detected molecular masses and relative migration. In presence of aprotinin, both free and aprotinin-bound trypsinogen were detected revealing a 1:1 binding stoichiometry. For most trypsinogen variants, shifts in electrophoretic mobility were observed upon raising the aprotinin concentration, allowing determination of their dissociation constants (Kd's). The interacting trypsinogen variants showed similar affinity toward aprotinin (Kd's of 3-9 µM), which were not significantly different from the values obtained with ACE-UV and were in agreement with an earlier reported value. The use of the ratio of obtained MS signal intensities of free and protein-protein complex for the determination of Kd's was also explored. Derived Kd values (20-104 µM) for the binding variants were similar to those obtained with direct-infusion MS, but higher and less precise as compared with values based on mobility shifts. The suitability of the ACE-MS methodology for the affinity profiling of heterogeneous protein samples was evaluated, and components with high, medium, or low affinity toward aprotinin could be successfully discriminated.


Assuntos
Técnicas de Química Analítica/métodos , Eletroforese Capilar , Espectrometria de Massas , Proteínas/química , Cromatografia de Afinidade , Modelos Biológicos
2.
Anal Bioanal Chem ; 401(10): 3275-81, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22012211

RESUMO

A capillary electrophoresis method with UV-absorbance detection was studied and optimized for the determination of underivatized amino acids in urine. To improve concentration sensitivity the utility of in-capillary analyte stacking via dynamic pH junction was investigated with phenylalanine (Phe) and tyrosine (Tyr) as model amino acids. Before sample injection, a plug of ammonium hydroxide solution was injected to enable analyte concentration. Samples were 1:1 (v/v) mixed with background electrolyte (1 M formic acid) prior to injection. The effect of the injected sample volume, and the injected ammonium hydroxide volume and concentration on analyte stacking and separation performance was investigated. The optimal volume of ammonium hydroxide depended on the injected sample volume. Using a dynamic pH junction good resolution (1.4) was obtained for a sample injection volume of 10% of the capillary (196 nl) with Phe and Tyr dissolved in water. Limits of detection (LODs) were 0.036 and 0.049 µM for Phe and Tyr, respectively. For urine samples, the optimized procedure comprised a 1.7-nl injection of 12.5% ammonium hydroxide, followed by a 196-nl injection of urine spiked with Phe and Tyr. Satisfactory resolution was obtained and amino acid peak widths at half height were only 1.6 s indicating efficient stacking. Calibration plots for Phe and Tyr in urine showed good linearity (R(2) > 0.96) in the concentration range 10-175 µM, and LODs for Phe and Tyr were 0.054 and 0.019 µM, respectively. RSDs for peak area and migration time for Phe and Tyr were below 7.5% and 0.75%, respectively.


Assuntos
Aminoácidos/urina , Eletroforese Capilar/métodos , Humanos , Concentração de Íons de Hidrogênio , Limite de Detecção , Sensibilidade e Especificidade
3.
Anal Bioanal Chem ; 400(1): 295-303, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21318246

RESUMO

In this work, the usefulness of capillary electrophoresis-electrospray ionization time-of-flight-mass spectrometry for the analysis of biopharmaceuticals was studied. Noncovalently bound capillary coatings consisting of Polybrene-poly(vinyl sulfonic acid) or Polybrene-dextran sulfate-Polybrene were used to minimize protein and peptide adsorption, and achieve good separation efficiencies. The potential of the capillary electrophoresis-mass spectrometry (CE-MS) system to characterize degradation products was investigated by analyzing samples of the drugs, recombinant human growth hormone (rhGH) and oxytocin, which had been subjected to prolonged storage, heat exposure, and/or different pH values. Modifications could be assigned based on accurate masses as obtained with time-of-flight-mass spectrometry (TOF-MS) and migration times with respect to the parent compound. For heat-exposed rhGH, oxidations, sulfonate formation, and deamidations were observed. Oxytocin showed strong deamidation (up to 40%) upon heat exposure at low pH, whereas at medium and high pH, mainly dimer (>10%) and trisulfide formation (6-7%) occurred. Recombinant human interferon-ß-1a (rhIFN-ß) was used to evaluate the capability of the CE-MS method to assess glycan heterogeneity of pharmaceutical proteins. Analysis of this N-glycosylated protein revealed a cluster of resolved peaks which appeared to be caused by at least ten glycoforms differing merely in sialic acid and hexose N-acetylhexosamine composition. Based on the relative peak area (assuming an equimolar response per glycoform), a quantitative profile could be derived with the disialytated biantennary glycoform as most abundant (52%). Such a profile may be useful for in-process and quality control of rhIFN-ß batches. It is concluded that the separation power provided by combined capillary electrophoresis and TOF-MS allows discrimination of highly related protein species.


Assuntos
Produtos Biológicos/análise , Eletroforese Capilar/métodos , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Hormônio do Crescimento/análise , Humanos , Interferon beta-1a , Interferon beta/análise , Ocitocina/análise , Proteínas Recombinantes/análise
4.
Anal Bioanal Chem ; 400(5): 1375-85, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21445660

RESUMO

A generic LC-MS/MS method was developed for the analysis of potentially genotoxic alkyl halides. A broad selection of alkyl halides were derivatized using 4-dimethylaminopyridine in acetonitrile. The reaction conditions for derivatization, i.e., solvent, reaction time, temperature and concentration of alkyl halide, active pharmaceutical ingredient (API), and reagent, were optimized for sensitivity and robustness. The interference of the matrix and the API and the presence of water on the derivatization reaction were investigated for a model drug product (paracetamol/caffeine tablets). Hydrophilic interaction liquid chromatography was used to allow a quantitative determination of the derivatives by tandem mass spectrometry. The derivatization reaction was shown to be selective for alkyl halides, although some reactivity was also observed for an aromatic sulfonate, which is also genotoxic. Even though differences in reaction efficiencies have been observed, the enhanced sensitivity obtained by the derivatization allows the majority of the alkyl halides to be detected by MS/MS at relevant levels for genotoxic impurity evaluation, i.e., 10 mg kg(-1). Another key advantage is that for the majority of derivatives, reagent-related fragments are produced, which allows low-level screening for alkyl halides. Highly specific MS detection can be performed using neutral loss and precursor ion scan experiments. The applicability of a generic screening method will make the genotox evaluation less dependent on the quality of assessments based on predictions only, and it will provide essential information during the development of new chemical entities. In addition to screening, target analysis in the low milligrams per kilogram range can be performed. A similar response of the derivatized compounds was obtained in the range of 1-100 mg kg(-1) with a reproducibility better than 10%, which is sufficient for the determination of alkyl halides in APIs and drug products.


Assuntos
Alcanos/química , Mutagênicos/química , Espectrometria de Massas em Tandem/métodos , 4-Aminopiridina/análogos & derivados , 4-Aminopiridina/química , Alcanos/análise , Alquilação , Cromatografia Líquida/métodos , Halogenação , Limite de Detecção , Mutagênicos/análise
5.
Anal Bioanal Chem ; 400(4): 1137-44, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21394451

RESUMO

Trehalose-6-phosphate (T6P) is an intermediate in the plant metabolic pathway that results in trehalose production. T6P has been shown to inhibit the sucrose nonfermenting-1-related protein kinase 1, which is a major regulator of metabolism. The quantitation of T6P has proven difficult due to the complexity of the plant matrix and the low abundance of T6P in plant tissues. The aim of this work was to develop a quantitation method for T6P present in Arabidopsis tissues, with capillary electrophoresis (CE) coupled to electrospray ionization-mass spectrometry (MS) with a sheath liquid (SL) interface. The CE-MS method was first optimized with respect to T6P signal intensity and separation of isomers by studying the composition of the background electrolyte (BGE) and SL. The use of triethylamine (TEA) in the BGE was favorable, providing separation of T6P from sucrose-6-phosphate and minimizing ionization suppression. Replacing ammonium acetate with TEA enhanced T6P signal intensities more than four times. The optimized method allowed quantification of T6P in plant extracts with good linearity (r(2) > 0.99) within a biologically relevant concentration range. The limit of quantification was 80 nM in Arabidopsis extracts, corresponding to 33 pmol/g plant fresh weight. The CE-MS method was applied to the determination of T6P in seedlings from wild type (WT) Arabidopsis and mutants lacking the trehalase AtTRE1, tre1-1, challenged with trehalose or sorbitol. T6P accumulation in tre1-1 plants grown on sorbitol was about twice the level of T6P found in WT. CE-MS is shown to be a fast and reliable technique to analyze phosphodisaccharides for seedling extracts. The low sample volume requirement of CE and its direct MS coupling makes it an attractive alternative for anion-exchange liquid chromatography-MS.


Assuntos
Eletroforese Capilar/métodos , Sementes/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Fosfatos Açúcares/análise , Trealose/análogos & derivados , Arabidopsis/química , Limite de Detecção , Redes e Vias Metabólicas , Extratos Vegetais/química , Trealose/análise , Trealose/biossíntese
6.
J Clin Virol ; 133: 104655, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33069846

RESUMO

Correct and reliable identification of SARS-CoV-2 in COVID-19 suspected patients is essential for diagnosis. Respiratory samples should always be tested with real-time PCR for SARS-CoV-2. In addition, blood samples have been tested, but without consistent results and therefore the added value of this sample type is unknown. The aim of this study was to determine the prevalence of SARS-CoV-2 by real-time PCR in blood samples obtained from PCR-proven COVID-19 patients and in addition to elaborate on the potential use of blood for diagnostics. In this single center study, blood samples drawn from patients at the emergency department with proven COVID-19 infection based on a positive SARS-CoV-2 PCR in respiratory samples were tested for the presence of SARS-CoV-2. Samples from 118 patients were selected, of which 102 could be included in the study (median age was 65 (IQR 10), 65.7 % men). In six (5.9 %) of the tested samples, SARS-CoV-2 was identified by real-time PCR. In conclusion, SARS-CoV-2 can be detected by real-time PCR in plasma samples from patients with proven COVID-19, but only in a minority of the patients. Plasma should therefore not be used as primary sample in an acute phase setting to identify SARS-CoV-2 infection. These findings are important to complete the knowledge on possible sample types to test to diagnose COVID-19.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19/sangue , Serviço Hospitalar de Emergência , SARS-CoV-2/isolamento & purificação , Idoso , Idoso de 80 Anos ou mais , COVID-19/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Prevalência , RNA Viral/sangue , SARS-CoV-2/genética , Viremia/diagnóstico
7.
J Chromatogr A ; 1204(2): 157-70, 2008 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-18565533

RESUMO

The developments in capillary isoelectric focusing (cIEF) over the period 2003-2007 are reviewed. With the focus on technological aspects, cIEF papers published in the fields of methodology, new techniques, detection, multidimensional systems, miniaturization and applications are summarized. The methodology section covers recent research in ampholytes composition, detergents and other additives, carrier ampholyte free cIEF, coatings and other capillary modifications. In the section on new systems adjustments to the technique (e.g. dynamic IEF), different applications of cIEF (e.g. as injection system) and new devices are reported. Systems focusing on whole column imaging, fluorescence and chemiluminescence detection and coupling to mass spectrometers are discussed in the section on detection. Interfacing cIEF with MS via RPLC systems and hyphenation of cIEF with capillary electrochromatography and other capillary electrophoresis modes are also summarized. Papers focusing on miniaturization are reviewed in the section on microfluidic devices. The section on applications will show analysis of biopharmaceutical compounds and isolated proteins for metabolomic studies. For the analysis of complex biological matrices, generally multidimensional systems are needed, which are mentioned throughout this review.


Assuntos
Eletroforese Capilar/métodos , Focalização Isoelétrica/métodos , Animais , Eletroforese Capilar/instrumentação , Eletroforese Capilar/tendências , Humanos , Focalização Isoelétrica/instrumentação , Focalização Isoelétrica/tendências , Técnicas Analíticas Microfluídicas
8.
J Chromatogr A ; 1159(1-2): 175-84, 2007 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-17588593

RESUMO

A generic approach has been developed for coupling capillary electrophoresis (CE) using non-volatile background electrolytes (BGEs) with mass spectrometry (MS) using a sheath liquid interface. CE-MS has been applied for basic and bi-functional compounds using a BGE consisting of 100 mM of TRIS adjusted to pH 2.5 using phosphoric acid. A liquid sheath effect is observed which may influence the CZE separation and hence may complicate the correlation between CE-UV and CE-MS methods. The influence of the liquid sheath effect on the migration behavior of basic pharmaceuticals has been studied by simulation experiments, in which the BGE outlet vial is replaced by sheath liquid in a CE-UV experiment. As a consequence of the liquid sheath effect, phosphate based BGEs can be used without significant loss of MS sensitivity compared to volatile BGEs. The use of buffer constituents such as TRIS can lead to lower detection limits as loss of MS sensitivity can be compensated by better CE performance. TRIS based BGEs permit relatively high injection amounts of about 100 pmol while maintaining high resolution. The ESI-MS parameters were optimized for a generic method with maximum sensitivity and stable operation, in which the composition of the sheath liquid and the position of the capillary were found to be important. Furthermore, the nebulizing pressure strongly influenced the separation efficiency. The system showed stable performance for several days and a reproducibility of about 15% RSD in peak area has been obtained. Nearly all test compounds used in this study could be analyzed with an MS detection limit of 0.05% measured in scan mode using extracted ion chromatograms. As a result, CE-MS was found to be a valuable analytical tool for pharmaceutical impurity profiling.


Assuntos
Contaminação de Medicamentos , Eletroforese Capilar/métodos , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrofotometria Ultravioleta/métodos , Soluções Tampão , Química Farmacêutica/métodos , Eletrólitos/química , Concentração de Íons de Hidrogênio , Preparações Farmacêuticas/química , Pressão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Volatilização
9.
Ned Tijdschr Geneeskd ; 161: D1202, 2017.
Artigo em Holandês | MEDLINE | ID: mdl-28401820

RESUMO

A 63-year-old male was seen at the rheumatology outpatient clinic because of a curved deformity of his left hand, with fixed flexion of the MCP joints and hyperextension of the PIP and DIP joints. This so-called striatal hand, a feature of Parkinson's disease, can easily be confused with rheumatoid arthritis or Dupuytren's contracture.


Assuntos
Doença de Parkinson/diagnóstico , Artrite Reumatoide/diagnóstico , Diagnóstico Diferencial , Contratura de Dupuytren/diagnóstico , Mãos/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular
10.
J Chromatogr B Analyt Technol Biomed Life Sci ; 834(1-2): 98-107, 2006 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-16527550

RESUMO

The characteristics of automated on-line solid phase extraction with liquid chromatography-mass spectrometry (SPE-LC-MS) are very amenable for flexibility and throughput in therapeutic drug monitoring (TDM). We demonstrate this concept of automated, on-line SPE-LC-MS for the analysis of clozapine and metabolites (desmethylclozapine and clozapine-N-oxide) in serum. Method development, optimisation and validation are described and a comparison with previously published methods for the determination of clozapine and metabolites in serum and plasma is made. Optimisation of chromatographic and SPE conditions for increased throughput resulted in SPE-LC-MS cycle times of only about 2.2 min, demonstrating the great potential of automated on-line SPE-LC-MS for TDM. The new method is shown to be clearly favourable, in particular in terms of ease of sample handling, throughput and detection limits. Recovery is essentially quantitative. Detection limits are at about 0.15-0.3 ng ml(-1), depending on the ionisation source used. Calibration follows a quadratic model for clozapine and its N-oxide and a linear model for the desmethyl metabolite (all cases: R > 0.99). Accuracy, evaluated at three concentration levels spanning the whole therapeutic range, shows that bias is less than 10%. Precision (intra - and inter assay) ranges from about 5% R.S.D. at the high end of the therapeutic range (700-1,000 ng ml(-1)) to about 20% R.S.D. (OECD defined limit) at the lower limit of quantitation ( approximately 50 ng ml(-1)). The lower limit of quantitation is well below the low end of the therapeutic range at 350 ng ml(-1).


Assuntos
Antipsicóticos/sangue , Cromatografia Líquida de Alta Pressão/métodos , Clozapina/sangue , Monitoramento de Medicamentos/métodos , Espectrometria de Massas/métodos , Humanos , Reprodutibilidade dos Testes
11.
J Chromatogr B Analyt Technol Biomed Life Sci ; 839(1-2): 68-73, 2006 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-16600700

RESUMO

This paper describes the on-line sample pretreatment and analysis of proteins and peptides with a poly(methylmethacrylate) (PMMA) microfluidic device (IonChip). This chip consists of two hyphenated electrophoresis channels with integrated conductivity detectors. The first channel can be used for sample preconcentration and sample clean-up, while in the second channel the selected compounds are separated. Isotachophoresis (ITP) combined with zone electrophoresis (CZE) was used to preconcentrate a myoglobin sample by a factor of about 65 before injection into the second dimension and to desalt a mixture of six proteins with 100 mM NaCl. However, ITP-CZE could not be used for the removal of two proteins from a protein/peptide sample since the protein zone in the ITP step was too small to remove certain compounds. Therefore, we used CZE-CZE for the removal of proteins from a protein/peptide mixture, thereby injecting only the peptides into the second CZE separation channel.


Assuntos
Eletroforese em Microchip/instrumentação , Eletroforese em Microchip/métodos , Proteínas/química , Proteínas/isolamento & purificação , Animais , Humanos , Sistemas On-Line
12.
Anal Chim Acta ; 940: 150-8, 2016 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-27662770

RESUMO

The sensitivity of coupled enantioselective capillary electrophoresis-mass spectrometry (CE-MS) of amino acids (AAs) is often hampered by the chiral selectors in the background electrolyte (BGE). A new method is presented in which the use of a chiral selector is circumvented by employing (+)-1-(9-fluorenyl)ethyl chloroformate (FLEC) as chiral AA derivatizing agent and ammonium perfluorooctanoate (APFO) as a volatile pseudostationary phase for separation of the formed diastereomers. Efficient AA derivatization with FLEC was completed within 10 min. Infusion experiments showed that the APFO concentration hardly affects the MS response of FLEC-AAs and presents significantly less ion suppression than equal concentrations of ammonium acetate. The effect of the pH and APFO concentration of the BGE and the capillary temperature were studied in order to achieve optimized enantioseparation. Optimization of CE-MS parameters, such as sheath-liquid composition and flow rate, ESI and MS settings was performed in order to prevent analyte fragmentation and achieve sensitive detection. Selective detection and quantification of 14 chiral proteinogenic AAs was achieved with chiral resolution between 1.2 and 8.6, and limits of detection ranging from 130 to 630 nM injected concentration. Aspartic acid and glutamic acid were detected, but not enantioseparated. The optimized method was applied to the analysis of chiral AAs in cerebrospinal fluid (CSF). Good linearity (R(2) > 0.99) and acceptable peak area and electrophoretic mobility repeatability (RSDs below 21% and 2.4%, respectively) were achieved for the chiral proteinogenic AAs, with sensitivity and chiral resolution mostly similar to obtained for standard solutions. Next to l-AAs, endogenous levels of d-serine and d-glutamine could be measured in CSF revealing enantiomeric ratios of 4.8%-8.0% and 0.34%-0.74%, respectively, and indicating the method's potential for the analysis of low concentrations of d-AAs in presence of abundant l-AAs.


Assuntos
Aminoácidos/líquido cefalorraquidiano , Eletroforese Capilar/métodos , Espectrometria de Massas/métodos , Estereoisomerismo
13.
Biosens Bioelectron ; 21(1): 49-59, 2005 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-15967350

RESUMO

The research on our flow-injection, label-free, non-faradaic impedimetric immunosensor for interferon-gamma (IFN-gamma) has been extended. The sensor is prepared by immobilization of anti-IFN-gamma antibodies on a self-assembled monolayer (SAM) of acetylcysteine, deposited on polycrystalline gold. A multi-frequency impedance method is described, which allows time-resolved measurement of Nyquist plots. To these plots, an equivalent circuit was fitted, which is discussed in terms of a two-layer structure (inner and outer layer) of the interfacial region. Because binding of IFN-gamma mainly causes a decrease of Q (a constant-phase element), this element is considered as the outer layer. Several aspects of the impedimetric sensor response are studied, including the dependence on detection frequency, target concentration and applied dc potential. For quantitative detection of IFN-gamma, an optimum of the signal-to-noise (S/N) ratio of the out-of-phase impedance component (Z'') was found at about 100 Hz. At a dc-potential of +0.2 V versus a saturated calomel reference electrode, the sensor response is higher than at 0.0 V. Logarithmic dose-response curves of IFN-gamma in the concentration range of 10(-18) to 10(-9) M were obtained using two procedures: by successive injections over a single electrode, and by using freshly prepared electrodes for each measurement. Using the latter method, the repeatability is impaired. The need for in situ complementary techniques for a correct interpretation of the studied parameters is discussed.


Assuntos
Técnicas Biossensoriais/instrumentação , Interferon gama/análise , Anticorpos/metabolismo , Sítios de Ligação de Anticorpos , Técnicas Biossensoriais/métodos , Cromatografia Líquida de Alta Pressão , Impedância Elétrica , Eletroquímica , Eletrodos , Interferon gama/imunologia , Interferon gama/metabolismo , Análise Espectral
14.
Biosens Bioelectron ; 21(3): 474-82, 2005 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-16076437

RESUMO

A study was initiated to investigate the use of surface plasmon resonance (SPR) for the detection in plasma of a high pI model protein, recombinant human interferon-gamma (IFN-gamma). Initially a number of self-assembled monolayers (SAMs) and hydrogel-derivatised SAM-coatings were characterised for the adsorptive and desorptive properties of plasma components. Next a monoclonal anti-IFN-gamma antibody, MD-2, was covalently attached to dextran-modified mercaptoundecanoic acid surfaces that performed best. On coatings consisting of carboxyl-modified dextran (CMD) a difference in interaction behaviour was observed when IFN-gamma was injected in either buffer or diluted plasma. During the injection of IFN-gamma in buffer, an acceleration of the interaction process was observed and the signal continued to increase after the injection plug had passed. Upon injection of diluted plasma spiked with IFN-gamma, the response increased without acceleration of the binding process. After the injection was finished, some of the bound material desorbed as expected, resulting in a signal decrease. On non-charged dextrans, the interaction between the antibody-modified surface and IFN-gamma in either plasma or buffer was similar. During sample injection the response increased with a binding rate depending on the concentration of IFN-gamma present in solution. When the injection was finished, some of the bound material was washed away from the surface and only a minor contribution of non-specific adsorbed plasma components was noticeable. From the coatings tested, the non-modified dextran-coated SPR sensor disks prove to be best suited for the detection of IFN-gamma in complex matrices like plasma. The interaction of IFN-gamma in both diluted plasma and buffer is comparable and concentrations of IFN-gamma of 250 ng ml-1 and higher can be detected in both buffer and 100x-diluted plasma. The non-specific adsorption of plasma components is low, whereas the specific IFN-gamma response is relatively high.


Assuntos
Anticorpos/química , Técnicas Biossensoriais/métodos , Análise Química do Sangue/métodos , Imunoensaio/métodos , Interferon gama/sangue , Ressonância de Plasmônio de Superfície/métodos , Animais , Anticorpos/imunologia , Técnicas Biossensoriais/instrumentação , Bovinos , Materiais Revestidos Biocompatíveis/química , Humanos , Imunoensaio/instrumentação , Interferon gama/imunologia , Ligação Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ressonância de Plasmônio de Superfície/instrumentação
15.
J Chromatogr A ; 1096(1-2): 165-76, 2005 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-16301078

RESUMO

In this paper, augmentation has been applied to data matrices, which originate from hyphenated methods that share the same mode of detection, but use different separation methods, HPLC-DAD and MEKC-DAD. A novel method, wavelength shift eigenstructure tracking (WET), has been proposed for the alignment between the wavelength scale of both detectors. WET proves to be suitable for the detection as well as correction of wavelength shift between both detectors. After correction of the wavelength scale, data obtained on both systems have been augmented and submitted to iterative target transformation factor analysis. Augmented curve resolution provides significantly better estimates of the chromatographic and electrophoretic profiles and spectra than the use of non-augmented curve resolution on HPLC and MEKC data separately. It is particularly useful when the pure fraction of a chromatographic peak is less than 0.10. Finally, the relative weight of MEKC versus HPLC in augmentation may be increased using intensity and noise normalisation. However, since noise normalisation and its accompanying decrease in signal-to-noise ratio leads to a loss of information, and, since intensity normalisation may cause a failure of the augmented curve resolution algorithm, benefits and drawbacks of normalisation should be weighed on a case-by-case basis.


Assuntos
Fracionamento Químico/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Capilar Eletrocinética Micelar/métodos , Algoritmos , Benzodiazepinas/isolamento & purificação , Análise Fatorial
16.
Anal Chim Acta ; 874: 75-83, 2015 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-25910449

RESUMO

A CE-MS method has been developed to detect trace levels of potentially genotoxic alkyl halides. After derivatization of the target components with 4-dimethylaminopyridine (DMAP) or butyl 1-(pyridinyl-4yl) piperidine 4-carboxylate (BPPC), the natively positively charged derivatives are pre-concentrated by applying electrokinetic injection and separated by a highly efficient CZE method using a background electrolyte (BGE) consisting of 100mM of TRIS adjusted to pH 2.5 with phosphoric acid. Using a sheath liquid interface, subsequent MS detection allows highly specific and sensitive analysis of alkyl halides. Conditions for electrokinetic injection were optimized to allow selective and effective injection. Injection of samples with low water content at 10 kV for 150 s using a high concentration of buffer in the BGE resulted in optimum sample stacking during injection and a highly efficient CE separation. At the sample pH applied, neutral and negatively charged components are shown to be selectively discarded, resulting in injection of positively charged ions only. The sample matrix influences the efficiency of the injection, but when using an internal standard, reproducibilities better than 10% RSD are obtained. Relative recoveries of the derivatives spiked to different types of model API between 85 and 115% demonstrate that the method can be applied for quantitative analysis. Detection limits of lower than 1 mg kg(-1) for the tested alkyl halides obtained in CE-MS at least equal the sensitivity obtained in LC-MS. The CE-MS method is a valuable alternative for the LC-MS method used for analysis of alkylation compounds.


Assuntos
Eletroforese Capilar/métodos , Hidrocarbonetos Bromados/análise , Espectrometria de Massas/métodos , Mutagênicos/análise , 4-Aminopiridina/análogos & derivados , 4-Aminopiridina/química , Alquilação , Cromatografia Líquida/métodos
17.
Neurology ; 34(11): 1507-9, 1984 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-6493504

RESUMO

The problems of long-term levodopa therapy tend to occur earlier if levodopa is combined from the start with a decarboxylase inhibitor. We conducted a retrospective study of 123 patients. Among patients treated with levodopa without a decarboxylase inhibitor, only 25% had response variations (end-of-dose deterioration, on-off response fluctuation) after 6 years of treatment. Among patients treated with both levodopa and a decarboxylase inhibitor, 90% showed response variations after 6 years of therapy.


Assuntos
Levodopa/administração & dosagem , Doença de Parkinson/tratamento farmacológico , Carboxiliases/antagonistas & inibidores , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
18.
Neurology ; 37(3): 485-7, 1987 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3822144

RESUMO

In 44 consecutive outpatients with idiopathic Parkinson's disease (PD) without levodopa substitution therapy, we tested spatial orientation. Spatial orientation was impaired on the rod orientation test in 43 patients, on the line orientation test in 7 patients, and on the facial recognition test in 17 patients. There was no correlation between severity of spatial disorientation and age, length of illness, verbal WAIS score, or severity of PD. Impairment of spatial orientation is part of PD even in mild cases.


Assuntos
Doença de Parkinson/psicologia , Percepção Espacial/fisiologia , Idoso , Idoso de 80 Anos ou mais , Percepção de Forma/fisiologia , Humanos , Pessoa de Meia-Idade , Orientação , Transtornos da Percepção/etiologia
19.
Neurology ; 38(11): 1802-3, 1988 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3185919

RESUMO

In 22 patients with idiopathic Parkinson's disease, we tested spatial orientation with the rod orientation test, before and after levodopa substitution therapy was started. In both situations an impairment of spatial orientation could be demonstrated: levodopa did not improve this impairment.


Assuntos
Levodopa/uso terapêutico , Doença de Parkinson/tratamento farmacológico , Idoso , Humanos , Pessoa de Meia-Idade , Doença de Parkinson/fisiopatologia , Testes Psicológicos , Comportamento Espacial
20.
J Chromatogr A ; 878(1): 27-33, 2000 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-10843542

RESUMO

Theoretical aspects of multiple solid-phase microextraction are described and the principle is illustrated with the extraction of lidocaine from aqueous solutions. With multiple extraction under non-equilibrium conditions considerably less time is required in order to obtain an extraction yield that is equal to that of one extraction at equilibrium. On the other side, the extraction yield can be increased if multiple extraction is performed with the same total time as is needed for one extraction at equilibrium time. The effect of multiple extraction is strongly dependent on the value of the partition constant and for practical use the length of the desorption time is important. A good agreement between theoretical and experimental data has been obtained. Chromatograms are presented showing the potential of multiple solid-phase microextraction.


Assuntos
Cromatografia Líquida/métodos