Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Comput Tomogr ; 18(2): 203-210, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38320905

RESUMO

BACKGROUND: We examined obstructive and nonobstructive plaque volumes in populations with subclinical and clinically manifested coronary artery disease (CAD) using quantitative computed tomography (QCT). METHODS: 855 participants with CAD (274 asymptomatic individuals, 254 acute chest pain patients without acute coronary syndrome (ACS), and 327 patients with ACS) underwent QCT of proximal coronary segments to assess participant-level plaque volumes of dense calcium, fibrous, fibrofatty, and necrotic core tissue. RESULTS: Nonobstructive (<50% stenosis) plaque volumes were greater than obstructive plaque volumes, irrespective of population (all p<0.0001): Asymptomatic individuals (mean (95% CI)): 218 [190-250] vs. 16 [12-22] mm3; acute chest pain patients without ACS: 300 [263-341] vs. 51 [41-62] mm3; patients with ACS: 370 [332-412] vs. 159 [139-182] mm3. After multivariable adjustment, nonobstructive fibrous and fibrofatty tissue volumes were greater in acute chest pain patients without ACS compared to asymptomatic individuals (fibrous tissue: 122 [107-139] vs. 175 [155-197] mm3, p<0.01; fibrofatty tissue: 44 [38-50] vs. 71 [63-80] mm3, p<0.01. Necrotic core tissue was greater in ACS patients (29 [26-33] mm3) compared to both asymptomatic individuals (15 [13-18] mm3, p<0.0001) and acute chest pain patients without ACS (21 [18-24] mm3, p<0.05). Nonobstructive dense calcium volumes did not differ between the three populations: 29 [24-36], 29 [23-35], and 41 [34-48] mm3, p>0.3 respectively. CONCLUSION: Nonobstructive CAD was the predominant contributor to total atherosclerotic plaque volume in both subclinical and clinically manifested CAD. Nonobstructive fibrous, fibrofatty and necrotic core tissue volumes increased with worsening clinical presentation, while nonobstructive dense calcium tissue volumes did not.


Assuntos
Síndrome Coronariana Aguda , Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Cálcio , Valor Preditivo dos Testes , Dor no Peito , Necrose , Angiografia Coronária/métodos
2.
Artigo em Inglês | MEDLINE | ID: mdl-33029616

RESUMO

AIMS: Assessment of haemodynamically significant coronary artery disease (CAD) using cardiovascular magnetic resonance (CMR) imaging perfusion or dynamic stress myocardial perfusion imaging by computed tomography (CT perfusion) may aid patient selection for invasive coronary angiography (ICA). We evaluated the diagnostic performance and incremental value of qualitative CMR perfusion and quantitative CT perfusion complementary to cardiac computed tomography angiography (CCTA) for the diagnosis of haemodynamically significant CAD using fractional flow reserve (FFR) and quantitative coronary angiography (QCA) as reference standard. METHODS AND RESULTS: CCTA, qualitative visual CMR perfusion, visual CT perfusion, and quantitative relative myocardial blood flow (CT-MBF) were performed in patients with stable angina pectoris. FFR was measured in coronary vessels with stenosis visually estimated between 30% and 90% diameter reduction on ICA. Haemodynamically significant CAD was defined as FFR <0.80, or QCA ≥80% in those cases where FFR could not be performed. A total of 218 vessels from 93 patients were assessed. An optimal cut-off of 0.72 for relative CT-MBF was determined. The diagnostic performances (area under the receiver-operating characteristics curves, 95% CI) of visual CMR perfusion (0.84, 0.77-0.90) and relative CT-MBF (0.86, 0.81-0.92) were comparable and outperformed visual CT perfusion (0.64, 0.57-0.71). In combination with CCTA ≥50%, CCTA + visual CMR perfusion (0.91, 0.86-0.96), CCTA + relative CT-MBF (0.92, 0.88-0.96), and CCTA + visual CT perfusion (0.82, 0.75-0.90) improved discrimination compared with CCTA alone (all P < 0.05). CONCLUSION: Visual CMR perfusion and relative CT-MBF outperformed visual CT perfusion and provided incremental discrimination compared with CCTA alone for the diagnosis of haemodynamically significant CAD.

3.
Eur Heart J Cardiovasc Imaging ; 20(8): 939-948, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30809640

RESUMO

AIMS: Accurate assessment of aortic dimensions can be achieved using contrast-enhanced computed tomography. The aim of this study was to define normal values and determinants of aortic dimensions throughout multiple key anatomical landmarks of the aorta in healthy individuals from the Copenhagen General Population Study. METHODS AND RESULTS: The study group consisted of 902 healthy subjects selected from 3000 adults undergoing cardiovascular thoracic and abdominal computed tomography-angiography (CTA), where systematic measurements of aortic dimensions were performed retrospectively. Individuals included were without any of the following predefined cardiovascular risk factors: (i) self-reported angina pectoris; (ii) hypertension; (iii) hypercholesterolaemia; (iv) taking cardiovascular prescribed medication including diuretics, statins, or aspirin; (v) overweight (defined as body mass index ≥30 kg/m2); (vi) diabetes mellitus (self-reported or blood glucose >8 mmol/L); and (vii) chronic obstructive pulmonary disease. Maximal aortic diameters were measured at seven aortic regions: sinuses of Valsalva, sinotubular junction, ascending aorta, mid-descending aorta, abdominal aorta at the diaphragm, abdominal aorta at the coeliac trunk, and infrarenal abdominal aorta. Median age was 52 years, and 396 (40%) were men. Men had significantly larger aortic diameters at all levels compared with women (P < 0.001). Multivariable analysis revealed that sex, age, and body surface area were associated with increasing aortic dimensions. CONCLUSION: Normal values of maximal aortic dimensions at key aortic anatomical locations by contrast-enhanced CTA have been defined. Age, sex, and body surface area were significantly associated with these measures at all levels of aorta. Aortic dimensions follow an almost identical pattern throughout the vessel regardless of sex.


Assuntos
Aorta/anatomia & histologia , Aorta/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Adulto , Pontos de Referência Anatômicos , Meios de Contraste , Estudos Transversais , Dinamarca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Valores de Referência , Estudos Retrospectivos , Inquéritos e Questionários , Ácidos Tri-Iodobenzoicos
4.
Eur Heart J Cardiovasc Imaging ; 20(11): 1221-1230, 2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30325406

RESUMO

AIMS: Quantitative computed tomography (QCT) allows assessment of morphological features of coronary atherosclerosis. We aimed to test the hypothesis that clinical patient presentation is associated with distinct morphological features of coronary atherosclerosis. METHODS AND RESULTS: A total of 1652 participants, representing a spectrum of clinical risk profiles [787 asymptomatic individuals from the general population, 468 patients with acute chest pain without acute coronary syndrome (ACS), and 397 patients with acute chest pain and ACS], underwent multidetector computed tomography. Of these, 274 asymptomatic individuals, 254 patients with acute chest pain without ACS, and 327 patients with acute chest pain and ACS underwent QCT to assess coronary plaque volumes and proportions of dense calcium (DC), fibrous, fibro fatty (FF), and necrotic core (NC) tissue. Furthermore, the presence of vulnerable plaques, defined by plaque volume and tissue composition, was examined. Coronary plaque volume increased significantly with worsening clinical risk profile [geometric mean (95% confidence interval): 148 (129-166) mm3, 257 (224-295) mm3, and 407 (363-457) mm3, respectively, P < 0.001]. Plaque composition differed significantly across cohorts, P < 0.0001. The proportion of DC decreased, whereas FF and NC increased with worsening clinical risk profile (mean proportions DC: 33%, 23%, 23%; FF: 50%, 61%, 57%; and NC: 17%, 17%, 20%, respectively). Significant differences in plaque composition persisted after multivariable adjustment for age, gender, body surface area, hypertension, statin use at baseline, diabetes, smoking, family history of ischaemic heart disease, total plaque volume, and tube voltage, P < 0.01. CONCLUSION: Coronary atherosclerotic plaque volume and composition are strongly associated to clinical presentation.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Placa Aterosclerótica/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Dor no Peito/diagnóstico por imagem , Meios de Contraste , Dinamarca , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Ácidos Tri-Iodobenzoicos
5.
Circ Cardiovasc Imaging ; 12(9): e009476, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31522551

RESUMO

BACKGROUND: Diabetes mellitus (DM) is associated with increased risk of cardiovascular disease. Detection of early cardiac changes before manifest disease develops is important. We investigated early alterations in cardiac structure and function associated with DM using cardiovascular magnetic resonance imaging. METHODS: Participants from the UK Biobank Cardiovascular Magnetic Resonance Substudy, a community cohort study, without known cardiovascular disease and left ventricular ejection fraction ≥50% were included. Multivariable linear regression models were performed. The investigators were blinded to DM status. RESULTS: A total of 3984 individuals, 45% men, (mean [SD]) age 61.3 (7.5) years, hereof 143 individuals (3.6%) with DM. There was no difference in left ventricular (LV) ejection fraction (DM versus no DM; coefficient [95% CI]: -0.86% [-1.8 to 0.5]; P=0.065), LV mass (-0.13 g/m2 [-1.6 to 1.3], P=0.86), or right ventricular ejection fraction (-0.23% [-1.2 to 0.8], P=0.65). However, both LV and right ventricular volumes were significantly smaller in DM, (LV end-diastolic volume/m2: -3.46 mL/m2 [-5.8 to -1.2], P=0.003, right ventricular end-diastolic volume/m2: -4.2 mL/m2 [-6.8 to -1.7], P=0.001, LV stroke volume/m2: -3.0 mL/m2 [-4.5 to -1.5], P<0.001; right ventricular stroke volume/m2: -3.8 mL/m2 [-6.5 to -1.1], P=0.005), LV mass/volume: 0.026 (0.01 to 0.04) g/mL, P=0.006. Both left atrial and right atrial emptying fraction were lower in DM (right atrial emptying fraction: -6.2% [-10.2 to -2.1], P=0.003; left atrial emptying fraction:-3.5% [-6.9 to -0.1], P=0.043). LV global circumferential strain was impaired in DM (coefficient [95% CI]: 0.38% [0.01 to 0.7], P=0.045). CONCLUSIONS: In a low-risk general population without known cardiovascular disease and with preserved LV ejection fraction, DM is associated with early changes in all 4 cardiac chambers. These findings suggest that diabetic cardiomyopathy is not a regional condition of the LV but affects the heart globally.


Assuntos
Cardiomiopatias Diabéticas/diagnóstico por imagem , Cardiomiopatias Diabéticas/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Idoso , Comorbidade , Feminino , Testes de Função Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Reino Unido
6.
PLoS One ; 13(12): e0207980, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30550593

RESUMO

PURPOSE: Quantitative computed tomography (QCT) provides important prognostic information of coronary atherosclerosis. We investigated intraobserver and interobserver QCT reproducibility in asymptomatic individuals, patients with acute chest pain without acute coronary syndrome (ACS), and patients with acute chest pain and ACS. METHODS: Fifty patients from each cohort, scanned between 01/02/2010-14/11/2013 and matched according to age and gender, were retrospectively assessed for inclusion. Patients with no coronary artery disease, previous coronary artery bypass graft surgery, and poor image quality were excluded. Coronary atherosclerosis was measured semi-automatically by 2 readers. Reproducibility of minimal lumen area (MLA), minimal lumen diameter (MLD), area stenosis, diameter stenosis, vessel remodeling, plaque eccentricity, plaque burden, and plaque volumes was assessed using concordance correlation coefficient (CCC), Bland-Altman, coefficient of variation, and Cohen's kappa. RESULTS: A total of 84 patients (63 matched) were included. Intraobserver and interobserver reproducibility estimates were acceptable for MLA (CCC = 0.94 and CCC = 0.91, respectively), MLD (CCC = 0.92 and CCC = 0.86, respectively), plaque burden (CCC = 0.86 and CCC = 0.80, respectively), and plaque volume (CCC = 0.97 and CCC = 0.95, respectively). QCT detected area and diameter stenosis ≥50%, positive remodeling, and eccentric plaque with moderate-good intraobserver and interobserver reproducibility (kappa: 0.64-0.66, 0.69-0.76, 0.46-0.48, and 0.41-0.62, respectively). Reproducibility of plaque composition decreased with decreasing plaque density (intraobserver and interobserver CCC for dense calcium (>0.99; 0.98), fibrotic (0.96; 0.93), fibro-fatty (0.95; 0.91), and necrotic core tissue (0.89; 0.84). Reproducibility generally decreased with worsening clinical risk profile. CONCLUSIONS: Semi-automated QCT of coronary plaque morphology is reproducible, albeit with some decline in reproducibility with worsening patient risk profile.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Dor no Peito/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/complicações , Doença Aguda , Idoso , Doenças Assintomáticas , Dor no Peito/etiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Prognóstico , Ensaios Clínicos Controlados Aleatórios como Assunto , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
EuroIntervention ; 13(9): e1067-e1075, 2017 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-28741579

RESUMO

AIMS: This study aimed to assess the potential relationship between subclinical leaflet thickening and stent frame geometry in patients who underwent aortic valve replacement with a self-expanding transcatheter heart valve (THV). METHODS AND RESULTS: Seventy-five patients with a self-expanding THV were studied with 4D-computed tomography and analysed for leaflet thickening. There was no difference in THV size, overall THV expansion, eccentricity or implantation depth between patients with and those without leaflet thickening. Moderate-to-severe regional THV underexpansion (≤90°) more frequently occurred at the non-coronary and right coronary cusps with a significantly higher incidence of leaflet thickening than in cases of full regional THV expansion (24% vs. 3%, p<0.01). Regional THV underexpansion at the inflow level more often translated into the same issue at the valvular level in THV with intra-annular as compared to supra-annular valve position (54% vs. 17%; p=0.04). In case of post-dilatation, regional THV underexpansion occurred less frequently as compared to THV that were not post-dilated (18% vs. 43%, p=0.028). A similar but non-significant trend was found for leaflet thickening. CONCLUSIONS: Regional THV stent frame underexpansion is associated with an increased risk of leaflet thickening. Post-dilatation of self-expanding THV as well as a supra-annular valve position seem to reduce the occurrence of this phenomenon.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/patologia , Estenose da Valva Aórtica/patologia , Feminino , Tomografia Computadorizada Quadridimensional , Humanos , Masculino , Estudos Retrospectivos
9.
Int J Cardiovasc Imaging ; 32(10): 1555-66, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27378095

RESUMO

To evaluate the interobserver agreement of visual coronary plaque characteristics by 320-slice multidetector computed tomography (MDCT) in three populations with low, intermediate and high CAD prevalence and to identify determinants for the reproducible assessment of these plaque characteristics. 150 patients, 50 asymptomatic subjects from the general population (low CAD prevalence), 50 symptomatic non-acute coronary syndrome (non-ACS) patients (intermediate CAD prevalence), and 50 ACS patients (high CAD prevalence), matched according to age and gender, were retrospectively enrolled. All coronary segments were evaluated for overall image quality, evaluability, presence of CAD, coronary stenosis, plaque composition, plaque focality, and spotty calcification by four readers. Interobserver agreement was assessed using Fleiss' Kappa (κ) and intra-class correlation (ICC). Widely used clinical parameters (overall scan quality, presence of CAD, and determination of coronary stenosis) showed good agreement among the four readers, (ICC = 0.66, κ = 0.73, ICC = 0.74, respectively). When accounting for heart rate, body mass index, plaque location, and coronary stenosis above/below 50 %, interobserver agreement for plaque composition, presence of CAD, and coronary stenosis improved to either good or excellent, (κ = 0.61, κ = 0.81, ICC = 0.78, respectively). Spotty calcification was the least reproducible parameter investigated (κ = 0.33). Across subpopulations, reproducibility of coronary plaque characteristics generally decreased with increasing CAD prevalence except for plaque composition, (limits of agreement: ±2.03, ±1.96, ±1.79 for low, intermediate and high CAD prevalence, respectively). 320-slice MDCT can be used to assess coronary plaque characteristics, except for spotty calcification. Reproducibility estimates are influenced by heart rate, body size, plaque location, and degree of luminal stenosis.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/epidemiologia , Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Idoso , Dinamarca/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Placa Aterosclerótica , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA