Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(10): 1867-1874, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37134309

RESUMO

OBJECTIVES: The TensorTip™ MTX is a non-invasive device designed to determine several physiological parameters with additional analysis of haemoglobin, haematocrit and blood gas analysis by interpreting blood diffusion colour of the finger skin based on spectral analysis. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in a clinical setting in comparison with routine analysis of blood samples. METHODS: Forty-six patients, scheduled for elective surgery, were enrolled in this study. Placement of an arterial catheter had to be part of the standard of care. Measurements were performed during the perioperative period. The measurements obtained with the TensorTip MTX were compared with the results of routine analysis of the blood samples as a reference using correlation, Bland-Altman analysis and mountain plots. RESULTS: No significant correlation was present in the measurements. Measurement of haemoglobin with the TensorTip MTX had a mean bias of 0.4 mmol/L, haematocrit's bias was 3.0 %. Bias of partial pressure of carbon dioxide and oxygen was 3.6 and 66.6 mmHg, respectively. Calculated percentage errors were 48.2 , 48.9, 39.9 and 109.0 %. Proportional bias was present in all Bland-Altman analyses. Less than 95 % of the differences fell within the pre-set limits of allowable error. CONCLUSIONS: Non-invasive blood content analysis with the TensorTip MTX device is not equivalent to and did not correlate sufficiently with conventional laboratory analysis. None of the parameters measured showed results within the limits of allowable error. Therefore, the use of the TensorTip MTX is not recommended for perioperative care.


Assuntos
Testes Hematológicos , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Gasometria , Oxigênio , Hemoglobinas
2.
Cardiol Res ; 13(6): 372-379, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36660063

RESUMO

Background: The noninvasive TensorTip™ MTX measures blood pressure by interpreting blood diffusion color of the finger skin. In addition to blood pressure, the device is able to measure various vital signs: heart rate, oxygen saturation, stroke volume, and cardiac output. Studies about accuracy and precision thus far available have only been conducted by the manufacturer. The aim of our study was to investigate the accuracy and precision of the TensorTip MTX in comparison to invasive radial artery blood pressure values. Methods: Forty-one patients scheduled for elective surgery were enrolled in this study. Placement of the arterial catheter had to be part of the standard of care. Once hemodynamic stable conditions were achieved, blood pressure was measured. Three measurements with the TensorTip MTX were averaged and compared with one invasive blood pressure measurement using Bland-Altman plot and error grid analysis. Results: Systolic, diastolic, and mean blood pressure had a bias of respectively 6.2, -6.9 and 4.4 mm Hg. Corresponding standard deviation were respectively 30.1, 17.0 and 22.2. Calculated percentage errors were 47.6%, 52.9% and 52.3%. Proportional bias was present in all Bland-Altman analyses. Error grid analysis showed 61.0% of systolic blood pressure measurements, and 46.3% of mean blood pressure measurements were in the clinical acceptable zone. Conclusions: The TensorTip MTX was not able to reliably measure blood pressure compared to blood pressure obtained with an arterial catheter and therefore, the measurement performance is not clinically acceptable. Moreover, a high malfunction rate makes the device unsuitable for use in perioperative period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA