Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Prostate ; 84(9): 842-849, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38571454

RESUMO

PURPOSE: Prostate specific antigen (PSA) testing is a low-cost screening method for prostate cancer (PCa). However, its accuracy is limited. While progress is being made using medical imaging for PCa screening, PSA testing can still be improved as an easily accessible first step in the screening process. We aimed to develop and validate a new model by further personalizing the analysis of PSA with demographic, medical history, lifestyle parameters, and digital rectal examination (DRE) results. METHODS: Using data from 34,224 patients in the screening arm of the PLCO trial (22,188 for the training set and 12,036 for the validation set), we applied a gradient-boosting model whose features (Model 1) were one PSA value and the personal variables available in the PLCO trial except those that signaled an ex-ante assumption of PCa. A second algorithm (Model 2) included a DRE result. The primary outcome was the occurrence of PCa, while the aggressiveness of PCa was a secondary outcome. ROC analyses were used to compare both models to other initial screening tests. RESULTS: The areas under the curve (AUC) for Model 2 was 0.894 overall and 0.908 for patients with a suspicious DRE, compared to 0.808 for PSA for patients with a suspicious DRE. The AUC for Model 1 was 0.814 compared to 0.821 for PSA. Model 2 predicted 58% more high-risk PCa than PSA ≥4 combined with an abnormal DRE and had a positive predictive value of 74.7% (vs. 50.6%). CONCLUSION: Personalizing the interpretation of PSA values and DRE results with a gradient-boosting model showed promising results as a potential novel, low-cost method for the initial screening of PCa. The importance of DRE, when included in such a model, was also highlighted.


Assuntos
Algoritmos , Exame Retal Digital , Detecção Precoce de Câncer , Aprendizado de Máquina , Antígeno Prostático Específico , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/sangue , Antígeno Prostático Específico/sangue , Detecção Precoce de Câncer/métodos , Pessoa de Meia-Idade , Idoso , Exame Retal Digital/métodos , Programas de Rastreamento/métodos
2.
Biopreserv Biobank ; 14(1): 29-38, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26812548

RESUMO

Collection of human whole blood for genomic DNA extraction is part of numerous clinical studies. Since DNA extraction cannot always be performed at the time of sample collection, whole blood samples may be stored for years before being processed. The use of appropriate storage conditions is then critical to obtain DNA in sufficient quantity and of adequate quality in order to obtain reliable results from the subsequent molecular biological analyses. In this study, EDTA whole blood samples were collected from 8 healthy volunteers, and different durations (up to 1 year) and temperatures (room temperature, 4°C, -20°C, and -80°C) of storage were compared. The effect of the addition of a DNA preservative agent was also assessed before and after storage. DNA concentrations measured by UV spectrophotometry and spectrofluorometry were used to calculate DNA extraction yields and double-strand DNA ratios. DNA integrity was controlled by agarose gel electrophoresis and long-range polymerase chain reaction. The impact of storage conditions on DNA methylation was also evaluated. Results showed that certain storage conditions have a significant impact on the DNA extraction yield but little or no effect on DNA integrity and methylation. Storage of EDTA blood at -80°C guarantees high-quality DNA with a good yield. Higher DNA extraction yields were obtained with the addition of a DNA preservative agent before thawing EDTA blood stored at -20°C or -80°C. Long-term storage at room temperature in the presence of a DNA preservative agent also appeared to be a reliable procedure.


Assuntos
Preservação de Sangue/efeitos adversos , Metilação de DNA/genética , DNA/genética , Humanos
3.
Biopreserv Biobank ; 13(2): 79-93, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25880472

RESUMO

BACKGROUND: This is the third in a series of publications presenting formal method validation for biospecimen processing in the context of accreditation in laboratories and biobanks. We report here optimization of a stool processing protocol validated for fitness-for-purpose in terms of downstream DNA-based analyses. METHODS: Stool collection was initially optimized in terms of sample input quantity and supernatant volume using canine stool. Three DNA extraction methods (PerkinElmer MSM I®, Norgen Biotek All-In-One®, MoBio PowerMag®) and six collection container types were evaluated with human stool in terms of DNA quantity and quality, DNA yield, and its reproducibility by spectrophotometry, spectrofluorometry, and quantitative PCR, DNA purity, SPUD assay, and 16S rRNA gene sequence-based taxonomic signatures. RESULTS: The optimal MSM I protocol involves a 0.2 g stool sample and 1000 µL supernatant. The MSM I extraction was superior in terms of DNA quantity and quality when compared to the other two methods tested. Optimal results were obtained with plain Sarstedt tubes (without stabilizer, requiring immediate freezing and storage at -20°C or -80°C) and Genotek tubes (with stabilizer and RT storage) in terms of DNA yields (total, human, bacterial, and double-stranded) according to spectrophotometry and spectrofluorometry, with low yield variability and good DNA purity. No inhibitors were identified at 25 ng/µL. The protocol was reproducible in terms of DNA yield among different stool aliquots. CONCLUSIONS: We validated a stool collection method suitable for downstream DNA metagenomic analysis. DNA extraction with the MSM I method using Genotek tubes was considered optimal, with simple logistics in terms of collection and shipment and offers the possibility of automation. Laboratories and biobanks should ensure protocol conditions are systematically recorded in the scope of accreditation.


Assuntos
DNA/análise , Fezes/química , Manejo de Espécimes/métodos , Animais , Cães , Fezes/microbiologia , Humanos , Metagenoma , Manejo de Espécimes/instrumentação , Espectrofotometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA