Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Anal Chem ; 95(26): 9863-9871, 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37262129

RESUMO

This study aims to investigate the potential benefits of adapting the ablating grid in two-dimensional (2D) and three-dimensional (3D) laser ablation inductively coupled plasma mass spectrometry in a single pulse mapping mode. The goals include enhancing the accuracy of surface sampling of element distributions, improving the control of depth-related sampling, smoothing the post-ablation surface for layer-by-layer sampling, and increasing the image quality. To emulate the capabilities of currently unavailable laser ablation stages, a computational approach using geometrical modeling was employed to compound square or round experimentally obtained 3D crater profiles on variable orthogonal or hexagonal ablation grids. These grids were optimized by minimizing surface roughness as a function of average ablation depth, followed by simulating the post-ablation surface and related image quality. An online application (https://laicpms-apps.ki.si/webapps/home/) is available for users to virtually experiment with contracting/expanding orthogonal and hexagonal ablation grids for generic 3D super-Gaussian laser crater profiles, allowing for exploration of the resulting post-ablation surface layer roughness and depth.

2.
Anal Chem ; 95(19): 7804-7812, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37122168

RESUMO

Laser ablation (LA) in combination with inductively coupled plasma time-of-flight mass spectrometry (ICP-TOFMS) enables monitoring of elements from the entire mass range for every pixel, regardless of the isotopes of interest for a certain application. This provides nontargeted multi-element (bio-)imaging capabilities and the unique possibility to screen for elements that were initially not expected in the sample. Quantification of a large range of elements is limited as the preparation of highly multiplexed calibration standards for bioimaging applications by LA-ICP-(TOF)MS is challenging. In this study, we have developed a workflow for semiquantitative analysis by LA-ICP-TOFMS based on multi-element gelatin micro-droplet standards. The presented approach is intended for the mapping of biological samples due to the requirement of matrix-matched standards for accurate quantification in LA-ICPMS, a prerequisite that is given by the use of gelatin-based standards. A library of response factors was constructed based on 72 elements for the semiquantitative calculations. The presented method was evaluated in two stages: (i) on gelatin samples with known elemental concentrations and (ii) on real-world samples that included prime examples of bioimaging (mouse spleen and tumor tissue). The developed semiquantification approach was based on 10 elements as calibration standards and provided the determination of 136 nuclides of 63 elements, with errors below 25%, and for half of the nuclides, below 10%. A web application for quantification and semiquantification of LA-ICP(-TOF)MS data was developed, and a detailed description is presented to easily allow others to use the presented method.


Assuntos
Gelatina , Terapia a Laser , Camundongos , Animais , Espectrometria de Massas/métodos , Análise Espectral , Alimentos
3.
Anal Bioanal Chem ; 415(2): 317-326, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36348039

RESUMO

This work describes the intricacies of the determination of the trimethylselenonium ion (TMSe) in human urine via high-performance liquid chromatography-hydride generation-atomic fluorescence spectrometry (HPLC-HG-AFS). By definition, this technique requires that the separated TMSe can be online converted into a volatile compound. Literature data for the determination of TMSe via the hydride generation technique are contradictory; i.e., some authors claim that direct formation of volatile compounds is possible under reduction with NaBH4, whereas others reported that a digestion step is mandatory prior to conversion. We studied and optimized the conditions for online conversion by varying the mobile phase composition (pyridine, phosphate, and acetate), testing different reaction coils, and optimizing the hydride generation conditions, although technically no hydride (H2Se) is formed but a dimethylselenide (DMSe). The optimized conditions were used for the analysis of 64 urine samples of 16 (unexposed) volunteers and the determination of low amounts of TMSe (LOD = 0.2 ng mL-1). Total (specific gravity-corrected) selenium concentrations in the urine samples ranged from 7.9 ± 0.7 to 29.7 ± 5.0 ng mL-1 for individual volunteers. Four volunteers were characterized as TMSe producers (hINMT genotype GA) and 12 were non-producers (hINMT genotype GG). Urine of TMSe producers contained 2.5 ± 1.7 ng mL-1 of TMSe, compared to 0.2 ± 0.2 ng mL-1 for non-producers.


Assuntos
Compostos de Selênio , Selênio , Humanos , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Fluorescência , Selênio/urina
4.
New Phytol ; 226(2): 492-506, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31898330

RESUMO

Lead (Pb) ranks among the most problematic environmental pollutants. Background contamination of soils is nearly ubiquitous, yet plant Pb accumulation is barely understood. In a survey covering 165 European populations of the metallophyte Arabidopsis halleri, several field samples had indicated Pb hyperaccumulation, offering a chance to dissect plant Pb accumulation. Accumulation of Pb was analysed in A. halleri individuals from contrasting habitats under controlled conditions to rule out aerial deposition as a source of apparent Pb accumulation. Several elemental imaging techniques were employed to study the spatial distribution and ligand environment of Pb. Regardless of genetic background, A. halleri individuals showed higher shoot Pb accumulation than A. thaliana. However, dose-response curves revealed indicator rather than hyperaccumulator behaviour. Xylem sap data and elemental imaging unequivocally demonstrated the in planta mobility of Pb. Highest Pb concentrations were found in epidermal and vascular tissues. Distribution of Pb was distinct from that of the hyperaccumulated metal zinc. Most Pb was bound by oxygen ligands in bidentate coordination. A. halleri accumulates Pb whenever soil conditions render Pb phytoavailable. Considerable Pb accumulation under such circumstances, even in leaves of A. thaliana, strongly suggests that Pb can enter food webs and may pose a food safety risk.


Assuntos
Proteínas de Arabidopsis , Arabidopsis , Arabidopsis/metabolismo , Proteínas de Arabidopsis/metabolismo , Cádmio/metabolismo , Regulação da Expressão Gênica de Plantas , Chumbo , Folhas de Planta/metabolismo , Zinco/metabolismo
5.
Anal Chem ; 91(9): 6200-6205, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-30929434

RESUMO

In the past decade, the development of single particle-inductively coupled plasma mass spectrometry (SP-ICPMS) has revolutionized the field of nanometallomics. Besides differentiation between dissolved and particulate metal signals, SP-ICPMS can quantify the nanoparticle (NP) number concentration and size. Because SP-ICPMS is limited to characterization of NPs in solution, we show how solid sampling by laser ablation (LA) adds spatial-resolution characteristics for localized NP analysis in biomaterials. Using custom-made gelatin standards doped with dissolved gold and commercial or synthesized gold nanoparticles, LA-SP-ICPMS conditions such as laser fluence, beam size, and dwell time were optimized for NP analysis to minimize NP degradation, peak overlap, and interferences from dissolved gold. A data-processing algorithm to retrieve the NP number concentration and size was developed for this purpose. As a proof-of-concept, a sunflower-root-sample cross-section, originating from a sunflower plant exposed to gold NPs, was successfully imaged using the optimized LA-SP-ICPMS conditions for localized NP characterization.


Assuntos
Materiais Biocompatíveis/química , Ouro/análise , Nanopartículas Metálicas/análise , Terapia a Laser , Espectrometria de Massas
6.
Anal Chem ; 90(9): 5916-5922, 2018 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-29606003

RESUMO

This work focuses on the structural similarity (SSIM) index as a tool for optimization of the perceived visual image quality obtainable by continuous scanning 2D LA-ICPMS bioimaging, but also other mass spec imaging techniques may benefit from this approach. This index quantifies the differences between a distorted image and a reference image based on parameters associated with luminance, contrast, and noise. Since reference images are not normally available, a protocol was developed to virtually apply distortion-related information introduced by the LA-ICPMS imaging system to a reference image of one's choice. Distortion-related information in the form of blur and noise was experimentally retrieved from line scans across a laser milled knife edge on custom-prepared gelatin standards (mimicking proteinaceous biomatrixes). Distorted images were generated via computational procedures developed earlier, warranting objective image quality assessment via the SSIM indices. We illustrate the potential of this approach for image quality optimization for a suite of LA-ICPMS imaging conditions.


Assuntos
Cintilografia , Animais , Humanos , Terapia a Laser , Espectrometria de Massas
7.
Anal Chem ; 90(4): 2896-2901, 2018 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-29376317

RESUMO

Pulsed laser ablation (LA) devices in laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) imaging have become very advanced, delivering laser pulses with high temporal accuracy and stable energy density. However, unintentional imaging artifacts may be generated in 2D element maps when the LA repetition rate and the data acquisition parameters of ICPMS instruments with a sequential mass spectrometer (i.e., quadrupole filter or sector-field mass spectrometer) are desynchronized. This may potentially lead to interference patterns, visible as ripples in elemental images, and thus, compromised image quality. This paper describes the background of aliasing in continuous scanning mode through simulation experiments and ways to modulate the effect. The existence of this image degradation source is demonstrated experimentally via real-life imaging of a homogeneous glass standard.

8.
Analyst ; 142(18): 3356-3359, 2017 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-28832035

RESUMO

Highly homogeneous multi-element gelatin calibration standards were fabricated for quantitative LA-ICP-MS bioimaging. Heterogeneity issues caused by the so-called "coffee-stain" and/or "Marangoni" effects were found to be element-dependent but could be circumvented by careful selection of drying/setting conditions. A micro-homogeneity test was developed for certification of the standards.

9.
Anal Chem ; 87(12): 6125-32, 2015 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-25975805

RESUMO

In this work, pre- and postacquisition procedures for enhancing the lateral resolution of laser ablation-inductively coupled plasma mass spectrometry (LA-ICPMS) in two- and three-dimensional (2D, 3D) nuclide distribution mapping beyond the laser beam waist are described. 2D images were constructed by projecting a rectangular grid of discrete LA positions, arranged at interspacings smaller than the dimensions of the laser beam waist, onto the sample surface, thus oversampling the region of interest and producing a 2D image convolved in the spatial domain. The pulse response peaks of a low-dispersion LA cell were isolated via signal deconvolution of the transient mass analyzer response. A 3D stack of 2D images was deconvolved by an iterative Richardson-Lucy algorithm with Total Variance regularization, enabling submicrometer image fidelity, demonstrated in the analysis of trace level features in corroded glass. A point spread function (PSF) could be derived from topography maps of single pulse craters from atomic force microscopy. This experimental PSF allows the approach to take into account the laser beam shape, beam aberrations, and the laser-solid interaction, which in turn enhances the spatial resolution of the reconstructed volume.

10.
Anal Bioanal Chem ; 407(12): 3377-91, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25716469

RESUMO

In general the analysis of archeological glass represents a challenge for a wide variety of objects because of the presence of physical and/or chemical damage on the surface of the artifact, also known as weathering or corrosion. To retrieve accurate bulk elemental information by laser ablation-inductively coupled plasma-mass spectrometry (ICP-MS), the original, pristine glass needs to be "reached", thereby penetrating the alteration layer which is often more than 10 µm thick. To study this alteration layer the laser was operated in the drilling mode, either with a low (1 Hz) or a high (10 Hz) pulse repetition rate for a period of 50 s yielding detailed spatial information for ca. 20 elements over a shallow depth (ca. 5 µm) or less-detailed spatial information for 50-60 elements over a greater depth (ca. 50 µm). Quantitative elemental depth profiles (in wt%) were obtained with the so-called sum normalization calibration protocol, based on summation of the elements as their oxides to 100 wt%. We were able to associate the increase of SiO2 (in wt%) in the alteration layer to the volumetric mass density change in the glass as a result of depletion of Na2O and K2O. Also the interaction of the number of laser shots with the alteration layer is shown experimentally via depth measurements using profilometry. Chemical and physical changes in four ancient glass artifacts, directly and indirectly measureable by laser drilling, were studied as a function of internal and external factors such as age, composition, and exposure conditions.

11.
Plant Cell Environ ; 37(6): 1299-320, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24237383

RESUMO

Cadmium and zinc share many similar physiochemical properties, but their compartmentation, complexation and impact on other mineral element distribution in plant tissues may drastically differ. In this study, we address the impact of 10 µm Cd or 50 µm Zn treatments on ion distribution in leaves of a metallicolous population of the non-hyperaccumulating species Zygophyllum fabago at tissue and cell level, and the consequences on the plant response through a combined physiological, proteomic and metabolite approach. Micro-proton-induced X-ray emission and laser ablation inductively coupled mass spectrometry analyses indicated hot spots of Cd concentrations in the vicinity of vascular bundles in response to Cd treatment, essentially bound to S-containing compounds as revealed by extended X-ray absorption fine structure and non-protein thiol compounds analyses. A preferential accumulation of Zn occurred in vascular bundle and spongy mesophyll in response to Zn treatment, and was mainly bound to O/N-ligands. Leaf proteomics and physiological status evidenced a protection of photosynthetically active tissues and the maintenance of cell turgor through specific distribution and complexation of toxic ions, reallocation of some essential elements, synthesis of proteins involved in photosynthetic apparatus or C-metabolism, and metabolite synthesis with some specificities regarding the considered heavy metal treatment.


Assuntos
Cádmio/metabolismo , Zinco/metabolismo , Zygophyllum/metabolismo , Transporte Biológico , Cádmio/análise , Clorofila/metabolismo , Terapia a Laser , Espectrometria de Massas , Fotossíntese , Folhas de Planta/metabolismo , Proteínas de Plantas/química , Proteínas de Plantas/isolamento & purificação , Proteínas de Plantas/metabolismo , Proteoma , Espectrometria por Raios X , Zinco/análise
12.
Talanta ; 269: 125379, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37979505

RESUMO

Quantification in 2D LA-ICP-MS mapping generally requires matrix-matched standards to minimize issues related to elemental fractionation. In addition, internal standardization is commonly applied to correct for instrumental drift and fluctuation, whereas also differences in ablated mass can be rectified for samples that cannot be sectioned and subjected to total ablation. However, it is crucial that the internal standard element is homogeneously distributed in the sample and that the laser light absorptivity is uniform over the surface. As in practice these requirements are often not met, this work will focus on correction of ablation rate differences within/between samples and standards by normalizing the element maps using the associated ablation volume per pixel as measured by optical profilometry. Due to the volume correction approach the element concentrations are no longer defined as mass per mass concentrations (in µg g-1) but by mass per volume concentrations (in µg cm-3), which can be interconverted in case matrix densities are known. The findings show that ablation volume-aided calibration yields more accurate element concentrations in 2D LA-ICP-MS maps for a decorative glass with highly varying elemental concentrations (murrina). This research presents a warning that if there are variations in ablation rates between samples and standards within and across matrices, even when their sensitivities are the same, generic LA-ICP-MS calibration protocols may not accurately depict the actual element concentrations.

13.
Talanta ; 271: 125712, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38309110

RESUMO

Laser ablation inductively coupled plasma - mass spectrometry (LA-ICP-MS) is a frequently used microanalytical technique in elemental analysis of solid samples. In most instances the use of matrix-matched calibration standards is necessary for the accurate determination of elemental concentrations. However, the main drawback of this approach is the limited availability of certified reference materials. Here, we present a novel conceptual framework in LA-ICP-MS quantification without the use of matrix-matched calibration standards but instead employment of an ablation volume-normalization method (via measurement of post-ablation line scan volumes by optical profilometry) in combination with a matrix-adapted fluence (slightly above the ablation threshold). This method was validated by cross-matrix quantification of reference materials typically investigated by LA-ICP-MS, including geological and biological materials. This allows for more accurate and precise multi-element quantification, and enables quantification of previously unquantifiable elements/materials.

14.
Anal Chim Acta ; 1287: 342089, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38182382

RESUMO

BACKGROUND: Recent papers on LA-ICP-MS have reported that certain elements are transported in particulate form, others in gaseous form and still others in a combination of both upon ablation of C-based materials. These two phases display different transport behaviour characteristics, potentially causing smearing in elemental maps, and could be processed differently in the ICP which raises concerns as to accuracy of quantification and emphasizes the need for matrix-matching of external standards. This work aims at a better understanding of two-phase sample transport by evaluating the peak profile changes observed upon varying parameters such as laser energy density and wavelength. RESULTS: It is demonstrated that upon ablation of gelatin, elements are transported predominantly in particulate phase, but already at low laser energy density, a significant fraction of some elements is transported in the gaseous phase, which is even more expressed at higher energy density. This behaviour is element-specific since the ratio of the signal intensity for the analyte element transported in gas phase to the total signal intensity was 0 % for 23Na, 43 % for 66Zn and as high as 95 % for 13C using a 193 nm laser. The results also suggest an effect of the laser wavelength, as all elements show either the same or higher amount of gas phase formation upon ablating with 213 nm versus 193 nm. It was even established that elements that fully occur in particulate form upon ablation using 193 nm laser radiation are partly converted into gaseous phase when using 213 nm. SIGNIFICANCE: This work provides a thorough investigation of the underexposed phenomenon of two-phase sample transport upon ablation of biological samples upon via LA-ICP-MS. It is shown that for some elements a fraction of the ablated material is converted and transported in the gas phase, which can lead to significant smearing effects. As such, it is important to evaluate element-specific peak profiles on beforehand and, if necessary, adapt instrument settings and slow down data acquisition.


Assuntos
Gelatina , Terapia a Laser , Gases , Análise Espectral , Espectrometria de Massas
15.
Talanta ; 263: 124699, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37267882

RESUMO

Laser beam profiles in analytical laser ablation - inductively coupled plasma - mass spectrometry (LA-ICP-MS) instruments are in general homogenized to produce a flat-top beam profile. However, in practice, they are mostly super-Gaussian in nature, and for small laser beam sizes (<5 µm) they even approach a Gaussian profile. This implies that the amount of surface material sampled by the laser (=ablation volume) directly depends on the beam profile and ablation grid. By contraction of the ablation grid (=sub-pixel mapping) not only more accurate surface sampling is realized, but also a higher pixel density, an improved spatial resolution, and a better signal-to-noise ratio. Although LA sampling is predominantly performed on an orthogonal grid, hexagonal or staggered/interleaved sampling may further improve the image quality as regular hexagons are more compact than squares (=lower perimeter/area) and suffer less from orientation bias (=lower anisotropy). Due to the current limitations of LA stages in executing precise hexagonal sampling with small beam sizes, computational protocols were employed to simulate LA-ICP-MS mapping. Simulation was performed by discrete convolution using the crater profile as the kernel, followed by the application/addition of Poisson/Flicker noise related to the local concentration and instrumental sensitivity/noise. A freely accessible online app was developed (https://laicpms-apps.ki.si/webapps/home/) to study the effect of sampling grid contraction (orthogonal and hexagonal) on the image map quality (spatial resolution and signal-to-noise ratio) by virtual ablation of phantoms. Comparison of experimental LA-ICP-MS maps obtained through orthogonal and hexagonal sampling methods could only be performed using a beam size of 150 µm and a macroscale inkjet-printed resolution target. This was due to the unavailability of precise hexagonal sampling stages and microscale resolution targets, which prevented the use of smaller beam sizes.

16.
Biometals ; 25(1): 231-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21874527

RESUMO

This work presents an analytical chemist's view on the sometimes unconscious use of arsenic trioxide in (bio)medical research. Arsenic trioxide is a frequently used chemical in cancer treatment research and its action to various malignant cells has been extensively studied and published. Unfortunately some research articles show trivial errors with regards to background knowledge of the chemical, handling the chemical, experimental design and interpretation of results like e.g. in a range of articles comparing advantages of tetraarsenic oxide over arsenic trioxide (dimeric/monomeric) although the dissolution of both yields the same active compound (HAsO(2)). To fully understand the implications of these errors we will highlight some of them with the intent to harmonize future work in this field.


Assuntos
Arsenicais , Pesquisa Biomédica , Óxidos , Antineoplásicos/química , Antineoplásicos/metabolismo , Antineoplásicos/uso terapêutico , Trióxido de Arsênio , Arsenicais/química , Arsenicais/metabolismo , Arsenicais/uso terapêutico , Humanos , Oxirredução , Óxidos/química , Óxidos/metabolismo , Óxidos/uso terapêutico , Células Tumorais Cultivadas
17.
Biometals ; 25(1): 103-13, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21822952

RESUMO

The ability of As(2)O(3) to induce apoptosis in various malignant cell lines has made it a potential treatment agent for several malignancies. In this study the chemical stability of As(2)O(3) (As(III)) in cell-free growth media with various compositions was studied (MEM with different amount of amino acids and DMEM). Special attention was given to evaluate the influence of serum (FBS; fetal bovine serum) absence and vitamin C addition on the oxidation of As(III) to As(V) in cell-free growth media. FBS is an important source of antioxidants and vitamin C (ascorbic acid) is acting as a prooxidant in millimolar concentrations. Media were incubated with As(III) (0.6, 2 and 7 µmol l(-1)) up to 72 h. Experiments were performed at 37°C in light or/and in the dark, with or without added serum (10%) or vitamin C (1.4, 0.14 mM). Metabolites were followed with high-performance liquid chromatography directly coupled to a hydride generation-atomic fluorescence spectrometry system. After 72 h up to 30% of As(III) was transformed into As(V) in MEMs and up to 35% in DMEM when exposed in dark. Light had no influence on transformations in MEMs, but changed the situation dramatically in DMEM where almost all As(III) was oxidized to As(V) after 72 h when exposed to light. Except for some faster oxidation rate the absence of FBS had little effect on the transformation rate in all media. The most visible impact on As(III) oxidation was observed by addition of vitamin C. Addition of vitamin C (1.4 mM) transformed almost all As(III) to As(V) within 72 h. In lower concentrations (0.14 mM) a pro-oxidative effect was still observed reaching approximately 60% oxidation of As(III) during 72 h. All oxidation processes could be explained by pseudo first order reaction kinetics, yielding reaction rates increasing with initial As(III) concentration and vitamin C concentration whereas the FBS content additionally increased the As(III) oxidation rate in the DMEM (light). The temporal oxidation of As(III) to As(V) in various cell-free growth media necessitates routine checking of the valence state of arsenic during cell culture experiments and the results of biological effects attributed to As(III) should be interpreted with caution. Special attention is needed particularly in cases with vitamin C which was acting pro-oxidatively in all conditions examined.


Assuntos
Antioxidantes/química , Arsenicais/química , Arsenitos/química , Ácido Ascórbico/química , Óxidos/química , Animais , Antineoplásicos/química , Trióxido de Arsênio , Bovinos , Técnicas de Cultura de Células/métodos , Linhagem Celular Tumoral , Meios de Cultura/química , Oxirredução
18.
Plants (Basel) ; 11(5)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35270142

RESUMO

Salinity is a growing global concern that affects the yield of crop species, including tomato (Solanum lycopersicum). Its wild relative Solanum chilense was reported to have halophyte properties. We compared salt resistance of both species during the reproductive phase, with a special focus on sodium localization in the flowers. Plants were exposed to NaCl from the seedling stage. Salinity decreased the number of inflorescences in both species but the number of flowers per inflorescence and sepal length only in S. lycopersicum. External salt supply decreased the stamen length in S. chilense, and it was associated with a decrease in pollen production and an increase in pollen viability. Although the fruit set was not affected by salinity, fruit weight and size decreased in S. lycopersicum. Concentrations and localization of Na, K, Mg, and Ca differed in reproductive structures of both species. Inflorescences and fruits of S. chilense accumulated more Na than S. lycopersicum. Sodium was mainly located in male floral organs of S. chilense but in non-reproductive floral organs in S. lycopersicum. The expression of Na transporter genes differed in flowers of both species. Overall, our results indicated that S. chilense was more salt-resistant than S. lycopersicum during the reproductive phase and that differences could be partly related to dissimilarities in element distribution and transport in flowers.

19.
Anal Bioanal Chem ; 401(2): 745-55, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21637930

RESUMO

The surface of two glass artefacts in mosaic style, probably fragments of conglomerate glass bowls dating back two millennia, was investigated by laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS). By rastering with the laser beam over a selected area of the surface of the glass artefacts, elemental oxide maps were generated. Quantification of the elemental oxides in the maps was achieved using a so-called sum normalization procedure, summating the elements-54 in total-as their oxides to 100% (w/w), without using an internal standard and applying only one external standard (NIST SRM glass 610). This results in a robust mapping procedure which automatically corrects for drift and defocusing issues. Sum normalization was applied to each pixel in the map separately and required a custom source code to process all the data in the tens of thousands of pixels to generate the elemental oxide concentration maps. The digital element maps generated upon rastering of the two glass artefacts are very compelling and are an excellent entry point to gain detailed insight into their fabrication and provenance using image analysis software for retrieval of localized elemental oxide concentrations and correlations.


Assuntos
Vidro/análise , Interpretação de Imagem Assistida por Computador , Lasers , Espectrometria de Massas , Óxidos/análise , Software , Propriedades de Superfície
20.
J Environ Monit ; 13(6): 1823-30, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21491038

RESUMO

The introduction of catalytic converters has led to a new environmental problem since catalysts emit platinum group elements (PGEs) which are among the least distributed elements in nature. Along with PGEs the vehicle exhaust catalysts contain also a number of stabilizers, commonly oxides of rare earth elements and alkaline earth elements such as Ce, La and Zr. Since vehicular emission of these elements has received little attention so far this work attempts to offer insight into their distribution and fate in the environment by measuring their speciation in road dust samples collected along several highways in Germany and a city centre (Saarbrücken). Speciation of the elements (fractionation into associated mineralogical phases) was carried out via a conventional sequential extraction protocol and the complexing abilities of humic substances in the organic matter were investigated by selective extraction methods in combination with size segregation. For evaluation purposes soil samples spiked with catalytic converter material were analyzed, showing a much lower fraction of Ce, La and Zr mobilized in comparison to the road dust samples. It was found that the elements were effectively bound to humic substances in road dust with a preference for complexation with low molecular weight compounds (<1600 Da).


Assuntos
Poluentes Atmosféricos/análise , Cério/análise , Poeira/análise , Lantânio/análise , Emissões de Veículos/análise , Zircônio/análise , Poluição do Ar/estatística & dados numéricos , Automóveis/estatística & dados numéricos , Monitoramento Ambiental , Substâncias Húmicas/análise , Solo/química , Poluentes do Solo/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA