Neuromodulation ; 22(4): 472-477, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30629330

RESUMO

INTRODUCTION: Clinical response to deep brain stimulation (DBS) strongly depends on the appropriate placement of the electrode in the targeted structure. Postoperative MRI is recognized as the gold standard to verify the DBS-electrode position in relation to the intended anatomical target. However, intraoperative computed tomography (iCT) might be a feasible alternative to MRI. MATERIALS AND METHODS: In this prospective noninferiority study, we compared iCT with postoperative MRI (24-72 hours after surgery) in 29 consecutive patients undergoing placement of 58 DBS electrodes. The primary outcome was defined as the difference in Euclidean distance between lead tip coordinates as determined on both imaging modalities, using the lead tip depicted on MRI as reference. Secondary outcomes were difference in radial error and depth, as well as difference in accuracy relative to target. RESULTS: The mean difference between the lead tips was 0.98 ± 0.49 mm (0.97 ± 0.47 mm for the left-sided electrodes and 1.00 ± 0.53 mm for the right-sided electrodes). The upper confidence interval (95% CI, 0.851 to 1.112) did not exceed the noninferiority margin established. The average radial error between lead tips was 0.74 ± 0.48 mm and the average depth error was determined to be 0.53 ± 0.40 mm. The linear Deming regression indicated a good agreement between both imaging modalities regarding accuracy relative to target. CONCLUSIONS: Intraoperative CT is noninferior to MRI for the verification of the DBS-electrode position. CT and MRI have their specific benefits, but both should be considered equally suitable for assessing accuracy.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda/normas , Monitorização Neurofisiológica Intraoperatória/normas , Imageamento por Ressonância Magnética/normas , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Encéfalo/cirurgia , Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
2.
Neurosurg Focus ; 35(5): E3, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24175863

RESUMO

OBJECT: Accurate placement of the leads is crucial in deep brain stimulation (DBS). To optimize the surgical positioning of the lead, a combination of anatomical targeting on MRI, electrophysiological mapping, and clinical testing is applied during the procedure. Electrophysiological mapping is usually done with microelectrode recording (MER), but the relatively undocumented semimicroelectrode recording (SMER) is a competing alternative. In this study the added value and safety of SMER for optimal lead insertion in the subthalamic nucleus (STN) in a consecutive cohort of patients with Parkinson disease (PD) was assessed. METHODS: Between 2001 and 2010, a consecutive single-center cohort of 46 patients with PD underwent DBS of the STN (85 lead insertions). After exclusion of 11 lead insertions for mostly technical reasons, 74 insertions were included for the assessment. Anatomical target localization was based on either 1.5-T MRI or fused 3-T MRI with CT, with reference to anterior commissure-posterior commissure coordinates. Electrophysiological mapping was performed with SMER. Intraoperative clinical testing was dominant in determining the final lead position. The target error was defined as the absolute distance between the anatomical or electrophysiological target and the final lead position. The effect of SMER on anatomical target error reduction and final target selection was analyzed. Also, the anatomical and electrophysiological target error was judged against the different imaging strategies. For safety evaluation, the adverse events related to all lead insertions were assessed. RESULTS: The use of SMER significantly reduced the anatomical target error from 1.7 (SD 1.6) mm to 0.8 (SD 1.3) mm (p < 0.0001). In particular, the anatomical target error based on 1.5-T MRI was significantly reduced by SMER, from 2.3 (SD 1.5) mm to 0.1 (SD 0.5) mm (p < 0.001). Anatomical target error reduction based on 3-T MRI fused with CT was not significantly influenced by SMER (p = 0.2), because the 3-T MRI-CT combination already significantly reduced the anatomical target error from 2.3 (SD 1.5) mm to 1.5 (SD 1.5) mm compared with 1.5-T MRI (p = 0.03). No symptomatic intracerebral hemorrhage was reported. Intracerebral infection was encountered in 1 patient following lead insertion. CONCLUSIONS: Semimicroelectrode recording has added value in targeting the STN in DBS for patients with PD based on 1.5-T MRI. The use of SMER does not significantly reduce the anatomical target error in procedures with fused 3-T MRI-CT studies and therefore might be omitted. With the absence of hemorrhagic complications, SMER-guided lead implantation should be considered a safe alternative to MER.


Assuntos
Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Microeletrodos , Neuroimagem/métodos , Doença de Parkinson/fisiopatologia , Núcleo Subtalâmico/fisiopatologia , Idoso , Estudos de Coortes , Estimulação Encefálica Profunda/instrumentação , Desenho de Equipamento , Feminino , Humanos , Masculino , Erros Médicos/prevenção & controle , Pessoa de Meia-Idade , Doença de Parkinson/cirurgia
3.
J Neurosurg ; 110(6): 1283-90, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19301961

RESUMO

OBJECT: The authors examined the accuracy of anatomical targeting during electrode implantation for deep brain stimulation in functional neurosurgical procedures. Special attention was focused on the impact that ventricular involvement of the electrode trajectory had on targeting accuracy. METHODS: The targeting error during electrode placement was assessed in 162 electrodes implanted in 109 patients at 2 centers. The targeting error was calculated as the shortest distance from the intended stereotactic coordinates to the final electrode trajectory as defined on postoperative stereotactic imaging. The trajectory of these electrodes in relation to the lateral ventricles was also analyzed on postoperative images. RESULTS: The trajectory of 68 electrodes involved the ventricle. The targeting error for all electrodes was calculated: the mean +/- SD and the 95% CI of the mean was 1.5 +/- 1.0 and 0.1 mm, respectively. The same calculations for targeting error for electrode trajectories that did not involve the ventricle were 1.2 +/- 0.7 and 0.1 mm. A significantly larger targeting error was seen in trajectories that involved the ventricle (1.9 +/- 1.1 and 0.3 mm; p < 0.001). Thirty electrodes (19%) required multiple passes before final electrode implantation on the basis of physiological and/or clinical observations. There was a significant association between an increased requirement for multiple brain passes and ventricular involvement in the trajectory (p < 0.01). CONCLUSIONS: Planning an electrode trajectory that avoids the ventricles is a simple precaution that significantly improves the accuracy of anatomical targeting during electrode placement for deep brain stimulation. Avoidance of the ventricles appears to reduce the need for multiple passes through the brain to reach the desired target as defined by clinical and physiological observations.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Eletrodos Implantados , Imageamento por Ressonância Magnética , Transtornos dos Movimentos/cirurgia , Técnicas Estereotáxicas , Ventrículos Cerebrais , Estudos de Coortes , Feminino , Humanos , Masculino , Transtornos dos Movimentos/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
4.
World Neurosurg ; 93: 410-2, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27368505

RESUMO

BACKGROUND: In deep brain stimulation (DBS), accurate placement of the lead is critical. Target definition is highly dependent on visual recognition on magnetic resonance imaging (MRI). We prospectively investigated whether the 7-T MRI enabled better visualization of targets and led to better placement of leads compared with the 1.5-T and the 3-T MRI. METHODS: Three patients with PD (mean, 55 years) were scanned on 1.5-, 3-, and 7-T MRI before surgery. Tissue contrast and signal-to-noise ratio were measured. Target coordinates were noted on MRI and during surgery. Differences were analyzed with post-hoc analysis of variance. RESULTS: The 7-T MRI demonstrated a significant improvement in tissue visualization (P < 0.005) and signal-to-noise ratio (P < 0.005). However, no difference in the target coordinates was found between the 7-T and the 3-T MRI. CONCLUSIONS: Although the 7-T MRI enables a significant better visualization of the DBS target in patients with PD, we found no clinical benefit for the placement of the DBS leads.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Imageamento por Ressonância Magnética/métodos , Doença de Parkinson/prevenção & controle , Doença de Parkinson/cirurgia , Implantação de Prótese/métodos , Eletrodos Implantados , Humanos , Doença de Parkinson/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento
5.
Front Neuroanat ; 9: 96, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26300739

RESUMO

BACKGROUND: Visualization of the precise course of the visual pathways is relevant to prevent damage that may inflict visual field deficits during neurosurgical resections. In particular the optic radiations (OR) are susceptible to such damage during neurosurgery. Cortical pathways can be mapped in vivo, by using Diffusion Tensor Imaging (DTI). Visualization of these pathways would be potentially helpful to prevent neurosurgical visual morbidity. In this study an anatomical dissection of the visual pathways was compared to DTI fiber tractography (DTI-FT) data of four human brains. The feasibility of a definition of a Safety Zone is investigated. METHODS: Four adult brains were dissected using Klingler's fiber dissection method, which allowed preparation of the OR. Measurements before and after dissection were used to establish distances from the cortex to the OR. DTI-scans were also obtained from these brains to determine the same distances. RESULTS: Measurements from specific landmark points on the cortex to the lateral border of the OR were performed in four brains. Analysis through DTI tractography corresponded with the dissection results. Based on the combined results of both dissection and DTI-FT, we defined a quantitative surgical Safety Zone with respect to various anatomical landmarks (in particular the ventricle system). CONCLUSION: We conclude that there is a good correlation between the visualizations of the optic pathways based on dissection and DTI. Furthermore, we conclude that defining a neurosurgical Safety Zone which could preserve the integrity of the OR during surgery, based on the combination of DTI-FT images and dissection is feasible.

6.
Clin Neurol Neurosurg ; 124: 51-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25016239

RESUMO

Diffusion tensor imaging (DTI) is a recent technique that utilizes diffusion of water molecules to make assumptions about white matter tract architecture of the brain. Early on, neurosurgeons recognized its potential value in neurosurgical planning, as it is the only technique that offers the possibility for in vivo visualization of white matter tracts. In this review we give an overview of the current advances made with this technique in neurosurgical practice. The effect of brain shift and the limitations of the technique are highlighted, followed by a comprehensive discussion on its objective value. Although there are many limitations and pitfalls associated with this technique, DTI can provide valuable additional diagnostic information to the neurosurgeon. We conclude that current evidence supports a role for DTI in the multimodal navigation during tumor surgery.


Assuntos
Neoplasias Encefálicas/cirurgia , Imagem de Tensor de Difusão/métodos , Neuronavegação/métodos , Imagem de Tensor de Difusão/normas , Humanos , Neuronavegação/normas