Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biochem Biophys Res Commun ; 681: 200-211, 2023 11 12.
Artigo em Inglês | MEDLINE | ID: mdl-37783118

RESUMO

Human heart tissues grown as three-dimensional spheroids and consisting of different cardiac cell types derived from pluripotent stem cells (hiPSCs) recapitulate aspects of human physiology better than standard two-dimensional models in vitro. They typically consist of less than 5000 cells and are used to measure contraction kinetics although not contraction force. By contrast, engineered heart tissues (EHTs) formed around two flexible pillars, can measure contraction force but conventional EHTs often require between 0.5 and 2 million cells. This makes large-scale screening of many EHTs costly. Our goals here were (i) to create a physiologically relevant model that required fewer cells than standard EHTs making them less expensive, and (ii) to ensure that this miniaturized model retained correct functionality. We demonstrated that fully functional EHTs could be generated from physiologically relevant combinations of hiPSC-derived cardiomyocytes (70%), cardiac fibroblasts (15%) and cardiac endothelial cells (15%), using as few as 1.6 × 104 cells. Our results showed that these EHTs were viable and functional up to 14 days after formation. The EHTs could be electrically paced in the frequency range between 0.6 and 3 Hz, with the optimum between 0.6 and 2 Hz. This was consistent across three downscaled EHT sizes tested. These findings suggest that miniaturized EHTs could represent a cost-effective microphysiological system for disease modelling and examining drug responses particularly in secondary screens for drug discovery.


Assuntos
Células-Tronco Pluripotentes Induzidas , Células-Tronco Pluripotentes , Humanos , Células Endoteliais , Técnicas de Cocultura , Miócitos Cardíacos/metabolismo , Contração Miocárdica , Engenharia Tecidual/métodos
2.
Biochem Biophys Res Commun ; 497(4): 1135-1141, 2018 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-28153730

RESUMO

Multi electrode arrays (MEAs) are increasingly used to detect external field potentials in electrically active cells. Recently, in combination with cardiomyocytes derived from human (induced) pluripotent stem cells they have started to become a preferred tool to examine newly developed drugs for potential cardiac toxicity in pre-clinical safety pharmacology. The most important risk parameter is proarrhythmic activity in cardiomyocytes which can cause sudden cardiac death. Whilst MEAs can provide medium- to high- throughput noninvasive assay platform, the translation of a field potential to cardiac action potential (normally measured by low-throughput patch clamp) is complex so that accurate assessment of drug risk to the heart is in practice still challenging. To address this, we used computational simulation to study the theoretical relationship between aspects of the field potential and the underlying cardiac action potential. We then validated the model in both primary mouse- and human pluripotent (embryonic) stem cell-derived cardiomyocytes showing that field potentials measured in MEAs could be converted to action potentials that were essentially identical to those determined directly by electrophysiological patch clamp. The method significantly increased the amount of information that could be extracted from MEA measurements and thus combined the advantages of medium/high throughput with more informative readouts. We believe that this will benefit the analysis of drug toxicity screening of cardiomyocytes using in time and accuracy.


Assuntos
Avaliação Pré-Clínica de Medicamentos/métodos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Miócitos Cardíacos/efeitos dos fármacos , Potenciais de Ação , Animais , Simulação por Computador , Humanos , Células-Tronco Pluripotentes Induzidas/citologia , Camundongos , Microeletrodos , Modelos Teóricos , Células-Tronco Pluripotentes/citologia
3.
Biochem Biophys Res Commun ; 482(2): 323-328, 2017 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-27856254

RESUMO

The polymer polydimethylsiloxane (PDMS) is widely used to build microfluidic devices compatible with cell culture. Whilst convenient in manufacture, PDMS has the disadvantage that it can absorb small molecules such as drugs. In microfluidic devices like "Organs-on-Chip", designed to examine cell behavior and test the effects of drugs, this might impact drug bioavailability. Here we developed an assay to compare the absorption of a test set of four cardiac drugs by PDMS based on measuring the residual non-absorbed compound by High Pressure Liquid Chromatography (HPLC). We showed that absorption was variable and time dependent and not determined exclusively by hydrophobicity as claimed previously. We demonstrated that two commercially available lipophilic coatings and the presence of cells affected absorption. The use of lipophilic coatings may be useful in preventing small molecule absorption by PDMS.


Assuntos
Bioensaio/métodos , Fármacos Cardiovasculares/química , Cromatografia Líquida de Alta Pressão/instrumentação , Dimetilpolisiloxanos/química , Avaliação Pré-Clínica de Medicamentos/métodos , Dispositivos Lab-On-A-Chip , Nylons/química , Absorção Fisico-Química , Fármacos Cardiovasculares/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Materiais Revestidos Biocompatíveis/química , Desenho de Equipamento , Análise de Falha de Equipamento , Lipídeos/química , Teste de Materiais , Preparações Farmacêuticas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA