Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Pediatr Res ; 2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38368497

RESUMO

OBJECTIVE: Concerns have been raised about the effect of skin color on the accuracy of transcutaneous bilirubin (TcB) measurements, a widely used method for hyperbilirubinemia diagnosis in newborns. Literature is inconclusive, with both reported under- and overestimations of the TcB with increasing skin pigmentation. Therefore, the influence of skin color on TcB measurements was systematically evaluated in a controlled, in vitro setting. METHODS: A bilirubin meter (JM-105) was evaluated on layered phantoms that mimic neonatal skin with varying dermal bilirubin concentrations (0-250 µmol/L) and varying epidermal melanosome volume fractions (0-40%; light-dark skin color). RESULTS: TcB measurements were influenced by skin pigmentation. Larger mimicked melanosome volume fractions and higher bilirubin levels led to larger underestimations of the measured TcB, compared to an unpigmented epidermis. In the in vitro setting of this study, these underestimations amounted to 26-132 µmol/L at a TcB level of 250 µmol/L. CONCLUSION: This in vitro study provides insight into the effect of skin color on TcB measurements: the TcB is underestimated as skin pigmentation increases and this effect becomes more pronounced at higher bilirubin levels. Our results highlight the need for improved TcB meter design and cautious interpretation of TcB readings on newborns with dark skin. IMPACT: Key message: Skin color influences transcutaneous bilirubin measurements: the darker the skin, the larger the underestimation. What this study adds to existing literature: Existing literature is inconclusive regarding the influence of skin color on transcutaneous bilirubin measurements. This study systematically evaluates and clarifies the influence of skin color on transcutaneous bilirubin measurements in a controlled, in vitro setting. IMPACT: This study aids to better interpret the measured TcB level in patients with varying skin colors, and is particularly important when using TcB meters on patients with dark skin colors.

2.
Br J Clin Pharmacol ; 90(6): 1418-1427, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38450797

RESUMO

AIMS: Little is known about the population pharmacokinetics (PPK) of vancomycin in neonates with perinatal asphyxia treated with therapeutic hypothermia (TH). We aimed to describe the PPK of vancomycin and propose an initial dosing regimen for the first 48 h of treatment with pharmacokinetic/pharmacodynamic target attainment. METHODS: Neonates with perinatal asphyxia treated with TH were included from birth until Day 6 in a multicentre prospective cohort study. A vancomycin PPK model was constructed using nonlinear mixed-effects modelling. The model was used to evaluate published dosing guidelines with regard to pharmacokinetic/pharmacodynamic target attainment. The area under the curve/minimal inhibitory concentration ratio of 400-600 mg*h/L was used as target range. RESULTS: Sixteen patients received vancomycin (median gestational age: 41 [range: 38-42] weeks, postnatal age: 4.4 [2.5-5.5] days, birth weight: 3.5 [2.3-4.7] kg), and 112 vancomycin plasma concentrations were available. Most samples (79%) were collected during the rewarming and normothermic phase, as vancomycin was rarely initiated during the hypothermic phase due to its nonempirical use. An allometrically scaled 1-compartment model showed the best fit. Vancomycin clearance was 0.17 L/h, lower than literature values for term neonates of 3.5 kg without perinatal asphyxia (range: 0.20-0.32 L/h). Volume of distribution was similar. Published dosing regimens led to overexposure within 24 h of treatment. A loading dose of 10 mg/kg followed by 24 mg/kg/day in 4 doses resulted in target attainment. CONCLUSION: Results of this study suggest that vancomycin clearance is reduced in term neonates with perinatal asphyxia treated with TH. Lower dosing regimens should be considered followed by model-informed precision dosing.


Assuntos
Antibacterianos , Asfixia Neonatal , Hipotermia Induzida , Modelos Biológicos , Vancomicina , Humanos , Recém-Nascido , Vancomicina/farmacocinética , Vancomicina/administração & dosagem , Hipotermia Induzida/métodos , Asfixia Neonatal/terapia , Asfixia Neonatal/tratamento farmacológico , Estudos Prospectivos , Masculino , Feminino , Antibacterianos/farmacocinética , Antibacterianos/administração & dosagem , Área Sob a Curva , Idade Gestacional , Relação Dose-Resposta a Droga
3.
Ther Drug Monit ; 46(3): 376-383, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38287875

RESUMO

BACKGROUND: Model validation procedures are crucial when population pharmacokinetic (PK) models are used to develop dosing algorithms and to perform model-informed precision dosing. We have previously published a population PK model describing the PK of gentamicin in term neonates with perinatal asphyxia during controlled therapeutic hypothermia (TH), which showed altered gentamicin clearance during the hypothermic phase dependent on gestational age and weight. In this study, the predictive performance and generalizability of this model were assessed using an independent data set of neonates with perinatal asphyxia undergoing controlled TH. METHODS: The external data set contained a subset of neonates included in the prospective observational multicenter PharmaCool Study. Predictive performance was assessed by visually inspecting observed-versus-predicted concentration plots and calculating bias and precision. In addition, simulation-based diagnostics, model refitting, and bootstrap analyses were performed. RESULTS: The external data set included 323 gentamicin concentrations of 39 neonates. Both the model-building and external data set included neonates from multiple centers. The original gentamicin PK model predicted the observed gentamicin concentrations with adequate accuracy and precision during all phases of controlled TH. Model appropriateness was confirmed with prediction-corrected visual predictive checks and normalized prediction distribution error analyses. Model refitting to the merged data set (n = 86 neonates with 935 samples) showed accurate estimation of PK parameters. CONCLUSIONS: The results of this external validation study justify the generalizability of the gentamicin dosing recommendations made in the original study for neonates with perinatal asphyxia undergoing controlled TH (5 mg/kg every 36 or 24 h with gestational age 36-41 and 42 wk, respectively) and its applicability in model-informed precision dosing.


Assuntos
Antibacterianos , Asfixia Neonatal , Gentamicinas , Hipotermia Induzida , Modelos Biológicos , Humanos , Gentamicinas/farmacocinética , Gentamicinas/uso terapêutico , Recém-Nascido , Hipotermia Induzida/métodos , Asfixia Neonatal/terapia , Estudos Prospectivos , Antibacterianos/farmacocinética , Antibacterianos/uso terapêutico , Masculino , Feminino , Idade Gestacional
4.
PLoS One ; 19(8): e0308470, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39093882

RESUMO

[This corrects the article DOI: 10.1371/journal.pone.0297363.].

5.
PLoS One ; 19(2): e0297363, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38416728

RESUMO

OBJECTIVE: The aim of this study is to assess the neonatal click Auditory Brainstem Response (ABR) results in relation to the subsequently determined mean hearing loss (HL) over 1, 2 and 4 kHz, as well as over 2 and 4 kHz. METHODS: Between 2004-2009, follow-up data were collected from Visual Reinforcement Audiometry (VRA) at 1 and 2 years and playaudiometry at 4 and 8 years of newborns who had failed neonatal hearing screening in the well-baby clinics and who had been referred to a single Speech and Hearing center. Hearing Level data were compared with ABR threshold-levels established during the first months of life. The Two One-Sided Tests equivalence procedure for paired means was applied, using a region of similarity equal to 10 dB. RESULTS: Initially, in 135 out of 172 children referred for diagnostic procedures hearing loss was confirmed in the neonatal period. In 106/135 of the HL children the eight-year follow-up was completed. Permanent conductive HL was established in 5/106 cases; the hearing thresholds were predominantly stable over time. Temporary conductive HL was found in 48/106 cases and the loss disappeared by 4 years of age at the latest. Sensorineural hearing loss (SNHL) was found in 53/106 cases, of which 13 were unilateral and 40 bilateral. ABR levels were equivalent (within a 10 dB range) to VRA levels at age 1 and 2 and play audiometry levels at age 4 and 8, both when VRA and play audiometry were averaged over both frequency ranges. CONCLUSION: Long term follow-up data of children with SNHL suggest that the initial click ABR level established in the first months of life, are equivalent to the hearing threshold measured at the age of 1, 2, 4 and 8 years for both mean frequency ranges. Click ABR can reliably be used as starting point for long-term hearing rehabilitation.


Assuntos
Surdez , Perda Auditiva Neurossensorial , Perda Auditiva , Lactente , Criança , Recém-Nascido , Humanos , Pré-Escolar , Seguimentos , Perda Auditiva/diagnóstico , Perda Auditiva Neurossensorial/diagnóstico , Testes Auditivos , Perda Auditiva Condutiva , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Audição , Limiar Auditivo/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA