RESUMO
An adapted method for the quantitative determination of isocyanates in air was implemented and validated in-house. The method was based on air sampling using an impinger flask containing di-n-butylamine (DBA) in toluene and a glass fibre filter in series. The DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. Studied isocyanates were isophorone diisocyanate, isocyanic acid (ICA), methyl isocyanate, ethyl isocyanate, propyl isocyanate, hexamethylene diisocyanate (HDI), 2,6- and 2,4-toluene diisocyanate, 4,4'-methylene diphenyl diisocyanate (MDI), phenyl isocyanate (PhI), MDI oligomers and different HDI adducts. Monitoring of selected reactions resulted in quantifications with correlation coefficients >0.995, within-batch relative standard deviation (RSD) of repeatability was <13% for all analytes. Between-batch RSD (reproducibility) was determined for all the compounds with the exception of the adducts and oligomers and was also <13%. As an additional validation procedure, the method was evaluated by exchanging field (air) and standard samples between two laboratories. The RSDs observed by the two laboratories were comparable. The concentrations determined were between 80 and 120% of each other, depending on the analyte and the individual concentrations. The method was applied in a large field study on exposure of workers in car repair shops and industrial painters with >500 samples.
Assuntos
Poluentes Ocupacionais do Ar/análise , Indústrias , Isocianatos/análise , Pintura , Poliuretanos , Butilaminas , Cromatografia Líquida/métodos , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Laboratórios , Exposição Ocupacional/análise , Espectrometria de Massas em Tandem/métodos , Tolueno 2,4-Di-IsocianatoRESUMO
The aim of the presented investigation was to document challenges encountered during implementation and qualification of a method for bisphenol A (BPA) analysis and to develop and discuss precautions taken to avoid and to monitor contamination with BPA during sample handling and analysis. Previously developed and published HPLC-MS/MS methods for the determination of unconjugated BPA (Markham et al. Journal of Analytical Toxicology, 34 (2010) 293-303) [17] and total BPA (Markham et al. Journal of Analytical Toxicology, 38 (2014) 194-203) [20] in human urine were combined and transferred into another laboratory. The initial method for unconjugated BPA was developed and evaluated in two independent laboratories simultaneously. The second method for total BPA was developed and evaluated in one of these laboratories to conserve resources. Accurate analysis of BPA at sub-ppb levels is a challenging task as BPA is a widely used material and is ubiquitous in the environment at trace concentrations. Propensity for contamination of biological samples with BPA is reported in the literature during sample collection, storage, and/or analysis. Contamination by trace levels of BPA is so pervasive that even with extraordinary care, it is difficult to completely exclude the introduction of BPA into biological samples and, consequently, contamination might have an impact on BPA biomonitoring data. The applied UPLC-MS/MS method was calibrated from 0.05 to 25ng/ml. The limit of quantification was 0.1ng/ml for unconjugated BPA and 0.2ng/ml for total BPA, respectively, in human urine. Finally, the method was applied to urine samples derived from 20 volunteers. Overall, BPA can be analyzed in human urine with acceptable recovery and repeatability if sufficient measures are taken to avoid contamination throughout the procedure from sample collection until UPLC-MS/MS analysis.
Assuntos
Compostos Benzidrílicos/química , Compostos Benzidrílicos/urina , Cromatografia Líquida de Alta Pressão/métodos , Fenóis/química , Fenóis/urina , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem/métodos , Compostos Benzidrílicos/isolamento & purificação , Humanos , Modelos Lineares , Fenóis/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
A generic method was developed for the fast determination of a wide range of drugs in serum or plasma. The methodology comprises generic solid-phase extraction, on-line coupled to gradient HPLC with tandem mass spectrometric detection (SPE-LC-MS/MS). The individual components of the SPE-LC-MS/MS system were optimized in an integrated approach to maximize the application range and minimize the method development time. The optimized generic SPE-LC-MS/MS protocol was evaluated for 11 drugs with different physicochemical properties. Good quantification for 10 out of 11 of the pharmaceuticals in serum or plasma could be readily achieved. The quantitative assays gave recoveries better than 95%, lower quantification limits of 0.2-2.0 ng/ml, acceptable precision and accuracy and good linearity over 2-4 orders of magnitude. Carry-over was determined to be in the range of 0.02-0.10%, without optimization.