Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
MAGMA ; 36(2): 159-173, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37081247

RESUMO

The 9.4 T scanner in Maastricht is a whole-body magnet with head gradients and parallel RF transmit capability. At the time of the design, it was conceptualized to be one of the best fMRI scanners in the world, but it has also been used for anatomical and diffusion imaging. 9.4 T offers increases in sensitivity and contrast, but the technical ultra-high field (UHF) challenges, such as field inhomogeneities and constraints set by RF power deposition, are exacerbated compared to 7 T. This article reviews some of the 9.4 T work done in Maastricht. Functional imaging experiments included blood oxygenation level-dependent (BOLD) and blood-volume weighted (VASO) fMRI using different readouts. BOLD benefits from shorter T2* at 9.4 T while VASO from longer T1. We show examples of both ex vivo and in vivo anatomical imaging. For many applications, pTx and optimized coils are essential to harness the full potential of 9.4 T. Our experience shows that, while considerable effort was required compared to our 7 T scanner, we could obtain high-quality anatomical and functional data, which illustrates the potential of MR acquisitions at even higher field strengths. The practical challenges of working with a relatively unique system are also discussed.


Assuntos
Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos
2.
Zhongguo Zhong Yao Za Zhi ; 48(3): 762-769, 2023 Feb.
Artigo em Zh | MEDLINE | ID: mdl-36872240

RESUMO

This study aimed to explore the effect of Ganmai Dazao Decoction on the ethology of rats with posttraumatic stress disorder(PTSD) and study the related mechanism through the changes in magnetic resonance imaging and protein expression. Sixty rats were randomly divided into 6 groups, namely the normal group, the model group, the low(1 g·kg~(-1)), medium(2 g·kg~(-1)), and high-dose Ganmai Dazao Decoction groups(4 g·kg~(-1)), and the positive control group(intragastric administration with 10.8 mg·kg~(-1) of fluoxetine), with 10 rats in each group. Two weeks after inducing PTSD by single-prolonged stress(SPS) in rats, the positive control group was given fluoxetine hydrochloride capsule by gavage, the low, medium, and high-dose groups were given Ganmai Dazao Decoction by gavage, and both the normal group and the model group were given the same volume of normal saline by gavage, each for 7 days. The open field experiment, elevated cross elevated maze, forced swimming experiment, and new object recognition test were carried out for the behavioral test. Three rats in each group were selected to detect the expression of neuropeptide receptor Y1(NPY1R) protein in the hippocampus by Western blot. Then, the other three rats in each group were selected to use the 9.4T magnetic resonance imaging experiment to observe the overall structural changes in the brain region and the anisotropy fraction of the hippocampus. The results of the open field experiment showed that the total distance and central distance of rats in the model group were significantly lower than those in the normal group, and the total distance and central distance of rats in the middle and high-dose Ganmai Dazao Decoction groups were higher than those in the model group. The results of the elevated cross maze test showed that medium and high-dose Ganmai Dazao Decoction remarkably increased the number of open arm entries and the residence time of open arm of rats with PTSD. The results of the forced swimming experiment showed that the immobility time in the water of the model group rats was significantly higher than that of the normal group, and Ganmai Dazao Decoction hugely reduced the immobility time in the water of rats with PTSD. The results of the new object recognition test showed that Ganmai Dazao Decoction significantly increased the exploration time of new objects and familiar objects in rats with PTSD. The results of Western blot showed that Ganmai Dazao Decoction significantly reduced the expression of NYP1R protein in the hippocampus of rats with PTSD. The 9.4T magnetic resonance examination found that there was no significant difference in the structural image among the groups. In the functional image, the fractional anisotropy(FA value) of the hippocampus in the model group was significantly lower than that in the normal group. The FA value of the hippocampus in the middle and high-dose Ganmai Dazao Decoction groups was higher than that in the model group. Ganmai Dazao Decoction reduces the injury of hippocampal neurons by inhibiting the expression of NYP1R in the hippocampus of rats with PTSD, thereby improving the nerve function injury of rats with PTSD and playing a neuroprotective role.


Assuntos
Etologia , Transtornos de Estresse Pós-Traumáticos , Animais , Ratos , Fluoxetina , Hipocampo , Aprendizagem em Labirinto
3.
Magn Reson Med ; 87(6): 2901-2913, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35129226

RESUMO

PURPOSE: Quantitative T1 and T2 mapping in non-human primates with whole-brain coverage is challenged by the requirement of sub-millimeter resolution and the inhomogeneity of the transmit magnetic field (B1+ ) covering a large field of view. The goal of the current study is to develop a magnetic resonance fingerprinting (MRF) method for simultaneous T1 and T2 mapping of the entire macaque brain within feasible scan time. METHODS: A three-dimensional (3D) MRF sequence with both inversion- and T2 -preparation modules was developed and evaluated on a 9.4 T preclinical scanner. Data acquisition used a 3D stack-of-spirals trajectory, with undersampling along both the in-plane and the through-plane directions. The effect of B1+ inhomogeneity was accounted for by matching the acquired fingerprint to a dictionary simulated with the B1+ factors measured from a separate scan. In vitro and ex vivo studies were performed to evaluate the accuracy and the undersampling capacity of the MRF method. The application of the MRF method for in vivo, brain-wide T1 and T2 mapping was demonstrated on macaques at 4, 6, and 12 years of age. RESULTS: The MRF method enabled highly repeatable T1 and T2 mapping at high spatial resolution (0.35 × 0.35 × 1 mm3 ) with an acceleration factor of 24. In vivo studies showed significant age-related T2 reduction in deep gray nuclei including the globus pallidus, the putamen, and the caudate nucleus. CONCLUSIONS: This study demonstrates the first MRF study for brain-wide, multi-parametric quantification in non-human primates with sub-millimeter resolution.


Assuntos
Macaca , Imageamento por Ressonância Magnética , Animais , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
4.
J Anat ; 240(1): 166-171, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34342906

RESUMO

The palatine tonsils form an important part of the human immune system. Together with the other lymphoid tonsils of Waldeyer's tonsillar ring, they act as the first line of defense against ingested or inhaled pathogens. Although histologically stained sections of the palatine tonsil are widely available, they represent the tissue only in two dimensions and do not provide reference to three-dimensional space. Such a representation of a tonsillar specimen based on imaging data as a 3D anatomical reconstruction is lacking both in scientific publications and especially in textbooks. As a first step in this direction, the objective of the present work was to image a resected tonsil specimen with high spatial resolution in a 9.4 T small-bore pre-clinical MRI and to combine these data with data from the completely sectioned and H&E stained same palatine tonsil. Based on the information from both image modalities, a 3D anatomical sketch was drawn by a scientific graphic artist. In perspective, such studies could help to overcome the difficulty of capturing the spatial extent and arrangement of anatomical structures from 2D images and to establish a link between three-dimensional anatomical preparations and two-dimensional sections or illustrations, as they have been found so far in common textbooks and anatomical atlases.


Assuntos
Imageamento Tridimensional , Tonsila Palatina , Humanos , Imageamento por Ressonância Magnética , Tonsila Palatina/diagnóstico por imagem , Tonsila Palatina/patologia
5.
NMR Biomed ; 35(8): e4728, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35297104

RESUMO

PURPOSE: To optimize transmit k-space trajectories for a wide range of excitation targets and to design "universal pTx RF pulses" based on these trajectories. METHODS: Transmit k-space trajectories (stack of spirals and SPINS) were optimized to best match different excitation targets using the parameters of the analytical equations of spirals and SPINS. The performances of RF pulses designed based on optimized and non-optimized trajectories were compared. The optimized trajectories were utilized for universal pulse design. The universal pulse performances were compared with subject specific tailored pulse performances. The OTUP workflow (optimization of transmit k-space trajectories and universal pulse calculation) was tested on three test target excitation patterns. For one target (local excitation of a central area in the human brain) the pulses were tested in vivo at 9.4 T. RESULTS: The workflow produced appropriate transmit k-space trajectories for each test target. Utilization of an optimized trajectory was crucial for the pulse performance. Using unsuited trajectories diminished the performance. It was possible to create target specific universal pulses. However, not every test target is equally well suited for universal pulse design. There was no significant difference in the in vivo performance between subject specific tailored pulses and a universal pulse at 9.4 T. CONCLUSIONS: The proposed workflow further exploited and improved the universal pulse concept by combining it with gradient trajectory optimization for stack of spirals and SPINS. It emphasized the importance of a well suited trajectory for pTx RF pulse design. Universal and tailored pulses performed with a sufficient degree of similarity in simulations and a high degree of similarity in vivo. The implemented OTUP workflow and the B0 /B1+ map data from 18 subjects measured at 9.4 T are available as open source (https://github.com/ole1965/workflow_OTUP.git).


Assuntos
Aumento da Imagem , Interpretação de Imagem Assistida por Computador , Algoritmos , Humanos , Imageamento por Ressonância Magnética , Fluxo de Trabalho
6.
NMR Biomed ; 35(10): e4776, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35607903

RESUMO

A method to estimate phosphorus (31 P) transversal relaxation times (T2 s) of coupled spin systems is demonstrated. Additionally, intracellular and extracellular pH and relaxation-corrected metabolite concentrations are reported. Echo time (TE) series of 31 P metabolite spectra were acquired using stimulated echo acquisition mode (STEAM) localization. Spectra were fitted using LCModel with accurately modeled Versatile Simulation, Pulses and Analysis (VeSPA) basis sets accounting for J-evolution of the coupled spin systems. T2 s were estimated by fitting a single exponential two-parameter model across the TE series. Fitted inorganic phosphate frequencies were used to calculate pH, and estimated relaxation times were used to determine the relaxation-corrected brain metabolite concentrations on an assumption of 3 mM γ-ATP. The method was demonstrated in healthy human brain at a field strength of 9.4 T. T2 times of ATP and nicotinamide adenine dinucleotide (NAD) were shortest between 8 and 20 ms, followed by T2 s of inorganic phosphate between 25 and 50 ms, and phosphocreatine with a T2 of 100 ms. Phosphomonoesters and phosphodiesters had the longest T2 s of about 130 ms. The measured T2 s are comparable with literature values and fit in a decreasing trend with increasing field strengths. Calculated pHs and metabolite concentrations are also comparable with literature values.


Assuntos
Encéfalo , Fósforo , Trifosfato de Adenosina/metabolismo , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Humanos , Espectroscopia de Ressonância Magnética , Fosfatos/metabolismo , Fósforo/metabolismo
7.
Neuroradiology ; 64(4): 753-764, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34984522

RESUMO

PURPOSE: Resective epilepsy surgery is a well-established, evidence-based treatment option in patients with drug-resistant focal epilepsy. A major predictive factor of good surgical outcome is visualization and delineation of a potential epileptogenic lesion by MRI. However, frequently, these lesions are subtle and may escape detection by conventional MRI (≤ 3 T). METHODS: We present the EpiUltraStudy protocol to address the hypothesis that application of ultra-high field (UHF) MRI increases the rate of detection of structural lesions and functional brain aberrances in patients with drug-resistant focal epilepsy who are candidates for resective epilepsy surgery. Additionally, therapeutic gain will be addressed, testing whether increased lesion detection and tailored resections result in higher rates of seizure freedom 1 year after epilepsy surgery. Sixty patients enroll the study according to the following inclusion criteria: aged ≥ 12 years, diagnosed with drug-resistant focal epilepsy with a suspected epileptogenic focus, negative conventional 3 T MRI during pre-surgical work-up. RESULTS: All patients will be evaluated by 7 T MRI; ten patients will undergo an additional 9.4 T MRI exam. Images will be evaluated independently by two neuroradiologists and a neurologist or neurosurgeon. Clinical and UHF MRI will be discussed in the multidisciplinary epilepsy surgery conference. Demographic and epilepsy characteristics, along with postoperative seizure outcome and histopathological evaluation, will be recorded. CONCLUSION: This protocol was reviewed and approved by the local Institutional Review Board and complies with the Declaration of Helsinki and principles of Good Clinical Practice. Results will be submitted to international peer-reviewed journals and presented at international conferences. TRIAL REGISTRATION NUMBER: www.trialregister.nl : NTR7536.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsias Parciais , Imageamento por Ressonância Magnética , Criança , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Epilepsias Parciais/diagnóstico por imagem , Epilepsias Parciais/cirurgia , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Resultado do Tratamento
8.
Sensors (Basel) ; 22(11)2022 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-35684895

RESUMO

The optimized size of a single-channel surface radio frequency (RF) coil for mouse body images in a 9.4 T magnetic resonance imaging (MRI) system was determined via electromagnetic-field analysis of the signal depth according to the size of a single-channel coil. The single-channel surface RF coils used in electromagnetic field simulations were configured to operate in transmission/reception mode at a frequency of 9.4 T-400 MHz. Computational analysis using the finite-difference time-domain method was used to assess the single-channel surface RF coil by comparing single-channel surface RF coils of varying sizes in terms of |B1|-, |B1+|-, |B1-|- and |E|-field distribution. RF safety for the prevention of burn injuries to small animals was assessed using an analysis of the specific absorption rate. A single-channel surface RF coil with a 20 mm diameter provided optimal B1-field distribution and RF safety, thus confirming that single-channel surface RF coils with ≥25 mm diameter could not provide typical B1-field distribution. A single-channel surface RF coil with a 20 mm diameter for mouse body imaging at 9.4 T MRI was recommended to preserve the characteristics of single-channel surface RF coils, and ensured that RF signals were applied correctly to the target point within RF safety guidelines.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Simulação por Computador , Campos Eletromagnéticos , Imageamento por Ressonância Magnética/métodos , Camundongos , Imagens de Fantasmas
9.
Magn Reson Med ; 86(6): 2957-2965, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34309065

RESUMO

PURPOSE: The goal of this study was to propose a novel localized proton MR spectroscopy (MRS) sequence that reduces signal loss due to J-modulation in the rat brain in vivo. METHODS: Sprague-Dawley rats were studied at 9.4 T. A semi-LASER sequence with evenly distributed echo-time (TE ) was used, and a 90° J-refocusing pulse was inserted at TE /2. Proton spectra were acquired at two TE s (30 and 68 ms), with and without the J-refocused pulse. Data were processed in MATLAB and quantified with LCModel. RESULTS: The J-refocused spectrum acquired at TE = 30 ms did not show any signal losses due to J-modulation and had comparable spectral pattern to the one acquired with semi-LASER using the minimum achievable TE . Higher signal amplitudes for glutamine, γ-aminobutyric acid and glutathione led to more reliable quantification precision for these metabolites. The refocused signal intensities at TE = 68 ms were also unaffected by J-modulation but were smaller than the signals at TE = 30 ms mainly due to transverse T2 relaxation of metabolites. CONCLUSION: The proposed localized MRS sequence will be beneficial in both animal and human MRS studies when using ultra-short TE is not possible while also providing more reliable quantification precision for J-coupled metabolites.


Assuntos
Glutamina , Prótons , Animais , Encéfalo/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Espectroscopia de Prótons por Ressonância Magnética , Ratos , Ratos Sprague-Dawley
10.
Magn Reson Med ; 86(5): 2368-2383, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34219281

RESUMO

PURPOSE: To present 31 P whole brain MRSI with a high spatial resolution to probe quantitative tissue analysis of 31 P MRSI at an ultrahigh field strength of 9.4 Tesla. METHODS: The study protocol included a 31 P MRSI measurement with an effective resolution of 2.47 mL. For SNR optimization, the nuclear Overhauser enhancement at 9.4 Tesla was investigated. A sensitivity correction was achieved by applying a low rank approximation of the γ-adenosine triphosphate signal. Group analysis and regression on individual volunteers were performed to investigate quantitative concentration differences between different tissue types. RESULTS: Differences in gray and white matter tissue 31 P concentrations could be investigated for 12 different 31 P resonances. In addition, the first highly resolved quantitative MRSI images measured at B0 = 9.4 Tesla of 31 P detectable metabolites with high SNR could be presented. CONCLUSION: With an ultrahigh field strength B0 = 9.4 Tesla, 31 P MRSI moves further toward quantitative metabolic imaging, and subtle differences in concentrations between different tissue types can be detected.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética
11.
Magn Reson Med ; 86(5): 2589-2603, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34180089

RESUMO

PURPOSE: To demonstrate that the concept of "universal pTx pulses" is applicable to local excitation applications. METHODS: A database of B0 / B1+ maps from eight different subjects was acquired at 9.4T. Based on these maps, universal pulses that aim at local excitation of the visual cortex area in the human brain (with a flip angle of 90° or 7°) were calculated. The remaining brain regions should not experience any excitation. The pulses were designed with an extension of the "spatial domain method." A 2D and a 3D target excitation pattern were tested, respectively. The pulse performance was examined on non-database subjects by Bloch simulations and in vivo at 9.4T using a GRE anatomical MRI and a presaturated TurboFLASH B1+ mapping sequence. RESULTS: The calculated universal pulses show excellent performance in simulations and in vivo on subjects that were not contained in the design database. The visual cortex region is excited, while the desired non-excitation areas produce the only minimal signal. In simulations, the pulses with 3D target pattern show a lack of excitation uniformity in the visual cortex region; however, in vivo, this inhomogeneity can be deemed acceptable. A reduced field of view application of the universal pulse design concept was performed successfully. CONCLUSIONS: The proposed design approach creates universal local excitation pulses for a flip angle of 7° and 90°, respectively. Providing universal pTx pulses for local excitation applications prospectively abandons the need for time-consuming subject-specific B0 / B1+ mapping and pTx-pulse calculation during the scan session.


Assuntos
Imageamento por Ressonância Magnética , Córtex Visual , Algoritmos , Encéfalo/diagnóstico por imagem , Bases de Dados Factuais , Frequência Cardíaca , Humanos , Imagens de Fantasmas , Córtex Visual/diagnóstico por imagem
12.
Neuropathol Appl Neurobiol ; 47(1): 157-170, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32559314

RESUMO

AIMS: Sudden unexpected death in epilepsy (SUDEP) likely arises as a result of autonomic dysfunction around the time of a seizure. In vivo MRI studies report volume reduction in the medulla and other brainstem autonomic regions. Our aim, in a pathology series, is to correlate regional quantitative features on 9.4T MRI with pathology measures in medullary regions. METHODS: Forty-seven medullae from 18 SUDEP, 18 nonepilepsy controls and 11 epilepsy controls were studied. In 16 cases, representing all three groups, ex vivo 9.4T MRI of the brainstem was carried out. Five regions of interest (ROI) were delineated, including the reticular formation zone (RtZ), and actual and relative volumes (RV), as well as T1, T2, T2* and magnetization transfer ratio (MTR) measurements were evaluated on MRI. On serial sections, actual and RV estimates using Cavalieri stereological method and immunolabelling indices for myelin basic protein, synaptophysin and Microtubule associated protein 2 (MAP2) were carried out in similar ROI. RESULTS: Lower relative RtZ volumes in the rostral medulla but higher actual volumes in the caudal medulla were observed in SUDEP (P < 0.05). No differences between groups for T1, T2, T2* and MTR values in any region was seen but a positive correlation between T1 values and MAP2 labelling index in RtZ (P < 0.05). Significantly lower MAP2 LI were noted in the rostral medulla RtZ in epilepsy cases (P < 0.05). CONCLUSIONS: Rostro-caudal alterations of medullary volume in SUDEP localize with regions containing respiratory regulatory nuclei. They may represent seizure-related alterations, relevant to the pathophysiology of SUDEP.


Assuntos
Morte Súbita/patologia , Epilepsia/patologia , Imageamento por Ressonância Magnética , Morte Súbita Inesperada na Epilepsia/patologia , Tronco Encefálico/metabolismo , Humanos , Imageamento por Ressonância Magnética/métodos , Convulsões/patologia
13.
NMR Biomed ; 34(2): e4455, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33269481

RESUMO

Tissue omega-3 (ω-3) content is biologically important to disease; however, its quantification with magnetic resonance spectroscopy in vivo is challenging due to its low concentration. In addition, the ω-3 methyl resonance (≈ 0.98 ppm) overlaps that of the non-ω-3 (≈ 0.90 ppm), even at 9.4 T. We demonstrate that a Point-RESolved Spectroscopy (PRESS) sequence with an echo time (TE) of 109 ms resolves the ω-3 and non-ω-3 methyl peaks at 9.4 T. Sequence efficacy was verified on five oils with differing ω-3 fat content; the ω-3 content obtained correlated with that measured using 16.5 T NMR (R2 = 0.97). The PRESS sequence was also applied to measure ω-3 content in visceral adipose tissue of three different groups (all n = 3) of mice, each of which were fed a different 20% w/w fat diet. The fat portion of the diet consisted of low (1.4%), medium (9.0%) or high (16.4%) ω-3 fat. The sequence was also applied to a control mouse fed a standard chow diet (5.6% w/w fat, which was 5.9% ω-3). Gas chromatography (GC) analysis of excised tissue was performed for each mouse. The ω-3 fat content obtained with the PRESS sequence correlated with the GC measures (R2 = 0.96). Apparent T2 times of methyl protons were assessed by obtaining spectra from the oils and another group of four mice (fed the high ω-3 diet) with TE values of 109 and 399 ms. Peak areas were fit to a mono-exponentially decaying function and the apparent T2 values of the ω-3 and non-ω-3 methyl protons were 906 ± 148 and 398 ± 78 ms, respectively, in the oils. In mice, the values were 410 ± 68 and 283 ± 57 ms for ω-3 and non-ω-3 fats, respectively.


Assuntos
Ácidos Graxos Ômega-3/análise , Gordura Intra-Abdominal/química , Espectroscopia de Ressonância Magnética/métodos , Ração Animal , Animais , Cromatografia Gasosa , Gorduras na Dieta/administração & dosagem , Ácidos Graxos Ômega-3/administração & dosagem , Feminino , Espectroscopia de Ressonância Magnética/instrumentação , Camundongos
14.
Magn Reson Med ; 83(1): 254-261, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31429990

RESUMO

PURPOSE: To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS: Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running pCASL-EPI and CASL-EPI sequences, with labeling B1 amplitudes (B1ave ) of 3, 5, and 7 µT and using a dedicated labeling RF coil or a volume coil. From the temperature time courses, the corresponding specific absorption rate (SAR) was computed. A trade-off between SAR and labeling quality was determined based on measured inversion efficiencies. RESULTS: ASL experiments with standard parameters (B1ave = 5 µT, Tacq = 4 min, labeling with volume coil) lead to a brain temperature increase due to RF of 0.72 ± 0.46 K for pCASL and 0.25 ± 0.17 K for CASL. Using a dedicated labeling coil reduced the RF-induced SAR by a factor of 10 in the brain and a factor of 2 in the neck. Besides SAR due to RF, heat from the coil decoupling circuits produced significant temperature increases. When labeling with a dedicated coil, this mechanism was the dominant source of brain heating. At equivalent RF-SAR, CASL provided slightly superior label efficiency to pCASL and is therefore the preferred sequence when an ASL coil is available. CONCLUSION: B1ave = 4-5 µT provided a good compromise between label efficiency and SAR, both for pCASL and CASL. The sensitivity of animals to heating should be taken into account when optimizing preclinical ASL protocols and may require reducing scan duration or lowering B1ave .


Assuntos
Encéfalo/diagnóstico por imagem , Angiografia por Ressonância Magnética , Pescoço/diagnóstico por imagem , Reto/diagnóstico por imagem , Marcadores de Spin , Animais , Tecnologia de Fibra Óptica , Temperatura Alta , Campos Magnéticos , Masculino , Fibras Ópticas , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
15.
NMR Biomed ; 33(3): e4191, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31829485

RESUMO

Pulsed arterial spin labelling remains a non-invasive and highly used method for the study of rodent cerebral blood flow (CBF). Flow-sensitive alternating inversion recovery (FAIR) is one of the most commonly used MR-sequences for this purpose and exists with many different strategies to record the images. This study investigates Look-Locker (LL) TrueFISP readout for FAIR as an alternative to the standard EPI readout, which is provided by the manufacturer. The aim was to show the improved image quality using TrueFISP and to verify the reproducibility of the determination of the cerebral blood flow values. The measurement of many inversion points also allowed to investigate the influence of the correct blood relaxation rate on the fit of the CBF data. For the LL-FAIR TrueFISP an in-house written method was created. The method was tested on a group of C57BL/6 mice at the field strength of 9.4 T. The results show CBF maps with less distortion than for EPI and the values found are in good agreement with the literature. A comparison of the CBF values found with EPI and LL-TrueFISP shows very small differences, most being not significant. In conclusion, the method presented gives equivalent CBF maps in comparison to standard FAIR-EPI. Both methods have the same measurement time. TrueFISP has the advantage to EPI of producing undistorted images over larger areas of the mouse brain. It is advisable to check the value of the blood relaxation rate by measurement or to estimate it as a fitting parameter.


Assuntos
Artérias/diagnóstico por imagem , Imagem Ecoplanar , Marcadores de Spin , Animais , Circulação Cerebrovascular/fisiologia , Camundongos Endogâmicos C57BL , Tálamo/diagnóstico por imagem , Tálamo/fisiologia
16.
NMR Biomed ; 32(12): e4180, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31518031

RESUMO

MRS of 13 C4 -labelled glutamate (13 C4 -Glu) during an infusion of a carbon-13 (13 C)-labelled substrate, such as uniformly labelled glucose ([U-13 C6 ]-Glc), provides a measure of Glc metabolism. The presented work provides a single-shot indirect 13 C detection technique to quantify the approximately 2.51 ppm 13 C4 -Glu satellite proton (1 H) peak at 9.4 T. The methodology is an optimized point-resolved spectroscopy (PRESS) sequence that minimizes signal contamination from the strongly coupled protons of N-acetylaspartate (NAA), which resonate at approximately 2.49 ppm. J-coupling evolution of protons was characterized numerically and verified experimentally. A (TE1 , TE2 ) combination of (20 ms, 106 ms) was found to be suitable for minimizing NAA signal in the 2.51 ppm 1 H 13 C4 -Glu spectral region, while retaining the 13 C4 -Glu 1 H satellite peak. The efficacy of the technique was verified on phantom solutions and on two rat brains in vivo during an infusion of [U-13 C6 ]-Glc. LCModel was employed for analysis of the in vivo spectra to quantify the 2.51 ppm 1 H 13 C4 -Glu signal to obtain Glu C4 fractional enrichment time courses during the infusions. Cramér-Rao lower bounds of about 8% were obtained for the 2.51 ppm 13 C4 -Glu 1 H satellite peak with the optimal TE combination.


Assuntos
Isótopos de Carbono/metabolismo , Glucose/metabolismo , Ácido Glutâmico/metabolismo , Espectroscopia de Prótons por Ressonância Magnética , Coloração e Rotulagem , Animais , Encéfalo/metabolismo , Metaboloma , Imagens de Fantasmas , Ratos , Fatores de Tempo
17.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 36(1): 116-120, 2019 Feb 25.
Artigo em Zh | MEDLINE | ID: mdl-30887785

RESUMO

For rat spinal magnetic resonance imaging (MRI) experiments, due to the lower main magnetic field strength, shallower detected depth and poor spatial compatibility of the traditional radio frequency (RF) coil, the image signal-to-noise ratio (SNR) of rat spinal was rather lower. In this paper, a RF coil for rat spinal MRI at 9.4 T was developed to improve the image quality and at the same time to avoid the space limitation while scanning in special conditions (cardiac catheterization, etc.). In this article, open birdcage structure was built and magnetic field distribution was calculated. The phantom and rat spine MRI imaging were experimented at 9.4 T to verify the advantage of the coil in rat spine MRI application.

18.
Neuroimage ; 168: 211-221, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28025130

RESUMO

Magnetic resonance spectroscopic imaging (MRSI) is a promising technique for mapping the spatial distribution of multiple metabolites in the human brain. These metabolite maps can be used as a diagnostic tool to gain insight into several biochemical processes and diseases in the brain. In comparison to lower field strengths, MRSI at ultra-high field strengths benefits from a higher signal to noise ratio (SNR) as well as higher chemical shift dispersion, and hence spectral resolution. This study combines the benefits of an ultra-high field magnet with the advantages of an ultra-short TE and TR single-slice FID-MRSI sequence (such as negligible J-evolution and loss of SNR due to T2 relaxation effects) and presents the first metabolite maps acquired at 9.4T in the healthy human brain at both high (voxel size of 97.6µL) and ultra-high (voxel size of 24.4µL) spatial resolutions in a scan time of 11 and 46min respectively. In comparison to lower field strengths, more anatomically-detailed maps with higher SNR from a larger number of metabolites are shown. A total of 12 metabolites including glutamate (Glu), glutamine (Gln), N-acetyl-aspartyl-glutamate (NAAG), Gamma-aminobutyric acid (GABA) and glutathione (GSH) are reliably mapped. Comprehensive description of the methodology behind these maps is provided.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Adulto , Humanos , Espectroscopia de Prótons por Ressonância Magnética/instrumentação
19.
Neuroimage ; 168: 181-198, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28712992

RESUMO

Magnetic Resonance Spectroscopy (MRS) allows for a non-invasive and non-ionizing determination of in vivo tissue concentrations and metabolic turn-over rates of more than 20 metabolites and compounds in the central nervous system of humans. The aim of this review is to give a comprehensive overview about the advantages, challenges and advances of ultra-high field MRS with regard to methodological development, discoveries and applications from its beginnings around 15 years ago up to the current state. The review is limited to human brain and spinal cord application at field strength of 7T and 9.4T and includes all relevant nuclei (1H, 31P, 13C).


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Neuroimagem/métodos , Ressonância Magnética Nuclear Biomolecular/métodos , Espectroscopia de Prótons por Ressonância Magnética/métodos , Humanos , Neuroimagem/instrumentação , Ressonância Magnética Nuclear Biomolecular/instrumentação , Espectroscopia de Prótons por Ressonância Magnética/instrumentação
20.
Magn Reson Med ; 79(3): 1314-1324, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28585234

RESUMO

PURPOSE: To evaluate a prescan-based radiofrequency phase-correction strategy for unbalanced pseudo-continuous arterial spin labeling (pCASL) at 9.4 T in vivo and to test its robustness toward suboptimal shim conditions. METHODS: Label and control interpulse phases were optimized separately by means of two prescans in rats. The mean perfusion as well as the interhemispherical symmetry were measured for several phase combinations (optimized versus theoretical phases) to evaluate the correction quality. Interpulse phases were also optimized under degraded shim conditions (i.e., up to four times the study shim values) to test the strategy's robustness. RESULTS: For all tested shim conditions, the full arterial spin labeling (ASL) signal could be restored. Without any correction, the relative ASL signal was 1.4 ± 1.7%. It increased to 3.6 ± 1.4% with an optimized label phase and to 5.3 ± 1.2% with optimized label and control phases. Moreover, asymmetry between brain hemispheres, which could be as high as 100% without phase optimization, was dramatically reduced to 1 ± 3% when applying optimized label and control phases. CONCLUSIONS: Pseudo-continuous ASL at high magnetic field is very sensitive to shim conditions. Label and control radiofrequency phase optimization based on prescans robustly maximizes the ASL signal obtained with unbalanced pCASL and minimizes the asymmetry between hemispheres. Magn Reson Med 79:1314-1324, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Algoritmos , Animais , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Masculino , Ratos , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA