Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Rev Cardiovasc Med ; 25(2): 48, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-39077333

RESUMO

Background: Ventricular functional mitral regurgitation (FMR) is a common morbidity in patients with heart failure (HF). In addition to guideline-directed medical therapy, mitral valve (MV) repair or replacement has become an option for such patients. However, the impact of different treatments on cardiac remodeling, function, and clinical outcomes remains unclear. Methods: We systematically searched PubMed, EMBASE, Medline, Clinical Trials.gov, and the Cochrane Central Register of Controlled Trials with search terms related to mitral regurgitation, mitral valve repair, surgical mitral valve replacement, mitral annuloplasty device, and MitraClip. The outcomes were left ventricular ejection fraction (LVEF), left ventricular (LV) remodeling, all-cause mortality, cardiovascular death, and HF hospitalization. Sensitivity analysis was performed by removing high-bias risk studies. The analysis was done by Review Manager 5.4 Analyzer and MedCalc Statistical Software version 19.2.6. Results: This meta-analysis included 10 studies with a total of 2533 patients (567 with transcatheter MitraClip, 823 with surgical MV repair, 651 with surgical MV replacement, and 492 with medical therapy). Our meta-analysis revealed that surgical MV repair had significant improvement in LVEF compared to the surgical MV replacement (mean differences (MD) 2.32, [95% CI 0.39, 4.25]), while transcatheter MitraClip treatment was associated with LVEF reduction (MD -4.82, [95% CI -7.29, -2.34]). In terms of LV remodeling, transcatheter MitraClip treatment was associated with improvement in left ventricular end-diastolic volume (MD -10.36, [95% CI -18.74, -1.99]). Furthermore, compared to surgical MV replacement, surgical MV repair was not associated with a reduction of all-cause mortality (risk ratio (RR) 0.83, [95% CI 0.61, 1.13]) and cardiovascular death (RR 0.95, [95% CI 0.56, 1.62]), while transcatheter MitraClip was associated with reduced risk of all-cause mortality (RR 0.87, [95% CI 0.78, 0.98]). Conclusions: Surgical MV repair was associated with significant improvement in LVEF but had no significant effect on all-cause mortality compared to surgical MV replacement. Transcatheter MitraClip was associated with better long-term survival than the non-MitraClip group, thus, transcatheter MitraClip could be considered an alternative treatment in patients with HF-complicated ventricular FMR.

2.
Artigo em Inglês | MEDLINE | ID: mdl-39099535

RESUMO

Transcutaneous aortic valve replacement (TAVR) has evolved from a complex procedure meant only for patients at prohibitive risk for surgery to a commonly performed procedure across a wide variety of clinical scenarios including the treatment of failed aortic valve bioprosthesis. Annuloplasty rings in the aortic position such as HAART 300 (Biostable Science and Engineering) have been introduced in the management of native aortic regurgitation. Percutaneous management of failed bioprosthesis rings in the aortic position has not been widely described. We present a case of a 69-year-old man with recurrent aortic regurgitation successfully treated with TAVR using a SAPIEN 3 valve within a HAART 300 ring.

3.
Ann Noninvasive Electrocardiol ; 29(1): e13104, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38288512

RESUMO

OBJECTIVE: This study aimed to investigate the structure of the mitral valve in patients undergoing mitral valvuloplasty (MVP) using real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). The main objective was to study the relationship between intraoperative annuloplasty ring size and mitral valve structure dimensions, with a focus on exploring the application value of RT-3D-TEE in MVP. METHODS: A total of 28 patients with degenerative mitral regurgitation (DMR), who underwent MVP between February and September 2022, as well as 12 normal control cases, were enrolled in this study. The MV annulus and leaflets were quantitatively analyzed using MVN software. RESULTS: The DMR group exhibited significantly greater dimensions in various parameters of the mitral valve, including the anterolateral-to-posteromedial diameter (DAlPm ), anterior-to-posterior diameter (DAP ), annulus height (HA ), three-dimensional annulus circumference (CA3D ), two-dimensional annulus area (AA2D ), anterior leaflet area (Aant ), posterior leaflet area (Apost ), anterior leaflet length (Lant ), posterior leaflet length (Lpost ), and tenting volume (Vtent ) compared to the control group. CONCLUSION: Real-time three-dimensional transesophageal echocardiography provides valuable insights into the morphological structure of the mitral valve and lesion location. It can aid in surgical decision-making, validate the success of MVP, and potentially reduce mortality and complications associated with mitral valve repair procedures.


Assuntos
Valvuloplastia com Balão , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral , Humanos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Eletrocardiografia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia
4.
Clin Anat ; 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867517

RESUMO

Anomalies of coronary venous system, the valve of the coronary sinus (Thebesian valve) and other cardiac malformations may make interventions through the coronary sinus difficult. These variants may pose a challenge in cannulating the coronary sinus for retrograde cardioplegia and for interventions performed through the coronary sinus by cardiac electrophysiologist/interventional cardiologist. Retrograde cardioplegia is an established method of myocardial protection with advantages, indications, and complications. A good knowledge of the anatomy of the coronary sinus and its variants is important in understanding the difficulties encountered while cannulating the coronary sinus for the delivery of retrograde cardioplegia, cardiac resynchronization therapy, treatment of arrhythmias, and percutaneous mitral valve annuloplasty.

5.
Heart Lung Circ ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38981831

RESUMO

AIM: Although current guidelines recommend concomitant tricuspid annuloplasty for moderate or greater tricuspid regurgitation (TR) and/or dilated annulus, there remains significant variation in undertaking concomitant tricuspid valve surgery (TVA) across different centres. This meta-analysis aimed to compare the clinical outcomes of concomitant tricuspid valve surgery for patients with moderate or greater TR and/or dilated annulus at the time of mitral valve (MV) surgery. METHOD: A systematic review of the literature using six databases. Eligible studies include comparative studies on TVA concomitant with MV surgery versus MV surgery alone. A meta-analysis was performed on studies reporting outcomes of interest to quantify the effects of concomitant tricuspid ring annuloplasty. RESULTS: Two randomised controlled trials and six cohort studies were included in the analysis. 1,941 patients were included in the analysis, of whom, 1,090 underwent concomitant TVA and 851 underwent MV surgery alone. Pooled analysis demonstrated that there was less progression of moderate/severe TR in the concomitant group (3.0% vs 9.6%; odds ratio [OR] 0.29; 95% confidence interval [CI] 0.13-0.55; p=0.0001). There was no significant difference in in-hospital mortality (3.0% vs 3.8%; OR 0.79; 95% CI 0.47-1.34; p=0.38). The rate of permanent pacemaker implantation was higher in the concomitant group although this did not reach statistical significance (7.6% vs 5.3%; OR 1.30; 95% CI 0.85-1.98; p=0.23). Cardiopulmonary bypass was longer in the concomitant TVA group by 20 minutes (mean difference 13.9-26.0; p<0.00001). CONCLUSIONS: Our study demonstrated that concomitant tricuspid ring annuloplasty at the time of MV surgery is associated with a significantly lower rate of TR progression without increasing the operative mortality. There is a trend towards a higher permanent pacemaker implantation rate although this did not reach statistical significance.

6.
Rev Cardiovasc Med ; 24(6): 174, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39077514

RESUMO

Background: The ideal position of suture annuloplasty relative to the aortic annulus (internal or external) remains unclear. This study aimed to investigate the effectiveness of internal and external suture annuloplasty for isolated type 1 bicuspid aortic valve (BAV) repair. Electrocardiogram (ECG)-gated computed tomography (CT) was used to compare the two techniques and analyze their impact on the aortic annulus. Methods: We retrospectively analyzed 20 patients who underwent isolated type 1 BAV repair with either internal or external suture annuloplasty. Each group included 10 patients with comparable clinical features. Preoperative and postoperative ECG-gated CT scans were performed to assess the anatomical relationship between the ventricular-aortic junction (VAJ) and virtual basal ring (VBR), and to measure the height of annuloplasty from the VBR at predefined landmarks in both groups. Perioperative annular geometries, including annular area and perimeter, were measured to quantify the impact of annuloplasty on annular expansibility. The discrepancy between the postoperative annular dimension and size of the Hegar dilator were compared between groups to evaluate the effectiveness of annuloplasty. Results: In both groups, VAJ was higher than VBR at the right coronary (RC) ostium (7.7 ± 3.3 mm) and the raphe (7.9 ± 1.5 mm). The height from the VBR to the external suture annuloplasty shared a similar pattern at the RC ostium and raphe (5.3 ± 1.1 mm and 4.8 ± 1.0 mm, respectively). In contrast, the height differences were minimal for these landmarks in the internal group. Postoperative annular area expansibility decreased in the internal group compared to preoperative levels (4.9 ± 2.3% vs. 8.9 ± 5.5%, p = 0.038), while no significant change was found in the external group (7.6 ± 4.1% vs. 6.5 ± 2.8%, p = 0.473). The internal group showed less area discrepancy between the VBR and the Hegar dilator both at systole (10.1 ± 3.7% vs. 30.1 ± 16.6%, p = 0.004) and diastole (5.7 ± 4.9% vs. 20.9 ± 14.5%, p = 0.009) compared to the external group. Conclusions: Internal suture annuloplasty results in better positioning relative to the VBR than external suture annuloplasty due to the absence of VAJ interference. While this results in more precise annular reduction and less expansibility in the short term, a long-term follow-up evaluation is necessary to assess its effectiveness.

7.
J Mech Behav Biomed Mater ; 152: 106453, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38335648

RESUMO

Tricuspid valve leaflets have historically been considered "passive flaps". However, we have recently shown that tricuspid leaflets actively remodel in sheep with functional tricuspid regurgitation. We hypothesize that these remodeling-induced changes reduce leaflet coaptation and, therefore, contribute to valvular dysfunction. To test this, we simulated the impact of remodeling-induced changes on valve mechanics in a reverse-engineered computer model of the human tricuspid valve. To this end, we combined right-heart pressures and tricuspid annular dynamics recorded in an ex vivo beating heart, with subject-matched in vitro measurements of valve geometry and material properties, to build a subject-specific finite element model. Next, we modified the annular geometry and boundary conditions to mimic changes seen in patients with pulmonary hypertension. In this model, we then increased leaflet thickness and stiffness and reduced the stretch at which leaflets stiffen, which we call "transition-λ." Subsequently, we quantified mean leaflet stresses, leaflet systolic angles, and coaptation area as measures of valve function. We found that leaflet stresses, leaflet systolic angle, and coaptation area are sensitive to independent changes in stiffness, thickness, and transition-λ. When combining thickening, stiffening, and changes in transition-λ, we found that anterior and posterior leaflet stresses decreased by 26% and 28%, respectively. Furthermore, systolic angles increased by 43%, and coaptation area decreased by 66%; thereby impeding valve function. While only a computational study, we provide the first evidence that remodeling-induced leaflet thickening and stiffening may contribute to valvular dysfunction. Targeted suppression of such changes in diseased valves could restore normal valve mechanics and promote leaflet coaptation.


Assuntos
Hipertensão Pulmonar , Valva Tricúspide , Humanos , Animais , Ovinos , Catéteres , Simulação por Computador , Pressão
8.
Interv Cardiol Clin ; 13(2): 249-255, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432767

RESUMO

Functional mitral regurgitation (FMR) is a common valvular heart disease in the geriatric population across the United States. This patient cohort is multimorbid and often has a prohibitive risk for conventional open-heart surgery. The diverse anatomic pathology of FMR is a complex problem and unfortunately does not have a universal solution. Carillon Mitral Contour System (Cardiac Dimensions, Kirkland, WA, USA) is a new device that provides transcatheter annular remodeling. In this review article, the authors summarize the evidence for the Carillon Mitral Contour System for FMR.


Assuntos
Doenças das Valvas Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Idoso , Humanos , Insuficiência da Valva Mitral/cirurgia
9.
World J Pediatr Congenit Heart Surg ; 15(3): 353-362, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38145581

RESUMO

Background: The current technique used in severe mitral regurgitation in children can occasionally lead to residual regurgitation. To address this issue, the posterior annulus elevation technique was developed to enhance coaptation and reduce residual lesions. This study aims to evaluate the effectiveness of this technique in reducing residual regurgitation during mitral valve repair in children. Methods: A total of 64 patients aged <18 years old undergoing mitral valve repair were randomized into two groups: the intervention (with posterior annulus elevation) group and the control group, which underwent conventional repair techniques. Various parameters, including coaptation area, residual mitral regurgitation, clinical outcomes, metabolic, and hemolytic markers, were measured on days 0, 5, 2 weeks, and 3 months after surgery. Results: The intervention group (n = 32) showed a significant reduction in residual mitral regurgitation compared with the control group (n = 32) on each evaluation. At three months after surgery, we found that the posterior annulus elevation technique could be a protective factor that reduces the chance of residual regurgitation compared with the control group (RR = 0.31; confidence interval: 0.18-0.54; P ≤ .001). Coaptation length and index were also found to be significantly higher in the intervention group (P ≤ .001). Clinical outcomes, metabolic markers, and hemolysis marker did not show any significant differences between the two groups. Conclusions: The posterior annulus elevation technique demonstrated effectiveness in reducing residual mitral regurgitation and improving coaptation area in pediatric mitral valve repair. This technique showed better short-term surgical outcomes in children with mitral regurgitation compared with the conventional technique.


Assuntos
Insuficiência da Valva Mitral , Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Masculino , Feminino , Valva Mitral/cirurgia , Criança , Pré-Escolar , Resultado do Tratamento , Anuloplastia da Valva Mitral/métodos , Seguimentos , Lactente , Adolescente , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos
10.
Cardiovasc Eng Technol ; 15(2): 224-231, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38238600

RESUMO

PURPOSE: The valve-sparing aortic root replacement (VSARR) procedure was developed to preserve the aortic valve apparatus to replace aneurysmal aortic roots with synthetic grafts and to eliminate associated aortic regurgitation (AR). However, residual post-repair AR is not uncommon and has been found to be associated with recurrent AR and future reoperation. METHODS: We designed and manufactured a 3D-printed, external adjustable symmetrically extensible (EASE) aortic annuloplasty ring that can symmetrically reduce the aortic annulus diameter via a radial constriction, compliant mechanism. An ex vivo porcine VSARR model with annular dilation and AR was developed (n = 4) and used for hemodynamic, echocardiography, and high-speed videography data collection. RESULTS: After ring annuloplasty repair using the EASE aortic ring, the regurgitant fraction decreased from 23.6 ± 6.9% from the VSARR model to 7.4 ± 5.6% (p = 0.05), which was similar to that measured from baseline with a regurgitant fraction of 10.2 ± 3.9% (p = 0.34). The leaflet coaptation height after annuloplasty repair also significantly increased from that measured in VSARR model (0.4 ± 0.1 cm) to 0.9 ± 0.1 cm (p = 0.0004), a level similar to that measured in baseline (1.1 ± 0.1 cm, p = 0.28). CONCLUSION: Using an ex vivo VSARR model, the EASE ring successfully reduced AR by reducing the annular diameter and improving leaflet coaptation. With its broad applicability and ease of use, this device has the potential to have a significant impact on patients suffering worldwide from AR due to root aneurysms.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica , Anuloplastia da Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Impressão Tridimensional , Desenho de Prótese , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Animais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Anuloplastia da Valva Cardíaca/instrumentação , Sus scrofa , Implante de Prótese de Valva Cardíaca/instrumentação , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Modelos Animais de Doenças , Modelos Cardiovasculares
11.
Front Cardiovasc Med ; 11: 1297304, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38464845

RESUMO

Introduction: Volume overload from mitral regurgitation can result in left ventricular systolic dysfunction. To prevent this, it is essential to operate before irreversible dysfunction occurs, but the optimal timing of intervention remains unclear. Current echocardiographic guidelines are based on 2D linear measurement thresholds only. We compared volumetric CT-based and 2D echocardiographic indices of LV size and function as predictors of post-operative systolic dysfunction following mitral repair. Methods: We retrospectively identified patients with primary mitral valve regurgitation who underwent repair between 2005 and 2021. Several indices of LV size and function measured on preoperative cardiac CT were compared with 2D echocardiography in predicting post-operative LV systolic dysfunction (LVEFecho <50%). Area under the curve (AUC) was the primary metric of predictive performance. Results: A total of 243 patients were included (mean age 57 ± 12 years; 65 females). The most effective CT-based predictors of post-operative LV systolic dysfunction were ejection fraction [LVEFCT; AUC 0.84 (95% CI: 0.77-0.92)] and LV end systolic volume indexed to body surface area [LVESViCT; AUC 0.88 (0.82-0.95)]. The best echocardiographic predictors were LVEFecho [AUC 0.70 (0.58-0.82)] and LVESDecho [AUC 0.79 (0.70-0.89)]. LVEFCT was a significantly better predictor of post-operative LV systolic dysfunction than LVEFecho (p = 0.02) and LVESViCT was a significantly better predictor than LVESDecho (p = 0.03). Ejection fraction measured by CT demonstrated significantly greater reproducibility than echocardiography. Discussion: CT-based volumetric measurements may be superior to established 2D echocardiographic parameters for predicting LV systolic dysfunction following mitral valve repair. Validation with prospective study is warranted.

12.
J Cardiothorac Surg ; 19(1): 164, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561823

RESUMO

BACKGROUND: Mitral regurgitation is a frequent valvular disease, with an increasing prevalence. We analyzed the short-term outcomes of mitral valve repair procedures conducted in our clinic using a new semirigid annuloplasty ring featuring a gradual saddle shape design. METHODS: We retrospectively analyzed mitral valve repair surgeries performed at our Institution between December 2019 and November 2021 with the MEMO 4D semirigid annuloplasty ring. RESULTS: In total, 53 patients were included in the study. Mean patient age was 63.6 ± 11.7 years. Most patients presented with degenerative mitral valve regurgitation (N = 44; 83%). The grade of mitral regurgitation was equal or more than 3 + in 98.1% of the patients (N = 52). The most used ring size was size 34 mm (N = 30, 56.6%). There was no intraoperative or hospital mortality. No cases of stroke, bleeding, endocarditis or other major complications occurred. At discharge, most patients were in NYHA class I. Postoperative echocardiographic results showed no (90.6%) or 1+ (5.7%) mitral valve regurgitation. Only 1 patient (1.9%) presented with mitral valve regurgitation grade 2+. Mean postoperative transvalvular gradient was low (mean = 3.3 ± 1.2 mmHg). No cases of LVOT obstruction or systolic anterior motion occurred. CONCLUSIONS: Our series showed excellent mitral valve competency and very satisfactory early clinical outcomes. The transesophageal echocardiographic follow-up, despite obtained in a limited number of patients, further confirmed the effectiveness of findings of this preliminary experience.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Estudos Retrospectivos , Desenho de Prótese , Anuloplastia da Valva Mitral/efeitos adversos , Ecocardiografia , Resultado do Tratamento
13.
J Am Coll Cardiol ; 83(17): 1656-1668, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38658105

RESUMO

BACKGROUND: Tricuspid valve annuloplasty (TA) during mitral valve repair (MVr) is associated with increased risk of permanent pacemaker (PPM) implantation, but the magnitude of risk and long-term clinical consequences have not been firmly established. OBJECTIVES: This study assesses the incidence rates of PPM implantation after isolated MVr and following MVr with TA as well as the associated long-term clinical consequences of PPM implantation. METHODS: State-mandated hospital discharge databases of New York and California were queried for patients undergoing MVr (isolated or with concomitant TA) between 2004 and 2019. Patients were stratified by whether or not they received a PPM within 90 days of index surgery. After weighting by propensity score, survival, heart failure hospitalizations (HFHs), endocarditis, stroke, and reoperation were compared between patients with or without PPM. RESULTS: A total of 32,736 patients underwent isolated MVr (n = 28,003) or MVr + TA (n = 4,733). Annual MVr + TA volumes increased throughout the study period (P < 0.001, trend), and PPM rates decreased (P < 0.001, trend). The incidence of PPM implantation <90 days after surgery was 7.7% for MVr and 14.0% for MVr + TA. In 90-day conditional landmark-weighted analyses, PPMs were associated with reduced long-term survival among MVr (HR: 1.96; 95% CI: 1.75-2.19; P < 0.001) and MVr + TA recipients (HR: 1.65; 95% CI: 1.28-2.14; P < 0.001). In both surgical groups, PPMs were also associated with an increased risk of HFH (HR: 1.56; 95% CI: 1.27-1.90; P < 0.001) and endocarditis (HR: 1.95; 95% CI: 1.52-2.51; P < 0.001), but not with stroke or reoperation. CONCLUSIONS: Compared to isolated MVr, adding TA to MVr was associated with a higher risk of 90-day PPM implantation. In both surgical groups, PPM implantation was associated with an increase in mortality, HFH, and endocarditis.


Assuntos
Marca-Passo Artificial , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Marca-Passo Artificial/efeitos adversos , Valva Tricúspide/cirurgia , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estudos Retrospectivos , Anuloplastia da Valva Cardíaca/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento
14.
JTCVS Open ; 17: 111-120, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420560

RESUMO

Background: Tricuspid valve disease significantly affects 1.6 million Americans. The gold standard treatment for tricuspid disease is the implantation of annuloplasty devices. These ring-like devices come in various shapes and sizes. Choices for both shape and size are most often made by surgical intuition rather than scientific rationale. Methods: To understand the impact of shape and size on valve mechanics and to provide a rational basis for their selection, we used a subject-specific finite element model to conduct a virtual case study. That is, we implanted 4 different annuloplasty devices of 6 different sizes in our virtual patient. After each virtual surgery, we computed the coaptation area, leaflet end-systolic angles, leaflet stress, and chordal forces. Results: We found that contoured devices are better at normalizing end-systolic angles, whereas the one flat device, the Edwards Classic, maximized the coaptation area and minimized leaflet stress and chordal forces. We further found that reducing device size led to increased coaptation area but also negatively impacted end-systolic angles, stress, and chordal forces. Conclusions: Based on our analyses of the coaptation area, leaflet motion, leaflet stress, and chordal forces, we found that device shape and size have a significant impact on valve mechanics. Thereby, our study also demonstrates the value of simulation tools and device tests in "virtual patients." Expanding our study to many more valves may, in the future, allow for universal recommendations.

15.
JACC Cardiovasc Interv ; 17(12): 1470-1481, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38925751

RESUMO

BACKGROUND: A novel echocardiography-based definition of atrial functional tricuspid regurgitation (A-FTR) has shown superior outcomes in patients undergoing conservative treatment or tricuspid valve transcatheter edge-to-edge repair. Its prognostic significance for transcatheter tricuspid valve annuloplasty (TTVA) outcomes is unknown. OBJECTIVES: This study sought to investigate prognostic, clinical, and technical implications of A-FTR phenotype in patients undergoing TTVA. METHODS: This multicenter study investigated clinical and echocardiographic outcomes up to 1 year in 165 consecutive patients who underwent TTVA for A-FTR (characterized by the absence of tricuspid valve tenting, midventricular right ventricular [RV] dilatation, and impaired left ventricular ejection fraction) and nonatrial functional tricuspid regurgitation (NA-FTR). RESULTS: A total of 62 A-FTR and 103 NA-FTR patients were identified, with the latter exhibiting more pronounced RV remodeling. Compared to baseline, the tricuspid regurgitation (TR) grade at discharge was significantly reduced (P < 0.001 for both subtypes), and TR ≤II was achieved more frequently in A-FTR (85.2% vs 60.8%; P = 0.001). Baseline TR grade and A-FTR phenotype were independently associated with TR ≤II at discharge and 30 days. In multivariate analyses, A-FTR phenotype was a strong predictor (OR: 5.8; 95% CI: 2.1-16.1; P < 0.001) of TR ≤II at 30 days. At 1 year, functional class had significantly improved compared to baseline (both P < 0.001). One-year mortality was lower in A-FTR (6.5% vs 23.8%; P = 0.011) without significant differences in heart failure hospitalizations (13.3% vs 22.7%; P = 0.188). CONCLUSIONS: Direct TTVA effectively reduces TR in both A-FTR, which is a strong and independent predictor of achieving TR ≤II, and NA-FTR. Even though NA-FTR showed more RV remodeling at baseline, both phenotypes experienced similar symptomatic improvement, emphasizing the benefit of TTVA even in advanced disease stages. Additionally, phenotyping was of prognostic relevance in patients undergoing TTVA.


Assuntos
Cateterismo Cardíaco , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade , Feminino , Masculino , Idoso , Valva Tricúspide/fisiopatologia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Anuloplastia da Valva Cardíaca/instrumentação , Fatores de Risco , Idoso de 80 Anos ou mais , Recuperação de Função Fisiológica , Remodelação Ventricular , Função Ventricular Esquerda , Fenótipo , Função Ventricular Direita , Estudos Retrospectivos , Pessoa de Meia-Idade , Volume Sistólico , Valor Preditivo dos Testes
16.
J Cardiothorac Surg ; 19(1): 299, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38789973

RESUMO

OBJECTIVE: Mitral valve failure is one of the most common valvular heart diseases worldwide. Valve replacement and repair have an impact on the quality of life of patients. Therefore, the present study was conducted to compare the quality of life in patients with mitral valve replacement and those who underwent mitral valve repair. METHODS: In this cross-sectional study, we considered all cardiac patients with ischemic mitral insufficiency who underwent mitral valve repair and patients with a history of valve replacement in Imam Ali Hospital of Kermanshah between 2014 and 2020. Two Minnesota and general quality of life questionnaires along with a checklist for demographic variables were used for data collection. Data analysis was performed using SPSS version 21 software. RESULTS: The mean quality of life score based on the general quality of life scale in the valve repair group was 32.33 (SD = 2.29) and in the valve replacement group 32.89(SD = 2.60), (p = 0.917). Also, mean quality of life, as measured by the Minnesota MLHFQ was 60.89(SD = 17.67) in the valve repair group and 63.42 (SD = 12.13) in the valve replacement group (p = 0.308). The results showed that the average general quality of life was different in study groups regarding education. Tukey's post hoc test showed that the average general quality of life in illiterate people is significantly lower than in people with academic degrees (P-value = 0.001). CONCLUSION: The quality of life of the patients in both the valve repair and replacement groups was at an average level. There was no significant difference between the general quality of life and the Minnesota scales, suggesting that both tools can be effectively used to measure patients' quality of life. The study's findings can be valuable for monitoring patients, screening for conditions, and enhancing communication between doctors and patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Qualidade de Vida , Humanos , Qualidade de Vida/psicologia , Estudos Transversais , Masculino , Feminino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/psicologia , Valva Mitral/cirurgia , Irã (Geográfico) , Idoso , Inquéritos e Questionários , Adulto
17.
J Clin Med ; 13(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38892924

RESUMO

Objectives: Mitral valve repair is the current standard approach for mitral valve regurgitation. However, patients suffering from functional mitral regurgitation have a significant risk of recurrent regurgitation. Adjustable mitral rings may provide a solution for this adverse event. Methods: A single-center, first-in-man clinical study was performed on patients suffering from mitral valve regurgitation. Patients were implanted with the study ring and followed for six months. A balloon catheter can be inserted into the study ring frame at any time after implantation and inflated independently in the areas P1, P2, or P3, which reduces the anterior-posterior diameter. Results: Five patients (75.4 ± 6.1 years; EuroSCORE II 2.1 ± 0.9%; three female) were successfully implanted. Mechanisms of mitral regurgitation were prolapse of the P2-segment in three patients and annular dilation in two patients. Surgical implantation according to the protocol was feasible and is described herein. Median cardiopulmonary bypass time and cross clamp time were 105 (118; 195) and 94 (90; 151) min, respectively. The median intensive care unit stay was 2 (2; 3) days. No perioperative, 30-day, or 6-month mortality was observed, and the repair was stable without residual or recurrent regurgitation ≥ grade 2. All patients reached the primary endpoint without device-related morbidity. Conclusions: Successful implantation was completed in five patients without device-related adverse events. Ring implantation was safe and feasible for all patients. The opportunity of post-implant adjustment to improve leaflet coaptation is a promising new therapeutic strategy that is assessed in a phase II study.

18.
Artigo em Inglês | MEDLINE | ID: mdl-38995834

RESUMO

OBJECTIVES: The Tri-Ad Adams tricuspid annuloplasty ring is a recent innovative prosthesis characterized by a semi-rigid central component and fully flexible extremities. The goal of this study was to assess the short-term and mid-term results following implantation of the Tri-Ad Adams ring. METHODS: A retrospective analysis was conducted on patients who underwent tricuspid annuloplasty using the Tri-Ad Adams ring between August 2016 and October 2021. RESULTS: Our study enrolled a total of 248 participants. The median age was 64.0 (interquartile range: 56.0-71.5) years. The median EuroSCORE II was 4.3% (2.7-7.5%), with 37 patients (14.9%) having a history of cardiac operations. Tricuspid regurgitation of grade 2-3 was observed in 63.7% of cases, and the median tricuspid annular diameter was 3.3 (2.8-3.6) cm. Concurrent procedures included mitral valve replacement (n = 160, 64.5%), mitral valve repair (n = 75, 30.2%), aortic valve replacement (n = 72, 29.0%) and the maze procedure (n = 170, 68.5%). Immediate postoperative tricuspid regurgitation≥moderate was present in 1 patient (0.4%). Early death occurred in 14 patients (5.6%). Major complications included low cardiac output syndrome (n = 18, 0.3%), acute kidney injury (n = 14, 5.6%) and permanent pacemaker placement (n = 15, 6.0%). According to the Kaplan-Meier analysis, the 4-year rates of freedom from overall mortality and moderate-to-severe tricuspid regurgitation were 96.9% and 91.6%, respectively. There were no incidents of tricuspid valve reoperations, ring detachment or significant tricuspid stenosis (trans-tricuspid valve gradient ≥ 5 mmHg). CONCLUSIONS: Tricuspid annuloplasty utilizing the Tri-Ad Adams ring demonstrated favourable outcomes in both the early and midterm periods. Further studies are warranted to confirm the long-term results.

19.
Artigo em Inglês | MEDLINE | ID: mdl-38914371

RESUMO

OBJECTIVES: In remodeling valve-sparing root replacement with external annuloplasty, we compare long-term outcomes of a calibrated expansible extra-aortic ring with a homemade Dacron ring. METHODS: All patients (2003-2020) operated for root aneurysm with/without aortic insufficiency (AI) were included. The standardized CAVIAAR (conservation aortique valvulaire dans les insuffisances aortiques et anévrysmes de la racine-Valve sparing in aortic insufficiencies and root aneurysms) technique was root remodeling and external annuloplasty ring with the EXTRA-AORTIC Ring or homemade Dacron ring. RESULTS: Among 486 patients (age 52.3 ± 14.0 years) operated for root aneurysm, 375 (repair rate: 77.1%) underwent root remodeling with annuloplasty (extra-aortic ring, n = 289, vs Dacron ring, n = 86). At 10 years (median follow-up, 4.08 years' interquartile range, 1.95-7.61), unmatched and matched analysis showed that patients with extra-aortic ring had greater survival, similar to the general population (93.3% vs 79.9%, P = .097), lower reoperation incidence (2.0% vs 9.7%, P = .0098), and lower AI grade >2 recurrence (1.9% vs 11.2%, P = .0042), compared with patients with a Dacron ring. Mixed-effect model showed that with extra-aortic ring annuloplasty, annular dilation over time (P = .0033) was prevented and, compared with the homemade Dacron ring, root expansibility was better preserved (3.22% vs 2.12%, P = .002) and mean transvalvular gradient was lower (6.58 mm Hg vs 7.94 mm Hg, P = .001). Tricuspid and bicuspid valves with extra-aortic ring had similar reoperation (4.3% vs 0.85%, P = .65) and AI grade >2 incidence (2.7% vs 1.2%, P = .61), expansibility (P = .29), and diameter (P = .47), whereas mean transvalvular gradient was lower for tricuspid valves (5.58 mm Hg vs 7.60 mm Hg, P = .004). CONCLUSIONS: Valve-sparing root remodeling with calibrated expansible extra-aortic ring annuloplasty improves the outcomes of reoperation and recurrent AI compared with a homemade Dacron ring. It prevents dilation and maintains physiological root dynamics for durable valve repair.

20.
Interv Cardiol Clin ; 13(2): 183-189, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432761

RESUMO

Mitral regurgitation (MR) is one of the most prevalent types of valvular heart disease and is expected to increase in the next decade. Transcatheter therapies for MR are constantly being developed and studied for use in this population. In this review, the author describes the phenotypes of functional or secondary mitral regurgitation, discusses the potential therapeutic targets for transcatheter intervention, and reviews the results of such technology in the literature.


Assuntos
Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Tecnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA