Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Anaerobe ; 61: 102133, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31813852

RESUMO

Cutibacterium acnes is a major etiologic agent of orthopaedic implant-associated infections (IAIs) and requires up to 14 days of incubation in an anaerobic atmosphere for growth detection. As blood culture (BC) systems are increasingly being used to monitor the growth of IAI specimens, we compared different BC media for growth detection of C. acnes. Non-duplicate C. acnes isolates (n = 99) obtained from sonicate-fluid cultures of orthopaedic IAIs from Slovenia (n = 54), conventional tissue samples of monomicrobial orthopaedic IAIs from France (n = 43) and two reference strains were inoculated to anaerobic BC bottles of two major BC systems and 3 conventional culture media types (thioglycolate broth, Schaedler and chocolate agar). Growth and time-to-detection (TTD) were recorded. Only Lytic (BACTEC) and SN (BacT/ALERT) bottles consistently detected growth of C. acnes within 14 days with 94% (n = 93) and 92% (n = 91) detection rates, respectively (p = 0.79). Lytic was superior to Plus BACTEC medium (p < 0.001), while SN was superior to all other BacT/ALERT media (p < 0.001). Mean TTD was 128 ± 43 h (61-336 h) for Lytic and 158 ± 65 h (77-336 h) for SN medium. Among the conventional media, 99% (n = 98) of the isolates grew on Schaedler agar, 96% (n = 95) in thioglycolate broth and 74% (n = 73) on chocolate agar. Inconsistent growth of C. acnes in different BC media can critically influence the detection of this major IAI pathogen. Only Lytic (BACTEC) and SN (BacT/ALERT) BC media types were consistently able to detect C. acnes within 14 days of incubation. However, visible growth was observed faster in thioglycolate broth and Schaedler agar media.


Assuntos
Infecções por Bactérias Gram-Positivas/diagnóstico , Infecções por Bactérias Gram-Positivas/microbiologia , Procedimentos Ortopédicos/efeitos adversos , Propionibacterium acnes , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Técnicas de Tipagem Bacteriana , Hemocultura , Humanos , Propionibacterium acnes/classificação , Propionibacterium acnes/isolamento & purificação
2.
J Clin Microbiol ; 57(2)2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30541938

RESUMO

The emergence of cell therapy programs in large academic centers has led to an increasing demand for clinical laboratories to assist with product sterility testing. Automated blood culture systems have shown promise as alternatives to the manual USP<71> compendial method, but current published data are limited by small organism test sets, particularly for molds. In 2015, failure of the Bactec FX system to detect mold contamination in two products prompted us to evaluate three test systems (compendial USP<71>, Bactec FX, and BacT/Alert Dual-T) over seven different culture combinations, using 118 challenge organisms representative of the NIH current good manufacturing practice (cGMP) environment. At <96 h and <144 h for bacterial and fungal detection, respectively, the compendial USP<71> method significantly outperformed the Bactec FX system (84.7% versus 64.4%; P = 0.0006) but not the BacT/Alert system at 32.5°C (78.8%; P = 0.3116). Extended incubation to 360 h with terminal visual inspection improved sensitivity, without a significant difference between compendial USP<71> and BacT/Alert testing (95.7% versus 89.0%; P = 0.0860); both systems were better than the Bactec FX system (71.2%; P < 0.0001 and P = 0.0003, respectively). The Bactec FX and BacT/Alert systems performed equivalently for 30 isolates derived from clinical bloodstream infections, confirming system optimization for clinical organisms rather than environmental contaminants. Paired Sabouraud dextrose agar (SDA) plates were always positive for fungi within the acceptable time frame. This study shows that the Bactec FX system is suboptimal for product sterility testing, and it provides strong data to support the use of BacT/Alert testing at 32.5°C paired with a supplemental SDA plate as an acceptable alternative to the compendial USP<71> method for product sterility testing.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/efeitos adversos , Contaminação de Medicamentos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/prevenção & controle , Técnicas Microbiológicas/métodos , Terapia Baseada em Transplante de Células e Tecidos/métodos , Sensibilidade e Especificidade
3.
J Infect Chemother ; 25(5): 404-406, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30685110

RESUMO

Blood cultures are the most valuable tool when bacteremia is clinically suspected. Technical advances have led to the development of automated blood culture systems to detect bacterial infections. Usually positive signals in automated blood culture systems result from the proliferation of microorganisms. Cases are classified as false-positive when the automated blood culture system produces a positive signal but no microorganisms are detected on Gram-stained smears and no microorganism growth is observed in blood subcultures. False-positive blood culture results are very rare in patients with hematologic malignancies. Recently, we encountered four patients who had false-positive blood culture results. Two of the patients were diagnosed with acute leukemia, involving hyperleukocytosis and an excess of blasts. The other two patients were diagnosed with acute leukemia and diffuse large B cell lymphoma with leukocytopenia. Although hypercapnia or acidosis, apart from hyperleukocytosis, might also cause false-positive results, our cases clearly did not have these conditions. We should be aware of the possibility that false-positive blood culture results can occur in patients with leukocytopenia, as well as hyperleukocytosis. To understand the mechanisms responsible for the observed false-positive results, additional studies are needed after the accumulation of similar cases.


Assuntos
Bacteriemia/diagnóstico , Técnicas Bacteriológicas/métodos , Hemocultura/métodos , Leucemia Mieloide Aguda/sangue , Linfoma Difuso de Grandes Células B/sangue , Adulto , Idoso , Automação Laboratorial , Bacteriemia/microbiologia , Hemocultura/instrumentação , Reações Falso-Positivas , Feminino , Humanos , Leucemia Mieloide Aguda/complicações , Linfoma Difuso de Grandes Células B/complicações , Masculino
4.
Indian J Crit Care Med ; 23(1): 27-30, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31065205

RESUMO

CONTEXT: Time to detection (TTD) given by continuous monitoring automated blood culture systems (CMABS) have been found to be a predictor of clinical outcome, drug resistance and type of microorganism in cases of bacteremia but the studies evaluating TTD with respect to fungemia are scarce especially from India. AIMS: To evaluate TTD for yeast isolates in fungal bloodstream infections with respect to the type of yeast isolates, risk factors and outcome and to study yeast susceptibility and distribution of yeast isolates with respect to patient population. MATERIALS AND METHODS: All blood culture specimens were processed in CMABS. The TTD for yeast isolates were recorded. The identification of yeast and susceptibility testing was done by automated methods. A correlation of TTD was done with respect to prior/concurrent yeast isolates, use of antifungal, risk factors and clinical outcome. RESULTS: Out of 80 yeast isolates, the maximum was C. parapsilosis (26.25%) followed by C. albicans (16.25%) and C. tropicalis (13.75%). A statistically significant difference in the occurrence of yeasts with early TTD (TTD < = 48 hours) and late TTD (TTD > 48 hours) was found. TTD of C. glabrata was significantly longer (p = 0.002) while TTD of C. tropicalis was significantly shorter (p = 0.013). There was an observable favorable outcome in shorter TTD (< = 48 hours). C. albicans and C. tropicalis depicted 100% susceptibility for Azoles, Amphotericin B and Echinocandins. CONCLUSION: TTD may be used as both diagnostic and prognostic adjunct in fungal bloodstream infections. This study is a step towards this novel approach. We also emphasize on the importance of speciation of yeast isolates and susceptibility testing. HOW TO CITE THIS ARTICLE: Butta H, Sardana R, Mendiratta L, Sibal A, Gupta V, Chawla R, Jafri AA. Time to Detection of Yeast Isolates in Pediatric and Adult Patients with Fungemia and its Relevance to Clinical Profile and Outcome. Indian Journal of Critical Care Medicine, January 2019;23(1):27-30.

5.
Acta Odontol Scand ; 76(5): 314-319, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29566581

RESUMO

OBJECTIVE: The purpose of this study is to investigate the effect of debonding procedures after completion of orthodontic treatments on bacteremia. MATERIALS AND METHODS: Twenty-eight patients who were treated with fixed orthodontic treatment at the Faculty of Dentistry's Department of Orthodontics at Gaziantep University and who had an indication of debonding were selected for this study, and blood samples were taken from these patients at different times and examined for bacteremia. Blood culture samples were taken from the antecubital veins of the patients prior to debonding (T0), immediately after removing the bracket (T1), and immediately after cleaning the composite residues and plaque deposits on the enamel surface (T2). The blood samples were then inoculated in blood culture bottles and investigated for bacterial growth. RESULTS: The results showed that there was no bacterial growth in the blood samples taken at T0 and T1, whereas 10 of the blood culture samples taken at T2 showed bacterial growth including the following bacteria; Streptococcus viridans, Streptococcus mitis, Streptococcus parasanguinis, Streptococcus salivarius, Streptococcus oralis, Staphylococcus aureus, Actinomyces oris, Actinomyces naeslundii and Klebsiella pneumoniae. CONCLUSION: It was concluded that patients in the risk group could develop bacteremia during debonding procedures. The presence of these bacteria in sterile blood suggested the possibility of bacterial endocarditis.


Assuntos
Bacteriemia/microbiologia , Descolagem Dentária/efeitos adversos , Placa Dentária/microbiologia , Aparelhos Ortodônticos/efeitos adversos , Assistência Odontológica , Feminino , Humanos , Masculino , Infecções Estreptocócicas/diagnóstico , Streptococcus/isolamento & purificação
6.
Anaerobe ; 35(Pt B): 92-5, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26254850

RESUMO

Recently new resin-based BacT/Alert FAN Plus bottles containing antibiotic-binding polymeric beads, were introduced as an improvement of the charcoal-based FAN bottles for the recovery of bacteria and fungi. To assess the performance of the novel anaerobic FN plus bottles in the detection of anaerobic organisms, we compared the detection rate and the time to detection (TTD) in spiked resin-based FN Plus bottles and charcoal-based FN bottles. The bottles were experimentally seeded with reference strains or clinical strains collected from positive blood cultures. Five reference strains and fifty-five clinically significant anaerobic isolates were investigated, of which 91% (61/67) showed growth in both types of bottles within an incubation time of 5 days. A significant prolonged median TTD of 45 h for anaerobic microorganisms was observed in the resin-based bottles versus 29 h in the charcoal-based bottles (P < 0.0001). Bacteroides spp., associated with higher virulence and higher mortality rates in bloodstream infections, were detected faster in the charcoal-based bottles as compared to the resin-based bottles. In conclusion recently improved resin FN bottles showed a significantly increased median TTD for the recovery of anaerobic isolates.


Assuntos
Bacteriemia/diagnóstico , Bactérias Anaeróbias/isolamento & purificação , Técnicas Bacteriológicas/métodos , Meios de Cultura/química , Manejo de Espécimes/métodos , Humanos , Sensibilidade e Especificidade , Fatores de Tempo
7.
Cytotherapy ; 16(5): 692-8, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24210785

RESUMO

BACKGROUND AIMS: Automated blood culture systems are widely used for the detection of microorganisms in cell therapy products. However, they are not validated by the manufacturers for this purpose. The aim of this study was to assess the ability of the Bactec system (Becton-Dickinson, Le Pont-De-Claix, France) to detect the microorganisms that could contaminate cell therapy products. METHODS: Three types of vials and conditions were tested: Plus Aerobic/F and Anaerobic/F media incubated at 35°C and Mycosis IC/F medium incubated at 30°C. All vials were incubated 10 days. We tested 18 microorganisms, including slow growers and some with fastidious nutritional requirements (10 bacteria, four yeasts, four filamentous fungi), each with four inocula (10-10(4) colony-forming units) performed in quintuplicate. RESULTS: The combination of Plus Aerobic/F and Plus Anaerobic/F vials detected all the tested pathogenic bacteria, all the tested Gram-positive skin commensal or environmental bacteria, all the tested yeasts, and three of four tested filamentous fungi. The addition of the Mycosis IC/F vial extended the range of detected microorganisms to one fungal environmental contaminant. Two bacterial environmental contaminants were not detected by our method. Low inocula of the skin contaminant Propionibacterium acnes were detected only after 7 days of incubation. CONCLUSIONS: These data suggest that (i) the prolongation of the incubation time of Plus Aerobic/F and Plus Anaerobic/F vials from 7 to 10 days and (ii) the use of Mycosis IC/F medium make minor contributions in the sterility testing of cell therapy products. We have validated the Bactec method using aerobic and anaerobic vials incubated 7 days at 35°C.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos/métodos , Meios de Cultura , Humanos , Esterilização/métodos
8.
EBioMedicine ; 101: 105004, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38350332

RESUMO

BACKGROUND: Bloodstream infections (BSI) pose a significant threat due to high mortality rates and the challenges posed by antimicrobial resistance (AMR). In 2019, an estimated 4.95 million deaths were linked to bacterial AMR. The highest impact was seen in resource-limited settings (RLS). For diagnosis of BSI, performant continuously-monitoring blood culture systems (CMBCS) have been optimized. However, in RLS, the implementation of CMBCS is hindered by budget constraints and unsuitable environmental conditions. Manufacturers from growing economies are currently producing affordable in vitro diagnostics, which could fill the gap in capacity, but so far these are not established outside their domestic markets. METHODS: This study evaluated the performance, usability, and interchangeability of Chinese CMBCS in a laboratory setting using simulated blood cultures with a panel of 20 BSI-associated strains. Four systems were selected for the assessment: Autobio BC60, Mindray TDR60, Scenker Labstar50, and DL-biotech DL-60. FINDINGS: Overall, all evaluated CMBCS demonstrated good performance with high yield (96.7-100%) and specificity (97.5-100%), comparable to the reference system (bioMérieux 3D). In addition, when used as "manual" blood cultures in a conventional incubator with visual growth detection, performance was also satisfactory: yield was between 90 and 100% and specificity was 100% for all BCBs. Both the CMBCS and the BCBs were easy to use and lot-to-lot variability in BCBs was minimal. The interchangeability testing indicated that the BCBs from different brands (all except Scenker) were compatible with the various automates, further highlighting the potential for a harmonized "universal BCB." INTERPRETATION: Based on this in vitro study, we recommend the use of these systems in settings with challenging environments and limited resources. The Autobio system performed best for automatic detection and DL-Biotech BCBs for manual cultures respectively (combination of performance, price, usability). The appropriateness for use in RLS should still be confirmed in a field study. FUNDING: The study was funded by FIND.


Assuntos
Hemocultura , Sepse , Humanos , Região de Recursos Limitados , Bactérias , Sepse/diagnóstico , China
9.
Int J Infect Dis ; 62: 1-5, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28625838

RESUMO

OBJECTIVES: The early detection of bacteraemia and fungemia is of paramount importance to guide antimicrobial therapy in septic patients. In this study the 'time to detection' (TTD) value for the new blood culture system BacT/ALERT VIRTUO (VIRTUO) was evaluated in 1462 positive clinical bottles and compared with the TTD for 1601 positive clinical bottles incubated in the BacT/ALERT 3D system (BTA-3D). METHODS: The most representative microorganisms isolated from bottles incubated in both blood culture systems were divided into eight categories (in order of frequency): coagulase-negative staphylococci (CoNS), Escherichia coli, Enterobacteriaceae (other than E. coli), Staphylococcus aureus, Enterococcus spp, viridans group streptococci, Pseudomonas aeruginosa, and Candida spp. RESULTS: The comparison of TTD values for the two blood culture systems strongly indicated that growth of the first five groups listed above was detected earlier with VIRTUO than with BTA-3D (p < 0.05). CONCLUSIONS: The new VIRTUO blood culture system can reduce the TTD for more than 75% of isolated microorganisms.


Assuntos
Hemocultura , Antibacterianos/uso terapêutico , Bacteriemia/diagnóstico , Bacteriemia/tratamento farmacológico , Técnicas Bacteriológicas , Candida/isolamento & purificação , Meios de Cultura , Enterobacteriaceae/isolamento & purificação , Escherichia coli/isolamento & purificação , Fungemia/diagnóstico , Humanos , Pseudomonas aeruginosa , Staphylococcus aureus/isolamento & purificação , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA