Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 555
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 288: 120523, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38278427

RESUMO

Although manganese (Mn) is a trace metal essential for humans, chronic exposure to Mn can cause accumulation of this metal ion in the brain leading to an increased risk of neurological and neurobehavioral health effects. This is a concern for welders exposed to Mn through welding fumes. While brain Mn accumulation in occupational settings has mostly been reported in the basal ganglia, several imaging studies also revealed elevated Mn in other brain areas. Since Mn functions as a magnetic resonance imaging (MRI) T1 contrast agent, we developed a whole-brain MRI approach to map in vivo Mn deposition differences in the brains of non-exposed factory controls and exposed welders. This is a cross-sectional analysis of 23 non-exposed factory controls and 36 exposed full-time welders from the same truck manufacturer. We collected high-resolution 3D MRIs of brain anatomy and R1 relaxation maps to identify regional differences using voxel-based quantification (VBQ) and statistical parametric mapping. Furthermore, we investigated the associations between excess Mn deposition and neuropsychological and motor test performance. Our results indicate that: (1) Using whole-brain MRI relaxometry methods we can generate excess Mn deposition maps in vivo, (2) excess Mn accumulation due to occupational exposure occurs beyond the basal ganglia in cortical areas associated with motor and cognitive functions, (3) Mn likely diffuses along white matter tracts in the brain, and (4) Mn deposition in specific brain regions is associated with exposure (cerebellum and frontal cortex) and motor metrics (cerebellum and hippocampus).


Assuntos
Manganês , Ferreiros , Humanos , Estudos Transversais , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Mapeamento Encefálico
2.
J Magn Reson Imaging ; 59(3): 784-796, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37466278

RESUMO

"Lung perfusion" in the context of imaging conventionally refers to the delivery of blood to the pulmonary capillary bed through the pulmonary arteries originating from the right ventricle required for oxygenation. The most important physiological mechanism in the context of imaging is the so-called hypoxic pulmonary vasoconstriction (HPV, also known as "Euler-Liljestrand-Reflex"), which couples lung perfusion to lung ventilation. In obstructive airway diseases such as asthma, chronic-obstructive pulmonary disease (COPD), cystic fibrosis (CF), and asthma, HPV downregulates pulmonary perfusion in order to redistribute blood flow to functional lung areas in order to conserve optimal oxygenation. Imaging of lung perfusion can be seen as a reflection of lung ventilation in obstructive airway diseases. Other conditions that primarily affect lung perfusion are pulmonary vascular diseases, pulmonary hypertension, or (chronic) pulmonary embolism, which also lead to inhomogeneity in pulmonary capillary blood distribution. Several magnetic resonance imaging (MRI) techniques either dependent on exogenous contrast materials, exploiting periodical lung signal variations with cardiac action, or relying on intrinsic lung voxel attributes have been demonstrated to visualize lung perfusion. Additional post-processing may add temporal information and provide quantitative information related to blood flow. The most widely used and robust technique, dynamic-contrast enhanced MRI, is available in clinical routine assessment of COPD, CF, and pulmonary vascular disease. Non-contrast techniques are important research tools currently requiring clinical validation and cross-correlation in the absence of a viable standard of reference. First data on many of these techniques in the context of observational studies assessing therapy effects have just become available. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 5.


Assuntos
Asma , Fibrose Cística , Infecções por Papillomavirus , Doença Pulmonar Obstrutiva Crônica , Humanos , Pulmão , Imageamento por Ressonância Magnética/métodos , Perfusão
3.
J Neurooncol ; 169(2): 445-455, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38913230

RESUMO

BACKGROUND AND OBJECTIVES: Contrast enhancement in glioblastoma, IDH-wildtype is common but not systematic. In the era of the WHO 2021 Classification of CNS Tumors, the prognostic impact of a contrast enhancement and the pattern of contrast enhancement is not clearly elucidated. METHODS: We performed an observational, retrospective, single-centre cohort study at a tertiary neurosurgical oncology centre (January 2006 - December 2022). We screened adult patients with a newly-diagnosed glioblastoma, IDH-wildtype in order to assess the prognosis role of the contrast enhancement and the pattern of contrast enhancement. RESULTS: We included 1149 glioblastomas, IDH-wildtype: 26 (2.3%) had a no contrast enhancement, 45 (4.0%) had a faint and patchy contrast enhancement, 118 (10.5%) had a nodular contrast enhancement, and 960 (85.5%) had a ring-like contrast enhancement. Overall survival was longer in non-contrast enhanced glioblastomas (26.7 months) than in contrast enhanced glioblastomas (10.9 months) (p < 0.001). In contrast enhanced glioblastomas, a ring-like pattern was associated with shorter overall survival than in faint and patchy and nodular patterns (10.0 months versus 13.0 months, respectively) (p = 0.033). Whatever the presence of a contrast enhancement and the pattern of contrast enhancement, surgical resection was an independent predictor of longer overall survival, while age ≥ 70 years, preoperative KPS score < 70, tumour volume ≥ 30cm3, and postoperative residual contrast enhancement were independent predictors of shorter overall survival. CONCLUSION: A contrast enhancement is present in the majority (97.7%) of glioblastomas, IDH-wildtype and, regardless of the pattern, is associated with a shorter overall survival. The ring-like pattern of contrast enhancement is typical in glioblastomas, IDH-wildtype (85.5%) and remains an independent predictor of shorter overall survival compared to other patterns (faint and patchy and nodular).


Assuntos
Neoplasias Encefálicas , Meios de Contraste , Glioblastoma , Isocitrato Desidrogenase , Imageamento por Ressonância Magnética , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/patologia , Glioblastoma/mortalidade , Glioblastoma/cirurgia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/mortalidade , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/cirurgia , Imageamento por Ressonância Magnética/métodos , Prognóstico , Isocitrato Desidrogenase/genética , Idoso , Adulto , Organização Mundial da Saúde
4.
Eur Radiol ; 34(3): 1755-1763, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658143

RESUMO

OBJECTIVES: To evaluate the diagnostic utility of multiphase postmortem CT angiography (PMCTA) to detect plaque enhancement as a surrogate marker of inflammation, using fatal coronary plaques obtained from autopsies following sudden cardiac death. METHODS: In this retrospective study, we included 35 cases (12 women, 34%; median [IQR] age, 52 [11] years), with autopsy-proven coronary thrombosis, histological examination, and multiphase PMCTA. Two radiologists blinded towards histological findings assessed PMCTA for plaque enhancement of the culprit lesion in consensus. Two forensic pathologists determined the culprit lesion and assessed histological samples in consensus. Cases with concomitant vasa vasorum density increase and intraplaque and periadventital inflammation were considered positive for plaque inflammation. Finally, we correlated radiology and pathology findings. RESULTS: All 35 cases had histological evidence of atherosclerotic plaque disruption and thrombosis; 30 (85.7%) had plaque inflammation. Plaque enhancement at multiphase PMCTA was reported in 21 (60%) and resulted in a PPV of 95.2% (77.3-99.2%) and an NPV of 28.6% (17-43.9%). Median histological ratings indicated higher intraplaque inflammation (p = .024) and vasa vasorum density (p = .032) in plaques with enhancement. We found no evidence of a difference in adventitial inflammation between CT-negative and CT-positive plaques (p = .211). CONCLUSIONS: Plaque enhancement was found in 2/3 of fatal atherothrombotic occlusions at coronary postmortem CT angiography. Furthermore, plaque enhancement correlated with histopathological plaque inflammation and increased vasa vasorum density. Plaque enhancement on multiphase CT angiography could potentially serve as a noninvasive marker of inflammation in high-risk populations. CLINICAL RELEVANCE STATEMENT: Phenotyping coronary plaque more comprehensively is one of the principal challenges cardiac imaging is facing. Translating our ex vivo findings of CT-based plaque inflammation assessment into clinical studies might help pave the way in defining high-risk plaque better. KEY POINTS: • Most thrombosed coronary plaques leading to fatality in our series had histological signs of inflammation. • Multiphase postmortem CT angiography can provide a noninvasive interrogation of plaque inflammation through contrast enhancement. • Atherosclerotic plaque enhancement at multiphase postmortem CT angiography correlated with histopathological signs of plaque inflammation and could potentially serve as an imaging biological marker of plaque vulnerability.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Feminino , Pessoa de Meia-Idade , Placa Aterosclerótica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X , Inflamação/diagnóstico por imagem , Autopsia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia
5.
J Cardiovasc Magn Reson ; 26(2): 101047, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38825155

RESUMO

BACKGROUND: Coronary artery wall contrast enhancement (CE) has been applied to non-invasive visualization of changes to the coronary artery wall in systemic lupus erythematosus (SLE). This study investigated the feasibility of quantifying CE to detect coronary involvement in IgG4-related disease (IgG4-RD), as well as the influence on disease activity assessment. METHODS: A total of 93 subjects (31 IgG4-RD; 29 SLE; 33 controls) were recruited in the study. Coronary artery wall imaging was performed in a 3.0 T MRI scanner. Serological markers and IgG4-RD Responder Index (IgG4-RD-RI) scores were collected for correlation analysis. RESULTS: Coronary wall CE was observed in 29 (94 %) IgG4-RD patients and 22 (76 %) SLE patients. Contrast-to-noise ratio (CNR) and total CE area were significantly higher in patient groups compared to controls (CNR: 6.1 ± 2.7 [IgG4-RD] v. 4.2 ± 2.3 [SLE] v. 1.9 ± 1.5 [control], P < 0.001; Total CE area: 3.0 [3.0-6.6] v. 1.7 [1.5-2.6] v. 0.3 [0.3-0.9], P < 0.001). In the IgG4-RD group, CNR and total CE area were correlated with the RI (CNR: r = 0.55, P = 0.002; total CE area: r = 0.39, P = 0.031). RI´ scored considering coronary involvement by CE, differed significantly from RI scored without consideration of CE (RI v. RI´: 15 ± 6 v. 16 ± 6, P < 0.001). CONCLUSIONS: Visualization and quantification of CMR coronary CE by CNR and total CE area could be utilized to detect subclinical and clinical coronary wall involvement, which is prevalent in IgG4-RD. The potential inclusion of small and medium-sized vessel involvements in the assessment of disease activity in IgG4-RD is worthy of further investigation.

6.
BMC Pregnancy Childbirth ; 24(1): 22, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172701

RESUMO

OBJECTIVE: To explore the feasibility of the golden-angle radial sparse parallel (GRASP) dynamic magnetic resonance imaging (MRI) technique in predicting the intraoperative bleeding risk of scar pregnancy. METHODS: A total of 49 patients with cesarean scar pregnancy (CSP) who underwent curettage and GRASP-MRI imaging were retrospectively selected between January 2021 and July 2022. The pharmacokinetic parameters, including Wash-in, Wash-out, time to peck (TTP), initial area under the curve (iAUC), the transfer rate constant (Ktrans), constant flow rate (Kep), and volume of extracellular space (Ve), were calculated. The amount of intraoperative bleeding was recorded by a gynecologist who performed surgery, after which patients were divided into non-hemorrhage (blood loss ≤ 200 mL) and hemorrhage (blood loss > 200 mL) groups. The measured pharmacokinetic parameters were statistically compared using the t-test or Mann-Whitney U test with a significant level set to be p < 0.05. The receiver operating characteristic (ROC) curve was constructed, and the area under the curve (AUC) was calculated to evaluate each parameter's capability in intraoperative hemorrhage subgroup classification. RESULTS: Twenty patients had intraoperative hemorrhage (blood loss > 200 mL) during curettage. The hemorrhage group had larger Wash-in, iAUC, Ktrans, Ve, and shorter TTP than the non-hemorrhage group (all P > 0.05). Wash-in had the highest AUC value (0.90), while Ktrans had the lowest value (0.67). Wash-out and Kep were not significantly different between the two groups. CONCLUSION: GRASP DCE-MRI has the potential to forecast intraoperative hemorrhage during curettage treatment of CSP, with Wash-in exhibiting the highest predictive performance. This data holds promise for advancing personalized treatment. However, further study is required to compare its effectiveness with other risk factors identified through anatomical MRI and ultrasound.


Assuntos
Cicatriz , Gravidez Ectópica , Gravidez , Feminino , Humanos , Estudos Retrospectivos , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Cicatriz/cirurgia , Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Gravidez Ectópica/diagnóstico por imagem , Gravidez Ectópica/etiologia , Gravidez Ectópica/cirurgia , Perda Sanguínea Cirúrgica , Curetagem
7.
BMC Med Imaging ; 24(1): 193, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39080580

RESUMO

RATIONALE AND OBJECTIVE: To investigate the impact of the contrast enhancement boost (CE-boost) technique on the image quality of CT angiography (CTA) derived from 80-kVp cerebral CT perfusion (CTP) data, and to compare it with conventional CTApeak as well as other currently employed methods for enhancing CTA images, such as CTAtMIP and CTAtAve extracted from CTP. MATERIALS AND METHODS: The data of forty-seven patients who underwent CTP at 80 kVp were retrospectively collected. Four sets of images: CTApeak, CTAtMIP, CTAtAve, and CE-boost images. The CTApeak image represents the arterial phase at its peak value, captured as a single time point. CTAtMIP and CTAtAve are 4D CTA images that provide maximum density projection and average images from the three most prominent time points. CE-boost is a postprocessing technique used to enhance contrast in the arterial phase at its peak value. We compared the average CT value, standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the internal carotid artery (ICA) and basilar artery (BA) among the four groups. Image quality was evaluated using a 5-point scale. RESULTS: The CE-boost demonstrated and CNR in the ICA and BA (all p < 0.001). Compared with the other three CTA reconstructed images, the CE-boost images had the best subjective image quality, with the highest scores of 4.77 ± 0.43 and 4.87 ± 0.34 for each reader (all p < 0.001). CONCLUSION: Compared with other currently used techniques,CE-boost enhances the image quality of CTA derived from 80-kVp CTP data, leading to improved visualization of intracranial arteries.


Assuntos
Angiografia por Tomografia Computadorizada , Meios de Contraste , Razão Sinal-Ruído , Humanos , Angiografia por Tomografia Computadorizada/métodos , Feminino , Masculino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Angiografia Cerebral/métodos , Adulto , Idoso de 80 Anos ou mais , Intensificação de Imagem Radiográfica/métodos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Basilar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
BMC Med Imaging ; 24(1): 163, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38956583

RESUMO

PURPOSE: To examine whether there is a significant difference in image quality between the deep learning reconstruction (DLR [AiCE, Advanced Intelligent Clear-IQ Engine]) and hybrid iterative reconstruction (HIR [AIDR 3D, adaptive iterative dose reduction three dimensional]) algorithms on the conventional enhanced and CE-boost (contrast-enhancement-boost) images of indirect computed tomography venography (CTV) of lower extremities. MATERIALS AND METHODS: In this retrospective study, seventy patients who underwent CTV from June 2021 to October 2022 to assess deep vein thrombosis and varicose veins were included. Unenhanced and enhanced images were reconstructed for AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images were obtained using subtraction software. Objective and subjective image qualities were assessed, and radiation doses were recorded. RESULTS: The CT values of the inferior vena cava (IVC), femoral vein ( FV), and popliteal vein (PV) in the CE-boost images were approximately 1.3 (1.31-1.36) times higher than in those of the enhanced images. There were no significant differences in mean CT values of IVC, FV, and PV between AIDR 3D and AiCE, AIDR 3D-boost and AiCE-boost images. Noise in AiCE, AiCE-boost images was significantly lower than in AIDR 3D and AIDR 3D-boost images ( P < 0.05). The SNR (signal-to-noise ratio), CNR (contrast-to-noise ratio), and subjective scores of AiCE-boost images were the highest among 4 groups, surpassing AiCE, AIDR 3D, and AIDR 3D-boost images (all P < 0.05). CONCLUSION: In indirect CTV of the lower extremities images, DLR with the CE-boost technique could decrease the image noise and improve the CT values, SNR, CNR, and subjective image scores. AiCE-boost images received the highest subjective image quality score and were more readily accepted by radiologists.


Assuntos
Meios de Contraste , Aprendizado Profundo , Extremidade Inferior , Flebografia , Humanos , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Idoso , Flebografia/métodos , Adulto , Algoritmos , Trombose Venosa/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Veia Poplítea/diagnóstico por imagem , Varizes/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Veia Femoral/diagnóstico por imagem , Doses de Radiação , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Intensificação de Imagem Radiográfica/métodos
9.
Acta Radiol ; : 2841851241262765, 2024 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-39033390

RESUMO

BACKGROUND: The best settings of deep learning image reconstruction (DLIR) algorithm for abdominal low-kiloelectron volt (keV) virtual monoenergetic imaging (VMI) have not been determined. PURPOSE: To determine the optimal settings of the DLIR algorithm for abdominal low-keV VMI. MATERIAL AND METHODS: The portal-venous phase computed tomography (CT) scans of 109 participants with 152 lesions were reconstructed into four image series: VMI at 50 keV using adaptive statistical iterative reconstruction (Asir-V) at 50% blending (AV-50); and VMI at 40 keV using AV-50 and DLIR at medium (DLIR-M) and high strength (DLIR-H). The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of nine anatomical sites were calculated. Noise power spectrum (NPS) using homogenous region of liver, and edge rise slope (ERS) at five edges were measured. Five radiologists rated image quality and diagnostic acceptability, and evaluated the lesion conspicuity. RESULTS: The SNR and CNR values, and noise and noise peak in NPS measurements, were significantly lower in DLIR images than AV-50 images in all anatomical sites (all P < 0.001). The ERS values were significantly higher in 40-keV images than 50-keV images at all edges (all P < 0.001). The differences of the peak and average spatial frequency among the four reconstruction algorithms were significant but relatively small. The 40-keV images were rated higher with DLIR-M than DLIR-H for diagnostic acceptance (P < 0.001) and lesion conspicuity (P = 0.010). CONCLUSION: DLIR provides lower noise, higher sharpness, and more natural texture to allow 40 keV to be a new standard for routine VMI reconstruction for the abdomen and DLIR-M gains higher diagnostic acceptance and lesion conspicuity rating than DLIR-H.

10.
Proc Natl Acad Sci U S A ; 118(29)2021 07 20.
Artigo em Inglês | MEDLINE | ID: mdl-34266949

RESUMO

The perception of sensory events can be enhanced or suppressed by the surrounding spatial and temporal context in ways that facilitate the detection of novel objects and contribute to the perceptual constancy of those objects under variable conditions. In the auditory system, the phenomenon known as auditory enhancement reflects a general principle of contrast enhancement, in which a target sound embedded within a background sound becomes perceptually more salient if the background is presented first by itself. This effect is highly robust, producing an effective enhancement of the target of up to 25 dB (more than two orders of magnitude in intensity), depending on the task. Despite the importance of the effect, neural correlates of auditory contrast enhancement have yet to be identified in humans. Here, we used the auditory steady-state response to probe the neural representation of a target sound under conditions of enhancement. The probe was simultaneously modulated in amplitude with two modulation frequencies to distinguish cortical from subcortical responses. We found robust correlates for neural enhancement in the auditory cortical, but not subcortical, responses. Our findings provide empirical support for a previously unverified theory of auditory enhancement based on neural adaptation of inhibition and point to approaches for improving sensory prostheses for hearing loss, such as hearing aids and cochlear implants.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva , Estimulação Acústica , Adolescente , Adulto , Limiar Auditivo , Comportamento , Eletroencefalografia , Feminino , Audição , Humanos , Masculino , Som , Adulto Jovem
11.
Pediatr Radiol ; 54(8): 1315-1324, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-38839610

RESUMO

BACKGROUND: Low-iodine-dose computed tomography (CT) protocols have emerged to mitigate the risks associated with contrast injection, often resulting in decreased image quality. OBJECTIVE: To evaluate the image quality of low-iodine-dose CT combined with an artificial intelligence (AI)-based contrast-boosting technique in abdominal CT, compared to a standard-iodine-dose protocol in children. MATERIALS AND METHODS: This single-center retrospective study included 35 pediatric patients (mean age 9.2 years, range 1-17 years) who underwent sequential abdominal CT scans-one with a standard-iodine-dose protocol (standard-dose group, Iobitridol 350 mgI/mL) and another with a low-iodine-dose protocol (low-dose group, Iohexol 240 mgI/mL)-within a 4-month interval from January 2022 to July 2022. The low-iodine CT protocol was reconstructed using an AI-based contrast-boosting technique (contrast-boosted group). Quantitative and qualitative parameters were measured in the three groups. For qualitative parameters, interobserver agreement was assessed using the intraclass correlation coefficient, and mean values were employed for subsequent analyses. For quantitative analysis of the three groups, repeated measures one-way analysis of variance with post hoc pairwise analysis was used. For qualitative analysis, the Friedman test followed by post hoc pairwise analysis was used. Paired t-tests were employed to compare radiation dose and iodine uptake between the standard- and low-dose groups. RESULTS: The standard-dose group exhibited higher attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of organs and vessels compared to the low-dose group (all P-values < 0.05 except for liver SNR, P = 0.12). However, noise levels did not differ between the standard- and low-dose groups (P = 0.86). The contrast-boosted group had increased attenuation, CNR, and SNR of organs and vessels, and reduced noise compared with the low-dose group (all P < 0.05). The contrast-boosted group showed no differences in attenuation, CNR, and SNR of organs and vessels (all P > 0.05), and lower noise (P = 0.002), than the standard-dose group. In qualitative analysis, the contrast-boosted group did not differ regarding vessel enhancement and lesion conspicuity (P > 0.05) but had lower noise (P < 0.05) and higher organ enhancement and artifacts (all P < 0.05) than the standard-dose group. While iodine uptake was significantly reduced in low-iodine-dose CT (P < 0.001), there was no difference in radiation dose between standard- and low-iodine-dose CT (all P > 0.05). CONCLUSION: Low-iodine-dose abdominal CT, combined with an AI-based contrast-boosting technique exhibited comparable organ and vessel enhancement, as well as lesion conspicuity compared to standard-iodine-dose CT in children. Moreover, image noise decreased in the contrast-boosted group, albeit with an increase in artifacts.


Assuntos
Inteligência Artificial , Meios de Contraste , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Criança , Feminino , Masculino , Meios de Contraste/administração & dosagem , Pré-Escolar , Tomografia Computadorizada por Raios X/métodos , Lactente , Adolescente , Iohexol/administração & dosagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos
12.
Skeletal Radiol ; 53(2): 263-273, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37400604

RESUMO

OBJECTIVE: The aims of our study were to analyze agreement among readers with different levels of expertise and diagnostic performance of individual and combined imaging signs for the diagnosis of adhesive capsulitis of the shoulder. METHODS: In a retrospective study, contrast-enhanced shoulder MRIs of 60 patients with and 120 without clinically diagnosed adhesive capsulitis were evaluated by three readers independently. As non-enhanced imaging signs, readers evaluated signal intensity and thickness of the axillary recess capsule, thickness of the rotator interval capsule and the coracohumeral ligament as well as obliteration of subcoracoid fat. Furthermore, contrast enhancement of axillary recess and rotator interval capsule were evaluated. Data analysis included interreader reliability, ROC analysis, and logistic regression (p < 0.05). RESULTS: Contrast-enhanced parameters showed substantially higher agreement among readers (ICC 0.79-0.80) than non-enhanced parameters (0.37-0.45). AUCs of contrast-enhanced signs (95.1-96.6%) were significantly higher (p < 0.01) than of non-enhanced imaging signs (61.5-85.9%) when considered individually. Combined evaluation of axillary recess signal intensity and thicknesses of axillary recess or rotator interval-when at least one of two signs was rated positive-increased accuracy compared to individual imaging signs, however not statistically significant. CONCLUSION: Contrast-enhanced imaging signs show both distinctly higher agreement among readers and distinctly higher diagnostic performance compared to non-enhanced imaging signs based on the imaging protocol used in this study. Combined evaluation of parameters showed a tendency to increase discrimination; however, the effect on diagnosis of ACS was not statistically significant.


Assuntos
Bursite , Articulação do Ombro , Humanos , Ombro , Estudos Retrospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Articulação do Ombro/diagnóstico por imagem , Bursite/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
13.
Sensors (Basel) ; 24(12)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38931613

RESUMO

In the autonomous driving industry, there is a growing trend to employ long-wave infrared (LWIR)-based uncooled thermal-imaging cameras, capable of robustly collecting data even in extreme environments. Consequently, both industry and academia are actively researching contrast-enhancement techniques to improve the quality of LWIR-based thermal-imaging cameras. However, most research results only showcase experimental outcomes using mass-produced products that already incorporate contrast-enhancement techniques. Put differently, there is a lack of experimental data on contrast enhancement post-non-uniformity (NUC) and temperature compensation (TC) processes, which generate the images seen in the final products. To bridge this gap, we propose a histogram equalization (HE)-based contrast enhancement method that incorporates a region-based clipping technique. Furthermore, we present experimental results on the images obtained after applying NUC and TC processes. We simultaneously conducted visual and qualitative performance evaluations on images acquired after NUC and TC processes. In the visual evaluation, it was confirmed that the proposed method improves image clarity and contrast ratio compared to conventional HE-based methods, even in challenging driving scenarios such as tunnels. In the qualitative evaluation, the proposed method demonstrated upper-middle-class rankings in both image quality and processing speed metrics. Therefore, our proposed method proves to be effective for the essential contrast enhancement process in LWIR-based uncooled thermal-imaging cameras intended for autonomous driving platforms.

14.
Breast Cancer Res ; 25(1): 87, 2023 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-37488621

RESUMO

Deep learning analysis of radiological images has the potential to improve diagnostic accuracy of breast cancer, ultimately leading to better patient outcomes. This paper systematically reviewed the current literature on deep learning detection of breast cancer based on magnetic resonance imaging (MRI). The literature search was performed from 2015 to Dec 31, 2022, using Pubmed. Other database included Semantic Scholar, ACM Digital Library, Google search, Google Scholar, and pre-print depositories (such as Research Square). Articles that were not deep learning (such as texture analysis) were excluded. PRISMA guidelines for reporting were used. We analyzed different deep learning algorithms, methods of analysis, experimental design, MRI image types, types of ground truths, sample sizes, numbers of benign and malignant lesions, and performance in the literature. We discussed lessons learned, challenges to broad deployment in clinical practice and suggested future research directions.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Imageamento por Ressonância Magnética , Algoritmos , Espectroscopia de Ressonância Magnética
15.
J Magn Reson Imaging ; 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37950398

RESUMO

BACKGROUND: The widely used magnetization-prepared rapid gradient-echo (MPRAGE) sequence makes enhancing lesions and blood vessels appear bright after gadolinium administration. However, dark blood imaging using T1-weighted Sampling Perfection with Application optimized Contrast using different flip angle Evolution (T1 SPACE) can be advantageous since it improves the conspicuity of small metastases and leptomeningeal disease. As a potential alternative to T1 SPACE, we evaluated a new dark blood sequence called echo-uT1 RESS (unbalanced T1 Relaxation-Enhanced Steady-State). PURPOSE: We compared the performance of echo-uT1 RESS with Dixon fid-uT1 RESS, MPRAGE, and T1 SPACE. STUDY TYPE: Retrospective, IRB approved. SUBJECTS/PHANTOM: Phantom to assess flow properties of echo-uT1 RESS. Twenty-one patients (14 female, age range 35-82 years) with primary and secondary brain tumors. FIELD STRENGTH/SEQUENCES: 3 Tesla/MPRAGE, T1 SPACE, Dixon fid-uT1 RESS, echo-uT1 RESS. ASSESSMENT: Flow phantom signal vs. velocity as a function of flip angle and sequence. Qualitative image assessment on 4-point scale. Quantitative evaluation of tumor-to-brain contrast, apparent contrast-to-noise ratio (aCNR), and vessel-to-brain aCNR. STATISTICAL TESTS: Friedman and Mann-Whitney U tests. A P value <0.05 was considered statistically significant. RESULTS: In the phantom, echo-uT1 RESS showed greater flow-dependent signal loss than fid-uT1 RESS. In patients, blood vessels appeared bright with MPRAGE, gray with fid-uT1 RESS, and dark with T1 SPACE and echo-uT1 RESS. For MPRAGE, Dixon fid-uT1 RESS, echo-uT1 RESS, and T1 SPACE, respective tumor-to-brain contrast values were 0.6 ± 0.3, 1.3 ± 0.5, 1.0 ± 0.4, and 0.6 ± 0.4, while normalized aCNR values were 68.9 ± 50.9, 128.4 ± 59.2, 74.2 ± 42.1, and 99.4 ± 73.9. DATA CONCLUSION: Volumetric dark blood contrast-enhanced brain MRI is feasible using echo-uT1 RESS. The dark blood effect was improved vs. fid-uT1 RESS, while both uT1 RESS versions provided better tumor-to-brain contrast than MPRAGE. Whereas T1 SPACE provided better tumor aSNR, echo-uT1 RESS provided better Weber contrast, lesion sharpness and a more consistent dark blood effect. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 1.

16.
J Neurooncol ; 162(3): 489-501, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36598613

RESUMO

PURPOSE: Proton beam radiotherapy (PRT) has been demonstrated to improve neurocognitive sequelae particularly. Nevertheless, following PRT, increased rates of radiation-induced contrast enhancements (RICE) are feared. How safe and effective is PRT for IDH-mutated glioma WHO grade 2 and 3? METHODS: We analyzed 194 patients diagnosed with IDH-mutated WHO grade 2 (n = 128) and WHO grade 3 (n = 66) glioma who were treated with PRT from 2010 to 2020. Serial clinical and imaging follow-up was performed for a median of 5.1 years. RESULTS: For WHO grade 2, 61% were astrocytoma and 39% oligodendroglioma while for WHO grade 3, 55% were astrocytoma and 45% oligodendroglioma. Median dose for IDH-mutated glioma was 54 Gy(RBE) [range 50.4-60 Gy(RBE)] for WHO grade 2 and 60 Gy(RBE) [range 54-60 Gy(RBE)] for WHO grade 3. Five year overall survival was 85% in patients with WHO grade 2 and 67% in patients with WHO grade 3 tumors. Overall RICE risk was 25%, being higher in patients with WHO grade 2 (29%) versus in patients with WHO grade 3 (17%, p = 0.13). RICE risk increased independent of tumor characteristics with older age (p = 0.017). Overall RICE was symptomatic in 31% of patients with corresponding CTCAE grades as follows: 80% grade 1, 7% grade 2, 13% grade 3, and 0% grade 3 + . Overall need for RICE-directed therapy was 35%. CONCLUSION: These data demonstrate the effectiveness of PRT for IDH-mutated glioma WHO grade 2 and 3. The RICE risk differs with WHO grading and is higher in older patients with IDH-mutated Glioma WHO grade 2 and 3.


Assuntos
Astrocitoma , Neoplasias Encefálicas , Glioma , Oligodendroglioma , Humanos , Idoso , Oligodendroglioma/patologia , Prótons , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/patologia , Glioma/genética , Glioma/radioterapia , Astrocitoma/patologia , Organização Mundial da Saúde , Isocitrato Desidrogenase/genética , Mutação
17.
Eur J Neurol ; 30(8): 2393-2400, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37183506

RESUMO

BACKGROUND: The presence of contrast enhancement (CE) on magnetic resonance imaging (MRI) is one of the principal criteria for diagnosis and disease activity of multiple sclerosis (MS). Therefore, MS patients are frequently exposed to contrast agents, which may cause deposition in the brain, restricting its use in repeat examinations. Thus, serum biomarkers may be valuable as surrogate parameters to evaluate MS activity. METHODS: REDUCE-GAD was a prospective, multicentric, biobanking study to determine whether established serum markers (neurofilament light chain [NfL], glial fibrillary acidic protein [GFAP], tau protein, ubiquitin-carboxyl-terminal-hydrolase (UCH-L1), S100B and matrix-metalloproteinase 9 [MMP9]) are predictive of CE-positive MRI lesions. Blood samples were obtained from patients undergoing MRI 5 days before or after collection. RESULTS: Patients (N = 102) from four different centers with confirmed MS or related disorders were included; n = 57 (55.9%) showed CE on MRI versus n = 45 (44.1%) without CE. Only higher NfL values indicated CE (odds ratio [OR] 1.05; 95% CI 1.0-1.09) and were correlated with number (ρ = 0.47; p < 0.001) and diameter of CE lesions (ρ = 0.58; p < 0.001). Nfl Z-scores improved diagnostic accuracy (OR 1.52; 95% CI 1.06-2.18). Receiver operator characteristic analysis revealed a reasonable cut-off value for NfL at 14.1 pg/mL (sensitivity 49.1%; specificity 82.2%; positive predictive value 77.8%; negative predictive value 56.0%). NfL ≥59.2 pg/mL was exclusively observed in patients with CE. CONCLUSIONS: Evaluation of several possible serum biomarkers for CE in MS patients provided the most robust results for NfL, particularly as Z-scores. Following further evaluation, biomarkers may help stratify the application of contrast agents for brain imaging in MS patients.


Assuntos
Esclerose Múltipla , Humanos , Esclerose Múltipla/diagnóstico por imagem , Gadolínio , Estudos Prospectivos , Bancos de Espécimes Biológicos , Meios de Contraste , Biomarcadores , Proteína Glial Fibrilar Ácida , Proteínas de Neurofilamentos
18.
Neuroradiology ; 65(7): 1133-1141, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36995375

RESUMO

PURPOSE: Sampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE). Our study aims to (i) evaluate the diagnostic accuracy of SPACE compared to its use in combination with VIBE, (ii) investigate the effect of radiologist's experience in the sequence's performance, and (iii) analyze causes of discordants results. METHODS: Four hundred seventy-three 3T MRI scans were retrospectively analyzed following a monocentric study design. Two studies were formed: one including SPACE alone and one combining both sequences (SPACE + VIBE, the reference). An experienced neuroradiologist and a radiology trainee independently reviewed the images of each study and reported the number of brain metastases. The sensitivity (Se) and specificity (Sp) of SPACE compared to SPACE + VIBE in metastases detection were reported. Diagnostic accuracy of SPACE compared to SPACE + VIBE was assessed by using McNemar's test. Significance was set at p < 0.05. Cohen's kappa was used for inter-method and inter-observer variability. RESULTS: No significant difference was found between the two methods, with SPACE having a Se > 93% and a Sp > 87%. No effect of readers' experience was disclosed. CONCLUSION: Independently of radiologist's experience, SPACE alone is robust enough to replace SPACE + VIBE for brain metastases detection.


Assuntos
Neoplasias Encefálicas , Imageamento Tridimensional , Humanos , Estudos Retrospectivos , Fluxo de Trabalho , Imageamento Tridimensional/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
19.
Acta Radiol ; 64(6): 2111-2117, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37046385

RESUMO

BACKGROUND: Low attenuation volume percentage (LAV%) has been identified as a quantitative imaging biomarker for emphysema with good correlation with spirometry. The influence of intravenous contrast agent on LAV% and its correlation with spirometry is not well known. PURPOSE: To evaluate the influence of intravenous contrast agent on artificial intelligence (AI)-based LAV% in correlation with spirometric Tiffeneau-Pinelli Index (TI). MATERIAL AND METHODS: In a retrospective study, two groups of 47 patients (mean age 68.04 ± 12.64 and 67.89 ± 11.54 years) with either non-enhanced chest computed tomography (CT) or contrast-enhanced CT were compared. Using an AI-based software, LAV% was quantified using a threshold <-950 HU. TI was calculated from spirometry and pathologic airway obstruction was considered with a TI <70. The effect of contrast agent on LAV% and the relationship between TI and LAV% was analyzed. Correlation coefficients between TI and LAV% were compared for both groups. RESULTS: Patients with non-enhanced CT had a mean LAV% of 9.07 ± 7.53. Of them, 22 patients had a TI <70% and 25 patients a TI ≥70%. Patients with contrast-enhanced CT had a mean LAV% of 6.54 ± 4.62. Of them, 20 patients had a TI <70% and 27 patients had a TI ≥70%. Contrast agent did not show a major effect on LAV% (P = 0.099) and the relationship between TI and LAV% (P = 0.88). In both groups, a significant correlation between TI and LAV% was found (ρ = -0.317 for non-enhanced CT; ρ = -0.514 for contrast-enhanced CT). Difference between correlation coefficients was insignificant. CONCLUSION: Our findings suggest that contrast agent does not influence LAV% nor its correlation with TI.


Assuntos
Meios de Contraste , Pulmão , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Inteligência Artificial , Tomografia Computadorizada por Raios X/métodos
20.
Sensors (Basel) ; 23(5)2023 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-36904700

RESUMO

The dynamic range of an X-ray digital imaging system is very important when detecting objects with a high absorption ratio. In this paper, a ray source filter is used to filter the low-energy ray components which have no penetrating power to the high absorptivity object to reduce the X-ray integral intensity. This enables the effective imaging of the high absorptivity objects and avoids the image saturation of low absorptivity objects, thus achieving single exposure imaging of high absorption ratio objects. However, this method will reduce the image contrast and weaken the image structure information. Therefore, this paper proposes a contrast enhancement method for X-ray images based on Retinex. Firstly, based on Retinex theory, the multi-scale residual decomposition network decomposes the image into an illumination component and a reflection component. Then, the contrast of the illumination component is enhanced through the U-Net model with the global-local attention mechanism, and the reflection component is enhanced in detail using the anisotropic diffused residual dense network. Finally, the enhanced illumination component and the reflected component are fused. The results show that the proposed method can effectively enhance the contrast in X-ray single exposure images of the high absorption ratio objects, and can fully display the structure information of images on devices with low dynamic range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA