1.
Eur J Radiol Open ; 10: 100470, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36590327

RESUMO

Rationale and objectives: Patients receiving high cumulative effective doses (CED) from recurrent computed tomography (CT) in a real-life setting are not well identified. Evaluation of causes and patient characteristics may help to define individuals potentially at risk of radiation-induced secondary malignancies. Materials and methods: Patients who received a CED > 100 mSv from CT scans during October 2012 and April 2020 at a tertiary university center were identified with the help of a radiological radiation dose monitoring system. The primary disease and referral diagnosis, number of CT exams, time period, age, BMI and gender distribution of the 1000 patients with the highest CED were analysed. Results: 3431 patients had a CED of more than 100 mSv, which corresponded to 2.75% of all patients who received a CT exam. From the 1000 patients with the highest CED, mean number of CT exams per patient was 14.6, mean CED was 257 mSv (SD 98, range 177-1339). Mean age of patients was 63.9 years (SD 10.6), male to female ratio 3:2, and mean BMI 28.7 kg/m2 (SD 5.5). 728 (72.9%) patients had cancer. The leading primary diagnosis was liver cirrhosis in 197 patients and 103 patients had a liver transplantation. In patients with liver cirrhosis, 750 exams were indicated for the follow-up of the disease, 662 for the clarification of an acute clinical condition, and 202 for CT-guided stereotactic radiofrequency ablation. Conclusion: Recurrent CT scans of patients with cancer, liver cirrhosis and liver transplantation may lead to critically high CED.

2.
Eur J Radiol Open ; 10: 100479, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36819113

RESUMO

Purpose: Conventional computed tomography (CT) images are severely affected by metal artifacts in patients with intracranial coils. Monoenergetic images have been suggested to reduce metal artifacts.The aim of this study was to assess metal artifacts in virtual monoenergetic images (VMIs) reconstructed from spectral brain CT. Methods: Thirty-two consecutive patients with intracranial coils examined by spectral non contrast brain CT (NCCT) at our center between November 2017 and April 2019 were included. Attenuation and standard deviations were measured in regions of interest (ROIs) at predefined areas in artifact-free and artifact-affected areas. Measurements were performed in conventional polyenergetic images (CIs) and the corresponding data for VMIs were retrieved through spectral diagrams for the each ROI. Subjective analysis was performed by visual grading of CIs and specific VMIs by two neuroradiologists, independently. Results: In artefact-affected image areas distal from the metal objects, the attenuation values decreased with higher energy level VMIs. The same effect was not seen for artefact-affected image areas close to the metal.Subjective rating of the artefact severity was significantly better in VMIs at 50 keV for one of the two reviewers compared to the CIs. Overall image quality and tissue differentiation scores were significantly higher for both reviewers in VMIs at 60 and 70 keV compared to CIs. Conclusion: Our quantitative and qualitative image analysis shown that there is a small significant reduction of intracranial coils artifacts severity by all monoenergetic reconstructions from 50 to 200 keV with preserved or increased overall subjective image quality compared to conventional images.

3.
Eur J Radiol Open ; 10: 100459, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36561422

RESUMO

Purpose: To assess the potential of radiomic features in comparison to dual-energy CT (DECT) material decomposition to objectively stratify abdominal lymph node metastases. Materials and methods: In this retrospective study, we included 81 patients (m, 57; median age, 65 (interquartile range, 58.7-73.3) years) with either lymph node metastases (n = 36) or benign lymph nodes (n = 45) who underwent contrast-enhanced abdominal DECT between 06/2015-07/2019. All malignant lymph nodes were classified as unequivocal according to RECIST criteria and confirmed by histopathology, PET-CT or follow-up imaging. Three investigators segmented lymph nodes to extract DECT and radiomics features. Intra-class correlation analysis was applied to stratify a robust feature subset with further feature reduction by Pearson correlation analysis and LASSO. Independent training and testing datasets were applied on four different machine learning models. We calculated the performance metrics and permutation-based feature importance values to increase interpretability of the models. DeLong test was used to compare the top performing models. Results: Distance matrices and t-SNE plots revealed clearer clusters using a combination of DECT and radiomic features compared to DECT features only. Feature reduction by LASSO excluded all DECT features of the combined feature cohort. The top performing radiomic features model (AUC = 1.000; F1 = 1.000; precision = 1.000; Random Forest) was significantly superior to the top performing DECT features model (AUC = 0.942; F1 = 0.762; precision = 0.800; Stochastic Gradient Boosting) (DeLong < 0.001). Conclusion: Imaging biomarkers have the potential to stratify unequivocal lymph node metastases. Radiomics models were superior to DECT material decomposition and may serve as a support tool to facilitate stratification of abdominal lymph node metastases.

4.
JHEP Rep ; 3(4): 100323, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34355155

RESUMO

BACKGROUND & AIMS: Retrospective cross-sectional studies linked sarcopenia and myosteatosis with metabolic dysfunction-associated fatty liver disease (MAFLD). Here, we wanted to clarify the dynamic relationship between sarcopenia, myosteatosis, and MAFLD. METHODS: A cohort of 48 obese patients was randomised for a dietary intervention consisting of 16 g/day of inulin (prebiotic) or maltodextrin (placebo) supplementation. Before and after the intervention, we evaluated liver steatosis and stiffness with transient elastography (TE); we assessed skeletal muscle index (SMI) and skeletal muscle fat index (SMFI) (a surrogate for absolute fat content in muscle) using computed tomography (CT) and bioelectrical impedance analysis (BIA). RESULTS: At baseline, sarcopenia was uncommon in patients with MAFLD (4/48, 8.3%). SMFI was higher in patients with high liver stiffness than in those with low liver stiffness (640.6 ± 114.3 cm2/ Hounsfield unit [HU] vs. 507.9 ± 103.0 cm2/HU, p = 0.001). In multivariate analysis, SMFI was robustly associated with liver stiffness even when adjusted for multiple confounders (binary logistic regression, p <0.05). After intervention, patients with inulin supplementation lost weight, but this was not associated with a decrease in liver stiffness. Remarkably, upon intervention (being inulin or maltodextrin), patients who lowered their SMFI, but not those who increased SMI, had a 12.7% decrease in liver stiffness (before = 6.36 ± 2.15 vs. after = 5.55 ± 1.97 kPa, p = 0.04). CONCLUSIONS: Myosteatosis, but not sarcopenia, is strongly and independently associated with liver stiffness in obese patients with MAFLD. After intervention, patients in which the degree of myosteatosis decreased reduced their liver stiffness, irrespective of body weight loss or prebiotic treatment. The potential contribution of myosteatosis to liver disease progression should be investigated. CLINICAL TRIALS REGISTRATION NUMBER: NCT03852069. LAY SUMMARY: The fat content in skeletal muscles (or myosteatosis) is strongly associated with liver stiffness in obese patients with MAFLD. After a dietary intervention, patients in which the degree of myosteatosis decreased also reduced their liver stiffness. The potential contribution of myosteatosis to liver disease progression should be investigated.

5.
Eur J Radiol Open ; 7: 100290, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33335951

RESUMO

OBJECTIVES: CT is an essential diagnostic tool in health care. However, CT delivers relatively high levels of radiation which has been associated with an increased risk of childhood cancer. To address this, we evaluated patterns and time trends of CT use among children in Finland during the period in which changes in pediatric CT imaging practices were reported in several countries. METHODS: Data on CTs performed on children younger than 15 years were obtained from Finland's largest eight hospitals. CT data included the period 1996-2010 with an estimated coverage of more than 80 % of pediatric CT imaging in Finland. Joinpoint regression was used for trends analysis. CT radiation doses were estimated based on a Finnish dosimetry survey. RESULTS: A total of 48,807 pediatric CTs were performed in 1996-2010. More boys (55.5 %) were scanned than girls (42.8 %). CT numbers increased up to 2002, then decreased significantly (-6.9 % per year, 95 % CI: -10.4 to -3.2) towards 2005 and to a lesser extent thereafter, particularly among younger children. All CT types decreased in recent years, except for chest, spine, and extremities. The frequency of head CTs related to the diagnoses of intracranial injury, migraine and headache decreased towards the end of the study period. The estimated annual average effective dose from the three most common CT examinations was 0.004 mSv per child in the population. CONCLUSIONS: The frequency of pediatric CTs in Finland started to decrease after 2002. Apart from chest and orthopedic CTs, the utilization of pediatric CT imaging declined in recent years, most likely explained by improved awareness of medical radiation risks and reliance on alternative modalities such as MRI and ultrasound.

6.
Eur J Radiol Open ; 7: 100255, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32944593

RESUMO

PURPOSE: Onyx® embolization causes severe artifacts on subsequent CT-examinations, thereby seriously limiting the diagnostic quality.The purpose of this work was to compare the diagnostic quality of the tailored metal artifact reducing algorithms iMAR to standard reconstructions of CTA in patients treated with Onyx® embolization. METHOD: Twelve consecutive patients examined with Dual Energy CTA after Onyx® embolization were included. One standard image dataset without iMAR, and eight image datasets with different iMAR algorithms were reconstructed. Mean attenuation and noise were measured in the aorta or iliac arteries close to the Onyx® glue-cast and compared to the reference level in the diaphragmatic aorta. Mean attenuation and noise were also measured in the psoas muscle close to the Onyx®-glue and compared to the reference level in the psoas muscle at the level of the diaphragm.Subjective image quality and severity of artifacts was assessed by two experienced interventional radiologists blinded to reconstruction details. RESULTS: All iMAR reconstructions had less distortion of the attenuation than the standard reconstructions and were also rated significantly better than the standard reconstructions by both interventional radiologists. CONCLUSION: The iMAR algorithms can significantly reduce metal artifacts and improve the diagnostic quality in CTA in patients treated with Onyx® embolization, in many cases restoring non-diagnostic examinations to acceptable diagnostic quality.

7.
Eur J Radiol Open ; 7: 100282, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33145375

RESUMO

OBJECTIVES: The objectives of this study were to: 1) evaluate patient radiation exposure in CT and 2) establish CT Diagnostic Reference Levels (DRL)s based on clinical indication (CI) in Qatar. MATERIALS AND METHODS: Patient data for 13 CIs were collected using specially designed collection forms from the dose management software (DMS) of Hamad Medical Corporation (HMC), the main Qatar healthcare provider. The methodology described in the International Commission on Radiological Protection (ICRP) Report 135 was followed to establish national clinical DRLs in terms of Volumetric Computed Tomography Dose Index (CTDIvol) and total Dose Length Product (DLPt). Effective dose (Ef) was estimated by DMS using DLPt and appropriate conversion factors and was analyzed for comparison purposes. RESULTS: Data were retrospectively collected for 896 adult patients undergoing CT examinations in 4 hospitals and 7 CT scanners. CT for Diffuse infiltrative lung disease imparted the lowest radiation in terms of CTDIvol (5 mGy), DLPt (181 mGy.cm) and Ef (3.6 mSv). Total body CT for severe trauma imparted the highest DLPt (3137 mGy.cm) and Ef (38.6 mSv) of all CIs with a CTDIvol of 15 mGy. Rounded Third quartile CTDIvol and DLPt values were defined as the Qatar CT clinical DRLs. Comparison was limited due to sparse international literature. When this was possible data were lower or comparable with other studies. CONCLUSIONS: This is the first study reporting national clinical DRLs in Asia and second one internationally after UK. For accurate comparison between studies, systemized CI nomenclature must be followed by researchers.

8.
Eur J Radiol Open ; 7: 100253, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32964073

RESUMO

OBJECTIVES: In this phantom- and cadaver study we investigated the differences of coronary artery calcium (CAC) volume on ultra-high-resolution computed tomography (U-HRCT) scans and conventional CT. METHODS: We scanned a coronary calcium phantom and the coronary arteries of five cadavers using U-HRCT in normal- and super-high resolution (NR, SHR) mode. The NR mode was similar to conventional CT; 896 detector channels, a matrix size of 512, and a slice thickness of 0.5 mm were applied. In SHR mode, we used 1792 detector channels, a matrix size of 1024, and a slice thickness of 0.25 mm. The CAC volume on NR- and SHR images were recorded. Differences in the physical- and the calculated CAC volume were defined as the error value and compared between NR- and SHR images of the phantom. Differences between the CAC volume on NR- and SHR scans of the cadavers were also recorded. RESULTS: The mean error value was lower on SHR- than NR images of the phantom (14.0 %, SD 11.1 vs 20.1 %, SD 15.2, p = 0.01). The mean CAC volume was significantly higher on SHR- than NR images of the cadavers (153.4 mm3, SD 161.0 vs 144.7 mm3, SD 164.8, p < 0.01). CONCLUSIONS: As small calcifications were more clearly visualized on U-HRCT images in SHR mode than on conventional (NR) CT scans, SHR imaging may facilitate the accurate quantification of the CAC.

9.
Eur J Radiol Open ; 7: 100289, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33318968

RESUMO

OBJECTIVE: To determine the phase that facilitates flap observation of the ascending aorta in Stanford type A acute aortic dissection with perfused false lumen. METHODS: We reconstructed retrospective Electrocardiogram-gated Computed Tomography Angiography images of the ascending aorta of all 20 patients to 20 phases of curved-multiplanar reconstruction in 5% increment. One radiologist created and randomized 10 cross-sectional images of each phase for every patient and two radiologists scored these images on a 5-point scale depending on the degree of flap stoppage. We calculated the average score for each phase of each case and compared them among the three groups. RESULTS: Image scores were significantly better in the 65 %-100 % R-R interval group than those in the 5%-30 % (p < 2e-16) and 35 %-60 % R-R interval groups(p = 7.2e-10). Similar scores were observed in the Heart Rate > 70 group (p = 0.00039, 2.2e-14). Moreover a similar tendency was observed in the arrhythmia group (p = 0.0035, 0.294). No difference was found in the degree of flap stoppage in the 65 %-100 % R-R interval group between the Heart Rate > 70 and Heart Rate ≤ 70 groups (p = 0.466) and between the arrhythmia and non-arrhythmia groups (p = 0.1240). CONCLUSION: In observing the ascending aorta, We obtained a good image at 65 %-100 % R-R interval and similar tendency was observed in the patients with arrhythmia.

10.
Eur J Radiol Open ; 7: 100234, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32420413

RESUMO

PURPOSE: To compare CT pulmonary angiographies (CTPAs) as well as phantom scans obtained at 100 kVp with a conventional CT (C-CT) to virtual monochromatic images (VMI) obtained with a spectral detector CT (SD-CT) at equivalent dose levels as well as to compare the radiation exposure of both systems. MATERIAL AND METHODS: In total, 2110 patients with suspected pulmonary embolism (PE) were examined with both systems. For each system (C-CT and SD-CT), imaging data of 30 patients with the same mean CT dose index (4.85 mGy) was used for the reader study. C-CT was performed with 100 kVp and SD-CT was performed with 120 kVp; for SD-CT, virtual monochromatic images (VMI) with 40, 60 and 70 keV were calculated. All datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence and diagnostic performance (sensitivity, specificity). Contrast-to-noise ratio (CNR) for different iodine concentrations was evaluated in a phantom study. RESULTS: CNR was significantly higher with VMI at 40 keV compared to all other datasets. Subjective image quality as well as sensitivity and specificity showed the highest values with VMI at 60 keV and 70 keV. Hereby, a significant difference to 100 kVp (C-CT) was found for image quality. The highest sensitivity was found using VMI at 60 keV with a sensitivity of more than 97 % for all localizations of PE. For diagnostic confidence and subjective contrast, highest values were found with VMI at 40 keV. CONCLUSION: Higher levels of diagnostic performance and image quality were achieved for CPTAs with SD-CT compared to C-CT given similar dose levels. In the clinical setting SD-CT may be the modality of choice as additional spectral information can be obtained.

11.
J Saudi Heart Assoc ; 27(4): 256-63, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26557743

RESUMO

INTRODUCTION: Radiation exposure is one of the major limitations of computed tomographic coronary angiography (CTA). The purpose of this study was to compare the objective and subjective image quality and radiation dose using prospective ECG gating (PGA) versus ECG-controlled tube current modulation (ECTCM) scanning techniques. METHODS: A prospective, single-center study was performed at Prince Sultan Cardiac Centre, Qassim, Saudi Arabia. A total of 104 patients with low-to- intermediate probability of coronary artery disease (CAD) underwent CTA with either PGA or ECTCM acquisition. PGA was performed during the study period and compared with the last 50 CTAs previously done using ECTCM. A 4-point scale was used to assess the image quality subjectively. Objective image quality was assessed using image signal, noise, and signal-to-noise ratio (SNR). RESULTS: Patient's Baseline characteristics were not different between the two scanning protocols. The 4-point score of subjective image quality showed no significant differences between the PGA and ECTCM scans (2.9 ± 0.7, 2.96 ± 0.7, respectively; p = 0.87). The objective image quality showed significantly higher noise and lower SNR with PGA compared with ECTCM (31 ± 9, 27 ± 9, respectively; p < 0.001 for noise) and (15 ± 5, 17 ± 7, respectively; p < 0.001 for SNR), with no statistical difference in the image signal (434 ± 123, 425 ± 103 HU, respectively, p = 0.7). Radiation exposure was significantly lower with PGA than with ECTCM. The dose-length product (DLP) for PGA was 334 ± 130 mGy, compared with 822 ± 286 mGy for the ECTCM. This corresponds to a 59% reduction in radiation exposure (p < 0.0001). CONCLUSIONS: Although prospective ECG-triggered axial scanning increased image noise, it maintained subjective image quality and was associated with a 59% reduction in radiation exposure when compared with ECTCM.