Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 844
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Diabetol ; 23(1): 52, 2024 02 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310281

RESUMO

BACKGROUND: The outcomes of percutaneous coronary intervention (PCI) in diabetic patients are still suboptimal, and it is unclear if diabetic patients might derive a benefit from the use of drug-coated balloons. AIMS: To evaluate the impact of diabetes mellitus on the outcomes of patients undergoing PCI with sirolimus-coated balloon (SCB) MagicTouch (Concept Medical, India). METHODS: We conducted a subgroup analysis of the prospective, multicenter, investigator-initiated EASTBOURNE registry, evaluating the performance of MagicTouch SCB in patients with and without diabetes. The study primary endpoint was target lesion revascularization (TLR) at 12-month follow-up. Secondary clinical endpoints were major adverse clinical events (MACE), death, myocardial infarction (MI), and BARC 2-5 bleedings. RESULTS: Among 2,083 enrolled patients, a total of 864 suffered from diabetes (41.5%). Patients with diabetes had a numerically higher occurrence of TLR (6.5% vs. 4.7% HR 1.38, 95%CI 0.91-2.08), all-cause death (3.8% vs. 2.6%, HR 1.81, 95%CI 0.95-3.46), and MACE (12.2% vs. 8.9%; HR 1.26 95%CI 0.92-1.74). The incidence of spontaneous MI was significantly higher among diabetic patients (3.4% vs. 1.5%, HR 2.15 95%CI 1.09-4.25); bleeding events did not significantly differ. The overall incidence of TLR was higher among in-stent restenosis (ISR) as compared to de-novo coronary lesions, irrespectively from diabetes status. CONCLUSIONS: In the EASTBOURNE DIABETES registry, diabetic patients treated with the MagicTouch SCB did not have a significant increase in TLR when compared to non-diabetic patients; moreover, diabetic status did not affect the study device performance in terms of TLR, in both de-novo lesions and ISR.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/induzido quimicamente , Sistema de Registros , Reestenose Coronária/epidemiologia , Reestenose Coronária/etiologia
2.
Catheter Cardiovasc Interv ; 103(3): 404-416, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38214114

RESUMO

BACKGROUND: Some clinical trials have verified the efficacy and safety of paclitaxel drug-coated balloon (DCB) for small vessel coronary artery disease. However, nonsmall vessel and calcified lesions received less attention. AIMS: This study aimed to investigate the efficacy of DCB treatment for various types of coronary artery lesions, including not only small vessel disease but also nonsmall vessel disease and calcified lesions. In this real-world clinical practice study, in-stent restenosis was excluded. METHODS: This study consecutively included 934 patients with 1751 nonstented lesions who received DCB at a cardiovascular center in Kyoto Katsura Hospital in Japan between 2009 and 2012 and 2014 to 2019. This study enrolled and retrospectively analyzed all of the patients. Eligible patients routinely underwent follow-up angiography at 6-8 months after percutaneous coronary intervention. The primary endpoint includes target lesion revascularization (TLR) during follow-up. Further, this study calculated the predictor of TLR using multivariate analysis. RESULTS: This study included the lesions involving 46.4% of type B2/C, 26.9% with severe calcification, and 6.0% with DCB restenosis. Mean DCB diameter and length were 2.75 ± 0.51 mm and 24.2 ± 9.6 mm, respectively. The median follow-up duration was 18 months. Follow-up angiography revealed a TLR rate of 9% and a restenosis rate of 9%. This study identified hemodialysis and current smoking as independent TLR predictors. CONCLUSION: In routine clinical practice, the effectiveness of DCB was observed consistently across various types of coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Estudos Retrospectivos , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Paclitaxel/efeitos adversos , Constrição Patológica , Materiais Revestidos Biocompatíveis , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Angiografia Coronária
3.
Artigo em Inglês | MEDLINE | ID: mdl-39350479

RESUMO

BACKGROUND: Despite the widespread use of drug-coated balloons (DCBs) for femoropopliteal (FP) lesions, there is still no consensus on treatment strategies for DCB restenosis. This study aimed to determine the risk factors for recurrent restenosis after repeat DCB therapy for DCB restenosis in FP lesions. METHODS: This multicenter retrospective study assessed 1176 consecutive limbs in 860 patients who successfully received initial DCB therapy for FP lesions at four cardiovascular centers between May 2018 and December 2022. Among these patients, 118 consecutive limbs of 104 patients treated via repeat DCB for primary DCB restenosis were enrolled. RESULTS: The Kaplan-Meier estimate of freedom from recurrent restenosis was 74.6% at 1 year. Cox proportional hazard multivariate analysis revealed that recurrent restenosis was independently associated with the time from initial DCB to primary restenosis (hazard ratio [HR], 0.85; 95% confidence interval [CI], 0.79-0.92; p < 0.001), history of ≥2 endovascular therapies (EVTs) (HR, 3.11; 95%CI, 1.36-7.12; p = 0.007), and PACSS grade 3 or 4 (HR, 2.76; 95%CI, 1.15-6.63; p = 0.023). Furthermore, receiver operating characteristic curve analysis showed that the cutoff value of the time from initial DCB to primary restenosis to prevent recurrent restenosis was 12.6 months, with an area under the curve of 0.841 (p < 0.001). CONCLUSION: Repeat DCB therapy for DCB restenosis might be an acceptable strategy, particularly for restenosis that occurred more than 12.6 months after initial DCB, given the rate of freedom from recurrent restenosis.

4.
Catheter Cardiovasc Interv ; 103(1): 97-105, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37975201

RESUMO

BACKGROUND: Whether drug-coated balloon (DCB) angioplasty would be effective in spiral dissection (SD) lesions with no flow impairment has been thoroughly investigated. AIMS: The present study sought to assess the clinical outcomes of non-flow-limiting SD after DCB angioplasty for de novo femoropopliteal lesions in patients with symptomatic lower extremity artery disease. METHOD: This single-center retrospective study enrolled 497 patients with non-flow-limiting SD (n = 92) or non-SD (n = 405) without bailout stenting. The primary endpoint was 1-year primary patency, with the secondary endpoints including freedom from target lesion revascularization (TLR), major adverse limb event (MALE), all-cause death, and 30-day restenosis. RESULTS: The 1-year primary patency and freedom from TLR were significantly lower in the SD group than in the non-SD group (69.8% vs. 83.3%, p = 0.004; 78.7% vs. 93.0%, p = 0.007, respectively). The SD group had a higher incidence of MALE and 30-day restenosis than the non-SD group (24.6% vs. 11.9%, p = 0.001; 4.3% vs. 0.5%, p = 0.002, respectively). All-cause death was comparable. One-year restenosis after SD was associated with chronic limb-threatening ischemia (CLTI) (hazard ratio, 3.36 [95% confidence interval, 1.21-9.36]; p = 0.020), TASC Ⅱ D (hazard ratio, 3.97 [95% confidence interval, 1.02-15.52]; p = 0.047), and residual stenosis ≥50% (hazard ratio, 4.92 [95% confidence interval, 1.01-23.94]; p = 0.048). The incidence of restenosis after SD increased with the number of these risk factors. CONCLUSIONS: Despite normal antegrade flow, the 1-year primary patency rate after DCB angioplasty for de novo femoropopliteal lesions was significantly lower in lesions with SD than those without SD. CLTI, TASC II D, and residual stenosis ≥50% were risk factors associated with 1-year restenosis after DCB angioplasty for non-flow-limiting SD lesions.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Humanos , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/diagnóstico por imagem , Constrição Patológica , Estudos Retrospectivos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Resultado do Tratamento , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Grau de Desobstrução Vascular
5.
Artigo em Inglês | MEDLINE | ID: mdl-39381995

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) with drug-coated balloons (DCB) or drug-eluting stents (DES) are well-established treatments for in-stent restenosis, however little is known about the impact of vessel size on the outcomes. The study aimed to evaluate the efficacy and safety profile of DCB versus DES in DES in-stent restenosis depending on the vessel size. METHODS: Consecutive patients with DES in-stent restenosis who underwent PCI between January 2010 and February 2018 entered the registry with a long-term follow-up. Patients who received DCB at the index procedure were compared with those who received DES in three subgroups depending on the vessel size (≤2.5 mm; 2.5-3.5 mm; >3.5 mm). Data were analyzed using propensity score matching and Kaplan-Meier estimator plots. RESULTS: Among 1,374 patients with DES in-stent restenosis, 615 were treated with DES and 759 with DCB. After propensity score matching, we analyzed 752 patients in the DES and DCB groups at a long-term follow-up. The risk of DOCE did not differ significantly between the DES and DCB groups, both in the overall population (HR 0.85; 95%CI [0.58; 1.26], log-rank p = 0.41) and when divided into small (HR 0.84; 95%CI [0.36; 1.95], log-rank p = 0.70), medium-sized (HR 0.90; 95%CI [0.49; 1.65], log-rank p = 0.73), and large-sized (HR 0.81; 95%CI [0.42; 1.53], log-rank p = 0.50) coronary arteries. The incidence of all-cause death was significantly higher in the overall DES population (HR 4.03; 95%CI [2.40; 6.79], log-rank p < 0.001) and subgroup of small (HR 5.54; 95%CI [1.80; 17.02], log-rank p = 0.003), medium-sized (HR 4.37; 95%CI [1.92; 9.94], log-rank p = 0.009) and large-sized coronary arteries (HR 3.26; 95%CI [1.35; 7.86], log-rank p = 0.02). CONCLUSIONS: DES and DCB strategies are comparable methods of treating ISR regardless of the diameter of the treated vessel in a long-term follow-up.

6.
Artigo em Inglês | MEDLINE | ID: mdl-39044661

RESUMO

BACKGROUND: Although use of sirolimus-based analogs has shown superiority over paclitaxel in drug-eluting stents, the relative efficacy of these two agents released from drug-coated balloons (DCB) is unclear. The present meta-analysis is aimed to compare outcomes after percutaneous coronary intervention (PCI) with paclitaxel-coated balloons (PCB) versus sirolimus-coated balloons (SCB) for either in-stent restenosis or native de novo lesions. METHODS: The study outcomes were 1) target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or target lesion revascularization, and 2) follow-up angiographic parameters including late lumen loss (LLL), diameter stenosis, and minimal lumen diameter (MLD). Pooled odds ratios (OR) and weighted mean differences (WMD) with 95% confidence intervals (CI) were calculated by using random-effects models. RESULTS: A search of PubMed, EMBASE, and Cochrane Library from their inception to January 2024 identified five randomized clinical trials and three observational studies with a total of 1861 patients (889 in PCB and 972 in SCB groups). During 9-12 months of follow-up, there was no significant difference in TLF (OR 1.01, 95% CI 0.75-1.35) between the two groups. On follow-up angiography at 6-9 months, MLD (WMD 0.10, 95% CI 0.02-0.17) was larger in PCB but there was no statistically significant difference in LLL (WMD -0.11, 95% CI -0.23-0.02) and diameter stenosis (WMD -3.33, 95% CI -8.11-1.45). CONCLUSIONS: Among patients undergoing DCB-only PCI, the risk of TLF was similar during 9-12 months of follow-up after PCB and SCB treatment. However, the MLD was larger favoring PCB over SCB on follow-up angiography.

7.
Artigo em Inglês | MEDLINE | ID: mdl-39290129

RESUMO

BACKGROUND: We previously showed non-inferiority of a low-dose paclitaxel-coated balloon (PCB) with citrate excipient (Agent PCB) as compared to normal-dose iopromide excipient (SeQuent Please PCB) in terms of angiographic and clinical endpoints at 12 months. The long-term clinical efficacy and safety of Agent PCB is not defined. METHODS: 262 patients (323 DES-ISR lesions) were enrolled in this study and treated with either Agent PCB (125 patients, 151 lesions) in the ISAR-DESIRE 3a trial or with SeQuent Please PCB (137 patients, 172 lesions) in the setting of the randomized ISAR-DESIRE 3 trial with similar in- and exclusion criteria serving as historical control arm. The follow-up period was extended to 7 years. The efficacy and safety endpoints of this analysis were target-lesion revascularization (TLR), death, myocardial infarction (MI) and target lesion thrombosis (TLT) at 7 years. RESULTS: At 7 years, 206 patients (78.6%) were alive. The risks of TLR (hazard ratio [HR]: 1.29, 95% confidence interval [CI]: 0.87-1.90; p = 0.205), death (HR: 1.38, 95% CI: 0.82-2.35; p = 0.227), MI (HR: 1.10, 95% CI: 0.39-3.15; p = 0.852) and TLT (HR: 2.18, 95% CI: 0.20-24.10; p = 0.523) were comparable between Agent PCB and SeQuent PCB. Multivariate analysis showed comparable risks of TLR, death and MI between both PCB devices. CONCLUSIONS: In patients treated for DES-ISR by angioplasty with Agent PCB and SeQuent Please PCB, there was no statistically significant difference in TLR at 7 years. Randomized trials with standardized lesion preparation and long-term follow-up are warranted to further evaluate comparative efficacy of both devices. (ClinicalTrials. gov Identifier: NCT02367495).

8.
Catheter Cardiovasc Interv ; 103(4): 532-538, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38415895

RESUMO

BACKGROUND: Studies evaluating the safety and efficacy of drug coating balloons (DCB) for the treatment of lesions in large coronary vessel are limited. AIMS: Our study aimed to evaluate the performance of a sirolimus DCB in large coronary arteries. METHODS: We analyzed all the procedures included in the EASTBOURNE Registry (NCT03085823) enrolling patients with a clinical indication to percutaneous coronary intervention performed by a sirolimus DCB according to investigator judgment. In the present analysis, a cut-off of 2.75 mm was used to define large coronary arteries. Primary endpoint of the study was clinically driven target lesion revascularization (TLR) at 24 months whereas secondary endpoint included procedural success, myocardial infarction (MI), cardiac death and total mortality. RESULTS: Among the 2123 patients and 2440 lesions enrolled in the EASTBOURNE study between 2016 and 2020, 757 patients/810 lesions fulfilled the criteria for the present analysis. Mean reference vessel diameter was 3.2 ± 0.3 mm with mean lesion length of 22 ± 7 mm. Procedural success was high (96%) and at 2-year follow up the device showed a good efficacy with a TLR rate of 9%. There were 34 deaths (4.5%), 30 MIs (4%) and 8 BARC type 3-5 bleedings (1.1%). In-stent restenosis (629 lesions) and de novo lesions (181) were associated with 11% and 4% rates of TLR at 2 years, respectively (p = 0.003). CONCLUSIONS: Clinical performance of a sirolimus DCB in large coronary artery vessels shows promising signals at 2-year follow up, both in de novo and in-stent restenosis lesions.


Assuntos
Doença da Artéria Coronariana , Reestenose Coronária , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Sirolimo/efeitos adversos , Resultado do Tratamento , Angiografia Coronária , Materiais Revestidos Biocompatíveis
9.
J Endovasc Ther ; : 15266028231223086, 2024 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-38193398

RESUMO

PURPOSE: Drug-coated balloon (DCB) has been established as first-line therapy in femoropopliteal (FP) intervention, and successful vessel preparation (VP) is considered a key element. However, the clinical impact of successful VP remains unknown. This retrospective study examined the clinical impact of successful VP in DCB FP intervention. METHODS: In total, 268 patients (308 limbs) who underwent successful FP intervention using DCB without atherectomy devices for symptomatic lower extremity artery disease between March 2018 and December 2019 were included in this study (high-dose DCB: 69.8%; low-dose DCB: 30.2%). Successful VP was defined as <50% residual stenosis and

10.
J Endovasc Ther ; : 15266028241231036, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38357875

RESUMO

OBJECTIVE: The purpose of this study is to compare the initial outcomes of using the Chocolate balloon pre-dilatation (CLP) and sequential enlarging angioplasty pre-dilatation (sequential balloon pre-dilation [SP]) techniques versus the conventional balloon pre-dilatation (CP) method prior to drug-coated balloon (DCB) treatment for femoropopliteal (FP) lesions. METHODS: This was a retrospective analysis of prospectively collected data from the CIVILIAN (Clinical InVestigation of different lesIon preparation modaLIty followed by DCB in femoropopliteal Artery occlusioN disease) registry. Between March 2021 and November 2022, 3 pre-dilation techniques used prior to the DCB angioplasty were included. The study endpoint included intraoperative finial severe dissection after provisional stent placement, bailout stenting rate, the diameter of the largest pre-dilation balloon and DCB, as well as major adverse events (MAEs), including death, major limb amputation, or target vessel revascularization at 6 months. RESULTS: During the study period, 435 limbs (429 patients) were pre-dilated before DCB treatment in FP lesions, 166 limbs were pre-dilated with Chocolate balloons, 93 limbs with sequential enlarging balloon pre-dilation technique, and 176 limbs with CP. The largest pre-dilation balloon was significantly larger in CLP and SP groups than that in the CP group (CLP 4.74±0.52 mm vs CP 4.36±0.64 mm, p<0.001; SP 4.82±0.69 mm vs CP 4.36±0.63 mm, p<0.001). A consistent result was shown in DCB diameter (CLP 4.86±0.44 mm vs CP 4.71±0.51 mm, p=0.003; SP 4.90±0.58 mm vs CP 4.71±0.51 mm, p=0.006). The bailout stenting rate was significantly lower in the CLP group than that in the CP group (18.1% vs 30.1%, p=0.011). The rates of MAEs at 6 months in the CLP and SP groups were comparable to those in the CP group (7.2% and 8.6% vs 6.3%, p>0.05). The risk for intraoperative bailout stenting rate was related to TASC D classification (3.59, 95% CI: 1.83-7.05, p<0.001), chronic total occlusion (CTO) lesion (1.82, 95% CI: 1.07-3.10, p=0.028), as well as pre-dilated with the conventional balloon (1.64, 95% CI: 1.00-2.69, p=0.048). CONCLUSIONS: By utilizing chocolate balloon and sequential enlarging angioplasty, it becomes possible to use larger pre-dilation balloons and DCBs. In addition, the use of the chocolate balloon can significantly reduce the need for bailout stenting when compared with conventional balloons. CLINICAL IMPACT: The utilization of a chocolate balloon and sequential enlarging angioplasty has emerged as a promising technique for angioplasty procedures. This approach allows for the use of larger pre-dilation balloons and drug-coated balloons. The use of the chocolate balloon can significantly reduce the need for bail-out stenting when compared to conventional balloons. Further research is required to determine the impact of vessel preparation techniques on the primary patency.

11.
J Endovasc Ther ; : 15266028241271725, 2024 Aug 26.
Artigo em Inglês | MEDLINE | ID: mdl-39183676

RESUMO

BACKGROUND: Previous reports have shown comparable outcomes between drug-eluting stents (DESs) and drug-coated balloons (DCBs) for treating femoropopliteal artery (FPA) lesions; however, DCB outcomes include approximately 10% to 50% bailout stents. Therefore, comparing DESs and DCBs is not simple. The aim of this study was to compare the clinical outcomes of DESs and DCBs in patients with symptomatic FPA disease. MATERIALS AND METHODS: Using the registries of 7 institutions, we retrospectively reviewed the records of 1356 patients who underwent endovascular therapy for FPA with DESs (n=333; Eluvia, 74.0%; Zilver PTX stent, 26.0%) or DCBs without bailout stents (n=1023; IN.PACT, 67.6%; Lutonix, 32.4%). The primary outcome was the 1-year primary patency comparison between DESs and DCBs, using propensity score matching. The severity of the dissection pattern after predilatation (none or grades A-C) was included as an explanatory variable for matching. Patients with grade D dissections were excluded from the main analysis and assessed independently. RESULTS: After matching, the 1-year primary patency between DESs and DCBs was similar (88.8% vs 85.2%, p=0.31). By contrast, perioperative complications were frequent with DES, compared with DCB (5.1% vs 2.2%, p=0.005), and the intravascular ultrasound-evaluated minimum luminal area was significantly larger with DES than with DCB (19 mm2 vs 14 mm2, p<0.001). In the supplemental analysis of lesions with grade D dissection, the 1-year primary patency was significantly higher with DES than with DCB (86.1% vs 55.1%, p=0.014). CONCLUSION: In FPA lesions without severe dissection (ie, no dissection or grade A-C dissection), DESs and DCBs showed comparable 1-year primary patency in matched populations. However, DCBs did not perform well with severe dissection (ie, grade D or more). CLINICAL IMPACT: The results of this study clearly define the appropriate boundaries for the "leaving nothing behind" strategy. Clinicians can now more clearly differentiate between the use of DES and DCB, based on the results of lesion preparation. Further prospective investigations with well-designed trials and larger populations are necessary to confirm these findings.

12.
J Endovasc Ther ; : 15266028241267759, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-39148336

RESUMO

PURPOSE: Clinical trials have demonstrated that high-dose drug-coated balloon (HD-DCB) and polymer-based drug-eluting stent (PB-DES) treatments for femoropopliteal (FP) artery disease have favorable outcomes. However, which one would be better remained unrevealed. METHODS: This study used the databases of 2 large-scale multicenter prospective drug-coated balloon (DCB) and drug-eluting stent (DES) registries. The study included 2470 patients with symptomatic FP lesion treated with IN.PACT Admiral DCB or Eluvia DES at 69 centers. A propensity-score-based paired analysis was conducted. Primary endpoint was 1-year restenosis rate. Secondary endpoints were 1-year reocclusion rate, target lesion revascularization (TLR), acute thrombosis, bypass conversion, major amputation, major adverse limb event (MALE), and all-cause death. RESULTS: A total of 1535 patients were treated with HD-DCB, and 935 patients were treated with PB-DES. The propensity-score matching extracted 678 pairs, with no remarkable intergroup difference in baseline characteristics. The 1-year restenosis rate was significantly lower in the PB-DES group than in the HD-DCB group (16.0% vs 22.0%, p=0.016). The other endpoints (reocclusion rate, TLR, acute thrombosis, bypass conversion, major amputation, MALE, and all-cause death) did not differ between the groups. No baseline characteristics had any significant interaction effect on the association of HD-DCB vs PB-DES with restenosis risk (all p>0.05). CONCLUSIONS: This study demonstrated that the 1-year TLR, reocclusion rate, and other endpoints did not differ between the PB-DES group and the HD-DCB group despite the lower restenosis in the PB-DES group. CLINICAL IMPACT: One-year restenosis rate was significantly lower in the polymer-based DES group than in the high-dose DCB group for foemoropopliteal disease. However, there is no difference in the other endpoints between two groups.

13.
J Endovasc Ther ; : 15266028241248333, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38659343

RESUMO

BACKGROUND: Despite improved patency with newer-generation nitinol stents, one-half of patients will require secondary interventions for in-stent restenosis (ISR). The best treatment strategy remains unclear. This study aimed to compare drug-coated balloons (DCBs) used alone or in association with excimer laser atherectomy (ELA) to simple percutaneous transluminal angioplasty (PTA) in the treatment of femoropopliteal-ISR. METHODS: The INTACT trial is a multicenter, prospective, triple-arm randomized trial conducted across 14 centers from December 2015 to November 2019. Patients Rutherford Class 2-5 with ISR≥70% were followed-up for 18 months. The primary efficacy endpoint was recurrent ISR>70% by duplex ultrasound analysis. The primary safety endpoint was major adverse events (MAEs) defined as death, major amputation, or target lesion revascularization (TLR). RESULTS: Around 134 subjects were randomized to PTA alone (n=41), PTA+DCB (n=43) or PTA+ELA+DCB (n=50). Procedural success was similar (p=.74), as was clinical success (p=.17). The number of recurrent ISR>70% decreased after PTA+ELA+DCB (30.0%; p=.04) and PTA+DCB (30.2%; p=.05) compared to PTA alone (51.2%). Primary patency was higher after PTA+ELA+DCB (log-rank p=.04) and PTA+DCB (log-rank p=.02) compared to PTA alone at 12 months (78.7% and 70.4% vs 61.5%) and 18 months (61.6% and 67.7% vs 37.3%). Freedom from MAEs was lower after PTA+DCB (27.9%) compared to PTA alone (53.7%; p=.02) but did not differ with PTA+ELA+DCB (40.0%). It was primarily driven by TLR; 2 major amputations occurred after PTA+ELA+DCB (4.0%; p=.18). CONCLUSION: This independent study demonstrated a decrease in recurrent ISR>70% and increase in primary patency up to 18 months after PTA+ELA+DCB and PTA+DCB compared to PTA alone in the treatment of FP-ISR. It did not show an increase in MAEs but could have lacked power. CLINICAL IMPACT: This multicenter, prospective, triple-arm randomized, controlled trial focuses on the results of adjunctive therapies, such as excimer laser atherectomy (ELA) and/or drug-coated balloons (DCBs) in the treatment of in-stent restenosis (ISR) in femoropopliteal lesions in 134 patients. It has the originality of being an independent study funded by a grant from the French Ministry of Health. This study confirms a significant decrease in recurrent ISR >70% and increase in primary patency up to 18 months after the use of ELA+DCB and DCBs compared to simple percutaneous transluminal angioplasty in the treatment of femoropopliteal ISR without an increase in major adverse events.

14.
J Endovasc Ther ; : 15266028241241967, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38577781

RESUMO

CLINICAL IMPACT: This retrospective observational registry trial combines national registries for vascular surgical procedures and diabetes mellitus to clarify results of drug eluting technology in treating diabetic subjects with intermittent claudication or chronic limb threatening ischemia compared to treatment of non-diabetic subjects. As earlier proposed and showed in this trial, there may be an implication for a beneficial treatment efficacy with drug eluting therapy in the diabetic population with PAD compared to the non-diabetic population. A finding worth further exploration.

15.
J Endovasc Ther ; : 15266028241280685, 2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39305087

RESUMO

PURPOSE: Vessel recoil is a common phenomenon occurring in the tibial vessels following balloon angioplasty. This study examined the occurrence and short-term impact of acute vessel recoil in a subset of patients treated with retrievable scaffold therapy (RST) via the Spur Peripheral Retrievable Scaffold System (Spur). METHODS: Patients with tibial disease underwent angiography immediately following RST, and then 15 minutes post-treatment. Vessel recoil was defined as a ≥10% decrease in lumen diameter after 15 minutes. Recoil was further analyzed by late lumen loss method, subsegmental late lumen loss method, and smallest segment to same segment method. Patient and vessel characteristics were evaluated. Functional recoil (acute vessel spasm), defined as no significant change in minimal lumen diameter (MLD) at baseline compared with 15 minutes post-treatment, was also evaluated. RESULTS: Of the 38 patients (40 lesions; 33 men [87%]; mean [SD] age 75.3 [8.2] years; 26 (68.4%) with diabetes mellitus); recoil was noted in 42.5% of vessels. Prior to treatment, 13 lesions (32.5%) were total occlusions, the mean lesion length was 64.7±30.4 mm, and 27.5% (11/40) were moderate or severely calcified. Mean treated lesion length was 97.8±39.6 mm. For lesions evaluable by duplex ultrasound, 86.7% of vessels (26/30) were patent at 6 months. There was no significant difference in patency between lesions with recoil and lesions without recoil (81.8% vs 89.5%); there was a trend toward patency in the non-recoil group. Two lesions had functional recoil (acute vessel spasm) and were patent at 6 months. There was no statistically significant correlation of recoil to comorbidities or lesion characteristics, including calcification, for which there was also no correlation to patency. CONCLUSION: Vessel recoil was noted in 42.5% of vessels treated with RST, whereas previous published rates with balloon angioplasty demonstrated vessel recoil up to 97%, suggesting that RST may impact vessel recoil. This exploratory study did not demonstrate a correlation between vessel recoil and patency at 6 months. CLINICAL IMPACT: Retrievable scaffold therapy may replace scoring devices and cutting devices for vessel preparation before definite (drug) therapy. Retrievable scaffold therapy supplements already established vessel preparation strategies in order to follow the concept of leaving nothing behaind. A temporary retrievable scaffold for changing vessel compliance and potentially releasing antiproliferative drugs represents a new interventional concept.

16.
J Vasc Interv Radiol ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39218214

RESUMO

PURPOSE: To evaluate the effect of drug-coated balloon (DCB) with high-dose paclitaxel for the treatment of restenotic dysfunctional arteriovenous fistulas (AVFs). MATERIALS AND METHODS: In this single-arm, multicenter, prospective, observational study, 334 patients using IN.PACT AV DCB (Medtronic Inc., Plymouth, MN) for the first time in the restenotic lesion of dysfunctional AVF between April 2021 and March 2022 were registered. RESULTS: Procedural success, defined as <30% residual stenosis, was achieved in 96.7% of cases. During a median follow-up of 7.4 months, 179 target lesion reinterventions (TLRs) were observed, and the 6-month freedom from TLR was 73.2% (68.2%-78.2%). When compared with the previous plain percutaneous transluminal angioplasty, the median time to reintervention was significantly longer with DCB (9.1 [8.0-10.6] versus 3.2 [3.0-3.4] months; P<.001). Baseline characteristics that were independently associated with TLR were: months from the last intervention (adjusted hazard ratio, 0.50 [95% confidence interval, 0.40-0.62] per doubling; P<.001), partial lesion coverage by DCB (2.13 [1.10-4.12]; P=.024), and residual stenosis after DCB (2.19 [1.53-3.12] per 15% increase; P<.001) with its time interaction (0.91 [0.86-0.97] per month; P=.003). Of the 179 TLRs, 84 used DCB once again. The median time to reintervention was significantly longer for TLR using DCB (7.1 [6.2-9.7] versus 3.3 [3.1-4.0] months; P<.001). CONCLUSIONS: DCB with high-dose paclitaxel is effective at both the initial treatment in the restenotic lesion of dysfunctional AVF and during TLR after DCB use. However, partial lesion coverage by DCB and residual stenosis should be avoided.

17.
Eur J Vasc Endovasc Surg ; 67(5): 799-808, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38182107

RESUMO

OBJECTIVE: To investigate dissection severity, need for bailout stenting and limb outcomes in patients undergoing antegrade vs. retrograde revascularisation. METHODS: Consecutive patients who underwent either antegrade or retrograde revascularisation after failed antegrade recanalisation of long femoropopliteal chronic total occlusion (CTO) due to symptomatic peripheral artery disease between January 2017 and June 2022 were studied. Retrospective case control matching was used to adjust for lesion length and calcification using the peripheral artery calcification scoring system (PACSS). Procedural outcomes included severity of dissection (Type A to F dissections, numerically graded on a scale from 0 - 6 with increasing severity) after angioplasty and number and location of stents needed to be implanted during the index procedure. Additionally, clinically driven target lesion revascularisation (CD-TLR) and major (above ankle) amputation rates were assessed during follow up. RESULTS: A total of 180 patients were analysed who underwent antegrade (n = 90) or retrograde after failed antegrade (n = 90) recanalisation. The median patient age was 76.0 (interquartile range [IQR] 67.0, 82.0) years and 76 (42.2%) were female. Moreover, 78 patients (43.3%) had intermittent claudication, whereas 102 (56.7%) had chronic limb threatening ischaemia (CLTI). The mean lesion length was 30.0 (IQR 24.0, 36.0) cm with moderate to severe (3.0 [IQR 2.0, 4.0]) lesion calcification. Dissection severity after angioplasty was higher in the antegrade than retrograde after failed antegrade recanalisation group (4.0 [IQR 3.0, 4.0] vs. 3.0 [IQR 2.0, 4.0]; p < .001). Additionally, the number of stents in all segments and the rate of bailout stenting in popliteal segments was significantly higher with the antegrade strategy (2.0 [IQR 1.0, 3.0] vs. 1.0 [IQR 0, 2.0], p < .010; and 37% vs. 14%, p < .001). During a median follow up of 1.48 (IQR 0.63, 3.09) years, CD-TLR rates (p = .90) and amputation rates in patients with CLTI (p = .15) were not statistically significant. CONCLUSION: In complex femoropopliteal CTOs, retrograde after failed antegrade recanalisation, is safe for endovascular revascularisation, which in experienced hands may result in less severe dissections and lower rates of stent placement. However, considering the relatively short follow up, CD-TLR and amputation rates were not statistically different between the two approaches. [German Clinical Trials Register: DRKS00015277.].


Assuntos
Amputação Cirúrgica , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Stents , Humanos , Idoso , Feminino , Masculino , Estudos Retrospectivos , Artéria Femoral/cirurgia , Artéria Femoral/fisiopatologia , Artéria Femoral/diagnóstico por imagem , Artéria Poplítea/cirurgia , Artéria Poplítea/fisiopatologia , Artéria Poplítea/diagnóstico por imagem , Doença Arterial Periférica/cirurgia , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Amputação Cirúrgica/estatística & dados numéricos , Salvamento de Membro/métodos , Resultado do Tratamento , Falha de Tratamento , Índice de Gravidade de Doença , Grau de Desobstrução Vascular , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos
18.
Circ J ; 88(10): 1647-1655, 2024 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-39069494

RESUMO

BACKGROUND: Endovascular therapy (EVT) with devices such as drug-coated balloons (DCBs) and drug-eluting stents (DESs) for atherosclerotic disease in the femoropopliteal (FP) artery has been established. However, EVT using drug-based devices for chronic limb-threatening ischemia (CLTI) remains challenging. The optimal device for FP lesions in patients with CLTI remains unknown. This study compared the clinical efficacy of DCB and DES in patients with CLTI and FP lesions. METHODS AND RESULTS: This retrospective single-center study included 539 consecutive patients (562 lesions) treated with EVT between January 2018 and December 2022; 166 patients with CLTI and Rutherford Class 5 or 6 wounds underwent EVT with DCB or DES. Clinical outcomes were compared between 53 pairs after propensity score matching. There were no significant differences between the DCB and DES groups in the incidence of complete wound healing without death or major amputation (84.8% vs. 80.2%, respectively; P=0.99), primary patency (69.4% vs. 75.6%, respectively; P=0.65), and freedom from target lesion revascularization at 1 year (78.6% vs. 78.0%, respectively; P=0.92). Multivariate analysis showed that complete wound healing at 1 year is negatively associated with hemodialysis and Wound, Ischemia, and foot Infection Stage 4, but positively associated with Global Limb Anatomic Staging System FP Grade 3 or 4. CONCLUSIONS: No significant differences in clinical outcomes were found between DCB and DES for patients with CLTI and FP lesions.


Assuntos
Stents Farmacológicos , Artéria Femoral , Doença Arterial Periférica , Artéria Poplítea , Humanos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Artéria Femoral/cirurgia , Doença Arterial Periférica/terapia , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Isquemia Crônica Crítica de Membro/cirurgia , Materiais Revestidos Biocompatíveis , Cicatrização , Salvamento de Membro , Grau de Desobstrução Vascular , Amputação Cirúrgica , Resultado do Tratamento
19.
Vasc Med ; 29(4): 369-380, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38623630

RESUMO

BACKGROUND: Paclitaxel (PTX) is touted as an essential medicine due to its extensive use as a chemotherapeutic agent for various cancers and an antiproliferative agent for endovascular applications. Emerging studies in cardio-oncology implicate various vascular complications of chemotherapeutic agents. METHODS: We evaluated the inflammatory response induced by the systemic administration of PTX. The investigation included RNAseq analysis of primary human endothelial cells (ECs) treated with PTX to identify transcriptional changes in pro-inflammatory mediators. Additionally, we used dexamethasone (DEX), a well-known antiinflammatory compound, to assess its effectiveness in counteracting these PTX-induced changes. Further, we studied the effects of PTX on monocyte chemoattractant protein-1 (MCP-1) levels in the media of ECs. The study also extended to in vivo analysis, where a group of mice was injected with PTX and subsequently harvested at different times to assess the immediate and delayed effects of PTX on inflammatory mediators in blood and aortic ECs. RESULTS: Our RNAseq analysis revealed that PTX treatment led to significant transcriptional perturbations in pro-inflammatory mediators such as MCP-1 and CD137 within primary human ECs. These changes were effectively abrogated when DEX was administered. In vitro experiments showed a marked increase in MCP-1 levels in EC media following PTX treatment, which returned to baseline upon treatment with DEX. In vivo, we observed a threefold increase in MCP-1 levels in blood and aortic ECs 12 h post-PTX administration. Similar trends were noted for CD137 and other downstream mediators like tissue factor, vascular cell adhesion molecule 1, and E-selectin in aortic ECs. CONCLUSION: Our findings illustrate that PTX exposure induces an upregulation of atherothrombotic mediators, which can be alleviated with concurrent administration of DEX. Considering these observations, further long-term investigations should focus on understanding the systemic implications associated with PTX-based therapies and explore the clinical relevance of DEX in mitigating such risks.


Assuntos
Anti-Inflamatórios , Quimiocina CCL2 , Dexametasona , Células Endoteliais , Mediadores da Inflamação , Camundongos Endogâmicos C57BL , Paclitaxel , Paclitaxel/efeitos adversos , Paclitaxel/administração & dosagem , Humanos , Animais , Anti-Inflamatórios/farmacologia , Anti-Inflamatórios/efeitos adversos , Quimiocina CCL2/metabolismo , Quimiocina CCL2/genética , Dexametasona/efeitos adversos , Mediadores da Inflamação/metabolismo , Células Cultivadas , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Masculino , Doença Iatrogênica , Células Endoteliais da Veia Umbilical Humana/metabolismo , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , RNA-Seq , Fatores de Tempo , Regulação da Expressão Gênica/efeitos dos fármacos , Transdução de Sinais , Camundongos
20.
Artigo em Inglês | MEDLINE | ID: mdl-38805160

RESUMO

BACKGROUND: AccuFFRangio is a novel method for fast computation of fractional flow reserve (FFR) based on coronary angiography and computational fluid dynamics. The association between the AccuFFRangio and clinical outcomes after drug-coated balloon (DCB) or plain old balloon angioplasty (POBA) remains to be investigated. METHODS: This study included consecutive patients who underwent balloon angioplasty from December 2016 to October 2020. AccuFFRangio was calculated retrospectively based on the post-procedural angiography obtained immediately after angioplasty. The primary endpoint was major adverse cardiac events (MACE), defined as a composite of all-cause death, vessel-related myocardial infarction, and repeat target vessel revascularization. RESULTS: A total of 169 patients were retrospectively analyzed in this study. Post-procedural AccuFFRangio (hazard ratio [HR] per 0.1 increase 0.33, 95% confidence interval [CI] 0.22-0.48, p < 0.001) was an independent predictor for MACE at 2-year follow-up. Post-procedural AccuFFRangio ≤ 0.87 was determined as the optimal cutoff value to predict MACE with an area under the curve (AUC) of 0.872 (95% CI 0.813-0.919, p < 0.001). CONCLUSIONS: AccuFFRangio measured immediately after balloon angioplasty is a promising predictor of unfavorable clinical outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA