Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 541
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38336883

RESUMO

OBJECTIVES: To determine the clinical associations and predictive value of two thresholds of negative dual-energy CT (DECT) for MSU crystal deposition in gout patients initiating urate lowering therapy (ULT), and identify which threshold is more clinically relevant. METHODS: Patients from the CRYSTALILLE cohort with a diagnosis of gout naive to ULT with baseline DECT scans of knees and feet were selected. Two thresholds of positivity for DECT detection of MSU crystal deposition were considered (<0.01 cm3 and <0.1 cm3). Baseline characteristics and the prediction of key outcomes after ULT initiation including reaching serum urate (SU) levels <6.0 and 5.0 mg/dl and occurrence of flares at 6, 12 and 24 months, associated with both thresholds of negative DECTs were compared with those of. PATIENT: s having positive DECT scans. RESULTS: 211 patients aged 66.2 years [57; 75.8] with a symptom duration of 3 years [0; 7.8] were included. 38/211 (18%) and 90/211 (43%) had negative DECT scans for the 0.01 and 0.1 cm3 thresholds, respectively. Factors associated with negative DECT scans were younger age, shorter symptom duration, and absence of cardiovascular disease for both volume thresholds. 9/39 (23.1%), 3/26 (11.5%), and 1/18 (5.6%) of patients with <0.1 cm3 MSU crystals had flares at 6, 12 and 24 months, respectively, compared with 18/45 (40.0%), 9/36 (25.0%) and 2/18 (11.1%) patients with ≥0.1 cm3 (p> 0.05).Overall, 95 patients (68.3%) reached SU levels <6.0 mg/dl and 68 (48.9%) <5.0 mg/dl, without any difference between positive and negative DECTs, with ULT dosages which tended to be lower in patients with negative DECT. CONCLUSION: The 0.1 cm3 threshold was better correlated to clinical presentation and evolution than 0.01 cm3. Patients with gout with negative DECTs exhibit milder disease and a lower comorbidity burden. They do not exhibit particularly easy-to-treat hyperuricemia, but may have a lower risk of flares.

2.
Eur J Clin Invest ; 54(4): e14139, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38063028

RESUMO

BACKGROUND: Technological progress in the acquisition of medical images and the extraction of underlying quantitative imaging data has introduced exciting prospects for the diagnostic assessment of a wide range of conditions. This study aims to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for classifying pulmonary embolism (PE) severity and assessing the risk for early death. METHODS: Patients who underwent CT pulmonary angiogram (CTPA) between January 2015 and March 2022 were considered for inclusion in this study. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models. RESULTS: The trained machine learning classifier achieved a classification accuracy of .90 for identifying high-risk PE patients with an area under the receiver operating characteristic curve of .59. This CT-based radiomics signature showed good diagnostic accuracy for risk stratification in individuals presenting with central PE, particularly within higher risk groups. CONCLUSION: Models utilizing DECT-derived radiomics features can accurately stratify patients with pulmonary embolism into established clinical risk scores. This approach holds the potential to enhance patient management and optimize patient flow by assisting in the clinical decision-making process. It also offers the advantage of saving time and resources by leveraging existing imaging to eliminate the necessity for manual clinical scoring.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Radiômica , Reprodutibilidade dos Testes , Embolia Pulmonar/diagnóstico por imagem , Medição de Risco , Estudos Retrospectivos
3.
Eur Radiol ; 34(3): 1816-1824, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37667141

RESUMO

OBJECTIVES: To evaluate the applicability of Bosniak 2019 criteria on a monophasic portal venous phase using rapid kilovoltage-switching DECT (rsDECT). MATERIALS AND METHODS: One hundred twenty-seven renal masses assessed on rsDECT were included, classified according to Bosniak 2019 classification using MRI as the reference standard. Using the portal venous phase, virtual monochromatic images at 40, 50, and 77 keV; virtual unenhanced (VUE) images; and iodine map images were reconstructed. Changes in attenuation values between VUE and 40 keV, 50 keV, and 77 keV measurements were computed and respectively defined as ∆HU40keV, ∆HU50keV, and ∆HU77keV. The values of ∆HU40keV, ∆HU50keV, and ∆HU77keV thresholds providing the optimal diagnostic performance for the detection of internal enhancement were determined using Youden index. RESULTS: Population study included 25 solid renal masses (25/127, 20%) and 102 cystic renal masses (102/127, 80%). To differentiate solid to cystic masses, the specificity of the predefined 20 HU threshold reached 88% (95%CI: 82, 93) using ∆HU77keV and 21% (95%CI: 15, 28) using ∆HU40keV. The estimated optimal threshold of attenuation change was 19 HU on ∆HU77keV, 69 HU on ∆HU50eV, and 111 HU on ∆HU40eV. The rsDECT classification was highly similar to that of MRI for solid renal masses (23/25, 92%) and for Bosniak 1 masses (62/66, 94%). However, 2 hyperattenuating Bosniak 2 renal masses (2/26, 8%) were classified as solid renal masses on rsDECT. CONCLUSION: DECT is a promising tool for Bosniak classification particularly to differentiate solid from Bosniak I-II cyst. However, known enhancement thresholds must be adapted especially to the energy level of virtual monochromatic reconstructions. CLINICAL STATEMENT: DECT is a promising tool for Bosniak classification; however, known enhancement thresholds must be adapted according to the types of reconstructions used and especially to the energy level of virtual monochromatic reconstructions. KEY POINTS: • To differentiate solid to cystic renal masses, predefined 20 HU threshold had a poor specificity using 40 keV virtual monochromatic images. • Most of Bosniak 1 masses according to MRI were also classified as Bosniak 1 on rapid kV-switching dual-energy CT (rsDECT). • Bosniak 2 hyperattenuating renal cysts mimicked solid lesion on rsDECT.


Assuntos
Doenças Renais Císticas , Neoplasias Renais , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Humanos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Rim/patologia , Imageamento por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Meios de Contraste
4.
Eur Radiol ; 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834786

RESUMO

OBJECTIVES: We aimed to develop and validate a radiomics nomogram based on dual-energy computed tomography (DECT) images and clinical features to classify the time since stroke (TSS), which could facilitate stroke decision-making. MATERIALS AND METHODS: This retrospective three-center study consecutively included 488 stroke patients who underwent DECT between August 2016 and August 2022. The eligible patients were divided into training, test, and validation cohorts according to the center. The patients were classified into two groups based on an estimated TSS threshold of ≤ 4.5 h. Virtual images optimized the visibility of early ischemic lesions with more CT attenuation. A total of 535 radiomics features were extracted from polyenergetic, iodine concentration, virtual monoenergetic, and non-contrast images reconstructed using DECT. Demographic factors were assessed to build a clinical model. A radiomics nomogram was a tool that the Rad score and clinical factors to classify the TSS using multivariate logistic regression analysis. Predictive performance was evaluated using receiver operating characteristic (ROC) analysis, and decision curve analysis (DCA) was used to compare the clinical utility and benefits of different models. RESULTS: Twelve features were used to build the radiomics model. The nomogram incorporating both clinical and radiomics features showed favorable predictive value for TSS. In the validation cohort, the nomogram showed a higher AUC than the radiomics-only and clinical-only models (AUC: 0.936 vs 0.905 vs 0.824). DCA demonstrated the clinical utility of the radiomics nomogram model. CONCLUSIONS: The DECT-based radiomics nomogram provides a promising approach to predicting the TSS of patients. CLINICAL RELEVANCE STATEMENT: The findings support the potential clinical use of DECT-based radiomics nomograms for predicting the TSS. KEY POINTS: Accurately determining the TSS onset is crucial in deciding a treatment approach. The radiomics-clinical nomogram showed the best performance for predicting the TSS. Using the developed model to identify patients at different times since stroke can facilitate individualized management.

5.
Eur Radiol ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755438

RESUMO

OBJECTIVES: To compare the diagnostic performance and image quality of dual-energy computed tomography (DECT) with electron density (ED) image reconstruction with those of DECT with standard CT (SC) and virtual non-calcium (VNCa) image reconstructions, for diagnosing lumbar disc herniation (L-HIVD). METHODS: A total of 59 patients (354 intervertebral discs from T12/L1 to L5/S1; mean age, 60 years; 30 women and 29 men) who underwent DECT with spectral reconstruction and 3-T MRI within 2 weeks were enrolled between March 2021 and February 2022. Four radiologists independently assessed three image sets of randomized ED, SC, and VNCa images to detect L-HIVD at 8-week intervals. The coefficient of variance (CV) and the Weber contrast of the ROIs in the normal and diseased disc to cerebrospinal fluid space (NCR-normal/-diseased, respectively) were calculated to compare the image qualities of the noiseless ED and other series. RESULTS: Overall, 129 L-HIVDs were noted on MRI. In the detection of L-HIVD, ED showed a higher AUC and sensitivity than SC and VNCa; 0.871 vs 0.807 vs 833 (p = 0.002) and 81% vs 70% vs 74% (p = 0.006 for SC), respectively. CV was much lower in all measurements of ED than those for SC and VNCa (p < 0.001). Furthermore, NCR-normal and NCR-diseased were the highest in ED (ED vs SC in NCR-normal and NCR-diseased, p = 0.001 and p = 0.004, respectively; ED vs VNCa in NCR-diseased, p = 0.044). CONCLUSION: Compared to SC and VNCa images, DECT with ED reconstruction can enhance the AUC and sensitivity of L-HIVD detection with a lower CV and higher NCR. CLINICAL RELEVANCE STATEMENT: To our knowledge, this is the first study to quantify the image quality of noiseless ED images. ED imaging may be helpful for detecting L-HIVD in patients who cannot undergo MRI. KEY POINTS: ED images have diagnostic potential, but relevant quantitative analyses of image quality are limited. ED images detect disc herniation, with a better coefficient of variance and normalized contrast ratio values. ED images could detect L-HIVD when MRI is not an option.

6.
Eur Radiol ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38856781

RESUMO

OBJECTIVES: Our study comprised a single-center retrospective in vitro correlation between spectral properties, namely ρ/Z values, derived from scanning blood samples using dual-energy computed tomography (DECT) with the corresponding laboratory hemoglobin/hematocrit (Hb/Hct) levels and assessed the potential in anemia-detection. METHODS: DECT of 813 patient blood samples from 465 women and 348 men was conducted using a standardized scan protocol. Electron density relative to water (ρ or rho), effective atomic number (Zeff), and CT attenuation (Hounsfield unit) were measured. RESULTS: Positive correlation with the Hb/Hct was shown for ρ (r-values 0.37-0.49) and attenuation (r-values 0.59-0.83) while no correlation was observed for Zeff (r-values -0.04 to 0.08). Significant differences in attenuation and ρ values were detected for blood samples with and without anemia in both genders (p value < 0.001) with area under the curve ranging from 0.7 to 0.95. Depending on the respective CT parameters, various cutoff values for CT-based anemia detection could be determined. CONCLUSION: In summary, our study investigated the correlation between DECT measurements and Hb/Hct levels, emphasizing novel aspects of ρ and Zeff values. Assuming that quantitative changes in the number of hemoglobin proteins might alter the mean Zeff values, the results of our study show that there is no measurable correlation on the atomic level using DECT. We established a positive in vitro correlation between Hb/Hct values and ρ. Nevertheless, attenuation emerged as the most strongly correlated parameter with identifiable cutoff values, highlighting its preference for CT-based anemia detection. CLINICAL RELEVANCE STATEMENT: By scanning multiple blood samples with dual-energy CT scans and comparing the measurements with standard laboratory blood tests, we were able to underscore the potential of CT-based anemia detection and its advantages in clinical practice. KEY POINTS: Prior in vivo studies have found a correlation between aortic blood pool and measured hemoglobin and hematocrit. Hemoglobin and hematocrit correlated with electron density relative to water and attenuation but not Zeff. Dual-energy CT has the potential for additional clinical benefits, such as CT-based anemia detection.

7.
Curr Rheumatol Rep ; 26(8): 302-310, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38739298

RESUMO

PURPOSE OF REVIEW: To highlight novel findings in the detection of monosodium urate deposits in vessels using dual energy computed tomography, and to discuss the potential clinical implications for gout and hyperuricemia patients. RECENT FINDINGS: Gout is an independent risk factor for cardiovascular disease. However, classical risk calculators do not take into account these hazards, and parameters to identify patients at risk are lacking. Monosodium urate measured by dual energy computed tomography is a well-established technology for the detection and quantification of monosodium urate deposits in peripheral joints and tendons. Recent findings also suggest its applicability to identify vascular urate deposits. Dual energy computed tomography is a promising tool for detection of cardiovascular monosodium urate deposits in gout patients, to better delineate individuals at increased risk for cardiovascular disease.


Assuntos
Gota , Tomografia Computadorizada por Raios X , Ácido Úrico , Humanos , Ácido Úrico/análise , Tomografia Computadorizada por Raios X/métodos , Gota/diagnóstico por imagem , Hiperuricemia/diagnóstico por imagem , Doenças Cardiovasculares/diagnóstico por imagem
8.
Neuroradiology ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985319

RESUMO

PURPOSE: To develop thrombus radiomics models based on dual-energy CT (DECT) for predicting etiologic cause of stroke. METHODS: We retrospectively enrolled patients with occlusion of the middle cerebral artery who underwent computed tomography (NCCT) and DECT angiography (DECTA). 70 keV virtual monoenergetic images (simulate conventional 120kVp CTA images) and iodine overlay maps (IOM) were reconstructed for analysis. Five logistic regression radiomics models for predicting cardioembolism (CE) were built based on the features extracted from NCCT, CTA and IOM images. From these, the best one was selected to integrate with clinical information for further construction of the combined model. The performance of the different models was evaluated and compared using ROC curve analysis, clinical decision curves (DCA), calibration curves and Delong test. RESULTS: Among all the radiomic models, model NCCT+IOM performed the best, with AUC = 0.95 significantly higher than model NCCT, model CTA, model IOM and model NCCT+CTA in the training set (AUC = 0.88, 0.78, 0.90,0.87, respectively, P < 0.05), and AUC = 0.92 in the testing set, significantly higher than model CTA (AUC = 0.71, P < 0.05). Smoking and NIHSS score were independent predictors of CE (P < 0.05). The combined model performed similarly to the model NCCT+IOM, with no statistically significant difference in AUC either in the training or test sets. (0.96 vs. 0.95; 0.94 vs. 0.92, both P > 0.05). CONCLUSION: Radiomics models constructed based on NCCT and IOM images can effectively determine the source of thrombus in stroke without relying on clinical information.

9.
Int J Med Sci ; 21(9): 1640-1648, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39006836

RESUMO

Objective: Our study aims to evaluate the value of 256-slice dual-energy computed tomography (DECT) in supporting prostatic artery embolization (PAE) under digital subtraction angiography (DSA) for benign prostatic hyperplasia (BPH). Methods: The study was conducted on 88 patients who underwent PAE to treat BPH from January 2022 to November 2023. Of these, 38 patients who had PAE without DECT were placed in group 1, while the other 50 patients with pre-interventional DECT were assigned to group 2. The results of DECT imaging of the prostate artery (PA) were compared with the results of DSA imaging. Test for statistically significant differences between the variables of the two research groups using the T - student test and Mann-Whitney test algorithms with p < 0.05 corresponding to a 95% confidence interval. The data were analyzed according to medical statistical methods using SPSS 20.0 software. Results: DECT can detect the PA origin in 96.1% of cases, identify atherosclerosis at the root of the artery with a sensitivity of 66.7% and a specificity of 89.5%, and present anastomosis with a sensitivity of 72.7% and a specificity of 72.2%. There is no statistically significant difference in PA diameter on DECT compared to DSA with 95% confidence. Group 2 used DECT for 3D rendering of the PA before PAE had procedure time reduced by 25.8%, fluoroscopy time reduced by 23.2%, dose-area product (DAP) reduced by 25.6%, contrast medium volume reduced by 33.1% compared to group 1 not using DECT, statistically significant with 95% confidence. Conclusion: DECT is a valuable method for planning before PAE to treat BPH. 3D rendering DECT of PA provides anatomical information that minimizes procedure time, fluoroscopy time, dose-area product, and contrast medium volume.


Assuntos
Angiografia Digital , Embolização Terapêutica , Próstata , Hiperplasia Prostática , Humanos , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Masculino , Embolização Terapêutica/métodos , Idoso , Próstata/diagnóstico por imagem , Próstata/irrigação sanguínea , Próstata/patologia , Angiografia Digital/métodos , Pessoa de Meia-Idade , Artérias/diagnóstico por imagem , Resultado do Tratamento , Tomografia Computadorizada por Raios X/métodos
10.
BMC Med Imaging ; 24(1): 212, 2024 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-39134937

RESUMO

BACKGROUND: Prostate cancer is one of the most common malignant tumors in middle-aged and elderly men and carries significant prognostic implications, and recent studies suggest that dual-energy computed tomography (DECT) utilizing new virtual monoenergetic images can enhance cancer detection rates. This study aimed to assess the impact of virtual monoenergetic images reconstructed from DECT arterial phase scans on the image quality of prostate lesions and their diagnostic performance for prostate cancer. METHODS: We conducted a retrospective analysis of 83 patients with prostate cancer or prostatic hyperplasia who underwent DECT scans at Meizhou People's Hospital between July 2019 and December 2023. The variables analyzed included age, tumor diameter and serum prostate-specific antigen (PSA) levels, among others. We also compared CT values, signal-to-noise ratio (SNR), subjective image quality ratings, and contrast-to-noise ratio (CNR) between virtual monoenergetic images (40-100 keV) and conventional linear blending images. Receiver operating characteristic (ROC) curve analyses were performed to evaluate the diagnostic efficacy of virtual monoenergetic images (40 keV and 50 keV) compared to conventional images. RESULTS: Virtual monoenergetic images at 40 keV showed significantly higher CT values (168.19 ± 57.14) compared to conventional linear blending images (66.66 ± 15.5) for prostate cancer (P < 0.001). The 50 keV images also demonstrated elevated CT values (121.73 ± 39.21) compared to conventional images (P < 0.001). CNR values for the 40 keV (3.81 ± 2.13) and 50 keV (2.95 ± 1.50) groups were significantly higher than the conventional blending group (P < 0.001). Subjective evaluations indicated markedly better image quality scores for 40 keV (median score of 5) and 50 keV (median score of 5) images compared to conventional images (P < 0.05). ROC curve analysis revealed superior diagnostic accuracy for 40 keV (AUC: 0.910) and 50 keV (AUC: 0.910) images based on CT values compared to conventional images (AUC: 0.849). CONCLUSIONS: Virtual monoenergetic images reconstructed at 40 keV and 50 keV from DECT arterial phase scans substantially enhance the image quality of prostate lesions and improve diagnostic efficacy for prostate cancer.


Assuntos
Neoplasias da Próstata , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Curva ROC , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Hiperplasia Prostática/diagnóstico por imagem , Idoso de 80 Anos ou mais , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Antígeno Prostático Específico/sangue
11.
Nanomedicine ; 61: 102765, 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38942131

RESUMO

In equine medicine, assisted bone regeneration, including use of biomaterial substitutes like hydroxyapatite (HAP), is crucial for addressing bone defects. To follow-up on the outcome of HAP-based bone defect treatment, the advancement in quantified diagnostic imaging protocols is needed. This study aimed to quantify and compare the radiological properties of the HAP graft and natural equine bone using Magnetic Resonance (MR) and Computed Tomography (CT), both Single (SECT) and Dual Energy (DECT). SECT and DECT, allow for the differentiation of three HAP grain sizes, by progressive increase in relative density (RD). SECT, DECT, and MR enable the differentiation between natural cortical bone and synthetic HAP graft by augmentation in Effective Z and material density (MD) in HAP/Water, Calcium/Water, and Water/Calcium reconstructions, alongside the reduction in T2 relaxation time. The proposed quantification provided valuable radiological insights into the composition of HAP grafts, which may be useful in follow-up bone defect treatment.

12.
BMC Musculoskelet Disord ; 25(1): 557, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39020351

RESUMO

BACKGROUND: This meta-analysis assessed the efficacy of dual-energy computed tomography (DECT) in the diagnosis of anterior cruciate ligament (ACL) injuries. METHODS: The literature search was performed up to December 8, 2023, and included a comprehensive examination of several databases: PubMed, Embase, Cochrane Library, Web of Science, China National Knowledge Infrastructure (CNKI), Wanfang, and VIP. Diagnostic metrics sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and a summary receiver operating characteristic (SROC) were determined using a bivariate model analysis. Heterogeneity within the data was explored through subgroup analyses, which considered variables including geographical region, use of magnetic resonance imaging (MRI), arthroscopy, and study design. RESULTS: The analysis included ten studies encompassing 544 patients. DECT demonstrated substantial diagnostic utility for ACL injuries of the knee, with a sensitivity of 0.91 (95% confidence interval [CI]: 0.88-0.94), a specificity of 0.90 (95% CI: 0.81-0.95), a PLR of 9.20 (95% CI: 4.50-19.00), a NLR of 0.10 (95% CI: 0.06-0.14), a DOR of 97.00 (95% CI: 35.00-268.00), and an area under the curve (AUC) of 0.95 (95% CI: 0.93-0.97). The subgroup analyses consistently showed high diagnostic precision for ACL injuries across Asian population (sensitivity: 0.91, specificity: 0.91, PLR: 9.90, NLR: 0.09, DOR: 105.00, AUC: 0.96), in MRI subgroup (sensitivity: 0.85, specificity: 0.94, PLR: 9.57, NLR: 0.18, DOR: 56.00, AUC: 0.93), in arthroscopy subgroup (sensitivity: 0.92, specificity: 0.89, PLR: 8.40, NLR: 0.09, DOR: 94.00, AUC: 0.95), for prospective studies (sensitivity: 0.92, specificity: 0.88, PLR: 7.40, NLR: 0.09, DOR: 78.00, AUC: 0.95), and for retrospective studies (sensitivity: 0.91, specificity: 0.93, AUC: 0.93). CONCLUSION: DECT exhibits a high value in diagnosing ACL injuries. The significant diagnostic value of DECT provides clinicians with a powerful tool that enhances the accuracy and efficiency of diagnosis and optimizes patient management and treatment outcomes.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomografia Computadorizada por Raios X , Humanos , Ligamento Cruzado Anterior/diagnóstico por imagem , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Traumatismos do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Sensibilidade e Especificidade
13.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38523224

RESUMO

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado de Máquina , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Prognóstico , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Biomarcadores/sangue , Valor Preditivo dos Testes , Estudos Retrospectivos
14.
Emerg Radiol ; 31(1): 73-82, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38224366

RESUMO

PURPOSE: Acute chest syndrome (ACS) is secondary to occlusion of the pulmonary vasculature and a potentially life-threatening complication of sickle cell disease (SCD). Dual-energy CT (DECT) iodine perfusion map reconstructions can provide a method to visualize and quantify the extent of pulmonary microthrombi. METHODS: A total of 102 patients with sickle cell disease who underwent DECT CTPA with perfusion were retrospectively identified. The presence or absence of airspace opacities, segmental perfusion defects, and acute or chronic pulmonary emboli was noted. The number of segmental perfusion defects between patients with and without acute chest syndrome was compared. Sub-analyses were performed to investigate robustness. RESULTS: Of the 102 patients, 68 were clinically determined to not have ACS and 34 were determined to have ACS by clinical criteria. Of the patients with ACS, 82.4% were found to have perfusion defects with a median of 2 perfusion defects per patient. The presence of any or new perfusion defects was significantly associated with the diagnosis of ACS (P = 0.005 and < 0.001, respectively). Excluding patients with pulmonary embolism, 79% of patients with ACS had old or new perfusion defects, and the specificity for new perfusion defects was 87%, higher than consolidation/ground glass opacities (80%). CONCLUSION: DECT iodine map has the capability to depict microthrombi as perfusion defects. The presence of segmental perfusion defects on dual-energy CT maps was found to be associated with ACS with potential for improved specificity and reclassification.


Assuntos
Síndrome Torácica Aguda , Anemia Falciforme , Iodo , Embolia Pulmonar , Humanos , Síndrome Torácica Aguda/diagnóstico por imagem , Estudos Retrospectivos , Angiografia/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Pulmão , Embolia Pulmonar/diagnóstico por imagem , Anemia Falciforme/complicações , Anemia Falciforme/diagnóstico por imagem , Perfusão
15.
Radiol Med ; 129(5): 677-686, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38512626

RESUMO

PURPOSE: To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer. METHODS: This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations. RESULTS: Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs. CONCLUSIONS: The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.


Assuntos
Neoplasias Pancreáticas , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Valor Preditivo dos Testes
16.
Radiol Med ; 129(7): 967-976, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38869829

RESUMO

PURPOSE: To evaluate the efficacy of volumetric CT attenuation-based parameters obtained through automated 3D organ segmentation on virtual non-contrast (VNC) images from dual-energy CT (DECT) for assessing hepatic steatosis. MATERIALS AND METHODS: This retrospective study included living liver donor candidates having liver DECT and MRI-determined proton density fat fraction (PDFF) assessments. Employing a 3D deep learning algorithm, the liver and spleen were automatically segmented from VNC images (derived from contrast-enhanced DECT scans) and true non-contrast (TNC) images, respectively. Mean volumetric CT attenuation values of each segmented liver (L) and spleen (S) were measured, allowing for liver attenuation index (LAI) calculation, defined as L minus S. Agreements of VNC and TNC parameters for hepatic steatosis, i.e., L and LAI, were assessed using intraclass correlation coefficients (ICC). Correlations between VNC parameters and MRI-PDFF values were assessed using the Pearson's correlation coefficient. Their performance to identify MRI-PDFF ≥ 5% and ≥ 10% was evaluated using receiver operating characteristic (ROC) curve analysis. RESULTS: Of 252 participants, 56 (22.2%) and 16 (6.3%) had hepatic steatosis with MRI-PDFF ≥ 5% and ≥ 10%, respectively. LVNC and LAIVNC showed excellent agreement with LTNC and LAITNC (ICC = 0.957 and 0.968) and significant correlations with MRI-PDFF values (r = - 0.585 and - 0.588, Ps < 0.001). LVNC and LAIVNC exhibited areas under the ROC curve of 0.795 and 0.806 for MRI-PDFF ≥ 5%; and 0.916 and 0.932, for MRI-PDFF ≥ 10%, respectively. CONCLUSION: Volumetric CT attenuation-based parameters from VNC images generated by DECT, via automated 3D segmentation of the liver and spleen, have potential for opportunistic hepatic steatosis screening, as an alternative to TNC images.


Assuntos
Fígado Gorduroso , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Estudos Retrospectivos , Masculino , Feminino , Fígado Gorduroso/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Pessoa de Meia-Idade , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Doadores Vivos , Fígado/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Baço/diagnóstico por imagem , Curva ROC
17.
J Stroke Cerebrovasc Dis ; 33(6): 107673, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38458504

RESUMO

BACKGROUND: Blood brain barrier disruption (BBBD) can be visualized by contrast extravasation (CE) after endovascular treatment (EVT) in patients with acute ischemic stroke. Elevated blood pressure is a risk factor for BBBD. However, the association between procedural blood pressure and CE post-EVT is unknown. METHODS: In this single-center retrospective study, we analyzed 501 eligible patients who received a dual energy CT (DECT) immediately post-EVT for acute ischemic stroke. Procedural blood pressure values (SBPmean, SBPmax, SBPmax-min, and MAPmean) were collected. CE was quantified by measuring the maximum parenchymal iodine concentration on DECT iodine overlay map reconstructions. As a measure for the extent of BBBD, we created CE-ASPECTS by deducting one point per hyperdense ASPECTS region on iodine overlay maps. The association between blood pressure and CE was assessed using multivariable linear regression. RESULTS: The procedural SBPmean, SBPmax, and MAPmean were 150 ± 26 mmHg, 173 ± 29 mmHg, and 101 ± 17 mmHg, respectively. The median maximum iodine concentration on post-EVT DECT was 1.2 mg/ml (IQR 0.7-2.0), and median CE-ASPECTS was 8 (IQR 5-11). The maximum iodine concentration was not associated with blood pressure. SBPmean, SBPmax, and MAPmean were significantly associated with CE-ASPECTS (per 10 mmHg, ß = -0.2, 95 % CI -0.31 to -0.09, ß = -0.15, 95 % CI -0.25 to -0.06, ß = -0.33, 95 % CI -0.49 to -0.17, respectively). CONCLUSION: In acute ischemic stroke patients undergoing EVT, particularly in patients achieving successful recanalization, SBPmean, SBPmax, and MAPmean are associated with the extent of BBBD on immediate post-EVT DECT, but not with maximum iodine concentration.


Assuntos
Pressão Sanguínea , Meios de Contraste , Procedimentos Endovasculares , Extravasamento de Materiais Terapêuticos e Diagnósticos , AVC Isquêmico , Valor Preditivo dos Testes , Humanos , Feminino , Masculino , Estudos Retrospectivos , Idoso , Procedimentos Endovasculares/efeitos adversos , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Fatores de Risco , AVC Isquêmico/fisiopatologia , AVC Isquêmico/terapia , AVC Isquêmico/diagnóstico por imagem , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada , Tomografia Computadorizada por Raios X
18.
J Xray Sci Technol ; 32(3): 549-568, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640141

RESUMO

BACKGROUND: Projection Domain Decomposition (PDD) is a dual energy reconstruction method which implements the decomposition process before image reconstruction. The advantage of PDD is that it can alleviate beam hardening artifacts and metal artifacts effectively as energy spectra estimation is considered in PDD. However, noise amplification occurs during the decomposition process, which significantly impacts the accuracy of effective atomic number and electron density. Therefore, effective noise reduction techniques are required in PDD. OBJECTIVE: This study aims to develop a new algorithm capable of minimizing noise while simultaneously preserving edges and fine details. METHODS: In this study, a denoising algorithm based on low rank and similarity-based regularization (LRSBR) is presented. This algorithm incorporates the low-rank characteristic of tensors into similarity-based regularization (SBR) framework. This method effectively addresses the issue of instability in edge pixels within the SBR algorithm and enhances the structural consistency of dual-energy images. RESULTS: A series of simulation and practical experiments were conducted on a dual-layer dual-energy CT system. Experiments demonstrate that the proposed method outperforms exiting noise removal methods in Peak Signal-to-noise Ratio (PSNR), Root Mean Square Error (RMSE), and Structural Similarity (SSIM). Meanwhile, there has been a notable enhancement in the visual quality of CT images. CONCLUSIONS: The proposed algorithm has a significantly improved noise reduction compared to other competing approach in dual-energy CT. Meanwhile, the LRSBR method exhibits outstanding performance in preserving edges and fine structures, making it practical for PDD applications.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Simulação por Computador
19.
Artigo em Inglês | MEDLINE | ID: mdl-37688559

RESUMO

OBJECTIVES: In 2015, the 20-item Tophus Impact Questionnaire (TIQ-20) was developed as a tophus-specific patient reported outcome measure. The aim of this study was to determine whether TIQ-20 scores change during urate-lowering therapy. METHODS: We analysed data from a two-year clinical trial of allopurinol dose escalation using a treat-to-target serum urate approach. For participants with tophaceous gout, the longest diameter of up to three index tophi was measured using Vernier calipers and the TIQ-20 was recorded at study visits. Participants at the one site were invited into a dual energy CT (DECT) sub-study. Participants were included in this analysis if they had tophaceous gout and TIQ-20 scores available at baseline, Year 1, and Year 2 (n = 58, 39 with DECT data). Data were analysed using mixed model approach to repeated measures. RESULTS: Improvements were observed in all tophus measures over the two-year period. The mean (SD) TIQ-20 scores reduced over two years from 3.59 (1.77)-2.46 (1.73), P< 0.0001, and the mean (95%CI) TIQ-20 change over the two years was -1.13 (-1.54, -0.71). Effect size (Cohen's d) for the change in the sum of the index tophi diameter over two years was 0.68, for DECT urate volume was 0.50, and for the TIQ-20 was 0.71. CONCLUSION: For people with tophaceous gout treated with allopurinol using a treat to target serum urate approach, improvements in TIQ-20 occur, as well as improvements in physical and imaging tophus measures. These findings demonstrate that the TIQ-20 is a responsive patient-reported instrument of tophus impact.

20.
Osteoporos Int ; 34(9): 1549-1559, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37286662

RESUMO

Identifying the full scope of pelvic fracture patterns in older adults has gained clinical importance since the last decennium. CT is recommended as the golden standard; however, MRI has even greater diagnostic accuracy. Dual energy computed tomography (DECT) is a new and promising imaging technique, but the diagnostic accuracy in the context of pelvic fragility fractures (FFPs) has not been widely established. The aim was to provide insight into the diagnostic accuracy of different imaging techniques and the relevance for clinical practice. A systematic search was performed in the PubMed database. All studies that reported on CT, MRI or DECT imaging techniques in older adults who suffered a pelvic fracture were reviewed and, if relevant, included. Eight articles were included. In up to 54% of the patients, additional fractures were found on MRI compared to CT, and in up to 57% of the patients on DECT. The sensitivity of DECT for posterior pelvic fracture detection was similar to MRI. All patients without fractures on CT appeared to have posterior fractures on MRI. After additional MRI, 40% of the patients had a change of classification. DECT and MRI showed very similar results in terms of diagnostic accuracy. Over a third of all patients appear to have a more severe fracture classification after MRI, the majority changing to Rommens type 4. However, in only a few patients who changed of fracture classification, a change of therapy was advised. This review suggests that MRI and DECT scans are superior in diagnosing FFPs.


Assuntos
Fraturas Ósseas , Ossos Pélvicos , Humanos , Idoso , Tomografia Computadorizada por Raios X/métodos , Fraturas Ósseas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ossos Pélvicos/diagnóstico por imagem , Cintilografia , Sensibilidade e Especificidade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA