RESUMO
Diagnosis and management of cardiac complications of cancer treatment can be challenging. Few PET data suggest a potential role of dynamic perfusion imaging with measurements of absolute myocardial blood flow and flow reserve (MFR). We report the case of a 72-year-old woman with a history of bilateral breast cancer who underwent dynamic cardiac scintigraphy. Relative perfusion analysis was normal, whereas MFR was impaired in all territories suggesting diffuse microvascular dysfunction. Flow parameters derived from dynamic cardiac scintigraphy could thus be an interesting tool in cardio-oncology.
Assuntos
Neoplasias da Mama , Circulação Coronária , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Feminino , Idoso , Neoplasias da Mama/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo MiocárdicoRESUMO
Dynamic acquisition allows absolute quantification of myocardial perfusion and flow reserve, offering an alternative to overcome the potential limits of relative quantification, especially in patients with balanced multivessel coronary artery disease. SPECT myocardial perfusion is widely available, at lower cost than PET. Dynamic cardiac SPECT is now feasible and has the potential to be the next step of comprehensive perfusion imaging. In order to help nuclear cardiologists potentially interested in using dynamic perfusion SPECT, we sought to review the different steps of acquisition, processing, and reporting of dynamic SPECT studies in order to enlighten the potentially critical pitfalls and artifacts. Both patient-related and technical artifacts are discussed. Key parameters of the acquisition include pharmacological stress, radiopharmaceuticals, and injection device. When it comes to image processing, attention must be paid to image-derived input function, patient motion, and extra-cardiac activity. This review also mentions compartment models, cameras, and attenuation correction. Finally, published data enlighten some facets of dynamic cardiac SPECT while several issues remain. Harmonizing acquisition and quality control procedures will likely improve its performance and clinical strength.
Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Humanos , Artefatos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Compostos Radiofarmacêuticos , Perfusão , Imagem de Perfusão do Miocárdio/métodosRESUMO
BACKGROUND: The aim of this study was to investigate the feasibility and diagnostic value of myocardial flow reserve (MFR) assessed by rest/stress myocardial perfusion imaging with dynamic single-photon emission computed tomography (SPECT) in the functional evaluation of myocardial bridge (MB). METHODS: From May 2017 to July 2021, patients with angiographically confirmed isolated MB on the left anterior descending artery (LAD) who underwent dynamic SPECT myocardial perfusion imaging were retrospectively included. The assessment of semiquantitative indices of myocardial perfusion (summed stress scores, SSS) and quantitative parameters (MFR) was performed. RESULTS: A total of 49 patients were enrolled. The mean age of the subjects was 61.0 ± 9.0 years. All of the patients were symptomatic, and 16 cases (32.7%) presented with typical angina. SPECT-derived MFR showed a borderline significantly negative correlation with SSS (r = 0.261, P = .070). There was a trend of higher prevalence of impaired myocardial perfusion defined as MFR < 2 than as SSS ≥ 4 (42.9% vs 26.5%; P = .090). CONCLUSION: Our data support that SPECT MFR may be a useful parameter for the functional assessment of MB. In patients with MB, the use of dynamic SPECT could be a potential method for hemodynamic assessment.
Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Ponte Miocárdica , Imagem de Perfusão do Miocárdio , Humanos , Pessoa de Meia-Idade , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Perfusão , Imagem de Perfusão do Miocárdio/métodos , Circulação CoronáriaRESUMO
BACKGROUND: Whether physiological coronary diffuseness assessed by quantitative flow reserve (QFR) pullback pressure gradient (PPG) correlates with longitudinal myocardial blood flow (MBF) gradient and improves diagnostic performances for myocardial ischemia remains unknown. METHODS AND RESULTS: MBF was measured in mL g-1 min-1 with 99mTc-MIBI CZT-SPECT at rest and stress, corresponding myocardial flow reserve (MFR = MBF stress/MBF rest) and relative flow reserve (RFR = MBF stenotic area/MBF reference) were calculated. Longitudinal MBF gradient was defined as apical and basal left ventricle MBF gradient. â³longitudinal MBF gradient was calculated by longitudinal MBF gradient at stress and rest. QFR-PPG was acquired from virtual QFR pullback curve. QFR-PPG significantly correlated with hyperemic longitudinal MBF gradient (r = 0.45, P = 0.007) and â³longitudinal MBF gradient (stress-rest) (r = 0.41, P = 0.016). Vessels with lower RFR had lower QFR-PPG (0.72 vs. 0.82, P = 0.002), hyperemic longitudinal MBF gradient (1.14 vs. 2.22, P = 0.003) and â³longitudinal MBF gradient (0.50 vs. 1.02, P = 0.003). QFR-PPG, hyperemic longitudinal MBF gradient and â³longitudinal MBF gradient showed comparable diagnostic performances for predicting decreased RFR (area under curve [AUC]: 0.82 vs. 0.81 vs. 0.75, P = NS) or QFR (AUC: 0.83 vs. 0.72 vs. 0.80, P = NS). In addition, QFR-PPG and QFR in combination showed incremental value compared with QFR for predicting RFR (AUC = 0.83 vs. 0.73, P = 0.046, net reclassification index = 0.508, P = 0.001). CONCLUSION: QFR-PPG significantly correlated with longitudinal MBF gradient and â³longitudinal MBF gradient when used for physiological coronary diffuseness assessment. All three parameters had high accuracy in predicting RFR or QFR. Adding physiological diffuseness assessment increased accuracy for predicting myocardial ischemia.
Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Imagem de Perfusão do Miocárdio , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Angiografia Coronária/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Coração , Imagem de Perfusão do Miocárdio/métodos , Valor Preditivo dos TestesRESUMO
BACKGROUND: The aim of this study was to investigate the correlation of coronary flow reserve (CFR) assessed by rest/stress myocardial perfusion imaging with dynamic single-photon emission computed tomography (SPECT) with intracoronary pressure-derived fractional flow reserve (FFR) in patients with single-vessel coronary artery disease (CAD). METHODS: Patients with suspected or known stable CAD who were referred for invasive coronary angiography were prospectively enrolled. Both invasive FFR and SPECT were performed in subjects with single-vessel intermediate coronary stenosis. A cutoff value of < 0.8 was used to define abnormal FFR. RESULTS: A total of 34 patients were enrolled. The mean age of the subjects was 62.1 ± 6.7 years, and 79.4% were male. SPECT-derived CFR showed a significantly moderate correlation with FFR (r = 0.505, P = .003). The diagnostic performance for the identification of abnormal FFR in terms of sensitivity, specificity, and accuracy was 88.9%, 83.3%, and 87.9%, respectively, for CFR, with an optimized cutoff value of 1.73. CONCLUSION: In patients with single-vessel CAD, SPECT CFR was useful for the detection of functionally significant stenosis. Our data support the use of this technique as an optional method for hemodynamic assessment, especially when FFR results are in normal range.
Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodosRESUMO
BACKGROUND: Measurement of myocardial blood flow (MBF) is feasible using SPECT imaging but the acquisition requires more time than usual. Our study assessed the impact of reducing acquisition times on the accuracy and repeatability of the uptake rate constant (K1). METHODS: Twenty-nine patients underwent two rest/stress studies with Tc-99m-tetrofosmin 18 ± 13 days apart, using a one-day rest/stress dynamic SPECT imaging protocol with a solid-state cardiac camera. A 5-minute static image was acquired prior to tracer injection for subtraction of residual activity, followed immediately by 11-minute of list-mode data collection. Static image acquisition times of 0.5, 1, and 3 minutes and dynamic imaging times of 5, 7, and 9 minutes were simulated by truncating list-mode data. Images were reconstructed with/without attenuation correction and with/without motion correction. Kinetic parameters were calculated using a 1-tissue-compartment model. RESULTS: K1 increased with reduced dynamic but not static imaging time (P < 0.001). The increase in K1 for a 9-minute scan was small (4.7 ± 5.3%) compared with full-length studies. The repeatability of K1 did not change significantly (13 ± 12%, P > 0.17). CONCLUSIONS: A shortened imaging protocol of 3-minute (rest) or 30-second (stress) static image acquisition and 9 minutes of dynamic image acquisition altered K1 by less than 5% compared to a previously validated 11-minute acquisition.
Assuntos
Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de TempoRESUMO
BACKGROUND: We measured myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) by a dynamic low-dose CZT-SPECT protocol in patients with suspected or known coronary artery disease (CAD) and investigated the capability of dynamic data in predicting obstructive CAD. A total of 173 patients with suspected or known CAD underwent dynamic CZT-SPECT after the injection of 155 MBq and 370 MBq of 99mTc-sestamibi for rest and stress imaging, respectively. Standard rest and stress imaging were performed at the end of each dynamic scan. A total perfusion defect (TPD) < 5% were considered normal. Obstructive CAD was defined as ≥ 70% stenosis at coronary angiography. RESULTS: Global MPR was lower (p < 0.05) in patients with abnormal compared with those with normal MPI (2.40 ± 0.7 vs. 2.70 ± 0.8). A weak, albeit significant correlation between TPD and MPR (r = - 0.179, p < 0.05) was found. In 91 patients with available angiographic data, hyperemic MBF (2.59 ± 1.2 vs. 3.24 ± 1.1 ml/min/g) and MPR (1.96 ± 0.7 vs. 2.74 ± 0.9) were lower (both p < 0.05) in patients with obstructive CAD (n = 21) compared with those without (n = 70). At univariable analysis, TPD, hyperemic MBF, and MPR were significant predictors of obstructive CAD, whereas only MPR was independent predictor at multivariable analysis (p < 0.05). At per vessels analysis, regional hyperemic MBF (2.59 ± 1.2 vs. 3.24 ± 1.1 ml/min/g) and regional MPR (1.96 ± 0.7 vs. 2.74 ± 0.9) were lower in the 31 vessels with obstructive CAD compared with 242 vessels without (both p < 0.05). CONCLUSIONS: In patients with suspected or known CAD, MPR assessed by low-dose dynamic CZT-SPECT showed a good correlation with myocardial perfusion imaging findings and it could be useful to predict obstructive CAD.
Assuntos
Doença da Artéria Coronariana , Imagem de Perfusão do Miocárdio , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/instrumentação , Imagem de Perfusão do Miocárdio/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton ÚnicoRESUMO
BACKGROUND: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). METHODS: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of 99mTc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. RESULTS: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). CONCLUSIONS: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tecnécio Tc 99m SestamibiRESUMO
PURPOSE: We assessed the feasibility of myocardial blood flow (MBF) and flow reserve (MFR) estimation using dynamic SPECT with a novel CZT camera in patients with stable CAD, in comparison with 15O-water PET and fractional flow reserve (FFR). METHODS: Thirty patients were prospectively included and underwent FFR measurements in the main coronary arteries (LAD, LCx, RCA). A stenosis ≥50% was considered obstructive and a FFR abnormal if ≤0.8. All patients underwent a dynamic rest/stress 99mTc-sestamibi CZT-SPECT and 15O-water PET for MBF and MFR calculation. Net retention kinetic modeling was applied to SPECT data to estimate global uptake values, and MBF was derived using Leppo correction. Ischemia by PET and CZT-SPECT was considered present if MFR was lower than 2 and 2.1, respectively. RESULTS: CZT-SPECT yielded higher stress and rest MBF compared to PET for global and LAD and LCx territories, but not in RCA territory. MFR was similar in global and each vessel territory for both modalities. The sensitivity, specificity, accuracy, positive and negative predictive value of CZT-SPECT were, respectively, 83.3, 95.8, 93.3, 100 and 85.7% for the detection of ischemia and 58.3, 84.6, 81.1, 36.8 and 93% for the detection of hemodynamically significant stenosis (FFR ≤ 0.8). CONCLUSIONS: Dynamic 99mTc-sestamibi CZT-SPECT was technically feasible and provided similar MFR compared to 15O-water PET and high diagnostic value for detecting impaired MFR and abnormal FFR in patients with stable CAD.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Angiografia Coronária , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio , ÁguaRESUMO
OBJECTIVES: The aim of this study was to evaluate the accuracy of myocardial blood flow (MBF) quantitation of 99mTc-Sestamibi (MIBI) single photon emission computed tomography (SPECT) compared with 13N-Ammonia (NH3) position emission tomography (PET) on the same cohorts. BACKGROUND: Recent advances of SPECT technologies have been applied to develop MBF quantitation as a promising tool to diagnose coronary artery disease (CAD) for areas where PET MBF quantitation is not available. However, whether the SPECT approach can achieve the same level of accuracy as the PET approach for clinical use still needs further investigations. METHODS: Twelve healthy volunteers (HVT) and 16 clinical patients with CAD received both MIBI SPECT and NH3 PET flow scans. Dynamic SPECT images acquired with high temporary resolution were fully corrected for physical factors and processed to quantify K1 using the standard compartmental modeling. Human MIBI tracer extraction fraction (EF) was determined by comparing MIBI K1 and NH3 flow on the HVT group and then used to convert flow values from K1 for all subjects. MIBI and NH3 flow values were systematically compared to validate the SPECT approach. RESULTS: The human MIBI EF was determined as [1.0-0.816*exp(-0.267/MBF)]. Global and regional MBF and myocardial flow reserve (MFR) of MIBI SPECT and NH3 PET were highly correlated for all subjects (global R2: MBF = 0.92, MFR = 0.78; regional R2: MBF ≥ 0.88, MFR ≥ 0.71). No significant differences for rest flow, stress flow, and MFR between these two approaches were observed (All p ≥ 0.088). Bland-Altman plots overall revealed small bias between MIBI SPECT and NH3 PET (global: ΔMBF = -0.03Lml/min/g, ΔMFR = 0.07; regional: ΔMBF = -0.07 - 0.06 , ΔMFR = -0.02 - 0.22). CONCLUSIONS: Quantitation with SPECT technologies can be accurate to measure myocardial blood flow as PET quantitation while comprehensive imaging factors of SPECT to derive the variability between these two approaches were fully addressed and corrected.
Assuntos
Amônia , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária , Tomografia por Emissão de Pósitrons/métodos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio/métodos , Radioisótopos de Nitrogênio , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). METHODS: Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. RESULTS: The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). CONCLUSIONS: Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.
Assuntos
Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Compostos Organofosforados , Compostos de Organotecnécio , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
INTRODUCTION: This study investigated the performance of SPECT myocardial blood flow (MBF) quantitation lacking full physical corrections (All Corr) in dynamic SPECT (DySPECT) images. METHODS: Eleven healthy normal volunteers (HVT) and twenty-four patients with angiography-documented CAD were assessed. All Corr in 99mTc-sestamibi DySPECT encompassed noise reduction (NR), resolution recovery (RR), and corrections for scatter (SC) and attenuation (AC), otherwise no correction (NC) or only partial corrections. The performance was evaluated by quality index (R 2) and blood-pool spillover index (FBV) in kinetic modeling, and by rest flow (RMBF) and stress flow (SMBF) compared with those of All Corr. RESULTS: In HVT group, NC diminished 2-fold flow uniformity with the most degraded quality (15%-18% reduced R 2) and elevated spillover effect (45%-50% increased FBV). Consistently higher RMBF and SMBF were discovered in both groups (HVT 1.54/2.31 higher; CAD 1.60/1.72; all P < .0001). Bland-Altman analysis revealed positive flow bias (HVT 0.9-2.6 mL/min/g; CAD 0.7-1.3) with wide ranges of 95% CI of agreement (HVT NC -1.9-7.1; NR -0.4-4.4; NR + SC -1.1-4.3; NR + SC + RR -0.7-2.5) (CAD NC -1.2-3.8; NR -1.0-2.8; NR + SC -1.0-2.5; NR + SC + RR -1.1-2.6). CONCLUSIONS: Uncorrected physical interference in DySPECT images can extensively impact the performance of MBF quantitation. Full physical corrections should be considered to warrant this tool for clinical utilization.
Assuntos
Circulação Coronária , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Pessoa de Meia-IdadeRESUMO
(1) Background: The objective of this study was to determine the optimal post-processing model for dynamic cadmium-zinc-telluride single-photon emission computed tomography (CZT-SPECT). (2) Methods: A total of 235 patients who underwent diagnostic invasive coronary angiography within three months of the SPECT and those who had coronary computed tomography angiography (CCTA) before SPECT (within 3 months) were enrolled in this study. Each SPECT study was processed to obtain global and regional stress myocardial blood flow (sMBF), rest-MBF (rMBF), myocardial flow reserve (MFR) and flow difference (FD) estimates obtained with 1-tissue-compartment (1TCM) and net retention (NR) modes, both with and without attenuation correction. (3) Results: The use of AC led to significantly higher sMBF, rMBF and DF values obtained by 1TCM compared those values derived by 1TCM with NAC; the lowest values of stress MBF and rest MBF were obtained by 1TCM_NAC. The resting flow, MFR and DF were significantly (p < 0.005) higher in the AC model than in NAC. All quantitative variables were significantly (p < 0.05) higher in NR_NAC than in the 1TC_NAC model. Finally, sMBF, rMBF and FD showed significantly (p < 0.05) higher values by using 1TMC_AC compared to NR_AC. (4) Conclusions: We suggested that 1-compartment and net retention models correctly reflect coronary microcirculation and can be used for clinical practice for evaluating quantitative myocardial perfusion by dynamic SPECT. Attenuation correction is an important step in post-processing dynamic SPECT data, which increases the consistency and diagnostic accuracy of models.
RESUMO
Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.
RESUMO
Objectives: The purpose of this study was to validate undersampled single-photon emission computed tomography (SPECT) imaging using a combination of compressed sensing (CS) iterative reconstruction (CS-IR) and offset acquisition. Methods: Three types of numerical phantoms were used to evaluate image quality and quantification derived from CS with offset acquisition. SPECT images were reconstructed using filtered back-projection (FBP), maximum likelihood-expectation maximization (ML-EM), CS-IR, and CS-IR with offset acquisition. The efficacy of CS-IR with offset acquisition was examined in terms of spatial resolution, aspect ratio (ASR), activity concentration linearity, contrast, percent coefficient of variation (%CV), and specific binding ratio (SBR). Results: The full widths at half maximum remained unchanged as the number of projections decreased in CS-IR with offset acquisition. Changes in ASRs and linearities of count density were observed for ML-EM and CS-IR from undersampled projections. The %CV obtained by CS-IR with offset acquisition was substantially lower than that obtained by ML-EM and CS-IR. There were no significant differences between the %CVs obtained from 60 projections by CS-IR with offset acquisition and from 120 projections by FBP. Although the SBRs for CS-IR with offset acquisition tended to be slightly lower than for FBP, the SBRs for CS-IR with offset acquisition did not change with the number of projections. Conclusions: CS-IR with offset acquisition can provide good image quality and quantification compared with a commonly used SPECT reconstruction method, especially from undersampled projection data. Our proposed method could shorten overall SPECT acquisition times, which would benefit patients and enable quantification with dynamic SPECT acquisitions.
RESUMO
Heart disease is the second most common cause of mortality in Taiwan, mainly coronary artery disease (CAD).Quantitative coronary blood flow has been collected by dynamic single-photon emission computed tomography (Dynamic SPECT/CT) for CAD diagnosis in previous studies. However, few studies defined the extent of left ventricle (LV) ischemia on Dynamic SPECT/CT for predicting significant coronary artery stenosis. This study evaluates the extent of LV ischemic blockage in patients suspected of CAD who were referred by cardiologists. A total of 181 patients with suspected CAD were enrolled. They underwent 99mTc-Sestamibi (MIBI) Dynamic SPECT/CT survey before cardiac intervention. Dynamic SPECT/CT has better sensitivity (88%), specificity (96%), and accuracy (94%) compared with those of semi-quantitative MIBI MPI (more than 10%). Results indicated that5% of the LV ischemic extent can yield positive PCI results (>70% stenosis in coronary arteries) compared with the moderate abnormal extent of at least 15% of LV. When the percentage of combined moderate abnormal extent and ischemia extent of LV reaches 27.3%, positive PCI results may be indicated. This study revealed Dynamic SPECT/CT has greater sensitivity, specificity, and accuracy as compared with MPI. Thus, the severity of abnormal perfusion extent of LV on Dynamic SPECT/CT might be beneficial to predict positive PCI results in patients with significant suspicion CAD.
RESUMO
This paper presents a review of the literature concerning the clinical application of modern semiconductor (CZT) gamma cameras in the radioinuclide diagnosis of coronary artery disease. It contains information on the diagnostic efficacy of myocardial perfusion studies performed with those cameras compared with the widely used scintillation (Anger) cameras, an overview of their effectiveness in comparison with coronary angiography (also fractional flow reserve) and currently available clinical results of a myocardial flow reserve measured with a dynamic SPECT study. Introduction of this imaging modality to the measurement of a myocardial flow reserve aims to facilitate access to this type of study compared to the less available and more expensive PET method used so far.
RESUMO
We present a case of CAD with anteroseptal MI after stent insertion for revascularization due to symptoms presented. MPI with dynamic SPECT/CT provided useful information in terms of flow parameters and matched territories of stenting results as well as providing coronary artery flow phenomenon underwent PCI. In this case, dynamic SPECT/CT may minimize errors with proper stents treatment, especially for controversial MPI results.
RESUMO
In our recent work, we proposed an image reconstruction procedure aimed to unify gated imaging and dynamic imaging in nuclear cardiac imaging. With this procedure the goal is to obtain an image sequence from a single acquisition which shows simultaneously both cardiac motion and tracer distribution change over the course of imaging. In this work, we further develop and demonstrate this procedure for fully 5D (3D space plus time plus gate) reconstruction in gated, dynamic cardiac SPECT imaging, where the challenge is even greater without the use of multiple fast camera rotations. For 5D reconstruction, we develop and compare two iterative algorithms: one is based on the modified block sequential regularized EM (BSREM-II) algorithm, and the other is based on the one-step late (OSL) algorithm. In our experiments, we simulated gated cardiac imaging with the NURBS-based cardiac-torso (NCAT) phantom and Tc99m-Teboroxime as the imaging agent, where acquisition with the equivalent of only three full camera rotations was used during the course of a 12-minute postinjection period. We conducted a thorough evaluation of the reconstruction results using a number of quantitative measures. Our results demonstrate that the 5D reconstruction procedure can yield gated dynamic images which show quantitative information for both perfusion defect detection and cardiac motion.
RESUMO
The aim of this study was to evaluate the effects of the acquisition rotation speed and the rotation time for continuous repetitive rotation acquisition (CRRA) on image quality and quantification in 123I-FP-CIT SPECT. Methods: An anthropomorphic striatal phantom filled with 123I solution was acquired with CRRA and the step-and-shoot (SS) mode. The following combinations of acquisition rotation speed and rotation time for CRRA were used: 0.50 rpm by 30 frames, 0.17 rpm by 10 frames, 0.10 rpm by 6 frames, and 0.05 rpm by 3 frames. SPECT images were reconstructed using ordered-subset expectation maximization with resolution recovery, scatter, and CT-based attenuation correction. Two kinds of image processing patterns-image reconstruction after the addition of projection data (the added-projection-data process) and image addition after data reconstruction (the added-reconstructed-image process)-were investigated in this study. The effects of the acquisition parameters and the image processes were evaluated by the full width at half maximum, percentage coefficient of variation (%CV), and specific binding ratio (SBR). Results: With full width at half maximum, there were no clear differences between CRRA images obtained with the various rotation speeds before rotation and the SS mode. Although the combination of a slow rotation speed and a short rotation time improved image uniformity compared with the SS mode, the %CV obtained by CRRA increased as the rotation speed increased. The %CVs were 11.9% ± 0.9% for 0.50 rpm by 30 frames, 6.9% ± 0.9% for 0.05 rpm by 3 frames, and 9.6% ± 0.5% for SS mode. SBRs obtained by CRRA with the added-projection-data process were equal to those obtained by SS mode. However, SBRs obtained with the added-reconstructed-image process were clearly decreased compared with the SS mode. Conclusion: The combination of rotation speed and rotation times affects the image quality and quantification of 123I-FP-CIT SPECT using CRRA. When CRRA is applied in 123I-FP-CIT SPECT, it is necessary to use added-projection-data processes and proper rotation speeds (e.g., 0.10-0.17 rpm rotation speed).