Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Mol Sci ; 24(3)2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36768695

RESUMO

Epigenetic immune cell counting is a DNA (de)methylation-based technique which can be used to quantify lymphocyte subsets on dried blood spots (DBS). The foregoing techniques allow for a retrospective investigation of immune cell profiles in newborns. In this study, we used this technique for determining lymphocyte subcounts as a potential biomarker for necrotizing enterocolitis (NEC). We investigated whether this technique can be implemented in the field of neonatology, by testing whether regulatory T cell (Treg) levels are pre-existently low in preterms with NEC. Newborn screening (NBS) cards from 32 preterms with NEC and 32 age- and weight-matched preterm controls, and 60 healthy term newborns, were analyzed. Relative and absolute cell counts were determined for CD3+, CD4+, CD8+, Th17, and Treg T cells. For both relative and absolute cell counts of CD3+, CD4+, CD8+, and Th17 T cells, significant differences were found between healthy term controls and both preterm groups, but not between preterm groups. For Tregs, no significant differences were found in either relative or absolute counts between any of the newborn groups. This study demonstrates the principle of epigenetic immune cell counting to analyze lymphocyte subsets in preterm neonates.


Assuntos
Enterocolite Necrosante , Doenças Fetais , Doenças do Recém-Nascido , Lactente , Feminino , Recém-Nascido , Humanos , Recém-Nascido Prematuro , Estudos Retrospectivos , Enterocolite Necrosante/diagnóstico , Enterocolite Necrosante/genética , Biomarcadores , Contagem de Linfócitos , Epigênese Genética
2.
J Clin Immunol ; 41(8): 1762-1773, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34370170

RESUMO

PURPOSE: Newborn screening (NBS) for severe combined immunodeficiency (SCID) is based on the detection of T-cell receptor excision circles (TRECs). TRECs are a sensitive biomarker for T-cell lymphopenia, but not specific for SCID. This creates a palette of secondary findings associated with low T-cells that require follow-up and treatment or are non-actionable. The high rate of (non-actionable) secondary findings and false-positive referrals raises questions about the harm-benefit-ratio of SCID screening, as referrals are associated with high emotional impact and anxiety for parents. METHODS: An alternative quantitative TREC PCR with different primers was performed on NBS cards of referred newborns (N = 56) and epigenetic immune cell counting was used as for relative quantification of CD3 + T-cells (N = 59). Retrospective data was used to determine the reduction in referrals with a lower TREC cutoff value or an adjusted screening algorithm. RESULTS: When analyzed with a second PCR with different primers, 45% of the referrals (25/56) had TREC levels above cutoff, including four false-positive cases in which two SNPs were identified. With epigenetic qPCR, 41% (24/59) of the referrals were within the range of the relative CD3 + T-cell counts of the healthy controls. Lowering the TREC cutoff value or adjusting the screening algorithm led to lower referral rates but did not prevent all false-positive referrals. CONCLUSIONS: Second tier tests and adjustments of cutoff values or screening algorithms all have the potential to reduce the number of non-actionable secondary findings in NBS for SCID, although second tier tests are more effective in preventing false-positive referrals.


Assuntos
Imunodeficiência Combinada Severa/diagnóstico , Algoritmos , Reações Falso-Positivas , Humanos , Recém-Nascido , Triagem Neonatal , Receptores de Antígenos de Linfócitos T/genética , Receptores de Antígenos de Linfócitos T/imunologia , Imunodeficiência Combinada Severa/genética , Imunodeficiência Combinada Severa/imunologia
3.
Int J Neonatal Screen ; 7(4)2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34842618

RESUMO

Newborn screening (NBS) programs continue to expand due to innovations in both test methods and treatment options. Since the introduction of the T-cell receptor excision circle (TREC) assay 15 years ago, many countries have adopted screening for severe combined immunodeficiency (SCID) in their NBS program. SCID became the first inborn error of immunity (IEI) in population-based screening and at the same time the TREC assay became the first high-throughput DNA-based test in NBS laboratories. In addition to SCID, there are many other IEI that could benefit from early diagnosis and intervention by preventing severe infections, immune dysregulation, and autoimmunity, if a suitable NBS test was available. Advances in technologies such as KREC analysis, epigenetic immune cell counting, protein profiling, and genomic techniques such as next-generation sequencing (NGS) and whole-genome sequencing (WGS) could allow early detection of various IEI shortly after birth. In the next years, the role of these technical advances as well as ethical, social, and legal implications, logistics and cost will have to be carefully examined before different IEI can be considered as suitable candidates for inclusion in NBS programs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA