Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Eur J Orthop Surg Traumatol ; 34(2): 869-877, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37750976

RESUMO

INTRODUCTION: This study aims to identify radiographic and clinical risk factors of perioperative periprosthetic femur fracture associated with the direct anterior approach (DAA) using a metaphyseal fit and fill stem. We hypothesize stem malalignment with this femoral implant places increased stress on the medial calcar region, which leads to an increased risk of periprosthetic fracture. METHODS: We compared patients with periprosthetic femur fractures following DAA total hip arthroplasty (THA) utilizing the Echo Bi-Metric Microplasty Stem (Zimmer Biomet, Warsaw, IN) to a cohort of patients who did not sustain a periprosthetic fracture from five orthopedic surgeons over four years. Postoperative radiographs were evaluated for stem alignment, neck cut level, Dorr classification, and the presence of radiographic pannus. Univariate and logistic regression analyses were performed. Demographic and categorical variables were also analyzed. RESULTS: Fourteen hips sustained femur fractures, including nine Vancouver B2 and five AG fractures. Valgus stem malalignment, proud stems, extended offset, and patients with enlarged radiographic pannus reached statistical significance for increased fracture risk. Low femoral neck cut showed a trend toward statistical significance. CONCLUSION: Patients undergoing DAA THA using a metaphyseal fit and fill stem may be at increased risk of perioperative periprosthetic fracture when the femoral stem sits proudly in valgus malalignment with extended offset and when an enlarged pannus is seen radiographically. This study identifies a specific pattern in the Vancouver B2 fracture cohort with regard to injury mechanism, time of injury, and fracture pattern, which may be attributed to coronal malalignment of the implant.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Fraturas Periprotéticas/diagnóstico por imagem , Fraturas Periprotéticas/etiologia , Prótese de Quadril/efeitos adversos , Estudos Retrospectivos , Fêmur/cirurgia , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Reoperação/efeitos adversos , Hipertrofia/etiologia
2.
Mod Rheumatol ; 26(5): 757-60, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26708312

RESUMO

OBJECTIVES: The purpose of this retrospective study is to report the incidence of osteolysis and evaluate the significance of screening computed tomography (CT) compared to plain radiography in detecting osteolysis after total hip arthroplasty with metal-on-highly cross-linked polyethylene bearings. METHODS: We retrospectively reviewed 264 primary cementless total hip arthroplasties of 211 patients, 24 males, 187 females, who received postoperative screening CT scan in addition to radiography at postoperative 7-10 years (average 8.2 years). First-generation highly cross-linked polyethylene was used in all cases. RESULTS: On the plain radiographs, no acetabular osteolysis (0%) and two cases of femoral osteolysis (0.8%) were found in the follow-up period. No osteolysis was newly found by screening CT scan. CONCLUSIONS: Very low incidence of osteolysis after total hip arthroplasty with highly cross-linked polyethylene at postoperative 7-10 years was confirmed, and routine screening CT scan for detecting osteolysis in this setting was not supported from this study.


Assuntos
Acetábulo/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril/efeitos adversos , Osteólise/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Adulto Jovem
3.
J Orthop Surg Res ; 17(1): 223, 2022 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-35399097

RESUMO

BACKGROUND: To compare the degree of stem subsidence between two different femoral component designs and to determine the risk factors associated with stem subsidence after cementless total hip arthroplasty (THA) in Dorr type C femurs. METHODS: We retrospectively reviewed 104 consecutive hips in 100 patients with Dorr type C proximal femoral morphology who underwent primary cementless THA using a fit-and-fill stem or a tapered wedge femoral stem at our institution between January 2012 and June 2021. A fit-and-fill stem was used in 55 hips and a tapered wedge stem was used in 49 hips. Radiologically, the distance between the apex of the major trochanter and the stem shoulder were measured at three different time points (immediately [0W], one week [1W], and six weeks [6W] after surgery) and the degrees of stem subsidence were assessed by comparing the distance between 0 and 1W, 1W and 6W, and 0W and 6W, respectively. RESULTS: The mean degree of stem subsidence (0W vs. 1W) was 0.24 mm (standard deviation [SD] 0.36) in the fit-and-fill stem group, and 0.23 mm (SD 0.41) in the tapered wedge stem group. There was no significant difference between the two groups (P = 0.4862). However, the mean degrees of subsidence were significantly higher in the fit-and-fill stem group (1W vs. 6W, 0.38 mm [SD 0.68]; 0W vs. 6W, 0.65 mm [SD 0.87]) than in the tapered wedge stem group (1W vs. 6W, 0.16 mm [SD 0.32]; 0W vs. 6W, 0.24 mm [SD 0.38]) (P < 0.05 for both). In addition, the rates of > 3 mm subsidence (in which instability can be observed) were 18.2% (10 of 55 hips) and 2.0% (1 of 49 hips), respectively. There was also a significant difference between the two stems (P = 0.0091). Multivariate analysis demonstrated that fit-and-fill stem was a risk factor for > 3 mm subsidence after THA in Dorr type C femurs (P = 0.0050). CONCLUSION: Our findings suggest that the tapered wedge stem is more suitable for Dorr type C femurs than the fit-and-fill stem to avoid early postoperative subsidence in cementless THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Estudos Retrospectivos
4.
Orthop Traumatol Surg Res ; 102(6): 717-21, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27291079

RESUMO

BACKGROUND: Low polyethylene wear rate and low incidence of osteolysis after total hip arthroplasty using annealed and remelted highly cross-linked polyethylene have been reported. However, there is no previous report that directly compared both types of highly cross-linked polyethylene. We therefore performed a retrospective study on a series of highly cross-linked polyethylene, in order to: (1) compare wear rates and the incidence of osteolysis between annealed and remelted highly cross-linked polyethylene at 7-10 years; (2) identify the frequency of complication related to annealed and remelted highly cross-linked polyethylene. HYPOTHESIS: There is no difference in the linear wear rate and the incidence of osteolysis between the annealed and remelted highly cross-linked polyethylene in total hip arthroplasty. PATIENTS AND METHODS: Two hundred and sixteen cases of cementless total hip arthroplasties with annealed or remelted highly cross-linked polyethylene, which were performed between January 2003 and December 2006 in one institution, were followed for 7-10 years and received computed tomography scan, in addition to radiography at the latest follow-up. Annealed and remelted highly cross-linked polyethylene was used in 91 cases and 125 cases, respectively. A 26-mm cobalt-chromium head was used in all cases. Penetration rates from 1 year to the last evaluation were used to estimate the yearly linear wear rate. Existence of osteolysis was evaluated by plain radiography and computed tomography. RESULTS: There were no significant differences in patients' background between the two groups. The linear wear rate of annealed and remelted group was 0.031±0.022mm/year and 0.032±0.020mm/year, respectively (P=0.91). Two cases of small femoral osteolysis were found in the annealed group. Any complication related to highly cross-linked polyethylene was not found in both groups. DISCUSSION: There was no significant difference in the linear wear rate and the incidence of osteolysis between the annealed and remelted group at postoperative 7 to 10 years. Excellent results of both types of highly cross-linked polyethylene were revealed by this study. LEVEL OF EVIDENCE: Level III retrospective case control study.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Osteólise/etiologia , Polietileno , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Fêmur/diagnóstico por imagem , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Polietileno/efeitos adversos , Falha de Prótese , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA