Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.848
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Cell ; 187(18): 5064-5080.e14, 2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39089254

RESUMO

So far, biocomputation strictly follows traditional design principles of digital electronics, which could reach their limits when assembling gene circuits of higher complexity. Here, by creating genetic variants of tristate buffers instead of using conventional logic gates as basic signal processing units, we introduce a tristate-based logic synthesis (TriLoS) framework for resource-efficient design of multi-layered gene networks capable of performing complex Boolean calculus within single-cell populations. This sets the stage for simple, modular, and low-interference mapping of various arithmetic logics of interest and an effectively enlarged engineering space within single cells. We not only construct computational gene networks running full adder and full subtractor operations at a cellular level but also describe a treatment paradigm building on programmable cell-based therapeutics, allowing for adjustable and disease-specific drug secretion logics in vivo. This work could foster the evolution of modern biocomputers to progress toward unexplored applications in precision medicine.


Assuntos
Redes Reguladoras de Genes , Humanos , Lógica , Biologia Sintética/métodos , Engenharia Genética/métodos , Biologia Computacional/métodos , Animais
2.
Physiol Rev ; 100(4): 1467-1525, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32191560

RESUMO

Impairments of vision and hearing are highly prevalent conditions limiting the quality of life and presenting a major socioeconomic burden. For a long time, retinal and cochlear disorders have remained intractable for causal therapies, with sensory rehabilitation limited to glasses, hearing aids, and electrical cochlear or retinal implants. Recently, the application of gene therapy and optogenetics to eye and ear has generated hope for a fundamental improvement of vision and hearing restoration. To date, one gene therapy for the restoration of vision has been approved, and ongoing clinical trials will broaden its application including gene replacement, genome editing, and regenerative approaches. Moreover, optogenetics, i.e., controlling the activity of cells by light, offers a more general alternative strategy. Over little more than a decade, optogenetic approaches have been developed and applied to better understand the function of biological systems, while protein engineers have identified and designed new opsin variants with desired physiological features. Considering potential clinical applications of optogenetics, the spotlight is on the sensory systems, particularly the eye and ear. Multiple efforts have been undertaken to restore lost or hampered function in the eye and ear. Optogenetic stimulation promises to overcome fundamental shortcomings of electrical stimulation, namely, poor spatial resolution and cellular specificity, and accordingly to deliver more detailed sensory information. This review aims to provide a comprehensive reference on current gene therapeutic and optogenetic research relevant to the restoration of hearing and vision. We will introduce gene-therapeutic approaches and discuss the biotechnological and optoelectronic aspects of optogenetic hearing and vision restoration.


Assuntos
Perda Auditiva/terapia , Transtornos da Visão/terapia , Humanos , Optogenética , Próteses Visuais
3.
Annu Rev Neurosci ; 42: 47-65, 2019 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-30699049

RESUMO

The modern cochlear implant (CI) is the most successful neural prosthesis developed to date. CIs provide hearing to the profoundly hearing impaired and allow the acquisition of spoken language in children born deaf. Results from studies enabled by the CI have provided new insights into (a) minimal representations at the periphery for speech reception, (b) brain mechanisms for decoding speech presented in quiet and in acoustically adverse conditions, (c) the developmental neuroscience of language and hearing, and (d) the mechanisms and time courses of intramodal and cross-modal plasticity. Additionally, the results have underscored the interconnectedness of brain functions and the importance of top-down processes in perception and learning. The findings are described in this review with emphasis on the developing brain and the acquisition of hearing and spoken language.


Assuntos
Percepção Auditiva/fisiologia , Implantes Cocleares , Período Crítico Psicológico , Desenvolvimento da Linguagem , Animais , Transtornos da Percepção Auditiva/etiologia , Encéfalo/crescimento & desenvolvimento , Implante Coclear , Compreensão , Sinais (Psicologia) , Surdez/congênito , Surdez/fisiopatologia , Surdez/psicologia , Surdez/cirurgia , Desenho de Equipamento , Humanos , Transtornos do Desenvolvimento da Linguagem/etiologia , Transtornos do Desenvolvimento da Linguagem/prevenção & controle , Aprendizagem/fisiologia , Plasticidade Neuronal , Estimulação Luminosa
4.
Clin Microbiol Rev ; 37(2): e0010423, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38506553

RESUMO

SUMMARYImplant-associated infections (IAIs) pose serious threats to patients and can be associated with significant morbidity and mortality. These infections may be difficult to diagnose due, in part, to biofilm formation on device surfaces, and because even when microbes are found, their clinical significance may be unclear. Despite recent advances in laboratory testing, IAIs remain a diagnostic challenge. From a therapeutic standpoint, many IAIs currently require device removal and prolonged courses of antimicrobial therapy to effect a cure. Therefore, making an accurate diagnosis, defining both the presence of infection and the involved microorganisms, is paramount. The sensitivity of standard microbial culture for IAI diagnosis varies depending on the type of IAI, the specimen analyzed, and the culture technique(s) used. Although IAI-specific culture-based diagnostics have been described, the challenge of culture-negative IAIs remains. Given this, molecular assays, including both nucleic acid amplification tests and next-generation sequencing-based assays, have been used. In this review, an overview of these challenging infections is presented, as well as an approach to their diagnosis from a microbiologic perspective.


Assuntos
Técnicas Microbiológicas , Infecções Relacionadas à Prótese , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/microbiologia , Técnicas Microbiológicas/métodos , Bactérias/isolamento & purificação , Bactérias/classificação , Bactérias/genética , Laboratórios Clínicos , Técnicas de Diagnóstico Molecular/métodos
5.
J Neurosci ; 44(28)2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38830759

RESUMO

Congenital single-sided deafness (SSD) leads to an aural preference syndrome that is characterized by overrepresentation of the hearing ear in the auditory system. Cochlear implantation (CI) of the deaf ear is an effective treatment for SSD. However, the newly introduced auditory input in congenital SSD often does not reach expectations in late-implanted CI recipients with respect to binaural hearing and speech perception. In a previous study, a reduction of the interaural time difference (ITD) sensitivity has been shown in unilaterally congenitally deaf cats (uCDCs). In the present study, we focused on the interaural level difference (ILD) processing in the primary auditory cortex. The uCDC group was compared with hearing cats (HCs) and bilaterally congenitally deaf cats (CDCs). The ILD representation was reorganized, replacing the preference for the contralateral ear with a preference for the hearing ear, regardless of the cortical hemisphere. In accordance with the previous study, uCDCs were less sensitive to interaural time differences than HCs, resulting in unmodulated ITD responses, thus lacking directional information. Such incongruent ITDs and ILDs cannot be integrated for binaural sound source localization. In normal hearing, the predominant effect of each ear is excitation of the auditory cortex in the contralateral cortical hemisphere and inhibition in the ipsilateral hemisphere. In SSD, however, auditory pathways reorganized such that the hearing ear produced greater excitation in both cortical hemispheres and the deaf ear produced weaker excitation and preserved inhibition in both cortical hemispheres.


Assuntos
Córtex Auditivo , Implante Coclear , Sinais (Psicologia) , Perda Auditiva Unilateral , Localização de Som , Gatos , Animais , Localização de Som/fisiologia , Perda Auditiva Unilateral/fisiopatologia , Implante Coclear/métodos , Córtex Auditivo/fisiopatologia , Feminino , Masculino , Estimulação Acústica/métodos , Lateralidade Funcional/fisiologia , Surdez/fisiopatologia , Surdez/congênito , Surdez/cirurgia
6.
Med Res Rev ; 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39287199

RESUMO

Nanocomposite materials are emerging as key players in addressing critical challenges in healthcare, energy storage, and environmental remediation. These innovative systems hold great promise in engineering effective solutions for complex problems. Nanocomposites have demonstrated various advantages such as simplicity, versatility, lightweight, and potential cost-effectiveness. By reinforcing synthetic and natural polymers with nanomaterials, a range of nanocomposites have exhibited unique physicochemical properties, biocompatibility, and biodegradability. Current research on nanocomposites has demonstrated promising clinical and translational applications. Over the past decade, the production of nanocomposites has emerged as a critical nano-structuring methodology due to their adaptability and controllable surface structure. This comprehensive review article systematically addresses two principal domains. A comprehensive survey of metallic and nonmetallic nanomaterials (nanofillers), elucidating their efficacy as reinforcing agents in polymeric matrices. Emphasis is placed on the methodical design and engineering principles governing the development of functional nanocomposites. Additionally, the review provides an exhaustive examination of recent noteworthy advancements in industrial, environmental, biomedical, and clinical applications within the realms of nanocomposite materials. Finally, the review concludes by highlighting the ongoing challenges facing nanocomposites in a wide range of applications.

7.
Eur J Neurosci ; 59(10): 2596-2615, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38441248

RESUMO

Auditory deprivation following congenital/pre-lingual deafness (C/PD) can drastically affect brain development and its functional organisation. This systematic review intends to extend current knowledge of the impact of C/PD and deafness duration on brain resting-state networks (RSNs), review changes in RSNs and spoken language outcomes post-cochlear implant (CI) and draw conclusions for future research. The systematic literature search followed the PRISMA guideline. Two independent reviewers searched four electronic databases using combined keywords: 'auditory deprivation', 'congenital/prelingual deafness', 'resting-state functional connectivity' (RSFC), 'resting-state fMRI' and 'cochlear implant'. Seventeen studies (16 cross-sectional and one longitudinal) met the inclusion criteria. Using the Crowe Critical Appraisal Tool, the publications' quality was rated between 65.0% and 92.5% (mean: 84.10%), ≥80% in 13 out of 17 studies. A few studies were deficient in sampling and/or ethical considerations. According to the findings, early auditory deprivation results in enhanced RSFC between the auditory network and brain networks involved in non-verbal communication, and high levels of spontaneous neural activity in the auditory cortex before CI are evidence of occupied auditory cortical areas with other sensory modalities (cross-modal plasticity) and sub-optimal CI outcomes. Overall, current evidence supports the idea that moreover intramodal and cross-modal plasticity, the entire brain adaptation following auditory deprivation contributes to spoken language development and compensatory behaviours.


Assuntos
Implante Coclear , Surdez , Humanos , Surdez/fisiopatologia , Implante Coclear/métodos , Encéfalo/fisiopatologia , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Rede Nervosa/fisiopatologia , Rede Nervosa/diagnóstico por imagem , Imageamento por Ressonância Magnética , Córtex Auditivo/fisiopatologia , Córtex Auditivo/diagnóstico por imagem , Implantes Cocleares , Resultado do Tratamento
8.
Small ; : e2404351, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39161205

RESUMO

Titanium and titanium alloys remain the gold standard for dental and orthopedic implants. These materials are heavily used because of their bioinert nature, robust mechanical properties, and seamless integration with bone. However, implant-associated infections (IAIs) remain one of the leading causes of implant failure. Eradicating an IAI can be difficult since bacteria can form biofilms on the medical implant, protecting the bacterial cells against systemic antibiotics and the host's immune system. If the infection is not treated promptly and aggressively, device failure is inevitable, leading to costly multi-step revision surgeries. To circumvent this dire situation, scientists and engineers continue to develop novel strategies to protect the surface of medical implants from bacteria. In this review, details on emerging strategies to prevent infection in titanium implants are reported. These strategies include anti-adhesion properties provided by polymers, superhydrophobic, superhydrophilic, and liquid-infused surface coatings, as well as strategies and coatings employed to lyse the bacteria. Additionally, commercially available technologies and those under preclinical trials are examined while discussing current and future trends.

9.
Small ; : e2403298, 2024 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-39428890

RESUMO

Surgical site infection and insufficient osseointegration are notable risks factors associated with oral implant surgery. In this study, the development of a polarized calcium titanate (CT-P) coating for titanium surfaces is proposed as a solution to these problems. The coating generated electrical stimulation (ES) can inhibit pro-inflammatory M1-type macrophage polarization and promote anti-inflammatory M2-type macrophage polarization, resulting in favorable bone immunomodulation. The ES generated by the coating can match the physiological electrical potential that will change during bone repair, thereby promoting osseointegration in vivo. In addition, the system can also achieve on-demand antibacterial activity, mainly depending on the CT-P coating responding to ultrasound (US) irradiation to produce reactive oxygen species (ROS) and remove Staphylococcus aureus (S. aureus) on the surface of the implant. In conclusion, this work provides valuable insights for the development and clinical application of highly efficient electroactive coatings, as well as novel solutions for the selective treatment of bacterial infections in the surgical area.

10.
Small ; 20(28): e2307742, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38326101

RESUMO

Biodegradable medical implants promise to benefit patients by eliminating risks and discomfort associated with permanent implantation or surgical removal. The time until full resorption is largely determined by the implant's material composition, geometric design, and surface properties. Implants with a fixed residence time, however, cannot account for the needs of individual patients, thereby imposing limits on personalization. Here, an active Fe-based implant system is reported whose biodegradation is controlled remotely and in situ. This is achieved by incorporating a galvanic cell within the implant. An external and wireless signal is used to activate the on-board electronic circuit that controls the corrosion current between the implant body and an integrated counter electrode. This configuration leads to the accelerated degradation of the implant and allows to harvest electrochemical energy that is naturally released by corrosion. In this study, the electrochemical properties of the Fe-30Mn-1C/Pt galvanic cell model system is first investigated and high-resolution X-ray microcomputed tomography is used to evaluate the galvanic degradation of stent structures. Subsequently, a centimeter-sized active implant prototype is assembled with conventional electronic components and the remotely controlled corrosion is tested in vitro. Furthermore, strategies toward the miniaturization and full biodegradability of this system are presented.


Assuntos
Metais , Corrosão , Metais/química , Microtomografia por Raio-X , Próteses e Implantes , Eletroquímica , Implantes Absorvíveis , Técnicas Eletroquímicas/métodos
11.
J Transl Med ; 22(1): 120, 2024 01 31.
Artigo em Inglês | MEDLINE | ID: mdl-38297308

RESUMO

BACKGROUND: One of the main factors for the osseointegration of dental implants is the development of an adequate soft tissue barrier, mainly composed by collagen, which protects the implant from bacterial development. The structural features of the peri-implant collagen are influenced by the implant components and, in particular, by the type of the surface. In the clinical practice, healing abutments are characterized by smooth surfaces, named machined. Recently, a new laser technique, Synthegra, has been developed to obtain a topography-controlled surface with micrometric regular pores that seems reducing the risk of peri-implantitis. Based on this background, this study aims investigating the structural organization and spatial distribution of collagen surrounding healing abutments characterized by laser-treated and machined surfaces. METHODS: Gingiva portions surrounding custom-made healing abutments (HA), characterized by alternated laser-treated and machined surfaces, were collected and analyzed by combining Fourier Transform InfraRed Imaging (FTIRI) spectroscopy, a non-invasive and high-resolution bidimensional analytical technique, with histological and multivariate analyses. RESULTS: Masson's trichrome staining, specific for collagen, highlighted a massive presence of collagen in all the analyzed samples, evidencing a surface-related spatial distribution. The nature of collagen, investigated by the FTIRI spectroscopy, appeared more abundant close to the laser-treated surface, with a perpendicular disposition of the bundles respect to the HA; conversely, a parallel distribution was observed around the machined surface. A different secondary structure was also found, with a higher amount of triple helices and a lower quantity of random coils in collagen close to the laser treated surfaces. CONCLUSIONS: FTIRI spectroscopy demonstrates that the use of a laser treated transmucosal surface can improve the morphological organization of the peri-implant collagen, which presents a distribution more similar to that of natural teeth. TRIAL REGISTRATION: This trial is registered with ClinicalTrials.gov Identifier: (Registration Number: NCT05754970). Registered 06/03/2023, retrospectively registered, https://clinicaltrials.gov/show/NCT05754970 .


Assuntos
Implantes Dentários , Colágeno , Gengiva/patologia , Lasers , Osseointegração , Propriedades de Superfície , Humanos
12.
Magn Reson Med ; 92(6): 2571-2579, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38987979

RESUMO

PURPOSE: Fluid-sensitive turbo spin echo (TSE) MRI with short-TI inversion-recovery preparation for fat suppression (STIR) plays a critical role in the diagnostics of the musculoskeletal system (e.g., close to metal implants). Potential advantages of 3D acquisitions, however, are difficult to exploit due to long acquisition times. Shortening the TR incurs a signal loss, and a driven-equilibrium (DE) extension reduces fluid signal even further. METHODS: The phase of the flip-back pulse was changed by 180° relative to the conventional implementation (i.e., 90° along the positive x-axis (90°x) instead of -90°x). After signal modeling and numerical simulations, the modification was implemented in STIR-TSE sequences and tested on a clinical 3T system. Imaging was performed in the lumbar spine, and long-TR images without DE were acquired as reference. CSF SNR and fluid-muscle contrast were measured and compared between the sequences. Imaging was repeated in a metal implant phantom. RESULTS: A shortening of TR by 43%-57% reduced the CSF SNR by 39%-59%. A conventional DE module further reduced SNR to 26%-40%, whereas the modified DE recovered SNR to 59%-108% compared with the long-TR acquisitions. Fluid-tissue contrast was increased by about 340% with the modified DE module compared with the conventional extension. Similar results were obtained in implant measurements. CONCLUSIONS: The proposed DE element for TSE-STIR sequences has the potential to accelerate the acquisition of fluid-sensitive images. DE-STIR may work most efficiently for 3D acquisitions, in which no temporo-spatial interleaving of inversion and imaging pulses is possible.


Assuntos
Estudos de Viabilidade , Imageamento por Ressonância Magnética , Imagens de Fantasmas , Razão Sinal-Ruído , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Masculino , Vértebras Lombares/diagnóstico por imagem , Feminino , Adulto , Tecido Adiposo/diagnóstico por imagem , Simulação por Computador , Aumento da Imagem/métodos
13.
J Cardiovasc Electrophysiol ; 35(4): 747-761, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38361241

RESUMO

INTRODUCTION: The implantation of a cardiac implantable electronic device (CIED) can have esthetic and psychological consequences on patients. We explore a heart team model for care coordination and discuss esthetic approaches for improved cosmetic outcomes in patients undergoing (CIED)-related procedures or de novo implantation. METHODS: Patients undergoing CIED surgery for approved indications between June 2015 and June 2022 were identified. Patients were included when surgical care was provided by a collaborative relationship between the primary electrophysiologist and the plastic surgeon. Patient demographics, details of the surgical procedure, information on breast implants, complications, and outcomes related to cosmesis were recorded. RESULTS: Twenty-two female patients were included in this study. The mean age was 50.2 ± 18.2 years. The mean follow-up duration was 2.2 ± 5.5 months. The top two indications for the procedure included CIED generator change (n = 9, 41%) and implantable cardioverter-defibrillator (ICD) implantation (n = 7, 32%). The most common reasons for involving plastic surgery in the procedure included surgery near breast implants (n = 10, 45%) and device displacement or discomfort (n = 8, 36%). CIED pocket position was prepectoral in 10 cases (45%), subpectoral in 11 patients (50%), and intramuscular in one patient (4.5%). The majority of the patients (20, 91%) had cosmetically acceptable results postprocedure. One patient (4.5%) had breast asymmetry on the CIED side, and another continued to have skin erosion over the CIED and leads. CONCLUSION: A heart team approach incorporating the expertize of cardiac electrophysiology and plastic surgery is essential for providing optimal care for patients with breast implants and patients requesting esthetic appeal.


Assuntos
Implantes de Mama , Procedimentos Cirúrgicos Cardíacos , Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Implantes de Mama/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Estudos Retrospectivos
14.
Strahlenther Onkol ; 2024 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-39207463

RESUMO

BACKGROUND: Chordomas and chondrosarcomas of the skull base are rare, slowly growing malignant bone neoplasms. Despite their radioresistant properties, proton therapy has been successfully used as an adjunct to resection or as a definitive treatment. Herewith, we present our experience with robustly optimized intensity-modulated proton therapy (IMPT) and related toxicities in skull base chordoma and chondrosarcoma patients treated at HollandPTC, Delft, the Netherlands. METHODS: Clinical data, treatment plans, and acute toxicities of patients treated between July 2019 and August 2021 were reviewed. CT and 3.0T MRI scans for treatment planning were performed in supine position in a thermoplastic mold. In total, 21 dose optimization and 28 dose evaluation scenarios were simulated. Acute toxicity was scored weekly before and during the treatment according to the CTCAE v4.0. Median follow-up was 35 months (range 12-36 months). RESULTS: Overall, 9 chordoma and 3 chondrosarcoma patients with 1-3 resections prior to IMPT were included; 4 patients had titanium implants. Brainstem core and surface and spinal cord core and surface were used for nominal plan robust optimization in 11, 10, 8, and 7 patients, respectively. Middle ear inflammation, dry mouth, radiation dermatitis, taste disorder, and/or alopecia of grades 1-3 were noted at the end of treatment among 6 patients without similar complaints at inclusion; symptoms disappeared 3 months following the treatment. CONCLUSION: Robustly optimized IMPT is clinically feasible as a postoperative treatment for skull base chordoma and chondrosarcoma patients. We observed acceptable early toxicities (grade 1-3) that disappeared within the first 3 months after irradiation.

15.
J Magn Reson Imaging ; 59(5): 1514-1522, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37767980

RESUMO

The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have "MR Conditional" (i.e., an item with demonstrated safety in the MR environment within defined conditions) labeling at 1.5 and/or 3 T only. This presents challenges for a facility that has a scanner operating at a field strength below 1.5 T when encountering a patient with an implant, because scanning the patient is considered "off-label." In this case, the supervising physician is responsible for deciding whether to scan the patient based on the risks associated with the implant and the benefit of magnetic resonance imaging (MRI). For a passive implant, the MRI safety-related concerns are static magnetic field interactions (i.e., force and torque) and radiofrequency (RF) field-induced heating. The worldwide utilization of scanners operating below 1.5 T combined with the increasing incidence of patients with implants that need MRI creates circumstances that include patients potentially being subjected to unsafe imaging conditions or being denied access to MRI because physicians often lack the knowledge to perform an assessment of risk vs. benefit. Thus, physicians must have a complete understanding of the MRI-related safety issues that impact passive implants when managing patients with these products on scanners operating below 1.5 T. This monograph provides an overview of the various clinical MR systems operating below 1.5 T and discusses the MRI-related factors that influence safety for passive implants. Suggestions are provided for the management of patients with passive implants labeled MR Conditional at 1.5 and/or 3 T, referred to scanners operating below 1.5 T. The purpose of this information is to empower supervising physicians with the essential knowledge to perform MRI exams confidently and safely in patients with passive implants. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Assuntos
Campos Magnéticos , Próteses e Implantes , Humanos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
16.
Muscle Nerve ; 69(2): 134-147, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38126120

RESUMO

After an amputation, advanced prosthetic limbs can be used to interface with the nervous system and restore motor function. Despite numerous breakthroughs in the field, many of the recent research advancements have not been widely integrated into clinical practice. This review highlights recent innovations in neuromuscular implants-specifically those that interface with skeletal muscle-which could improve the clinical translation of prosthetic technologies. Skeletal muscle provides a physiologic gateway to harness and amplify signals from the nervous system. Recent surgical advancements in muscle reinnervation surgeries leverage the "bio-amplification" capabilities of muscle, enabling more intuitive control over a greater number of degrees of freedom in prosthetic limbs than previously achieved. We anticipate that state-of-the-art implantable neuromuscular interfaces that integrate well with skeletal muscle and novel surgical interventions will provide a long-term solution for controlling advanced prostheses. Flexible electrodes are expected to play a crucial role in reducing foreign body responses and improving the longevity of the interface. Additionally, innovations in device miniaturization and ongoing exploration of shape memory polymers could simplify surgical procedures for implanting such interfaces. Once implanted, wireless strategies for powering and transferring data from the interface can eliminate bulky external wires, reduce infection risk, and enhance day-to-day usability. By outlining the current limitations of neuromuscular interfaces along with potential future directions, this review aims to guide continued research efforts and future collaborations between engineers and specialists in the field of neuromuscular and musculoskeletal medicine.


Assuntos
Membros Artificiais , Músculo Esquelético , Eletrodos
17.
World J Urol ; 42(1): 35, 2024 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217727

RESUMO

PURPOSE: Past decade has seen a renewed interest in minimally invasive surgical techniques (MISTs) for management of enlarged prostate. This narrative review aims to explore newer MIST for benign prostatic hyperplasia (BPH) which are not yet integrated into established societal guidelines. METHODS: We conducted a literature search across PubMed, Google Scholar, and FDA ClinicalTrials.gov databases on June 1st, 2023, to identify studies published within the past decade exploring various MISTs for BPH. Additionally, we gathered insights from abstracts presented in meetings of professional associations and corporate websites. We broadly classified these procedures into three distinct categories: energy-based, balloon dilation, and implant/stent treatments. We collected detail information about the device, procedure details, its inclusion and exclusion criteria, and outcome. RESULTS: Our review reveals that newer energy-based MISTs include Transperineal Laser Ablation, Transurethral Ultrasound Ablation, and High-Intensity Focused Ultrasound. In the sphere of balloon dilation, Transurethral Columnar Balloon Dilation and the Optilume BPH Catheter System were gaining momentum. The noteworthy implants/stents that are on horizon include Butterfly Prostatic Retraction Device, Urocross Expander System, Zenflow Spring System, and ProVee Urethral Expander System. CONCLUSION: The exploration of various MISTs reflects ongoing efforts to enhance patient care and address limitations of existing treatments. This review provides a bird-eye view and valuable insights for urologists and researchers seeking to navigate the dynamic landscape of MISTs in the quest for effective and minimally invasive solutions for enlarged prostates.


Assuntos
Hiperplasia Prostática , Ressecção Transuretral da Próstata , Masculino , Humanos , Hiperplasia Prostática/cirurgia , Próstata/cirurgia , Ressecção Transuretral da Próstata/métodos , Prostatectomia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos , Stents
18.
Eur Radiol ; 34(3): 1556-1566, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37658140

RESUMO

OBJECTIVE: Bioabsorbable magnesium-based alloy screws release gas upon resorption. The resulting findings in the adjacent soft tissues and joints may mimic infection. The aim of the study was to evaluate the ultrasound (US) findings in soft tissues and joints during screw resorption. METHODS: Prospectively acquired US studies from pediatric patients treated with magnesium screws were evaluated for screw head visibility, posterior acoustic shadowing, twinkling artifact, foreign body granuloma, gas (soft tissue, intra-articular), alterations of the skin and subcutaneous fat, perifascial fluid, localized fluid collections, hypervascularization, and joint effusion. RESULTS: Sixty-six US studies of 28 pediatric patients (nfemale = 9, nmale = 19) were included. The mean age of the patients at the time of surgery was 10.84 years; the mean time between surgery and ultrasound was 128.3 days (range = 6-468 days). The screw head and posterior acoustic shadowing were visible in 100% of the studies, twinkling artifact in 6.1%, foreign body granuloma in 92.4%, gas locules in soft tissue in 100% and intra-articular in 18.2%, hyperechogenicity of the subcutaneous fat in 90.9%, cobblestoning of the subcutaneous fat in 24.2%, loss of normal differentiation between the epidermis/dermis and the subcutaneous fat in 57.6%, localized fluid collection in 9.9%, perifascial fluid in 12.1%, hypervascularization in 27.3%, and joint effusion in 18.2%. CONCLUSION: US findings in pediatric patients treated with magnesium screws strongly resemble infection, but are normal findings in the setting of screw resorption. CLINICAL RELEVANCE STATEMENT: Bioabsorbable magnesium-based alloy screws release gas during resorption. The resulting US findings in the adjacent soft tissues and joints in pediatric patients may mimic infection, but are normal findings. KEY POINTS: • Bioabsorbable magnesium-based alloy screws release gas upon resorption. • The resulting ultrasound findings in children's soft tissues and joints closely resemble those of soft tissue infection or osteosynthesis-associated infection. • Be familiar with these ultrasound findings in order to avoid inadvertently misdiagnosing a soft tissue infection or osteosynthesis-associated infection.


Assuntos
Fraturas Ósseas , Granuloma de Corpo Estranho , Infecções dos Tecidos Moles , Humanos , Masculino , Feminino , Criança , Magnésio , Implantes Absorvíveis , Granuloma de Corpo Estranho/etiologia , Infecções dos Tecidos Moles/etiologia , Fraturas Ósseas/etiologia , Ligas , Fixação Interna de Fraturas/métodos , Parafusos Ósseos/efeitos adversos
19.
AIDS Behav ; 2024 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-39465464

RESUMO

Children living with HIV (CLWH) face unique challenges with adherence to antiretroviral therapy. In South Africa, just over a third of children receiving antiretroviral therapy are virally suppressed. Long-acting, subcutaneous implants may improve outcomes in CLWH compared to current daily oral dosing regimens. Qualitative in-depth interviews and focus group discussions (FGD) were conducted with 50 caregivers of CLHW in Johannesburg, South Africa. Interviews and FGDs were audio-recorded and transcribed. Data were coded and analyzed using Dedoose v9 software and a thematic approach. Caregivers had generally positive impressions of the pediatric HIV treatment implant. They emphasized the advantages of a long-acting and discreet treatment option for CLWH. Cited advantages were perceived to have widespread impact on CLWH, their caregivers, and other social dynamics. Caregivers raised some concerns or uncertainties about the potential efficacy, side effects and safety of the implant. Future clinical testing and outreach efforts may address such concerns and mitigate potential misinformation about implants. This study indicates the need to develop long-acting, discreet, safe, and efficacious HIV treatment options for young children.

20.
Periodontol 2000 ; 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38305506

RESUMO

Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants. It is characterized by inflammation in the peri-implant mucosa and progressive loss of supporting bone. Over the last 30 years, peri-implantitis has become a major disease burden in dentistry. An understanding of the diagnosis, etiology and pathogenesis, epidemiology, and treatment of peri-implantitis must be a central component in undergraduate and postgraduate training programs in dentistry. In view of the strong role of European research in periodontology and implant dentistry, the focus of this review was to address peri-implantitis from a European perspective. One component of the work was to summarize new and reliable data on patients with dental implants to underpin the relevance of peri-implantitis from a population perspective. The nature of the peri-implantitis lesion was evaluated through results presented in preclinical models and evaluations of human biopsy material together with an appraisal of the microbiological characteristics. An overview of strategies and outcomes presented in clinical studies on nonsurgical and surgical treatment of peri-implantitis is discussed with a particular focus on end points of therapy and recommendations presented in the S3 level Clinical Practice Guideline for the prevention and treatment of peri-implant diseases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA