Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Thromb Haemost ; 17(12): 2081-2088, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31529590

RESUMO

BACKGROUND: JNJ-9375 is an antibody against exosite 1 on thrombin, inhibits substrate binding but not catalytic activity. OBJECTIVE: To examine the possibility that JNJ-9375 attenuates thrombosis without affecting hemostasis, we compared the efficacy and safety of JNJ-9375 and apixaban. METHODS: In this double-blind, double-dummy phase 2 trial, 308 patients undergoing knee arthroplasty were randomized to receive either a single postoperative intravenous infusion of JNJ-9375 in doses ranging from 0.3 to 1.8 mg/kg or apixaban (2.5 mg twice daily). The primary efficacy endpoint was the incidence of venous thromboembolism (assessed by mandatory unilateral venography or confirmed symptomatic events). The primary safety outcome was the composite of major, clinically relevant nonmajor, and minimal bleeding. Thrombin times were measured to assess JNJ-9375 activity. RESULTS: A total of 239 of the 308 patients (77.6%) were included in the modified intention-to-treat analysis. Of these, 238 had evaluable venograms and one had symptomatic deep-vein thrombosis confirmed by ultrasound. Despite dose-dependent thrombin time prolongation, the primary efficacy outcome occurred in 59 of 190 patients (31.1%) in the combined JNJ-9375 groups as compared with 6 of 49 patients (12.2%) given apixaban (odds ratio 3.2; two-sided 80% confidence interval 1.8-5.8; P = .011). The excess events with JNJ-9375 compared with apixaban were consistent across all JNJ-9375 dosing cohorts and there was no evidence of improved efficacy with higher JNJ-9375 doses. There were no major bleeds with JNJ-9375 or apixaban, and rates of any bleeding were similar with the highest and lowest JNJ-9375 doses. CONCLUSIONS: JNJ-9375 was safe but less effective than apixaban. This may reflect weak thrombin inhibition or inability of JNJ-9375 to attenuate the growth of thrombi that formed before drug administration.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Anticoagulantes/administração & dosagem , Artroplastia do Joelho/efeitos adversos , Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/administração & dosagem , Pirazóis/administração & dosagem , Piridonas/administração & dosagem , Trombina/antagonistas & inibidores , Tromboembolia Venosa/prevenção & controle , Trombose Venosa/prevenção & controle , Idoso , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticoagulantes/efeitos adversos , Método Duplo-Cego , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Trombina/imunologia , Trombina/metabolismo , Tempo de Trombina , Fatores de Tempo , Resultado do Tratamento , Tromboembolia Venosa/sangue , Tromboembolia Venosa/diagnóstico por imagem , Tromboembolia Venosa/etiologia , Trombose Venosa/sangue , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/etiologia
2.
Cardiovasc Res ; 115(3): 669-677, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30184110

RESUMO

AIMS: JNJ-64179375 (hereafter JNJ-9375) is a first-in-class, highly specific, large molecule, exosite 1 thrombin inhibitor. In preclinical studies, JNJ-9375 demonstrated robust antithrombotic protection with a wider therapeutic index when compared to apixaban. The purpose of the present study was to examine for the first time the antiplatelet, anticoagulant and antithrombotic effects of JNJ-9375 in a translational model of ex vivo human thrombosis. METHODS AND RESULTS: Fifteen healthy volunteers participated in a double-blind randomized crossover study of JNJ-9375 (2.5, 25, and 250 µg/mL), bivalirudin (6 µg/mL; positive control), and matched placebo. Coagulation, platelet activation, and thrombus formation were determined using coagulation assays, flow cytometry, and an ex vivo perfusion chamber, respectively.JNJ-9375 caused concentration-dependent prolongation of all measures of blood coagulation (prothrombin time, activated partial thromboplastin time, and thrombin time; P < 0.001 for all) and agonist selective inhibition of thrombin (0.1 U/mL) stimulated platelet p-selectin expression (P < 0.001) and platelet-monocyte aggregates (P = 0.002). Compared to placebo, JNJ-9375 (250 µg/mL) reduced mean total thrombus area by 41.1% (95% confidence intervals 22.3 to 55.3%; P < 0.001) at low shear and 32.3% (4.9 to 51.8%; P = 0.025) at high shear. Under both shear conditions, there was a dose-dependent decrease in fibrin-rich thrombus (P < 0.001 for both) but not platelet-rich thrombus (P = ns for both). CONCLUSION: Exosite 1 inhibition with JNJ-9375 caused prolongation of blood coagulation, selective inhibition of thrombin-mediated platelet activation, and reductions in ex vivo thrombosis driven by a decrease in fibrin-rich thrombus formation. JNJ-9375 represents a novel class of anticoagulant with potential therapeutic applications.


Assuntos
Antitrombinas/administração & dosagem , Coagulação Sanguínea/efeitos dos fármacos , Plaquetas/efeitos dos fármacos , Ativação Plaquetária/efeitos dos fármacos , Trombose/prevenção & controle , Adulto , Antitrombinas/efeitos adversos , Biomarcadores/sangue , Testes de Coagulação Sanguínea , Plaquetas/metabolismo , Estudos Cross-Over , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Fibrina/metabolismo , Voluntários Saudáveis , Hirudinas/administração & dosagem , Humanos , Masculino , Selectina-P/sangue , Fragmentos de Peptídeos/administração & dosagem , Proteínas Recombinantes/administração & dosagem , Escócia , Trombose/sangue , Trombose/diagnóstico , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA