Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
NMR Biomed ; 37(2): e5054, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37794648

RESUMO

The aim of the current study was to compare the performance of fully automated software with human expert interpretation of single-voxel proton magnetic resonance spectroscopy (1H-MRS) spectra in the assessment of breast lesions. Breast magnetic resonance imaging (MRI) (including contrast-enhanced T1-weighted, T2-weighted, and diffusion-weighted imaging) and 1H-MRS images of 74 consecutive patients were acquired on a 3-T positron emission tomography-MRI scanner then automatically imported into and analyzed by SpecTec-ULR 1.1 software (LifeTec Solutions GmbH). All ensuing 117 spectra were additionally independently analyzed and interpreted by two blinded radiologists. Histopathology of at least 24 months of imaging follow-up served as the reference standard. Nonparametric Spearman's correlation coefficients for all measured parameters (signal-to-noise ratio [SNR] and integral of total choline [tCho]), Passing and Bablok regression, and receiver operating characteristic analysis, were calculated to assess test diagnostic performance, as well as to compare automated with manual reading. Based on 117 spectra of 74 patients, the area under the curve for tCho SNR and integrals ranged from 0.768 to 0.814 and from 0.721 to 0.784 to distinguish benign from malignant tissue, respectively. Neither method displayed significant differences between measurements (automated vs. human expert readers, p > 0.05), in line with the results from the univariate Spearman's rank correlation coefficients, as well as the Passing and Bablok regression analysis. It was concluded that this pilot study demonstrates that 1H-MRS data from breast MRI can be automatically exported and interpreted by SpecTec-ULR 1.1 software. The diagnostic performance of this software was not inferior to human expert readers.


Assuntos
Neoplasias da Mama , Colina , Humanos , Feminino , Espectroscopia de Prótons por Ressonância Magnética , Colina/análise , Projetos Piloto , Sensibilidade e Especificidade , Mama/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
2.
Skeletal Radiol ; 51(8): 1585-1594, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35088162

RESUMO

OBJECTIVE: To qualitatively evaluate the utility of zero echo-time (ZTE) MRI sequences in identifying osseous findings and to compare ZTE with optimized spoiled gradient echo (SPGR) sequences in detecting knee osseous abnormalities. MATERIALS AND METHODS: ZTE and standard knee MRI sequences were acquired at 3T in 100 consecutive patients. Three radiologists rated confidence in evaluating osseous abnormalities and image quality on a 5-grade Likert scale in ZTE compared to standard sequences. In a subset of knees (n = 57) SPGR sequences were also obtained, and diagnostic confidence in identifying osseous structures was assessed, comparing ZTE and SPGR sequences. Statistical significance of using ZTE over SPGR was characterized with a paired t-test. RESULTS: Image quality of the ZTE sequences was rated high by all reviewers with 278 out of 299 (100 studies, 3 radiologists) scores ≥ 4 on the Likert scale. Diagnostic confidence in using ZTE sequences was rated "very high confidence" in 97%, 85%, 71%, and 73% of the cases for osteophytosis, subchondral cysts, fractures, and soft tissue calcifications/ossifications, respectively. In 74% of cases with osseous findings, reviewer scores indicated confidence levels (score ≥ 3) that ZTE sequences improved diagnostic certainty over standard sequences. The diagnostic confidence in using ZTE over SPGR sequences for osseous structures as well as abnormalities was favorable and statistically significant (p < 0.01). CONCLUSION: Incorporating ZTE sequences in the standard knee MRI protocol was technically feasible and improved diagnostic confidence for osseous findings in relation to standard MR sequences. In comparison to SPGR sequences, ZTE improved assessment of osseous abnormalities.


Assuntos
Osso e Ossos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 29(3): 1435-1443, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30120494

RESUMO

OBJECTIVES: To prospectively determine the feasibility of preoperative supine breast MRI in breast cancer patients scheduled for oncoplastic breast-conserving surgery. METHODS: In addition to a diagnostic prone breast MRI, a supplementary supine MRI was performed with the patient in the surgical position including skin markers. Tumours' locations were ink-marked on the skin according to findings obtained from supine MRI. Changes in tumours' largest diameter and locations between prone and supine MRI were measured and compared to histology. Nipple-to-tumour and tumour-to-chest wall distances were also measured. Tumours and suspicious areas were surgically removed according to skin ink-markings. The differences between MRI measurements with reference to histopathology were evaluated with the paired-sample t test. RESULTS: Fourteen consecutive patients, 15 breasts and 27 lesions were analysed. Compared to histology, prone MRI overestimated tumour size by 47.1% (p = 0.01) and supine MRI by 14.5% (p = 0.259). In supine MRI, lesions' mean diameters and areas were smaller compared to prone MRI (- 20.9%, p = 0.009 and - 38.3%, p = 0.016, respectively). This difference in diameter was more pronounced in non-mass lesions (- 31.2%, p = 0.031) compared to mass lesions (- 9.2%, p = 0.009). Tumours' mean distance from chest wall diminished by 69.4% (p < 0.001) and from nipple by 18.2% (p < 0.001). Free microscopic margins were achieved in first operation in all patients. CONCLUSIONS: Supine MRI in the surgical position is feasible and useful in the precise localisation of prone MRI-detected lesions and provides a helpful tool to implement in surgery. Supine MRI more accurately determines tumours' size and location and might have an important role to diminish overestimations. KEY POINTS: • Breath-hold supine breast MRI is feasible using commercially available coils and sequences. • Size and area of lesions on MRI were consistently smaller when measured from the supine position as compared to the prone position. • Supine breast MRI is useful in the precise preoperative localisation of prone MRI-detected lesions. •.


Assuntos
Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Mastectomia Segmentar/métodos , Decúbito Dorsal , Adulto , Idoso , Neoplasias da Mama/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
MAGMA ; 32(5): 539-547, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31144164

RESUMO

OBJECTIVE: Several studies have demonstrated that anisotropic phantoms can be utilized for diffusion magnetic resonance imaging. The purpose of our study was to examine whether wood is suitable as an anisotropic phantom material from the viewpoints of affordability and availability. In the current study, wood was used for restricted diffusion, and fibers were used for hindered diffusion. MATERIALS AND METHODS: Wood and fiber phantoms were made. Diffusion kurtosis images were acquired with three magnetic resonance scanners. Fractional anisotropy, radial diffusivity, axial diffusivity, radial kurtosis and axial kurtosis values were measured. The wood phantom was imaged, and its durability was confirmed. The phantoms were imaged in varying orientations within the magnetic field. The wood was observed using an optical microscope. RESULTS: Ten kinds of wood and the fiber had a diffusion metrics. The wood diffusion metrics suggested low variation over a period of 9 months. Changing the orientation of the phantoms within the magnetic field resulted in changes in diffusion metrics. Observation of wood vessels and fibers was conducted. DISCUSSION: Wood and fibers have anisotropy and are promising as phantom materials. The development of anisotropic phantoms that anyone can use is useful for diffusion magnetic resonance imaging research and clinical applications.


Assuntos
Anisotropia , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/instrumentação , Imagem de Tensor de Difusão/instrumentação , Imagens de Fantasmas , Artefatos , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Humanos , Teste de Materiais , Madeira
5.
Hum Brain Mapp ; 39(10): 4150-4161, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29952102

RESUMO

Postmortem studies of Parkinson's disease (PD) suggest that Lewy body pathology accumulates in a predictable topographical sequence, beginning in the olfactory bulb, followed by caudal brainstem, substantia nigra, limbic cortex, and neocortex. Diffusion-weighted imaging (DWI) is sensitive, if not specific, to early disease-related white matter (WM) change in a variety of traumatic and degenerative brain diseases. Although numerous cross-sectional studies have reported DWI differences in cerebral WM in PD, only a few longitudinal studies have investigated whether DWI change exceeds that of normal aging or coincides with regional Lewy body accumulation. This study mapped regional differences in the rate of DWI-based microstructural change between 29 PD patients and 43 age-matched controls over 18 months. Iterative within- and between-subject tensor-based registration was completed on motion- and eddy current-corrected DWI images, then baseline versus follow-up difference maps of fractional anisotropy, mean, radial, and axial diffusivity were analyzed in the Biological Parametric Mapping toolbox for MATLAB. This analysis showed that PD patients had a greater decline in WM integrity in the rostral brainstem, caudal subcortical WM, and cerebellar peduncles, compared with controls. In addition, patients with unilateral clinical signs at baseline experienced a greater rate of WM change over the 18-month study than patients with bilateral signs. These findings suggest that rate of WM microstructural change in PD exceeds that of normal aging and is maximal during early stage disease. In addition, the neuroanatomic locations (rostral brainstem and subcortical WM) of accelerated WM change fit with current theories of topographic disease progression.


Assuntos
Envelhecimento/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Progressão da Doença , Doença de Parkinson/patologia , Substância Branca/patologia , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico por imagem , Índice de Gravidade de Doença , Substância Branca/diagnóstico por imagem
6.
Eur Radiol ; 28(5): 2236-2245, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29168004

RESUMO

PURPOSE: To compare inter-reader concordance and accuracy of qualitative diffusion-weighted (DW) PIRADSv2.0 score with those of quantitative DW-MRI for the diagnosis of peripheral zone prostate cancer. MATERIALS AND METHODS: Two radiologists independently assigned a DW-MRI-PIRADS score to 92 PZ-foci, in 74 patients (64.3±5.6 years old; median PSA level: 8 ng/ml, normal DRE in 70 men). A standardised ADCmean and nine ADC-derived parameters were measured, including ADCratios with the whole-prostate (WP-ADCratio) or the mirror-PZ (mirror-ADCratio) as reference areas. Surgical histology and MRI-TRUS fusion-biopsy were the reference for tumours and benign foci, respectively. Inter-reader agreement was assessed by the Cohen-kappa-coefficient and the intraclass correlation coefficient (ICC). Univariate-multivariate regressions determined the most predictive factor for cancer. RESULTS: Fifty lesions were malignant. Inter-reader concordance was fair for qualitative assessment, but excellent for quantitative assessment for all quantitative variables. At univariate analysis, ADCmean, WP-ADCratio and WL-ADCmean performed equally, but significantly better than the mirror-ADCratio (p<0.001). At multivariate analysis, the only independent variable significantly associated with malignancy was the whole-prostate-ADCratio. At a cut-off value of 0.68, sensitivity was 94-90 % and specificity was 60-38 % for readers 1 and 2, respectively. CONCLUSION: The whole-prostate-ADCratio improved the qualitative inter-reader concordance and characterisation of focal PZ-lesions. KEY POINTS: • Inter-reader concordance of DW PI-RADSv2.0 score for PZ lesions was only fair. • Using a standardised ADCmean measurement and derived DW-quantitative parameters, concordance was excellent. • The whole-prostate ADCratio performed significantly better than the mirror-ADCratio for cancer detection. • At a cut-off of 0.68, sensitivity values of WP-ADCratio were 94-90 %. • The whole-prostate ADCratio may circumvent variations of ADC metrics across centres.


Assuntos
Imagem de Difusão por Ressonância Magnética/normas , Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos
7.
Eur Radiol ; 28(1): 11-16, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28687911

RESUMO

OBJECTIVES: To compare the incremental diagnostic value of targeted biopsy using real-time multiparametric magnetic resonance imaging and transrectal ultrasound (mpMRI-TRUS) fusion to conventional 14-cores biopsy. PATIENTS AND METHODS: Uni-institutional, institutional review board (IRB) approved prospective blinded study comparing TRUS-guided random and targeted biopsy using mpMRI-TRUS fusion, in 100 consecutive men. We included men with clinical-laboratorial suspicious for prostate cancer and Likert score ≥ 3 mp-MRI. Patients previously diagnosed with prostate cancer were excluded. All patients were submitted to 14-cores TRUS-guided biopsy (mpMRI data operator-blinded), followed by targeted biopsy using mpMRI-TRUS fusion. RESULTS: There was an overall increase in cancer detection rate, from 56% with random technique to 62% combining targeted biopsy using mpMRI-TRUS fusion; incremental diagnosis was even more relevant for clinically significant lesions (Gleason ≥ 7), diagnosing 10% more clinically significant lesions with fusion biopsy technique. Diagnosis upgrade occurred in 5 patients that would have negative results in random biopsies and had clinically significant tumours with the combined technique, and in 5 patients who had the diagnosis of significant tumours after fusion biopsy and clinically insignificant tumours in random biopsies(p=0.0010). CONCLUSIONS: Targeted biopsy using mpMRI-TRUS fusion has incremental diagnostic value in comparison to conventional random biopsy, better detecting clinically significant prostate cancers. KEY POINTS: • mpMRI-TRUS targeted biopsy increases overall cancer detection rate, but not statistically significant. • mpMRI-TRUS targeted biopsy actually improves the diagnosis of clinically significant PCa. • There was no evidence to acquire the mpMRI-TRUS fusion cores alone.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Endossonografia/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Neoplasias da Próstata/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Neuroimage ; 150: 88-98, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28179166

RESUMO

The human insula is implicated in numerous functions. More and more neuroimaging studies focus on this region, however no atlas offers a complete subdivision of the insula in a reference space. The aims of this study were to define a protocol to subdivide insula, to create probability maps in the MNI152 stereotaxic space, and to provide normative reference volume measurements for these subdivisions. Six regions were manually delineated bilaterally on 3D T1 MR images of 30 healthy subjects: the three short gyri, the anterior inferior cortex, and the two long gyri. The volume of the insular grey matter was 7.7 ± 0.9cm3 in native space and 9.9 ± 0.6cm3 in MNI152 space. These volumes expressed as a percentage of the ipsilateral grey matter volume were minimally larger in women (2.7±0.2%) than in men (2.6±0.2%). After spatial normalization, a stereotactic probabilistic atlas of each subregion was produced, as well as a maximum-probability atlas taking into account surrounding structures. Automatically labelling insular subregions via a multi-atlas propagation and label fusion strategy (MAPER) in a leave-one-out experiment showed high spatial overlaps of such automatically defined insular subregions with the manually derived ones (mean Jaccard index 0.65, corresponding to a mean Dice index of 0.79), with an average mean volume error of 2.6%. Probabilistic and maximum probability atlases and the original delineations are available on the web under free academic licences.


Assuntos
Anatomia Artística , Atlas como Assunto , Córtex Cerebral/anatomia & histologia , Adulto , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neuroimagem , Adulto Jovem
9.
Eur Radiol ; 27(12): 5146-5157, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28631080

RESUMO

OBJECTIVE: To compare cardiac left ventricular (LV) parameters in simultaneously acquired hybrid fluorine-18-fluorodeoxyglucose ([18F] FDG) positron emission tomography/magnetic resonance imaging (PET/MRI) in patients with residual tracer activity of upstream PET/CT. METHODS: Twenty-nine patients (23 men, age 58±17 years) underwent cardiac PET/MRI either directly after a non-cardiac PET/CT with homogenous cardiac [18F] FDG uptake (n=20) or for viability assessment (n=9). Gated cardiac [18F] FDG PET and cine MR sequences were acquired simultaneously and evaluated blinded to the cross-imaging results. Image quality (IQ), end-diastolic (LVEDV), end-systolic volume (LVESV), ejection fraction (LVEF) and myocardial mass (LVMM) were measured. Pearson correlation and intraclass correlation coefficient (ICC), regression and a Bland-Altman analysis were assessed. RESULTS: Except LVMM, volumetric and functional LV parameters demonstrated high correlations (LVESV: r=0.97, LVEDV: r=0.95, LVEF: r=0.91, LVMM: r=0.87, each p<0.05), but wide limits of agreement (LOA) for LVEDV (-25.3-82.5ml); LVESV (-33.1-72.7ml); LVEF (-18.9-14.8%) and LVMM (-78.2-43.2g). Intra- and interobserver reliability were very high (ICC≥0.95) for all parameters, except for MR-LVEF (ICC=0.87). PET-IQ (0-3) was high (mean: 2.2±0.9) with significant influence on LVMM calculations only. CONCLUSION: In simultaneously acquired cardiac PET/MRI data, LVEDV, LVESV and LVEF show good agreement. However, the agreement seems to be limited if cardiac PET/MRI follows PET/CT and only the residual activity is used. KEY POINTS: • [ 18 F] FDG PET-MRI is feasible with residual [ 18 F] FDG activity in patients with homogenous cardiac uptake. • Cardiac volumes and function assessed by PET/MRI show good agreement. • LVEDV and LVESV are underestimated; PET overestimates LVMM and LVEF. • Cardiac PET and MRI data correlate better when acquired simultaneously than sequentially. • PET and MRI should not assess LV parameters interchangeably.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons/métodos , Volume Sistólico , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
10.
J Magn Reson Imaging ; 44(6): 1565-1571, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27185307

RESUMO

PURPOSE: To assess the feasibility of applying diffusion kurtosis imaging (DKI) to common odontogenic lesions and to compare its diagnostic ability versus that of the apparent diffusion coefficient (ADC) for differentiating keratocystic odontogenic tumors (KCOTs) from odontogenic cysts. MATERIALS AND METHODS: Altogether, 35 odontogenic lesions were studied: 24 odontogenic cysts, six KCOTs, and five ameloblastomas. The diffusion coefficient (D) and excessive kurtosis (K) were obtained from diffusion-weighted images at b-values of 0, 500, 1000, and 1500 s/mm2 on 3T magnetic resonance imaging (MRI). The combination of D and K values showing the maximum density of the probable density function was estimated. The ADC was obtained (0 and 1000 s/mm2 ). Values for odontogenic cysts, KCOTs, and ameloblastomas were compared. Multivariate logistic regression modeling was performed to assess the combination of D and K model versus ADC for differentiating KCOTs from odontogenic cysts. RESULTS: The mean D and ADC were significantly higher for ameloblastomas than for odontogenic cysts or KCOTs (P < 0.05). The mean K was significantly lower for ameloblastomas than for odontogenic cysts or KCOTs (P < 0.05). The mean values of all parameters for odontogenic cysts and KCOTs showed no significant differences (P = 0.369 for ADC, 0.133 for D, and 0.874 for K). The accuracy of the combination of D and K model (76.7%) was superior to that of ADC (66.7%). CONCLUSION: Use of DKI may be feasible for common odontogenic lesions. A combination of DKI parameters can be expected to increase the accuracy of its diagnostic ability compared with ADC. J. Magn. Reson. Imaging 2016;44:1565-1571.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Cistos Odontogênicos/diagnóstico por imagem , Tumores Odontogênicos/diagnóstico , Adolescente , Adulto , Idoso , Criança , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cistos Odontogênicos/patologia , Tumores Odontogênicos/patologia , Radiografia Dentária/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
11.
Hum Brain Mapp ; 35(10): 5141-52, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24819224

RESUMO

Adult ADHD has been linked to impaired motor response inhibition and reduced associated activation in the right inferior frontal cortex (IFC). However, it is unclear whether abnormal inferior frontal activation in adult ADHD is specifically related to a response inhibition deficit or reflects a more general deficit in attentional processing. Using functional magnetic resonance imaging, we tested a group of 19 ADHD patients with no comorbidities and a group of 19 healthy control volunteers on a modified go/no-go task that has been shown previously to distinguish between cortical responses related to response inhibition and attentional shifting. Relative to the healthy controls, ADHD patients showed increased commission errors and reduced activation in inferior frontal cortex during response inhibition. Crucially, this reduced activation was observed when controlling for attentional processing, suggesting that hypoactivation in right IFC in ADHD is specifically related to impaired response inhibition. The results are consistent with the notion of a selective neurocognitive deficit in response inhibition in adult ADHD associated with abnormal functional activation in the prefrontal cortex, whilst ruling out likely group differences in attentional orienting, arousal and motivation.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/patologia , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Lobo Frontal/fisiopatologia , Lateralidade Funcional/fisiologia , Inibição Psicológica , Adulto , Análise de Variância , Mapeamento Encefálico , Tomada de Decisões , Imagem Ecoplanar , Feminino , Lobo Frontal/irrigação sanguínea , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Oxigênio/sangue , Fatores Sexuais , Adulto Jovem
12.
Magn Reson Med Sci ; 23(3): 252-267, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38897936

RESUMO

MRI has progressed significantly with the introduction of advanced computational methods and novel imaging techniques, but their wider adoption hinges on their reproducibility. This concise review synthesizes reproducible research insights from recent MRI articles to examine the current state of reproducibility in neuroimaging, highlighting key trends and challenges. It also provides a custom generative pretrained transformer (GPT) model, designed specifically for aiding in an automated analysis and synthesis of information pertaining to the reproducibility insights associated with the articles at the core of this review.


Assuntos
Imageamento por Ressonância Magnética , Neuroimagem , Humanos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
13.
Radiol Bras ; 57: e20230125, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38993969

RESUMO

Objective: To evaluate the diagnostic accuracy of multi-echo Dixon magnetic resonance imaging (MRI) in hepatic fat quantification, in comparison with that of magnetic resonance spectroscopy (MRS), on 3.0-T MRI. Materials and Methods: Fifty-five adults with no known liver disease underwent MRI in a 3.0-T scanner for determination of the hepatic fat fraction, with two techniques: multi-echo Dixon, in a manually drawn region of interest (ROI) and in the entire liver parenchyma (automated segmentation); and MRS. The diagnostic accuracy and cutoff value for multi-echo Dixon were determined, with MRS being used as the reference standard. Results: The mean fat fraction obtained by multi-echo Dixon in the manually drawn ROI and in the entire liver was 5.2 ± 5.8% and 6.6 ± 5.2%, respectively, whereas the mean hepatic fat fraction obtained by MRS was 5.7 ± 6.4%. A very strong positive correlation and good agreement were observed between MRS and multi-echo Dixon, for the ROI (r = 0.988, r2 = 0.978, p < 0.001) and for the entire liver parenchyma (r = 0.960, r2 = 0.922, p < 0.001). A moderate positive correlation was observed between the hepatic fat fraction and body mass index of the participants, regardless of the fat estimation technique employed. Conclusion: For hepatic fat quantification, multi-echo Dixon MRI demonstrated a very strong positive correlation and good agreement with MRS (often considered the gold-standard noninvasive technique). Because multi-echo Dixon MRI is more readily available than is MRS, it can be used as a rapid tool for hepatic fat quantification, especially when the hepatic fat distribution is not homogeneous.


Objetivo: Avaliar a acurácia diagnóstica da técnica multieco Dixon na quantificação da gordura hepática em comparação com a espectroscopia por ressonância magnética (ERM), em exames de RM 3.0-T. Materiais e Métodos: Cinquenta e cinco participantes adultos sem doença hepática conhecida foram submetidos a RM 3.0-T para determinação da fração de gordura hepática, usando duas técnicas: multieco Dixon (em ROI desenhada manualmente e em segmentação automatizada para todo o parênquima hepático) e ERM. A precisão diagnóstica e o valor de corte para multieco Dixon foram determinados usando a ERM como padrão de referência. Resultados: A fração de gordura média usando multieco Dixon na ROI desenhada manualmente e na segmentação automatizada do fígado inteiro foi 5,2 ± 5,8% e 6,6 ± 5,2%, respectivamente. A fração de gordura hepática média usando ERM foi 5,7 ± 6,4%. Correlação positiva muito alta e forte concordância foram observadas entre ERM e multieco Dixon, tanto para ROI (r = 0,988, r2 = 0,978, p < 0,001) quanto para todo o parênquima hepático (r = 0,960, r2 = 0,922, p < 0,001). Correlação positiva moderada foi observada entre a fração de gordura hepática e o índice de massa corpórea dos participantes usando ambas as técnicas de estimativa de gordura. Conclusão: Multieco Dixon demonstrou correlação positiva muito alta e concordância com a ERM (muitas vezes considerada padrão de referência não invasivo) para quantificação de gordura hepática. Uma vez que o multieco Dixon está mais prontamente disponível do que a ERM, pode ser usado como uma ferramenta rápida para a quantificação da gordura hepática, especialmente na distribuição não homogênea da gordura.

14.
Radiol Bras ; 57: e20230111en, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38993971

RESUMO

Objective: To evaluate the indications for and results of magnetic resonance imaging (MRI) examinations for breast cancer screening at a cancer center in Brazil. Materials and Methods: This was a retrospective observational study, based on electronic medical records, of patients undergoing MRI for breast cancer screening at a cancer center in Brazil. Results: We included 597 patients between 19 and 82 years of age. The main indications for MRI screening were a personal history of breast cancer, in 354 patients (59.3%), a family history of breast cancer, in 102 (17.1%), and a confirmed genetic mutation, in 67 (11.2%). The MRI result was classified, in accordance with the categories defined in the Breast Imaging Reporting and Data System, as benign (category 1 or 2), in 425 patients (71.2%), probably benign (category 3), in 143 (24.0%), or suspicious (category 4 or 5), in 29 (4.9%). On MRI, 11 malignant tumors were identified, all of which were invasive carcinomas. Among those 11 carcinomas, six (54.5%) were categorized as minimal cancers (< 1 cm), and the axillary lymph nodes were negative in 10 (90.9%). The cancer detection rate was 18.4/1,000 examinations, and the positive predictive value for suspicious lesions submitted to biopsy was 37.9%. Conclusion: In our sample, the main indication for breast MRI screening was a personal history of breast cancer. The results indicate that MRI is a highly accurate method for the early detection of breast neoplasms in this population.


Objetivo: Avaliar as indicações e resultados de exames de ressonância magnética (RM) para rastreamento de câncer de mama em um centro oncológico no Brasil. Materiais e Métodos: Estudo observacional, realizado mediante análise retrospectiva de pacientes submetidos a RM das mamas para rastreamento de câncer de mama, por meio de revisão do prontuário eletrônico em um centro oncológico. Resultados: Foram incluídas 597 pacientes com idade variando de 19 a 82 anos. As principais indicações para rastreamento foram história pessoal de câncer de mama em 354 (59,3%) pacientes, história familiar em 102 (17,1%) e mutação genética confirmada em 67 (11,2%). O resultado da RM foi benigno (BI-RADS 1 ou 2) em 425 (71,2%) pacientes, provavelmente benigno (BI-RADS 3) em 143 (24,0%) e suspeito (BI-RADS 4 ou 5) em 29 (4,9%). Foram identificados 11 tumores malignos na RM, todos carcinomas invasivos, porcentagem de cânceres "mínimos" (< 1 cm) de 54,5% e porcentagem de axila negativa de 90,9%. A taxa de detecção de câncer na RM foi 18,4/1000 exames e o valor preditivo positivo para as lesões suspeitas submetidas a biópsia foi 37,9%. Conclusão: A principal indicação para RM de rastreamento na nossa população foi história pessoal de câncer de mama. Os resultados mostraram que a RM constitui um método com alta acurácia para detecção precoce de neoplasias da mama nessa população.

15.
Magn Reson Imaging ; 113: 110216, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39067654

RESUMO

PURPOSE: This study assessed the clinical classification performance of an R2*-based MRI technique for LIC quantification relative to FerriScan, with intra-patient FerriScan LIC uncertainty taken into account. The variabilities of R2* and FerriScan LIC were also assessed. MATERIALS AND METHODS: This was an ethics approved retrospective study, performed on patients undergoing chelation treatment for iron overload. 126 patients (69 women, 57 men), with an age of 42 +/- 16 years (range 19-86 years) were included. FerriScan and R2* MRI at 1.5 T were performed as part of a routine liver iron assessment protocol. For R2* MRI, a commercially available pulse sequence and reconstruction implementation was used, together with a previously derived calibration curve to convert R2* to LIC. Clinical classifications arising from R2*-derived LIC estimates were compared to those based on FerriScan. The accuracy and precision of the R2* technique was calculated. The variabilities of FerriScan- and R2*-derived estimates of LIC were compared with a Wilcoxon Signed Rank test. Significance was set at the 95% confidence level. RESULTS: The precision of R2* ranged from 0.59 to 0.92, with an overall accuracy of 72%. When intra-patient FerriScan LIC uncertainty was considered, precision and accuracy increased to >94% and 97% respectively. The R2*-LIC variability (=17%) was significantly lower than the FerriScan-LIC variability (34%) at the 95% confidence level (p < 10-3). CONCLUSION: MRI R2*-based LIC estimates provided a similar clinical classification as FerriScan. The intra-patient uncertainty of R2*-based LIC estimates was significantly lower than FerriScan.


Assuntos
Sobrecarga de Ferro , Ferro , Fígado , Imageamento por Ressonância Magnética , Humanos , Adulto , Masculino , Feminino , Sobrecarga de Ferro/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Imageamento por Ressonância Magnética/métodos , Idoso de 80 Anos ou mais , Fígado/diagnóstico por imagem , Fígado/metabolismo , Ferro/metabolismo , Reprodutibilidade dos Testes , Adulto Jovem , Estudos Retrospectivos , Sensibilidade e Especificidade , Nanopartículas de Magnetita , Meios de Contraste
16.
Radiol Bras ; 56(2): 95-101, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37168045

RESUMO

Crohn's disease is an inflammatory bowel disease that can affect any segment of the gastrointestinal tract. It has a variable clinical course, with alternating periods of disease activity and remission. Because the incidence and prevalence of Crohn's disease have been increasing, evaluation by imaging methods has become more important. The most widely used methods are computed tomography enterography, magnetic resonance enterography (as an elective examination), and contrast-enhanced computed tomography (in the context of emergency). Computed tomography enterography and magnetic resonance enterography are useful for diagnosis, follow-up, evaluation of complications, and prognosis. Both can be used in order to evaluate the small bowel loops and the associated mesenteric findings, as well as to evaluate other abdominal organs. They both also can detect signs of disease activity, fibrosis, penetrating disease, and complications. The interpretation of such changes is essential to the multidisciplinary approach, as is the standardization of the nomenclature employed in the reports. In this paper, we review and illustrate the imaging findings of Crohn's disease, using the standardized nomenclature proposed in the multidisciplinary consensus statement issued by the Society of Abdominal Radiology, the Society of Pediatric Radiology, and the American Gastroenterology Association, with recommendations for descriptions, interpretations, and impressions related to those findings.


Doença de Crohn é uma doença inflamatória intestinal que pode acometer qualquer segmento do trato gastrointestinal, com curso clínico variado, alternando períodos de atividade de doença e remissão. Sua incidência e prevalência vêm aumentando, tornando a avaliação por métodos de imagem mais importante. Os métodos mais utilizados são enterotomografia computadorizada, enterorressonância magnética eletivamente e tomografia computadorizada com contraste no contexto da emergência. A enterotomografia computadorizada e a enterorressonância magnética são úteis para diagnóstico, seguimento, avaliação de complicações e para prognóstico. Avaliam as alças intestinais delgadas e os achados mesentéricos associados, além dos demais órgãos abdominais. Detectam sinais de atividade de doença, sinais de cronicidade e doença penetrante e complicações, importantes para a escolha do melhor tratamento. A interpretação dessas alterações é fundamental para que a equipe multidisciplinar trabalhe conjuntamente com compreensão da linguagem utilizada nos relatórios. Neste artigo, apresentamos uma revisão dos achados de imagem da doença de Crohn e ilustramos os possíveis achados dessa doença utilizando a nomenclatura padronizada proposta no consenso multidisciplinar composto pelas Sociedade de Radiologia Abdominal, Sociedade de Radiologia Pediátrica e a Associação Americana de Gastroenterologia, com recomendações de descrição, interpretação dos achados e recomendações de impressão.

17.
Radiol Bras ; 56(2): 67-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37168041

RESUMO

Objective: The perfusion profile of vestibular schwannomas (VSs) and the factors that influence it have yet to be determined. Materials and Methods: Twenty patients with sporadic VS were analyzed by calculating parameters related to the extravascular extracellular space (EES)-the volume transfer constant between a vessel and the EES (Ktrans); the EES volume per unit of tissue volume (Ve); and the rate transfer constant between EES and blood plasma (Kep)-as well as the relative cerebral blood volume (rCBV), and by correlating those parameters with the size of the tumor and its structure (solid, cystic, or heterogeneous). Results: Although Ktrans, Ve, and Kep were measurable in all tumors, rCBV was measurable only in large tumors. We detected a positive correlation between Ktrans and rCBV (r = 0.62, p = 0.031), a negative correlation between Ve and Kep (r = -0.51, p = 0.021), and a positive correlation between Ktrans and Ve only in solid VSs (r = 0.64, p = 0.048). Comparing the means for small and large VSs, we found that the former showed lower Ktrans (0.13 vs. 0.029, p < 0.001), higher Kep (0.68 vs. 0.46, p = 0.037), and lower Ve (0.45 vs. 0.83, p < 0.001). The mean Ktrans was lower in the cystic portions of cystic VSs than in their solid portions (0.14 vs. 0.32, p < 0.001), as was the mean Ve (0.37 vs. 0.78, p < 0.001). There were positive correlations between the solid and cystic portions for Ktrans (r = 0.71, p = 0.048) and Kep (r = 0.74, p = 0.037). Conclusion: In VS, tumor size appears to be consistently associated with perfusion values. In cystic VS, the cystic portions seem to have lower Ktrans and Ve than do the solid portions.


Objetivo: O perfil de perfusão do schwannoma vestibular (SV) não tem sido estudado, nem os fatores que o influenciam. Materiais e Métodos: Vinte pacientes com SV esporádico foram analisados usando Ktrans, Ve, Kep e rCBV e correlacionados com tamanho e estádio cístico. Resultados: Ktrans, Ve e Kep foram medidos em todos os casos. rCBV só foi possível em tumores grandes. Ktrans e rCBV estavam correlacionados positivamente (r = 0,62, p = 0, 0 31 ) . Ve e Kep estavam negativamente correlacionados (r = ­0,51, p = 0,021). Ktrans estava correlacionado positivamente com Ve em SVs sólidos (r = 0,64, p = 0,048). Em SVs pequenos, Ktrans foi menor (0,13 vs 0,029, p < 0,001), Kep foi maior (0,68 vs 0,46, p = 0,037) e Ve foi menor (0,45 vs 0,83, p < 0,001) que nos SVs grandes. Ktrans e Ve foram menores dentro dos cistos que nas porções solidas dos SVs císticos (0,14 vs 0,32, p < 0,001; 0,37 vs 0,78, p < 0.001, respectivamente). Foi encontrada correlação positiva em Ktrans (r = 0,71, p = 0,048) e Kep (r = 0,74, p = 0,037) entre as áreas sólidas e císticas. Conclusão: Nos SVs, o tamanho está consistentemente associado com os valores da perfusão. Nos SVs císticos, as porções císticas parecem ter valores menores de Ktrans e Ve do que nas porções sólidas.

18.
Radiol Bras ; 56(4): 187-194, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37829590

RESUMO

Objective: To assess the reliability of phase-sensitive inversion recovery (PSIR) magnetic resonance imaging (MRI) and its accuracy for determining the topography of demyelinating cortical lesions in patients with multiple sclerosis (MS). Materials and Methods: This was a cross-sectional study conducted at a tertiary referral center for MS and other demyelinating disorders. We assessed the agreement among three raters for the detection and topographic classification of cortical lesions on fluid-attenuated inversion recovery (FLAIR) and PSIR sequences in patients with MS. Results: We recruited 71 patients with MS. The PSIR sequences detected 50% more lesions than did the FLAIR sequences. For detecting cortical lesions, the level of interrater agreement was satisfactory, with a mean free-response kappa (κFR) coefficient of 0.60, whereas the mean κFR for the topographic reclassification of the lesions was 0.57. On PSIR sequences, the raters reclassified 366 lesions (20% of the lesions detected on FLAIR sequences), with excellent interrater agreement. There was a significant correlation between the total number of lesions detected on PSIR sequences and the Expanded Disability Status Scale score (ρ = 0.35; p < 0.001). Conclusion: It seems that PSIR sequences perform better than do FLAIR sequences, with clinically satisfactory interrater agreement, for the detection and topographic classification of cortical lesions. In our sample of patients with MS, the PSIR MRI findings were significantly associated with the disability status, which could influence decisions regarding the treatment of such patients.


Objetivo: Avaliar a confiabilidade da sequência PSIR e sua precisão no diagnóstico topográfico de lesões corticais desmielinizantes em pacientes com esclerose múltipla (EM). Materiais e Métodos: Estudo transversal realizado em centro de referência terciário para EM e distúrbios desmielinizantes. Avaliamos a concordância entre três avaliadores na identificação e classificação topográfica de lesões corticais na ressonância magnética de pacientes com EM, utilizando as sequências FLAIR e PSIR. Resultados: Foram incluídos 71 pacientes com EM. Em PSIR detectou-se 1,5× mais lesões do que em FLAIR, com concordância satisfatória entre examinadores na identificação de lesões corticais, com coeficiente kappa de resposta livre (κFR) = 0,60, e na reclassificação topográfica das lesões, com κFR médio = 0,57. Os avaliadores reclassificaram 366 lesões em PSIR (20% das lesões detectadas em FLAIR), com excelente concordância. Houve correlação significativa do total de lesões detectadas em PSIR e o escore da escala de incapacidade EDSS (ρ = 0,35; p < 0,001). Conclusão: PSIR mostrou-se superior na detecção de lesões corticais e na classificação topográfica destas em comparação ao FLAIR, com concordâncias entre examinadores clinicamente satisfatórias. A associação significativa entre o número de lesões corticais em PSIR e o grau de incapacidade dos pacientes pode influenciar em decisões terapêuticas.

19.
Health Econ Rev ; 12(1): 21, 2022 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-35303183

RESUMO

BACKGROUND: To evaluate the potential benefits of the Magnetic Resonance-guided high intensity Focused Ultrasound (MRgFUS) introduction in the clinical practice, for the treatment of uterine fibroids, in comparison with the standard "conservative" procedures, devoted to women who wish to preserve their uterus or enhance fertility: myomectomy and uterine artery embolization (UAE). METHODS: A Health Technology Assessment was conducted, assuming the payer's perspective (Italian National Healthcare Service). The nine EUnetHTA Core Model dimensions were deeply investigated, by means of i) a literature review; ii) the implementation of health economics tools (useful for uterine fibroids patients' clinical pathway economic evaluation, and budget impact analysis), to define MRgFUS economic and organizational sustainability, and iii) administration of specific questionnaires filled by uterine fibroids' experts, to gather their perceptions on the three possible conservative approaches (MRgFUS, UAE and myomectomy). RESULTS: Literature revealed that MRgFUS would generate several benefits, from a safety and an efficacy profile, with significant improvement in symptoms relief. Advantages emerged concerning the patients' perspective, thus leading to a decrease both in the length of hospital stay (p-value< 0.001), and in patients' productivity loss (p-value = 0.024). From an economic point of view, the Italian NHS would present an economic saving of - 6.42%. A positive organizational and equity impact emerged regarding the capability to treat a larger number of women, thus performing, on average, 131.852 additional DRGs. CONCLUSIONS: Results suggest that MRgFUS could be considered an advantageous technological alternative to adopt within the target population affected by uterine fibroids, demonstrating its economic and organisational feasibility and sustainability, with consequent social benefits.

20.
Radiol Bras ; 55(4): 216-224, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35983340

RESUMO

Objective: To promote advanced research using magnetic resonance imaging (MRI) in the diagnosis of and screening for osteoporosis by looking for correlations among the T-scores measured by dual-energy X-ray absorptiometry (DEXA), the apparent diffusion coefficient (ADC) values on diffusion-weighted imaging (DWI), and the T1-weighted signal intensity values. Materials and Methods: This was a prospective study of postmenopausal women with no contraindications to MRI and no history of cancer who underwent DEXA within 30 days before or after the MRI examination. A 3.0-T scanner was used in order to acquire sagittal sequences targeting the lumbar spine. Results: Thirteen women underwent DEXA and MRI. In two cases, the MRI was discontinued early. Therefore, the final sample comprised 11 patients. The ADC values and T1-weighted signal intensity were found to be higher in patients with osteoporosis. However, among the patients > 60 years of age with osteoporosis, ADC values were lower and T1-weighted signal intensity was even higher. Conclusion: It is unlikely that MRI will soon replace DEXA for the diagnostic workup of osteoporosis. Although DWI and ADC mapping are useful for understanding the pathophysiology of osteoporosis, we believe that T1-weighted sequences are more sensitive than is DWI as a means of performing a qualitative analysis of vertebral alterations.


Objetivo: Promover pesquisas avançadas usando ressonância magnética (RM) no diagnóstico e rastreamento de osteoporose, procurando correlações entre os escores T medidos por absorciometria de raios-X de dupla energia (DEXA), valores de coeficiente de difusão aparente (ADC) na difusão e valores de intensidade de sinal ponderado em T1. Materiais e Métodos: Estudo prospectivo de mulheres na pós-menopausa sem contraindicações para RM e sem histórico de câncer que foram submetidas a DEXA 30 dias antes ou após o exame de RM. Um scanner 3.0-T foi utilizado para adquirir sequências sagitais direcionadas à coluna lombar. Resultados: Treze mulheres foram submetidas a DEXA e RM. Em dois casos, a RM foi interrompida precocemente. Portanto, a amostra final foi composta por 11 pacientes. Os valores de ADC e intensidade de sinal ponderado em T1 foram mais elevados nas pacientes com osteoporose. No entanto, no subgrupo de pacientes > 60 anos de idade com osteoporose, os valores de ADC foram menores e a intensidade do sinal ponderado em T1 foi ainda maior. Conclusão: É improvável que a RM substitua DEXA para a investigação diagnóstica da osteoporose no futuro próximo. Embora a difusão e o mapeamento ADC sejam úteis para a compreensão da fisiopatologia da osteoporose, acreditamos que as sequências ponderadas em T1 são mais sensíveis do que a difusão como meio de realizar uma análise qualitativa das alterações vertebrais.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA