Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Sep Sci ; 47(3): e2300696, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38356232

RESUMO

Although filtration is one of the most common steps in sample preparation for chemical analysis, filter membrane materials can leach contaminants and/or retain some analytes in the filtered solutions. In multiclass, multiresidue analysis of veterinary drugs, it is challenging to find one type of filter membrane that does not retain at least some of the analytes before injection in ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). In this study, different filter membranes were tested for use in UHPLC-MS/MS analysis of 183 diverse drugs in bovine muscle, kidney, and liver tissues. Membranes evaluated consisted of polytetrafluoroethylene (PTFE), polyvinylidene difluoride (PVDF), polyethersulfone, nylon, and regenerated cellulose. Drug classes represented among the analytes included ß-agonists, ß-lactams, anthelmintics, macrolides, tetracyclines, sulfonamides, tranquilizers, (fluoro)quinolones, anti-inflammatories, nitroimidazoles, coccidiostats, phenicols, and others. Although the presence of a matrix helped reduce the binding of analytes on surface active sites, all of the filter types partially retained at least some of the drugs in the final extracts. In testing by flow-injection analysis, all of the membrane filters were also observed to leach interfering components. Ultimately, filtration was avoided altogether in the final sample preparation approach known as the quick, easy, cheap, effective, rugged, safe, efficient, and robust (QuEChERSER) mega-method, and ultracentrifugation was chosen as an alternative.


Assuntos
Resíduos de Drogas , Drogas Veterinárias , Animais , Bovinos , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas , Cromatografia Líquida , Cromatografia Líquida de Alta Pressão/métodos , Antibacterianos/análise , Drogas Veterinárias/análise , Resíduos de Drogas/análise
2.
Sensors (Basel) ; 23(19)2023 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-37837121

RESUMO

Exosomes have gained recognition in cancer diagnostics and therapeutics. However, most exosome isolation methods are time-consuming, costly, and require bulky equipment, rendering them unsuitable for point-of-care (POC) settings. Microfluidics can be the key to solving these challenges. Here, we present a double filtration microfluidic device that can rapidly isolate exosomes via size-exclusion principles in POC settings. The device can efficiently isolate exosomes from 50-100 µL of plasma within 50 min. The device was compared against an already established exosome isolation method, polyethylene glycol (PEG)-based precipitation. The findings showed that both methods yield comparable exosome sizes and purity; however, exosomes isolated from the device exhibited an earlier miRNA detection compared to exosomes obtained from the PEG-based isolation. A comparative analysis of exosomes collected from membrane filters with 15 nm and 30 nm pore sizes showed a similarity in exosome size and miRNA detection, with significantly increased sample purity. Finally, TEM images were taken to analyze how the developed devices and PEG-based isolation alter exosome morphology and to analyze exosome sizes. This developed microfluidic device is cost-efficient and time-efficient. Thus, it is ideal for use in low-resourced and POC settings to aid in cancer and disease diagnostics and therapeutics.


Assuntos
Exossomos , MicroRNAs , Neoplasias , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Microfluídica
3.
AAPS PharmSciTech ; 23(7): 233, 2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36002610

RESUMO

The manufacturing of biopharmaceutical drug solutions can involve close contact with various polymeric components, including common filter membranes. Potential leachable substances from filters may interact with the protein and thereby increase the structural damage and aggregation. The main aim of the study deals with the assessment of extractable and leachable (E/L) from different filters and the potential effect of E/Ls on protein (human granulocyte-colony stimulating factor (rh-GCSF) stability. The present study examines the E/L profile of five different polymeric filter membranes using various chromatographic techniques including LC-MS and GC-MS. In order to investigate their effect on protein stability, G-CSF (human granulocyte colony-stimulating factor) formulations were spiked with filter leachable stock solutions at two different pH levels. The spiked formulations were further analyzed with respect to their aggregation behavior. The results demonstrated a higher E/L content in the case of polyamide (PA), polycarbonate (PC), and polyethersulfone (PES) filters as compared to the polytetrafluoroethylene (PTFE) and regenerative cellulose (RC) filter materials. The E/L from RC and PES was found surface-active, whereas E/L from PA and RC significantly altered the particle size/structure resulting in the aggregation of proteins. Furthermore, bisphenol A was found to be one of the E/L substances from PC filters and can impose significant health problems when administered along with pharmaceutical products. The present study reports a qualitative rank ordering of the filter membranes in terms of their propensity to generate E/Ls and thus can be helpful in selecting a suitable membrane filter.


Assuntos
Celulose , Proteínas , Cromatografia Líquida , Contaminação de Medicamentos/prevenção & controle , Embalagem de Medicamentos , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Espectrometria de Massas , Preparações Farmacêuticas , Proteínas/química
4.
Dis Aquat Organ ; 144: 61-73, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33764314

RESUMO

Currently, the prevalence of salmonid alphavirus (SAV) in Norwegian Atlantic salmon farms is largely surveyed via sacrificing fish and sampling of organ tissue on a monthly basis. However, a more cost-efficient, straightforward, rapid, reliable, reproducible and animal welfare friendly method based on the detection of SAV in water could be considered as an alternative method. In the present study, such a method was developed and optimized through a 6 wk cohabitant challenge trial, using post-smolt Atlantic salmon Salmo salar L challenged with high or low doses of SAV subtype 3 (SAV3). Tank water and tissue samples from cohabitant fish were collected at 16 time points. SAV3 was concentrated from the water by filtration, using either electronegative or electropositive membrane filters, which were subsequently rinsed with one of 4 different buffer solutions. SAV3 was detected first in tank water (7 d post-challenge, DPC), and later in cohabitant fish organ tissue samples (12 DPC). The electronegative filter (MF-Millipore™) and rinsing with NucliSENS® easyMAG® Lysis Buffer presented the best SAV3 recovery. A significant positive correlation was found between SAV3 in the tank water concentrates and the mid-kidney samples. Based on these results, detection of SAV3 in filtrated seawater is believed to have the potential to serve as an alternative method for surveillance of SAV in Atlantic salmon farms.


Assuntos
Infecções por Alphavirus , Alphavirus , Doenças dos Peixes , Salmo salar , Infecções por Alphavirus/veterinária , Animais , Noruega , Água do Mar
5.
J Aerosol Sci ; 122: 1-10, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30662085

RESUMO

This work reports on qualitative and semi-quantitative elemental analysis of particulate matter (PM) collected on PTFE membrane filters, for a source apportionment study conducted in Brescia (Italy). Sampling was undertaken in a residential area where an increase in Mn emissions has been highlighted by previous studies. Filters are measured by means of X-ray Fluorescence (XRF) based techniques such as micro-XRF and grazing incidence XRF using synchrotron radiation, Mo or W excitation sources, after applying an automatized sample preparation method. A heterogeneous distribution in PM shape, size and composition was observed, with features typical of anthropogenic sources. XRF measurements performed at various incidence angle, on large areas and different experimental setup were reproducible. The results demonstrate a successful comparison of the various XRF instrumentation, and the decrease in Mn content with the distance away from the identified emission source. This work highlights the potentialities of the presented approach to provide a full quantitative analysis, and ascertain its suitability for providing a direct, fast, simple and sensitive elemental analysis of filters in source apportionment studies and screening purposes.

6.
Environ Pollut ; 341: 122936, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37979648

RESUMO

Water pollution via natural and anthropogenic activities has become a global problem, which can lead to short and long-term impacts on humans' health and the ecosystems. Substantial amounts of individual or mixtures of organic pollutants move into the surface water via point and non-point source contamination. Some of these compounds are known to be toxic and difficult to remove from water sources, thus affecting their quality. Moreover, environmental regulations in high-income countries have become very strict for drinking water treatment over the past decades, especially regarding pesticides. This study aimed to evaluate the efficiency of different residential water treatments to remove 13 pesticides with distinct physicochemical characteristics from the drinking water. Nine water treatments were used: four membrane filters, an activated carbon filter, ultraviolet radiation, reverse osmosis, ion exchange resins, and ozonation. The trial was performed with tap water contaminated with an environmental concentration of 13 pesticides. According to the results, activated carbon and reverse osmosis were 100% efficient for pesticide removal, followed by ion exchange resins and ultraviolet radiation. Membrane filters, in general, showed low efficiency and should, therefore, not be used for this purpose.


Assuntos
Água Potável , Praguicidas , Poluentes Químicos da Água , Purificação da Água , Humanos , Carvão Vegetal , Ecossistema , Raios Ultravioleta , Purificação da Água/métodos , Resinas de Troca Iônica
7.
Water Res ; 268(Pt A): 122586, 2024 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-39413709

RESUMO

Passing through a 0.45 µm filter can significantly alter the concentrations of dissolved trace elements (TEs) in organic-rich waters of the Boreal Zone. However, little evidence has been provided about the impacts of filtration on the size distribution of dissolved TEs. This limitation hinders our comprehension of how filtration affects the assessment of the potentially bioavailable forms of dissolved TEs (i.e. ions and small molecules). Using AF4-UV-ICP-MS, this study systematically investigates such artefacts and their influence on the concentrations of dissolved, primarily ionic, and colloid-associated TEs in river waters and peat bog waters of the Boreal Zone. In river waters (circumneutral pH), membrane filtration had a significant impact on TEs that are associated with inorganic colloids such as Al, Mn, Fe, As, the rare earth elements, Pb, and Th. Approximately 20-80 % of primarily ionic TEs (< 0.5 kDa) and 100 % of large inorganic (ca. 40-300 nm) TEs were excluded from the filtrates under clogged conditions. In contrast, little impact of filtration was observed for bog waters (pH 4). Similarly, cartridge filtration of river waters also led to a decrease in concentrations and size distributions of dissolved TEs. However, cartridge filtration demonstrated a higher efficiency in allowing the passage of ions and excluding colloids than membrane filtration. On average, the ratio of the dissolved concentrations between a cartridge and a membrane filtrate was 1.0 ± 0.2. For primarily ionic species, the average ratio was 1.4 ± 0.4, while for colloidal species, it was 0.4 ± 0.1. Therefore, despite having similar dissolved concentrations, filtration methods with the same nominal pore size can yield different concentrations of bioavailable forms of TEs. These findings may be important for studies of the environmental relevance of dissolved TEs in surface waters of the Boreal Zone, and organic-rich waters elsewhere.

8.
ACS Appl Mater Interfaces ; 15(21): 26069-26080, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37192384

RESUMO

Tangent flow-driven ultrafiltration (TF-UF) is an efficient isolation process of milk exosomes without morphological deformation. However, the TF-UF approach with micro-ultrafiltration SiNx membrane filters suffers from the clogging and fouling of micro-ultrafiltration membrane filter pores with large bioparticles. Thus, it is limited in the long term, continuous isolation of large quantities of exosomes. In this work, we introduced electrophoretic oscillation (EPO) in the TF-UF approach to remove pore clogging and fouling of with micro-ultrafiltration SiNx membrane filters by large bioparticles. As a result, the combined EPO-assisted TF (EPOTF) filtration can isolate large quantities of bovine milk exosomes without deformation. Furthermore, several morphological and biological analyses confirmed that the EPOTF filtration approach could isolate the milk exosomes in high concentrations with high purity and intact morphology. In addition, the uptake test of fluorescent-labeled exosomes by the keratinocyte cells visualized the biological function of purified exosomes. Hence, compared to the TF-UF process, the EPOTF filtration produced a higher yield of bovine milk exosomes without stopping the filtering process for over 200 h. Therefore, this isolation process enables scalable and continuous production of morphologically intact exosomes from bovine milk, suggesting that high-quality exosome purification is possible for future applications such as drug nanocarriers, diagnosis, and treatments.


Assuntos
Incrustação Biológica , Exossomos , Animais , Ultrafiltração , Leite , Incrustação Biológica/prevenção & controle , Filtração , Membranas Artificiais
9.
ACS Appl Mater Interfaces ; 15(40): 47145-47157, 2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37783451

RESUMO

Biodegradable polylactic acid (PLA) nanofibrous membranes (NFMs) hold great potential to address the increasing airborne particulate matter (PM) and dramatic accumulation of plastic/microplastic pollution. However, the field of PLA NFM-based filters is still in its infancy, frequently dwarfed by the bottlenecks regarding relatively low surface activity, poor electroactivity, and insufficient PM capturing mechanisms. This effort discloses a microwave-assisted approach to minute-level synthesis of dielectric ZIF-8 nanocrystals with high specific surface area (over 1012 m2/g) and ultrasmall size (∼240 nm), which were intimately anchored onto PLA nanofibers (PLA@ZIF-8) by a combined "electrospinning-electrospray" strategy. This endowed the PLA@ZIF-8 NFMs with largely increased electroactivity in terms of elevated dielectric coefficient (an increase of 202%), surface potential (up to 5.8 kV), and triboelectric properties (output voltage of 30.8 V at 10 N, 0.5 Hz). Given the profound control over morphology and electroactivity, the PLA@ZIF-8 NFMs exhibited efficient filtration of PM0.3 (97.1%, 85 L/min) with a decreased air resistance (592.5 Pa), surpassing that of the pure PLA counterpart (88.4%, 650.9 Pa). This was essentially ascribed to realization of multiple filtration mechanisms for PLA@ZIF-8 NFMs, including enhanced physical interception, polar interactions, and electrostatic adsorption, and the unique self-charging function triggered by airflow vibrations. Moreover, perfect antibacterial performance was achieved for PLA@ZIF-8, showing ultrahigh inhibition rates of 99.9 and 100% against E. coli and S. aureus, respectively. The proposed hierarchical structuring strategy, offering the multifunction integration unattainable with conventional methods, may facilitate the development of biodegradable long-term air filters.


Assuntos
Nanofibras , Nanofibras/química , Plásticos , Escherichia coli , Staphylococcus aureus , Poliésteres/química , Filtração/métodos
10.
Chemosphere ; 300: 134586, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35427655

RESUMO

Distillery wastewater has high biological and chemical oxygen demand and requires additional treatment before it can be safely discharged into receiving water. It is usually processed through a biomethanation digester and the end product is the post-methanated distillery effluent (PMDE). Research have shown that PMDE released by molasses-based distilleries is a hazardous effluent that can cause harm to the biota and the environment; it contains elevated amount of total dissolved solids (TDS), total suspended solids (TSS) and excess levels of persistent organic compounds (POPs), heavy metals, phenolic compounds, and salts. The practice of wastewater reuse for irrigation in many water scarce countries necessitates the proper treatment of PMDE before it is discharged into receiving water. Convention methods have been in practice for decades, but innovative technologies are needed to enhance the efficiency of PMDE treatment. Advance physical treatment such as membrane separation technology using graphene, ion-exchange and ultrafiltration membranes; chemical treatment such as advanced oxidation methods, electrocoagulation and photocatalytic technologies; biological treatment such as microbial and enzymatic treatment; and hybrid treatment such as microbial-fuel cell (MFC), genetically modified organisms (GMO) and constructed wetland technologies, are promising new methods to improve the quality of PMDE. This review provides insight into current accomplishments evaluates their suitability and discusses future developments in the detoxification of PMDE. The consolidated knowledge will help to develop a better management for the safe disposal and the reuse of PMDE wastewater.


Assuntos
Poluentes Ambientais , Resíduos Industriais , Análise da Demanda Biológica de Oxigênio , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias , Água
11.
Water Res ; 225: 119205, 2022 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-36215843

RESUMO

In most cases, point-of-use tap water quality is not routinely monitored due to widely-dispersed sampling sites and the costly tests. Although previous studies have revealed the variation of drinking water quality during distribution in municipal networks, the influence of aging pipes in buildings on quality is still unknown and this makes it difficult for water utilities to conduct regular maintenance. Herein, we have undertaken a survey of tap water samples across 8 districts in Beijing (China) to evaluate the potential effects of pipe age on point-of-use water quality, including turbidity, organic matter characteristics, and bacterial community. By grouping the collected samples according to the pipe age and source water respectively, the results suggested that bacterial diversity is significantly influenced by the pipe age. However, bacterial community structure is clearly influenced by the source water. Similarly, aging pipes in buildings are also responsible for the deterioration of the final water quality, and their effects have been closely linked to selected water quality parameters by evaluating the relevant factors. Moreover, the interrelationships between physico-chemical parameters and bacteria abundance were identified. For example, pH, Ca2+, Mg2+, Na+ and K+ showed a positive relationship with Bacillus abundance. In addition, an intelligent analysis method for understanding pipe age, organic matter concentration, and hardness (i.e., Ca2+ and Mg2+ concentration), based on image analysis of filtered membranes has been developed. The accuracy of prediction was encouraging, but can be improved with the collection of more data from tap water samples. We expect that this method can be exploited by the public to monitor their tap water and provide a feasible and cost-effective approach for water suppliers to locate aging/deteriorating pipes which need to be replaced or maintained.


Assuntos
Água Potável , Qualidade da Água , Bactérias , China , Microbiologia da Água , Abastecimento de Água
12.
Membranes (Basel) ; 11(5)2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-34065587

RESUMO

Hollow-fiber membrane filters (HFMFs) for household water treatment (HWT) can efficaciously remove disease-causing organisms in laboratory settings. However, lower effectiveness in use in low- and middle-income countries (LMICs) and humanitarian contexts (HCs) has been observed and attributed to membrane fouling and the associated cleaning. In LMICs/HCs, it is not possible to prevent and control fouling using commonly known methods (e.g., testing influent water, maintenance regimes), and the literature on fouling/cleaning of HFMFs distributed in LMICs is scarce. As such, controlled laboratory experiments were conducted to determine the efficacy of locally available (in LMICs/HCs) backwashing solutions at removing fouling using different influent waters and HFMF types. Four commonly distributed HFMFs were selected; fouling layers were developed by filtering three influent water compositions, representing LMIC/HC waters, for 10-days, and bleach, water, or vinegar backwashing solutions were used for daily backwashing. Filter performance indicators included: fiber mechanical properties (strain at break, break force), water quantity performance (flow), water quality performance (turbidity, E. coli), and imaging. The study found fouling developed rapidly and altered mechanical properties and water quantity indicators within 200 h of filtration. Fouling did not decrease water quality indicators. Backwashing improved the filter's mechanical properties and water quantity performance, but it did not fully recover the initial performance. Additionally, recovery differed between backwashing solutions, and no universal cleaning recommendation appropriate for HFMFs in LMICs/HCs was identified. Overall, fouling development and control depended on HFMF type, influent water quality, and backwashing solution type; thus, caution before distributing HFMFs for long-term use in LMICs/HCs is recommended.

13.
J Virol Methods ; 287: 113990, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33035567

RESUMO

Waterborne viral infections represent a major threat to fish health. For many viruses, understanding the interplay between pathogens, host and environment presents a major hurdle for transmission. Salmonid alphavirus (SAV) can infect and cause pancreas disease (PD) in farmed salmonids in seawater. During infection, SAV is excreted from infected fish to the seawater. We evaluated two types of filters and four different eluents, for concentration of SAV3. One L of seawater was spiked with SAV3, followed by filtration and virus elution from membrane filters. For the negatively charged MF hydrophilic membrane filter (MF-) combined with NucliSENS® lysis buffer the SAV3 recovery was 39.5 ±â€¯1.8 % by RT-ddPCR and 25.9 ±â€¯5.7 % by RT-qPCR. The recovery using the positively charged 1 MDS Zeta Plus® Virosorb® membrane filter (MD+), combined with NucliSENS® lysis buffer was 19.0 ±â€¯0.1 % by RT-ddPCR and 13.3 ±â€¯3.8 % by RT-qPCR. The limits of quantification (LOQ) and detection (LOD) were estimated to be 5.18 × 103 and 2.0 × 102 SAV3 copies/L of natural seawater, by RT-ddPCR. SAV3 recovery from small volumes of seawater, and the requirement for standard laboratory equipment, suggest the MF-filter combined with NucliSENS® lysis buffer would be a candidate for further validation in experimental trials.


Assuntos
Infecções por Alphavirus , Alphavirus , Doenças dos Peixes , Salmo salar , Salmonidae , Alphavirus/genética , Animais , Doenças dos Peixes/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Água do Mar
14.
Artigo em Inglês | MEDLINE | ID: mdl-32245064

RESUMO

Determination of Legionella concentrations in water networks is useful for predicting legionellosis risks. The standard culture technique using concentration with membranes filters is the most commonly used method for environmental surveillance of Legionella. The aim of this study was to verify whether filtration with different filter pore sizes (0.2 and 0.45 µm) according to (ISO) 11731:2017, followed by directly placing them on culture media, can influence Legionella detection. Three laboratories participated in an experimental study that tested a known suspension of Legionella pneumophila (Lpn) serogroup 1 (ATCC 33152) (approximate final cell density of 15 CFU/mL). E. coli (ATCC 11775) and Pseudomonas aeruginosa (ATCC 25668) were included as control tests. The average (95% CI) percentage of recovery of Lpn was 65% using 0.45-µm filters and 15% using 0.2-µm filters (p < 0.0001). For control tests, the average (95% CI) percentage of recovery was higher with 0.45 vs. 0.2 µm filters: 97% vs. 64% for Escherichia coli (p < 0.00001) and 105% vs. 97% (p = 0.0244) for P. aeruginosa. Our results showed that the 0.45-µm filters provided the greatest detection of Legionella. Because the current national guidelines leave the choice of membrane porosity to the operator, experimental studies are important for directing operators towards a conscious choice to standardize Legionella environmental surveillance methods.


Assuntos
Legionella pneumophila , Microbiologia da Água , Meios de Cultura , Escherichia coli/isolamento & purificação , Humanos , Legionella pneumophila/isolamento & purificação , Doença dos Legionários/epidemiologia , Água , Abastecimento de Água
15.
Polymers (Basel) ; 12(11)2020 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-33167528

RESUMO

In the last decade, particulate matter (PM) has gradually become a serious public health issue due to its harmful impact on the human body. In this study, we report a novel filtration system for high PM capturing, based on the magnetoelectric (ME) effect that induces an effective surface charge in membrane filters. To elucidate the ME effect on PM capturing, we prepared electrospun poly(vinylidene fluoride)(PVDF)/CoFe2O4(CFO) membranes and investigated their PM capturing efficiency. After electrical poling under a high electric field of 10 kV/mm, PM-capturing efficiencies of the poled-PVDF/CFO membrane filters were improved with carbon/fluorine(C/F) molar ratios of C/F = 4.81 under Hdc = 0 and C/F = 7.01 under Hdc = 700 Oe, respectively. The result illustrates that electrical poling and a dc magnetic field could, respectively, enhance the surface charge of the membrane filters through (i) a strong beta-phase alignment in PVDF (poling effect) and (ii) an efficient shape change of PVDF/CFO membranes (magnetostriction effect). The diffusion rate of a water droplet on the PVDF/CFO membrane surface is reduced from 0.23 to 0.05 cm2/s by covering the membrane surface with PM. Consequently, the PM capturing efficiency is dramatically improved up to 175% from ME membranes with the poling process and applying a magnetic field. Furthermore, the PM was successfully captured on the prototype real mask derived from the magnetoelectric effect induced by a permanent magnet with a diameter of 2 cm without any external power.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA