1.
Small ; : e2401848, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38940626

RESUMO

For every epidemic outbreak, the prevention and treatments in resource-limited areas are always out of reach. Critical to this is that high accuracy, stability, and more comprehensive analytical techniques always rely on expensive and bulky instruments and large laboratories. Here, a fully integrated and high-throughput microfluidic system is proposed for ultra-multiple point-of-care immunoassay, termed Dac system. Specifically, the Dac system only requires a handheld portable device to automatically recycle repetitive multi-step reactions including on-demand liquid releasing, dispensing, metering, collecting, oscillatory mixing, and discharging. The Dac system performs high-precision enzyme-linked immunosorbent assays for up to 17 samples or targets simultaneously on a single chip. Furthermore, reagent consumption is only 2% compared to conventional ELISA, and microbubble-accelerated reactions shorten the assay time by more than half. As a proof of concept, the multiplexed detections are achieved by detecting at least four infection targets for two samples simultaneously on a singular chip. Furthermore, the barcode-based multi-target results can rapidly distinguish between five similar cases, allowing for accurate therapeutic interventions. Compared to bulky clinical instruments, the accuracy of clinical inflammation classification is 92.38% (n = 105), with a quantitative correlation coefficient of R2 = 0.9838, while the clinical specificity is 100% and the sensitivity is 98.93%.

2.
Mol Genet Metab ; 142(1): 108361, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38442492

RESUMO

INTRODUCTION: Phenylketonuria (PKU) requires regular phenylalanine monitoring to ensure optimal outcome. However, home sampling methods used for monitoring suffer high pre-analytical variability, inter-laboratory variability and turn-around-times, highlighting the need for alternative methods of home sampling or monitoring. METHODS: A survey was distributed through email and social media to (parents of) PKU patients and professionals working in inherited metabolic diseases in Denmark, The Netherlands, and United Kingdom regarding satisfaction with current home sampling methods and expectations for future point-of-care testing (POCT). RESULTS: 210 parents, 156 patients and 95 professionals completed the survey. Countries, and parents and patients were analysed together, in absence of significant group differences for most questions. Important results are: 1) Many patients take less home samples than advised. 2) The majority of (parents of) PKU patients are (somewhat) dissatisfied with their home sampling method, especially with turn-around-times (3-5 days). 3) 37% of professionals are dissatisfied with their home sampling method and 45% with the turn-around-times. 4) All responders are positive towards developments for POCT: 97% (n = 332) of (parents of) patients is willing to use a POC-device and 76% (n = 61) of professionals would recommend their patients to use a POC-device. 5) Concerns from all participants for future POC-devices are costs/reimbursements and accuracy, and to professionals specifically, accessibility to results, over-testing, patient anxiety, and patients adjusting their diet without consultation. CONCLUSION: The PKU community is (somewhat) dissatisfied with current home sampling methods, highlighting the need for alternatives of Phe monitoring. POCT might be such an alternative and the community is eager for its arrival.


Assuntos
Pais , Fenilcetonúrias , Testes Imediatos , Humanos , Fenilcetonúrias/diagnóstico , Fenilcetonúrias/sangue , Masculino , Feminino , Inquéritos e Questionários , Pais/psicologia , Coleta de Amostras Sanguíneas , Reino Unido , Países Baixos , Adulto , Satisfação do Paciente , Fenilalanina/sangue , Dinamarca , Criança , Adolescente
3.
Clin Chem Lab Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880779

RESUMO

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.

4.
Clin Chem Lab Med ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38726766

RESUMO

OBJECTIVES: This study aimed to evaluate discrepancies in potassium measurements between point-of-care testing (POCT) and central laboratory (CL) methods, focusing on the impact of hemolysis on these measurements and its impact in the clinical practice in the emergency department (ED). METHODS: A retrospective analysis was conducted using data from three European university hospitals: Technische Universitat Munchen (Germany), Hospital Universitario La Paz (Spain), and Erasmus University Medical Center (The Netherlands). The study compared POCT potassium measurements in EDs with CL measurements. Data normalization was performed in categories for potassium levels (kalemia) and hemolysis. The severity of discrepancies between POCT and CL potassium measurements was assessed using the reference change value (RCV). RESULTS: The study identified significant discrepancies in potassium between POCT and CL methods. In comparing POCT normo- and mild hypokalemia against CL results, differences of -4.20 % and +4.88 % were noted respectively. The largest variance in the CL was a +4.14 % difference in the mild hyperkalemia category. Additionally, the RCV was calculated to quantify the severity of discrepancies between paired potassium measurements from POCT and CL methods. The overall hemolysis characteristics, as defined by the hemolysis gradient, showed considerable variation between the testing sites, significantly affecting the reliability of potassium measurements in POCT. CONCLUSIONS: The study highlighted the challenges in achieving consistent potassium measurement results between POCT and CL methods, particularly in the presence of hemolysis. It emphasised the need for integrated hemolysis detection systems in future blood gas analysis devices to minimise discrepancies and ensure accurate POCT results.

5.
Clin Chem Lab Med ; 62(3): 472-483, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37843302

RESUMO

OBJECTIVES: To develop a sensitive point-of-care testing (POCT) aqueous vascular endothelial growth factor (VEGF) detection system, and assess its role for predicting the response to anti-VEGF treatment in macular edema secondary to retinal vein occlusion (RVO-ME) patients. METHODS: An automatic point-of-care aqueous humor Magnetic Particle Chemiluminescence Enzyme Immuno-Assay (MPCLEIA) VEGF detection system was developed. The predictive values of aqueous cytokine levels, in combination with imaging parameters, on anatomical treatment response (ATR, the relative central macular thickness change [ΔCMT/bl-CMT]) were analyzed. RESULTS: The automatic MPCLEIA system was able to provide results in 45 min with only 20 µL sample. Among the 57 eyes with available pre- and post-treatment evaluation, ATR significantly correlated with levels of interleukin (IL)-6, IL-8, monocyte chemoattractant protein-1 (MCP-1) and VEGF measured by Luminex xMAP platform, and VEGF measured by MPCLEIA. Optimal cut-off values for these biomarkers were 13.26 ng/L, 23.57 ng/L, 1,110.12 ng/L, 105.52 ng/L, and 85.39 ng/L, respectively. Univariate analysis showed significant associations between ATR category (good response if ATR≤-25 % or poor response otherwise) and IL-6, IL-8, MCP-1, VEGF-xMAP, and VEGF-MPCLEIA (p<0.05). Multivariate logistic regression revealed that ATR category was significantly associated with aqueous VEGF-MPCLEIA (p=0.006) and baseline(bl)-CMT (p=0.008). Receiver operating characteristics analysis yielded an AUC of 0.959 for the regression model combining VEGF-MPCLEIA and bl-CMT, for predicting ATR category. CONCLUSIONS: Our novel MPCLEIA-based automatic VEGF detection system enables accurate POCT of aqueous VEGF, which shows promise in predicting the treatment response of RVO-ME to anti-VEGF agents when combined with bl-CMT.


Assuntos
Edema Macular , Fator A de Crescimento do Endotélio Vascular , Humanos , Fator A de Crescimento do Endotélio Vascular/metabolismo , Sistemas Automatizados de Assistência Junto ao Leito , Interleucina-8 , Edema Macular/diagnóstico , Edema Macular/metabolismo , Fatores de Crescimento do Endotélio Vascular/metabolismo , Interleucina-6 , Humor Aquoso/metabolismo
6.
Anal Bioanal Chem ; 416(8): 1971-1982, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38358534

RESUMO

Hand, foot, and mouth disease (HFMD) caused by various enteroviruses is a major public health concern globally. Human enterovirus 71(EVA71), coxsackievirus A16 (CVA16), coxsackievirus A6 (CVA6), and coxsackievirus A10 (CVA10) are four major enteroviruses responsible for HFMD. Rapid, accurate, and specific point-of-care (POC) detection of the four enteroviruses is crucial for the prevention and control of HFMD. Here, we developed two multiplex high-fidelity DNA polymerase loop-mediated isothermal amplification (mHiFi-LAMP) assays for simultaneous detection of EVA71, CVA16, CVA6, and CVA10. The assays have good specificity and exhibit high sensitivity, with limits of detection (LOD) of 11.2, 49.6, 11.4, and 20.5 copies per 25 µL reaction for EVA71, CVA16, CVA6, and CVA10, respectively. The mHiFi-LAMP assays showed an excellent clinical performance (sensitivity 100.0%, specificity 83.3%, n = 47) when compared with four singleplex RT-qPCR assays (sensitivity 93.1%, specificity 100%). In particular, the HiFi-LAMP assays exhibited better performance (sensitivity 100.0%, specificity 100%) for CVA16 and CVA6 than the RT-qPCR assays (sensitivity 75.0-92.3%, specificity 100%). Furthermore, the mHiFi-LAMP assays detected all clinical samples positive for the four enteroviruses within 30 min, obviously shorter than about 1-1.5 h by the RT-qPCR assays. The new mHiFi-LAMP assays can be used as a robust point-of-care testing (POCT) tool to facilitate surveillance of HFMD at rural and remote communities and resource-limited settings.


Assuntos
Enterovirus Humano A , Enterovirus , Doença de Mão, Pé e Boca , Técnicas de Amplificação de Ácido Nucleico , Humanos , Doença de Mão, Pé e Boca/diagnóstico , Enterovirus/genética , Enterovirus Humano A/genética , Técnicas de Diagnóstico Molecular , China/epidemiologia , Filogenia
7.
Methods ; 215: 10-16, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37169320

RESUMO

Prostate specific antigen (PSA) is a widely-used biomarker for the diagnosis, screening, and prognosis of prostate cancer (PCa). It is critical to develop a rapid and convenient method to accurately detect PSA levels, especially when the PSA levels are in the clinical gray area of 4-10 ng/mL. We developed a novel upconversion nanoparticle (UCNP)-based fluorescence lateral flow test strip for qualitatively and quantitatively detecting PSA. The carboxyl group-modified UCNPs (UCNP-COOH) were labeled with anti-PSA antibodies via 1-ethyl-3-(3-(dimethylamino)propyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as labeling probes to recognize PSA. The fluorescence intensity of the UCNP-probe was then measured with a laser fluorescence scanner. A total of 1397 serum and 20 fingertip blood samples were collected to validate the UCNP strip. A reliable correlation between the area ratio (TC), reflecting the fluorescence intensity of the test/control line, and the PSA concentration was observed (r = 0.9986). The dose-dependent luminescence enhancement showed good linearity in the PSA concentration range from 0.1 to 100.0 ng/mL with a detection limit of 0.1 ng/mL. Our UCNP POCT strip demonstrated excellent accuracy, anti-interference and stability in the gray zone (4-10 ng/mL) of PSA clinical application and outperformed other PSA test strips. The UCNP strip showed good consistency with the Roche chemiluminescence assay in 1397 serum samples. It also showed good performance for PSA detection using fingertip blood samples. This novel UCNP-based test strip could be a sensitive and reliable POCT assay to detect PSA, facilitating the diagnosis and surveillance of PCa.


Assuntos
Nanopartículas , Neoplasias da Próstata , Masculino , Humanos , Antígeno Prostático Específico , Luminescência , Neoplasias da Próstata/diagnóstico por imagem , Imunoensaio/métodos
8.
Cell Mol Biol Lett ; 29(1): 34, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38459454

RESUMO

Persistent infection with high-risk human papillomavirus (HR-HPV) is the primary and initiating factor for cervical cancer. With over 200 identified HPV types, including 14 high-risk types that integrate into the host cervical epithelial cell DNA, early determination of HPV infection type is crucial for effective risk stratification and management. Presently, on-site immediate testing during the HPV screening stage, known as Point of Care Testing (POCT), remains immature, severely limiting the scope and scenarios of HPV screening. This study, guided by the genomic sequence patterns of HPV, established a multiplex recombinase polymerase amplification (RPA) technology based on the concept of "universal primers." This approach achieved the multiple amplification of RPA, coupled with the CRISPR/Cas12a system serving as a medium for signal amplification and conversion. The study successfully constructed a POCT combined detection system, denoted as H-MRC12a (HPV-Multiple RPA-CRISPR/Cas12a), and applied it to high-risk HPV typing detection. The system accomplished the typing detection of six high-risk HPV types (16, 18, 31, 33, 35, and 45) can be completed within 40 min, and the entire process, from sample loading to result interpretation, can be accomplished within 45 min, with a detection depth reaching 1 copy/µL for each high-risk type. Validation of the H-MRC12a detection system's reproducibility and specificity was further conducted through QPCR on 34 clinical samples. Additionally, this study explored and optimized the multiplex RPA amplification system and CRISPR system at the molecular mechanism level. Furthermore, the primer design strategy developed in this study offers the potential to enhance the throughput of H-MRC12a detection while ensuring sensitivity, providing a novel research avenue for high-throughput detection in Point-of-Care molecular pathogen studies.


Assuntos
Infecções por Papillomavirus , Recombinases , Humanos , Sistemas CRISPR-Cas/genética , Infecções por Papillomavirus/diagnóstico , Reprodutibilidade dos Testes , Testes Imediatos , Papillomavirus Humano
9.
Mikrochim Acta ; 191(7): 407, 2024 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898338

RESUMO

A smartphone-based electrochemical aptasensing platform was developed for the point-of-care testing (POCT) of carcinoembryonic antigen (CEA) based on the ferrocene (Fc) and PdPt@PCN-224 dual-signal labeled strategy. The prepared PdPt@PCN-224 nanocomposite showed a strong catalytic property for the reduction of H2O2. Phosphate group-labeled aptamer could capture PdPt@PCN-224 by Zr-O-P bonds to form PdPt@PCN-224-P-Apt. Therefore, a dual signal labeled probe was formed by the hybridization between Fc-DNA and PdPt@PCN-224-P-Apt. The presence of CEA forced PdPt@PCN-224-P-Apt to leave the electrode surface due to the specific affinity, leading to the decrease of the reduction current of H2O2. At the same time, the Fc-DNA strand changed to hairpin structure, which made Fc closer to the electrode and resulted in the increase of the oxidation current of Fc. Thus, CEA can be accurately determined through both signals: the decrease of H2O2 reduction current and the increase of Fc oxidation current, which could avoid the false positive signal. Under the optimal conditions, the prepared aptasensor exhibited a wide linear range from 1 pg·mL-1 to 100 ng·mL-1 and low detection limits of 0.98 pg·mL-1 and 0.27 pg·mL-1 with Fc and PdPt@PCN-224 as signal labels, respectively. The aptasensor developed in this study has successfully demonstrated its capability to detect CEA in real human serum samples. These findings suggest that the proposed sensing platform will hold great potential for clinical tumor diagnosis and monitoring.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Antígeno Carcinoembrionário , Técnicas Eletroquímicas , Compostos Ferrosos , Peróxido de Hidrogênio , Limite de Detecção , Paládio , Testes Imediatos , Smartphone , Antígeno Carcinoembrionário/sangue , Antígeno Carcinoembrionário/análise , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Humanos , Técnicas Biossensoriais/métodos , Peróxido de Hidrogênio/química , Paládio/química , Compostos Ferrosos/química , Metalocenos/química , Platina/química
10.
Ter Arkh ; 96(3): 312-314, 2024 Apr 16.
Artigo em Russo | MEDLINE | ID: mdl-38713050

RESUMO

In the article "Point-of-care blood glucose testing: post-market performance assessment of the Accu-Chek Inform II hospital-use glucose meter," published in the Terapevticheskii Arkhiv journal, Vol. 95, No.12, 2023 (DOI: 10.26442/00403660.2023.12.202522), errors were made: the term "measurements at the place of treatment" was changed, as well as the section "Conflict of interest." At the request of the authors' team, errors in the conflict of interest and the wording of the term have been corrected, and the section "Information about the authors" has been updated. The publisher replaced the original version of the published article with the corrected one; the information on the website was also corrected. Correct text of the section "Conflict of interest": Conflict of interest. All authors are not employees or consultants of Roche Diagnostics and have not received any compensation from Roche Diagnostics. Correct wording of the term in Russian: "измерения по месту лечения". Changes were made to the title of the article in Russian: "Измерения глюкозы по месту лечения: пострегистрационное испытание госпитального глюкометра Акку-Чек Информ II", the text of the abstract, keywords, citation, in the text of the article, and abbreviations. Information of the place of work has been updated: Center for Laboratory Diagnostics of the Russian Children Clinical Hospital, a Branch of the Pirogov Russian National Research Medical University. The publisher apologizes to readers and authors for the errors and is confident that the correction of errors will ensure the correct perception and interpretation of the results of the study described in the text.


Assuntos
Glicemia , Humanos , Glicemia/análise , Sistemas Automatizados de Assistência Junto ao Leito , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Testes Imediatos , Vigilância de Produtos Comercializados/métodos , Federação Russa
11.
J Med Virol ; 95(7): e28905, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37386903

RESUMO

The recent major worldwide outbreak of monkeypox virus (MPXV) has highlighted the urgent need for accurate MPXV detection methods. Although quantitative PCR (qPCR) technique is currently the gold standard for MPXV diagnosis, the high costs associated with the technique and the need for complex instrumentation, limits its application in resource-poor settings. CRISPR technology has developed rapidly in recent years and provides an effective tool for point-of-care testing pathogen identification. Here, we exploited the cleavage properties of the Cas12a enzyme and Cas13a enzyme, to detect the MPXV specific genes, F3L gene and B6R gene, respectively. We developed two detection protocols: a 2-step method in which the CRISPR Dual System reaction and the multiplex recombinase polymerase amplification reaction were carried out in separate tubes and a single-tube method in which both reactions were carried out in one tube. Evaluation of the two methods showed that our protocol can detect the MPXV genome down to 10° copies/µL with good specificity and no cross-reactivity with other poxviruses pseudoviruses, and bacteria. Mock positive samples were used to assess clinical applicability, with the results showing satisfactory concordance with the qPCR method for parallel testing. In conclusion, our study provides a reliable molecular diagnostic strategy for detection of MPXV.


Assuntos
Surtos de Doenças , Monkeypox virus , Humanos , Monkeypox virus/genética , Reações Cruzadas , Tecnologia , DNA
12.
Clin Chem Lab Med ; 61(7): 1280-1287, 2023 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-37043622

RESUMO

OBJECTIVES: Monitoring quality indicators (QIs) is an important part of laboratory quality assurance (QA). Here, the Canadian Society of Clinical Chemists (CSCC) Point of Care Testing (POCT) and QI Special Interest Groups describe a process for establishing and monitoring QIs for POCT glucose testing. METHODS: Key, error prone steps in the POCT glucose testing process were collaboratively mapped out, followed by risk assessment for each step. Steps with the highest risk and ability to detect a non-conformance were chosen for follow-up. These were positive patient identification (PPID) and repeat of critically high glucose measurements. Participating sites were asked to submit aggregate data for these indicators from their site(s) for a one-month period. The PPID QI was also included as part of a national QI monitoring program for which fifty-seven sites submitted data. RESULTS: The percentage of POCT glucose tests performed without valid PPID ranged from 0-87%. Sites without Admission-Discharge-Transfer (ADT) connectivity to POCT meters were among those with the highest percentage of POCT glucose tests performed without valid PPID. The percentage repeated critically high glucose measurements ranged from 0-50%, indicating low compliance with this recommendation. A high rate of discordance was also noted when critically high POCT glucose measurements were repeated, demonstrating the importance of repeat testing prior to insulin administration. CONCLUSIONS: Here, a process for establishing these QIs is described, with preliminary data for two QIs chosen from this process. The findings demonstrate the importance of QIs for identification and comparative performance monitoring of non-conformances to improve POCT quality.


Assuntos
Glucose , Sistemas Automatizados de Assistência Junto ao Leito , Indicadores de Qualidade em Assistência à Saúde , Canadá , Opinião Pública , Glucose/química , Testes Imediatos , Humanos
13.
Clin Chem Lab Med ; 61(9): 1572-1579, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37267483

RESUMO

The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) Committee on Point-of-Care Testing (C-POCT) supports the use of point-of-care testing (POCT) outside of the hospital setting performed by healthcare professionals without formal laboratory education because of its numerous benefits. However, these benefits are associated with risks that must be managed, to ensure the provision of reliable test results and minimize harm to the patient. Healthcare professionals, local regulatory bodies, accredited laboratories as well as manufacturers should actively be engaged in education, oversight and advice to ensure that the healthcare professional selects the appropriate equipment and is able to analyze, troubleshoot and correctly interpret the point-of-care (POC) test results.


Assuntos
Hospitais , Testes Imediatos , Humanos , Consenso , Laboratórios , Atenção à Saúde , Sistemas Automatizados de Assistência Junto ao Leito
14.
Anal Bioanal Chem ; 415(14): 2655-2664, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36995409

RESUMO

Acetylcholinesterase (AChE), a crucial enzyme related to liver function, is involved in numerous physiological processes such as neurotransmission and muscular contraction. The currently reported techniques for detecting AChE mainly rely on a single signal output, limiting their high-accuracy quantification. The few reported dual-signal assays are challenging to implement in dual-signal point-of-care testing (POCT) because of the need for large instruments, costly modifications, and trained operators. Herein, we report a colorimetric and photothermal dual-signal POCT sensing platform based on CeO2-TMB (3,3',5,5'-tetramethylbenzidine) for the visualization of AChE activity in liver-injured mice. The method compensates for the false positives of a single signal and realizes the rapid, low-cost portable detection of AChE. More importantly, the CeO2-TMB sensing platform enables the diagnosis of liver injury and provides an effective tool for studying liver disease in basic medicine and clinical applications. Rapid colorimetric and photothermal biosensor for sensitive detection of acetylcholinesterase (I) and acetylcholinesterase levels in mouse serum (II).


Assuntos
Acetilcolinesterase , Técnicas Biossensoriais , Camundongos , Animais , Colorimetria/métodos , Fígado , Benzidinas , Técnicas Biossensoriais/métodos
15.
Environ Res ; 238(Pt 2): 117177, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37751831

RESUMO

The need for novel healthcare treatments and drugs has increased due to the expanding human population, detection of newer diseases, and looming pandemics. The development of nanotechnology offers a platform for cutting-edge in vivo non-invasive monitoring and point-of-care-testing (POCT) for rehabilitative disease detection and management. The advancement and uses of nanobiosensors are currently becoming more common in a variety of scientific fields, such as environmental monitoring, food safety, biomedical, clinical, and sustainable healthcare sciences, since the advent of nanotechnology. The identification and detection of biological patterns connected to any type of disease (communicable or not) have been made possible in recent years by several sensing techniques utilizing nanotechnology concerning biosensors and nanobiosensors. In this work, 2218 articles are drawn and screened from six digital databases out of which 17 were shortlisted for this review by using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) technique. As a result, this study uses a systematic methodology to review some recently developed extremely sensitive nanobiosensors, along with their biomedical, point-of-care diagnostics (POCD), or healthcare applications and their capabilities, particularly for the prediction of some fatal diseases based on a few of the most recent publications. The potential of nanobiosensors for medicinal, therapeutic, or other sustainable healthcare applications, notably for ailments diagnostics, is also recognized as a way forward in the manifestation of future trends.


Assuntos
Técnicas Biossensoriais , Nanotecnologia , Humanos , Nanotecnologia/métodos , Pandemias , Inocuidade dos Alimentos , Atenção à Saúde
16.
Sens Actuators B Chem ; 379: 133244, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36589905

RESUMO

Nucleic acid amplification is crucial for disease diagnosis, especially lethal infectious diseases such as COVID-19. Compared with PCR, isothermal amplification methods are advantageous for point-of-care testing (POCT). However, complicated primer design limits their application in detecting some short targets or sequences with abnormal GC content. Herein, we developed a novel linear displacement isothermal amplification (LDIA) method using two pairs of conventional primers and Bacillus stearothermophilus (Bst) DNA polymerase, and reactions could be accelerated by adding an extra primer. Pseudorabies virus gE (high GC content) and Salmonella fimW (low GC content) genes were used to evaluate the LDIA assay. Using strand displacement (SD) probes, a LDIA-SD method was developed to realize probe-based specific detection. Additionally, we incorporated a nucleic acid-free extraction step and a pocket-sized device to realize POCT applications of the LDIA-SD method. The LDIA-SD method has advantages including facile primer design, high sensitivity and specificity, and applicability for POCT, especially for amplification of complex sequences and detection of infectious diseases.

17.
Am J Emerg Med ; 71: 139-143, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37392513

RESUMO

BACKGROUND: Non-ST-segment elevation myocardial infarction (NSTEMI) is a common form of acute myocardial infarction and rapid and accurate diagnosis is crucial for timely treatment. Current guidelines recommend using high-sensitivity cardiac troponin (hs-cTn) assays to determine circulating cTnI or cTnT levels. While the accuracy of the 0 h/1 h algorithm for diagnosing NSTEMI in different regions and patient populations remains controversial. Additionally, point-of-care testing (POCT) cTn assays have the potential to provide troponin readings to physicians within 15 min, but their accuracy in diagnosing NSTEMI in the emergency department (ED) requires further investigation. METHODS: A single-center prospective observational cohort study was conducted at Shaanxi Provincial People's Hospital to assess the analytical and diagnostic performance of the laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm with Radiometer AQT90-flex POCT cTnT assay in undifferentiated chest pain patients presenting to the ED. Whole-blood samples were collected and hs-cTnT and POCT cTnI were measured simultaneously at baseline and after 1 h. RESULTS: The study results showed that the POCT cTnT assay using the 0 h/1 h algorithm had comparable diagnostic accuracy to the laboratory-based Roche Modular E170 hs-cTnT assay in diagnosing NSTEMI in patients with chest pain. CONCLUSION: The laboratory-based Roche Modular E170 hs-cTnT using the 0 h/1 h algorithm is reliable and accurate method for diagnosing NSTEMI in undifferentiated chest pain patients presenting to the ED. POCT cTnT assay has comparable diagnostic accuracy to the hs-cTnT assay and its rapid turnaround time makes it a valuable tool in expediting the diagnostic workup of chest pain patients.


Assuntos
Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Estudos Prospectivos , Dor no Peito/diagnóstico , Dor no Peito/etiologia , Troponina T , Troponina I , Algoritmos , Serviço Hospitalar de Emergência , Biomarcadores
18.
Can J Anaesth ; 70(12): 1970-1977, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919630

RESUMO

PURPOSE: While the Nova StatStrip® Glucose Hospital Meter System (Nova Biomedical, Waltham, MA, USA) is approved for point-of-care testing (POCT) in critically ill patients, its use during major abdominal surgery has not been evaluated. The purpose of this study was to assess the accuracy of the Nova StatStrip glucometer in patients undergoing major hepatobiliary procedures using the Parkes error grid (ISO15197:2013) and criteria defined by the Clinical and Laboratory Standards Institute (CLSI) POCT12-A3 guideline. METHODS: This study was a post hoc exploratory study of patients participating in a prospective randomized controlled trial on the effects of hyperinsulinemic normoglycemia (HNC) on infectious outcomes after hepatobiliary surgery. Arterial blood samples were collected before surgery and one hour, two hours, and three hours after baseline. Blood glucose levels were analyzed by the Nova StatStrip glucometer and the GEM® PremierTM 5000 blood gas analyzer. Accuracy of the StatStrip glucometer was assessed using the Parkes error grid for type 1 diabetes mellitus (when 99% of samples were within zones A and B on the Parkes error grid and clinical accuracy was acceptable) and the CLSI POCT12-A3 criteria. RESULTS: Blood glucose levels were analyzed in 135 patients, 70 of whom received the HNC. In the Parkes error grid plotted, all samples at all time-points were within zones A and B. The Nova StatStrip glucometer also satisfied CLSI POCT12-A3 criteria at all time-points. CONCLUSION: The Nova StatStrip glucometer was accurate in patients undergoing major upper abdominal surgery, independent of the administration of high-dose insulin therapy. STUDY REGISTRATION: ClinicalTrials.gov (NCT01528189); registered 7 February 2012.


RéSUMé: OBJECTIF: Bien que le système hospitalier de lecture de la glycémie StatStrip® de Nova (Nova Biomedical, Waltham, MA, É.-U.) soit approuvé pour une utilisation au chevet (ou POCT, pour 'Point of Care Testing') chez la patientèle en état critique, son utilisation n'a pas été évaluée en chirurgie abdominale majeure. L'objectif de cette étude était d'évaluer la précision du glucomètre StatStrip de Nova chez la patientèle bénéficiant d'interventions hépatobiliaires majeures à l'aide de la grille d'erreur de Parkes (ISO15197:2013) et des critères définis par la directive POCT12-A3 du Clinical and Laboratory Standards Institute (CLSI). MéTHODE: Il s'agissait d'une étude exploratoire post-hoc auprès de patient·es participant à une étude randomisée contrôlée prospective sur les effets de la normoglycémie hyperinsulinémique (HNC) sur les issues infectieuses après une chirurgie hépatobiliaire. Des échantillons de sang artériel ont été prélevés avant la chirurgie et une heure, deux heures et trois heures après l'échantillon initial. Les taux de glycémie ont été analysés avec le glucomètre StatStrip de Nova et l'analyseur de gaz sanguin GEM® PremierTM 5000. La précision du glucomètre StatStrip a été évaluée à l'aide de la grille d'erreur de Parkes pour le diabète sucré de type 1 (lorsque 99 % des échantillons se trouvaient dans les zones A et B de la grille d'erreur de Parkes et que la précision clinique était acceptable) et des critères POCT12-A3 du CLSI. RéSULTATS: La glycémie a été analysée chez 135 personnes, dont 70 ont reçu une normoglycémie hyperinsulinémique. Dans la grille d'erreur de Parkes tracée, tous les échantillons à tous les points temporels se trouvaient dans les zones A et B. Le glucomètre StatStrip de Nova a également satisfait aux critères POCT12-A3 du CLSI à tous les points temporels. CONCLUSION: Le glucomètre StatStrip de Nova était précis chez la patientèle bénéficiant d'une chirurgie abdominale supérieure majeure, indépendamment de l'administration d'insulinothérapie à forte dose. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT01528189); enregistrée le 7 février 2012.


Assuntos
Glicemia , Hipoglicemia , Humanos , Gasometria , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto
19.
J Fish Dis ; 46(2): 137-146, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36336976

RESUMO

Decapod iridescent virus 1 (DIV1), White spot syndrome virus (WSSV), and Enterocytozoon hepatopenaei (EHP) pose serious threats to the shrimp farming. To date, early detection remains an important way to control the occurrence and diffusion of these pathogens. Here, we developed for the first time, a loop-mediated isothermal amplification (LAMP)-based microfluidic chip detection system, which could detect DIV1, WSSV, and EHP simultaneously. The limits of detection (LoD) of the system were 10 copies/reaction for EHP and DIV1, and 102 copies/reaction for WSSV. The entire detection procedure could be completed rapidly in 40 min at 63°C with 100% specificity and had no cross-reaction with other common shrimp pathogens. This newly established method was further validated using 94 Penaeus vannamei clinical samples, which were comparable to a typical qPCR assay and revealed good stability and reproducibility. These results illustrate that this LAMP microfluidic chip detection system allows rapid triplex pathogen analysis and could satisfy the demands of the field and routine diagnoses in aquaculture.


Assuntos
Doenças dos Peixes , Penaeidae , Viroses , Animais , Microfluídica , Técnicas de Amplificação de Ácido Nucleico/veterinária , Técnicas de Amplificação de Ácido Nucleico/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Mikrochim Acta ; 191(1): 65, 2023 12 29.
Artigo em Inglês | MEDLINE | ID: mdl-38158397

RESUMO

Microfluidic point-of-care testing (POCT) chips are used to enable the mixing and reaction of small sample volumes, facilitating target molecule detection. Traditional methods for actuating POCT chips rely on external pumps or power supplies, which are complex and non-portable. The development of finger-actuated chips has reduced operational difficulty and improved portability, promoting the development of POCT chips. This paper reviews the significance, developments, and potential applications of finger-actuated POCT chips. Three methods for controlling the flow accuracy of finger-actuated chips are summarized: direct push, indirect control, and sample injection control method, along with their respective advantages and disadvantages. Meanwhile, a comprehensive analysis of multi-fluid driving modes is provided, categorizing them into single-push multi-driving and multi-push multi-driving modes. Furthermore, recent research breakthroughs in finger-actuated chips are thoroughly summarized, and their structures, driving, and detection methods are discussed. Finally, this paper discusses the driving performance of finger-actuated chips, the suitability of detection scenarios, and the compatibility with existing detection technologies. It also provides prospects for the future development and application of finger-actuated POCT chips.


Assuntos
Dispositivos Lab-On-A-Chip , Testes Imediatos