Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.439
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Annu Rev Med ; 75: 475-492, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37989145

RESUMO

Cardiac pacing to treat bradyarrhythmias has evolved in recent decades. Recognition that a substantial proportion of pacemaker-dependent patients can develop heart failure due to electrical and mechanical dyssynchrony from traditional right ventricular apical pacing has led to development of more physiologic pacing methods that better mimic normal cardiac conduction and provide synchronized ventricular contraction. Conventional biventricular pacing has been shown to benefit patients with heart failure and conduction system disease but can be limited by scarring and fibrosis. His bundle pacing and left bundle branch area pacing are novel techniques that can provide more physiologic ventricular activation as an alternative to conventional or biventricular pacing. Leadless pacing has emerged as another alternative pacing technique to overcome limitations in conventional transvenous pacemaker systems. Our objective is to review the evolution of cardiac pacing and explore these new advances in pacing strategies.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Ventrículos do Coração , Insuficiência Cardíaca/terapia , Resultado do Tratamento
2.
Circulation ; 149(5): 379-390, 2024 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-37950738

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) may be associated with greater improvement in left ventricular ejection fraction and reduction in death or heart failure hospitalization compared with biventricular pacing (BVP) in patients requiring cardiac resynchronization therapy. We sought to compare the occurrence of sustained ventricular tachycardia (VT) or ventricular fibrillation (VF) and new-onset atrial fibrillation (AF) in patients undergoing BVP and LBBAP. METHODS: The I-CLAS study (International Collaborative LBBAP Study) included patients with left ventricular ejection fraction ≤35% who underwent BVP or LBBAP for cardiac resynchronization therapy between January 2018 and June 2022 at 15 centers. We performed propensity score-matched analysis of LBBAP and BVP in a 1:1 ratio. We assessed the incidence of VT/VF and new-onset AF among patients with no history of AF. Time to sustained VT/VF and time to new-onset AF was analyzed using the Cox proportional hazards survival model. RESULTS: Among 1778 patients undergoing cardiac resynchronization therapy (BVP, 981; LBBAP, 797), there were 1414 propensity score-matched patients (propensity score-matched BVP, 707; propensity score-matched LBBAP, 707). The occurrence of VT/VF was significantly lower with LBBAP compared with BVP (4.2% versus 9.3%; hazard ratio, 0.46 [95% CI, 0.29-0.74]; P<0.001). The incidence of VT storm (>3 episodes in 24 hours) was also significantly lower with LBBAP compared with BVP (0.8% versus 2.5%; P=0.013). Among 299 patients with cardiac resynchronization therapy pacemakers (BVP, 111; LBBAP, 188), VT/VF occurred in 8 patients in the BVP group versus none in the LBBAP group (7.2% versus 0%; P<0.001). In 1194 patients with no history of VT/VF or antiarrhythmic therapy (BVP, 591; LBBAP, 603), the occurrence of VT/VF was significantly lower with LBBAP than with BVP (3.2% versus 7.3%; hazard ratio, 0.46 [95% CI, 0.26-0.81]; P=0.007). Among patients with no history of AF (n=890), the occurrence of new-onset AF >30 s was significantly lower with LBBAP than with BVP (2.8% versus 6.6%; hazard ratio, 0.34 [95% CI, 0.16-0.73]; P=0.008). The incidence of AF lasting >24 hours was also significantly lower with LBBAP than with BVP (0.7% versus 2.9%; P=0.015). CONCLUSIONS: LBBAP was associated with a lower incidence of sustained VT/VF and new-onset AF compared with BVP. This difference remained significant after adjustment for differences in baseline characteristics between patients with BVP and LBBAP. Physiological resynchronization by LBBAP may be associated with lower risk of arrhythmias compared with BVP.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Terapia de Ressincronização Cardíaca/efeitos adversos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Eletrocardiografia
3.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-38426911

RESUMO

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Resultado do Tratamento , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos , Sistema de Registros , Estimulação Cardíaca Artificial/efeitos adversos
4.
Am J Physiol Gastrointest Liver Physiol ; 326(6): G676-G686, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38591131

RESUMO

The motility of the gastrointestinal tract is coordinated in part by rhythmic slow waves, and disrupted slow-wave patterns are linked to functional motility disorders. At present, there are no treatment strategies that primarily target slow-wave activity. This study assessed the use of pacing to suppress glucagon-induced slow-wave dysrhythmias in the small intestine. Slow waves in the jejunum were mapped in vivo using a high-resolution surface-contact electrode array in pigs (n = 7). Glucagon was intravenously administered to induce hyperglycemia. Slow-wave propagation patterns were categorized into antegrade, retrograde, collision, pacemaker, and uncoupled activity. Slow-wave characteristics such as period, amplitude, and speed were also quantified. Postglucagon infusion, pacing was applied at 4 mA and 8 mA and the resulting slow waves were quantified spatiotemporally. Antegrade propagation was dominant throughout all stages with a prevalence of 55 ± 38% at baseline. However, glucagon infusion resulted in a substantial and significant increase in uncoupled slow waves from 10 ± 8% to 30 ± 12% (P = 0.004) without significantly altering the prevalence of other slow-wave patterns. Slow-wave frequency, amplitude, and speed remained unchanged. Pacing, particularly at 8 mA, significantly suppressed dysrhythmic slow-wave patterns and achieved more effective spatial entrainment (85%) compared with 4 mA (46%, P = 0.039). This study defined the effect of glucagon on jejunal slow waves and identified uncoupling as a key dysrhythmia signature. Pacing effectively entrained rhythmic activity and suppressed dysrhythmias, highlighting the potential of pacing for gastrointestinal disorders associated with slow-wave abnormalities.NEW & NOTEWORTHY Glucagon was infused in pigs to induce hyperglycemia and the resulting slow-wave response in the intact jejunum was defined in high resolution for the first time. Subsequently, with pacing, the glucagon-induced dysrhythmias were suppressed and spatially entrained for the first time with a success rate of 85%. The ability to suppress slow-wave dysrhythmias through pacing is promising in treating motility disorders that are associated with intestinal dysrhythmias.


Assuntos
Motilidade Gastrointestinal , Glucagon , Jejuno , Animais , Suínos , Motilidade Gastrointestinal/fisiologia , Jejuno/fisiopatologia , Intestino Delgado/fisiopatologia , Feminino , Hiperglicemia/terapia , Masculino
5.
J Cardiovasc Electrophysiol ; 35(4): 727-736, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38351331

RESUMO

INTRODUCTION: Clinical outcomes of long-term ventricular septal pacing (VSP) without His-Purkinje capture remain unknown. This study evaluated the differences in clinical outcomes between conduction system pacing (CSP), VSP, and right ventricular pacing (RVP). METHODS: Consecutive patients with bradycardia indicated for pacing from 2016 to 2022 were prospectively followed for the clinical endpoints of heart failure (HF)-hospitalizations and all-cause mortality at 2 years. VSP was defined as septal pacing due to unsuccessful CSP implant or successful CSP followed by loss of His-Purkinje capture within 90 days. RESULTS: Among 1016 patients (age 73.9 ± 11.2 years, 47% female, 48% atrioventricular block), 612 received RVP, 335 received CSP and 69 received VSP. Paced QRS duration was similar between VSP and RVP, but both significantly longer than CSP (p < .05). HF-hospitalizations occurred in 130 (13%) patients (CSP 7% vs. RVP 16% vs. VSP 13%, p = .001), and all-cause mortality in 143 (14%) patients (CSP 7% vs. RVP 19% vs. VSP 9%, p < .001). The association of pacing modality with clinical events was limited to those with ventricular pacing (Vp) > 20% (pinteraction < .05). Adjusting for clinical risk factors among patients with Vp > 20%, VSP (adjusted hazard ratio [AHR]: 4.74, 95% confidence interval [CI]: 1.57-14.36) and RVP (AHR: 3.08, 95% CI: 1.44-6.60) were associated with increased hazard of HF-hospitalizations, and RVP (2.52, 95% CI: 1.19-5.35) with increased mortality, compared to CSP. Clinical endpoints did not differ between VSP and RVP with Vp > 20%, or amongst groups with Vp < 20%. CONCLUSION: Conduction system capture is associated with improved clinical outcomes. CSP should be preferred over VSP or RVP during pacing for bradycardia.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Bradicardia/diagnóstico , Bradicardia/terapia , Bradicardia/etiologia , Prognóstico , Estimulação Cardíaca Artificial/efeitos adversos , Doença do Sistema de Condução Cardíaco , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Fascículo Atrioventricular , Eletrocardiografia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 35(4): 821-831, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38424678

RESUMO

INTRODUCTION: Intrinsic antitachycardia pacing (iATP) is a novel automated antitachycardia pacing (ATP) that provides individual treatment to terminate ventricular tachycardia (VT). However, the clinical efficacy of iATP in comparison with conventional ATP is unknown. We aim to compare the termination rate of VT between iATP and conventional ATP in patients with implantable cardioverter-defibrillators using a unique setting of different sequential orders of both ATP algorisms. METHODS: Patients with the iATP algorithm were assigned to iATP-first and conventional ATP-first groups sequentially. In the iATP-first group, a maximum of seven iATP sequences were delivered, followed by conventional burst and ramp pacing. In contrast, in the conventional ATP-first group, two bursts and ramp pacing were initially programmed, followed by iATP sequences. We compared the success rates of VT termination in the first and secondary programmed ATP zones between the two groups. RESULTS: Fifty-eight and 56 patients were enrolled in the iATP-first and conventional ATP-first groups, and 67 and 44 VTs were analyzed in each group, respectively. At the first single ATP therapy, success rates were 64% and 70% in the iATP and conventional groups, respectively. At the end of the first iATP treatment zone, the success rate increased from 64% to 85%. Moreover, secondary iATP therapy following the failure of conventional ATPs increased the success rate from 80% to 93%. There was a significant benefit of alternative iATP for VT termination compared to secondary conventional ATP (100% vs. 33%, p = .028). CONCLUSIONS: iATP may be beneficial as a secondary therapy after failure of conventional ATP to terminate VT.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do Tratamento , Estimulação Cardíaca Artificial/efeitos adversos , Trifosfato de Adenosina
7.
J Cardiovasc Electrophysiol ; 35(1): 120-129, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37962088

RESUMO

INTRODUCTION: Implant procedure features and clinical implications of left bundle branch pacing (LBBP) and left ventricular septal pacing (LVSP) have not been yet fully described. We sought to compare two different left bundle branch area pacing (LBBAP) implant strategies: the first one accepting LVSP as a procedural endpoint and the second one aiming at achieving LBBP in every patient in spite of evidence of previous LVSP criteria. METHODS: LVSP was accepted as a procedural endpoint in 162 consecutive patients (LVSP strategy group). In a second phase, LBBP was attempted in every patient in spite of achieving previous LVSP criteria (n = 161, LBBP strategy group). Baseline patient characteristics, implant procedure, and follow-up data were compared. RESULTS: The final capture pattern was LBBP in 71.4% and LVSP in 24.2% in the LBBP strategy group compared to 42.7% and 50%, respectively, in the LVSP strategy group. One hundred and eighty-four patients (57%) had proven LBB capture criteria with a significantly shorter paced QRS duration than the 120 patients (37%) with LVSP criteria (115 ± 9 vs. 121 ± 13 ms, p < .001). Implant parameters were comparable between the two strategies but the LBBP strategy resulted in a higher rate of acute septal perforation (11.8% vs. 4.9%, p = .026) without any clinical sequelae. Patients with CRT indications significantly improved left ventricular ejection fraction (LVEF) during follow-up irrespective of the capture pattern (from 35 ± 11% to 45 ± 14% in proven LBBP, p = .024; and from 39 ± 13% to 47 ± 12% for LVSP, p = .003). The presence of structural heart disease and baseline LBBB independently predicted unsuccessful LBB capture. CONCLUSION: The LBBP strategy was associated with comparable implant parameters than the LVSP strategy but resulted in higher rates of septal perforation. Proven LBB capture and LVSP showed comparable effects on LVEF during follow-up.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Volume Sistólico , Eletrocardiografia/métodos , Função Ventricular Esquerda
8.
J Cardiovasc Electrophysiol ; 35(1): 146-154, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37888415

RESUMO

INTRODUCTION: Fusion pacing requires correct timing of left ventricular pacing to right ventricular activation, although it is unclear whether this is maintained when atrioventricular (AV) conduction changes during exercise. We used cardiopulmonary exercise testing (CPET) to compare cardiac resynchronization therapy (CRT) using fusion pacing or fixed AV delays (AVD). METHODS: Patients 6 months post-CRT implant with PR intervals < 250 ms performed two CPET tests, using either the SyncAV™ algorithm or fixed AVD of 120 ms in a double-blinded, randomized, crossover study. All other programming was optimized to produce the narrowest QRS duration (QRSd) possible. RESULTS: Twenty patients (11 male, age 71 [65-77] years) were recruited. Fixed AVD and fusion programming resulted in similar narrowing of QRSd from intrinsic rhythm at rest (p = .85). Overall, there was no difference in peak oxygen consumption (V̇O2 PEAK , p = .19), oxygen consumption at anaerobic threshold (VT1, p = .42), or in the time to reach either V̇O2 PEAK (p = .81) or VT1 (p = .39). The BORG rating of perceived exertion was similar between groups. CPET performance was also analyzed comparing whichever programming gave the narrowest QRSd at rest (119 [96-136] vs. 134 [119-142] ms, p < .01). QRSd during exercise (p = .03), peak O2 pulse (mL/beat, a surrogate of stroke volume, p = .03), and cardiac efficiency (watts/mL/kg/min, p = .04) were significantly improved. CONCLUSION: Fusion pacing is maintained during exercise without impairing exercise capacity compared with fixed AVD. However, using whichever algorithm gives the narrowest QRSd at rest is associated with a narrower QRSd during exercise, higher peak stroke volume, and improved cardiac efficiency.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Idoso , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Estudos Cross-Over , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Frequência Cardíaca , Resultado do Tratamento , Eletrocardiografia
9.
J Cardiovasc Electrophysiol ; 35(5): 1041-1045, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38462703

RESUMO

INTRODUCTION: Transsubclavian venous implantation of the Aveir leadless cardiac pacemaker (LCP) has not been previously reported. METHODS AND RESULTS: Three cases of transsubclavian implantation of the Aveir LCP are reported. Two cases were postbilateral orthotopic lung transplant, without appropriate femoral or jugular access due to recent ECMO cannulation and jugular central venous catheters. In one case, there was strong patient preference for same-day discharge. Stability testing confirmed adequate fixation and electrical testing confirmed stable parameters in all cases. All patients tolerated the procedure well without significant immediate complications. CONCLUSIONS: We demonstrate the feasibility of transsubclavian implantation of the Aveir LCP.


Assuntos
Estimulação Cardíaca Artificial , Veias Jugulares , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Veias Jugulares/cirurgia , Feminino , Idoso , Resultado do Tratamento , Desenho de Equipamento , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos
10.
J Cardiovasc Electrophysiol ; 35(7): 1452-1460, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38757909

RESUMO

INTRODUCTION: Left bundle branch area (LBBA) pacing (LBBAP) has been proposed as an alternative therapy option in patients indicated for cardiac pacing to treat bradycardia or heart failure. The aim of the study was to evaluate the safety and effectiveness of LBBAP in patients implanted with a Tendril 2088 stylet-driven lead. METHODS: The international retrospective data collection registry included 11 sites from 5 countries globally. Patients with attempted implants of the Tendril lead in the LBBA were followed for at least 6 months post the implant attempt. The primary safety and efficacy endpoints were freedom from LBBAP lead-related serious adverse events and the composite of LBBA capture threshold of ≤2.0 V and R-wave amplitudes ≥5 mV (or ≥value at implant), respectively. RESULTS: Of 221 patients with attempted implants of the Tendril 2088 lead in the LBBA, 91.4% (202/221) had successful implants for LBBAP. Regardless of the LBBAP implant success, all patients were followed for at least 6 months (8.7 ± 7.3 months). Baseline characteristics: 44% female, 84% ≥65 years old, 34% coronary artery disease, and 86% of primary indications for pacemaker implant. Both primary safety and effectiveness endpoints were met (freedom from LBBAP lead-related serious adverse device effects of 99.5% and electrical performance composite success rate of 93%). The capture thresholds in LBBAP at implant and 6 months were 0.8 ± 0.3 V@0.4 ± 0.1 ms and 0.8 ± 0.3 V@0.4 ± 0.1 ms. The rate of patients with capture threshold rise ≥1 V was 1.5% through 6 months. The R-wave amplitudes in LBBAP at implant and 6 months were 9.3 ± 3.2 mV and 10.6 ± 3.0 mV. CONCLUSIONS: This large multicenter study demonstrates that the stylet-driven Tendril™ STS 2088 lead is safe and effective for LBBAP with high success and low complication rates.


Assuntos
Potenciais de Ação , Estimulação Cardíaca Artificial , Frequência Cardíaca , Marca-Passo Artificial , Sistema de Registros , Humanos , Feminino , Masculino , Idoso , Estudos Retrospectivos , Fatores de Tempo , Pessoa de Meia-Idade , Resultado do Tratamento , Idoso de 80 Anos ou mais , Bradicardia/fisiopatologia , Bradicardia/terapia , Bradicardia/diagnóstico , Fascículo Atrioventricular/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Fatores de Risco , Desenho de Equipamento
11.
Artigo em Inglês | MEDLINE | ID: mdl-38812213

RESUMO

INTRODUCTION: Left bundle branch area pacing is an alternative to biventricular pacing. In this study, we aim to summarize the available evidence on the feasibility, efficacy, and safety of left bundle branch block area pacing (LBBAP). OBJECTIVES: The study summarizes the available evidence on the feasibility, efficacy, and safety of left bundle branch block area pacing (LBBAP). BACKGROUND: Cardiac resynchronization therapy (CRT) reduced mortality and hospitalizations in heart failure (HF) patients with a left ventricular ejection fraction (LVEF) ≤ 35% and concomitant LBBB. Recently LBBAP has been studied as a more physiological alternative to achieve CRT. METHOD: A search of PubMed, EMBASE, and Cochrane databases were performed to identify studies examining the role of LBBAP for CRT in heart failure. Comprehensive meta-analysis version 4 was used for meta-regression to examine variables that contribute to data heterogeneity. RESULT: Eighteen studies, 17 observational and one randomized controlled trial (RCT) were examined. A total of 3906 HF patients who underwent CRT (2036 LBBAP vs. 1870 biventricular pacing [BVP]) were included. LBBAP was performed successfully in 90.4% of patients. Compared to baseline, LBBAP was associated with a reduction in QRS duration (MD: -47.23 ms 95% confidence interval [CI]: -53.45, -41.01), an increase in LVEF (MD: 15.22%, 95% CI: 13.5, 16.94), and a reduction in NYHA class (MD: -1.23, 95% CI: -1.41, -1.05). Compared to BVP, LBBAP was associated with a significant reduction in QRS duration (MD: -20.69 ms, 95% CI: -25.49, -15.88) and improvement in LVEF (MD: 4.78%, 95% CI: 3.30, 6.10). Furthermore, LBBAP was associated with a significant reduction in HF hospitalization (odds ratio [OR]: 0.44, 95% CI: 0.34, 0.56) and all-cause mortality (OR: 0.67, 95% CI: 0.52, 0.86) compared to BVP. CONCLUSION: LBBAP was associated with improved ventricular electrical synchrony compared to BVP, as well as better echocardiographic and clinical outcomes.

12.
J Cardiovasc Electrophysiol ; 35(5): 906-915, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38433355

RESUMO

INTRODUCTION: Right ventricular (RV) pacing sometimes causes left ventricular (LV) systolic dysfunction, also known as pacing-induced cardiomyopathy (PICM). However, the association between specifically paced QRS morphology and PICM development has not been elucidated. This study aimed to investigate the association between paced QRS mimicking a complete left bundle branch block (CLBBB) and PICM development. METHODS: We retrospectively screened 2009 patients who underwent pacemaker implantation from 2010 to 2020 in seven institutions. Patients who received pacemakers for an advanced atrioventricular block or bradycardia with atrial fibrillation, baseline LV ejection fraction (LVEF) ≥ 50%, and echocardiogram recorded at least 6 months postimplantation were included. The paced QRS recorded immediately after implantation was analyzed. A CLBBB-like paced QRS was defined as meeting the CLBBB criteria of the American Heart Association/American College of Cardiology Foundation/Heart Rhythm Society in 2009. PICM was defined as a ≥10% LVEF decrease, resulting in an LVEF of <50%. RESULTS: Among the 270 patients analyzed, PICM was observed in 38. Baseline LVEF was lower in patients with PICM, and CLBBB-like paced QRS was frequently observed in PICM. Multivariate analysis revealed that low baseline LVEF (odds ratio [OR]: 0.93 per 1% increase, 95% confidence interval [CI]: 0.89-0.98, p = 0.006) and CLBBB-like paced QRS (OR: 2.69, 95% CI: 1.25-5.76, p = 0.011) were significantly associated with PICM development. CONCLUSION: CLBBB-like paced QRS may be a novel risk factor for PICM. RV pacing, which causes CLBBB-like QRS morphology, may need to be avoided, and patients with CLBBB-like paced QRS should be followed-up carefully.


Assuntos
Potenciais de Ação , Bloqueio de Ramo , Estimulação Cardíaca Artificial , Cardiomiopatias , Eletrocardiografia , Frequência Cardíaca , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Bloqueio de Ramo/fisiopatologia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Cardiomiopatias/fisiopatologia , Cardiomiopatias/etiologia , Cardiomiopatias/terapia , Cardiomiopatias/diagnóstico , Diagnóstico Diferencial , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Direita
13.
Artigo em Inglês | MEDLINE | ID: mdl-38664898

RESUMO

BACKGROUND: Although left bundle branch area pacing (LBBAP) has been shown to be a feasible option for delivering physiological pacing, data are largely limited to single-center reports. The aim of this analysis was to systematically assess the safety and efficacy of LBBAP with the Model 3830 lead among primarily bradycardia patients. METHODS AND RESULTS: PubMed, Embase, Cochrane Library, and Google Scholar were searched for full-text articles on LBBAP using the SelectSecure Model 3830 lumenless lead. Rates and means were estimated using random- and mixed-effects models. Of 3395 articles, 53 met inclusion criteria, representing 6061 patients undergoing an implant attempt. Average patient age was 68.1 years (95% CI: 66.6, 69.6) and 53.1% were male (95% CI: 50.5%, 55.7%). The average implant success rate among bradycardia-indicated patients was 92.7% (95% CI: 89.5%, 94.9%). The overall estimated procedural adverse event rate was 2.5% (95% CI: 1.1%, 5.4%). The estimated septal perforation rate at implant was 1.6% (95% CI: 1.0%, 2.6%) with no adverse clinical sequelae reported. Pacing thresholds were low at implant (0.67 V [95% CI: 0.64, 0.70]) and remained stable through 12 months (0.76 V [95% CI: 0.72, 0.80]). Among bradycardia-indicated patients, LVEF remained stable from baseline to post-implant (59.5% [95% CI: 57.9%, 61.1%] vs. 60.1% [95% CI: 58.5%, 61.7%]). CONCLUSION: This meta-analysis including 6061 patients implanted with a Model 3830 lead for LBBAP found an average implant success rate of 92.7% and a procedural adverse event rate of 2.5% with stable electrical parameters and LVEF post-implant.

14.
J Cardiovasc Electrophysiol ; 35(6): 1232-1234, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38534004

RESUMO

INTRODUCTION: Pacemaker implantation can be challenging in patients with congenital heart disease. METHODS AND RESULTS: In a patient with Ebstein disease and symptomatic sinus node dysfunction, despite multiple attempts, the Micra® pacemaker could not be implanted in the severely dilated right ventricle. In that context, and after iodine injection to confirm the appropriate location, the Micra® pacemaker was successfully implanted in the right appendage at the first attempt. CONCLUSION: Despite the recent development of dedicated dual-chamber leadless pacemaker, to the best of our knowledge, this case is the first off-label Micra® implantation in a right appendage.


Assuntos
Apêndice Atrial , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/fisiopatologia , Síndrome do Nó Sinusal/diagnóstico , Anomalia de Ebstein/cirurgia , Anomalia de Ebstein/fisiopatologia , Resultado do Tratamento , Masculino , Desenho de Equipamento
15.
J Cardiovasc Electrophysiol ; 35(4): 802-810, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38409896

RESUMO

INTRODUCTION: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions. METHODS: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34). RESULTS: The paced QRS duration (QRS-d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS-d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS-d and the lead depth. CONCLUSION: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.


Assuntos
Estimulação Cardíaca Artificial , Septo Interventricular , Humanos , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Catéteres , Eletrocardiografia/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Septo Interventricular/diagnóstico por imagem
16.
Artigo em Inglês | MEDLINE | ID: mdl-38896005

RESUMO

INTRODUCTION: The association between paced LVAT and cardiac structure and function at baseline, as well as whether longer LVAT is associated with worse cardiac reverse remodeling in patients with heart failure (HF) and left bundle branch block (LBBB) has not been well investigated. The purpose of this study is to investigate the association between paced LVAT and baseline echocardiographic parameters and cardiac reverse remodeling at follow-up. METHODS: Patients with HF and LBBB receiving successful left bundle branch pacing (LBBP) from June 2018 to April 2023 were enrolled and grouped based on paced LVAT. NT-proBNP and echocardiographic parameters were recorded during routine follow-up. The relationships between paced LVAT and echocardiographic parameters at baseline and follow-up were analyzed. RESULTS: Eighty-three patients were enrolled (48 males, aged 65 ± 9.8, mean LVEF 32.1 ± 7.5%, mean LVEDD 63.0 ± 8.5 mm, median NT-proBNP 1057[513-3158] pg/mL). The paced QRSd was significantly decreased (177 ± 17.9 vs. 134 ± 18.5, p < .001) and median paced LVAT was 80[72-88] ms. After a median follow-up of 12[9-29] months, LVEF increased to 52.1 ± 11.2%, LVEDD decreased to 52.6 ± 8.8 mm, and NT-proBNP decreased to 215[73-532]pg/mL. Patients were grouped based on paced LVAT: LVAT < 80 ms (n = 39); 80 ≤ LVAT < 90 ms (n = 24); LVAT ≥ 90 ms (n = 20). Patients with longer LVAT had larger LVEDD and lower LVEF (LVEDDbaseline: p < .001; LVEFbaseline: p = .001). The difference in LVEF6M was statistically significant among groups (p < .001) and patients with longer LVAT had lower LVEF6M, while the difference in LVEF1Y was not seen (p = .090). There was no significant correlation between ΔLVEF6M-baseline, ΔLVEF1Y-6M and LVAT respectively (ΔLVEF6M-baseline: p = .261, r = -.126; ΔLVEF1Y-6M: p = .085, r = .218). CONCLUSION: Long paced LVAT was associated with worse echocardiographic parameters at baseline, but did not affect the cardiac reverse remodeling in patients with HF and LBBB. Those with longer LVAT required longer time to recover.

17.
J Cardiovasc Electrophysiol ; 35(6): 1115-1120, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38534012

RESUMO

INTRODUCTION: Few studies have demonstrated a high degree of atrioventricular (AV) synchrony with a new leadless pacemaker called Micra AV. Our group previously reported a new and unique sensing method. We believe that this novel sensing method, "Simplified A3 method," might facilitate better AV synchrony than a conventional sensing method in almost all cases with Micra AV implantation. METHODS: We conducted a non-randomized retrospective study comparing the two pacing methods at two centers. From December 1, 2021 to October 31, 2022, Micra AV was implanted for 32 patients at the two centers. Twenty of the 32 patients with sinus rhythm and complete AV block were included in this study. In Group 1, the conventional setting was programmed as follows: auto A3 threshold, auto A3 window-end (WE), and auto A4 threshold turned on during hospitalization. In Group 2, the "Simplified A3 method" was programmed as follows: auto A3 threshold and auto A3WE turned off. Instead, an intentionally prolonged A3WE (850-1000 ms) and low A3 threshold (A3 signal amplitude + 0.5-1.0 m/s2) were programmed. RESULTS: Twenty patients were analyzed. In Group 2, AV synchrony (%AMVp) was significantly higher at the first outpatient clinic (63.0 ± 5.7% vs 81.0 ± 4.2%, p = .03). A3 threshold was significantly lower in Group 2 (5.9 ± 0.7 m/s2, p < .05 vs 2.3 ± 0.5 m/s2, p < .05). CONCLUSION: Our novel sensing method might be a more feasible sensing method for obtaining higher AV synchrony than the conventional algorithm.


Assuntos
Potenciais de Ação , Bloqueio Atrioventricular , Estimulação Cardíaca Artificial , Estudos de Viabilidade , Frequência Cardíaca , Marca-Passo Artificial , Humanos , Masculino , Feminino , Estimulação Cardíaca Artificial/métodos , Estudos Retrospectivos , Idoso , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Resultado do Tratamento , Desenho de Equipamento , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Fatores de Tempo , Valor Preditivo dos Testes , Nó Atrioventricular/fisiopatologia , Processamento de Sinais Assistido por Computador
18.
J Cardiovasc Electrophysiol ; 35(7): 1340-1350, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38686618

RESUMO

BACKGROUND: Severe first-degree atrioventricular (AV) block may produce symptoms similar to heart failure due to AV dyssynchrony, a syndrome termed AV dromotropathy. According to guidelines, it should be considered for permanent pacemaker implantation, yet evidence supporting this treatment is scarce. OBJECTIVES: This study aimed to determine the impact of AV-optimized conduction system pacing (CSP) in patients with symptomatic severe first-degree AV block and echocardiographic signs of AV dyssynchrony. METHODS: Patients with symptomatic first-degree AV block (PR > 250 ms), preserved left ventricular ejection fraction, narrow QRS, and AV dyssynchrony were included in the study. In a single-blind cross-over design, patients were randomized to AV sequential CSP or backup VVI pacing with a base rate of 40 bpm. We compared exercise capacity, echocardiographic parameters, and symptom occurrence at the end of 3 months of each period. RESULTS: Fourteen patients completed the study. During the AV-optimized CSP compared to the backup pacing period, patients achieved a higher workload on exercise test (147.2 ± 50.9 vs. 140.7 ± 55.8 W; p = .032), with a trend towards higher peak VO2 (23.3 ± 7.1 vs. 22.8 ± 7.1 mL/min/kg; p = .224), and higher left ventricular stroke volume (LVSV 74.5 ± 13.8 vs. 66.4 ± 12.5 mL; p < .001). Symptomatic improvement was recorded, with fewer patients reporting general tiredness and 71% of patients preferring the AV-optimized CSP (p = .008). CONCLUSIONS: AV-optimized CSP could improve symptoms, exercise capacity and LVSV in patients with severe first-degree AV block.


Assuntos
Bloqueio Atrioventricular , Estimulação Cardíaca Artificial , Estudos Cross-Over , Tolerância ao Exercício , Frequência Cardíaca , Função Ventricular Esquerda , Humanos , Masculino , Feminino , Resultado do Tratamento , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Idoso , Método Simples-Cego , Pessoa de Meia-Idade , Fatores de Tempo , Potenciais de Ação , Recuperação de Função Fisiológica , Volume Sistólico , Nó Atrioventricular/fisiopatologia , Índice de Gravidade de Doença
19.
J Cardiovasc Electrophysiol ; 35(5): 875-882, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38424662

RESUMO

INTRODUCTION: Left bundle branch pacing (LBBP) is a physiological pacing modality. However, the long procedure and fluoroscopy time of LBBP is still a problem. This study aims to compare the clinical outcomes between transthoracic echocardiography (TTE)- and X-ray-guided LBBP. METHODS: This is a single-center, prospective, randomized controlled study. Consecutive patients who underwent LBBP in our team from June 2022 to November 2022 were enrolled. Procedure and fluoroscopy time, pacing parameters, electrophysiological and echocardiographic characteristics, as well as complications were recorded at implantation and during follow-up. RESULTS: In this study, 60 patients were enrolled and divided into two groups: 30 patients were allocated to the X-ray group and the remaining 30 to the TTE group. There was no significant difference in the success rate between the two groups (86.7% vs. 76.7%, p = .317). The procedure time of TTE group was comparable to that of the X-ray group (9.0 vs. 12.0 min, p = .063). However, the fluoroscopy time in the TTE group was significantly lower than that of the X-ray group (2.5 vs. 5.0 min, p = .002). There were no statistically significant differences in pacing parameters, electrophysiological and echocardiographic characteristics, or complications between the two groups at implantation and during follow-up. CONCLUSION: TTE-guided LBBP is a feasible and safe method. Compared with X-ray, TTE showed a comparable success rate and procedure time, but it could significantly reduce the fluoroscopy time of LBBP.


Assuntos
Bradicardia , Estimulação Cardíaca Artificial , Ecocardiografia , Frequência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Bradicardia/terapia , Bradicardia/fisiopatologia , Bradicardia/diagnóstico , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade , Fatores de Tempo , Potenciais de Ação , Radiografia Intervencionista , Fascículo Atrioventricular/fisiopatologia , Valor Preditivo dos Testes , Fluoroscopia
20.
Artigo em Inglês | MEDLINE | ID: mdl-38946066

RESUMO

The use of CRT-D devices with left ventricular (LV) sensing has created controversy about programming various parameters especially the left ventricular T wave protection (LVTP) designed to prevent the delivery of a pacing stimulus into the LV vulnerable period. Such devices are available from two manufacturers. This review focuses only on those provided by Biotronik. As the LVTP controls LV sensing, some investigators have advocated turning off the LVTP to prevent episodic desynchronization known a CRT pacing interrupt. However, LVTP off reduces but does not eliminate this type of desynchronization if triggering of an LV stimulus upon right ventricular sensing (RVs) is programmed on. Deactivation of the LVTP incurs loss of diagnostic data provided by CRT pacing interrupt itself. By choice, the occurrence of CRT pacing interrupt can be totally eliminated by appropriate programming of the LV upper rate interval, LVTP and triggering of an LV pacing event upon RVs. Various programmability options are available according to clinical circumstances. As a rule, clinical judgement must weigh the potential diagnostic benefit of preserving the LVTP capable of recording of episodic CRT pacing interrupt against the loss of diagnostic benefit when LVTP is programmed off (with or without triggering of an LV stimulus upon RVs).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA