Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 272
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Rev Med Virol ; 34(4): e2569, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38986606

RESUMO

We aimed to assess the performance of Ag-RDT and RT-qPCR with regard to detecting infectious SARS-CoV-2 in cell cultures, as their diagnostic test accuracy (DTA) compared to virus isolation remains largely unknown. We searched three databases up to 15 December 2021 for DTA studies. The bivariate model was used to synthesise the estimates. Risk of bias was assessed using QUADAS-2/C. Twenty studies (2605 respiratory samples) using cell culture and at least one molecular test were identified. All studies were at high or unclear risk of bias in at least one domain. Three comparative DTA studies reported results on Ag-RDT and RT-qPCR against cell culture. Two studies evaluated RT-qPCR against cell culture only. Fifteen studies evaluated Ag-RDT against cell culture as reference standard in RT-qPCR-positive samples. For Ag-RDT, summary sensitivity was 93% (95% CI 78; 98%) and specificity 87% (95% CI 70; 95%). For RT-qPCR, summary sensitivity (continuity-corrected) was 98% (95% CI 95; 99%) and specificity 45% (95% CI 28; 63%). In studies relying on RT-qPCR-positive subsamples (n = 15), the summary sensitivity of Ag-RDT was 93% (95% CI 92; 93%) and specificity 63% (95% CI 63; 63%). Ag-RDT show moderately high sensitivity, detecting most but not all samples demonstrated to be infectious based on virus isolation. Although RT-qPCR exhibits high sensitivity across studies, its low specificity to indicate infectivity raises the question of its general superiority in all clinical settings. Study findings should be interpreted with caution due to the risk of bias, heterogeneity and the imperfect reference standard for infectivity.


Assuntos
COVID-19 , SARS-CoV-2 , Sensibilidade e Especificidade , Humanos , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/patogenicidade , COVID-19/diagnóstico , COVID-19/virologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Reação em Cadeia da Polimerase Via Transcriptase Reversa/normas , Técnicas de Cultura de Células/métodos , Teste para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/métodos , Testes de Diagnóstico Rápido
2.
J Infect Dis ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38531685

RESUMO

BACKGROUND: SARS-CoV-2 antigen-detection rapid diagnostic tests (Ag-RDTs) have become widely utilized but longitudinal characterization of their community-based performance remains incompletely understood. METHODS: This prospective longitudinal study at a large public university in Seattle, WA utilized remote enrollment, online surveys, and self-collected nasal swab specimens to evaluate Ag-RDT performance against real-time reverse transcription polymerase chain reaction (rRT-PCR) in the context of SARS-CoV-2 Omicron. Ag-RDT sensitivity and specificity within 1 day of rRT-PCR were evaluated by symptom status throughout the illness episode and Orf1b cycle threshold (Ct). RESULTS: From February to December 2022, 5,757 participants reported 17,572 Ag-RDT results and completed 12,674 rRT-PCR tests, of which 995 (7.9%) were rRT-PCR-positive. Overall sensitivity and specificity were 53.0% (95% CI: 49.6-56.4%) and 98.8% (98.5-99.0%), respectively. Sensitivity was comparatively higher for Ag-RDTs used 1 day after rRT-PCR (69.0%), 4 to 7 days post-symptom onset (70.1%), and Orf1b Ct ≤20 (82.7%). Serial Ag-RDT sensitivity increased with repeat testing ≥2 (68.5%) and ≥4 (75.8%) days after an initial Ag-RDT-negative result. CONCLUSION: Ag-RDT performance varied by clinical characteristics and temporal testing patterns. Our findings support recommendations for serial testing following an initial Ag-RDT-negative result, especially among recently symptomatic persons or those at high-risk for SARS-CoV-2 infection.

3.
Malar J ; 23(1): 215, 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39026276

RESUMO

BACKGROUND: Pfhrp2 and pfhrp3 deletions are threatening Plasmodium falciparum malaria diagnosis by rapid diagnostic tests (RDT) due to false negatives. This study assesses the changes in the frequencies of pfhrp2 and pfhrp3 deletions (pfhrp2Del and pfhrp3Del, respectively) and the genes in their flaking regions, before and after RDT introduction in Equatorial Guinea. METHODS: A total of 566 P. falciparum samples were genotyped to assess the presence of pfhrp2 and pfhrp3 deletions and their flanking genes. The specimens were collected 18 years apart from two provinces of Equatorial Guinea, North Bioko (Insular Region) and Litoral Province (Continental Region). Orthologs of pfhrp2 and pfhrp3 genes from other closely related species were used to compare sequencing data to assess pfhrp2 and pfhrp3 evolution. Additionally, population structure was studied using seven neutral microsatellites. RESULTS: This study found that pfhrp2Del and pfhrp3Del were present before the introduction of RDT; however, they increased in frequency after their use, reaching more than 15%. Haplotype networks suggested that pfhrp2Del and pfhrp3Del emerged multiple times. Exon 2 of pfhrp2 and pfhrp3 genes had high variability, but there were no significant changes in amino acid sequences. CONCLUSIONS: Baseline sampling before deploying interventions provides a valuable context to interpret changes in genetic markers linked to their efficacy, such as the dynamic of deletions affecting RDT efficacy.


Assuntos
Antígenos de Protozoários , Plasmodium falciparum , Proteínas de Protozoários , Guiné Equatorial , Proteínas de Protozoários/genética , Antígenos de Protozoários/genética , Plasmodium falciparum/genética , Evolução Molecular , Malária Falciparum , Testes Diagnósticos de Rotina , Humanos , Deleção de Sequência , Deleção de Genes
4.
Malar J ; 23(1): 120, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664678

RESUMO

BACKGROUND: The increased availability and use of malaria rapid diagnostic test (RDT) by primary healthcare (PHC) workers has made universal diagnostic testing before malaria treatment more feasible. However, to meaningfully resolve the problem of over-treatment with artemisinin-based combination therapy and the heightened risk of selection pressure and drug resistance, there should be appropriate response (non-prescription of anti-malarial drugs) following a negative RDT result by PHC workers. This study explored the determinants of the use of RDT and anti-malarial drug prescription practices by PHC workers in Ebonyi state, Nigeria. METHODS: Between March 2 and 10, 2020, three focus group discussions were conducted in English with 23 purposively-selected consenting PHC workers involved in the diagnosis and treatment of malaria. Data was analysed thematically as informed by the method by Braun and Clarke. RESULTS: The determinants of the use of RDT for malaria diagnosis were systemic (RDT availability and patient load), provider related (confidence in RDT and the desire to make correct diagnosis, PHC worker's knowledge and training, and fear to prick a patient), client related (fear of needle prick and refusal to receive RDT, and self-diagnosis of malaria, based on symptoms, and insistence on not receiving RDT), and RDT-related (the ease of conducting and interpreting RDT). The determinants of anti-malarial drug prescription practices were systemic (drug availability and cost) and drug related (effectiveness and side-effects of the drugs). The determinants of the prescription of anti-malarial drugs following negative RDT were provider related (the desire to make more money and limited confidence in RDT) and clients' demand while unnecessary co-prescription of antibiotics with anti-malarial drugs following positive RDT was determined by the desire to make more money. CONCLUSIONS: This evidence highlights many systemic, provider, client, and RDT/drug related determinants of PHC workers' use of RDT and anti-malarial drug prescription practices that should provide tailored guidance for relevant health policy actions in Ebonyi state, Nigeria, and similar settings.


Assuntos
Antimaláricos , Testes Diagnósticos de Rotina , Pessoal de Saúde , Malária , Atenção Primária à Saúde , Nigéria , Antimaláricos/uso terapêutico , Testes Diagnósticos de Rotina/estatística & dados numéricos , Malária/tratamento farmacológico , Malária/diagnóstico , Humanos , Pessoal de Saúde/estatística & dados numéricos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Prescrições de Medicamentos/estatística & dados numéricos , Grupos Focais , Pesquisa Qualitativa , Testes de Diagnóstico Rápido
5.
Malar J ; 23(1): 108, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38632640

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) play a significant role in expanding case management in peripheral healthcare systems. Histidine-rich protein-2 (HRP2) antigen detection RDTs are predominantly used to diagnose Plasmodium falciparum infection. However, the evolution and spread of P. falciparum parasite strains with deleted hrp2/3 genes, causing false-negative results, have been reported. This study assessed the diagnostic performance of HRP2-detecting RDTs for P. falciparum cases and the prevalence of pfhrp2/3 deletions among symptomatic patients seeking malaria diagnosis at selected health facilities in southern Ethiopia. METHODS: A multi-health facilities-based cross-sectional study was conducted on self-presenting febrile patients seeking treatment in southern Ethiopia from July to September 2022. A purposive sampling strategy was used to enroll patients with microscopically confirmed P. falciparum infections. A capillary blood sample was obtained to prepare a blood film for microscopy and a RDT using the SD Bioline™ Malaria Pf/Pv Test. Dried blood spot samples were collected for further molecular analysis. DNA was extracted using gene aid kits and amplification was performed using nested PCR assay. Exon 2 of hrp2 and hrp3, which are the main protein-coding regions, was used to confirm its deletion. The diagnostic performance of RDT was evaluated using PCR as the gold standard test for P. falciparum infections. RESULTS: Of 279 P. falciparum PCR-confirmed samples, 249 (89.2%) had successful msp-2 amplification, which was then genotyped for hrp2/3 gene deletions. The study revealed that pfhrp2/3 deletions were common in all health centres, and it was estimated that 144 patients (57.8%) across all health facilities had pfhrp2/3 deletions, leading to false-negative PfHRP2 RDT results. Deletions spanning exon 2 of hrp2, exon 2 of hrp3, and double deletions (hrp2/3) accounted for 68 (27.3%), 76 (30.5%), and 33 (13.2%) of cases, respectively. The study findings revealed the prevalence of P. falciparum parasites lacking a single pfhrp2-/3-gene and that both genes varied across the study sites. This study also showed that the sensitivity of the SD Bioline PfHRP2-RDT test was 76.5% when PCR was used as the reference test. CONCLUSION: This study confirmed the existence of widespread pfhrp2/3- gene deletions, and their magnitude exceeded the WHO-recommended threshold (> 5%). False-negative RDT results resulting from deletions in Pfhrp2/3- affect a country's attempts at malaria control and elimination. Therefore, the adoption of non-HRP2-based RDTs as an alternative measure is required to avoid the consequences associated with the continued use of HRP-2-based RDTs, in the study area in particular and in Ethiopia in general.


Assuntos
Malária Falciparum , Proteínas de Protozoários , Humanos , Antígenos de Protozoários/genética , Estudos Transversais , Testes Diagnósticos de Rotina/métodos , Etiópia/epidemiologia , Deleção de Genes , Histidina/genética , Malária Falciparum/epidemiologia , Plasmodium falciparum/genética , Proteínas de Protozoários/genética
6.
Mol Biol Rep ; 51(1): 716, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38824237

RESUMO

BACKGROUND: Post kala-azar dermal leishmaniasis (PKDL) is a consequential dermal manifestation of visceral leishmaniasis (VL), serving as a parasite reservoir. The traditional diagnostic approach, which requires an invasive skin biopsy is associated with inherent risks and necessitates skilled healthcare practitioners in sterile settings. There is a critical need for a rapid, less invasive method for Leishmania detection. The main objective of this study was to evaluate and compare the diagnostic efficacy of PCR and qPCR in detecting PKDL, utilizing both skin and blood samples and to assess the utility of blood samples for molecular diagnosis. METHODS AND RESULTS: 73 individuals exhibiting clinical symptoms of PKDL and who had tested positive for rK39 rapid diagnostic test (RDT) were enrolled in this study. For the diagnosis of PKDL, both PCR and real-time quantitative PCR (qPCR), employing SYBR Green and TaqMan assays, were performed on blood and skin matched samples. qPCR results using both TaqMan and SYBR Green assay, indicated higher parasite loads in the skin compared to blood, as evident by the Ct values. Importantly, when blood samples were used for PKDL diagnosis by qPCR, an encouraging sensitivity of 69.35% (TaqMan assay) and 79.36% (SYBR Green) were obtained, compared to 8.2% with conventional PCR. CONCLUSION: The findings of the study suggest the potential utility of blood for molecular diagnosis by qPCR, offering a less invasive alternative to skin biopsies in field setting for the early detection of parasitaemia in PKDL patients and effective management and control of the disease.


Assuntos
Leishmaniose Cutânea , Leishmaniose Visceral , Reação em Cadeia da Polimerase em Tempo Real , Humanos , Leishmaniose Visceral/diagnóstico , Leishmaniose Visceral/sangue , Leishmaniose Visceral/parasitologia , Leishmaniose Cutânea/diagnóstico , Leishmaniose Cutânea/parasitologia , Leishmaniose Cutânea/sangue , Leishmaniose Cutânea/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Masculino , Feminino , Adulto , Adolescente , Pele/parasitologia , Pele/patologia , Sensibilidade e Especificidade , Pessoa de Meia-Idade , Carga Parasitária/métodos , Técnicas de Diagnóstico Molecular/métodos , Adulto Jovem , Criança , DNA de Protozoário/genética , DNA de Protozoário/sangue
7.
BMC Oral Health ; 24(1): 429, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38584280

RESUMO

BACKGROUND: Accurate assessment of remaining dentin thickness (RDT) is paramount for restorative decisions and treatment planning of vital teeth to avoid any pulpal injury. This diagnostic accuracy study compared the validity and patient satisfaction of an electrical impedance based device Prepometer™ (Hager & Werken, Duisburg, Germany) versus intraoral digital radiography for the estimation of remaining dentin thickness in carious posterior permanent teeth. METHODS: Seventy patients aged 12-25 years with carious occlusal or proximal permanent vital posterior teeth were recruited. Tooth preparation was performed to receive an adhesive restoration. Pre- and post-excavation RDT were measured radiographically by two calibrated raters using the paralleling periapical technique. Prepometer™ measurements were performed by the operator. Patients rated their satisfaction level with each tool on a 4-point Likert scale and 100 mm visual analog scale (VAS). Inter and intragroup comparisons were analyzed using signed rank test, while agreement between devices and observations was tested using weight kappa (WK) coefficient. RESULTS: the intergroup comparisons showed that, before and after excavation, there was a significant difference between measurements made by both techniques (p < 0.001). After excavation, there was a weak agreement between measurements (WK = 0.2, p < 0.001), whereas before excavation, the agreement was not statistically significant (p = 0.407). Patients were significantly more satisfied with Prepometer™ based on scales and VAS (p < 0.001). CONCLUSION: Prepometer™ could be a viable clinical tool for determining RDT with high patient satisfaction, while radiographs tended to overestimate RDT in relation to the Prepometer™.


Assuntos
Cárie Dentária , Satisfação do Paciente , Humanos , Impedância Elétrica , Intensificação de Imagem Radiográfica , Dentina/diagnóstico por imagem , Cárie Dentária/diagnóstico por imagem , Cárie Dentária/terapia
8.
Emerg Infect Dis ; 29(1): 154-159, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36573593

RESUMO

Pfhrp2 and pfhrp3 gene deletions threaten the use of Plasmodium falciparum malaria rapid diagnostic tests globally. In South Sudan, deletion frequencies were 15.6% for pfhrp2, 20.0% for pfhrp3, and 7.5% for double deletions. Deletions were approximately twice as prevalent in monoclonal infections than in polyclonal infections.


Assuntos
Malária Falciparum , Plasmodium falciparum , Humanos , Plasmodium falciparum/genética , Antígenos de Protozoários/genética , Proteínas de Protozoários/genética , Deleção de Genes , Sudão do Sul , Testes Diagnósticos de Rotina , Malária Falciparum/diagnóstico , Malária Falciparum/epidemiologia
9.
Virol J ; 20(1): 40, 2023 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-36864463

RESUMO

BACKGROUND: Rotavirus A (RVA) infections remain a major cause of severe acute diarrhea affecting children worldwide. To date, rapid diagnostic tests (RDT) are widely used to detect RVA. However, paediatricians question whether the RDT can still detect the virus accurately. Therefore, this study aimed to evaluate the performance of the rapid rotavirus test in comparison to the one-step RT-qPCR method. METHODS: A cross-sectional study was conducted in Lambaréné, Gabon, from April 2018 to November 2019. Stool samples were collected from children under 5 years of age with diarrhoea or a history of diarrhoea within the last 24 h, and from asymptomatic children from the same communities. All stool samples were processed and analysed using the SD BIOLINE Rota/Adeno Ag RDT against a quantitative reverse transcription PCR (RT-qPCR), which is considered the gold standard. RESULTS: For a total of 218 collected stool samples, the overall sensitivity of the RDT was 46.46% (confidence interval (CI) 36.38-56.77), with a specificity of 96.64% (CI 91.62-99.08) compared to one-step RT-qPCR. After confirming the presence or absence of RVA gastroenteritis, the RDT showed suitable results in detecting rotavirus A-associated disease, with a 91% concordance with the RT-qPCR. Furthermore, the performance of this test varied when correlated with seasonality, symptoms, and rotavirus genotype. CONCLUSION: This RDT showed high sensitivity and was suitable for the detection of RVA in patients with RVA gastroenteritis, although some asymptomatic RVA shedding was missed by RT-qPCR. It could be a useful diagnostic tool, especially in low-income countries.


Assuntos
Infecções por Enterovirus , Gastroenterite , Infecções por Rotavirus , Rotavirus , Criança , Humanos , Lactente , Pré-Escolar , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Estudos Transversais , Diarreia/diagnóstico , Rotavirus/genética , Infecções por Rotavirus/diagnóstico
10.
Malar J ; 22(1): 60, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36803858

RESUMO

BACKGROUND: Rapid diagnostic tests (RDTs) are effective tools to diagnose and inform the treatment of malaria in adults and children. The recent development of a highly sensitive rapid diagnostic test (HS-RDT) for Plasmodium falciparum has prompted questions over whether it could improve the diagnosis of malaria in pregnancy and pregnancy outcomes in malaria endemic areas. METHODS: This landscape review collates studies addressing the clinical performance of the HS-RDT. Thirteen studies were identified comparing the HS-RDT and conventional RDT (co-RDT) to molecular methods to detect malaria in pregnancy. Using data from five completed studies, the association of epidemiological and pregnancy-related factors on the sensitivity of HS-RDT, and comparisons with co-RDT were investigated. The studies were conducted in 4 countries over a range of transmission intensities in largely asymptomatic women. RESULTS: Sensitivity of both RDTs varied widely (HS-RDT range 19.6 to 85.7%, co-RDT range 22.8 to 82.8% compared to molecular testing) yet HS-RDT detected individuals with similar parasite densities across all the studies including different geographies and transmission areas [geometric mean parasitaemia around 100 parasites per µL (p/µL)]. HS-RDTs were capable of detecting low-density parasitaemias and in one study detected around 30% of infections with parasite densities of 0-2 p/µL compared to the co-RDT in the same study which detected around 15%. CONCLUSION: The HS-RDT has a slightly higher analytical sensitivity to detect malaria infections in pregnancy than co-RDT but this mostly translates to only fractional and not statistically significant improvement in clinical performance by gravidity, trimester, geography or transmission intensity. The analysis presented here highlights the need for larger and more studies to evaluate incremental improvements in RDTs. The HS-RDT could be used in any situation where co-RDT are currently used for P. falciparum diagnosis, if storage conditions can be adhered to.


Assuntos
Malária Falciparum , Malária , Adulto , Gravidez , Criança , Humanos , Feminino , Plasmodium falciparum , Testes de Diagnóstico Rápido , Sensibilidade e Especificidade , Malária Falciparum/diagnóstico , Malária Falciparum/epidemiologia , Testes Diagnósticos de Rotina/métodos , Antígenos de Protozoários/análise
11.
Malar J ; 22(1): 240, 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37612601

RESUMO

BACKGROUND: Artesunate-amodiaquine (AS-AQ) and artemether-lumefantrine (AL) are the currently recommended first-and second-line therapies for uncomplicated Plasmodium falciparum infections in Chad. This study assessed the efficacy of these artemisinin-based combinations, proportion of day 3 positive patients, proportions of molecular markers associated with P. falciparum resistance to anti-malarial drugs and variable performance of HRP2-based malaria rapid diagnostic tests (RDTs). METHODS: A single-arm prospective study assessing the efficacy of AS-AQ and AL at three sites (Doba, Kelo and Koyom) was conducted between November 2020 to January 2021. Febrile children aged 6 to 59 months with confirmed uncomplicated P. falciparum infection were enrolled sequentially first to AS-AQ and then AL at each site and followed up for 28 days. The primary endpoint was PCR-adjusted adequate clinical and parasitological response (ACPR). Samples collected on day 0 were analysed for mutations in pfkelch13, pfcrt, pfmdr-1, pfdhfr, pfdhps genes and deletions in pfhrp2/pfhrp3 genes. RESULTS: By the end of 28-day follow-up, per-protocol PCR corrected ACPR of 97.8% (CI 95% 88.2-100) in Kelo and 100% in Doba and Kayoma were observed among AL treated patients. For ASAQ, 100% ACPR was found in all sites. All, but one patient, did not have parasites detected on day 3. Out of the 215 day 0 samples, 96.7% showed pfkelch13 wild type allele. Seven isolates carried nonsynonymous mutations not known to be associated artemisinin partial resistance (ART-R). Most of samples had a pfcrt wild type allele (79% to 89%). The most prevalent pfmdr-1 allele detected was the single mutant 184F (51.2%). For pfdhfr and pfdhps mutations, the quintuple mutant allele N51I/C59R/S108N + G437A/540E responsible for SP treatment failures in adults and children was not detected. Single deletion in the pfhrp2 and pfhrp3 gene were detected in 10/215 (4.7%) and 2/215 (0.9%), respectively. Dual pfhrp2/pfhrp3 deletions, potentially threatening the efficacy of HRP2-based RDTs, were observed in 5/215 (2.3%) isolates. CONCLUSION: The results of this study confirm that AS-AQ and AL treatments are highly efficacious in study areas in Chad. The absence of known pfkelch13 mutations in the study sites and the high parasite clearance rate at day 3 suggest the absence of ART-R. The absence of pfdhfr/pfdhps quintuple or sextuple (quintuple + 581G) mutant supports the continued use of SP for IPTp during pregnancy. The presence of parasites with dual pfhrp2/pfhrp3 deletions, potentially threatening the efficacy of HRP2-based RDTs, warrants the continued surveillance. Trial registration ACTRN12622001476729.


Assuntos
Antimaláricos , Artemisininas , Malária Falciparum , Adulto , Feminino , Gravidez , Humanos , Artesunato , Antimaláricos/uso terapêutico , Amodiaquina/uso terapêutico , Combinação Arteméter e Lumefantrina/uso terapêutico , Chade , Estudos Prospectivos , Artemeter , Malária Falciparum/tratamento farmacológico , Artemisininas/uso terapêutico
12.
Epidemiol Infect ; 151: e151, 2023 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-37539522

RESUMO

Laboratory-based case confirmation is an integral part of measles surveillance programmes; however, logistical constraints can delay response. Use of RDTs during initial patient contact could enhance surveillance by real-time case confirmation and accelerating public health response. Here, we evaluate performance of a novel measles IgM RDT and assess accuracy of visual interpretation using a representative collection of 125 sera from the Brazilian measles surveillance programme. RDT results were interpreted visually by a panel of six independent observers, the consensus of three observers and by relative reflectance measurements using an ESEQuant Reader. Compared to the Siemens anti-measles IgM EIA, sensitivity and specificity of the RDT were 94.9% (74/78, 87.4-98.6%) and 95.7% (45/47, 85.5-99.5%) for consensus visual results, and 93.6% (73/78, 85.7-97.9%) and 95.7% (45/47, 85.5-99.5%), for ESEQuant measurement, respectively. Observer agreement, determined by comparison between individuals and visual consensus results, and between individuals and ESEQuant measurements, achieved average kappa scores of 0.97 and 0.93 respectively. The RDT has the sensitivity and specificity required of a field-based test for measles diagnosis, and high kappa scores indicate this can be accomplished accurately by visual interpretation alone. Detailed studies are needed to establish its role within the global measles control programme.


Assuntos
Vírus do Sarampo , Sarampo , Humanos , Brasil/epidemiologia , Testes de Diagnóstico Rápido , Reprodutibilidade dos Testes , Leitura , Imunoglobulina M , Anticorpos Antivirais , Sarampo/diagnóstico , Sarampo/epidemiologia
13.
Sens Actuators B Chem ; 381: 133364, 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-36684645

RESUMO

Since December 2019, the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), has become a priority for public health. Although the lateral flow assay (LFA) sensor has emerged as a rapid and on-site SARS-CoV-2 detection technique, the conventional approach of using gold nanoparticles for the signaling probe had limitations in increasing the sensitivity of the sensor. Herein, our newly suggested methodology to improve the performance of the LFA system could amplify the sensor signal with a facile fabrication method by concentrating fluorescent organic molecules. A large Stokes shift fluorophore (single benzene) was encapsulated into polystyrene nanobeads to enhance the fluorescence intensity of the probe for LFA sensor, which was detected on the test line with a longpass filter under ultraviolet light irradiation. This approach provides comparatively high sensitivity with the limit of detection of 1 ng mL-1 for the SARS-CoV-2 spike protein and a fast detection process, which takes less than 20 min. Furthermore, our sensor showed higher performance than gold nanoparticle-based commercial rapid diagnostics test kits in clinical tests, proving that this approach is more suitable and reliable for the sensitive and rapid detection of viruses, bacteria, and other hazardous materials.

14.
Regul Toxicol Pharmacol ; 142: 105438, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37356612

RESUMO

In this study we evaluated the outcomes of non-clinical toxicity studies of various SARS-CoV-2 vaccines produced with different manufacturing technologies, with focus on Repeated Dose Toxicity (RDT) and Developmental and Reproductive Toxicity (DART) studies. We found that RDT and DART studies at doses relevant for human treatment showed no adverse effects while remaining observations were expected findings including local reactogenicity, immune response and macroscopic findings at the injection site. We have also reviewed the European Medicines Agency (EMA) nonclinical assessment reports for market authorization. Regardless of utilized vaccine manufacturing technology EMA assessment of the non-clinical studies consisted most frequently of comments related to study design, species selection and missing data. Sponsors have often submitted platform studies (vaccine studies with the same technology/construct but using other antigens) as supplementary data. Animal model-based toxicity testing has shown rather small effects, which have been never serious adverse effects. The translational value to support clinical development is mainly to inflammatory effects, indicative of the primary action of the vaccines. From a 3R perspective supportive platform technology data consisting of previously executed RDT and DART studies from the same platform technology are encouraged to be implemented in the vaccine assessment process.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Animais , Humanos , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Vacinas contra COVID-19/toxicidade , SARS-CoV-2 , Testes de Toxicidade , Vacinas
15.
Euro Surveill ; 28(9)2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36862099

RESUMO

BackgroundLateral flow antigen-detection rapid diagnostic tests (Ag-RDTs) for viral infections constitute a fast, cheap and reliable alternative to nucleic acid amplification tests (NAATs). Whereas leftover material from NAATs can be employed for genomic analysis of positive samples, there is a paucity of information on whether viral genetic characterisation can be achieved from archived Ag-RDTs.AimTo evaluate the possibility of retrieving leftover material of several viruses from a range of Ag-RDTs, for molecular genetic analysis.MethodsArchived Ag-RDTs which had been stored for up to 3 months at room temperature were used to extract viral nucleic acids for subsequent RT-qPCR, Sanger sequencing and Nanopore whole genome sequencing. The effects of brands of Ag-RDT and of various ways to prepare Ag-RDT material were evaluated.ResultsSARS-CoV-2 nucleic acids were successfully extracted and sequenced from nine different brands of Ag-RDTs for SARS-CoV-2, and for five of these, after storage for 3 months at room temperature. The approach also worked for Ag-RDTs for influenza virus (n = 3 brands), as well as for rotavirus and adenovirus 40/41 (n = 1 brand). The buffer of the Ag-RDT had an important influence on viral RNA yield from the test strip and the efficiency of subsequent sequencing.ConclusionOur finding that the test strip in Ag-RDTs is suited to preserve viral genomic material, even for several months at room temperature, and therefore can serve as source material for genetic characterisation could help improve global coverage of genomic surveillance for SARS-CoV-2 as well as for other viruses.


Assuntos
COVID-19 , Ácidos Nucleicos , Humanos , Bélgica , Testes de Diagnóstico Rápido , COVID-19/diagnóstico , SARS-CoV-2/genética , Genômica , Teste para COVID-19
16.
J Vector Borne Dis ; 60(4): 449-452, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38174526

RESUMO

Background & objectives: Malaria is a parasitic disease spread by Plasmodium parasite. Microscopy, lateral flow devices such as the Rapid Diagnostic Test (RDT), molecular methods such as Polymerase Chain Reaction (PCR), isothermal methods such as Loop-mediated isothermal amplification (LAMP), and other diagnostic methods are available for malaria. On the other hand, the accuracy of molecular diagnosis is dependent on genomic DNA isolation. A quick method for isolating and subjectively determining the presence of genomic DNA from blood, dried blood spot (DBS), and rapid diagnostic test (RDT), was identified. Methods: We have developed a protocol for isolating DNA from blood, DBS, and RDTs using the HUDSON Buffer (TCEP and EDTA). Isolated genomic DNA was seen with SYBR Safe DNA stain (1X) under a UV transilluminator without running in 0.8 percent gel electrophoresis or using a spectrophotometer. Results: The technique for DNA isolation was accurate for the presence of malaria parasite genomic DNA from positive samples confirmed by microscopy with a sensitivity of 76% and specificity of 78.67% and RDT with a sensitivity of 88% and specificity of 66%. The requirements were minimal, and the process took 30 minutes for a hundred sample processing. Interpretation & conclusion: Finding a fast and reliable method of separating nucleic acids from many samples is crucial. This approach extracts intact genomic DNA in under ten minutes, making it ideal for large-scale investigations.


Assuntos
Malária Falciparum , Malária , Plasmodium , Humanos , Testes de Diagnóstico Rápido , Sensibilidade e Especificidade , Malária/diagnóstico , Plasmodium/genética , Reação em Cadeia da Polimerase , Plasmodium falciparum/genética , Testes Diagnósticos de Rotina/métodos , Malária Falciparum/diagnóstico
17.
Displays ; 78: 102403, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36937555

RESUMO

Nucleic acid testing is currently the golden reference for coronaviruses (SARS-CoV-2) detection, while the SARS-CoV-2 antigen-detection rapid diagnostic tests (RDT) is an important adjunct. RDT can be widely used in the community or regional screening management as self-test tools and may need to be verified by healthcare authorities. However, manual verification of RDT results is a time-consuming task, and existing object detection algorithms usually suffer from high model complexity and computational effort, making them difficult to deploy. We propose LightR-YOLOv5, a compact rotating SARS-CoV-2 antigen-detection RDT results detector. Firstly, we employ an extremely light-weight L-ShuffleNetV2 network as a feature extraction network with a slight reduction in recognition accuracy. Secondly, we combine semantic and texture features in different layers by judiciously combining and employing GSConv, depth-wise convolution, and other modules, and further employ the NAM attention to locate the RDT result detection region. Furthermore, we propose a new data augmentation approach, Single-Copy-Paste, for increasing data samples for the specific task of RDT result detection while achieving a small improvement in model accuracy. Compared with some mainstream rotating object detection networks, the model size of our LightR-YOLOv5 is only 2.03MB, and it is 12.6%, 6.4%, and 7.3% higher in mAP@.5:.95 metrics compared to RetianNet, FCOS, and R3Det, respectively.

18.
Infect Immun ; 90(8): e0016122, 2022 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-35862704

RESUMO

Cholera is an acute watery, diarrheal disease that causes high rates of morbidity and mortality without treatment. Early detection of the etiologic agent of toxigenic Vibrio cholerae is important to mobilize treatment and mitigate outbreaks. Monoclonal antibody (mAb) based rapid diagnostic tests (RDTs) enable early detection in settings without laboratory capacity. However, the odds of an RDT testing positive are reduced by nearly 90% when the common virulent bacteriophage ICP1 is present. We hypothesize that adding a mAb for the common, and specific, virulent bacteriophage ICP1 as a proxy for V. cholerae to an RDT will increase diagnostic sensitivity when virulent ICP1 phage is present. In this study, we used an in-silico approach to identify immunogenic ICP1 protein targets that were conserved across disparate time periods and locations. Specificity of targets to cholera patients with known ICP1 was determined, and specific targets were used to produce mAbs in a murine model. Candidate mAbs to the head protein demonstrated specificity to ICP1 by Enzyme linked immunosorbent assay (ELISA) and an ICP1 phage neutralization assay. The limit of detection of the final mAb candidate for ICP1 phage particles spiked into cholera stool matrix was 8 × 105 PFU by Western blotting analysis. This mAb will be incorporated into a RDT prototype for evaluation in a future diagnostic study to test the guiding hypothesis behind this study.


Assuntos
Bacteriófagos , Cólera , Vibrio cholerae , Doença Aguda , Animais , Anticorpos Monoclonais/metabolismo , Cólera/diagnóstico , Cólera/epidemiologia , Diarreia , Fezes , Humanos , Camundongos
19.
Emerg Infect Dis ; 28(2): 420-424, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35076001

RESUMO

After a pilot study, we tested 443 cadavers using OraQuick Ebola rapid diagnostic tests during surveillance after the 10th Ebola outbreak in the Democratic Republic of the Congo. No false negative and 2% false-positive results were reported. Quickly returning results and engaging the community enabled timely public health actions.


Assuntos
Ebolavirus , Doença pelo Vírus Ebola , República Democrática do Congo/epidemiologia , Testes Diagnósticos de Rotina , Surtos de Doenças , Doença pelo Vírus Ebola/diagnóstico , Doença pelo Vírus Ebola/epidemiologia , Humanos , Projetos Piloto
20.
Emerg Infect Dis ; 28(1): 244-247, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34726595

RESUMO

We investigated the infectivity of 128 severe acute respiratory disease coronavirus 2-associated deaths and evaluated predictive values of standard diagnostic procedures. Maintained infectivity (20%) did not correlate with viral RNA loads but correlated well with anti-S antibody levels. Sensitivity >90% for antigen-detecting rapid diagnostic tests supports their usefulness for assessment.


Assuntos
COVID-19 , SARS-CoV-2 , Autopsia , Testes Diagnósticos de Rotina , Humanos , Sensibilidade e Especificidade , Carga Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA