RESUMO
BACKGROUND: Compelling evidence shows the association between the relative biological effectiveness (RBE) of carbon-ion radiotherapy (CIRT) and the dose averaged linear energy transfer (LETd). However, the ability to calculate the LETd in commercially available treatment planning systems (TPS) is lacking. PURPOSE: This study aims to develop a method of calculating the LETd of CIRT plans that could be robustly carried out in RayStation (V10B, Raysearch, Sweden). METHODS: The calculation used the fragment spectra in RayStation for the CIRT treatment planning. The dose-weighted averaging procedure was supported by the microdosimetric kinetic model (MKM). The MKM-based pencil beam dose engine (PBA, v4.2) for calculating RBE-weighted doses was reformulated to become a LET-weighted calculating engine. A separate module was then configured to inversely calculate the LETd from the absorbed dose of a plan and the associated fragment spectra. In this study, the ion and energy-specific LET table in the LETd module was further matched with the values decoded from the baseline data of the Syngo TPS (V13C, Siemens, Germany). The LETd distributions of several monoenergetic and modulated beams were calculated and validated against the values derived from the Syngo TPS and the published data. RESULTS: The differences in LETds of the monoenergetic beams between the new method and the traditional method were within 3% in the entrance and Bragg-peak regions. However, a larger difference was observed in the distal region. The results of the modulated beams were in good agreement with the works from the published literature. CONCLUSIONS: The method presented herein reformulates the MKM dose engine in the RayStation TPS to inversely calculate LETds. The robustness and accuracy were demonstrated.
Assuntos
Radioterapia com Íons Pesados , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Transferência Linear de Energia , Eficiência Biológica Relativa , Planejamento da Radioterapia Assistida por Computador/métodos , Carbono , Dosagem Radioterapêutica , Método de Monte CarloRESUMO
BACKGROUND: Clinical data suggest that the relative biological effectiveness (RBE) in proton therapy (PT) varies with linear energy transfer (LET). However, LET calculations are neither standardized nor available in clinical routine. Here, the status of LET calculations among European PT institutions and their comparability are assessed. MATERIALS AND METHODS: Eight European PT institutions used suitable treatment planning systems with their center-specific beam model to create treatment plans in a water phantom covering different field arrangements and fulfilling commonly agreed dose objectives. They employed their locally established LET simulation environments and procedures to determine the corresponding LET distributions. Dose distributions D1.1 and DRBE assuming constant and variable RBE, respectively, and LET were compared among the institutions. Inter-center variability was assessed based on dose- and LET-volume-histogram parameters. RESULTS: Treatment plans from six institutions fulfilled all clinical goals and were eligible for common analysis. D1.1 distributions in the target volume were comparable among PT institutions. However, corresponding LET values varied substantially between institutions for all field arrangements, primarily due to differences in LET averaging technique and considered secondary particle spectra. Consequently, DRBE using non-harmonized LET calculations increased inter-center dose variations substantially compared to D1.1 and significantly in mean dose to the target volume of perpendicular and opposing field arrangements (p < 0.05). Harmonizing LET reporting (dose-averaging, all protons, LET to water or to unit density tissue) reduced the inter-center variability in LET to the order of 10-15% within and outside the target volume for all beam arrangements. Consequentially, inter-institutional variability in DRBE decreased to that observed for D1.1. CONCLUSION: Harmonizing the reported LET among PT centers is feasible and allows for consistent multi-centric analysis and reporting of tumor control and toxicity in view of a variable RBE. It may serve as basis for harmonized variable RBE dose prescription in PT.
Assuntos
Transferência Linear de Energia , Terapia com Prótons , Humanos , Método de Monte Carlo , Prótons , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica RelativaRESUMO
BACKGROUND: Clinically, a constant value of 1.1 is used for the relative biological effectiveness (RBE) of protons, whereas in vitro the RBE has been shown to vary depending on physical dose, tissue type, and linear energy transfer (LET). As the LET increases at the distal end of the proton beam, concerns exist for an elevated RBE in normal tissues. The aim of this study was therefore to investigate the heterogeneity of RBE to brain structures associated with cognition (BSCs) in pediatric suprasellar tumors. MATERIAL AND METHODS: Intensity-modulated proton therapy (IMPT) plans for 10 pediatric craniopharyngioma patients were re-calculated using 11 phenomenological and two plan-based variable RBE models. Based on LET, tissue dependence and number of data points used to fit the models, the three RBE models considered the most relevant for the studied endpoint were selected. Thirty BSCs were investigated in terms of RBE and dose/volume parameters. RESULTS: For a representative patient, the median (range) dose-weighted mean RBE (RBEd) across all BSCs from the plan-based models was among the lowest (1.09 (1.02-1.52) vs. the phenomenological models at 1.21 (0.78-2.24)). Omitting tissue dependency resulted in RBEd at 1.21 (1.04-2.24). Across all patients, the narrower RBE model selection gave median RBEd values from 1.22 to 1.30. CONCLUSION: For all BSCs, there was a systematic model-dependent variation in RBEd, mirroring the uncertainty in biological effects of protons. According to a refined selection of in vitro models, the RBE variation across BSCs was in effect underestimated when using a fixed RBE of 1.1.
Assuntos
Neoplasias Encefálicas , Neoplasias Hipofisárias , Terapia com Prótons , Neoplasias Encefálicas/radioterapia , Criança , Cognição , Humanos , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica RelativaRESUMO
Predicting radiobiological effects is important in different areas of basic or clinical applications using ionizing radiation (IR); for example, towards optimizing radiation protection or radiation therapy protocols. In this case, we utilized as a basis the 'MultiScale Approach (MSA)' model and developed an integrated mathematical radiobiological model (MRM) with several modifications and improvements. Based on this new adaptation of the MSA model, we have predicted cell-specific levels of initial complex DNA damage and cell survival for irradiation with 11Β, 12C, 14Ν, 16Ο, 20Νe, 40Αr, 28Si and 56Fe ions by using only three input parameters (particle's LET and two cell-specific parameters: the cross sectional area of each cell nucleus and its genome size). The model-predicted survival curves are in good agreement with the experimental ones. The particle Relative Biological Effectiveness (RBE) and Oxygen Enhancement Ratio (OER) are also calculated in a very satisfactory way. The proposed integrated MRM model (within current limitations) can be a useful tool for the assessment of radiation biological damage for ions used in hadron-beam radiation therapy or radiation protection purposes.
Assuntos
Dano ao DNA , Modelos Biológicos , Radiobiologia , Sobrevivência Celular/efeitos da radiaçãoRESUMO
(1) Background: Cancer ion therapy is constantly growing thanks to its increased precision and, for heavy ions, its increased biological effectiveness (RBE) with respect to conventional photon therapy. The complex dependence of RBE on many factors demands biophysical modeling. Up to now, only the Local Effect Model (LEM), the Microdosimetric Kinetic Model (MKM), and the "mixed-beam" model are used in clinics. (2) Methods: In this work, the BIANCA biophysical model, after extensive benchmarking in vitro, was applied to develop a database predicting cell survival for different ions, energies, and doses. Following interface with the FLUKA Monte Carlo transport code, for the first time, BIANCA was benchmarked against in vivo data obtained by C-ion or proton irradiation of the rat spinal cord. The latter is a well-established model for CNS (central nervous system) late effects, which, in turn, are the main dose-limiting factors for head-and-neck tumors. Furthermore, these data have been considered to validate the LEM version applied in clinics. (3) Results: Although further benchmarking is desirable, the agreement between simulations and data suggests that BIANCA can predict RBE for C-ion or proton treatment of head-and-neck tumors. In particular, the agreement with proton data may be relevant if the current assumption of a constant proton RBE of 1.1 is revised. (4) Conclusions: This work provides the basis for future benchmarking against patient data, as well as the development of other databases for specific tumor types and/or normal tissues.
Assuntos
Cordoma/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Radioterapia com Íons Pesados , Terapia com Prótons/métodos , Medula Espinal/metabolismo , Animais , Células CHO , Carbono/química , Sobrevivência Celular/efeitos da radiação , Sistema Nervoso Central/efeitos da radiação , Cricetinae , Cricetulus , Bases de Dados Factuais , Humanos , Cinética , Método de Monte Carlo , Radiometria , Ratos , Eficiência Biológica RelativaRESUMO
BACKGROUND: Applying tolerance doses for organs at risk (OAR) from photon therapy introduces uncertainties in proton therapy when assuming a constant relative biological effectiveness (RBE) of 1.1. PURPOSE: This work introduces the novel dirty and clean dose concept, which allows for creating treatment plans with a more photon-like dose response for OAR and, thus, less uncertainties when applying photon-based tolerance doses. METHODS: The concept divides the 1.1-weighted dose distribution into two parts: the clean and the dirty dose. The clean and dirty dose are deposited by protons with a linear energy transfer (LET) below and above a set LET threshold, respectively. For the former, a photon-like dose response is assumed, while for the latter, the RBE might exceed 1.1. To reduce the dirty dose in OAR, a MaxDirtyDose objective was added in treatment plan optimization. It requires setting two parameters: LET threshold and max dirty dose level. A simple geometry consisting of one target volume and one OAR in water was used to study the reduction in dirty dose in the OAR depending on the choice of the two MaxDirtyDose objective parameters during plan optimization. The best performing parameter combinations were used to create multiple dirty dose optimized (DDopt) treatment plans for two cranial patient cases. For each DDopt plan, 1.1-weighted dose, variable RBE-weighted dose using the Wedenberg RBE model and dose-average LETd distributions as well as resulting normal tissue complication probability (NTCP) values were calculated and compared to the reference plan (RefPlan) without MaxDirtyDose objectives. RESULTS: In the water phantom studies, LET thresholds between 1.5 and 2.5 keV/µm yielded the best plans and were subsequently used. For the patient cases, nearly all DDopt plans led to a reduced Wedenberg dose in critical OAR. This reduction resulted from an LET reduction and translated into an NTCP reduction of up to 19 percentage points compared to the RefPlan. The 1.1-weighted dose in the OARs was slightly increased (patient 1: 0.45 Gy(RBE), patient 2: 0.08 Gy(RBE)), but never exceeded clinical tolerance doses. Additionally, slightly increased 1.1-weighted dose in healthy brain tissue was observed (patient 1: 0.81 Gy(RBE), patient 2: 0.53 Gy(RBE)). The variation of NTCP values due to variation of α/ß from 2 to 3 Gy was much smaller for DDopt (2 percentage points (pp)) than for RefPlans (5 pp). CONCLUSIONS: The novel dirty and clean dose concept allows for creating biologically more robust proton treatment plans with a more photon-like dose response. The reduced uncertainties in RBE can, therefore, mitigate uncertainties introduced by using photon-based tolerance doses for OAR.
Assuntos
Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Prótons , Transferência Linear de Energia , Dosagem Radioterapêutica , Eficiência Biológica Relativa , Água , Planejamento da Radioterapia Assistida por Computador/métodosRESUMO
High-linear energy transfer (LET) radiation is a promising alternative to conventional low-LET radiation for therapeutic gain against cancer owing to its ability to induce complex and clustered DNA lesions. However, the development of radiation resistance poses a significant barrier. The potential molecular mechanisms that could confer resistance development are translesion synthesis (TLS), replication gap suppression (RGS) mechanisms, autophagy, epithelial-mesenchymal transition (EMT) activation, release of exosomes, and epigenetic changes. This article will discuss various types of complex clustered DNA damage, their repair mechanisms, mutagenic potential, and the development of radiation resistance strategies. Furthermore, it highlights the importance of careful consideration and patient selection when employing high-LET radiotherapy in clinical settings.
Assuntos
Transferência Linear de Energia , Neoplasias , Tolerância a Radiação , Humanos , Neoplasias/radioterapia , Neoplasias/patologia , Dano ao DNA/efeitos da radiação , Reparo do DNA/efeitos da radiação , AnimaisRESUMO
Purpose: This study develop a novel linear energy transfer (LET) optimization method for intensity-modulated proton therapy (IMPT) with minimum monitor unit (MMU) constraint using the alternating direction method of multipliers (ADMM). Material and methods: The novel LET optimization method (ADMM-LET) was proposed with (1) the dose objective and the LET objective as the optimization objective and (2) the non-convex MMU threshold as a constraint condition. ADMM was used to solve the optimization problem. In the ADMM-LET framework, the optimization process entails iteratively solving the dose sub-problem and the LET sub-problem, simultaneously ensuring compliance with the MMU constraint. Three representative cases, including brain, liver, and prostate cancer, were utilized to evaluate the performance of the proposed method. The dose and LET distributions from ADMM-LET were compared to those obtained using the published iterative convex relaxation (ICR-LET) method. Results: The results demonstrate the superiority of ADMM-LET over ICR-LET in terms of LET distribution while achieving a comparable dose distribution. More specifically, for the brain case, the maximum LET (unit: keV/µm) at the optic nerve decreased from 5.45 (ICR-LET) to 1.97 (ADMM-LET). For the liver case, the mean LET (unit: keV/µm) at the clinical target volume increased from 4.98 (ICR-LET) to 5.50 (ADMM-LET). For the prostate case, the mean LET (unit: keV/µm) at the rectum decreased from 2.65 (ICR-LET) to 2.14 (ADMM-LET). Conclusion: This study establishes ADMM-LET as a new approach for LET optimization with the MMU constraint in IMPT, offering potential improvements in treatment outcomes and biological effects.
RESUMO
Objective. Helium, oxygen, and neon ions in addition to carbon ions will be used for hypofractionated multi-ion therapy to maximize the therapeutic effectiveness of charged-particle therapy. To use new ions in cancer treatments based on the dose-fractionation protocols established in carbon-ion therapy, this study examined the cell-line-specific radioresponse to therapeutic helium-, oxygen-, and neon-ion beams within wide dose ranges.Approach. Response of cells to ions was described by the stochastic microdosimetric kinetic model. First, simulations were made for the irradiation of one-field spread-out Bragg peak beams in water with helium, carbon, oxygen, and neon ions to achieve uniform survival fractions at 37%, 10%, and 1% for human salivary gland tumor (HSG) cells, the reference cell line for the Japanese relative biological effectiveness weighted dose system, within the target region defined at depths from 90 to 150 mm. The HSG cells were then replaced by other cell lines with different radioresponses to evaluate differences in the biological dose distributions of each ion beam with respect to those of carbon-ion beams.Main results. For oxygen- and neon-ion beams, the biological dose distributions within the target region were almost equivalent to those of carbon-ion beams, differing by less than 5% in most cases. In contrast, for helium-ion beams, the biological dose distributions within the target region were largely different from those of carbon-ion beams, more than 10% in several cases.Significance.From the standpoint of tumor control evaluated by the clonogenic cell survival, this study suggests that the dose-fractionation protocols established in carbon-ion therapy could be reasonably applied to oxygen- and neon-ion beams while some modifications in dose prescription would be needed when the protocols are applied to helium-ion beams. This study bridges the gap between carbon-ion therapy and hypofractionated multi-ion therapy.
Assuntos
Carbono , Hélio , Humanos , Neônio/uso terapêutico , Carbono/uso terapêutico , Hélio/uso terapêutico , Oxigênio/uso terapêutico , Íons , Eficiência Biológica RelativaRESUMO
In the next decade, the International Commission on Radiological Protection (ICRP) will issue the next set of general recommendations, for which evaluation of relative biological effectiveness (RBE) for various types of tissue reactions would be needed. ICRP has recently classified diseases of the circulatory system (DCS) as a tissue reaction, but has not recommended RBE for DCS. We therefore evaluated the mean and uncertainty of RBE for DCS by applying a microdosimetric kinetic model specialized for RBE estimation of tissue reactions. For this purpose, we analyzed several RBE data for DCS determined by past animal experiments and evaluated the radius of the subnuclear domain best fit to each experiment as a single free parameter included in the model. Our analysis suggested that RBE for DCS tends to be lower than that for skin reactions, and their difference was borderline significant due to large variances of the evaluated parameters. We also found that RBE for DCS following mono-energetic neutron irradiation of the human body is much lower than that for skin reactions, particularly at the thermal energy and around 1 MeV. This tendency is considered attributable not only to the intrinsic difference of neutron RBE between skin reactions and DCS but also to the difference in the contributions of secondary γ-rays to the total absorbed doses between their target organs. These findings will help determine RBE by ICRP for preventing tissue reactions.
Assuntos
Radiometria , Eficiência Biológica Relativa , Humanos , Animais , Relação Dose-Resposta à Radiação , Pele/efeitos da radiaçãoRESUMO
BACKGROUND AND PURPOSE: Disregarding the increase of relative biological effectiveness (RBE) may raise the risk of acute and late adverse events after proton beam therapy (PBT). This study aims to explore the relationship between variable RBE (above 1.1)-induced normal tissue complication probabilities (NTCP) and patient-specific factors, identify patients at high risk of RBE-induced NTCP increase, and assess risk mitigation by incorporating RBE variability into treatment planning. MATERIALS AND METHODS: We retrospectively analyzed 105 primary brain tumor patients treated with PBT (RBE = 1.1). We calculated differences in estimated NTCP (ΔNTCP) using a variable RBE-weighted dose (DRBE, Wedenberg model) and a constant RBE-weighted dose (DRBE=1.1), across 16 NTCP models. These differences were correlated with patient-specific characteristics. Based on ΔNTCP, patients were classified as high risk (32 %) or low risk (68 %) for adverse events due to RBE-induced NTCP. This classification was compared with alternative classifications based on (a) relevant patient-specific characteristics, (b) DRBE=1.1, and (c) the difference between DRBE and DRBE=1.1 (ΔD), assessing the balanced accuracy. The potential to reduce RBE-induced NTCP through track-end and linear energy transfer (LET) optimization was evaluated in six example patients. RESULTS: Using a variable RBE instead of a constant one resulted in NTCP increases (up to 32 percentage points). Variable-RBE-induced NTCP increases were strongly negatively correlated with the distance between the clinical target volume (CTV) and the organ at risk (OAR) for most side-effects, and positively correlated with CTV volume for certain side-effects. High increases were associated with (a) specific patient factors, particularly the proximity of the CTV to OARs, (b) DRBE=1.1, and (c) ΔD, with a balanced accuracy of 0.88, 0.94, and 0.86, respectively. Optimization of track-ends and LET considerably reduced NTCP values, achieving a mean reduction of 31 % for optimized OARs. CONCLUSION: The risk of variable-RBE-induced NTCP strongly depends on patient-specific factors and the considered side-effect. A small distance between the tumor and OARs notably increases the risk. Integrating biologically-guided objectives into treatment planning can effectively mitigate the risk.
RESUMO
PURPOSE: The use of Monte Carlo (MC) simulations capable of reproducing radiobiological effects of ionising radiation on human cell lines is of great importance, especially for cases involving protons and heavier ion beams. In the latter, huge uncertainties can arise mainly related to the effects of the secondary particles produced in the beam-tissue interaction. This paper reports on a detailed MC study performed using Geant4-based approach on three cancer cell lines, the HTB-177, CRL-5876 and MCF-7, that were previously irradiated with therapeutic proton and carbon ion beams. METHODS: A Geant4-based approach used jointly with analytical calculations has been developed to provide a more realistic estimation of the radiobiological damage produced by proton and carbon beams in tissues, reproducing available data obtained from in vitro cell irradiations. The MC "Hadrontherapy" Geant4 application and the Local Effect Model: LEM I, LEM II and LEM III coupled with the different numerical approaches: RapidRusso (RR) and RapidScholz (RS) were used in the study. RESULTS: Experimental survival curves are compared with those evaluated using the highlighted Geant4 MC-based approach via chi-square statistical analysis, for the combinations of radiobiological models and numerical approaches, as outlined above. CONCLUSION: This study has presented a comparison of the survival data from MC simulations to experimental survival data for three cancer cell lines. An overall best level of agreement was obtained for the HTB-177 cells.
Assuntos
Terapia com Prótons , Prótons , Salicilatos , Humanos , Dosagem Radioterapêutica , Carbono , Planejamento da Radioterapia Assistida por Computador , Método de Monte Carlo , Eficiência Biológica RelativaRESUMO
Background and purpose: Ion beams exhibit an increased relative biological effectiveness (RBE) with respect to photons. This study determined the RBE of oxygen ion beams as a function of linear energy transfer (LET) and dose in the rat spinal cord. Materials and methods: The spinal cord of rats was irradiated at four different positions of a 6 cm spread-out Bragg-peak (LET: 26, 66, 98 and 141 keV/µm) using increasing levels of single and split oxygen ion doses. Dose-response curves were established for the endpoint paresis grade II and based on ED50 (dose at 50 % effect probability), the RBE was determined and compared to model predictions. Results: When LET increased from 26 to 98 keV/µm, ED50 decreased from 17.2 ± 0.3 Gy to 13.5 ± 0.4 Gy for single and from 21.7 ± 0.4 Gy to 15.5 ± 0.5 Gy for split doses, however, at 141 keV/µm, ED50 rose again to 15.8 ± 0.4 Gy and 17.2 ± 0.4 Gy, respectively. As a result, the RBE increased from 1.43 ± 0.05 to 1.82 ± 0.08 (single dose) and from 1.58 ± 0.04 to 2.21 ± 0.08 (split dose), respectively, before declining again to 1.56 ± 0.06 for single and 1.99 ± 0.06 for split doses at the highest LET. Deviations from RBE-predictions were model-dependent. Conclusion: This study established first RBE data for the late reacting central nervous system after single and split doses of oxygen ions. The data was used to validate the RBE-dependence on LET and dose of three RBE-models. This study extends the existing data base for protons, helium and carbon ions and provides important information for future patient treatments with oxygen ions.
RESUMO
PURPOSE: Development of a model characterizing risk variation with RBE to investigate how the incidence risk for all solid cancers combined varies with higher neutron RBEs and different organ dose types. MATERIAL AND METHODS: The model is based on RERF data with separate neutron and gamma dose information. RESULTS: For both additive and multiplicative linear excess risks per unit organ averaged dose, a reduction of 50% in the risk coefficient per weighted dose arises when a neutron RBE of 110 is used instead of 10. Considering risk per unit liver dose, this reduction occurs for an RBE of 130 and for risks per unit colon dose for an RBE of 190. The change in the shape of the dose response curve when using higher neutron RBEs is evaluated. The curvature changed and became significantly negative for males at an RBE of 140 for colon dose, 100 for liver dose and 80 for organ averaged dose. For females this is the case at an RBE of 110, 80 and 60, respectively. CONCLUSIONS: Uncertainties in neutron RBE values should be considered when radiation risks and the shape of dose responses are deduced from cancer risk data from the atomic bomb survivors.
Assuntos
Neoplasias Induzidas por Radiação , Masculino , Feminino , Humanos , Neoplasias Induzidas por Radiação/etiologia , Neoplasias Induzidas por Radiação/epidemiologia , Sobreviventes de Bombas Atômicas , População do Leste Asiático , Eficiência Biológica Relativa , NêutronsRESUMO
The pBR322 plasmid DNA was irradiated with 35 MeV electrons, 228 MeV protons and 300 kVp X-rays to quantify DNA damage and make comparisons of DNA damage between radiation modalities. Plasmid was irradiated in a medium containing hydroxyl radical scavengers in varying concentrations. This altered the amount of indirect hydroxyl-mediated DNA damage, to create an environment that is more closely associated with a biological cell. We show that increasing hydroxyl scavenger concentration significantly reduced post-irradiation DNA damage to pBR322 plasmid DNA consistently and equally with three radiation modalities. At low scavenging capacities, irradiation with both 35 MeV electrons and 228 MeV protons resulted in increased DNA damage per dose compared with 300 kVp X-rays. We quantify both single-strand break (SSB) and double-strand break (DSB) induction between the modalities as a ratio of yields relative to X-rays, referred to as relative biological effectiveness (RBE). RBESSB values of 1.16 ± 0.15 and 1.18 ± 0.08 were calculated for protons and electrons, respectively, in a low hydroxyl scavenging environment containing 1 mM Tris-HCl for SSB induction. In higher hydroxyl scavenging capacity environments (above 1.1 × 106 s-1), no significant differences in DNA damage induction were found between radiation modalities when using SSB induction as a measure of RBE. Considering DSB induction, significant differences were only found between X-rays and 35 MeV electrons, with an RBEDSB of 1.72 ± 0.91 for 35 MeV electrons, indicating that electrons result in significantly more SSBs and DSBs per unit of dose than 300 kVp X-rays.
RESUMO
INTRODUCTION: Our objective was to compare [64Cu]Cu-NOTA-panitumumab F(ab')2 and [177Lu]Lu-NOTA-panitumumab F(ab')2 radioimmunotherapy (RIT) agents for decreasing the clonogenic survival fraction (SF) in vitro of EGFR-positive human pancreatic ductal adenocarcinoma (PDAC) cell lines and estimate the relative biological effectiveness (RBE) vs. γ-radiation (XRT). METHODS: EGFR-positive PDAC cell lines (AsPC-1, PANC-1, MIAPaCa-2, Capan-1) and EGFR-knockout PANC-1 EGFR KO cells were treated in vitro for 18 h with (0-19.65 MBq; 72 nmols/L) of [64Cu]Cu-NOTA-panitumumab F(ab')2 or [177Lu]Lu-NOTA-panitumumab F(ab')2 or XRT (0-8 Gy) followed by clonogenic assay. The SF was determined after culturing single treated cells for 14 d. Cell fractionation studies were performed for cells incubated with 1 MBq (72 nmols/L) of [64Cu]Cu-NOTA-panitumumab F(ab')2 or [177Lu]Lu-NOTA-panitumumab F(ab')2 for 1, 4, or 24 h to estimate the time-integrated activity (Ã) on the cell surface, cytoplasm, nucleus and medium. Radiation absorbed doses in the nucleus were calculated by multiplying à by S-factors calculated by Monte Carlo N Particle (MCNP) modeling using monolayer cell culture geometry. The SF of PDAC cells was plotted vs. dose and fitted to a linear quadratic model to estimate the dose required to decrease the SF to 0.1 (D10). The D10 for RIT agents were compared to XRT to estimate the RBE. DNA double-strand breaks (DSBs) caused by [64Cu]Cu-NOTA-panitumumab F(ab')2 or [177Lu]Lu-NOTA-panitumumab F(ab')2 continuous exposure for 5 h or 20 h were probed by immunofluorescence for γ-H2AX. Relative EGFR expression of PDAC cells was assessed by flow cytometry (scored + to +++) and cell doubling times for untreated cells were determined. RESULTS: The D10 for [64Cu]Cu-NOTA-panitumumab F(ab')2 ranged from 9.1 Gy (PANC-1) to 39.9 Gy (Capan-1). The D10 for [177Lu]Lu-NOTA-panitumumab F(ab')2 ranged from 11.7 Gy (AsPC-1) to 170.8 Gy (Capan-1). The D10 for XRT ranged from 2.5 Gy (Capan-1) to 6.7 Gy (PANC-1 EGFR KO). D10 values were not correlated with EGFR expression over a relatively narrow range (++ to +++) or with cell doubling times. Based on D10 values, PANC-1 EGFR KO cells were 1.6-fold less sensitive than PANC-1 cells to [64Cu]Cu-NOTA-panitumumab F(ab')2 and 1.9-fold less sensitive to [177Lu]Lu-NOTA-panitumumab F(ab')2. The RBE for [64Cu]Cu-NOTA-panitumumab F(ab')2 ranged from 0.06 for Capan-1 cells to 0.45 for PANC-1 cells. The RBE for [177Lu]Lu-NOTA-panitumumab F(ab')2 ranged from 0.015 for Capan-1 cells to 0.28 for AsPC-1 cells. DNA DSBs were detected in PDAC cells exposed to [64Cu]Cu-NOTA-panitumumab F(ab')2 or [177Lu]Lu-NOTA-panitumumab F(ab')2 but were not correlated with the SF of the cells. CONCLUSIONS: We conclude that at the same dose delivered to the cell nucleus [64Cu]Cu-NOTA-panitumumab F(ab')2 and [177Lu]Lu-NOTA-panitumumab F(ab')2 were less radiobiologically effective than XRT for decreasing the SF of human PDAC cells, but [64Cu]Cu-NOTA-panitumumab F(ab')2 was more cytotoxic than [177Lu]Lu-NOTA-panitumumab F(ab')2 except for AsPC-1 cells which were more sensitive to [177Lu]Lu-NOTA-panitumumab F(ab')2. ADVANCES IN KNOWLEDGE AND IMPLICATIONS FOR PATIENT CARE: This study demonstrates that higher radiation doses may be required for RIT than XRT to achieve radiobiologically equivalent effects when used to treat PDAC.
Assuntos
Adenocarcinoma , Receptores ErbB , Humanos , Panitumumabe , Eficiência Biológica Relativa , Receptores ErbB/metabolismo , DNA , Linhagem Celular Tumoral , Neoplasias PancreáticasRESUMO
BACKGROUND: To evaluate the clinical relative biological effectiveness (RBE) of carbon-ion radiotherapy (C-ion RT) for prostate cancer. METHODS: The records of 262 patients with low-risk prostate cancer (median age, 65 [47-80] years) treated with C-ion RT at QST Hospital, National Institutes for Quantum Science and Technology in Japan during 2000-2018 were reviewed retrospectively. Four different protocol outcomes and prostate-specific antigen (PSA) responses were evaluated. The median follow-up was 8.4 years. The Kaplan-Meier method was used to estimate the biochemical or clinical failure-free rate (BCFFR). Clinical RBE was calculated using the tumor control probability model. RESULTS: The 5-, 7-, and 10-year BCFFRs were 91.7%, 83.8%, and 73.2%, respectively. The 10-year BCFFRs of patients who received C-ion RT at 66 Gy (RBE) in 20 fractions, 63 Gy (RBE) in 20 fractions, and 57.6 Gy (RBE) in 16 fractions were 81.4%, 70.9%, and 68.9%, respectively. The PSA level and density during follow-up were better in the patients treated with the lower fraction size. A higher PSA nadir and shorter time to PSA nadir were risk factors for biochemical or clinical failure by multivariate Cox regression. The tumor control probability analysis showed that the estimated clinical RBE values to achieve an 80% BCFFR at 10 years for 20, 16, and 12 fractions were 2.19 (2.18-2.24), 2.16 (2.14-2.23), and 2.12 (2.09-2.21), respectively. CONCLUSIONS: Using clinical data from low-risk prostate cancer patients, we showed the clinical RBE of C-ion RT decreased with increasing dose per fraction.
Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Idoso , Estudos Retrospectivos , Eficiência Biológica Relativa , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , CarbonoRESUMO
Background: Heavy ion radiotherapy, such as carbon ion radiotherapy (CIRT), has multiple advantages over conventional photon therapy. Cisplatin, as a classic anti-tumor drugs, has been tested and discovered as a photon radiosensitizer in several cell lines, including head and neck squamous cell carcinoma (HNSCC). Hence, the aim of our study is to evaluate whether cisplatin can sensitize CIRT towards HNSCC cell lines in vitro. Methods: Human nasopharyngeal carcinoma cell line CNE-2, human tongue squamous carcinoma cell line TCA 8113 and human hypopharynx squamous carcinoma cell line FADU were all irradiated with photon beam of 2, 4, 6, 8 Gy (physical dose) and carbon ion beam of 1, 2, 3, 4 Gy (physical dose) and treated with cisplatin. Cell survival was assessed by clonogenic survival assay. Results: CIRT showed significantly stronger cytotoxic effect than standard photon radiotherapy. The relative biological effectiveness (RBE) of carbon ion beam at 10% survival ( R B E 10 ) was calculated 3.07 for CNE-2, 2.33 for TCA 8113 and 2.36 for FADU. Chemoradiotherapy (both photon radiotherapy and CIRT) was more effective than radiotherapy alone. In vitro sensitizer enhancement ratios (SERs) of cisplatin in CNE-2, TCA 8113 and FA DU cell lines after photon irradiation were 1.33, 1.14 and 1.21, while after carbon ion irradiation were 1.02, 1.00 and 0.96, showed that cisplatin sensitized photon irradiation but showed no sensitization effect in carbon ion irradiation in all tested cell lines. Conclusions: In conclusion, high linear energy transfer (LET) CIRT was more effective than photon irradiation to prevent the proliferation of HNSCC cell lines. Additional treatment with cisplatin could sensitize photon irradiation but showed no effect on carbon ion irradiation.
RESUMO
This study aimed to quantify the relative biological effectiveness (RBE) for epithermal neutron beam contaminated with fast neutrons in the accelerator-based boron neutron capture therapy (BNCT) system coupled to a solid-state lithium target. The experiments were performed in National Cancer Center Hospital (NCCH), Tokyo, Japan. Neutron irradiation with the system provided by Cancer Intelligence Care Systems (CICS), Inc. was performed. X-ray irradiation, which was assigned as the reference group, was also performed using a medical linear accelerator (LINAC) equipped in NCCH. The four cell lines (SAS, SCCVII, U87-MG and NB1RGB) were utilized to quantify RBE value for the neutron beam. Before both of those irradiations, all cells were collected and dispensed into vials. The doses of 10% cell surviving fraction (SF) (D10) were calculated by LQ model fitting. All cell experiments were conducted in triplicate at least. Because the system provides not only neutrons, but gamma-rays, the contribution from the gamma-rays to the survival fraction were subtracted in this study. D10 value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was 4.26, 4.08, 5.81 and 2.72 Gy, respectively, while that acquired by the X-ray irradiation was 6.34, 7.21, 7.12 and 5.49 Gy, respectively. Comparison of both of the D10 values, RBE value of SAS, SCCVII, U87-MG and NB1RGB for the neutron beam was calculated as 1.7, 2.2, 1.3 and 2.5, respectively, and the average RBE value was 1.9. This study investigated RBE of the epithermal neutron beam contaminated with fast neutrons in the accelerator-based BNCT system coupled to a solid-state lithium target.
Assuntos
Terapia por Captura de Nêutron de Boro , Nêutrons Rápidos , Lítio , Nêutrons , Aceleradores de Partículas , Eficiência Biológica RelativaRESUMO
Recently, a number of clinical studies have explored links between possible Relative Biological Effectiveness (RBE) elevations and patient toxicities and/or image changes following proton therapy. Our objective was to perform a systematic review of such studies. We applied a "Problem [RBE], Intervention [Protons], Population [Patients], Outcome [Side effect]" search strategy to the PubMed database. From our search, we retrieved studies which: (a) performed novel voxel-wise analyses of patient effects versus physical dose and LET (n = 13), and (b) compared image changes between proton and photon cohorts with regard to proton RBE (n = 9). For each retrieved study, we extracted data regarding: primary tumour type; size of patient cohort; type of image change studied; image-registration method (deformable or rigid); LET calculation method, and statistical methodology. We compared and contrasted their methods in order to discuss the weight of clinical evidence for variable proton RBE. We concluded that clinical evidence for variable proton RBE remains statistically weak at present. Our principal recommendation is that proton centres and clinical trial teams collaborate to standardize follow-up protocols and statistical analysis methods, so that larger patient cohorts can ultimately be considered for RBE analyses.