Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Eur Arch Otorhinolaryngol ; 281(3): 1215-1220, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37773530

RESUMO

OBJECTIVES: The influence of cochlear morphology and electrode array design on scalar position and dislocation rates is of great interest in CI surgery. The aim of this study is to evaluate scalar position and specific points of dislocation in relation to cochlear morphology in patients implanted with a new slim perimodiolar electrode array. MATERIALS AND METHODS: Patients were implanted using the slim modiolar electrode array (= SMA) (= 532/632 electrode array of Cochlear™). Postoperative imaging was performed via cone beam computed tomography (CBCT) and the scans were analyzed regarding cochlear morphology (distances A and B and cochlear height), scalar location of the electrode array, basal insertion depth and apical insertion angle. Furthermore, electrode array design and surgical protocols were evaluated. RESULTS: 81 ears implanted with the SMA were retrospectively included. We evaluated 3 electrode array tip fold over intraoperatively via X-ray imaging and performed revision during the same surgery. The CBCT scans showed 76 initial scala tympani (ST) insertions without dislocation. Two ears showed a dislocated array, one at 77° and the other at 163°. Three arrays were inserted into scala vestibuli (SV) via cochleostomy. These patients showed no signs of obliteration. Cochlear morphology showed no influence on angular insertion depth and scalar position. CONCLUSIONS: The SMA showed a very low rate of scalar dislocations due to its slim electrode array design (2.7%). We could find a learning curve regarding the handling and the risk of dislocation and tip fold over with this electrode array. The rate of intraoperative tip fold over detection via X-ray imaging was 3.7%. Therefore, we highly recommend X-ray imaging and transimpedance matrix measurements within the surgery protocol. Scala vestibuli insertions happened in patients with cochleostomy only. We could identify two specific points of dislocation depending on electrode array design.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Cóclea/anatomia & histologia , Rampa do Tímpano/cirurgia , Eletrodos Implantados
2.
HNO ; 72(2): 113-117, 2024 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-37845537

RESUMO

Due to a technical defect or a medical indication, it may be necessary to explant a cochlear implant. This case report shows that there is the risk of encountering a nonremovable electrode array-as described here from the scala tympani-during cochlear reimplantation. In the present case, insertion of a second electrode array into the free and nonobstructed scala vestibuli was successful. Nonetheless, the indication for reimplantation must be carefully considered, especially in patients with tolerable limitations with little or no loss of speech understanding. Furthermore, surgery should not be performed solely because an implant upgrade is desired.


Assuntos
Implante Coclear , Implantes Cocleares , Humanos , Cóclea/cirurgia , Implante Coclear/efeitos adversos , Implantes Cocleares/efeitos adversos , Rampa do Tímpano/cirurgia , Reimplante/efeitos adversos
3.
HNO ; 72(Suppl 1): 63-65, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37943372

RESUMO

Due to a technical defect or a medical indication, it may be necessary to explant a cochlear implant. This case report shows that there is the risk of encountering a nonremovable electrode array-as described here from the scala tympani-during cochlear reimplantation. In the present case, insertion of a second electrode array into the free and nonobstructed scala vestibuli was successful. Nonetheless, the indication for reimplantation must be carefully considered, especially in patients with tolerable limitations with little or no loss of speech understanding. Furthermore, surgery should not be performed solely because an implant upgrade is desired.


Assuntos
Implante Coclear , Reimplante , Humanos , Cóclea/cirurgia , Implante Coclear/efeitos adversos , Reimplante/efeitos adversos , Rampa do Tímpano/cirurgia
4.
Eur Arch Otorhinolaryngol ; 279(9): 4257-4267, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34778920

RESUMO

PURPOSE: The aim of this study is to examine the scalar dislocation rate in straight and perimodiolar electrode arrays in relation to cochlear morphology. Furthermore, we aim to analyze the specific dislocation point of electrode arrays depending on their design and shape and to correlate these results to postoperative speech perception. METHODS: We conducted a comparative analysis of patients (ears: n = 495) implanted between 2013 and 2018 with inserted perimodiolar or straight electrode arrays from Cochlear™ or MED-EL. CBCT (cone beam computed tomography) was used to determine electrode array position (scalar insertion, intra-cochlear dislocation, point of dislocation and angular insertion depth). Furthermore, cochlear morphology was measured. The postoperative speech discrimination was compared regarding electrode array dislocation, primary scalar insertion and angular insertion depth. RESULTS: The electrode array with the highest rate of primary SV insertions was the CA; the electrode array with the highest rate of dislocations out of ST was the FlexSoft. We did not find significantly higher dislocation rates in cochleostomy-inserted arrays. The angle of dislocation was electrode array design-specific. A multivariate nonparametric analysis revealed that the dislocation of the electrode array has no significant influence on postoperative speech perception. Nevertheless, increasing angular insertion depth significantly reduced postoperative speech perception for monosyllables. CONCLUSION: This study demonstrates the significant influence of electrode array design on scalar location, dislocation and the angle of dislocation itself. Straight and perimodiolar electrode arrays differ from each other regarding both the rate and place of dislocation. Insertion via cochleostomy does not lead to increased dislocation rates in any of the included electrode arrays. Furthermore, speech perception is significantly negatively influenced by angular insertion depth.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Cóclea/cirurgia , Implante Coclear/efeitos adversos , Implante Coclear/métodos , Implantes Cocleares/efeitos adversos , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos
5.
Eur Arch Otorhinolaryngol ; 279(10): 4853-4859, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35226182

RESUMO

OBJECTIVE: Due to increasing indication for cochlear implantation (CI), reimplantation and technical upgrades their consequences are a special focus in CI surgery research. The aim of this study is to examine the indication and influences on both morphological position of the electrode array and audiological outcome following reimplantation. DESIGN: This is a retrospective analysis of adult CI patients reimplanted between 2004 and 2019. We evaluated the scalar position in pre- and postoperative cone beam computed tomography (CBCT) after CI and reimplantation and examined the indication for and the audiological outcome following reimplantation. RESULTS: The reimplanted patients showed stable and comparable audiological results for monosyllables and numbers for best fitted situation before and following reimplantation. Technical upgrades did not result in a significant improvement of speech perception. CBCT scans of reimplanted ears did not show significant increased rates of scalar dislocation or partial insertion. CONCLUSION: Even with a technical upgrade, reimplantation does not improve speech perception outcome in CI patients. Therefore, the indication to reimplant should be approved critically. Reimplantation does not lead to a significantly increased risk for partial insertion, scalar dislocation or diminished electrode array insertion angle.


Assuntos
Implante Coclear , Implantes Cocleares , Percepção da Fala , Adulto , Implante Coclear/métodos , Falha de Equipamento , Humanos , Reoperação/métodos , Reimplante , Estudos Retrospectivos
6.
Eur Arch Otorhinolaryngol ; 278(10): 3707-3714, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33090276

RESUMO

OBJECTIVE: The aim of this study is to examine electrode array coverage, scalar position and dislocation rate in straight electrode arrays with special focus on a new electrode array with 26 mm in lengths. STUDY DESIGN: Retrospective study. SETTING: Tertiary academic center. PATIENTS: 201 ears implanted between 2013 and 2019. MAIN OUTCOME MEASURES: We conducted a comparative analysis of patients implanted with lateral wall electrode arrays of different lengths (F24 = MED-EL Flex24, F26 = MED-EL Flex26, F28 = MED-EL Flex28 and F31.5 = MED-EL FlexSoft). Cone beam computed tomography was used to determine electrode array position (scala tympani (ST) versus scala vestibuli (SV), intracochlear dislocation, position of dislocation and insertion angle). RESULTS: Study groups show no significant differences regarding cochlear size which excludes influences by cochlear morphology. As expected, the F24 showed significant shorter insertion angles compared to the longer electrode arrays. The F26 electrode array showed no signs of dislocation or SV insertion. The electrode array with the highest rate of ST dislocations was the F31.5 (26.3%). The electrode array with the highest rates of SV insertions was the F28 (5.75%). Most of the included electrode arrays dislocate between 320° and 360° (mean: 346.4°; range from 166° to 502°). CONCLUSION: The shorter F24 and the new straight electrode array F26 show less or no signs of scalar dislocation, neither for round window nor for cochleostomy insertion than the longer F28 and the F31.5 array. As expected, the cochlear coverage is increasing with length of the electrode array itself but with growing risk for scalar dislocation and with the highest rates of dislocation for the longest electrode array F31.5. Position of intracochlear dislocation is in the apical cochlear part in the included lateral wall electrode arrays.


Assuntos
Implante Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagem , Cóclea/cirurgia , Eletrodos Implantados , Humanos , Estudos Retrospectivos , Rampa do Tímpano/cirurgia
7.
Front Surg ; 8: 695728, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34307444

RESUMO

Background: As an advanced surgical technique to reduce trauma to the inner ear, robot-assisted electrode array (EA) insertion has been applied in adult cochlear implantation (CI) and was approved as a safe surgical procedure that could result in better outcomes. As the mastoid and temporal bones are generally smaller in children, which would increase the difficulty for robot-assisted manipulation, the clinical application of these systems for CI in children has not been reported. Given that the pediatric candidate is the main population, we aim to investigate the safety and reliability of robot-assisted techniques in pediatric cochlear implantation. Methods: Retrospective cohort study at a referral center in Shanghai including all patients of simultaneous bilateral CI with robotic assistance on one side (RobOtol® system, Collin ORL, Bagneux, France), and manual insertion on the other (same brand of EA and CI in both side), from December 2019 to June 2020. The surgical outcomes, radiological measurements (EA positioning, EA insertion depth, mastoidectomy size), and audiological outcomes (Behavior pure-tone audiometry) were evaluated. Results: Five infants (17.8 ± 13.5 months, ranging from 10 to 42 months) and an adult (39 years old) were enrolled in this study. Both perimodiolar and lateral wall EAs were included. The robot-assisted EA insertion was successfully performed in all cases, although the surgical zone in infants was about half the size in adults, and no difference was observed in mastoidectomy size between robot-assisted and manual insertion sides (p = 0.219). The insertion depths of EA with two techniques were similar (P = 0.583). The robot-assisted technique showed no scalar deviation, but scalar deviation occurred for one manually inserted pre-curved EA (16%). Early auditory performance was similar to both techniques. Conclusion: Robot-assisted technique for EA insertion is approved to be used safely and reliably in children, which is possible and potential for better scalar positioning and might improve long-term auditory outcome. Standard mastoidectomy size was enough for robot-assisted technique. This first study marks the arrival of the era of robotic CI for all ages.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA