Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Arch Orthop Trauma Surg ; 143(1): 247-254, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34232348

RESUMO

PURPOSE: Comminuted inferior patellar pole fractures are challenging injuries and require effective treatment due to the extension mechanism of the knee. This study aims to evaluate the outcome of above fractures treated with a modified technique of cerclage-wire-augmented separate vertical wiring (SVW) with cerclage wiring passed through the proximal patella. METHODS: Retrospective analysis (1/2017-1/2020) were performed for patients that were treated with three SVWs through the posterior margin of proximal fragment and directly to the anterosuperior border of patella, combined with a cerclage wiring passed through the proximal patella. Patients who experienced comminuted inferior patellar pole fractures within 3 weeks were included, and the outcome was evaluated radiologically and clinically by Bostman score after a minimum of 12 months following surgery. Further evaluation included the operation time and complication rate. RESULTS: A total of 20 patients (10 males, 10 females) with a mean age of 54 ± 14.5 years (26-83 years) and a follow-up of 18.9 ± 6.6 months (12-36 months) were evaluated. The average operation time was 45.7 ± 8.8 min (30-60 min). At final follow-up, the average range of motion was 131.3° ± 3.5° (125°-135°), and the mean Bostman score was 29.4 ± 0.7 points (28-30) and graded excellent in all cases. Two patients experienced occasional giving way of the knee. Radiologically no loss of reduction, implant breakage, nonunion or skin irritation was observed. CONCLUSIONS: The cerclage-wire-augmented SVW with cerclage wiring passed through the proximal patella appears to be a safe and simple technique which can effectively treat the comminuted inferior patellar pole fractures.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Patela/cirurgia , Patela/lesões , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos , Fios Ortopédicos , Fraturas Cominutivas/cirurgia , Resultado do Tratamento
2.
Arch Orthop Trauma Surg ; 138(2): 195-202, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29058078

RESUMO

INTRODUCTION: We present the surgical technique of rim-plate-augmented separate vertical wiring for comminuted inferior pole fracture of the patella and report the clinical outcomes. MATERIALS AND METHODS: Between July 2013 and January 2016, 13 patients (7 male and 6 female) who were diagnosed with comminuted inferior pole fracture of the patella in preoperative computed tomography and underwent a minimum of 1 year of follow-up were enrolled in this study. Mean patient age was 57.7 years (range 28-72 years). All patients underwent open reduction and internal fixation by rim-plate-augmented separate vertical wiring. Bony union, complications, range of motion and Bostman score were the clinical outcomes. RESULTS: Bony union was achieved in all cases at an average of 10 weeks after surgery (range 8-12). There was no loss of reduction and fixative failure during follow-up. The average range of motion was 127° (range 120°-130°). The mean Bostman score at last follow-up was 29.6 points (range 27-30) and graded excellent in 12 patients. CONCLUSION: Rim-plate-augmented separate vertical wiring demonstrated secure fixation and favorable clinical outcomes. This study provides evidence for its effectiveness as a fixation method for treating displaced, comminuted inferior pole fracture of the patella.


Assuntos
Fios Ortopédicos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Patela/lesões , Patela/cirurgia , Adulto , Idoso , Feminino , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem
3.
J Orthop Surg Res ; 18(1): 176, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36890520

RESUMO

BACKGROUND: The fixation of inferior pole fractures of the patella (IPFPs) is still a great challenge for surgeons. MATERIALS AND METHODS: We introduced a new fixation method for IPFP fixation, that is, separate vertical wiring plus bilateral anchor girdle suturing fixation (SVW-BSAG). Three finite element models including the anterior tension band wiring (ATBW) model, separate vertical wiring (SVW) model and SVW-BSAG model, were built to evaluate the fixation strength of different fixation methods. A total of 41 consecutive patients with IPFP injury were enrolled in this retrospective study, including 23 patients in the ATBW group and 18 patients in the SVW-BSAG group. The operation time, radiation exposure, full weight-bearing time, Bostman score, extension lag versus contralateral healthy leg, Insall-Salvati ratio, and radiograph outcomes were employed to assess and compare the ATBW group and SVW-BSAG group. RESULTS: The finite element analysis confirmed that the SVW-BSAG fixation method was as reliable as the ATBW fixation method in terms of fixed strength. Through retrospective analysis, we found that there was no significant difference between the SVW-BSAG and ATBW groups in age, sex, BMI, fracture side, fracture type, or follow-up time. There were no significant differences between the two groups in the Insall-Salvati ratio, 6-month Bostman score, and fixation failure. Compared with the ATBW group, the SVW-BSAG group showed advantages in intraoperative radiation exposure, full weight-bearing time, and extension lag versus the contralateral healthy leg. CONCLUSION: The finite element analysis and clinical results showed that SVW-BSAG fixation methods are a reliable and valuable for IPFP treatment.


Assuntos
Fraturas Ósseas , Traumatismos do Joelho , Humanos , Estudos Retrospectivos , Patela/diagnóstico por imagem , Patela/cirurgia , Patela/lesões , Fios Ortopédicos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas/métodos
4.
Injury ; 2023 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-36964037

RESUMO

PURPOSE: Comminuted inferior patellar pole fractures are challenging injuries and require adequate treatment due to the extension mechanism of the knee. METHODS: A modified separate vertical fixation by wires and Titanium cables was established according to a finite element biomechanical study. Between September 2018 and May 2021, 18 patients with inferior pole fractures of the patella were retrospectively enrolled in this study. RESULTS: The results of the finite element analysis showed the concentration of stress in the intermediate vertical wire and the cerclage wire. As a partial replacement for steel wires, Titanium cables provide less concentration of stress on the vertical wire (489.4 MPa vs 441.2 Mpa) and less cutting force on the bone (75.87 Mpa vs 53.27), which reduces the possibility of internal fixation failure and improves the stability of internal fixation. In the clinic study, No patients experienced non-union of the fracture, loss of fracture repositioning, malunion of wounds, or wire breakage. At the last follow-up, the average range of motion was 134.7°±11.2°, and the Lysholm Score was 90.7 ± 3.9. CONCLUSIONS: The separate vertical fixation by wires and titanium cables is an effective fixation method for treating displaced, comminuted inferior pole fractures, which attributes to early exercise and better function.

5.
Rev.chil.ortop.traumatol. ; 63(1): 1-8, apr.2022. ilus
Artigo em Espanhol | LILACS | ID: biblio-1435398

RESUMO

INTRODUCCIÓN Las fracturas conminutas del polo distal de la patela representan un desafío para el cirujano de rodilla, pues no existe un tratamiento estándar que permita una rehabilitación acelerada. Recientemente se han descrito la osteosíntesis y la reinserción del polo distal utilizando asas de alambre verticales. MATERIALES Y MÉTODOS Presentamos dos casos de fractura conminuta del polo distal de la patela resueltos con asas de alambre verticales y modificaciones de esta técnica. RESULTADOS Se realizó osteosíntesis del polo distal de la patela, y se logró una reducción radiográfica satisfactoria, lo que permitió una rehabilitación acelerada, con un rango de movilidad progresivo a tolerancia desde el día siguiente tras la cirugía. Los pacientes lograron recuperar el rango de movimiento completo a los dos y tres meses de operados, evolucionaron satisfactoriamente, sin complicaciones relacionadas a esta técnica y sus variaciones, y recibieron el alta médica tras cuatro meses de la reducción y osteosíntesis. DISCUSIÓN Las técnicas tradicionales para el manejo de fracturas del polo distal implican consideraciones especiales en la rehabilitación y complicaciones asociadas. Se utilizó la técnica de asas de alambres verticales en dos pacientes: en uno de ellos, el procedimiento fue complementado con sutura tipo Krackow; y, en el otro, con una placa para minifragmentos, lo que permitió una rehabilitación acelerada y retorno precoz a sus actividades laborales. CONCLUSIÓN El uso de asas de alambre vertical aparece como una técnica segura, que permite una rehabilitación acelerada y un reintegro laboral precoz.


INTRODUCTION Comminuted fractures of the distal pole of the patella represent a challenge for the knee surgeon, as there is no standard treatment that enables accelerated rehabilitation. Osteosynthesis and reattachment of the distal pole using vertical wire loops has recently been described. MATERIALS AND METHODS We herein present two cases of omminuted fracture of the distal pole of the patella resolved with vertical wire loops and modifications of this technique. RESULTS Osteosynthesis of the distal pole of the patella was performed, achieving a satisfactory radiographic reduction and enabling accelerated rehabilitation, with a progressive range of motion the day after the surgery. The patients achieved full range of motion two and three months after surgery. They progressed satisfactorily, without complications related to this technique and its variations, and were discharged four months after the reduction and osteosynthesis. DISCUSSION The traditional techniques for the management of distal pole fractures involve special considerations regarding rehabilitation and associated complications. The vertical wire loop technique was used in two patients: in one of them, it was supplemented with a Krackow suture; and, in the other, with a mini-fragment plate, which enabled accelerated rehabilitation and early return to work. CONCLUSION The use of vertical wire loops appears to be a safe technique, which enables accelerated rehabilitation and early return to work.


Assuntos
Humanos , Masculino , Idoso , Patela/cirurgia , Fixação Interna de Fraturas/métodos , Fios Ortopédicos
6.
Injury ; 46(12): 2512-5, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26482481

RESUMO

BACKGROUND: We present the surgical technique of separate vertical wiring for displaced inferior pole fractures of the patella combined with Krachow suture and report the surgical outcomes. MATERIALS AND METHODS: Between September 2007 to May 2012, 11 consecutive patients (mean age, 54.6 years) with inferior pole fractures of the patella (AO/OTA 34-A1) were retrospectively enrolled in this study. Through longitudinal incision, all patients underwent open reduction and internal fixation by separate vertical wiring combined with Krackow suture. The range of motion, loss of fixation, and Bostman score were primary outcome measures. RESULTS: The union time was 10 weeks after surgery on average (range: 8-12). No patient had nonunion, loss of reduction and wire breakage. There was no case of wound problem and irritation from the implant. At final follow-up, the average range of motion arc was 129.4° (range: 120-140). The mean Bostman score at last follow-up was 29.6 points (range: 28-30) and graded excellent in all cases. CONCLUSION: Separate vertical wiring combined with Krackow suture for inferior pole fractures of the patella is a useful technique that is easy to perform and can provide stable fixation with excellent results in knee function.


Assuntos
Fixação Interna de Fraturas , Consolidação da Fratura , Fraturas Ósseas/cirurgia , Fraturas Cominutivas/cirurgia , Articulação do Joelho/cirurgia , Patela/cirurgia , Adulto , Idoso , Fios Ortopédicos , Feminino , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Fraturas Cominutivas/diagnóstico por imagem , Fraturas Cominutivas/fisiopatologia , Humanos , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Patela/diagnóstico por imagem , Patela/lesões , Guias de Prática Clínica como Assunto , Amplitude de Movimento Articular , Estudos Retrospectivos , Suturas , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA