1.
Int Orthop ; 43(8): 1815-1821, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30141142

RESUMO

PURPOSE: Highly porous cups were developed to improve osseointegration and reduce the rate of aseptic loosening. Highly porous titanium cups could mix the reliability of titanium metal with an enhanced porosity, improving the bony ingrowth. The aim of this report was to assess the survival rates and reasons for revision of a highly porous titanium cup, Fixa Ti-Por (Adler Ortho, Milan, Italy), fabricated using an additive manufacturing. METHODS: The Registry of Prosthetic Orthopedic Implants (RIPO), the Emilia-Romagna region arthroplasty registry, was enquired about cementless cups, implanted since July 2007. Ti-Por cups were compared to all the other cementless sockets, acting as a control group. The survival rates and reasons for revision were evaluated and compared. Comparisons with the same articular couplings were also provided. RESULTS: When all the articular couplings were included, Ti-Por performed better, achieving a statistically higher survival rate than the control group (98.7% vs 97.9%) and a statistically lower incidence of cup aseptic loosening. In case of ceramic on polyethylene couplings, Ti-Por achieved similar survival rate: cup aseptic loosening in Ti-Por group was 0.2%, whereas the control group rated 0.4%. In ceramic-on-ceramic implants, the survival rate was similar in the two groups, Ti-Por achieving a cup aseptic loosening rate of 0.1% (vs 0.14% in the control group). CONCLUSION: Highly porous titanium cups showed trustworthy results at eight years, reducing the rate of aseptic loosening. Longer follow-ups, ion analyses, and pre-clinical in vivo studies would be helpful to better define the reliability of these devices and their advantages.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Materiais Biocompatíveis , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Falha de Prótese , Sistema de Registros , Titânio , Adulto Jovem
2.
Med Princ Pract ; 28(6): 559-565, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31079112

RESUMO

OBJECTIVE: Highly porous titanium cups have been recently introduced, with contradictory outcomes. A retrospective consecutive case series involving bilateral metachronous total hip arthroplasties (THA) performed with 2 different cups, i.e., Fixa (F) and Fixa Ti-Por (T) (Adler Ortho, Milan, Italy), and the same stem, was evaluated. T sockets, manufactured using electron beam melting, were supposed to prove superior in terms of clinical results, survival rates, and radiographic parameters in comparison to hydroxyapatite-coated F cups with conventional porosity. SUBJECTS AND METHODS: Twenty-four bilateral metachronous THAs with an F cup on one side and a T socket on the other side were evaluated. Preoperative and postoperative Harris hip scores (HHS) were collected for every patient. Radiographic signs of loosening were assessed. The radiographic signs of osseointegration (radiolucent lines, superolateral buttress, inferomedial buttress, radial trabeculae, and stress shielding) were evaluated. RESULTS: No intraoperative complications occurred. The mean HHS score was excellent and comparable in both groups. At the mean follow-up of 134 months (F) and 79 months (T), no cup or liner revisions were performed. No radiographic signs of loosening were reported. All of the patients revealed 3 parameters of good bony ingrowth at least. Both groups showed similar radiographic parameters regarding osseointegration, which were stable over the time. Stress shielding was more evident in the T cohort (p =0.07). CONCLUSION: Highly porous titanium cups produced using an additive manufacturing and electron beam melting technology achieved reliable midterm clinical and radiographic results not inferior to those of second-generation cups.


Assuntos
Artroplastia de Quadril/instrumentação , Durapatita/química , Prótese de Quadril , Titânio/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Materiais Revestidos Biocompatíveis/química , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Desenho de Prótese , Estudos Retrospectivos
3.
Hip Int ; 31(2): 250-257, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31480877

RESUMO

INTRODUCTION: Articular surface replacement (ASR) XL implants exhibit higher-than-expected revision rates, blood ion concentrations and soft tissue lesions, making revisions troublesome and potentially unsatisfying. Appropriate techniques and outcomes in ASR XL revisions are rarely documented. The aims of this study were the assessments of pre-revision data, post-revision clinical and radiographic outcomes and ion levels in isolated acetabular ASR XL revisions performed using highly porous titanium cups and Delta ceramic articulations. METHODS: 18 isolated acetabular ASR XL revisions in 16 patients were performed using Ti-Por cups (Adler Ortho, Milan, Italy) and Delta bearings (CeramTec, Plochingen, Germany). Pre-revision demographic, clinical, radiological and implant-related features were assessed. Clinical and radiographic parameters (cup positioning, osseointegration) after revisions were evaluated at a minimum follow-up of 5 years. Ion concentrations in blood and urine were collected in pre-revision setting and 1 year after revision. RESULTS: 4 complications occurred in 3 different revisions (16.7%), 1 dislocation, 2 infections, 1 psoas impingement. No re-revision was performed at 5 years (1 scheduled arthroscopy). Good clinical outcomes were achieved (HHS score: 88.3 ± 9.2). All the cups showed reassuring signs of osseointegration (>3 parameters). Blood ion concentrations significantly decreased: patients with Co blood ion concentration over the threshold (7 µg/l) decreased from 76.5% to 0%. No pre-revision or intraoperative data influenced the revision outcomes. CONCLUSIONS: Highly porous titanium cups and Delta ceramic articulations provided reliable mid-term clinical and radiographic outcomes in isolated acetabular ASR XL revisions. Ion concentrations significantly decreased. Multicentre prospective controlled studies are required to confirm these preliminary outcomes.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Seguimentos , Alemanha , Humanos , Itália , Porosidade , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação , Titânio