Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 347
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Heart Fail Rev ; 29(2): 417-430, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37940727

RESUMO

Device therapy is a nonpharmacological approach that presents a crucial advancement for managing patients with atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF). This review investigated the impact of device-based interventions and emphasized their potential for optimizing treatment for this complex patient demographic. Cardiac resynchronization therapy, augmented by atrioventricular node ablation with His-bundle pacing or left bundle-branch pacing, is effective for enhancing cardiac function and establishing atrioventricular synchrony. Cardiac contractility modulation and vagus nerve stimulation represent novel strategies for increasing myocardial contractility and adjusting the autonomic balance. Left ventricular expanders have demonstrated short-term benefits in HFpEF patients but require more investigation for long-term effectiveness and safety, especially in patients with AF. Research gaps regarding complications arising from left ventricular expander implantation need to be addressed. Device-based therapies for heart valve diseases, such as transcatheter aortic valve replacement and transcatheter edge-to-edge repair, show promise for patients with AF and HFpEF, particularly those with mitral or tricuspid regurgitation. Clinical evaluations show that these device therapies lessen AF occurrence, improve exercise tolerance, and boost left ventricular diastolic function. However, additional studies are required to perfect patient selection criteria and ascertain the long-term effectiveness and safety of these interventions. Our review underscores the significant potential of device therapy for improving the outcomes and quality of life for patients with AF and HFpEF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Qualidade de Vida , Resultado do Tratamento , Função Ventricular Esquerda
2.
Catheter Cardiovasc Interv ; 103(1): 129-136, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37786977

RESUMO

BACKGROUND: While studies have shown the advantages of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) in left atrial appendage closure (LAAC) preprocedural planning for WATCHMAN™ legacy and FLX devices, there has been no reported long-term data for this approach. OBJECTIVES: We sought to evaluate long-term outcomes using CTA-based preprocedural planning for LAAC using the WATCHMAN™ device. METHODS: A prospective analysis of 231 consecutive patients who underwent LAAC in a single, large academic hospital in the United States was conducted over a 5-year period. CTA-guided preprocedural planning was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. Rates of death, cerebral embolism, systemic embolism, and major and minor bleeding were recorded. Adjusted predicted stroke and major bleeding rates were derived from CHA2DS2-Vasc and HAS-BLED scores, respectively. RESULTS: From January 26, 2017, to November 23, 2021, 231 patients underwent LAAC with CTA preprocedural planning by two operating physicians. The mean age of patients was 76.5 ± 8.4. 59.7% of patients were male. Mean CHA2DS2VASc and HAS-BLED scores were 4.5 ± 1.4 and 3.9 ± 0.9, respectively. All procedures were performed with intracardiac echo (100%). The procedural success rate was 99.1%. The CTA sizing strategy accurately predicted the implant size in 93.5% of patients. Mean number of devices used was 1.10 ± 0.3. Peri-procedural complication rate was 2.2%. 6 patients were lost to follow-up. Mean follow-up was 608.94 days with a total of 377.04 patient years. Median follow-up period of 368 days (interquartile range: 209-1067 days). There were 51 deaths from all causes (13.52 per 100 patient-years), 10 cases of cerebral embolism (2.65 per 100 patient-years), 2 cases of systemic embolism (0.53 per 100 patient-years), 17 cases of major bleeding (4.50 per 100 patient-years), and 31 cases of minor bleeding (8.2 per 100 patient-years). All-cause mortality at 1, 2, and 3 years was 12.7%, 20.9%, and 29.2%, respectively. CV event rates at 1, 2, and 3 years were 2.1%, 6.6%, and 10.5%, respectively. CONCLUSIONS: CTA-based preprocedural planning is accurate in predicting device size for LAAC and associated with excellent clinical outcomes at 5 years.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Embolia , Embolia Intracraniana , Acidente Vascular Cerebral , Humanos , Masculino , Feminino , Seguimentos , Oclusão do Apêndice Atrial Esquerdo , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Angiografia por Tomografia Computadorizada , Resultado do Tratamento , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Embolia Intracraniana/prevenção & controle , Apêndice Atrial/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Hemorragia , Ecocardiografia Transesofagiana/efeitos adversos
3.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38597211

RESUMO

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Fenótipo , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
4.
Am J Kidney Dis ; 81(3): 307-317.e1, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36208798

RESUMO

RATIONALE & OBJECTIVE: Direct oral anticoagulants (DOACs) have progressively replaced vitamin K antagonists (VKAs) for stroke prevention in patients with nonvalvular atrial fibrillation (AF). DOACs cause fewer bleeding complications, but their other advantages, particularly related to kidney outcomes, remain inconclusive. We studied the risks of chronic kidney disease (CKD) progression and acute kidney injury (AKI) after DOAC and VKA administration for nonvalvular AF. STUDY DESIGN: Retrospective cohort study. SETTING & PARTICIPANTS: Cohort study of Swedish patients enrolled in the Stockholm Creatinine Measurements (SCREAM) project with a diagnosis of nonvalvular AF during 2011-2018. EXPOSURE: Initiation of DOAC or VKA treatment. OUTCOME: Primary outcomes were CKD progression (composite of >30% estimated glomerular filtration rate [eGFR] decline and kidney failure) and AKI (by diagnosis or KDIGO-defined transient creatinine elevations). Secondary outcomes were death, major bleeding, and the composite of stroke and systemic embolism. ANALYTICAL APPROACH: Propensity score weighted Cox regression was used to balance 50 baseline confounders. Sensitivity analyses included falsification end points, subgroups, and estimation of per-protocol effects. RESULTS: We included 32,699 patients (56% initiated DOAC) who were observed for a median of 3.8 years. Their median age was 75 years, 45% were women, and 27% had an eGFR <60mL/min/1.73m2. The adjusted HRs for DOAC versus VKA were 0.87 (95% CI, 0.78-0.98) for the risk of CKD progression and 0.88 (95% CI, 0.80-0.97) for AKI. HRs were 0.77 (95% CI, 0.67-0.89) for major bleeding, 0.93 (95% CI, 0.78-1.11) for the composite of stroke and systemic embolism, and 1.04 (95% CI, 0.95-1.14) for death. The results were similar across subgroups of age, sex, and baseline eGFR when restricting to patients at high risk for thromboembolic events and when censoring follow up at treatment discontinuation or change in type of anticoagulation. LIMITATIONS: Missing information on time in therapeutic range and treatment dosages. CONCLUSIONS: Among patients with nonvalvular AF treated in routine clinical practice compared with VKA use, DOAC use was associated with a lower risk of CKD progression, AKI, and major bleeding but a similar risk of the composite of stroke, systemic embolism, or death.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Embolia , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Masculino , Fibrilação Atrial/complicações , Estudos de Coortes , Estudos Retrospectivos , Creatinina , Anticoagulantes , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/induzido quimicamente , Embolia/complicações , Embolia/tratamento farmacológico , Embolia/prevenção & controle , Insuficiência Renal Crônica/complicações , Injúria Renal Aguda/induzido quimicamente , Administração Oral
5.
Eur J Clin Pharmacol ; 79(12): 1631-1639, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37755492

RESUMO

BACKGROUND: Direct oral anticoagulants (DOACs) are increasingly recommended over warfarin in stroke prevention for patients with non-valvular atrial fibrillation (AF). However, there is an important evidence gap in choosing the most appropriate DOAC for Chinese patients in clinical practice. METHODS: A multi-criteria decision analysis (MCDA) was adopted to build a scoring framework. Attributes and criteria were identified and determined by a scoping literature review, two rounds of Delphi surveys, and a consensus meeting. Weights of each attribute and criterion in the framework were determined using analytic hierarchy process (AHP). Evidence was collected based on the domestic or at least Asian data. Scoring methods for each criterion were developed depended on their characteristics and determined with an expert consensus meeting. Comprehensive scores of each DOAC were calculated based on the utility scores of each criterion and their corresponding weights. RESULTS: A total of 5 attributes, including safety, efficacy, costs/cost-effectiveness, suitability, and accessibility, were determined, and 16 criteria were under the 5 attributes. The safety and efficacy were ranked as the top two important attributes with the weights of 38.8% and 35.9%, respectively, while the suitability received the lowest weight of 7.9%. The comprehensive score for edoxaban was the highest (72.3), followed by dabigatran (49.7), rivaroxaban (37.9), and apixaban (35.8). CONCLUSIONS: This study provided a scoring framework developed for comprehensive evaluation of DOACs in China. The ranking of DOACs could help to support the decision-making in clinical practice. The framework could provide a reference for comprehensive evaluation of other drugs.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/tratamento farmacológico , Varfarina/uso terapêutico , Rivaroxabana/uso terapêutico , Dabigatrana/uso terapêutico , Piridonas/uso terapêutico , Administração Oral
6.
J Thromb Thrombolysis ; 56(4): 518-528, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37452906

RESUMO

BACKGROUND: The effectiveness and safety of direct oral anticoagulants (DOACs) in patients with atrial fibrillation (AF) and advanced kidney disease (AKD) has not been fully established. OBJECTIVES: To determine the effectiveness and safety related to pooled or specific DOACs to that with warfarin in patients with AF and AKD. METHODS: Patients with AF and AKD (estimated glomerular filtration rate < 30 mL/min) who received DOAC or warfarin from July 2011 to December 2020 were retrospectively identified in a medical center in Taiwan. Primary outcomes were hospitalized for stroke/systemic embolism and major bleeding. Secondary outcomes included any ischemia and any bleeding. RESULTS: A total of 1,011 patients were recruited, of whom 809 (80.0%) were in the DOACs group (15.3% dabigatran, 25.4% rivaroxaban, 25.2% apixaban, and 14.1% edoxaban), and 202 (20.0%) in the warfarin group. DOACs had considerably lower risks of stroke/systemic embolism (adjusted hazard ratio [aHR] 0.29; 95% CI, 0.09-0.97) and any ischemia (aHR, 0.42; 95% CI, 0.22-0.79), but had comparable risks of major bleeding (aHR, 0.99; 95% CI, 0.34-2.92) and any bleeding (aHR, 0.74; 95% CI, 0.50-1.09) than warfarin. Apixaban was linked to considerably lower risks of any ischemia (aHR, 0.13; 95% CI, 0.04-0.48) and any bleeding (aHR, 0.53; 95% CI, 0.28-0.99) than warfarin. CONCLUSION: Among patients with AF and AKD, DOACs were linked to a lower risk of ischemic events, and apixaban was linked to a lower risk of any ischemia and any bleeding than warfarin.

7.
Am J Kidney Dis ; 80(5): 569-579.e1, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35469965

RESUMO

BACKGROUND & OBJECTIVES: Comparison of clinical outcomes across anticoagulation regimens using different apixaban dosing or warfarin is not well-defined in patients with nonvalvular atrial fibrillation (AF) who are receiving dialysis. This study compared these outcomes in a US national cohort of patients with kidney failure receiving maintenance dialysis. STUDY DESIGN: Retrospective cohort study. SETTING & PARTICIPANTS: Patients receiving dialysis represented in the US Renal Data System database 2013-2018 who had AF and were treated with apixaban or warfarin. EXPOSURE: First prescribed treatment with apixaban dosed according to the label, apixaban dosed below the label, or warfarin. OUTCOME: Ischemic stroke/systemic embolism, major bleeding, and all-cause mortality. ANALYTICAL APPROACH: Cox proportional hazards models with inverse probability of treatment weighting. Analyses simulating an intention-to-treat (ITT) approach as well as those incorporating censoring at drug switch or discontinuation (CAS) were also implemented. Inverse probability of censoring weighting was used to account for possible informative censoring. RESULTS: Among 17,156 individuals, there was no difference in risk of stroke/systemic embolism among the label-concordant apixaban, below-label apixaban, and warfarin treatment groups. Both label-concordant (HR, 0.67 [95% CI, 0.55-0.81]) and below-label (HR, 0.68 [95% CI, 0.55-0.84]) apixaban dosing were associated with a lower risk of major bleeding compared with warfarin in ITT analyses. Compared with label-concordant apixaban, below-label apixaban was not associated with a lower bleeding risk (HR, 1.02 [95% CI, 0.78-1.34]). In the ITT analysis of mortality, label-concordant apixaban dosing was associated with a lower risk versus warfarin (HR, 0.85 [95% CI, 0.78-0.92]) while there was no significant difference in mortality between below-label dosing of apixaban and warfarin (HR, 0.97 [95% CI, 0.89-1.05]). Overall, results were similar for the CAS analyses. LIMITATIONS: Study limited to US Medicare beneficiaries; reliance on administrative claims to ascertain outcomes of AF, stroke, and bleeding; likely residual confounding. CONCLUSIONS: Among patients with nonvalvular AF undergoing dialysis, warfarin is associated with an increased risk of bleeding compared with apixaban. The risk of bleeding with below-label apixaban was not detectably less than with label-concordant dosing. Label-concordant apixaban dosing is associated with a mortality benefit compared to warfarin. Label-concordant dosing, rather than reduced-label dosing, may offer the most favorable benefit-risk trade-off for dialysis patients with nonvalvular AF.


Assuntos
Fibrilação Atrial , Embolia , Acidente Vascular Cerebral , Humanos , Idoso , Estados Unidos/epidemiologia , Varfarina/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Anticoagulantes/uso terapêutico , Estudos Retrospectivos , Diálise Renal/efeitos adversos , Administração Oral , Medicare , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Embolia/complicações , Embolia/tratamento farmacológico , Medição de Risco , Estudos de Coortes
8.
J Cardiovasc Electrophysiol ; 33(8): 1781-1787, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35586899

RESUMO

BACKGROUND: While there is recent data suggesting an advantage of computed tomography angiography (CTA) over transesophageal echocardiography (TEE) for preprocedural left atrial appendage closure (LAAC) planning, there is limited published experience for sizing strategies. Device sizing for LAAC may be challenging and noninvasive algorithms that improve this selection process are warranted. OBJECTIVES: We sought to evaluate the safety and the feasibility for the implementation of a novel CTA-based sizing methodology for WATCHMAN™ FLX device in a series of patients undergoing LAAC using the TruPlan™ software package. METHODS: A prospective analysis of 136 consecutive patients who underwent LAAC over a 12-month period in a single, large academic hospital in the United States was conducted. CTA-guided preprocedural planning and intracardiac echocardiography (ICE) was performed in all. Procedural success, adverse events, length of procedure, number of devices used, and length of stay were evaluated. RESULTS: A total of 136 patients who underwent LAAC procedure with WATCHMAN™ FLX platform between October 1, 2020 until September 30, 2021 were included. The pre-specified protocol using CTA and ICE was implemented in all patients (100%). Mean CHA2 DS2 VASc score was 4.4 ± 1.3 and the mean HAS-BLED score was 3.9 ± 0.8. ICE-guided 100% transseptal puncture success rate was 100% with 98.5% of overall procedural success rate. Preprocedural CTA sizing strategy accurately predicted the implanted size in 91.1% of patients. Ten patients (7.4%) required another sized device and 2 cases were aborted. At 45-day follow-up, only 1 patient (0.7%) had significant peri-device leak (≥5 mm) on TEE. CONCLUSIONS: CTA-based preprocedural sizing methodology for WATCHMAN™ FLX in LAAC was safe, feasible and associated with excellent procedural outcomes. Further studies are warranted to confirm if the features specific to TruPlan™ may reduce the number of deployment attempts, the number of devices utilized in the procedure, and the risk of complications.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia Transesofagiana/métodos , Humanos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 100(7): 1307-1313, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36316818

RESUMO

BACKGROUND: Same-day discharge (SDD) following left atrial appendage closure (LAAC) is increasingly common but predictors of successful SDD and 1-year clinical outcomes have not been described. OBJECTIVE: The purpose of this study was to explore predictors of successful SDD and report 1-year outcomes in patients undergoing LAAC with SDD. METHODS: A prospective analysis was performed over a 20-month period of 225 consecutive patients that underwent LAAC in a large, academic hospital. All patients included in the study underwent a SDD protocol. Baseline characteristics and 1-year outcomes of patients discharged same day of the procedure versus those that required at least one overnight stay were compared. Adverse events, procedural success, and procedure times were evaluated. RESULTS: One hundred and sixty-one patients (72%) of patients were discharged the same day and 64 patients (28%) required at least an overnight stay (non-SDD: NSDD). NSDD patients were older and more often female. Procedure time was also longer in the NSDD group than in the SDD (63.4 vs. 55.1 min; p = 0.01). While overall procedural success rates were similar between the SDD and NSDD groups (99.4% vs. 98.4%; p = 0.39), NSDD patients had more complications (9.4% vs. 0%; p = 0.01) and higher number of devices per procedure (1.2 vs. 1.0; p = 0.01) as compared to SDD. At 1 year, there were no significant difference between the SDD and NSDD groups in stroke (1.1% vs. 0%; log-rank p = 0.44) and all-cause mortality (3.9% vs. 4.7%; log-rank p = 0.70). CONCLUSION: In this single-center LAAC experience, female sex, older age, and longer procedure duration were associated with higher likelihood for need of overnight stay. At 1-year follow-up, there were no significant differences in stroke events and death rates between SDD and NSDD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Feminino , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/complicações , Alta do Paciente , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento , Masculino
10.
Eur J Clin Pharmacol ; 78(10): 1589-1600, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35941300

RESUMO

PURPOSE: Transcatheter aortic valve replacement (TAVR) is increasingly carried out in patients with aortic valvular conditions. Atrial fibrillation (AF) is a common comorbidity among patients undergoing TAVR. Despite this, there remains a paucity of data and established guidelines regarding anticoagulation use post-TAVR in patients with AF. METHODS: Four databases were searched from inception until 12 October 2021. A title and abstract sieve, full-text review and data extraction were conducted by independent authors, and articles including patients without AF were excluded. The Review Manager (Version 5.4) was utilised in data analysis. RESULTS: A total of 25,199 post-TAVR patients with AF were included from seven articles, with 9764 patients on non-vitamin K antagonist oral anticoagulants (NOAC) and 15,435 patients on vitamin K antagonists (VKA). In this analysis, there was a significantly lower risk of all-cause mortality at 1 year (RR: 0.75, CI: 0.58-0.97, p = 0.04, I2 = 56%), and bleeding at 1 year (RR: 0.73, CI: 0.68-0.79, p = < 0.00001, I2 = 0%), between patients on NOAC and VKA. There were no detectable differences between patients on NOAC and VKA for all-cause mortality at 2 years, stroke within 30 days, stroke within 1 year, ischaemic stroke at 1 year and life-threatening bleeding at 30 days. CONCLUSION: While the results of this analysis reveal NOAC as a potential alternate treatment modality to VKA in post-TAVR patients with AF, further research is needed to determine the full safety and efficacy profile of NOAC (PROSPERO: CRD42021283548).


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Administração Oral , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Isquemia Encefálica/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Hemorragia/induzido quimicamente , Humanos , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Am J Kidney Dis ; 78(2): 180-189, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33421454

RESUMO

RATIONALE & OBJECTIVE: Comparing kidney disease progression among patients treated with direct oral anticoagulants (DOACs) versus warfarin has not been well studied. We hypothesized that apixaban would be associated with lower risks of progression of chronic kidney disease (CKD) and progression to incident kidney failure than warfarin in patients with atrial fibrillation (AF). STUDY DESIGN: Retrospective cohort study. SETTING & PARTICIPANTS: Medicare recipients with stage 3, 4, or 5 CKD and incident AF who received a new prescription for apixaban or warfarin from 2013 through 2017. EXPOSURE: Apixaban or warfarin. OUTCOMES: Progression to incident kidney failure or, separately, to a more advanced stage of CKD. ANALYTICAL APPROACH: Marginal structural cause-specific proportional hazards models with inverse probability weighting to estimate marginal hazard ratios (HRs) for each outcome. HRs compared apixaban to warfarin in intention-to-treat and censored-at-drug-switch analyses. RESULTS: 12,816 individuals met inclusion criteria (50.3% received apixaban; 49.7% received warfarin). After weighting, the mean age of the cohort was 80 ± 7 years, 51% were women, and 88% were White. Approximately 84% had stage 3, 15% had stage 4, and 1% had stage 5 CKD. In the intention-to-treat analysis, apixaban, relative to warfarin, was associated with an HR of developing incident kidney failure of 0.98 (95% confidence interval [CI], 0.79-1.22) and of CKD stage progression of 0.90 (95% CI, 0.82-0.99). Corresponding HRs for censored-at-drug-switch analyses were 0.81 (95% CI, 0.56-1.17) and 0.81 (95% CI, 0.70-0.92). Results were similar for a series of subgroup and sensitivity analyses. LIMITATIONS: CKD was defined based on diagnosis codes from claims; findings may not be generalizable to non-Medicare CKD populations. CONCLUSIONS: Apixaban, compared with warfarin, was associated with lower risk of CKD stage progression, but not with incident kidney failure.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/uso terapêutico , AVC Isquêmico/prevenção & controle , Falência Renal Crônica/epidemiologia , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Insuficiência Renal Crônica/metabolismo , Varfarina/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Progressão da Doença , Feminino , Humanos , AVC Isquêmico/etiologia , Masculino , Medicare , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos
12.
Am J Kidney Dis ; 78(5): 678-689.e1, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-33872690

RESUMO

OBJECTIVE: To evaluate the relative efficacy and safety of different oral anticoagulant agents (OACs) for patients with atrial fibrillation (AF) and chronic kidney disease (CKD). STUDY DESIGN: Systematic review and pairwise and Bayesian network meta-analysis. SETTING & STUDY POPULATIONS: Adult patients with AF and CKD stages 3-5D who received OACs. SELECTION CRITERIA FOR STUDIES: Randomized controlled trials (RCTs) and observational studies that reported the efficacy and safety outcomes of subgroups with a glomerular filtration rate (GFR)<60mL/min. DATA EXTRACTION: Two reviewers independently abstracted data, assessed study quality, and rated the strength of evidence (SOE). ANALYTICAL APPROACH: Random-effects models using restricted maximum-likelihood methods were fit for the pairwise meta-analyses as well as a network meta-analysis within a Bayesian framework. RESULTS: Pairwise meta-analysis including 8 RCTs and 46 observational studies showed that direct OACs (DOACs) were superior to warfarin in preventing thromboembolic events (hazard ratio [HR], 0.86 [95% CI, 0.78-0.95]), without heterogeneity (I2=10.5%), and in reducing the risk of bleeding events (HR, 0.81 [95% CI, 0.66-0.99]), with substantial heterogeneity (I2=69.8%), in patients with AF and a GFR of 15-60mL/min. Bayesian network meta-analysis including 8 RCTs showed that dose-adjusted apixaban and a 15-mg dose of edoxaban were superior to the other OAC regimens in reducing bleeding events. Dose-adjusted apixaban was more effective than edoxaban in preventing thromboembolic events for patients with AF and GFR in the range of 25-50 or 30-50mL/min. In dialysis recipients with AF, the use of OACs increased the risk of bleeding events by 28% (HR, 1.28 [95% CI, 1.03-1.60]) without significant beneficial effects versus not using anticoagulants. LIMITATIONS: Low SOE and heterogeneity in most comparisons. CONCLUSIONS: This study suggests that DOACs are superior to warfarin for the prevention of thromboembolic events and reduction in bleeding risk in patients with AF and mild to moderate kidney disease. However, the low SOE limits the conclusions that can be drawn about the preferred DOAC. Notably, the use of OACs may increase bleeding risk without significant benefits in dialysis recipients with AF. REGISTRATION: Registered at PROSPERO with identification number CRD42018090896.


Assuntos
Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Humanos , Metanálise em Rede , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/tratamento farmacológico , Insuficiência Renal Crônica/epidemiologia
13.
Am J Kidney Dis ; 77(6): 907-919, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33309861

RESUMO

RATIONALE & OBJECTIVE: Circulating cardiac biomarkers may signal potential mechanistic pathways involved in heart failure (HF) and atrial fibrillation (AF). Single measures of circulating cardiac biomarkers are strongly associated with incident HF and AF in chronic kidney disease (CKD). We tested the associations of longitudinal changes in the N-terminal fragment of the prohormone brain natriuretic peptide (NT-proBNP), high-sensitivity troponin T (hsTnT), galectin-3, growth differentiation factor 15 (GDF-15), and soluble ST-2 (sST-2) with incident HF and AF in patients with CKD. STUDY DESIGN: Observational, case-cohort study design. SETTING & PARTICIPANTS: Adults with CKD enrolled in the Chronic Renal Insufficiency Cohort study. EXPOSURES: Biomarkers were measured at baseline and 2 years later among those without kidney failure. We created 3 categories of absolute change in each biomarker: the lowest quartile, the middle 2 quartiles, and the top quartile. OUTCOMES: The primary outcomes were incident HF and AF. ANALYTICAL APPROACH: Cox proportional hazards regression models were used to test the associations of the change categories of each cardiac biomarker with each outcome (with the middle 2 quartiles of change as the referent group), adjusting for potential confounders and baseline concentrations of each biomarker. RESULTS: The incident HF analysis included 789 participants (which included 138 incident HF cases), and the incident AF analysis included 774 participants (123 incident AF cases). In multivariable models, the top quartile of NT-proBNP change (>232pg/mL over 2years) was associated with increased risk of incident HF (HR, 1.79 [95% CI, 1.06-3.04]) and AF (HR, 2.32 [95% CI, 1.37-3.93]) compared with the referent group. Participants in the top quartile of sST2 change (>3.37ng/mL over 2years) had significantly greater risk of incident HF (HR, 1.89 [95% CI, 1.13-3.16]), whereas those in the bottom quartile (≤-3.78ng/mL over 2years) had greater risk of incident AF (HR, 2.43 [95% CI, 1.39-4.22]) compared with the 2 middle quartiles. There was no association of changes in hsTnT, galectin-3, or GDF-15 with incident HF or AF. LIMITATIONS: Observational study. CONCLUSIONS: In CKD, increases in NT-proBNP were significantly associated with greater risk of incident HF and AF, and increases in sST2 were associated with HF. Further studies should investigate whether these markers of subclinical cardiovascular disease can be modified to reduce the risk of cardiovascular disease in CKD.


Assuntos
Fibrilação Atrial/sangue , Insuficiência Cardíaca/sangue , Insuficiência Renal Crônica/sangue , Idoso , Fibrilação Atrial/etiologia , Biomarcadores/sangue , Estudos de Coortes , Feminino , Insuficiência Cardíaca/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Insuficiência Renal Crônica/complicações
14.
Clin Proteomics ; 18(1): 1, 2021 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-33407078

RESUMO

BACKGROUND: Atrial fibrillation (AF) is the most common cardiac heterogeneous rhythm disorder. It represents a major cause of mortality and morbidity, mainly related to embolic events and heart failure. Mechanisms of AF are complex and remain incompletely understood. Recent evidence suggests exosomes are membrane-coated objects released by many cell-types. Their presence in body fluids and the variable surface composition and content render them attractive as a mechanism for potential biomarkers. However, the content of serum exosomes of AF patients has not been fully delineated. METHODS: In this work, the serum exosomes from AF patients and healthy donors were used to compare changes in the exosome protein content. Exosomes were isolated from serum of AF patients and healthy donors and their purity was confirmed by Western blotting assays and transmission electron microscopy (TEM). Label-free LC-MS/MS quantitative proteomic analysis was applied to analyze protein content of serum exosomes. RESULTS: A total of 440 exosomal protein groups were identified, differentially expressed proteins were filtrated with fold change ≥ 2.0 (AF/controls protein abundance ratio ≥ 2 or ≤ 0.5) and p value less than 0.05 (p < 0.05), significantly changed in abundance group contains 39 elevated proteins and 18 reduced proteins, while consistent presence/absence expression profile group contains 40 elevated proteins and 75 reduced proteins. Bioinformatic analysis of differential exosomal proteins confirmed the significant enrichment of components involved in the anticoagulation, complement system and protein folding. Parallel-Reaction Monitoring Relative Quantitative Analysis (PRM) further suggested that AF related to complement system and protein folding. CONCLUSIONS: These results revealed the composition and potential function of AF serum exosomes, thus providing a new perspective on the complement system and protein folding to AF.

15.
Rev Cardiovasc Med ; 22(3): 1019-1027, 2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34565103

RESUMO

The populations included in the randomized controlled clinical trials and observational studies were different. The effectiveness and safety of rivaroxaban for stroke prevention in patients with atrial fibrillation (AF) varied among studies. This study aimed to estimate the real-world outcomes of rivaroxaban in patients with AF accurately. A discrete event simulation (DES) was used to predict the counterfactual results of the ROCKET AF study. The hypothetical cohorts of patients were generated using Monte Carlo simulation according to the baseline covariate distributions that matched the marginal distribution of covariates reported in the ROCKET AF and three observational studies. The DES model structure was constructed based on a priori knowledge about disease progression and possible outcomes of patients with AF. The DES model accurately replicated the overall results of the ROCKET AF study. Both predicted stroke/systematic embolism (SE) and major bleeding rates were lower in the three observational studies than in the simulated ROCKET AF study. The risk difference of stroke/SE and major bleeding was not significant among the predicted outcomes of the three observational studies. Although some differences existed in the absolute rates of stroke/SE and major bleeding between observed and simulated studies, the results confirmed that rivaroxaban was noninferior to warfarin for the prevention of stroke/systematic embolism with no significance in the risk of major bleeding in large AF populations, which was similar to the results of ROCKET AF.


Assuntos
Fibrilação Atrial , Simulação por Computador , Embolia , Acidente Vascular Cerebral , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/efeitos adversos , Humanos , Método de Monte Carlo , Estudos Observacionais como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Rivaroxabana/efeitos adversos , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento , Varfarina
16.
Neurol Sci ; 42(10): 4139-4148, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33528671

RESUMO

BACKGROUND: In recent years, the implantable cardiac monitors (ICM) have enhanced the recognition ability of atrial fibrillation (AF), which makes ICM have a new application in AF detection. We conducted a meta-analysis to determine the total incidence of newly found AF detected by ICM after cryptogenic stroke and to evaluate the factors related to the detection of AF. METHODS: A literature search was conducted in the PubMed, EMBASE, Web of Science, and Cochrane library databases until March 1, 2020. Studies that reported the detection rate of AF using ICM in cryptogenic stroke patients with negative initial AF screening were analyzed. RESULTS: A total of 23 studies were included. The overall proportion of AF detected by ICM in cryptogenic stroke patients was 25% (95% confidence interval [CI], 22-29%). The rate of AF detected by ICM was independently related to both cardiac monitoring time (coefficient = 0.0003; 95% CI, 0.0001-0.0005; P = 0.0001) and CHA2DS2-VASc score (coefficient = 0.0834; 95% CI, 0.0339-0.1329; P = 0.001). In subgroup analysis, we found a significant difference in the detection rate of AF for monitoring duration (< 6 months: 9.6% [95% CI, 4.4-16.4%]; ≥ 6 and ≤ 12 months: 19.3% [95% CI, 15.9-23.0%]; > 12 and ≤ 24 months: 23.6% [95% CI, 19.9-27.5%]; > 24 months and ≤ 36 months: 36.5% [95% CI, 24.2-49.9%]; P < 0.001), and continent (Europe: 26.5% [95% CI, 22.2-31.0%]; North America: 16.0% [95% CI, 10.3-22.6%]; Asia: 17.4% [95% CI, 12.4-23.0%]; P = 0.005). CONCLUSIONS: The longer the time of ICM monitoring after cryptogenic stroke, the higher the detection rate of AF. Further research is still needed to determine the optimal duration of long-term cardiac monitoring.


Assuntos
Fibrilação Atrial , AVC Isquêmico , Acidente Vascular Cerebral , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Eletrocardiografia Ambulatorial , Humanos , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo
17.
Sensors (Basel) ; 21(13)2021 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34202805

RESUMO

Automatic detection of abnormal heart rhythms, including atrial fibrillation (AF), using signals obtained from a single-lead wearable electrocardiogram (ECG) device, is useful for daily cardiac health monitoring. In this study, we propose a novel image-based deep learning framework to classify single-lead ECG recordings of short variable length into several different rhythms associated with arrhythmias. By transforming variable-length 1D ECG signals into fixed-size 2D time-morphology representations and feeding them to the beat-interval-texture convolutional neural network (BIT-CNN) model, we aimed to learn the comprehensible characteristics of beat shape and inter-beat patterns over time for arrhythmia classification. The proposed approach allows feature embedding vectors to provide interpretable time-morphology patterns focused at each step of the learning process. In addition, this method reduces the number of model parameters needed to be trained and aids visual interpretation, while maintaining similar performance to other CNN-based approaches to arrhythmia classification. For experiments, we used the PhysioNet/CinC Challenge 2017 dataset and achieved an overall F1_NAO of 81.75% and F1_NAOP of 76.87%, which are comparable to those of the state-of-the-art methods for variable-length ECGs.


Assuntos
Fibrilação Atrial , Eletrocardiografia , Algoritmos , Humanos , Redes Neurais de Computação
18.
Entropy (Basel) ; 23(9)2021 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-34573824

RESUMO

Entropy algorithm is an important nonlinear method for cardiovascular disease detection due to its power in analyzing short-term time series. In previous a study, we proposed a new entropy-based atrial fibrillation (AF) detector, i.e., EntropyAF, which showed a high classification accuracy in identifying AF and non-AF rhythms. As a variation of entropy measures, EntropyAF has two parameters that need to be initialized before the calculation: (1) tolerance threshold r and (2) similarity weight n. In this study, a comprehensive analysis for the two parameters determination was presented, aiming to achieve a high detection accuracy for AF events. Data were from the MIT-BIH AF database. RR interval recordings were segmented using a 30-beat time window. The parameters r and n were initialized from a relatively small value, then gradually increased, and finally the best parameter combination was determined using grid searching. AUC (area under curve) values from the receiver operator characteristic curve (ROC) were compared under different parameter combinations of parameters r and n, and the results demonstrated that the selection of these two parameters plays an important role in AF/non-AF classification. Small values of parameters r and n can lead to a better detection accuracy than other selections. The best AUC value for AF detection was 98.15%, and the corresponding parameter combinations for EntropyAF were as follows: r = 0.01, n = 0.0625, 0.125, 0.25, or 0.5; r = 0.05 and n = 0.0625, 0.125, or 0.25; and r = 0.10 and n = 0.0625 or 0.125.

19.
J Cell Biochem ; 121(8-9): 3752-3763, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31680326

RESUMO

Long noncoding RNAs (lncRNAs) are an emerging class of RNA species that could participate in some critical pathways and disease pathogenesis. However, the underlying molecular mechanism of lncRNAs in atrial fibrillation (AF) is still not fully understood. In the present study, we analyzed RNA-seq data of paired left and right atrial appendages from five patients with AF and other five patients without AF. Based on the gene expression profiles of 20 samples, we found that a majority of genes were aberrantly expressed in both left and right atrial appendages of patients with AF. Similarly, the dysregulated pathways in the left and right atrial appendages of patients with AF also bore a close resemblance. Moreover, we predicted regulatory lncRNAs that regulated the expression of adjacent protein-coding genes (PCGs) or interacted with proteins. We identified that NPPA and its antisense RNA NPPA-AS1 may participate in the pathogenesis of AF by regulating the muscle contraction. We also identified that RP11 - 99E15.2 and RP3 - 523K23.2 could interact with proteins ITGB3 and HSF2, respectively. RP11 - 99E15.2 and RP3 - 523K23.2 may participate in the pathogenesis of AF via regulating the extracellular matrix binding and the transcription of HSF2 target genes, respectively. The close association of the lncRNA-interacting proteins with AF further demonstrated that these two lncRNAs were also associated with AF. In conclusion, we have identified key regulatory lncRNAs implicated in AF, which not only improves our understanding of the lncRNA-related molecular mechanism underlying AF but also provides computationally predicted regulatory lncRNAs for AF researchers.

20.
Am J Kidney Dis ; 75(2): 214-224, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31542235

RESUMO

RATIONALE & OBJECTIVE: Patients with kidney failure treated with maintenance dialysis experience a high rate of mortality, in part due to sudden cardiac death caused by arrhythmias. The prevalence of arrhythmias, including the subset that are clinically significant, is not well known. This study sought to estimate the prevalence of arrhythmias, characterize the pattern of arrhythmic events in relation to dialysis treatments, and identify associated clinical characteristics. STUDY DESIGN: Cross-sectional study. SETTING & PARTICIPANTS: 152 patients with kidney failure treated with maintenance dialysis in Denmark. EXPOSURES: Dialysis treatment; clinical characteristics; cardiac output and preload defined using echocardiography. OUTCOMES: Prevalence and pattern of arrhythmias on 48-hour Holter monitoring; odds ratios for arrhythmias. ANALYTICAL APPROACH: Descriptive analysis of the prevalence of arrhythmias. Pattern of arrhythmias described using a repeated-measures negative binomial regression model. Associations between clinical characteristics and echocardiographic findings with arrhythmias were assessed using logistic regression. RESULTS: Among the 152 patients studied, 83.6% were treated with in-center dialysis; 10.5%, with home hemodialysis; and 5.9%, with peritoneal dialysis. Premature atrial and ventricular complexes were seen in nearly all patients and 41% had paroxysmal supraventricular tachycardia. Clinically significant arrhythmias included persistent atrial fibrillation observed among 8.6% of patients, paroxysmal atrial fibrillation among 3.9%, nonsustained ventricular tachycardia among 19.7%, bradycardia among 4.6%, advanced second-degree atrioventricular block among 1.3%, and third-degree atrioventricular block among 2.6%. Premature ventricular complexes were more common on dialysis days, while tachyarrhythmias were more often observed during dialysis and in the immediate postdialytic period. Older age (OR per 10 years older, 1.53; 95% CI, 1.15-2.03; P=0.003), elevated preload (OR, 4.02; 95% CI, 1.05-15.35; P=0.04), and lower cardiac output (OR per 1L/min greater, 0.66; 95% CI, 0.44-1.00; P=0.05) were independently associated with clinically significant arrhythmias. LIMITATIONS: Arrhythmia monitoring limited to 48 hours; small sample size; heterogeneous nature of the population, risk for residual confounding. CONCLUSIONS: Arrhythmias, including clinically significant abnormal rhythms, were common. Tachyarrhythmias were more frequent during dialysis and the immediate postdialytic period. The relevance of these findings to clinical outcomes requires additional study.


Assuntos
Arritmias Cardíacas/etiologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Estudos Transversais , Dinamarca/epidemiologia , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Incidência , Falência Renal Crônica/complicações , Falência Renal Crônica/mortalidade , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA