RESUMO
AIM AND PATIENTS: The aim of the present study was to assess the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning induced by dipyridamole infusion. We selected 52 ischemic patients (43 males; mean age 65.5 ± 7.64), with CAD documented by angiography. Ischemia was defined as a summed difference score ≥ 5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of 99mTc-tetrofosmin after stress and at rest. RESULTS: The post-stress LVEF was significantly lower than rest LVEF (48.3% ± 14.5% vs. 50.7% ± 15%; P = 0.0001). The wall thickening summed difference score was 3.97 ± 3.84 (P = 0.0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS) (P = 0.001). We divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. CONCLUSIONS: WT-SDS showed a better correlation with the degree of ischemia than the depression in the global function of the left ventricle. It allowed to better identify the stunning phenomenon in patients submitted to pharmacological stress.
Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Isquemia Miocárdica/diagnóstico por imagem , Miocárdio Atordoado/diagnóstico por imagem , Idoso , Dipiridamol , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Isquemia Miocárdica/fisiopatologia , Miocárdio Atordoado/etiologia , Compostos Organofosforados , Compostos de Organotecnécio , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , VasodilatadoresRESUMO
AIM AND PATIENTS: The aim of the present study is to evaluate the additional value of systolic wall thickening to myocardial perfusion in diagnosing myocardial stunning in patients with angiography proven coronary artery disease. We selected 91 ischemic patients (82 males; mean age 59.7 ± 10.3) with CAD documented by angiography. Ischemia was defined as a summed difference score ≥5. All patients underwent a 2-day gated perfusion SPECT protocol. The patients received a dose of 740 MBq of 99mTc-tetrofosmin after stress and at rest. Treadmill maximal exercise tests were performed on all patients. RESULTS: The post-stress LVEF was significantly lower than rest LVEF (48.1% ± 10.3% vs 50.3% ± 10.7%; P = .0001). The wall thickening summed difference score was 4.44 ± 4.13 (P = .0001). At a multivariate regression analysis, only WT-SDS as independent variable was significantly correlated with myocardial ischemia (SDS). We also divided patients according to SDS in those with mild (SDS < 8) and severe (SDS ≥ 8) ischemia. WT-SDS, but not ∆LVEF, was significantly different between groups. CONCLUSIONS: WT-SDS, more than the depression in the global function (∆LVEF) of the left ventricle, correlates with the degree of ischemia and better identifies, when present, the stunning phenomenon.
Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço , Imagem do Acúmulo Cardíaco de Comporta , Miocárdio Atordoado/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Doença da Artéria Coronariana/complicações , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/etiologia , Valor Preditivo dos Testes , Volume SistólicoRESUMO
This study was conducted to evaluate the cardiac perfusion and function of patients with beta-thalassemia major (TM) using99mTc-MIBI cardiac gated single-photon-emission computed tomography (SPECT) and to compare the obtained indices with echocardiographic and hematological parameters. Patients with TM who were referred for regular blood transfusion and periodic checkup were included in this study. A questionnaire containing demographic and medical data was provided for all patients by an expert pediatrician. All of the patients were on Desferal chelation therapy and none of them had clinical signs of heart failure. Myocardial gated perfusion SPECT, echocardiography, and complete blood tests were performed for each patient. In total, 24 patients including 14 men (58.3%) and 10 women (41.7%) aged 15-36 years with a mean age of 24.3 ± 6.5 years' old were enrolled in this study. Myocardial perfusion scan (MPS) was normal in all patients. The mean value of the measured left ventricular ejection fraction (LVEF) was 58.88 ± 13.45%. There was no significant association between measured LVEF on scan and echocardiography (P > 0.05). In terms of hematological results, there was a significant association between the hemoglobin and ferritin level and the amount of blood transfusion (P = 0.02 and P= 0.00, respectively). According to the results of myocardial perfusion imaging (MPI), cardiac perfusion and LVEF were within normal limits in all asymptomatic patients. In the absence of any perfusion abnormality, the use of MPI in patients with asymptomatic beta-TM is not recommended for diagnosing myocardial ischemia.
RESUMO
The purpose of this study was to evaluate the diagnostic value of attenuation-corrected single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) on the inferior wall compared to uncorrected (NC) SPECT MPI between obese and nonobese patients. A total of 157 consecutive patients (122 males and 35 females, with median age: 57.4 ± 11 years) who underwent AC technetium 99m-methoxyisobutylisonitrile (AC Tc99m-sestamibi) SPECT MPI were included to the study. A hybrid SPECT and transmission computed tomography (CT) system was used for the diagnosis with 1-day protocol, and stress imaging was performed first. During attenuation correction (AC) processing on a Xeleris Workstation using Myovation cardiac software with ordered subset expectation maximization (OSEM), iterative reconstruction with attenuation correction (IRAC) and NC images filtered back projection (FBP) were used. For statistical purposes, P < 0.05 was considered significant. This study included 73 patients with body mass index (BMI) <30 and 84 patients with BMI ≥ 30. In patients with higher BMI, increased amount of both visual and semiquantitative attenuation of the inferior wall was detected. IRAC reconstruction corrects the diaphragm attenuation of the inferior wall better than FBP. AC with OSEM iterative reconstruction significantly improves the diagnostic value of stress-only SPECT MPI in patients with normal weight and those who are obese, but the improvements are significantly greater in obese patients. Stress-only SPECT imaging with AC provides shorter and lower radiation exposure.
RESUMO
UNLABELLED: A dedicated stationary cardiac single-photon emission computed tomography (SPECT) system with a novel segmented slant-hole collimator has been developed. The goal of this paper is to calibrate this new imaging geometry with a point source. METHODS: Unlike the commercially available dedicated cardiac SPECT systems, which are specialized and can be used only to image the heart, our proposed cardiac system is based on a conventional SPECT system but with a segmented slant-hole collimator replacing the collimator. For a dual-head SPECT system, 2 segmented collimators, each with 7 sections, are arranged in an L-shaped configuration such that they can produce a complete cardiac SPECT image with only one gantry position. A calibration method was developed to estimate the geometric parameters of each collimator section as well as the detector rotation radius, under the assumption that the point source location is calculated using the central-section data. With a point source located off the rotation axis, geometric parameters for each collimator section can be estimated independently. The parameters estimated individually are further improved by a joint objective function that uses all collimator sections simultaneously and incorporates the collimator symmetry information. RESULTS: Estimation results and images reconstructed from estimated parameters are presented for both simulated and real data acquired from a prototype collimator. The calibration accuracy was validated by computer simulations with an error of about 0.1° for the slant angles and about 1 mm for the rotation radius. Reconstructions of a heart-insert phantom did not show any image artifacts of inaccurate geometric parameters. CONCLUSION: Compared with the detector's intrinsic resolution, the estimation error is small and can be ignored. Therefore, the accuracy of the calibration is sufficient for cardiac SPECT imaging.
Assuntos
Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Calibragem , Simulação por ComputadorRESUMO
The autonomic nervous system plays an important role in the pathology of heart failure. The single-photon emission computed tomography tracer iodine-123-metaiodobenzylguanidine ((123) I-MIBG) can be used to investigate the activity of the predominant neurotransmitter of the sympathetic nervous system, norepinephrine. Also, positron emission tomography tracers are being developed for the same purpose. With (123) I-MIBG as a starting point, this brief review introduces the modalities used for cardiac sympathetic imaging.