1.
Am J Obstet Gynecol ; 230(4): 379.e1-379.e12, 2024 04.
Artigo em Inglês | MEDLINE | ID: mdl-38272284

RESUMO

BACKGROUND: Intrapartum cardiotocographic monitoring of fetal heart rate by abdominal external ultrasound transducer without simultaneous maternal heart rate recording has been associated with increased risk of early neonatal death and other asphyxia-related neonatal outcomes. It is unclear, however, whether this increase in risk is independently associated with fetal surveillance method or is attributable to other factors. OBJECTIVE: This study aimed to compare different fetal surveillance methods and their association with adverse short- and long-term fetal and neonatal outcomes in a large retrospective cohort of spontaneous term deliveries. STUDY DESIGN: Fetal heart rate and maternal heart rate patterns were recorded by cardiotocography during labor in spontaneous term singleton cephalic vaginal deliveries in the Hospital District of Helsinki and Uusimaa, Finland between October 1, 2005, and September 30, 2023. According to the method of cardiotocography monitoring at birth, the cohort was divided into the following 3 groups: women with ultrasound transducer, women with both ultrasound transducer and maternal heart rate transducer, and women with internal fetal scalp electrode. Umbilical artery pH and base excess values, low 1- and 5-minute Apgar scores, need for intubation and resuscitation, neonatal intensive care unit admission for asphyxia, neonatal encephalopathy, and early neonatal death were used as outcome variables. RESULTS: Among the 213,798 deliveries that met the inclusion criteria, the monitoring type was external ultrasound transducer in 81,559 (38.1%), both external ultrasound transducer and maternal heart rate recording in 62,268 (29.1%), and fetal scalp electrode in 69,971 (32.7%) cases, respectively. The rates of both neonatal encephalopathy (odds ratio, 1.48; 95% confidence interval, 1.08-2.02) and severe acidemia (umbilical artery pH <7.00 and/or umbilical artery base excess ≤-12.0 mmol/L) (odds ratio, 2.03; 95% confidence interval, 1.65-2.50) were higher in fetuses of women with ultrasound transducer alone compared with those of women with concurrent external fetal and maternal heart rate recording. Monitoring with ultrasound transducer alone was also associated with increased risk of neonatal intubation for resuscitation (odds ratio, 1.22; 95% confidence interval, 1.03-1.44). A greater risk of severe neonatal acidemia was observed both in the ultrasound transducer (odds ratio, 2.78; 95% confidence interval, 2.23-3.48) and concurrent ultrasound transducer and maternal heart rate recording (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) groups compared with those monitored with fetal scalp electrodes. No difference in risk of neonatal encephalopathy was found between newborns monitored with concurrent ultrasound transducer and maternal heart rate recording and those monitored with fetal scalp electrodes. CONCLUSION: The use of external ultrasound transducer monitoring of fetal heart rate without simultaneous maternal heart rate recording is associated with higher rates of neonatal encephalopathy and severe neonatal acidemia. We suggest that either external fetal heart rate monitoring with concurrent maternal heart rate recording or internal fetal scalp electrode be used routinely as a fetal surveillance tool in term deliveries.


Assuntos
Encefalopatias , Doenças do Recém-Nascido , Morte Perinatal , Gravidez , Recém-Nascido , Feminino , Humanos , Cardiotocografia/métodos , Estudos Retrospectivos , Asfixia , Frequência Cardíaca Fetal/fisiologia
2.
BJOG ; 131(2): 207-212, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37039242

RESUMO

OBJECTIVE: To investigate the significance of not meeting Dawes-Redman criteria on computerised cardiotocography in high-risk pregnancies. DESIGN: Retrospective observational study. SETTING: UK university hospital. POPULATION: High-risk pregnancies undergoing antenatal assessment. METHODS: We interrogated the database for records of computerised fetal heart rate assessment and pregnancy outcomes. MAIN OUTCOME MEASURES: Neonatal outcome and stillbirths. RESULTS: Excluding duplicate assessment in the same pregnancy, 14 025 records with complete information on the criteria of normality having been met and the outcome of the pregnancy were available. Criteria were not met for 907 records (6.46%). The gestational age of assessment was lower in the group not meeting criteria of normality. Overall, 32 stillbirths occurred in normally formed fetuses (2.28/1000). Stillbirths were more frequent in the group not meeting criteria (odds ratio [OR] 8.78, 95% CI 4.28-18.02). This finding persisted even after records with abnormally low short-term variation (STV) were excluded. The confidence intervals around the rate of stillbirth in the two groups overlapped beyond an STV of 8 ms. CONCLUSIONS: Approximately 1:16 pregnancies do not meet the criteria of normality. The criteria are not met more often at preterm gestation than at term. The risk of stillbirth was higher in the group not meeting criteria of normality, even if cases with low STV are excluded. Cases not meeting criteria should be followed up closely, unless the STV is ≥8 ms. Stillbirths still occurred in the group meeting criteria, but the rate was lower than in the general population.


Assuntos
Frequência Cardíaca Fetal , Natimorto , Recém-Nascido , Gravidez , Humanos , Feminino , Natimorto/epidemiologia , Frequência Cardíaca Fetal/fisiologia , Resultado da Gravidez/epidemiologia , Cardiotocografia , Idade Gestacional
3.
BJOG ; 131(4): 472-482, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37718558

RESUMO

OBJECTIVES: To investigate the association and the potential value of prelabour fetal heart rate short-term variability (STV) determined by computerised cardiotocography (cCTG) and maternal and fetal Doppler in predicting labour outcomes. DESIGN: Prospective cohort study. SETTING: The Prince of Wales Hospital, a tertiary maternity unit, in Hong Kong SAR. POPULATION: Women with a term singleton pregnancy in latent phase of labour or before labour induction were recruited during May 2019-November 2021. METHODS: Prelabour ultrasonographic assessment of fetal growth, Doppler velocimetry and prelabour cCTG monitoring including Dawes-Redman CTG analysis were registered shortly before induction of labour or during the latent phase of spontaneous labour. MAIN OUTCOME MEASURES: Umbilical cord arterial pH, emergency delivery due to pathological CTG during labour and neonatal intensive care unit (NICU)/special care baby unit (SCBU) admission. RESULTS: Of the 470 pregnant women invited to participate in the study, 440 women provided informed consent and a total of 400 participants were included for further analysis. Thirty-four (8.5%) participants underwent emergency delivery for pathological CTG during labour. A total of 6 (1.50%) and 148 (37.00%) newborns required NICU and SCBU admission, respectively. Middle cerebral artery pulsatility index (MCA-PI) and MCA-PI z-score were significantly lower in pregnancies that required emergency delivery for pathological CTG during labour compared with those that did not (1.23 [1.07-1.40] versus 1.40 [1.22-1.64], p = 0.002; and 0.55 ± 1.07 vs. 0.12 ± 1.06), p = 0.049]. This study demonstrated a weakly positive correlation between umbilical cord arterial pH and prelabour log10 STV (r = 0.107, p = 0.035) and the regression analyses revealed that the contributing factors for umbilical cord arterial pH were smoking (p = 0.006) and prelabour log10 STV (p = 0.025). CONCLUSIONS: In pregnant women admitted in latent phase of labour or for induction of labour at term, prelabour cCTG STV had a weakly positive association with umbilical cord arterial pH but was not predictive of emergency delivery due to pathological CTG during labour.


Assuntos
Cardiotocografia , Trabalho de Parto , Gravidez , Feminino , Recém-Nascido , Humanos , Estudos Prospectivos , Feto , Cuidado Pré-Natal
4.
Acta Obstet Gynecol Scand ; 103(3): 437-448, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38093630

RESUMO

INTRODUCTION: ST waveform analysis (STAN) was introduced as an adjunct to cardiotocography (CTG) to improve neonatal and maternal outcomes. The aim of the present study was to quantify the efficacy of STAN vs CTG and assess the quality of the evidence using GRADE. MATERIAL AND METHODS: We performed systematic literature searches to identify randomized controlled trials and assessed included studies for risk of bias. We performed meta-analyses, calculating pooled risk ratio (RR) or Peto odds ratio (OR). We also performed post hoc trial sequential analyses for selected outcomes to assess the risk of false-positive results and the need for additional studies. RESULTS: Nine randomized controlled trials including 28 729 women were included in the meta-analysis. There were no differences between the groups in operative deliveries for fetal distress (10.9 vs 11.1%; RR 0.96; 95% confidence interval [CI] 0.82-1.11). STAN was associated with a significantly lower rate of metabolic acidosis (0.45% vs 0.68%; Peto OR 0.66; 95% CI 0.48-0.90). Accordingly, 441 women need to be monitored with STAN instead of CTG alone to prevent one case of metabolic acidosis. Women allocated to STAN had a reduced risk of fetal blood sampling compared with women allocated to conventional CTG monitoring (12.5% vs 19.6%; RR 0.62; 95% CI 0.49-0.80). The quality of the evidence was high to moderate. CONCLUSIONS: Absolute effects of STAN were minor and the clinical significance of the observed reduction in metabolic acidosis is questioned. There is insufficient evidence to state that STAN as an adjunct to CTG leads to important clinical benefits compared with CTG alone.


Assuntos
Acidose , Cardiotocografia , Gravidez , Recém-Nascido , Feminino , Humanos , Cardiotocografia/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Sofrimento Fetal/diagnóstico , Eletrocardiografia/métodos , Acidose/diagnóstico , Acidose/prevenção & controle , Monitorização Fetal/métodos , Frequência Cardíaca Fetal
5.
BMC Pregnancy Childbirth ; 24(1): 136, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38355457

RESUMO

BACKGROUND: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor. MATERIAL AND METHODS: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively. RESULTS: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63). CONCLUSIONS: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.


Assuntos
Cardiotocografia , Hipóxia Fetal , Gravidez , Recém-Nascido , Feminino , Humanos , Cardiotocografia/métodos , Hipóxia Fetal/diagnóstico , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Estudos Transversais , Frequência Cardíaca Fetal
6.
Acta Obstet Gynecol Scand ; 103(1): 68-76, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890863

RESUMO

INTRODUCTION: It is a shortcoming of traditional cardiotocography (CTG) classification table formats that CTG traces are frequently classified differently by different users, resulting in poor interobserver agreements. A fast-and-frugal tree (FFTree) flow chart may help provide better concordance because it is straightforward and has clearly structured binary questions with understandable "yes" or "no" responses. The initial triage to determine whether a fetus is suitable for labor when utilizing fetal ECG ST analysis (STAN) is very important, since a fetus with restricted capacity to respond to hypoxic stress may not generate STAN events and therefore may become falsely negative. This study aimed to compare physiology-focused FFTree CTG interpretation with FIGO classification for assessing the suitability for STAN monitoring. MATERIAL AND METHODS: A retrospective study of 36 CTG traces with a high proportion of adverse outcomes (17/36) selected from a European multicenter study database. Eight experienced European obstetricians evaluated the initial 40 minutes of the CTG recordings and judged whether STAN was a suitable fetal surveillance method and whether intervention was indicated. The experts rated the CTGs using the FFTree and FIGO classifications at least 6 weeks apart. Interobserver agreements were calculated using proportions of agreement and Fleiss' kappa (κ). RESULTS: The proportions of agreement for "not suitable for STAN" were for FIGO 47% (95% confidence interval [CI] 42%-52%) and for FFTree 60% (95% CI 56-64), ie a significant difference; the corresponding figures for "yes, suitable" were 74% (95% CI 71-77) and 70% (95% CI 67-74). For "intervention needed" the figures were 52% (95% CI 47-56) vs 58% (95% CI 54-62) and for "expectant management" 74% (95% CI 71-77) vs 72% (95% CI 69-75). Fleiss' κ agreement on "suitability for STAN" was 0.50 (95% CI 0.44-0.56) for the FIGO classification and 0.57 (95% CI 0.51-0.63) for the FFTree classification; the corresponding figures for "intervention or expectancy" were 0.53 (95% CI 0.47-0.59) and 0.57 (95% CI 0.51-0.63). CONCLUSIONS: The proportion of agreement among expert obstetricians using the FFTree physiological approach was significantly higher compared with the traditional FIGO classification system in rejecting cases not suitable for STAN monitoring. That might be of importance to avoid false negative STAN recordings. Other agreement figures were similar. It remains to be shown whether the FFTree simplicity will benefit less experienced users and how it will work in real-world clinical scenarios.


Assuntos
Eletrocardiografia , Monitorização Fetal , Triagem , Feminino , Humanos , Gravidez , Cardiotocografia/métodos , Eletrocardiografia/métodos , Monitorização Fetal/métodos , Feto , Frequência Cardíaca Fetal/fisiologia , Variações Dependentes do Observador , Estudos Retrospectivos
7.
Acta Obstet Gynecol Scand ; 103(2): 276-285, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37983832

RESUMO

INTRODUCTION: A pregnancy can be evaluated as high-risk for the woman and/or the fetus based on medical history and on previous or ongoing pregnancy characteristics. Monitoring high-risk pregnancies is crucial for early detection of alarming features, enabling timely intervention to ensure optimal maternal and fetal health outcomes. Home-based telemonitoring (HBTM) is a marginally exploited opportunity in antenatal care. The aim of this study was to illuminate healthcare providers' and users' expectations and views about HBTM of maternal and fetal health in high-risk pregnancies before implementation. MATERIAL AND METHODS: To address diverse perspectives regarding HBTM of high-risk pregnancies, four different groups of experienced healthcare providers or users were interviewed (n = 21). Focus group interviews were conducted separately with midwives, obstetricians, and women who had previously experienced stillbirth. Six individual interviews were conducted with hospitalized women with ongoing high-risk pregnancies, representing potential candidates for HBTM. None of the participants had any previous experience with HBTM of pregnancies. The study is embedded in a social constructivist research paradigm. Interviews were analyzed using a thematic approach. RESULTS: The participants acknowledged the benefits and potentials of more active roles for both care recipients and providers in HBTM. Concerns were clearly addressed and articulated in the following themes: eligibility and ability of women, availability of midwives and obstetricians, empowerment and patient safety, and shared responsibility. All groups problematized issues crucial to maintaining a sense of safety for care recipients, and healthcare providers also addressed issues related to maintaining a sense of safety also for the care providers. Conditions for HBTM were understood in terms of optimal personalized training, individual assessment of eligibility, and empowerment of an active patient role. These conditions were linked to the importance of competent and experienced midwives and obstetricians operating the monitoring, as well as the availability and continuity of care provision. Maintenance of safety in HBTM in high-risk pregnancies was crucial, particularly so in situations involving emerging acute health issues. CONCLUSIONS: HBTM requires new, proactive roles among midwives, obstetricians, and monitored women, introducing a fine-tuned balance between personalized and standardized care to provide safe, optimal monitoring of high-risk pregnancies.


Assuntos
Amino Álcoois , Motivação , Gravidez de Alto Risco , Feminino , Gravidez , Humanos , Cuidado Pré-Natal , Pesquisa Qualitativa , Pessoal de Saúde
8.
Acta Obstet Gynecol Scand ; 103(10): 1910-1918, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39107951

RESUMO

Relative uteroplacental insufficiency of labor (RUPI-L) is a clinical condition that refers to alterations in the fetal oxygen "demand-supply" equation caused by the onset of regular uterine activity. The term RUPI-L indicates a condition of "relative" uteroplacental insufficiency which is relative to a specific stressful circumstance, such as the onset of regular uterine activity. RUPI-L may be more prevalent in fetuses in which the ratio between the fetal oxygen supply and demand is already slightly reduced, such as in cases of subclinical placental insufficiency, post-term pregnancies, gestational diabetes, and other similar conditions. Prior to the onset of regular uterine activity, fetuses with a RUPI-L may present with normal features on the cardiotocography. However, with the onset of uterine contractions, these fetuses start to manifest abnormal fetal heart rate patterns which reflect the attempt to maintain adequate perfusion to essential central organs during episodes of transient reduction in oxygenation. If labor is allowed to continue without an appropriate intervention, progressively more frequent, and stronger uterine contractions may result in a rapid deterioration of the fetal oxygenation leading to hypoxia and acidosis. In this Commentary, we introduce the term relative uteroplacental insufficiency of labor and highlight the pathophysiology, as well as the common features observed in the fetal heart rate tracing and clinical implications.


Assuntos
Insuficiência Placentária , Humanos , Feminino , Gravidez , Insuficiência Placentária/fisiopatologia , Frequência Cardíaca Fetal/fisiologia , Cardiotocografia , Contração Uterina/fisiologia , Complicações do Trabalho de Parto , Trabalho de Parto/fisiologia
9.
BMC Med Ethics ; 25(1): 6, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184595

RESUMO

BACKGROUND: Given that AI-driven decision support systems (AI-DSS) are intended to assist in medical decision making, it is essential that clinicians are willing to incorporate AI-DSS into their practice. This study takes as a case study the use of AI-driven cardiotography (CTG), a type of AI-DSS, in the context of intrapartum care. Focusing on the perspectives of obstetricians and midwives regarding the ethical and trust-related issues of incorporating AI-driven tools in their practice, this paper explores the conditions that AI-driven CTG must fulfill for clinicians to feel justified in incorporating this assistive technology into their decision-making processes regarding interventions in labor. METHODS: This study is based on semi-structured interviews conducted online with eight obstetricians and five midwives based in England. Participants were asked about their current decision-making processes about when to intervene in labor, how AI-driven CTG might enhance or disrupt this process, and what it would take for them to trust this kind of technology. Interviews were transcribed verbatim and analyzed with thematic analysis. NVivo software was used to organize thematic codes that recurred in interviews to identify the issues that mattered most to participants. Topics and themes that were repeated across interviews were identified to form the basis of the analysis and conclusions of this paper. RESULTS: There were four major themes that emerged from our interviews with obstetricians and midwives regarding the conditions that AI-driven CTG must fulfill: (1) the importance of accurate and efficient risk assessments; (2) the capacity for personalization and individualized medicine; (3) the lack of significance regarding the type of institution that develops technology; and (4) the need for transparency in the development process. CONCLUSIONS: Accuracy, efficiency, personalization abilities, transparency, and clear evidence that it can improve outcomes are conditions that clinicians deem necessary for AI-DSS to meet in order to be considered reliable and therefore worthy of being incorporated into the decision-making process. Importantly, healthcare professionals considered themselves as the epistemic authorities in the clinical context and the bearers of responsibility for delivering appropriate care. Therefore, what mattered to them was being able to evaluate the reliability of AI-DSS on their own terms, and have confidence in implementing them in their practice.


Assuntos
Tocologia , Humanos , Gravidez , Feminino , Obstetra , Reprodutibilidade dos Testes , Tomada de Decisão Clínica , Inteligência Artificial
10.
J Perinat Med ; 52(6): 597-603, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-38682857

RESUMO

OBJECTIVES: To compare characteristics of labor, cardiotocography traces, and maternal and neonatal outcomes, in a cohort of pregnancies at term complicated by maternal intrapartum pyrexia, with or without a histologic diagnosis of chorioamnionitis. METHODS: This is a retrospective case-control study including pregnancies at term with detection of maternal intrapartum pyrexia, delivered between January 2020 and June 2021. Cardiotocography traces were entirely evaluated, since admission till delivery, and classified according to the International Federation of Obstetrics and Gynecology (FIGO) guideline. Maternal and neonatal outcomes were also recorded as secondary outcomes. Placentas have been studied according to the Amniotic Fluid Infection Nosology Committee. RESULTS: Forty four patients met the inclusion criteria and were included in the study cohort. There was a significant association between the use of oxytocin augmentation in labor and the histologic diagnosis of chorioamnionitis. A significative recurrence of loss and/or absence of accelerations at the point of pyrexia was also documented in women with histological chorioamnionitis compared to the others. CONCLUSIONS: Chorioamnionitis appears to be associated with myometrial disfunction, as suggested by the increased use of oxytocin augmentation during active labor of women at term with intrapartum pyrexia and histologic diagnosis of chorioamnionitis.


Assuntos
Cardiotocografia , Corioamnionite , Febre , Humanos , Feminino , Corioamnionite/diagnóstico , Gravidez , Estudos de Casos e Controles , Cardiotocografia/métodos , Adulto , Estudos Retrospectivos , Febre/diagnóstico , Febre/etiologia , Ocitocina/administração & dosagem , Recém-Nascido
11.
BMC Med Inform Decis Mak ; 24(1): 19, 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38247009

RESUMO

BACKGROUND: In clinical medicine, fetal heart rate (FHR) monitoring using cardiotocography (CTG) is one of the most commonly used methods for assessing fetal acidosis. However, as the visual interpretation of CTG depends on the subjective judgment of the clinician, this has led to high inter-observer and intra-observer variability, making it necessary to introduce automated diagnostic techniques. METHODS: In this study, we propose a computer-aided diagnostic algorithm (Hybrid-FHR) for fetal acidosis to assist physicians in making objective decisions and taking timely interventions. Hybrid-FHR uses multi-modal features, including one-dimensional FHR signals and three types of expert features designed based on prior knowledge (morphological time domain, frequency domain, and nonlinear). To extract the spatiotemporal feature representation of one-dimensional FHR signals, we designed a multi-scale squeeze and excitation temporal convolutional network (SE-TCN) backbone model based on dilated causal convolution, which can effectively capture the long-term dependence of FHR signals by expanding the receptive field of each layer's convolution kernel while maintaining a relatively small parameter size. In addition, we proposed a cross-modal feature fusion (CMFF) method that uses multi-head attention mechanisms to explore the relationships between different modalities, obtaining more informative feature representations and improving diagnostic accuracy. RESULTS: Our ablation experiments show that the Hybrid-FHR outperforms traditional previous methods, with average accuracy, specificity, sensitivity, precision, and F1 score of 96.8, 97.5, 96, 97.5, and 96.7%, respectively. CONCLUSIONS: Our algorithm enables automated CTG analysis, assisting healthcare professionals in the early identification of fetal acidosis and the prompt implementation of interventions.


Assuntos
Acidose , Doenças Fetais , Feminino , Gravidez , Humanos , Acidose/diagnóstico , Algoritmos , Cardiotocografia , Tomada de Decisões , Inteligência Artificial
12.
J Physiol ; 601(10): 2017-2041, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37017488

RESUMO

Brief repeated fetal hypoxaemia during labour can trigger intrapartum decelerations of the fetal heart rate (FHR) via the peripheral chemoreflex or the direct effects of myocardial hypoxia, but the relative contribution of these two mechanisms and how this balance changes with evolving fetal compromise remain unknown. In the present study, chronically instrumented near-term fetal sheep received surgical vagotomy (n = 8) or sham vagotomy (control, n = 11) to disable the peripheral chemoreflex and unmask myocardial hypoxia. One-minute complete umbilical cord occlusions (UCOs) were performed every 2.5 min for 4 h or until arterial pressure fell below 20 mmHg. Hypotension and severe acidaemia developed progressively after 65.7 ± 7.2 UCOs in control fetuses and 49.5 ± 7.8 UCOs after vagotomy. Vagotomy was associated with faster development of metabolic acidaemia and faster impairment of arterial pressure during UCOs without impairing centralization of blood flow or neurophysiological adaptation to UCOs. During the first half of the UCO series, before severe hypotension developed, vagotomy was associated with a marked increase in FHR during UCOs. After the onset of evolving severe hypotension, FHR fell faster in control fetuses during the first 20 s of UCOs, but FHR during the final 40 s of UCOs became progressively more similar between groups, with no difference in the nadir of decelerations. In conclusion, FHR decelerations were initiated and sustained by the peripheral chemoreflex at a time when fetuses were able to maintain arterial pressure. After the onset of evolving hypotension and acidaemia, the peripheral chemoreflex continued to initiate decelerations, but myocardial hypoxia became progressively more important in sustaining and deepening decelerations. KEY POINTS: Brief repeated hypoxaemia during labour can trigger fetal heart rate decelerations by either the peripheral chemoreflex or myocardial hypoxia, but how this balance changes with fetal compromise is unknown. Reflex control of fetal heart rate was disabled by vagotomy to unmask the effects of myocardial hypoxia in chronically instrumented fetal sheep. Fetuses were then subjected to repeated brief hypoxaemia consistent with the rates of uterine contractions during labour. We show that the peripheral chemoreflex controls brief decelerations in their entirety at a time when fetuses were able to maintain normal or increased arterial pressure. The peripheral chemoreflex still initiated decelerations even after the onset of evolving hypotension and acidaemia, but myocardial hypoxia made an increasing contribution to sustain and deepen decelerations.


Assuntos
Acidose , Hipotensão , Isquemia Miocárdica , Feminino , Ovinos , Gravidez , Animais , Humanos , Desaceleração , Frequência Cardíaca Fetal/fisiologia , Cordão Umbilical/irrigação sanguínea , Feto , Hipóxia , Hipóxia Fetal
13.
Am J Obstet Gynecol ; 228(5S): S1117-S1128, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-34801443

RESUMO

Uterine contractions during labor and engagement of the fetus in the birth canal can compress the fetal head. Its impact on the fetus is unclear and still controversial. In this integrative physiological review, we highlight evidence that decelerations are uncommonly associated with fetal head compression. Next, the fetus has an impressive ability to adapt to increased intracranial pressure through activation of the intracranial baroreflex, such that fetal cerebral perfusion is well-maintained during labor, except in the setting of prolonged systemic hypoxemia leading to secondary cardiovascular compromise. Thus, when it occurs, fetal head compression is not necessarily benign but does not seem to be a common contributor to intrapartum decelerations. Finally, the intracranial baroreflex and the peripheral chemoreflex (the response to acute hypoxemia) have overlapping efferent effects. We propose the hypothesis that these reflexes may work synergistically to promote fetal adaptation to labor.


Assuntos
Desaceleração , Trabalho de Parto , Gravidez , Feminino , Humanos , Parto , Trabalho de Parto/fisiologia , Hipóxia , Feto/fisiologia , Frequência Cardíaca Fetal/fisiologia , Cardiotocografia
14.
Am J Obstet Gynecol ; 229(4): 377-387, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37044237

RESUMO

OBJECTIVE: This study aimed to evaluate the rate of adverse neonatal or maternal outcomes in parturients with fetal heart rate tracings categorized as I, II or, III within the last 30 to 120 minutes of delivery. DATA SOURCES: The MEDLINE Ovid, Scopus, Embase, CINAHL, and Clinicaltrials.gov databases were searched electronically up to May 2022, using combinations of the relevant medical subject heading terms, keywords, and word variants that were considered suitable for the topic. STUDY ELIGIBILITY CRITERIA: Only observational studies of term infants reporting outcomes of interest with category I, II, or III fetal heart rate tracings were included. STUDY APPRAISAL AND SYNTHESIS METHODS: The coprimary outcome was the rate of either Apgar score <7 at 5 minutes or umbilical artery pH <7.00. Secondary outcomes were divided into neonatal and maternal adverse outcomes. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale. Random-effect meta-analyses of proportions were used to estimate the pooled rates of each categorical outcome in fetal heart rate tracing category I, II, and III patterns, and random-effect head-to-head meta-analyses were used to directly compare fetal heart rate tracings category I vs II and fetal heart rate tracing category II vs III, expressing the results as summary odds ratio or as mean differences with relative 95% confidence intervals. RESULTS: Of the 671 articles reviewed, 3 publications met the inclusion criteria. Among them were 47,648 singletons at ≥37 weeks' gestation. Fetal heart rate tracings in the last 30 to 120 minutes before delivery were characterized in the following manner: 27.0% of deliveries had category I tracings, 72.9% had category II tracings, and 0.1% had category III tracings. A single study, which was rated to be of poor quality, contributed 82.1% of the data and it did not provide any data for category III fetal heart rate tracings. When compared with category I fetal heart rate tracings (0.74%), the incidence of an Apgar score <7 at 5 minutes were significantly higher among deliveries with category II fetal heart rate tracings (1.51%) (odds ratio, 1.56; 95% confidence interval, 1.23-1.99) and among those with category III tracings (14.63%) (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). When compared with category II tracings, category III tracings also had a significantly higher likelihood of a low Apgar score at 5 minutes (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). The incidence of an umbilical artery pH <7.00 were similar among those with category I and those with category II tracings (0.08% vs 0.24%; odds ratio, 2.85; 95% confidence interval, 0.41-19.55). When compared with category I tracings, the incidence of an umbilical artery pH <7.00 was significantly more common among those with category III tracings (31.04%; odds ratio, 161.56; 95% confidence interval, 25.18-1036.42); likewise, when compared with those with category II tracings, those with category III tracings had a significantly higher likelihood of having an umbilical artery pH <7.00 (odds ratio, 42.29; 95% confidence interval, 14.29-125.10). Hypoxic-ischemic encephalopathy occurred with similar frequency among those with categories I and those with category II tracings (0 vs 0.81%; odds ratio, 5.86; 95% confidence interval, 0.75-45.89) but was significantly more common among those with category III tracings (0 vs 18.97%; odds ratio, 61.43; 95% confidence interval, 7.49-503.50). Cesarean delivery occurred with similar frequency among those with category I (13.41%) and those with category II tracings (11.92%) (odds ratio, 0.87; 95% confidence interval, 0.72-1.05) but was significantly more common among those with with category III tracings (14.28%) (odds ratio, 3.97; 95% confidence interval, 1.62-9.75). When compared with those with category II tracings, cesarean delivery was more common among those with category III tracings (odds ratio, 4.55; 95% confidence interval, 1.88-11.01). CONCLUSION: Although the incidence of an Apgar score <7 at 5 minutes and umbilical artery pH <7.00 increased significantly with increasing fetal heart rate tracing category, about 98% of newborns with category II tracings do not have these adverse outcomes. The 3-tiered fetal heart rate tracing interpretation system provides an approximate but imprecise measurement of neonatal prognosis.


Assuntos
Frequência Cardíaca Fetal , Doenças do Recém-Nascido , Gravidez , Lactente , Feminino , Recém-Nascido , Humanos , Cardiotocografia/métodos , Cesárea , Doenças do Recém-Nascido/epidemiologia , Prognóstico
15.
Am J Obstet Gynecol ; 228(6): 645-656, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37270260

RESUMO

Any acute and profound reduction in fetal oxygenation increases the risk of anaerobic metabolism in the fetal myocardium and, hence, the risk of lactic acidosis. On the contrary, in a gradually evolving hypoxic stress, there is sufficient time to mount a catecholamine-mediated increase in the fetal heart rate to increase the cardiac output and redistribute oxygenated blood to maintain an aerobic metabolism in the fetal central organs. When the hypoxic stress is sudden, profound, and sustained, it is not possible to continue to maintain central organ perfusion by peripheral vasoconstriction and centralization. In case of acute deprivation of oxygen, the immediate chemoreflex response via the vagus nerve helps reduce fetal myocardial workload by a sudden drop of the baseline fetal heart rate. If this drop in the fetal heart rate continues for >2 minutes (American College of Obstetricians and Gynecologists' guideline) or 3 minutes (National Institute for Health and Care Excellence or physiological guideline), it is termed a prolonged deceleration, which occurs because of myocardial hypoxia, after the initial chemoreflex. The revised International Federation of Gynecology and Obstetrics guideline (2015) considers the prolonged deceleration to be a "pathologic" feature after 5 minutes. Acute intrapartum accidents (placental abruption, umbilical cord prolapse, and uterine rupture) should be excluded immediately, and if they are present, an urgent birth should be accomplished. If a reversible cause is found (maternal hypotension, uterine hypertonus or hyperstimulation, and sustained umbilical cord compression), immediate conservative measures (also called intrauterine fetal resuscitation) should be undertaken to reverse the underlying cause. In reversible causes of acute hypoxia, if the fetal heart rate variability is normal before the onset of deceleration, and normal within the first 3 minutes of the prolonged deceleration, then there is an increased likelihood of recovery of the fetal heart rate to its antecedent baseline within 9 minutes with the reversal of the underlying cause of acute and profound reduction in fetal oxygenation. The continuation of the prolonged deceleration for >10 minutes is termed "terminal bradycardia," and this increases the risk of hypoxic-ischemic injury to the deep gray matter of the brain (the thalami and the basal ganglia), predisposing to dyskinetic cerebral palsy. Therefore, any acute fetal hypoxia, which manifests as a prolonged deceleration on the fetal heart rate tracing, should be considered an intrapartum emergency requiring an immediate intervention to optimize perinatal outcome. In uterine hypertonus or hyperstimulation, if the prolonged deceleration persists despite stopping the uterotonic agent, then acute tocolysis is recommended to rapidly restore fetal oxygenation. Regular clinical audit of the management of acute hypoxia, including the "the onset of bradycardia to delivery interval," may help identify organizational and system issues, which may contribute to poor perinatal outcomes.


Assuntos
Bradicardia , Frequência Cardíaca Fetal , Gravidez , Feminino , Humanos , Bradicardia/terapia , Frequência Cardíaca Fetal/fisiologia , Desaceleração , Placenta , Hipóxia Fetal/terapia
16.
Am J Obstet Gynecol ; 228(5S): S1129-S1143, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37164491

RESUMO

Electronic fetal monitoring, particularly in the form of cardiotocography, forms the centerpiece of labor management. Initially successfully designed for stillbirth prevention, there was hope to also include prediction and prevention of fetal acidosis and its sequelae. With the routine use of electronic fetal monitoring, the cesarean delivery rate increased from <5% in the 1970s to >30% at present. Most at-risk cases produced healthy babies, resulting in part from considerable confusion as to the differences between diagnostic and screening tests. Electronic fetal monitoring is clearly a screening test. Multiple attempts have aimed at enhancing its ability to accurately distinguish babies at risk of in utero injury from those who are not and to do this in a timely manner so that appropriate intervention can be performed. Even key electronic fetal monitoring opinion leaders admit that this goal has yet to be achieved. Our group has developed a modified approach called the "Fetal Reserve Index" that contextualizes the findings of electronic fetal monitoring by formally including the presence of maternal, fetal, and obstetrical risk factors and increased uterine contraction frequencies and breaking up the tracing into 4 quantifiable components (heart rate, variability, decelerations, and accelerations). The result is a quantitative 8-point metric, with each variable being weighted equally in version 1.0. In multiple previously published refereed papers, we have shown that in head-to-head studies comparing the fetal reserve index with the American College of Obstetricians and Gynecologists' fetal heart rate categories, the fetal reserve index more accurately identifies babies born with cerebral palsy and could also reduce the rates of emergency cesarean delivery and vaginal operative deliveries. We found that the fetal reserve index scores and fetal pH and base excess actually begin to fall earlier in the first stage of labor than was commonly appreciated, and the fetal reserve index provides a good surrogate for pH and base excess values. Finally, the last fetal reserve index score before delivery combined with early analysis of neonatal heart rate and acid/base balance shows that the period of risk for neonatal neurologic impairment can continue for the first 30 minutes of life and requires much closer neonatal observation than is currently being done.


Assuntos
Cardiotocografia , Trabalho de Parto , Recém-Nascido , Feminino , Gravidez , Humanos , Cardiotocografia/métodos , Parto Obstétrico/métodos , Cesárea , Cuidado Pré-Natal , Frequência Cardíaca Fetal/fisiologia , Monitorização Fetal
17.
Am J Obstet Gynecol ; 228(6): 622-644, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37270259

RESUMO

The onset of regular, strong, and progressive uterine contractions may result in both mechanical (compression of the fetal head and/or umbilical cord) and hypoxic (repetitive and sustained compression of the umbilical cord or reduction in uteroplacental oxygenation) stresses to a human fetus. Most fetuses are able to mount effective compensatory responses to avoid hypoxic-ischemic encephalopathy and perinatal death secondary to the onset of anaerobic metabolism within the myocardium, culminating in myocardial lactic acidosis. In addition, the presence of fetal hemoglobin, which has a higher affinity for oxygen even at low partial pressures of oxygen than the adult hemoglobin, especially increased amounts of fetal hemoglobin (ie, 180-220 g/L in fetuses vs 110-140 g/L in adults), helps the fetus to withstand hypoxic stresses during labor. Different national and international guidelines are currently being used for intrapartum fetal heart rate interpretation. These traditional classification systems for fetal heart rate interpretation during labor are based on grouping certain features of fetal heart rate (ie, baseline fetal heart rate, baseline variability, accelerations, and decelerations) into different categories (eg, category I, II, and III tracings, "normal, suspicious, and pathologic" or "normal, intermediary, and abnormal"). These guidelines differ from each other because of the features included within different categories and because of their arbitrary time limits stipulated for each feature to warrant an obstetrical intervention. This approach fails to individualize care because the "ranges of normality" for stipulated parameters apply to the population of human fetuses and not to the individual fetus in question. Moreover, different fetuses have different reserves and compensatory responses and different intrauterine environments (presence of meconium staining of amniotic fluid, intrauterine inflammation, and the nature of uterine activity). Pathophysiological interpretation of fetal heart rate tracing is based on the application of the knowledge of fetal responses to intrapartum mechanical and/or hypoxic stress in clinical practice. Both experimental animal studies and observational human studies suggest that, just like adults undertaking a treadmill exercise, human fetuses show predictable compensatory responses to a progressively evolving intrapartum hypoxic stress. These responses include the onset of decelerations to reduce myocardial workload and preserve aerobic metabolism, loss of accelerations to abolish nonessential somatic body movements, and catecholamine-mediated increases in the baseline fetal heart rate and effective redistribution and centralization to protect the fetal central organs (ie, the heart, brain, and adrenal glands), which are essential for intrauterine survival. Moreover, it is essential to incorporate the clinical context (progress of labor, fetal size and reserves, presence of meconium staining of amniotic fluid and intrauterine inflammation, and fetal anemia) and understand the features suggestive of fetal compromise in nonhypoxic pathways (eg, chorioamnionitis and fetomaternal hemorrhage). It is important to appreciate that the timely recognition of the speed of onset of intrapartum hypoxia (ie, acute, subacute, and gradually evolving) and preexisting uteroplacental insufficiency (ie, chronic hypoxia) on fetal heart rate tracing is crucial to improve perinatal outcomes.


Assuntos
Cardiotocografia , Doenças do Recém-Nascido , Adulto , Animais , Feminino , Humanos , Gravidez , Hemoglobina Fetal , Frequência Cardíaca Fetal/fisiologia , Hipóxia , Inflamação , Oxigênio
18.
BJOG ; 130(11): 1412-1420, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37186444

RESUMO

OBJECTIVE: To assess the association between undetected small-for-gestational age (SGA) fetuses and abnormal admission cardiotocography (admCTG) in a low-risk population. DESIGN: An observational study. SETTING: Four hospitals in Stockholm-Gotland, Sweden. SAMPLE: A cohort of 127 461 deliveries between 1 February 2012 and 15 June 2020. METHODS: This cohort was linked to the Swedish Neonatal Quality Register. Pregnancies were designated as high or low risk at the time of admission to the labour ward according to pre-defined risk measures. SGA was defined as a birthweight at or below the tenth centile and at or below the third centile for gestational age. MAIN OUTCOME MEASURES: The main outcome was the proportion of undetected SGA by admCTG (normal or abnormal). The secondary outcome was a composite severe adverse neonatal outcome for fetuses born less than 6 hours after admission (Apgar score <4 at 5 minutes, hypoxic-ischaemic encephalopathy grade of 2-3, neonatal seizures and neonatal death). RESULTS: The rate of abnormal admCTG was 4.9%. The proportion of SGA at or below the tenth centile was higher in the abnormal admCTG group than in the normal admCTG group, 18.6% versus 9.7% (odds ratio 2.1, 95% CI 1.9-2.3). Abnormal admCTG and SGA (≤10th) was associated with a more than 20-fold increased risk of an adverse outcome compared with normal admCTG and non-SGA (adjusted odds ratio 23.7, 95% CI 9.8-57.3). The latter had a risk of 1/2000 of an adverse outcome. CONCLUSIONS: In this low-risk population, undetected SGA fetuses were more prone to having abnormal admCTG and had a substantially higher risk of severe adverse neonatal outcomes.

19.
BJOG ; 130(8): 881-890, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36808862

RESUMO

OBJECTIVE: Deceleration area (DA) and capacity (DC) of the fetal heart rate can help predict risk of intrapartum fetal compromise. However, their predictive value in higher risk pregnancies is unclear. We investigated whether they can predict the onset of hypotension during brief hypoxaemia repeated at a rate consistent with early labour in fetal sheep with pre-existing hypoxaemia. DESIGN: Prospective, controlled study. SETTING: Laboratory. SAMPLE: Chronically instrumented, unanaesthetised near-term fetal sheep. METHODS: One-minute complete umbilical cord occlusions (UCOs) were performed every 5 minutes in fetal sheep with baseline pa O2 <17 mmHg (hypoxaemic, n = 8) and >17 mmHg (normoxic, n = 11) for 4 hours or until arterial pressure fell <20 mmHg. MAIN OUTCOME MEASURES: DA, DC and arterial pressure. RESULTS: Normoxic fetuses showed effective cardiovascular adaptation without hypotension and mild acidaemia (lowest arterial pressure 40.7 ± 2.8 mmHg, pH 7.35 ± 0.03). Hypoxaemic fetuses developed hypotension (lowest arterial pressure 20.8 ± 1.9 mmHg, P < 0.001) and acidaemia (final pH 7.07 ± 0.05). In hypoxaemic fetuses, decelerations showed faster falls in FHR over the first 40 seconds of UCOs but the final deceleration depth was not different to normoxic fetuses. DC was modestly higher in hypoxaemic fetuses during the penultimate (P = 0.04) and final (P = 0.012) 20 minutes of UCOs. DA was not different between groups. CONCLUSION: Chronically hypoxaemic fetuses had early onset of cardiovascular compromise during labour-like brief repeated UCOs. DA was unable to identify developing hypotension in this setting, while DC only showed modest differences between groups. These findings highlight that DA and DC thresholds need to be adjusted for antenatal risk factors, potentially limiting their clinical utility.


Assuntos
Acidose , Hipotensão , Animais , Feminino , Gravidez , Acidose/etiologia , Feto , Frequência Cardíaca Fetal/fisiologia , Hipotensão/complicações , Hipóxia/complicações , Estudos Prospectivos , Ovinos , Cordão Umbilical/irrigação sanguínea
20.
Ultrasound Obstet Gynecol ; 61(6): 758-764, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36864543

RESUMO

OBJECTIVES: To compare short-term variation (STV) outputs from a novel self-applied non-invasive fetal electrocardiography (NIFECG) device with those obtained on computerized cardiotocography (cCTG). Technological and algorithmic limitations and mitigation strategies were also evaluated. METHODS: This was a prospective cohort study of women with a singleton pregnancy over 28 + 0 weeks' gestation attending a tertiary London hospital for cCTG assessment between June 2021 and June 2022. Women underwent concurrent monitoring with both NIFECG and cCTG for up to 1 h. Postprocessing of NIFECG data using various filtering methods produced NIFECG-STV (eSTV) values, which were compared with cCTG-STV (cSTV) outputs. Linear correlation, mean bias, precision and limits of agreement were assessed for STV derived by the different methods of computation and mathematical correction. RESULTS: Overall, 306 concurrent NIFECG and cCTG traces were collected from 285 women. Fully filtered eSTV was correlated very strongly with cSTV (r = 0.911, P < 0.001), but generated results only in 142/306 (46.4%) 1-h traces owing to the removal of traces with lower-quality signals. Partial filtering generated more eSTV data (98.4%), but with a weak correlation with cSTV (r = 0.337, P < 0.001). The difference in STV between the monitors (eSTV - cSTV) increased with signal loss; in traces with > 60% signal loss, the values became highly discrepant. Removal of traces with > 60% signal loss resulted in a stronger correlation with cSTV, while still generating eSTV results for 65% of traces. Correcting these remaining eSTV values for signal loss using linear regression analysis further improved correlation with cSTV (r = 0.839, P < 0.001). CONCLUSIONS: The discrepancy between STV computed by NIFECG and cCTG necessitates signal filtering, exclusion of poor-quality traces and eSTV correction. This study demonstrates that, with such correction, NIFECG is able to produce STV values that are strongly correlated with those of cCTG. This evidence base for NIFECG monitoring and interpretation is a promising step forward in the development of safe and effective at-home fetal heart-rate monitoring. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Cardiotocografia , Monitorização Fetal , Gravidez , Humanos , Feminino , Cardiotocografia/métodos , Estudos Prospectivos , Feto , Eletrocardiografia , Frequência Cardíaca Fetal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA