Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
J Occup Environ Hyg ; 16(3): 242-249, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30620243

RESUMO

A person-wearable dust monitor that provides nearly real-time, mass-based readings of respirable dust was developed for use in underground coal mines. This personal dust monitor (PDM) combined dust sampling instrumentation with a cap lamp (and battery) into one belt-wearable unit, with the air inlet mounted on the cap lamp. However, obsolescence of belt-carried cap lamp and batteries in coal mining ensued and led end users to request that the cap lamp and battery be removed from the PDM. Removal of these components necessitated the design of a new air inlet to be worn on the miner's lapel. The revised inlet was tested for dust collection equivalency against the original cap-mounted inlet design. Using calculated inlet respirable fractions and measured dust mass collection, the performance of the two inlets is shown to be similar. The new inlet requires a 1.02 factor for converting dust masses obtained from it to equivalent masses collected from the original inlet.


Assuntos
Poluentes Ocupacionais do Ar/análise , Carvão Mineral , Poeira/análise , Monitoramento Ambiental/instrumentação , Exposição por Inalação/análise , Exposição Ocupacional/análise , Minas de Carvão , Desenho de Equipamento , Humanos , Dispositivos Eletrônicos Vestíveis
2.
J Occup Environ Hyg ; 13(2): 148-58, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26513395

RESUMO

In the U.S., most industrial hygiene practitioners continue to rely on the closed-face cassette (CFC) to assess worker exposures to hazardous dusts, primarily because ease of use, cost, and familiarity. However, mass concentrations measured with this classic sampler underestimate exposures to larger particles throughout the inhalable particulate mass (IPM) size range (up to aerodynamic diameters of 100 µm). To investigate whether the current 37-mm inlet cap can be redesigned to better meet the IPM sampling criterion, computational fluid dynamics (CFD) models were developed, and particle sampling efficiencies associated with various modifications to the CFC inlet cap were determined. Simulations of fluid flow (standard k-epsilon turbulent model) and particle transport (laminar trajectories, 1-116 µm) were conducted using sampling flow rates of 10 L min(-1) in slow moving air (0.2 m s(-1)) in the facing-the-wind orientation. Combinations of seven inlet shapes and three inlet diameters were evaluated as candidates to replace the current 37-mm inlet cap. For a given inlet geometry, differences in sampler efficiency between inlet diameters averaged less than 1% for particles through 100 µm, but the largest opening was found to increase the efficiency for the 116 µm particles by 14% for the flat inlet cap. A substantial reduction in sampler efficiency was identified for sampler inlets with side walls extending beyond the dimension of the external lip of the current 37-mm CFC. The inlet cap based on the 37-mm CFC dimensions with an expanded 15-mm entry provided the best agreement with facing-the-wind human aspiration efficiency. The sampler efficiency was increased with a flat entry or with a thin central lip adjacent to the new enlarged entry. This work provides a substantial body of sampling efficiency estimates as a function of particle size and inlet geometry for personal aerosol samplers.


Assuntos
Poluentes Ocupacionais do Ar/análise , Desenho de Equipamento , Hidrodinâmica , Tamanho da Partícula , Movimentos do Ar , Poeira , Monitoramento Ambiental/métodos , Exposição por Inalação/análise , Modelos Teóricos , Estados Unidos
3.
Ann Occup Hyg ; 59(6): 788-96, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25808693

RESUMO

A field study was carried out in order to derive a factor for the conversion of historic worker exposure data on airborne beryllium (Be) obtained by sampling according to the 37-mm closed faced filter cassette (CFC) 'total' particulate method into exposure concentration values to be expected when sampling using the 'Gesamtstaubprobenahmesystem' (GSP) inhalable sampling convention. Workplaces selected to represent the different copper Be work processing operations that typically occur in Germany and the EU were monitored revealing a broad spectrum of prevailing Be size distributions. In total, 39 personal samples were taken using a 37-mm CFC and a GSP worn side by side for simultaneous collection of the 'total' dust and the inhalable particulates, respectively. In addition, 20 static general area measurements were carried out using GSP, CFC, and Respicon samplers in parallel, the latter one providing information on the extra-thoracic fraction of the workplace aerosol. The study showed that there is a linear relationship between the concentrations measured with the CFC and those measured with the GSP sampler. The geometric mean value of the ratios of time-weighted average concentrations determined from GSP and CFC samples of all personal samples was 2.88. The individual values covered a range between 1 and 17 related to differences in size distributions of the Be-containing particulates. This was supported by the area measurements showing that the conversion factor increases with increasing values of the extra-thoracic fraction covering a range between 0 and 79%.


Assuntos
Aerossóis/análise , Berílio/análise , Poeira/análise , Exposição por Inalação/análise , Exposição Ocupacional/análise , Local de Trabalho , Monitoramento Ambiental/métodos , Alemanha , Humanos , Tamanho da Partícula , Dispositivos de Proteção Respiratória/estatística & dados numéricos
4.
J Occup Environ Hyg ; 12(4): 245-55, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25438035

RESUMO

Computational fluid dynamics (CFD) modeling was performed to investigate the aspiration efficiency of the human head in low velocities to examine whether the current inhaled particulate mass (IPM) sampling criterion matches the aspiration efficiency of an inhaling human in airflows common to worker exposures. Data from both mouth and nose inhalation, averaged to assess omnidirectional aspiration efficiencies, were compiled and used to generate a unifying model to relate particle size to aspiration efficiency of the human head. Multiple linear regression was used to generate an empirical model to estimate human aspiration efficiency and included particle size as well as breathing and freestream velocities as dependent variables. A new set of simulated mouth and nose breathing aspiration efficiencies was generated and used to test the fit of empirical models. Further, empirical relationships between test conditions and CFD estimates of aspiration were compared to experimental data from mannequin studies, including both calm-air and ultra-low velocity experiments. While a linear relationship between particle size and aspiration is reported in calm air studies, the CFD simulations identified a more reasonable fit using the square of particle aerodynamic diameter, which better addressed the shape of the efficiency curve's decline toward zero for large particles. The ultimate goal of this work was to develop an empirical model that incorporates real-world variations in critical factors associated with particle aspiration to inform low-velocity modifications to the inhalable particle sampling criterion.


Assuntos
Poluentes Ocupacionais do Ar/análise , Simulação por Computador , Exposição por Inalação/estatística & dados numéricos , Inalação , Movimentos do Ar , Monitoramento Ambiental/métodos , Humanos , Hidrodinâmica , Exposição por Inalação/análise , Modelos Lineares , Boca , Nariz , Tamanho da Partícula
5.
Ann Occup Hyg ; 58(5): 625-45, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24665111

RESUMO

An understanding of how particles are inhaled into the human nose is important for developing samplers that measure biologically relevant estimates of exposure in the workplace. While previous computational mouth-breathing investigations of particle aspiration have been conducted in slow moving air, nose breathing still required exploration. Computational fluid dynamics was used to estimate nasal aspiration efficiency for an inhaling humanoid form in low velocity wind speeds (0.1-0.4 m s(-1)). Breathing was simplified as continuous inhalation through the nose. Fluid flow and particle trajectories were simulated over seven discrete orientations relative to the oncoming wind (0, 15, 30, 60, 90, 135, 180°). Sensitivities of the model simplification and methods were assessed, particularly the placement of the recessed nostril surface and the size of the nose. Simulations identified higher aspiration (13% on average) when compared to published experimental wind tunnel data. Significant differences in aspiration were identified between nose geometry, with the smaller nose aspirating an average of 8.6% more than the larger nose. Differences in fluid flow solution methods accounted for 2% average differences, on the order of methodological uncertainty. Similar trends to mouth-breathing simulations were observed including increasing aspiration efficiency with decreasing freestream velocity and decreasing aspiration with increasing rotation away from the oncoming wind. These models indicate nasal aspiration in slow moving air occurs only for particles <100 µm.


Assuntos
Poluentes Ocupacionais do Ar/análise , Simulação por Computador , Hidrodinâmica , Exposição por Inalação/análise , Inalação , Movimentos do Ar , Monitoramento Ambiental/métodos , Humanos , Manequins , Nariz
6.
Ann Occup Hyg ; 57(8): 1054-64, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23792971

RESUMO

Intersampler field comparison of Respicon(®), 25-mm closed-face 'total dust' cassette (CFC), and IOM inhalable aerosol sampler was conducted in pot rooms at seven aluminium smelters. The aerosol mass and water-soluble fluoride were selected as airborne contaminants for the comparisons. The aerosol masses of 889 sample pairs of IOM and Respicon(®) inhalable aerosol sub-fraction, 165 of IOM and 25-mm CFC, and 194 of CFC and Respicon(®) thoracic aerosol sub-fraction were compared. The number of sample pairs for the comparison of water-soluble fluoride was 906, 170, and 195, respectively. The geometric mean aerosol mass collected with the inhalable Respicon(®) was 2.91 mg m(-3) compared with 3.38 mg m(-3) with the IOM. The overall ratio between IOM and Respicon(®) inhalable sub-fraction was 1.16 [95% confidence interval (CI) = 1.11-1.21] for aerosol mass and 1.13 (95% CI = 1.08-1.18) for water-soluble fluoride. The results indicate that Respicon(®) undersampled the aerosol mass and water-soluble fluoride in the inhalable sub-fraction compared with the IOM. The results indicated undersampling of the Respicon(®) at mass concentrations higher than 1.35 mg m(-3) and oversampling at lower mass concentrations. The overall ratio between aerosol mass collected with IOM and CFC was 4.19 (95% CI = 3.79-4.64) and 1.61 (95% CI = 1.51-1.72) for water-soluble fluoride. Thus, for this industry, a correction factor of 4.2 is suggested for the conversion of CFC to inhalable aerosol masses and a conversion factor of 1.6 for water-soluble fluoride if wall deposits in the CFC are included. CFC and thoracic Respicon(®) collected similar aerosol masses (ratio = 1.04; 95% CI = 0.97-1.12), whereas the ratio was 1.19 (95% CI = 1.11-1.28) for water-soluble fluoride. The variability of the exposure is substantial; thus, large data sets are required in sampler performance field comparisons.


Assuntos
Aerossóis/análise , Monitoramento Ambiental/instrumentação , Exposição por Inalação/análise , Exposição Ocupacional/análise , Alumínio , Humanos , Indústrias/métodos , Metalurgia , Noruega , Material Particulado/análise
7.
Artigo em Inglês | MEDLINE | ID: mdl-37444055

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic has not only brought considerable and permanent changes to economies and healthcare systems, but it has also greatly changed the habits of almost the entire society. During the lockdowns, people were forced to stay in their dwellings, which served as a catalyst for the initiation of a survey on the estimation of the metallic element content in residential indoor dust in different parts of Latvia. This article presents the study results obtained through the analysis of collected dust samples from 46 dwellings, both in the capital of Latvia, Riga, and in smaller cities. Two methods were employed for indoor dust collection: vacuum sampling and manual sampling with a brush and plastic spatula. After microwave-assisted acid extraction, the samples were analyzed using inductively coupled plasma mass spectrometry (ICP-MS) in terms of the major (Na, K, Ca, Mg, Al and Fe) and minor (Mn, Ni, Co, Pb, Cr, As, Ba, Li, Be, B, V, Cu, Zn, Se, Rb, Sr, Cd, La, Ce and Bi) elements. For the data analysis, principal component analysis was performed. Among the measured metals, the highest values were determined for the macro and most abundant elements (Na > K > Ca > Fe > Mg > Al). The concentration ranges of the persistently detected elements were as follows: Pb, 0.27-1200 mg kg-1; Cd, 0.01-6.37 mg kg-1; Ni, 0.07-513 mg kg-1; As, 0.01-69.2 mg kg-1; Cu, 5.71-1900 mg kg-1; Zn, 53.6-21,100 mg kg-1; and Cr, 4.93-412 mg kg-1. The critical limit values of metallic elements in soil defined by the legislation of the Republic of Latvia (indicating the level at or above which the functional characteristics of soil are disrupted, or pollution poses a direct threat to human health or the environment) were exceeded in the following numbers of dwellings: Pb = 4, Ni = 2, As = 1, Cu = 16, Cr = 1 and Zn = 28.


Assuntos
COVID-19 , Metais Pesados , Oligoelementos , Humanos , Poeira/análise , Letônia , Cádmio/análise , Chumbo/análise , Controle de Doenças Transmissíveis , Solo/química , Monitoramento Ambiental , Metais Pesados/análise , Oligoelementos/análise
8.
Artigo em Inglês | MEDLINE | ID: mdl-37947525

RESUMO

Exposure to neonicotinoid insecticides is associated with adverse human health outcomes. There is environmental contamination in Saunders County, Nebraska, due to the accumulation of fungicides and insecticides from a now-closed ethanol plant using seed corn as stock. A pilot study quantified environmental contamination in nearby houses from residual pesticides by measuring dust and air (indoor/outdoor) concentrations of neonicotinoids and fungicides at the study site (households within two miles of the plant) and control towns (20-30 miles away). Air (SASS® 2300 Wetted-Wall Air Sampler) and surface dust (GHOST wipes with 4 × 4-inch template) samples were collected from eleven study households and six controls. Targeted analysis quantified 13 neonicotinoids, their transformation products and seven fungicides. Sample extracts were concentrated using solid phase extraction (SPE) cartridges, eluted with methanol and evaporated. Residues were re-dissolved in methanol-water (1:4) prior to analysis, with an Acquity H-Class ultraperformance liquid chromatograph (UPLC) and a Xevo triple quadrupole mass spectrometer. We compared differences across chemicals in air and surface dust samples at the study and control sites by dichotomizing concentrations above or below the detection limit, using Fisher's exact test. A relatively higher detection frequency was observed for clothianidin and thiamethoxam at the study site for the surface dust samples, similarly for thiamethoxam in the air samples. Our results suggest airborne contamination (neonicotinoids and fungicides) from the ethanol facility at houses near the pesticide contamination.


Assuntos
Fungicidas Industriais , Inseticidas , Resíduos de Praguicidas , Praguicidas , Humanos , Resíduos de Praguicidas/análise , Inseticidas/análise , Tiametoxam/análise , Poeira/análise , Fungicidas Industriais/análise , Projetos Piloto , Metanol/análise , Monitoramento Ambiental/métodos , Praguicidas/análise , Neonicotinoides/análise , Sementes/química , Etanol/análise
9.
Ann Work Expo Health ; 66(8): 1010-1021, 2022 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-35716068

RESUMO

In the ever-expanding complexities of the modern-day mining workplace, the continual monitoring of a safe and healthy work environment is a growing challenge. One specific workplace exposure concern is the inhalation of dust containing respirable crystalline silica (RCS) which can lead to silicosis, a potentially fatal lung disease. This is a recognized and regulated health hazard, commonly found in mining. The current methodologies to monitor this type of exposure involve distributed sample collection followed by costly and relatively lengthy follow-up laboratory analysis. To address this concern, we have investigated a data-driven predictive modeling pipeline to predict the amount of silica deposition quickly and accurately on a filter within minutes of sample collection completion. This field-based silica monitoring technique involves the use of small, and easily deployable, Fourier transform infrared (FTIR) spectrometers used for data collection followed by multivariate regression methodologies including Principal Component Analysis (PCA) and Partial Least Squares (PLS). Given the complex nature of respirable dust mixtures, there is an increasing need to account for multiple variables quickly and efficiently during analysis. This analysis consists of several quality control steps including data normalization, PCA and PLS outlier detection, as well as applying correction factors based on the sampler and cassette used for sample collection. While outside the scope of this article to test, these quality control steps will allow for the acceptance of data from many different FTIR instruments and sampling types, thus increasing the overall useability of this method. Additionally, any sample analyzed through the model and validated using a secondary method can be incorporated into the training dataset creating an ever-growing, more robust predictive model. Multivariant predictive modeling has far-reaching implications given its speed, cost, and scalability compared to conventional approaches. This contribution presents the application of PCA and PLS as part of a computational pipeline approach to predict the amount of a deposited mineral of interest using FTIR data. For this specific application, we have developed the model to analyze RCS, although this process can be implemented in the analysis of any IR-active mineral, and this pipeline applied to any FTIR data.


Assuntos
Poluentes Ocupacionais do Ar , Exposição Ocupacional , Poluentes Ocupacionais do Ar/análise , Poeira/análise , Monitoramento Ambiental/métodos , Humanos , Exposição por Inalação/análise , Minerais/análise , Exposição Ocupacional/análise , Dióxido de Silício/análise
10.
Vet Microbiol ; 241: 108545, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31928697

RESUMO

Infectious laryngotracheitis is an important disease of chickens caused by infectious laryngotracheitis virus (ILTV). Outbreaks commonly occur in meat chicken flocks and mass vaccination with live attenuated vaccines, usually in water, is used to control the disease in these populations. Vaccination with live virus via water and nipple drinkers requires stringent adherence to protocols to ensure success, but vaccine administration monitoring is not currently assessed due to a lack of economically viable methods. Vaccinal ILTV has been shown to be detectable in dust in experimental studies and has potential as a method of assessing vaccination success. However, the pattern of vaccinal ILTV detection in dust following vaccination under commercial conditions has not been defined. We report the longitudinal profile of ILTV genome copies (GC) in poultry house dust collected on settle plates following vaccination of 8 flocks of commercial meat chickens on four farms. ILTV GC was enumerated using quantitative real-time polymerase chain reaction (qPCR). There was considerable variation between flocks in the levels of ILTV GC detected post vaccination and this variation was significantly associated with vaccine take measured in individual birds in a companion study. There was no effect of sampling location on ILTV GC in dust but the amount of dust collected was greater in locations closer to the exhaust fans in artificially ventilated houses. Results indicate that measurement of ILTV GC in single or pooled dust samples at 7-8 days post vaccination enables detection of poor vaccine takes and provides a practical means of monitoring ILT vaccination.


Assuntos
Galinhas , Infecções por Herpesviridae/veterinária , Herpesvirus Galináceo 1/imunologia , Vacinação em Massa/veterinária , Doenças das Aves Domésticas/prevenção & controle , Vacinas Virais/administração & dosagem , Animais , DNA Viral/isolamento & purificação , Poeira , Genoma Viral , Infecções por Herpesviridae/prevenção & controle , Herpesvirus Galináceo 1/genética , Abrigo para Animais , Vacinação em Massa/métodos , New South Wales , Doenças das Aves Domésticas/virologia , Reação em Cadeia da Polimerase em Tempo Real/veterinária , Vacinas Virais/genética
11.
Int J Min Sci Technol ; 29(6): 825-830, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31911844

RESUMO

An ignition of methane and air can generate enough air flow to raise mixtures of combustible coal and rock dust. The expanding high temperature combustion products ignite the suspended dust mixture and will continue to propagate following the available combustible fuel supply. If the concentration of the dispersed rock dust is sufficient, the flame will stop propagating. Large-scale explosion tests were conducted within the National Institute for Occupational Safety and Health (NIOSH) Lake Lynn Experimental Mine (LLEM) to measure the dynamic pressure history and the post-explosion dust scour depth. The aim of this effort is to provide quantitative data on depth of dust removal during the early stages of explosion development and its relationship to the depth of floor dust collected for assessing the incombustible content most likely to participate in the combustion process. This experimental work on dust removal on is not only important for coal mine safety but also for industrial dust explosions.

12.
Sci Total Environ ; 610-611: 212-218, 2018 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-28803198

RESUMO

"Green" housing is designed to use low-impact materials, increase energy efficiency and improve occupant health. However, little is known about the indoor mycobiome of green homes. The current study is a subset of a multicenter study that aims to investigate the indoor environment of green homes and the respiratory health of asthmatic children. In the current study, the mycobiome in air, bed dust and floor dust was compared between green (study site) and non-green (control site), low-income homes in Cincinnati, Ohio. The samples were collected at baseline (within four months following renovation), and 12months after the baseline at the study site. Parallel sample collection was conducted in non-green control homes. Air samples were collected by PM2.5 samplers over 5-days. Bed and floor dust samples were vacuumed after the air sampling was completed. The DNA sample extracts were analyzed using ITS amplicon sequencing. Analysis indicated that there was no clear trend in the fungal communities between green and non-green homes. Instead, fungal community differences were greatest between sample types - air, bed, and floor. Microbial communities also changed substantially between sampling intervals in both green and non-green homes for all sample types, potentially indicating that there was very little stability in the mycobiomes. Research gaps remain regarding how indoor mycobiome fluctuates over time. Longer follow-up periods might elucidate the effect of green renovation on microbial load in buildings.


Assuntos
Microbiologia do Ar , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Habitação , Micobioma , Poeira , Humanos , Renda , Ohio , Áreas de Pobreza
13.
Sci Total Environ ; 491-492: 80-6, 2014 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-24462133

RESUMO

An analytical method for the simultaneous determination of 13 organophosphate esters (OPEs) in house dust was developed. The method is based on solvent extraction by sonication, sample cleanup by solid phase extraction (SPE), and analysis by gas chromatography-positive chemical ionization-tandem mass spectrometry (GC/PCI-MS/MS). Method detection limits (MDLs) ranged from 0.03 to 0.43 µg/g and recoveries from 60% to 118%. The inter- and intra-day variations ranged from 3% to 23%. The method was applied to dust samples collected using two vacuum sampling techniques from 134 urban Canadian homes: a sample of fresh or "active" dust (FD) collected by technicians and a composite sample taken from the household vacuum cleaner (HD). Results show that the two sampling methods (i.e., FD vs HD) provided comparable results. Tributoxyethyl phosphate (TBEP), triphenyl phosphate (TPhP), tris(chloropropyl) phosphate (TCPP), tri(2-chloroethyl) phosphate (TCEP), tris(dichloro-isopropyl) phosphate (TDCPP), tricresyl phosphate (TCrP), and tri-n-butyl phosphate (TnBP) were detected in the majority of samples. The most predominant OPE was TBEP, with median concentrations of 31.9 µg/g and 22.8 µg/g in FD and HD samples, respectively, 1 to 2 orders of magnitude higher than other OPEs. The method was also applied to the analysis of OPEs in the National Institute of Standards and Technology (NIST) standard reference material (NIST SRM 2585, organic contaminants in house dust). The results from SRM 2585 may contribute to the certification of OPE concentration values in this SRM.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poeira/análise , Monitoramento Ambiental/métodos , Ésteres/análise , Organofosfatos/análise , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA