1.
BMC Surg ; 23(1): 319, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37872521

RESUMO

Cannulated screw fixation is essential in treating femoral neck fractures, and the widely used freehand technique has several limitations. Therefore, we designed a new laser-positioning and navigation system and compared its efficacy with that of the traditional freehand technique in the cannulated screw fixation of femoral neck fractures. This randomized controlled single-blind trial recruited patients with femoral neck fracture, who were treated using either the newly designed laser-navigation device or the freehand technique. In in-vitro experiments, using the femoral neck model, the laser group was better than the freehand group in terms of operation time (P = 0.0153) and radiation exposure time (P < 0.001). In in-vivo experiments, involving 30 patients (15 in each group), the laser group was better than the freehand group in terms of operation time (P < 0.001), radiation exposure time (P < 0.001), blood loss (P < 0.001) and first success rate (P = 0.03). There was no difference in visual analog scale score, Harris score, and fracture-healing time between the two groups. In conclusion, the novel laser-guiding navigation system resulted in shorter operation time, less radiation exposure, and higher first success rate compared with the freehand technique. Further qualified investigations with a larger number of patients and longer follow-up are required in the future.


Assuntos
Fraturas do Colo Femoral , Colo do Fêmur , Humanos , Colo do Fêmur/cirurgia , Método Simples-Cego , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Fraturas do Colo Femoral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
2.
Arch Orthop Trauma Surg ; 143(4): 1861-1867, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35194658

RESUMO

PURPOSE: This study aimed to estimate the accuracy of pedicle screw (PS) placement in degenerative scoliosis surgery, characterize a patient population with PS misplacement, and analyze the association between misplaced PS vector and lumbar coronal curve. METHODS: In this study, 122 patients (average age 68.6 years), who underwent corrective and decompression surgery, were selected retrospectively. PS accuracy was evaluated in the thoracic to lumbar spine. We identified characteristics of misplacement in each patient. Screw positions were categorized into grade A, entirely in the pedicle; grade B, < 2 mm breach; grade C, 2-4 mm breach; and grade D, > 4 mm breach using postoperative computed tomography. RESULTS: The mean preoperative lumbar coronal curve was 32.3 ± 18.4°, and the number of fused vertebrae was 8.9 ± 2.8. A total of 2032 PS were categorized as follows: grade A, 1897 PS (93.3%); grade B, 67 (3.3%); grade C, 26 (1.3%); and grade D, 43 (2.1%). One PS (grade D), inserted at T5, needed surgery for removal due to neurological deficit. The misplacement group (grades C and D) had a significantly stronger lumbar coronal curve and apical vertebral rotation than the accuracy group (grades A and B). Misplaced PS vector (direction and degree) was significantly correlated with inserted vertebral rotation. Grade D misplacement was distributed mainly around the transitional vertebra of the lumbar curve. CONCLUSIONS: The accuracy of PS insertion in the thoracic to lumbar spine was high in DS surgery, but the need for care was highlighted in the transitional vertebra.


Assuntos
Parafusos Pediculares , Escoliose , Fusão Vertebral , Humanos , Idoso , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Estudos Retrospectivos , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X , Fusão Vertebral/métodos
3.
BMC Surg ; 22(1): 363, 2022 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-36271356

RESUMO

BACKGROUND: Intramedullary nail (IMN) is one of the key essential minimally invasive "weapons" in orthopaedic trauma, while the distal locking is still challenging for surgeons. Although there are various inventions and technologies to improve the locking procedure, there are still problems such as inaccurate positioning, excessive radiation exposure, low first success rate and long learning curve. Therefore, a new laser guiding navigation device was designed and compared with the traditional freehand (FH) technique in the distal locking of femoral IMN. METHODS: This randomized controlled single-blind trial recruited patients with femoral diaphyseal fracture. The self-designed laser navigation device (laser group) and freehand technique (FH group) were used in the distal locking of the IMNs. The patients enrolled were randomized into FH group and laser group, all operations were performed by two surgeons of the same level. The differences between the two groups were compared in terms of radiation exposure time, operative time, first success rate, blood loss, visual analogue score (VAS), Harris score and healing time. RESULTS: 32 patients ended the study period and 16 patients in each group. The results showed that the laser group was better than the FH group in terms of distal locking time (10(9/11) vs 19.5 (17.25/21) min, Z = 4.83, P < 0.001), distal locking radiation exposure time (46.5 (41.25/51.75) vs 105 (88.25/140) s, Z = 4.807, P < 0.001), first success rate (30/32 vs 20/32, χ2 = 9.143, P = 0.002) and blood loss (60 (50-100) vs 150 (105-192.5) mL, Z = 3.610, P = 0.0003). There was no difference in Harris score, VAS score, or fracture healing time between the two groups. CONCLUSION: Compared with the FH technique, the novel laser guiding navigation device for distal locking of femoral IMN has the advantages of shorter operative time, less radiation exposure and higher first success rate. Trial registration Chinese Clinical Trial Registry, ChiCTR2200060236. Registered 23 May 2022, https://www.chictr.org.cn/showprojen.aspx?proj=169130.


Assuntos
Pinos Ortopédicos , Fixação Intramedular de Fraturas , Humanos , Método Simples-Cego , Fluoroscopia/métodos , Fixação Intramedular de Fraturas/métodos , Lasers
4.
Eur Spine J ; 30(5): 1173-1183, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33558972

RESUMO

PURPOSE: This study aimed to compare the pedicle screw placement accuracy and surgical outcomes between 3D-printed (3DP) drill guide template technique and freehand technique in spinal deformity surgery. METHODS: A comprehensive systematic literature search of databases (PubMed, Embase, Cochrane Library, and Web of Science) was conducted. The meta-analysis compared the pedicle screw placement accuracy and other important surgical outcomes between the two techniques. RESULTS: A total of seven studies were included in the meta-analysis, comprising 87 patients with 1384 pedicle screws placed by 3DP drill guide templates and 88 patients with 1392 pedicle screws placed by freehand technique. The meta-analysis results revealed that the 3DP template technique was significantly more accurate than the freehand technique to place pedicle screws and had a higher rate of excellently placed screws (OR 2.22, P < 0.001) and qualifiedly placed screws (OR 3.66, P < 0.001), and a lower rate of poorly placed screws (OR 0.23, P < 0.001). The mean placement time per screw (WMD-1.99, P < 0.05), total screw placement time (WMD-27.86, P < 0.001), and blood loss (WMD-104.58, P < 0.05) were significantly reduced in the 3DP template group compared with the freehand group. Moreover, there was no significant statistical difference between the two techniques in terms of the operation time and correction rate of main bend curve. CONCLUSIONS: This study demonstrated that the 3DP drill guide template was a promising tool for assisting the pedicle screw placement in spinal deformity surgery and deserved further promotion.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Neurocirúrgicos , Impressão Tridimensional
5.
Eur Spine J ; 29(8): 2036-2045, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32447530

RESUMO

PURPOSE: In surgical correction of scoliosis with pedicle screw dual-rod systems, frequently used freehand technique of screw positioning is challenging due to 3D deformity. Screw malposition can be associated with serious complications. Image-guided technologies are already available to improve accuracy of screw positioning and decrease radiation to surgeon. This study was conducted to measure intraoperative radiation to patients in freehand technique, evaluate screw-related complications and compare radiation values to published studies using navigation techniques. METHODS: Retrospective analysis of prospectively collected data of 73 patients with idiopathic scoliosis, who underwent surgical correction with pedicle screw dual-rod system. Evaluated parameters were age, effective radiation dose (ED), fluoroscopy time, number of fused segments, correction and complications. Parameters were compared with regarding single thoracic curve (SC) and double thoracic and lumbar curves (DC), adolescent (10-18 years) or adult (> 18 years) idiopathic scoliosis, length of instrumentation. ED was compared with values for navigation from online database. RESULTS: Average age was 21.0 ± 9.7 years, ED was 0.17 ± 0.1 mSv, time of fluoroscopy was 24.1 ± 18.6 s, 9.5 ± 1.9 fused segments. Average correction for SC was 75.7%, for DC 69.9% (thoracic) and 76.2% (lumbar). No screw-related complications. ED was significantly lower for SC versus DC (p < 0.01), short versus long fusions (p < 0.01), no significant difference for age (p = 0.1). Published navigation data showed 6.5- to 8.8-times higher radiation exposure for patients compared to our results. CONCLUSION: Compared to navigation procedures, freehanded positioning of pedicle screws in experienced hands is a safe and effective method for surgical correction of idiopathic scoliosis with a significant decrease in radiation exposure to patients.


Assuntos
Parafusos Pediculares , Exposição à Radiação , Escoliose , Fusão Vertebral , Adolescente , Adulto , Criança , Humanos , Estudos Retrospectivos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Vértebras Torácicas/diagnóstico por imagem , Vértebras Torácicas/cirurgia , Adulto Jovem
6.
Eur J Orthop Surg Traumatol ; 30(3): 493-499, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31734760

RESUMO

BACKGROUND: ACL reconstruction is one of the commonest orthopaedic procedures performed. There has been a shift in techniques from single bundle to double bundle to anatomic single-bundle reconstruction and also from transtibial to anteromedial method. Anteromedial technique results in more anatomic femoral tunnel with graft positioned at the native insertion site. The tunnel position is crucial for better outcome after ACL reconstruction. PURPOSE: To compare the femoral tunnel position made by anatomic single-bundle ACL reconstruction using femoral offset aimer device versus freehand drilling with 3D computed tomography. STUDY DESIGN: A prospective case series involving 60 patients with ACL tear who underwent anteromedial single-bundle ACL reconstruction. METHODS: Computed tomography scans were performed on 60 knees that underwent single-bundle anteromedial ACL reconstruction with 30 cases involving femoral drilling through aimer device and another 30 cases involving freehand drilling of the tunnel. Three-dimensional models were created, and the data were analysed according to the co-ordinate axes method. Femoral tunnel position was measured in proximal-to-distal and posterior-to-anterior directions. Data from both the groups were compared with each other and already published reference data on anatomical tunnel position. RESULTS: In the aimer group, the femoral tunnel centre on the medial wall of lateral femoral condyle was located at 35 ± 9% in the posterior-to-anterior direction and at 30 ± 12% in the proximal-to-distal direction. In the freehand group, tunnel was placed at 37 ± 10% in posterior-to-anterior and 28 ± 7% in proximal-to-distal directions. There was no significant difference in tunnel position in both the groups. CONCLUSION: This study shows there is no significant difference between both the drilling techniques of femoral tunnel, i.e. freehand drilling and drilling with aimer device. Also, it reiterates the efficacy and utility of computed tomography and three-dimensional reconstruction in the analysis of femoral tunnel in ACL reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Fêmur/diagnóstico por imagem , Humanos , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Pak J Med Sci ; 35(3): 680-684, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31258575

RESUMO

OBJECTIVE: To determine outcome of freehand pedicle screw fixation for dorsal, lumbar and sacral fractures at a tertiary care centre in the developing world. METHODS: A retrospective review was performed of 150 consecutive patients who underwent pedicle screw fixation from January 1, 2012 to 31st December 2017. A total of 751 pedicle screws were placed. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of intra-operative and post-operative radiographs and/or computed tomography. RESULTS: Among the total 751 free hand placed pedicle screws, four screws (0.53%) were repositioned due to a misdirected trajectory towards the disc space. six screws (0.79%) were identified to have cause moderate breach while four screws (0.53%) cause severe breach. There was no occurrence of iatrogenic nerve root damage or violation of the spinal canal. CONCLUSION: Free hand pedicle screw placement based on external landmarks showed remarkable safety and accuracy in our center. The authors conclude that assiduous adherence to technique and preoperative planning is vital to success.

8.
J Craniovertebr Junction Spine ; 15(2): 224-229, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38957756

RESUMO

Introduction: Transpedicular screw placement has superior pullout strength compared to alternative forms of spinal fusion and is often performed in deformity correction surgery with navigation for optimal accuracy and reliability. Freehand technique for pedicle screws minimizes operation time and radiation exposure without fluoroscopy but is not widely adopted given the challenge of difficult anatomical corridors and accurate placement, especially in idiopathic scoliosis and advanced deformity. We used a computer-generated model to assess a proof-of-concept and anatomical feasibility of a freehand screw technique in severe scoliosis. Methods: Three-dimensional (3D) reconstructions of vertebra from a sample of two male patients with severe idiopathic scoliosis deformity (1 thoracic and 1 lumbar) with Cobb angles of 100° were used for planned placement of 17 levels of thoracolumbar (6.5 mm × 45 mm) pedicle screws. 3D reconstruction of each vertebra was created and measurements of screw entries and trajectories were reproduced with a 3D slicer software image computing platform. Results: Accurate transpedicular screw placement is possible with anatomical landmarks based on the 3D reconstructed vertebral levels. A series of 5 figures were assembled to demonstrate sagittal, coronal, and axial planes and key anatomical landmarks and trajectories of thoracic and lumbar freehand pedicle screws in severe idiopathic scoliosis. Conclusions: Anatomical landmarks for freehand transpedicular screw placement (between pedicle, lamina, and superior articulating process) are constant and reliable in severe idiopathic scoliosis as evidenced by 3D computer modeling. Preoperative computed tomography modeling may assist appropriate screw entry and trajectory based on anatomical landmarks for spine surgeons, and guide freehand technique for screw placement in adolescent idiopathic scoliosis.

9.
World Neurosurg ; 181: e163-e176, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37757950

RESUMO

OBJECTIVE: The purpose of this study was to compare the accuracy and safety of robot-assisted (RA) cervical screw placement with conventional freehand (FH) technique. METHODS: Computer-based searches were conducted on various databases including PubMed, Embase, Cochrane Library, Web of Science, the China Biology Medicine, the China National Knowledge Infrastructure, and Wanfang Database. Inclusion criteria were studies reporting the use of RA techniques for cervical screw placement and providing data on safety and accuracy outcomes. Primary outcome indicators focused on the accuracy of screw placement, while secondary outcome indicators included operative time, intraoperative blood loss, length of hospital stay, complication rate, and radiation dose. Data from eligible studies were extracted and synthesized using a forest plot analysis. RESULTS: A total of 312 patients (1233 screws) from 6 studies were included, with 148 patients (47.4% with 567 screws) in the RA group. Perfect screw accuracy, as categorized by Gertzbein-Robbins grade A, was significantly superior with RA surgery compared to FH technique. RA screw implantation significantly reduced complication rates, intraoperative blood loss, length of hospitalization, and radiation dose compared to the conventional FH group. However, there was no statistically significant difference in surgery time between the RA and FH groups. CONCLUSIONS: RA surgery significantly improves the accuracy of cervical screw insertion and offers potential advantages in terms of reduced complications and blood loss, shorter hospital stays, and decreased radiation exposure. However, the impact on operative time remains uncertain. Further high-quality studies, including large-scale randomized controlled trials, are needed to strengthen the evidence base.


Assuntos
Parafusos Pediculares , Exposição à Radiação , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Humanos , Perda Sanguínea Cirúrgica , Procedimentos Cirúrgicos Robóticos/métodos , Fusão Vertebral/métodos , Estudos Retrospectivos
10.
J Pers Med ; 14(2)2024 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-38392576

RESUMO

PURPOSE: We aim to compare radiation exposure and implant-related complications of the freehand (FH) technique versus intraoperative image-guided navigation (IN) for pedicle screw placement in adolescent idiopathic scoliosis (AIS) and estimate associated lifetime attributable cancer risks. METHODS: A retrospective analysis of prospectively collected data from 40 consecutive AIS patients treated with pedicle screw instrumentation using the FH technique was performed. The dose area product (DAP) and effective dose (ED) were calculated. Screw-related complications were analysed, and the age- and gender-specific lifetime attributable cancer risks were estimated. The results were compared to previously published data on IN used during surgery for AIS. RESULTS: There were no implant-related complications in our cohort. Implant density was 86.6%. The mean Cobb angle of the main curve was 75.2° (SD ± 17.7) preoperatively and 27.7° (SD ± 10.8) postoperatively. The mean ED of our cohort and published data for the FH technique was significantly lower compared to published data on the IN technique (p < 0.001). The risk for radiogenic cancer for our FH technique AIS cohort was 0.0014% for male patients and 0.0029% for female patients. Corresponding risks for IN were significantly higher (p < 0.001), ranging from 0.0071 to 0.124% and from 0.0144 to 0.253% for male and female patients, respectively. CONCLUSION: The routine use of intraoperative navigation in AIS surgery does not necessarily reduce implant-related complications but may increase radiation exposure to the patient.

11.
J Clin Med ; 13(17)2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39274285

RESUMO

Background: Femoral neck fractures pose significant surgical challenges with high morbidity and mortality. Traditional freehand screw placement often yields variable outcomes. Recent robotic advancements offer a promising alternative with enhanced precision. Methods: This systematic review compares the efficacy and safety of robot-assisted versus freehand techniques. A comprehensive literature search across multiple databases up to July 2024 included studies comparing both techniques. Primary outcomes were the union rate and time, functional outcomes, operative time, intraoperative parameters, and complication rates. Meta-regression analyses identified treatment response determinants. Results: Twenty-four studies (1437 patients) were included. Robot-assisted screw placement significantly improved the union rate, reduced the union time, and showed superior functional outcomes. Additionally, it resulted in shorter operative times, less intraoperative blood loss, and fewer instances of fluoroscopy and guide pin insertion. The risk of femoral neck necrosis was notably lower with robotic assistance. Meta-regression highlighted the robot type, patient age, and sample size as significant factors. Conclusions: Despite the promise of robot-assisted screw placement, limitations exist. The evidence being mainly from China raises concerns about generalizability. The lack of long-term follow-up data hinders assessment of technique durability. Unreported surgeon expertise levels and learning curves affect result validity. High initial costs and steep learning curves of robotic systems also present barriers to widespread adoption.

12.
Cureus ; 16(7): e64524, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39139314

RESUMO

Fractures of the anterior teeth are a common form of dental trauma. This article includes three case reports of uncomplicated fractures of upper anterior teeth in which collaborators had different treatment protocols. The choice of the treatment method is based on the direction of the specific clinical case and the clinical findings. Of great importance to the treatment approach are the measures taken by the patient to preserve the fractured fragment, the age of the fracture, and the time available to patients and clinicians. When the fractured fragment is available and is well-preserved, the best approach is to fix it to the crown of the tooth. This protocol is extremely fast and inexpensive, with minimal potential for problems in esthetics and function. In the absence of the fractured fragment, the treatment approaches are different, as described in cases 2 and 3. If the patient or the clinician is unable to make a repeat visit, the restoration is carried out using a freehand technique. Protocols involving fracture repair using composite materials are more labor-intensive. Esthetic complications are often observed, which may be due to wrong determined shade, loss of luster, and change over the years in the color of the restoration, as well as fracture of the restoration. With advances in dentistry, these disadvantages have been minimized.

13.
Front Surg ; 10: 1219816, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37609000

RESUMO

Research objective: To propose a technique for placing pedicle screws in the thoracic spine using the Supraspinous ligament Arc Tangent (SLAT) as a guide to increase the safety and stability of screw placement. Content and methods: A retrospective analysis of postoperative anteroposterior and lateral x-ray images was performed for 118 patients with thoracic spine diseases who received conventional freehand technique from January 2016 to May 2020 and SLAT-guided technique since June 2020 to present. The diagnoses included thoracic spinal stenosis, deformity, fractures, infections, and tumors. The angle between the screw and the upper endplate was categorized as grade 1 (0°-5°), grade 2 (5°-10°), and grade 3 (>10°). Three surgeons with more than 10 years of experience in spinal surgery measured the angle between the screw and the upper endplate in the lateral view. Chi-square test was used for statistical analysis, and p < 0.05 was considered statistically significant. Results: A total of 1315 pedicle screws were placed from T1 to T12 in all patients. In the conventional freehand technique group, 549 screws were grade 1, 35 screws were grade 2, and 23 screws were grade 3. In the SLAT-guided freehand technique group, 685 screws were grade 1, 15 screws were grade 2, and 8 screws were grade 3. The data of each group was p < 0.05 by Chi-squared test, which was statistically significant, indicating that the SLAT-guided freehand technique resulted in a higher rate of parallelism between the screws and the upper endplate. All patients underwent intraoperative neurophysiological monitoring, immediate postoperative neurological examination, postoperative x-ray examination, and assess the eventual recovery. The screws were safe and stable, and no complications related to pedicle screw placement were found. Conclusion: The SLAT-guided freehand technique for placing pedicle screws in the thoracic spine can achieve a higher rate of screw-upper endplate parallelism, making screw placement safer and more accurate. Our method provides a convenient and reliable technique for most spinal surgeons, allowing for increased accuracy and safety with less fluoroscopic guidance.

14.
Orthop Surg ; 15(6): 1541-1548, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37183354

RESUMO

OBJECTIVE: It is clinically important for pedicle screws to be placed quickly and accurately. Misplacement of pedicle screws results in various complications. However, the incidence of complications varies greatly due to the different professional titles of physicians and surgical experience. Therefore, physicians must minimize pedicle screw dislocation. This study aims to compare the three nail placement methods in this study, and explore which method is the best for determining the anatomical landmarks and vertical trajectories. METHODS: This study involved 70 patients with moderate idiopathic scoliosis who had undergone deformity correction surgery between 2018 and 2021. Two spine surgeons used three techniques (preoperative computed tomography scan [CTS], visual inspection-X-freehand [XFH], and intraoperative detection [ID] of anatomical landmarks) to locate pedicle screws. The techniques used include visual inspection for 287 screws in 21 patients, preoperative planning for 346 screws in 26 patients, and intraoperative probing for 309 screws in 23 patients. Observers assessed screw conditions based on intraoperative CT scans (Grade A, B, C, D). RESULTS: There were no significant differences between the three groups in terms of age, sex, and degree of deformity. We found that 68.64% of screws in the XFH group, 67.63% in the CTS group, and 77.99% in the ID group were placed within the pedicle margins (grade A). On the other hand, 6.27% of screws in the XFH group, 4.33% in the CTS group, and 6.15% in the ID group were considered misplaced (grades C and D). The results show that the total amount of upper thoracic pedicle screws was fewer, meanwhile their placement accuracy was lower. The three methods used in this study had similar accuracy in intermediate physicians (P > 0.05). Compared with intermediate physicians, the placement accuracy of three techniques in senior physicians was higher. The intraoperative detection group was better than the other two groups in the good rate and accuracy of nail placement (P < 0.05). CONCLUSION: Intraoperative common anatomical landmarks and vertical trajectories were beneficial to patients with moderate idiopathic scoliosis undergoing surgery. It is an optimal method for clinical application.


Assuntos
Parafusos Pediculares , Escoliose , Fusão Vertebral , Humanos , Escoliose/diagnóstico por imagem , Escoliose/cirurgia , Coluna Vertebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Fusão Vertebral/métodos , Estudos Retrospectivos
15.
Neurospine ; 20(1): 240-247, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37016870

RESUMO

OBJECTIVE: The safety and clinical usefulness of minimally invasive scoliosis surgery (MISS) has been reported in various studies. However, freehand pedicle screwing in MISS remains technically challenging. The purpose of this study is to evaluate the accuracy and safety of pedicle screw placement using the freehand technique in adolescent idiopathic scoliosis (AIS) patients treated with MISS compared to conventional open scoliosis surgery (COSS). METHODS: We included 76 patients who underwent deformity correction for AIS. Computed tomography scans were used to assess screw violations divided into 2 groups according to the surgical technique: MISS or COSS. Anterior violations were classified into grade 0, 1 (no contact with internal organs), and 2 (contact with internal organs). Medial and lateral violations were classified into grade 0, 1 ( < 2 mm), and 3 ( ≥ 2 mm). grade 2 were considered critical violations. RESULTS: A total of 630 and 1,174 pedicle screws were inserted in the MISS and COSS groups, respectively. The overall critical violation rates of the MISS and COSS groups were 16.8% (106 screws) and 14.0% (165 screws) (p = 0.116). Medial critical violations on the left side in the middle thoracic region frequently occurred in the MISS group compared to the COSS group (p = 0.003). There were no statistical differences in the complications. CONCLUSION: Pedicle screw placement using the freehand technique in MISS for AIS patients provided similar accuracy and safety compared to COSS. Pedicle screws inserted on the left side of the middle thoracic region, exhibited more medial critical violations in the MISS group.

16.
Indian J Orthop ; 57(8): 1219-1225, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37525732

RESUMO

Purpose: In this study, our aim was to reveal the effect of the medial femoral offset aimer usage through the femoral tunnel entry and exit points and the tunnel length during femoral tunnel drilling in arthroscopic anterior cruciate ligament (ACL) reconstruction. Methods: One hundred patients who underwent arthroscopic single-bundle ACL reconstruction were included in the study. Group 1 consisted of 50 patients who underwent femoral tunnel drilling using a medial portal offset aimer device, while Group 2 consisted of 50 patients who were operated on using the freehand technique. Both groups were compared in terms of femoral tunnel and graft tunnel lengths, femoral tunnel angle in the coronal plane, and the location of the femoral tunnel entry and exit points. Results: The mean femoral tunnel and graft tunnel lengths were significantly longer in Group 2 (p = 0.000). There was no significant difference in terms of localization of the femoral tunnel entry point in both the axial and sagittal planes. The tunnel exit point was located significantly more posterior in Group 1 in the axial plane (p = 0.028). There was no significant difference in terms of the coronal plane femoral tunnel angle between the two groups. Conclusion: In arthroscopic ACL reconstructions, more successful results may be obtained with the freehand technique compared to drilling with a femoral offset aimer. For an experienced orthopedic surgeon, using a medial portal offset aimer device during femoral tunnel drilling does not seem necessary. Supplementary Information: The online version contains supplementary material available at 10.1007/s43465-023-00929-z.

17.
Cureus ; 15(2): e34583, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36883076

RESUMO

Idiopathic intracranial hypertension (IIH) is a syndrome characterized by elevated intracranial pressure, headache, and papilledema. It is frequently associated with obese women and can result in irreversible vision loss. The ventriculoperitoneal (VP) shunt has been proven to be superior to the lumboperitoneal (LP) shunt in IIH patients, with better clinical outcomes. It has been reported that the accurate placement of the ventricular catheter is highly important for shunt survival. However, a slit-like ventricle pattern, typically seen in the disease, has been considered a great concern and challenge for ventricular catheter placement, primarily for freehand technique. Frameless stereotaxy, ultrasound, and endoscopy have been described to improve the accuracy of catheter insertion. However, intraoperative image guidance is not widely accessible, especially in lower-resource countries, due to the high costs associated with its use. Techniques to improve the accuracy of the freehand VP shunt in IIH are scarce in the literature, and any effort to contribute to its development is valuable and helpful.

18.
Clin Neurol Neurosurg ; 217: 107264, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35526512

RESUMO

OBJECTIVE: Several techniques have been described to improve the accuracy of the freehand procedure for frontal ventriculostomy and reduce complications due to suboptimal placement or misplacement of the catheter tip. To date, none of the available studies have found a reliable, low cost and consistent technique. We aimed to provide a standardized protocol for freehand frontal ventriculostomy. METHODS: In the first part of the radiological study, 125 CT scans were used to measure the length of the catheter using 2 right-sided entry points. In the second part, a grid of 24 entry points on the frontal bone was used in 50 CT scans to record the distance from the cranial surface to the Foramen of Monro (FM). Ventriculostomy was performed on six cadaveric heads using a grid of 9 entry points, comparing a 5 ml syringe with the freehand technique to reach the target. RESULTS: The first part of the radiological study showed a length from the cranial surface to the FM was overall 67,38 ± 1,03 mm. For the second part, the mean length of the 24 selected points was 68,54 ± 2,73 mm without statistical difference. In the anatomical study, the FM was reached 8 times (14.8%) with the syringe vs 31 times (57.4%) with the freehand technique, and the ventricles 43 (79.6%) vs 37 (68.5%). The mean lengths from the skull to the FM were 71.33 ± 4.21 mm. CONCLUSIONS: In this study, we showed the optimal length of a frontal ventricular catheter. We have also demonstrated that the portion of the frontal bone above the superior temporal lines matches a sphere in which the center is the FM.


Assuntos
Hidrocefalia , Ventriculostomia , Ventrículos Cerebrais/cirurgia , Cabeça , Humanos , Hidrocefalia/cirurgia , Crânio , Tomografia Computadorizada por Raios X , Ventriculostomia/métodos
19.
J Clin Med ; 11(2)2022 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-35054092

RESUMO

This study describes a new and safe freehand cervical pedicle screw insertion technique using preoperative computed tomography (CT) morphometric measurements as a guide and a medial pedicle pivot point (MPPP) during the procedure. This study included 271 pedicles at 216 cervical spine levels (mean: 4.75 pedicles per patient). A pedicle diameter (PD) ≥ 3.5 mm was the cut-off for pedicle screw fixation. The presence and grade of perforation were detected using postoperative CT scans, where perforations were graded as follows: 0, no perforation; 1, perforation < 0.875 mm; 2, perforation 0.875-1.75 mm; and 3, perforation > 1.75 mm. The surgical technique involved the use of an MPPP, which was the point at which the lines representing the depth of the lateral mass and total length of the pedicle intersected, deep in the lateral mass. The overall success rate was 96.3% (261/271, Grade 0 or 1 perforations). In total, 54 perforations occurred, among which 44 (81.5%) were Grade 1 and 10 (18.5%) were Grade 2. The most common perforation direction was medial (39/54, 72.2%). The freehand technique for cervical pedicle screw fixation using the MPPP may allow for a safe and accurate procedure in patients with a PD ≥3.5 mm.

20.
Orthop Surg ; 14(11): 2995-3002, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36208012

RESUMO

OBJECTIVE: Existing freehand techniques of screw placement mainly emphasized on various entry points and complex trajectory reference. The aim of this study is to illustrate a standardized and reliable freehand technique of pedicle screw insertion for open pedicle screw fixation with a universal entry point and a stereoscopic trajectory reference system and report the results from a single surgeon's clinical experience with the technique. METHOD: In this study, the author respectively reviewed a total of 200 consecutive patients who had undergone open freehand pedicle screw fixation with Superior Articular Process (SAP) technique from January 2019 to May 2020. For accuracy and safety, all 200 cases had undergone postoperative X-ray while 33 cases including spinal deformity, infection, and tumor had received additional CT-scan. Screw accuracy was analyzed via a CT-based classification system with Student's t test. RESULTS: A total of 1126 screws had been placed from T1-S1 with SAP-guided freehand technique and the majority had been confirmed safe in X-ray without the need of CT scan. A total of 316 screws in deformity or infectious or tumor cases had undergone additional CT scan with 95.5% (189 of 198 screws) accuracy in thoracic group and 94.9% (112 of 118 screws) in lumbar group. The accuracy had been 90.5% (114 of 126 screws) in deformity group and 95.8% (182 of 190 screws) in non-deformity group. All perforation cases had been rated Grade B (<2 mm) without significant difference between the medial and the lateral (p < 0.05). No cases had been detected with significant neurological deficiencies. The mean intraoperative X-ray shots were 0.73 per screw. CONCLUSION: SAP-guidance is a reliable freehand technique for thoracic and lumbar pedicle screw instrument. It allows accurate and safe screw insertion in both non-deformity and deformity cases with less radiation exposure.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Humanos , Fusão Vertebral/métodos , Tomografia Computadorizada por Raios X/métodos , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA