Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 415(17): 3313-3325, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37208487

RESUMO

Some aromatic amines (AA) have been classified as carcinogens to humans. After entering the body, mainly through tobacco smoke, they can be detected in urine. Thus, their trace analysis as biomarkers in biofluids is of high relevance and can be achieved with gas chromatography (GC-MS), usually after derivatization. This study compares three gas chromatographic methods for the analysis of ten iodinated derivatives of AA: GC-MS in single-ion monitoring (SIM) mode with (1) electron ionization (GC-EI-MS) and (2) negative chemical ionization (GC-NCI-MS), and (3) GC-EI-MS/MS in multiple reaction monitoring (MRM) mode using electron ionization. All methods and most analytes showed good coefficients of determination (R2 > 0.99) for broad linear ranges covering three to five orders of magnitude in the picogram-per-liter to nanogram-per-liter range, with one and two exceptions for (1) and (2) respectively. Excellent limits of detection (LODs) of 9-50, 3.0-7.3, and 0.9-3.9 pg/L were observed for (1), (2), and (3) respectively, and good precision was achieved (intra-day repeatability < 15% and inter-day repeatability < 20% for most techniques and concentration levels). On average, recoveries between 80 and 104% were observed for all techniques. Urine samples of smokers and non-smokers were successfully analyzed, and p-toluidine and 2-chloroaniline could be found at significantly (α = 0.05) higher concentrations among smokers.


Assuntos
Aminas , Espectrometria de Massas em Tandem , Humanos , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa/métodos , Limite de Detecção
2.
Plant Dis ; 107(7): 2039-2053, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36428260

RESUMO

Brown root rot disease (BRRD), caused by Phellinus noxius, is an important tree disease in tropical and subtropical areas. To improve chemical control of BRRD and deter emergence of fungicide resistance in P. noxius, this study investigated control efficacies and systemic activities of fungicides with different modes of action. Fourteen fungicides with 11 different modes of action were tested for inhibitory effects in vitro on 39 P. noxius isolates from Taiwan, Hong Kong, Malaysia, Australia, and Pacific Islands. Cyproconazole, epoxiconazole, and tebuconazole (Fungicide Resistance Action Committee [FRAC] 3, target-site G1) inhibited colony growth of P. noxius by 99.9 to 100% at 10 ppm and 97.7 to 99.8% at 1 ppm. The other effective fungicide was cyprodinil + fludioxonil (FRAC 9 + 12, target-site D1 + E2), which showed growth inhibition of 96.9% at 10 ppm and 88.6% at 1 ppm. Acropetal translocation of six selected fungicides was evaluated in bishop wood (Bischofia javanica) seedlings by immersion of the root tips in each fungicide at 100 ppm, followed by liquid or gas chromatography tandem mass spectrometry analyses of consecutive segments of root, stem, and leaf tissues at 7 and 21 days posttreatment. Bidirectional translocation of the fungicides was also evaluated by stem injection of fungicide stock solutions. Cyproconazole and tebuconazole were the most readily absorbed by roots and efficiently transported acropetally. Greenhouse experiments suggested that cyproconazole, tebuconazole, and epoxiconazole have a slightly higher potential for controlling BRRD than mepronil, prochloraz, and cyprodinil + fludioxonil. Because all tested fungicides lacked basipetal translocation, soil drenching should be considered instead of trunk injection for their use in BRRD control.


Assuntos
Basidiomycota , Fungicidas Industriais , Fungicidas Industriais/farmacologia , Compostos de Epóxi
3.
Environ Monit Assess ; 191(2): 119, 2019 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-30706205

RESUMO

This study developed a new method to determine the residues of 13 organophosphorus flame retardants (OPFRs) in drinking water by gas chromatography-tandem mass spectrometry (GC-MS/MS) technique and investigated the chemical distribution in water samples from municipal plants along the Yangtze River in Nanjing. The linear calibration correlation coefficients R2 for all 13 OPFRs were at least 0.998 0. Three levels of spiked test were performed. Most of the recoveries were in the range of 80~120%, and the relative standard deviations (RSDs) for the 13 OPFRs were 2.1~17% (n = 6). Five OPFRs were 100% positively detected in the samples, and 3 OPFRs were positively detected in some samples. The concentrations of detected OPFR in the water ranged from 0.7 to 5780.0 ng L-1. The average concentrations of OPFRs in wet season were higher than those in dry season, and the contaminants mainly originated from the source water in the Yangtze River. The exposure assessments of individual and total OPFRs were investigated. The estimated daily intakes of total OPFRs via ingestion of drinking water reached up to 64.8 and 45.2 ng/kg bw/day in dry and wet season, respectively. This study demonstrates a profile of OPFR distribution in Nanjing municipal water and provides information on human exposure assessment via drinking water in the Nanjing District, China.


Assuntos
Água Potável/análise , Monitoramento Ambiental/métodos , Retardadores de Chama/análise , Compostos Organofosforados/análise , Rios/química , Poluentes Químicos da Água/análise , China , Água Potável/normas , Humanos
4.
Wei Sheng Yan Jiu ; 48(1): 120-128, 2019 Jan.
Artigo em Zh | MEDLINE | ID: mdl-31032780

RESUMO

OBJECTIVE: To develop a method for the simultaneous determination of 67 pesticides in water by solid phase extration(SPE) disk extraction-gas chromatography-tandem mass spectrometry(GC-MS/MS). METHODS: Pesticides in water were extracted and cleaned-up with SPE disk, then eluted with dichloromethane-n-ethyl acetate(7∶3, V/V). After the eluent being concentrated to 1 mL under nitrogen blow at 40 ℃, the supernatant was injected into GC-MS/MS for analysis. The GC separation was performed on a DB-5 MS capillary column(30 m×0. 25 mm×0. 25 µm). The pesticides were detected by MS/MS in multiple reaction monitoring(MRM) mode and quantified by working curve method. RESULTS: The linear range of the method for most of the pesticides were in the range of 0. 05-5 µg/L with correlation coefficients of 0. 9924-0. 9999. The quantitative limits(S/N=10) of the method were in the range of 1. 0×10~(-5)-0. 059 µg/L. The recoveries for pesticides were 81. 0%-125. 0% with relative standard deviations of 1. 5%-21. 4%(n=6). CONCLUSION: The method is sensitive, simple, environmentally friendly and suitable to the determination of pesticides in drinking water for rapid screening and quantitative analysis.


Assuntos
Água Potável , Resíduos de Praguicidas , Praguicidas , Água Potável/química , Cromatografia Gasosa-Espectrometria de Massas , Praguicidas/análise , Extração em Fase Sólida , Espectrometria de Massas em Tandem
5.
Se Pu ; 42(3): 282-290, 2024 Mar 08.
Artigo em Zh | MEDLINE | ID: mdl-38503705

RESUMO

Saussurea costus, a perennial herb belonging to the Asteraceae family, is a vital ingredient in traditional Chinese medicine. Increased demands for the herb have led to its widespread cultivation in China, but the corresponding increase in pesticide use has raised concerns about pesticide residues. Such residues would affect the safety and global market potential of Saussurea costus. Thus, a simple method is crucial to detect pesticide residues. The QuEChERS technique, in combination with gas chromatography-tandem mass spectrometry (GC-MS/MS), is commonly used for residue detection. However, traditional adsorbents may be unable to purify complex herbal mixtures well, affecting accuracy and instrument performance. Choosing suitable purification materials for Saussurea costus samples with complex matrices is of significant importance. This study focused on the detection of 35 prohibited pesticides in Saussurea costus. A rapid detection method was established by combining the QuEChERS technique with GC-MS/MS and utilizing a combination of multiwalled carbon nanotubes (MWCNTs), octadecylsilane-bonded silica gel (C18), and anhydrous magnesium sulfate (MgSO4) as the purification adsorbent. The samples were extracted with acetonitrile, purified by an improved QuEChERS process, subjected to GC-MS/MS analysis in multiple reaction monitoring (MRM) mode, and quantified using the internal standard method. The purification effects of four materials (C18, MWCNTs, N-propyl ethylenediamine (PSA), and graphitized carbon black (GCB)) and their optimal dosages were investigated by considering the matrix characteristics of the samples. An orthogonal experimental design was employed to optimize the ratio of adsorbent combinations, and the optimal adsorbent combination was determined to be 450 mg of MgSO4, 400 mg of C18, and 50 mg of MWCNTs. Matrix effect (ME) evaluation of the S. costus matrix showed that 31 target compounds strongly exhibited matrix-enhancement effects. Thus, matrix-matched calibration was employed in this study. Methodological investigation revealed that the standard curves for the 35 pesticides exhibited good linearity, with correlation coefficients (r2) greater than 0.9970. The average recoveries at three spiked levels ranged from 69.6% to 126.9%, and the relative standard deviations (RSDs) for parallel groups were all less than 10%. The limits of detection (LODs) and quantification (LOQs) ranged from 0.2 to 5.4 µg/kg and from 0.6 to 18.1 µg/kg, respectively. The developed method was used to screen and detect 35 pesticide residues in 20 batches of S. costus samples, and the target compounds were detected in six batches. The proposed method is simple, sensitive, and accurate. Thus, it is suitable for the rapid screening and detection of the 35 pesticide residues in S. costus and provides technical support for the cultivation, production, and quality control of the herb.


Assuntos
Nanotubos de Carbono , Resíduos de Praguicidas , Saussurea , Espectrometria de Massas em Tandem/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Nanotubos de Carbono/análise , Nanotubos de Carbono/química , Resíduos de Praguicidas/análise
6.
J Pharm Biomed Anal ; 252: 116503, 2024 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-39383541

RESUMO

Based on precolumn derivatization, an analytical method has been developed for the determination of six high boiling point polyhydric alcohols (HBPAs, b.p. > 300 ℃) in cosmetics and toothpaste, including erythritol, xylitol, Pro-Xylane-S, inositol, mannitol, and sorbitol. The water dispersion and oil in water samples were extracted by distilled water. The water in oil sample was firstly pre-dispersed with acetone, and then extracted by distilled water. The extract was concentrated to dry under nitrogen, and derivatized with acetic anhydride under the dispersion and catalysis of anhydrous pyridine. The derivatives were detected by gas chromatography-tandem mass spectrometry in the selected reaction monitoring mode, and quantified using arabinitol as internal standard. The experimental conditions such as the selection of columns, extraction procedures, and derivative conditions were optimized. This method was properly validated under the optimized conditions, and obtained excellent analytical features. Specifically, the correlation coefficients in the range of 0.02 ∼ 0.5 mg/L all exceed 0.992. The method limits of detection and quantification were 0.25 and 0.8 mg/kg, respectively. The average recoveries in toothpaste, cosmetics with oil in water and water in oil were 81.8 ∼ 107.1 %, with the relative standard deviation were 3.1 ∼ 7.2 %. The established method was successfully applied to commercial samples of different matrices, showing the advantages of simplicity, sensitivity, and good reproducibility, and can be used for the determination of HBPAs in cosmetics and toothpaste. The proposed methodology solves the problem that there is no detection method for HBPAs in cosmetics.

7.
Talanta ; 269: 125445, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38039676

RESUMO

Cloud point extraction is an environmentally benign and simple separation/concentration procedure that can be regarded as an alternative to classical liquid-liquid extraction. In the current work, it was studied the compatibility of cloud point extraction followed by back-extraction in low volume of organic solvent with gas chromatography-mass spectrometry (GC-MS and GC-MS/MS). Triton X-100 was preferred than Triton X-114 as a surfactant to produce the clouding phenomenon and hexane or isooctane was found to be appropriate organic solvents which can be used at the back-extraction step. It was observed that ca. 0.09 % w/w Triton X-100 was co-extracted in the organic phase (hexane or isooctane) so further study was carried out to find out its effect on the GC-MS (GC-MS/MS) measurement when liquid samples are injected without any pre-cleaning to remove the surfactant. The chromatographic separation and the mass detection were not deteriorated by the concomitant Triton X-100 for analysis of several Organochlorine and Organophosphorus pesticides (alpha-HCH, beta-HCH, gamma-HCH, Pentachlorobenzene, Hexachlorobenzene, Chlorpyrifos, Chlorpyrifos-methyl, Aldrin, Endrin, Dieldrin, alpha-Endosulfan, Heptachlor, Heptachlor-endo-epoxide-A, o,p-DDD, p,p-DDD, o,p-DDE, p,p-DDE, o,p-DDT and p,p-DDT). The stability of the GC system when introducing surfactant was assessed as acceptable (typically the peak area RSD% for 20 consecutive injections were below 5 %). Under the developed vaporization conditions using PTV or PSS injectors it can be deduced that Triton X-100 is deposited on the inner surface of the liner. This effect is beneficial since the resulting surfactant layer makes a surface which facilitates the pesticides transfer to the GC column. As a consequence, for some analytes, a substantial enhancement (up to 2.3 times) in the sensitivity was observed when the matrix-matched medium (0.09 % w/w Triton X-100 in organic solvent) is used compared to calibration in solely hexane or isooctane. Meanwhile, the measurement precision in the presence of Triton X-100 remains unchanged. The GC-MS/MS analysis was alternatively accomplished by the use of glass or metal liner and it was found that the glass one should be preferable. Finally, it can be concluded that cloud point extraction with Triton X-100 can be combined with GC-MS or GC-MS/MS analysis by applying liquid injection of the target analytes transferred in organic solvents such as hexane or isooctane. We have established a positive effect of Triton X-100 on the instrumental performance which is on opposite to the generally accepted concern of the negative influence of the surfactants on the gas chromatographic analysis.

8.
Se Pu ; 42(5): 465-473, 2024 Apr 08.
Artigo em Zh | MEDLINE | ID: mdl-38736390

RESUMO

A method based on gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) coupled with one-step QuEChERS technique was developed for the simultaneous determination of 15 N-nitrosamines in air-dried yak meat. The hydration volume, extraction solvent, extracting salt, and cleaning material were optimized according to the characteristics of the N-nitrosamines and sample matrix. The optimized conditions were as follows: 10 mL of purified water for sample hydration, acetonitrile as the extraction solvent for the sample after hydration, 4.0 g of anhydrous MgSO4 and 1.0 g of NaCl as extracting salts, 500 mg of MgSO4+25 mg of C18+50 mg of PSA as cleaning materials. Favorable recoveries of the 15 N-nitrosamines were obtained when the extraction solution was incompletely dried. Thus, the final extract was dried to below 0.5 mL under a mild nitrogen stream and then redissolved to 0.5 mL with acetonitrile. After filtration, 200 µL of the sample was transferred to an autosampler vial for GC-MS/MS analysis. The 15 N-nitrosamines were determined using GC-MS/MS on a DB-HeavyWAX column (30 m×0.25 mm×0.25 µm) with an electron impact ion source in multiple-reaction monitoring (MRM) mode, and quantified using an external standard method. Under the optimized experimental conditions, the results showed that the calibration curves exhibited good linearities for the 15 N-nitrosamines, with correlation coefficients (r2) greater than 0.9990. The limits of detection (LODs) and the limits of quantification (LOQs) ranged from 0.05 to 0.20 µg/kg and from 0.10 to 0.50 µg/kg, respectively. At spiked levels of 1LOQ, 2LOQ, and 10LOQ, the average recoveries were 79.4%-102.1%, 80.6%-109.5%, and 83.0%-110.6%, respectively, and the relative standard deviations were in the range of 0.8%-16.0%. The low matrix effects of the 15 N-nitrosamines indicated the high sensitivity of the proposed method. The method was applied to detect representative commercial air-dried yak meat samples obtained using different processing techniques. Seven N-nitrosamines, including N-nitrosodimethylamine, N-nitrosodiisobutylamine, N-nitrosodibutylamine, N-methyl-N-phenylnitrous amide, N-ethyl-N-nitrosoaniline, N-nitrosopyrrolidine, and N-nitrosodiphenylamine were detected in all samples. The average contents of the seven N-nitrosamines was 0.08-20.18 µg/kg. The detection rates and average contents of the N-nitrosamines in cooked air-dried yak meat samples were higher than those in traditional raw air-dried yak meat samples. Compared with the manual QuEChERS method, the one-step QuEChERS method developed integrated the extraction and clean-up procedures into one single run, and the detection efficiency was considerably improved. The developed method is simple, rapid, highly sensitive, and insusceptible to human errors. Thus, it is useful for the determination of N-nitrosamines in air-dried yak meat and can be extended to the qualitative and quantitative analysis of N-nitrosamines in other meat products. It also provides method support and a data reference for the general determination of N-nitrosamines, which is of great significance for food safety.


Assuntos
Contaminação de Alimentos , Cromatografia Gasosa-Espectrometria de Massas , Carne , Nitrosaminas , Animais , Nitrosaminas/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Bovinos , Contaminação de Alimentos/análise , Carne/análise
9.
Se Pu ; 42(2): 217-223, 2024 Feb.
Artigo em Zh | MEDLINE | ID: mdl-38374603

RESUMO

Rapid industrial and agricultural developments in China have led to the wide use and discharge of chemical products and pesticides, resulting in extensive residues in environmental media. These residues can enter the human body through various pathways, leading to high exposure risks and health hazards. Because the human body is exposed to a variety of chemical pollutants, accurately quantifying the exposure levels of these pollutants in the human body and evaluating their health risks are of great importance. In this study, the serum concentrations of 97 typical chemical pollutants of 60 adults in central China were simultaneously determined using solid-phase extraction coupled with gas chromatography-tandem mass spectrometry (SPE-GC-MS/MS). In this method, 200 µL of a serum sample was mixed with 10 µL of an isotope-labeled internal standard solution. The sample was vortexed and refrigerated overnight at 4 ℃. Each sample was then deproteinized by the addition of 200 µL of 15% formic acid aqueous solution and vortexed. The serum sample was loaded into a preconditioned Oasis® PRiME HLB SPE cartridge and rinsed with 3 mL of methanol-water (6∶1, v/v). The SPE cartridge was subsequently vacuumed. The analytes were eluted with 3 mL of dichloromethane followed by 3 mL of n-hexane. The eluent was concentrated to near dryness under a gentle nitrogen stream and reconstituted with 100 µL of acetone. The samples were determined by GC-MS/MS and separated on a DB-5MS capillary column (30 m×0.25 mm×0.25 µm) with temperature programming. The column temperature was maintained at 70 ℃ for 2 min, increased at a rate of 25 ℃/min to 150 ℃, increased at a rate of 3 ℃/min to 200 ℃, and then held for 2 min. Finally, the column temperature was increased at a rate of 8 ℃/min to 300 ℃ and maintained at this temperature for 8 min. The samples were detected in multiple-reaction monitoring (MRM) mode and quantitatively analyzed using the internal standard method. Multiple linear regression models were used to analyze the effects of demographic characteristics, lifestyle habits, and diet on the concentrations of the chemical pollutants in the serum samples, and known biomonitoring equivalents (BEs) and human biomonitoring (HBM) values were combined to compute hazard quotients (HQs) and hazard indices (HIs) and evaluate the health risks of single and cumulative exposures to the chemical pollutants. The results showed that the main pollutants detected in human serum were organochlorine pesticides (OCPs), polychlorinated biphenyls (PCBs), and polycyclic aromatic hydrocarbons (PAHs). The detection rates of eight pollutants, including hexachlorobenzene (HCB) (100%), pentachlorophenol (PCP) (100%), p,p'-dichlorodiphenylene (p,p'-DDE) (100%), PCB-138 (100%), PCB-153 (98.3%), ß-hexachlorocyclohexane (ß-HCH) (91.7%), fluorene (Flu) (85.0%), and anthracene (Ant) (75.0%), were greater than 70%. The serum levels of ß-HCH were higher in females than in males, and age was positively correlated with exposure to p,p'-DDE, PCB-138, PCB-153, and ß-HCH. Increased exposure levels to p,p'-DDE and ß-HCH may be associated with a high frequency of meat intake, whereas increased exposure level to PCP may be associated with a high frequency of vegetable intake. The serum HQ of PCP was greater than 1 in 6.7% of the samples, and no risk was observed for HCB and p,p'-DDE exposure in the study population. Approximately 28.3% of the study subjects had HI values greater than 1. Overall, the general adult population in this region is widely exposed to a wide range of chemical pollutants, and gender, age, and diet are likely to be the main factors influencing the concentration of chemical pollutants. The health risk of single and compound exposures to chemical pollutants should not be ignored.


Assuntos
Poluentes Ambientais , Hexaclorocicloexano , Hidrocarbonetos Clorados , Pentaclorofenol , Praguicidas , Bifenilos Policlorados , Adulto , Masculino , Feminino , Humanos , Poluentes Ambientais/análise , Diclorodifenil Dicloroetileno/análise , Diclorodifenil Dicloroetileno/metabolismo , Hexaclorobenzeno/análise , Espectrometria de Massas em Tandem , Monitoramento Ambiental , Cromatografia Gasosa-Espectrometria de Massas , Bifenilos Policlorados/análise , Hidrocarbonetos Clorados/análise , Praguicidas/análise , Pentaclorofenol/análise , Medição de Risco
10.
Talanta ; 282: 126967, 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39342671

RESUMO

The current research aims to develop a new analytical method applying a dispersive liquid-liquid microextraction (DLLME) assisted by vortex and using an environmentally friendly extractant for the preconcentration of organochlorine and organophosphorus pesticides followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. The extractant (i.e., natural deep eutectic solvent (NADES)) is safe, cheap, biodegradable and can be prepared by simply mixing DL-menthol and decanoic acid (molar ratio 2:1). The main experimental factors affecting the extraction of all analytes evaluated (19 organochlorine and organophosphorus pesticides) have been optimised using a multivariate analysis consisting in two steps: a Plackett-Burman design followed by a central composite design (CCD). Seven experimental factors have been evaluated: (i) sample volume; (ii) NADES volume; (iii) sample pH; (iv) extraction time; (v) centrifugation time; (vi) centrifugation speed; and (vii) ionic strength (NaCl %, w v-1). For the significant variables, the optimum values were 10 mL sample and 45 µL NADES. No pH adjustment as well as addition of NaCl were needed. The other variables were set at 3 min extraction time, 5 min centrifugation time and 900×g centrifugation speed, respectively. Under the optimised extraction conditions, the limit of quantification (LOQ) values ranged between 0.2 and 78 ng L-1 for all analysed pesticides. Furthermore, the proposed analytical method has been successfully applied to drinking water (bottled spring water). The recovery study (n = 3) has been evaluated at 0.1, 1.0 and 5.0 µg L-1 spiking levels, obtaining relative recovery values within the range of 70 % and 117 % and RSD values between 1 % and 20 % for all the analytes studied, except for p,p-DDT (56-77 % in high conductivity water samples).

11.
Se Pu ; 42(1): 64-74, 2024 Jan 08.
Artigo em Zh | MEDLINE | ID: mdl-38197207

RESUMO

Organophosphorus flame retardants (OPFRs) are widely used in commercial products owing to their exceptional flame-retarding and plasticizing properties. However, OPFRs are also well recognized as emerging persistent organic pollutants (POPs) because of their environmental persistence, biological concentration, and potential toxicity. Thus, the accurate detection of OPFRs in environmental media is critical for analyzing their fate, transport, and ecological risk. However, very few OPFR detection methods are currently available, and the types of OPFRs detected may vary from site to site. In this study, matrix solid-phase dispersion extraction (MSPD), a simple, rapid, and versatile technique for preparing solid, semisolid, liquid, and viscous samples, was combined for the first time with gas chromatography-tandem mass spectrometry (GC-MS/MS) to analyze 10 OPFRs in soil, namely, tripropyl phosphate (TPrP), tri-n-butyl phosphate (TnBP), tri-iso-butyl phosphate (TiBP), tris(2-chloroisopropyl) phosphate (TCIPP), tris(2-chloroethyl) phosphate (TCEP), tris(1,3-dichloro-2-propyl) phosphate (TDCPP), triphenyl phosphate (TPHP), 2-ethylhexyl diphenyl phosphate (EHDPP), triphenylphosphine oxide (TPPO), and trimethylphenyl phosphate (TCP). The GC-MS/MS system was equipped with a Bruker-5MS capillary column coupled with a triple quadrupole mass spectrometer operated in multiple reaction monitoring (MRM) mode. Prior to detection, a mixed standard solution was fortified with 10 ng of13C-PCB208 as an internal standard. The optimal conditions under which MSPD could achieve high selectivity for OPFRs were determined. In addition, single-factor analysis was used to examine the influence of the sorbent (i. e., C18, PSA, Florisil, GCB, and multiwalled carbon nanotubes (MWCNTs)) as well as the dosage, type, and volume of the eluent on the extraction efficiency of the method for the 10 OPFRs. When GCB and ethyl acetate were used as the adsorbent and solvent, respectively, during elution, high extraction recoveries for the OPFRs were achieved. Optimization via response surface methodology (RSM) was adopted to further analyze the impact of three key factors, namely, the adsorbent dosage, eluent volume, and grinding time, as well as their interactions, on OPFR recoveries. Under the optimal conditions of 0.3 g of GCB as the adsorbent, 10 mL of ethyl acetate as the eluent, and 5 min of grinding time, the relative average recovery of the OPFRs was 87.5%. Furthermore, the 10 OPFRs showed good linear relationships under five concentration gradients, with correlation coefficients greater than 0.998. The limits of detection (LODs) and quantification (LOQs) were calculated as signal-to-noise ratios (S/N) of 3 and 10, respectively, and found to be in the ranges of 0.006-0.161 and 0.020-0.531 ng/g, respectively. The performance of the proposed method was verified by determining the recoveries and relative standard deviations (RSDs) of the OPFRs in soils spiked at low, medium, and high levels (10, 20, and 100 ng/g, respectively). The recoveries of the OPFRs ranged from 70.4% to 115.4%, with RSDs ranging from 0.7% to 6.7%. Compared with the conventional accelerated solvent extraction (ASE) method, MSPD presents higher efficiency, simpler operation, and less solvent requirements. The developed method was applied to determine OPFRs in soil samples collected from different sites in Suzhou, including an electronics factory, an auto-repair factory, a paddy field, and a school field. The results revealed that the contents of OPFRs in the soils from the electronics and auto-repair factories were significantly higher than those in the soils from the paddy and school fields. The main pollutants in the soil samples collected from the electronics and auto-repair factories were TCIPP, TPPO, TCEP, and TDCPP. Moreover, the contents of these compounds were 5.30, 4.44, 4.54, and 4.20 ng/g, in soils from the electronics factory and 2.70, 3.93, 7.60, and 5.04 ng/g, in soils from the auto-repair factory. To the best of our knowledge, this study is the first to determine high concentrations of TPPO in industrial soils. Thus, the combination of MSPD and GC-MS/MS adopted in this study can provide useful insights into the detection of the 10 OPFRs in soil.

12.
Se Pu ; 42(1): 75-83, 2024 Jan 08.
Artigo em Zh | MEDLINE | ID: mdl-38197208

RESUMO

Most preservatives are irritating and can easily induce skin sensitivities. Therefore, both domestic and international regulations impose clear restrictions on the use of preservatives in cosmetics. Herein, gas chromatography-tandem mass spectrometry (GC-MS/MS) was employed to simultaneously analyze the levels of 15 preservative allergens in cosmetics. Further, a precise identification approach based on a two-column retention index and mass spectrometry matching degree was developed. Cosmetic samples were extracted via acetonitrile vortex ultrasound extraction and then dehydrated with anhydrous MgSO4. The preservative allergens were separated on two columns, namely, DB-5MS and DB-WAX. Targets were identified using electron impact ionization (EI) source and the multiple reaction monitoring (MRM) mode and characterized using a retention index calibrated by a series of n-alkane standards. Following two tests, the LODs for the 15 preservative allergens on the DB-5MS column were in the range of 0.02-0.2 mg/kg, while those for 12 preservative allergens on the DB-WAX column were in the range of 0.01-20 mg/kg. The preservative allergens on the DB-5MS and DB-WAX columns demonstrated strong correlations, with all correlation coefficients exceeding 0.99. The recoveries for the 15 preservative allergens were in the range of 70.1%-129.8% at low, medium, and high levels, and the relative standard deviations (RSDs) were all below 15% (n=6) when using water, lotion, facial mask, and cream as the representative matrix. Next, 80 batches of genuine samples were tested using the established method. Isopropyl 4-hydroxybenzoate, a prohibited preservative, was detected in two sample batches using the DB-5MS and DB-WAX columns. Additionally, 11 and 10 restricted preservative allergens were identified on the DB-5MS and DB-WAX columns, respectively. The test results indicate that the double-column system approach offers excellent accuracy, effectively preventing false-positive and false-negative results, and can detect the 15 preservative allergens in cosmetics. The use of the retention index for the qualitative detection of these preservative allergens offers valuable options for non-targeted screening and meeting regulatory criteria.


Assuntos
Alérgenos , Cosméticos , Espectrometria de Massas em Tandem , Cromatografia Gasosa-Espectrometria de Massas , Alcanos , Conservantes Farmacêuticos
13.
Se Pu ; 41(1): 76-86, 2023 Jan.
Artigo em Zh | MEDLINE | ID: mdl-36633079

RESUMO

With the increasing number of cosmetic products, their flavor and fragrance components are receiving greater and greater attention. Establishing an analytical method of determining these components in cosmetics is one of the most effective measures to eliminate consumers' concerns. In this study, a method for the simultaneous determination of 28 fragrance residues in cosmetics by gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed. The samples were extracted using methanol and those containing more oil and grease were purified using a neutral alumina solid-phase extraction column, whereas those with more complex compositions were purified by QuEChERS. The analytes in the samples were measured by GC-MS/MS, characterized using their retention times and characteristic ion pairs, and quantified with an external standard. The respective limits of detection (LODs, S/N=3) and quantification (LOQs, S/N>10) of the compounds were in the ranges 2-20 and 5-50 µg/kg. The linearities of the concentration curves of the 28 substances were good in the ranges 1-100, 2-200, 4-200, and 10-1000 µg/L, and the correlation coefficients of the quantitative ion pairs were >0.999. Twenty-eight fragrances were added to blank samples at spiked levels of 50-500 µg/kg, and the recoveries ranged from 71.3% to 120.4%, with RSDs of 1.5%-14.6%. The method could be applied in the determination of fragrances in cosmetics because it was simple, sensitive, and stable and could effectively exclude the interferences of complex matrices. The method was used to determine the fragrance components in 16 cosmetic products, and some fragrance components were detected in 12 samples. Increased attention should be paid to the safeties of fragrances and flavors used in cosmetics.


Assuntos
Cosméticos , Perfumes , Espectrometria de Massas em Tandem , Odorantes/análise , Cromatografia Gasosa-Espectrometria de Massas , Cosméticos/análise , Perfumes/análise , Extração em Fase Sólida , Cromatografia Líquida de Alta Pressão
14.
Se Pu ; 41(7): 610-621, 2023 Jul.
Artigo em Zh | MEDLINE | ID: mdl-37387282

RESUMO

Improvements in living standards have led to an increase in the consumption of animal-derived foods. Pesticides may be used illegally during animal breeding as well as meat production and processing for pest control and preservation. Pesticides applied to crops may also be enriched in animal tissues through the food chain, thereby increasing the risk of pesticide residue accumulation in muscles and visceral tissues and endangering human health. China has stipulated maximum residue limits for pesticide residues in livestock and poultry meat and their viscera. Many other major developed countries and organizations, including the European Union, Codex Alimentarius Commission, and Japan, have also set maximum residue limits for these residues (0.005-10, 0.004-10, and 0.001-10 mg/kg, respectively). Research on pretreatment technologies for pesticide residue detection in plant-derived foods is widely available, but insufficient attention has been paid to animal-derived foods. Thus, high-throughput detection technologies for pesticide residues in animal-derived foods are limited. The impurities that can interfere with the detection process for plant-derived foods mainly include organic acids, polar pigments, and other small molecular compounds; by contrast, the matrix of animal-derived foods is much more complex. Macromolecular proteins, fats, small molecular amino acids, organic acids, and phospholipids can interfere with the detection of pesticide residues in animal-derived foods. Thus, selecting the appropriate pretreatment and purification technology is of great importance. In this study, the QuEChERS technique was combined with online gel permeation chromatography-gas chromatography-tandem mass spectrometry (GPC-GC-MS/MS) to determine 196 pesticide residues in animal-derived foods. The samples were extracted with acetonitrile, purified using the QuEChERS technique coupled with online GPC, detected by GC-MS/MS, determined in multiple reaction monitoring mode (MRM), and quantified using the external standard method. The effects of the extraction solvent and purification agent type on the extraction efficiency and matrix removal of the method were optimized. The purification effect of online GPC on the sample solution was investigated. The optimal distillate receiving time was obtained by studying the recoveries of the target substances and matrix effects over different distillate receiving periods to achieve the effective introduction of target substances and efficient matrix removal. Further, the advantages of the QuEChERS technique combined with online GPC were evaluated. The matrix effects of 196 pesticides were assessed; ten pesticide residues showed moderate matrix effects, while four pesticide residues showed strong matrix effects. A matrix-matched standard solution was used for quantification. The 196 pesticides showed good linearity in the range of 0.005-0.2 mg/L, with correlation coefficients greater than 0.996. The limits of detection and quantification were 0.002 and 0.005 mg/kg, respectively. The recoveries of 196 pesticides at spiked levels of 0.01, 0.05, and 0.20 mg/kg were 65.3%-126.2%, with relative standard deviations (RSDs) of 0.7%-5.7%. The proposed method is rapid, accurate, and sensitive; thus, it is suitable for the high-throughput screening and detection of multiple pesticide residues in animal-derived foods.


Assuntos
Resíduos de Praguicidas , Praguicidas , Animais , Humanos , Espectrometria de Massas em Tandem , Ensaios de Triagem em Larga Escala , Cromatografia Gasosa-Espectrometria de Massas , Cromatografia em Gel
15.
Artigo em Inglês | MEDLINE | ID: mdl-37410937

RESUMO

A method was developed for simultaneous determination of cyanide and thiocyanate in milk by gas chromatography-tandem quadrupole mass spectrometry (GC-MS/MS). Cyanide and thiocyanate were derivatized with pentafluorobenzyl bromide (PFBBr) as PFB-CN and PFB-SCN, respectively. Cetyltrimethylammonium bromide (CTAB) was employed both as a phase transfer catalyst and a protein precipitant in the sample pretreatment, which facilitates the separation of the organic and aqueous phases, and greatly simplifies the pretreatment procedures to achieve simultaneous and rapid determination of cyanide and thiocyanate. Under the optimized conditions, the limits of detection (LODs) of cyanide and thiocyanate in milk were 0.006 mg/kg and 0.015 mg/kg, and the spiked recoveries ranged from 90.1% to 98.2% and from 91.8% to 98.9% with relative standard deviations (RSDs) less than 18.9% and 15.2%, respectively. The proposed method was validated as a simple, fast and highly sensitive method for the determination of cyanide and thiocyanate in milk.


Assuntos
Cianetos , Espectrometria de Massas em Tandem , Animais , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cianetos/análise , Cetrimônio/análise , Leite/química , Tiocianatos/análise
16.
Se Pu ; 40(6): 576-583, 2022 Jun.
Artigo em Zh | MEDLINE | ID: mdl-35616203

RESUMO

At present, the addition of dimethylcyclosiloxanes (DMCs) in cosmetics is being debated and no substantial progress has been made in their safety risk assessment because of the lack of a suitable analytical method. Therefore, it is of theoretical and practical significance to establish a method suitable for the determination of DMCs in cosmetics with different formulation systems. Accordingly, a method based on gel permeation chromatography (GPC) purification combined with gas chromatography-tandem mass spectrometry (GC-MS/MS) was developed for the determination of seven DMCs in cosmetics. The cosmetic samples were extracted by ethyl acetate-cyclohexane (1∶1, v/v), purified by gel permeation chromatography, separated on a DB-5ms column (30.0 m×0.25 mm×0.25 µm), confirmed and detected by gas chromatography-tandem mass spectrometry in the selected reaction monitoring (SRM) mode, and quantified by the internal standard method with n-hexadecane as the internal standard. Experiments were carried out using n-tetradecane, n-hexadecane, and n-octadecane as the internal standards, and based on the retention time in GPC and GC, n-hexadecane was found to be the suitable choice for further analyses. The extraction efficiency for the target compounds was tested in different solvents such as methanol, n-hexane, acetonitrile, ethyl acetate, and ethyl acetate-cyclohexane (1∶1, v/v). Given the high recovery, ethyl acetate-cyclohexane (1∶1, v/v) was selected as the extraction solvent for analyses. Among the three purification methods (analysis without purification, solid-phase extraction (SPE), and GPC purification), GPC was selected as the best method because of the minimal matrix interference to the target compounds. Under the optimized conditions, the seven DMCs showed good linearities in the range of 0.05-1.0 mg/L. The correlation coefficients (r) were 0.994-0.998, which were greater than the required of the specification (r≥0.990). The limits of detection (LODs, S/N=3) were 0.04-0.08 mg/kg, and the limits of quantification (LOQs, S/N=3) were 0.12-0.24 mg/kg. According to the cosmetic matrix in different formulation systems, standard addition recovery tests at three levels of low, medium, and high were carried out. The average recovery rates of the targets were 85.3%-108.8%. The relative standard deviations (RSDs, n=6) were 3.1%-9.4%. The established method was also employed for the analysis of cosmetics in the market, and octamethylcyclotetrasiloxane (D4) and decamethylcyclopentasiloxane (D5) were detected at various levels in the cosmetics. The method established in this study has the advantages of operational simplicity, high sensitivity, and good reproducibility, and it allows for the determination of seven DMCs in cosmetics with different formulation systems. The establishment of this method provides a basis for the quality supervision and inspection of DMCs in cosmetics in China, in addition to providing technical support for follow-up health and safety evaluation.


Assuntos
Cosméticos , Espectrometria de Massas em Tandem , Cromatografia em Gel , Cromatografia Líquida de Alta Pressão , Cosméticos/análise , Cicloexanos/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Extração em Fase Sólida , Solventes/análise
17.
Se Pu ; 40(6): 565-575, 2022 Jun.
Artigo em Zh | MEDLINE | ID: mdl-35616202

RESUMO

A rapid screening method for 84 pesticide residues in dendrobium perfringens parent material with different polarities was developed using a Sin-QuEChERS Nano clean-up column combined with gas chromatography-tandem mass spectrometry (GC-MS/MS). The differences in extraction efficiency of the targets were compared with different extraction solvents (acetonitrile containing 1% acetic acid, acetone) and methods (immersion with or without water). The purification effect and extraction recoveries of Sin-QuEChERS Nano method and classical dispersive solid-phase extraction (dSPE), solid-phase extraction (SPE) and QuEChERS were systematically compared using Dendrobium nobile samples. The differences in matrix effects between the Sin-QuEChERS Nano method, which was more effective in purification, and the dSPE method were also analyzed. The purification effects of three commercially available Sin-QuEChERS Nano purification columns (simple matrix purification column, complex matrix purification column and herbal purification column) were compared. The applicability of the purification methods were also verified by using different parts of Dendrobium nobile samples (stems, leaves and flowers). From the results, it could be concluded that weighing 2.00 g and the samples in 5 mL of water for 20 min, followed by extraction with acetonitrile containing 1% acetic acid was more effective. The average extraction recovery of the target components by Sin-QuEChERS Nano purification method was 90.5%, which further identified Sin-QuEChERS Nano-Chinese medicine purification column as the preferred purification column for dendrobium purification. The target components were separated by a DB-1701MS quartz capillary column (30 m×0.25 mm×0.25 µm) with programmed temperature rise, detected by multiple reaction monitoring (MRM) mode, and quantified by matrix-matched solution external standard method. The GC-MS/MS assay was used for the methodological validation of the 84 representative pesticides within Dendrobium officinale and Dendrobium nobile was carried out by GC-MS/MS detection method. The results indicated that the targets showed excellent linear correlation in different scopes with correlation coefficients (r2) >0. 990. The limits of detection (LODs, S/N=3) of the method were 1.5 to 5.8 µg/kg, and the limits of quantification (LOQs, S/N=10) ranged from 5.0 to 15.0 µg/kg. The spiked recoveries of the target pesticides under different spiked levels were 68.7%-116.2%, and the relative standard deviations (RSDs, n=6) were less than 15%. Compared to other typical pretreatment methods, the Sin-QuEChERS Nano method provided better performance in terms of purification. The method not only effectively removed pigments, organic acids, and alkaline interferents, but also saved preparation time. Losses due to solvent transfer were also avoided and no further vortexing or centrifugation was required, making it a simplified and effective extraction and purification procedure. The method was sensitive, rapid, simple and reliable. It effectively improved the detection efficiency during the rapid screening of pesticides in dendrobium and presented a strong practical application value. In addition, the developed method could further expand the types of target pesticides and could be used to detect more pesticide residues in foods and Chinese herbal medicine. The established Sin-QuEChERS Nano method was used for the analysis of authentic samples. The applicability of the method was evaluated by analyzing a total of 80 samples collected from Anlong, Libo, Dushan, and Yanhe County in Guizhou Province. The types of samples included dendrobium maple, Dendrobium nobile (flowers, stems, leaves) and Dendrobium officinale (flowers, stems, leaves, powder, tablets). At least one pesticide residue was detected in 12 samples, with a detection rate of 15%. The five pesticides with higher detection rates and residues were chlorpyrifos (0.08-0.5 mg/kg), chlorothalonil (0.06-3.2 mg/kg), propanil zinc (0.03-0.15 mg/kg), methyl parathion (0.04-0.23 mg/kg) and cyhalothrin (0.10-2.68 mg/kg). Except for the pesticides in maximum residue limits (MRLs), the pesticide residues detected from dendrobium samples were below the limits set by Chinese national standard (GB 2763-2021) and local standard DBS 52/048-2020.


Assuntos
Dendrobium , Resíduos de Praguicidas , Praguicidas , Acetonitrilas/análise , Cromatografia Gasosa-Espectrometria de Massas , Resíduos de Praguicidas/análise , Praguicidas/análise , Extração em Fase Sólida , Solventes/análise , Espectrometria de Massas em Tandem , Água/análise
18.
Se Pu ; 40(5): 461-468, 2022 May 08.
Artigo em Zh | MEDLINE | ID: mdl-35478005

RESUMO

Owing to their persistence, ease of accumulation in organisms, and high toxicity, the use of persistent organic pollutants (POPs) has been limited ever since the Stockholm Convention on Persistent Organic Pollutants was signed in 2001 by the United Nations Environment Programme (UNEP). As typical POPs, organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) can persist in the environment for long periods. They can enter human bodies through many pathways and pose a high exposure risk to humans. OCPs and PCBs can lead to endocrine disruption, neurotoxicity, immunotoxicity, reproductive toxicity, and cancer in human beings. Accurate quantification of pollutant load levels in vivo is crucial for the evaluation of health effects. In this study, a rapid and sensitive method based on solid phase extraction-gas chromatography-tandem mass spectrometry (SPE-GC-MS/MS) was developed for the simultaneous determination of 35 OCPs and PCBs in serum. Accordingly, 100 µL of the serum sample was gently mixed with the isotope-labeled internal standard solution (10 µL) to obtain a final mass concentration of 10 ng/mL for each internal standard. After incubation overnight, the samples were mixed with 100 µL purified water for dilution. After protein precipitation with 100 mg urea, the serum samples were passed through preconditioned Oasis® HLB cartridges, washed with 6 mL purified water, and eluted with 5 mL hexane-dichloromethane (1∶1, v/v). The SPE eluant was collected, evaporated to near dryness under a gentle nitrogen stream, and dissolved in 100 µL n-hexane. The reconstitution in the vial insert was injected into the GC-MS/MS instrument for analysis. The analytes were separated on an Agilent J&W DB-5MS capillary column (30 m×0.25 mm×0.25 µm) with temperature programming. The mass spectrometer was operated in the electron ionization (EI) mode. The optimal mass spectrometry conditions were realized by optimizing the instrument parameters such as ion pairs and collision energies. The analytes were detected in the multiple reaction monitoring (MRM) mode, and the internal standard method was used for quantitative analysis. The OCPs and PCBs had good linearities in the range of 0.05-50.0 ng/mL. The limits of detection (LODs, S/N=3) ranged from 1.2 to 71.4 ng/L. The recoveries of the 35 compounds were 72.6%-142% with relative standard deviations (RSDs) of less than 25% at the three spiked levels. The developed SPE-GC-MS/MS method was successfully applied to the simultaneous analysis of OCPs and PCBs in serum samples obtained from the general population in Wuhan. The results showed that the general population in Wuhan was widely exposed to OCPs and PCBs, especially the former. The detection frequencies of eight OCPs and seven PCBs were greater than 50%, and p,p'-DDE, p,p'-DDD, and methoxychlor were detected in all serum sample pools. Non-dioxin-like PCBs (NDL-PCBs) were the dominant PCB congeners, while PCB-28, PCB-153, and PCB-52 were the dominant PCBs in the general population of Wuhan. The concentration of OCPs increased with age. Moreover, the concentration of OCPs in individuals who were more than 66 years old was significantly higher as compared to that in younger individuals. The positive association differing by gender was significant in individuals over 60 years of age. There were no significant differences in PCB concentrations according to gender or age. There were no seasonal differences in the residue levels of OCPs and PCBs in the general population of Wuhan. The developed method is rapid and sensitive; it has the advantages of low limits of detection, satisfactory recoveries, accurate precision, and microsample volume, thus allowing for the simultaneous analysis of trace OCPs and PCBs in microserum samples in epidemiological studies. This robust analytical method also provides a powerful tool for the health risk assessment of OCP and PCB exposure.


Assuntos
Poluentes Ambientais , Hidrocarbonetos Clorados , Praguicidas , Bifenilos Policlorados , Idoso , Poluentes Ambientais/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Hidrocarbonetos Clorados/análise , Pessoa de Meia-Idade , Poluentes Orgânicos Persistentes , Praguicidas/análise , Bifenilos Policlorados/análise , Reprodutibilidade dos Testes , Extração em Fase Sólida/métodos , Espectrometria de Massas em Tandem , Água
19.
Se Pu ; 40(5): 469-476, 2022 May 08.
Artigo em Zh | MEDLINE | ID: mdl-35478006

RESUMO

A modified QuEChERS method, based on multi-walled carbon nanotubes (MWCNTs), was established for the detection of 10 pyrethroid pesticides (cyfluthrin, flucythrinate, fenpropathrin, bifenthrin, cyhalothrin, permethrin, cypermethrin, etofenprox, fenvalerate, deltamethrin) in tea, in combination with gas chromatography-tandem mass spectrometry (GC-MS/MS). The purification effects and dosages of four carbon nanomaterials, viz. single-walled carbon nanotubes (SWCNTs), MWCNTs, amino-modified MWCNTs, and graphene, were compared. An orthogonal experimental design was used to determine the optimal experimental conditions for sample pretreatment. The experimental factors governing the process were analyzed using variance. The results showed that the optimized sample pretreatment parameters were as follows. Acetonitrile was used as the extraction solvent with ultrasonic extraction for 35 min, while 60 mg MWCNTs, 200 mg PSA, and 200 mg C18, were used as purifiers. The effects of the extraction solvent and the carbon nanomaterials used on the recoveries of the 10 pyrethroid pesticides were significantly different (p<0.001), and the effect of extraction time on the recoveries was statistically different (p<0.05). The dosage of carbon nanomaterials had no significant effect on the recoveries (p>0.05). Good linearities were observed for the 10 pyrethroid pesticides in the concentration range of 0.01-2 mg/L. The limits of detection (LODs) and limits of quantification (LOQs) were in the ranges of 0.001-0.01 mg/kg and 0.005-0.04 mg/kg, respectively. The average recoveries of the pyrethroid pesticides spiked into blank samples of green tea were 91.4%-109.7%, and the relative standard deviations were 0.12%-9.80% (n=6). Furthermore, the matrix effects (MEs) of scented green tea, green tea, and black tea were evaluated. It was found that the addition of MWCNTs to the purifier can effectively reduce the matrix effect in green tea and black tea matrices. The developed method and the national standard method were used to detect the residues of the 10 pyrethroid pesticides in 120 tea samples available in the market. The results showed that cyfluthrin, deltamethrin, fenvalerate, permethrin, fenpropathrin, cypermethrin, bifenthrin and cyhalothrin were detected, and the contents obtained with the two methods were similar. Although pyrethroids were detected in most tea samples, the contents of all pesticide residues were below the maximum residue limits (MRLs). Therefore, the developed method is suitable for the rapid quantitative analysis of pesticide residues in tea.


Assuntos
Nanotubos de Carbono , Resíduos de Praguicidas , Praguicidas , Piretrinas , Cromatografia Gasosa-Espectrometria de Massas/métodos , Nanotubos de Carbono/análise , Nanotubos de Carbono/química , Permetrina/análise , Resíduos de Praguicidas/análise , Praguicidas/análise , Piretrinas/análise , Projetos de Pesquisa , Solventes/análise , Espectrometria de Massas em Tandem , Chá/química
20.
Se Pu ; 40(11): 1022-1030, 2022 Nov.
Artigo em Zh | MEDLINE | ID: mdl-36351811

RESUMO

Polycyclic aromatic hydrocarbons (PAHs) are among the most harmful persistent organic pollutants that possess high carcinogenicity and teratogenicity; hence, establishing a highly sensitive analytical method for monitoring PAHs in environmental samples is an urgent need. However, due to the low PAHs content in environmental samples and the complex matrix of the samples, it is difficult to directly determine the amount of PAHs using the existing analytical instruments. Therefore, an essential pretreatment of environmental samples should be carried out before instrumental analysis. In most pretreatment techniques, the extraction efficiency depends on the characteristics of the extraction materials. Currently, metal-organic framework materials (MOFs), which are porous materials self-assembled by metal ions and organic ligands, are used as solid-phase microextraction (SPME) coating materials for the extraction of PAHs. However, the following problems limit the application of MOFs in the SPME field: (1) MOF coating materials often require a long equilibration time for extraction because the it is difficult for the target to reach the deep adsorption sites; (2) In addition, most MOFs are formed by the coordination of single metal ions with organic monomers. The single type of open metal active sites is not conducive for realizing high extraction performance. In this study, a hollow bimetal-organic framework (H-BiMOF) was synthesized by the solvothermal method and characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), nitrogen adsorption-desorption analysis, thermogravimetric analysis, etc. The TEM images and XRD patterns demonstrated the successful synthesis of H-BiMOF with a hollow structure, which was formed through the competitive coordination between benzoic acid and water. The H-BiMOF material showed type-Ⅳ isotherms with a surface area of 1437 m2/g and excellent thermal stability. Subsequently, a H-BiMOF-coated SPME fiber was prepared by the physical adhesion method and used to extract trace PAHs from environmental samples. Due to the hollow structure of H-BiMOF, the prepared fibers offer the advantages of high utilization of specific surface area as well as short mass transfer distance, so that the extraction process quickly reaches equilibrium. At the same time, the introduction of bimetals provides a variety of metal active sites, which improves the extraction efficiency of the fiber against electron-rich cloud targets such as PAHs. The prepared fiber also had good service life, with at least 150 cycles. Combined with gas chromatography-tandem mass spectrometry (GC-MS/MS), a new method for the determination of PAHs in environmental water samples was established. Single factor experiments were performed to investigate the effects of the SPME conditions on the analytical performance. Under the optimal conditions, the established method showed low limits of detection (0.01-0.08 ng/L), wide linear range (0.03-500.0 ng/L), good linearity (correlation coefficients≥0.9986), and acceptable reproducibility (relative standard deviations≤9.8%, n=5). Finally, typical water samples were analyzed by the established method. Four environmental water samples were collected from Dianchi Lake, Poyang Lake, Taihu Lake, and Xihu Lake in China. No benzo(a)anthracene (BaA) and chrysene (CHR) were detected in any of the water samples. However, 17.9 ng/L of fluorene (FLU) and 5.3 ng/L of phenanthrene (PHE) were found in the Poyang Lake sample; 11.3 ng/L of fluoranthene (FLA) and 24.2 ng/L of pyrene (PYR) were found in the Taihu Lake sample; 50.0 ng/L of FLU, 19.5 ng/L of PHE, 14.9 ng/L of anthracene (ANT), 34.2 ng/L of FLA, and 44.5 ng/L of PYR were found in the Xihu Lake sample. The contents of the PAHs detected in all the lake water samples were lower than the Chinese National Standard GB 5749-2006 (2000.0 ng/L). The results of this study indicate that the developed method is suitable for the sensitive detection of trace levels of PAHs in real environmental water samples.


Assuntos
Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Hidrocarbonetos Policíclicos Aromáticos/análise , Microextração em Fase Sólida/métodos , Espectrometria de Massas em Tandem , Reprodutibilidade dos Testes , Cromatografia Gasosa-Espectrometria de Massas/métodos , Poluentes Químicos da Água/análise , Limite de Detecção , Metais , Água , Antracenos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA