Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38762151

RESUMO

BACKGROUND: All-suture buttons (ASBs) and interference screw (IS) are commonly utilized in the inlay subpectoral biceps tendon tenodesis. However, the biomechanical characteristics of these two methods have not been compared directly. The aim of present study was to compare the biomechanical properties of ASB vs. IS for inlay subpectoral biceps tendon tenodesis in a human cadaveric model. METHODS: Sixteen fresh-frozen human cadaveric shoulders were randomly divided into two experimental inlay biceps tenodesis groups: ASB or IS. After tenodesis, every specimen was preloaded at 5 N for 2 minutes, followed with a cyclic loading test from 5 to 70 N for 500 load cycles. Then the load-to-failure test was performed. Afterward, the humerus was placed in a cylinder tube and secured with anchoring cement. Lastly, a two-point bending test was performed to determine the strength of the humerus. Destructive axial force was applied, and the failure strength and displacement were recorded. RESULTS: No difference in stiffness was observed between the two groups (ASB = 27.4 ± 3.5 N/mm vs. IS = 29.7 ± 3.0 N/mm; P = .270). Cyclic displacement was significantly greater in the ASB group (6.8 ± 2.6 mm) than the IS group (3.8 ± 1.1 mm; P = .021). In terms of failure load, there were no statistical differences among the two groups (P = .234). The ASB group was able to withstand significantly greater displacement (11.9 ± 1.6 mm) before failure than the IS group (7.8 ± 1.5 mm; P = .001). During the humeral bending test, the ASB group exhibited significantly greater maximal load (2354.8 ± 285.1 N vs. 2086.4 ± 296.1 N; P = .046) and larger displacement (17.8 ± 2.8 mm vs. 14.1 ± 2.8 mm; P = .027) before fracture. CONCLUSIONS: In inlay subpectoral bicep tenodesis, ASB fixation appears to offer comparable stiffness and failure load to that of IS fixation. Additionally, the ASB group exhibited greater resistance to load and displacement before humeral fracture. However, the ASB group did demonstrate increased cyclic displacement compared to IS group.

2.
Eur J Orthop Surg Traumatol ; 34(2): 989-993, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37821629

RESUMO

PURPOSE: This single-centre study aimed to review the postoperative outcomes of distal biceps avulsion repair using a single incision with the endo-button technique. METHODS: A retrospective cohort study was performed of a single surgeon series of distal biceps repairs performed consecutively from September 2016 to September 2020. At two years, outcome measures included Oxford Elbow Score (OES), range of movement (ROM), complications and ongoing issues. RESULTS: Forty-five distal biceps tendon repairs were performed on 43 patients with a mean follow-up of 3.2 years (1.1-5.3). The average OES was 46 (11-48), and 90% of patients recovered a comparable range of movement to the contralateral side. Two patients developed re-rupture (4%) on days 0 and 9 of surgery, but there were no late re-ruptures of the repair. CONCLUSION: Short-term outcomes from distal biceps tendon repair show low complication rates, high patient satisfaction and good functional outcomes. The results would support acute surgical treatment of active, working-age, patients with distal biceps tendon ruptures.


Assuntos
Traumatismos dos Tendões , Humanos , Seguimentos , Estudos Retrospectivos , Traumatismos dos Tendões/cirurgia , Músculo Esquelético/cirurgia , Cotovelo , Ruptura/cirurgia , Resultado do Tratamento
3.
Arch Orthop Trauma Surg ; 143(4): 1923-1930, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35287180

RESUMO

INTRODUCTION: There is no evidence on screw diameter with regards to tunnel size in anterior cruciate ligament reconstruction (ACLR) using hybrid fixation devices. The hypothesis was that an undersized tunnel coverage by the tibial screw leads to subsequent tunnel enlargement in ACLR in hybrid fixation technique. METHODS: In a retrospective case series, radiographs and clinical scores of 103 patients who underwent primary hamstring tendon ACLR with a hybrid fixation technique at the tibial site (interference screw and suspensory fixation) were obtained. Tunnel diameters in the frontal and sagittal planes were measured on radiographs 6 weeks and 12 months postoperatively. Tunnel enlargement of more than 10% between the two periods was defined as tunnel widening. Tunnel coverage ratio was calculated as the tunnel diameter covered by the screw in percentage. RESULTS: Overall, tunnel widening 12 months postoperatively was 23.1 ± 17.1% and 24.2 ± 18.2% in the frontal and sagittal plane, respectively. Linear regression analysis revealed the tunnel coverage ratio to be a negative predicting risk factor for tunnel widening (p = 0.001). The ROC curve analysis provided an ideal cut-off for tunnel enlargement of > 10% at a tunnel coverage ratio of 70% (sensitivity 60%, specificity 81%, AUC 75%, p < 0.001). Patients (n = 53/103) with a tunnel coverage ratio of < 70% showed significantly higher tibial tunnel enlargement of 15% in the frontal and sagittal planes. The binary logistic regression showed a significant OR of 6.9 (p = 0.02) for tunnel widening > 10% in the frontal plane if the tunnel coverage ratio was < 70% (sagittal plane: OR 14.7, p = 0.001). Clinical scores did not correlate to tunnel widening. CONCLUSION: Tibial tunnel widening was affected by the tunnel diameter coverage ratio. To minimize the likelihood of disadvantageous tunnel expansion-which is of importance in case of revision surgery-an interference screw should not undercut the tunnel diameter by more than 1 mm.


Assuntos
Ligamento Cruzado Anterior , Artroplastia , Tíbia , Humanos , Ligamento Cruzado Anterior/cirurgia , Parafusos Ósseos , Radiografia , Estudos Retrospectivos , Tíbia/cirurgia
4.
Arch Orthop Trauma Surg ; 143(2): 935-949, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35290503

RESUMO

BACKGROUND: There is currently no consensus regarding the preferred surgical procedure for the reconstruction of anterior cruciate ligament (ACL). The interference screw technique is widely used, but has been associated with a risk of graft damage. The Press-Fit-Hybrid®-technique is one of the alternatives for biological ACL-reconstruction with minimal implant requirements. The hypothesis of this retrospective analysis is, that the Press-Fit-Hybrid®-technique leads to better results with respect to re-rupture rate and secondary meniscal lesion than the interference-screw-technique. METHODS: To compare the re-rupture rate of the interference-screw-technique (IF) used until 2015 with the currently used Press-Fit-Hybrid®-technique (PFH), the last 100 patients of the IF-group and the first 100 patients of the PFH-group were retrospectively analyzed. Primary outcomes were re-rupture rate, complications and secondary meniscal injury. Additionally, laxity, Lachman and Pivot-shift and range of motion were evaluated. RESULTS: A mean follow-up of 4.2 and 5.3 years revealed 4% and 9% re-rupture rates and 1% and 2% complication rates in the PFH- and IF-group, respectively. In the PFH-group there were no re-ruptures in patients older than 23 years. Secondary meniscal injury post-surgery was 6% and 9% for the PFH and IF-group, respectively. Knee stability was similar in both groups. Range of motion was significantly better in the PFH-group, with 136° of flexion, 6 months after surgery. CONCLUSION: For ACL-reconstruction the Press-Fit-Hybrid®-technique is an alternative new method. Low level of secondary meniscal lesions after surgery and high stability, is known to prevent later arthrosis of the knee. The encouraging observed trend of the reduction of the re-rupture rate in revision surgery and in young patients using the Press-Fit-Hybrid®-technique in comparison to the interference-screw-technique must be confirmed with further studies. LEVEL OF EVIDENCE: Therapeutic Level III, retrospective cohort study.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Estudos Retrospectivos , Seguimentos , Articulação do Joelho/cirurgia , Parafusos Ósseos , Lesões do Ligamento Cruzado Anterior/cirurgia , Ruptura/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Reconstrução do Ligamento Cruzado Anterior/métodos
5.
Medicina (Kaunas) ; 59(2)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36837591

RESUMO

Background and Objectives: Tunnel enlargement (TE) is a widely reported phenomenon after anterior cruciate ligament reconstruction (ACLR). Given the paucity of knowledge in the literature, it remains unclear whether screw position in the tunnel affects TE. This retrospective cohort study evaluated differences in postoperative tunnel enlargement rates (TER) and clinical results between anterior and posterior tibial interference screw insertion during single-bundle ACLR using autologous hamstring grafts. Materials and Methods: A group of consecutive patients that underwent primary arthroscopic single-bundle ACLR in our hospital were screened and divided into two groups based on the position of the tibial interference screw (determined by Computer Tomography within 3 days after surgery): anterior screw position group (A) and posterior screw position group (B). The bone tunnel size was measured using magnetic resonance imaging (MRI) performed 1 year after surgery. International Knee Documentation Committee (IKDC) score and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were used for clinical results 1 year postoperatively. Results: 87 patients were included. The TER of Group A is higher than that of Group B (43.17% vs. 33.80%, p = 0.024). Group A showed a significant increase (12.1%) in enlargement rates at the joint line level than group B (43.77% vs. 31.67%, p = 0.004). Moreover, KOOS and IKDC scores improved in both groups. There were no significant differences in clinical outcomes between the two groups. Conclusions: One year after ACLR, patients with posterior screw showed significantly lower TE than patients with anterior screw. However, the position of screw did not lead to differences in clinical results over our follow-up period. Posterior screw position in the tibial tunnel maybe a better choice in terms of reducing TE. Whether the different screw positions affect the long-term TE and long-term clinical outcomes needs to be confirmed by further studies.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Estudos Retrospectivos , Ligamento Cruzado Anterior , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Parafusos Ósseos , Reconstrução do Ligamento Cruzado Anterior/métodos , Lesões do Ligamento Cruzado Anterior/cirurgia , Fêmur
6.
Int J Mol Sci ; 23(23)2022 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-36498952

RESUMO

This study evaluated the mid-term (12-month) biomechanical, biocompatibility, and biological performance of additive-manufactured bioabsorbable iron-based interference screws (ISs). Two bioabsorbable iron IS types-manufactured using pure iron powder (iron_IS) and using pure iron powder with 0.2 wt% tricalcium phosphate (TCP_IS)-were compared with conventional metallic IS (control) using in vitro biocompatibility and degradation analyses and an in vivo animal study. The in vitro ultimate failure strength was significantly higher for iron_IS and TCP_IS than for control ISs at 3 months post-operatively; however, the difference between groups were nonsignificant thereafter. Moreover, at 3 months after implantation, iron_IS and TCP_IS increased bone volume fraction, bone surface area fraction, and percent intersection surface; the changes thereafter were nonsignificant. Iron_IS and TCP_IS demonstrated degradation over time with increased implant surface, decreased implant volume, and structure thickness; nevertheless, the analyses of visceral organs and biochemistry demonstrated normal results, except for time-dependent iron deposition in the spleen. Therefore, compared with conventional ISs, bioabsorbable iron-based ISs exhibit higher initial mechanical strength. Although iron-based ISs demonstrate high biocompatibility 12 months after implantation, their corrosive iron products may accumulate in the spleen. Because they demonstrate mechanical superiority along with considerable absorption capability after implantation, iron-based ISs may have potential applications in implantable medical-device development in the future.


Assuntos
Fosfatos de Cálcio , Ferro , Animais , Coelhos , Ferro/química , Porosidade , Implantes Absorvíveis
7.
Arch Orthop Trauma Surg ; 142(8): 2111-2120, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35397657

RESUMO

INTRODUCTION: In the reconstruction of distal radioulnar ligaments (DRULs), interference screws can be used for antegrade or retrograde fixation of grafts to the ulna. However, the biomechanics of interference screw fixation are currently unknown. This study aimed to determine the biomechanical effects of these two fixations on the distal radioulnar joint (DRUJ) in a cadaveric model and to investigate the appropriate initial tension. MATERIALS AND METHODS: A total of 30 human cadaver upper extremities were used, and the DRULs were reconstructed according to Adams' procedure. First, eight specimens were randomly divided into two groups: antegrade and retrograde, followed by translational testing and load testing. Then, the other eight specimens were divided into the two groups above, and the contact mechanics, including forces, areas, and pressures, were measured. Finally, to investigate the appropriate initial tension, the remaining 14 specimens were fixed with interference screws under different tensions in an antegrade way, and the translational testing was repeated as before. RESULTS: In the neutral position, antegrade fixation exhibited less translation than retrograde fixation (7.21 ± 0.17 mm versus 10.77 ± 1.68 mm, respectively). The maximum failure load was 70.45 ± 6.20 N in antegrade fixation, while that in retrograde fixation was 35.17 ± 2.95 N (P < 0.0001). Antegrade fixation exhibited a larger increase in contact force than retrograde fixation (99.72% ± 23.88% versus 28.18% ± 10.43%) (P = 0.001). The relationship between tension and displacement was nonlinear (Y = - 1.877 ln(x) + 7.94, R2 = 0.868, P < 0.0001). CONCLUSIONS: Compared with retrograde fixation, the antegrade fixation of interference screws may be a more reliable surgical technique, as it shows a higher failure load and stability. In addition, to avoid the risk of potential arthritis caused by anterograde fixation, we propose an equation to determine the appropriate initial tension in DRUL reconstruction.


Assuntos
Ulna , Articulação do Punho , Fenômenos Biomecânicos , Parafusos Ósseos , Cadáver , Humanos , Ligamentos , Articulação do Punho/cirurgia
8.
Medicina (Kaunas) ; 58(9)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36143870

RESUMO

Background: Although the use of adjustable-loop suspensory fixation has increased in recent years, the influence of the shortcomings of suspensory fixation, such as the bungee-cord or windshield-wiper effects, on tunnel widening remains to be clarified. Hypothesis/Purpose: The purpose of this study was to compare adjustable-loop femoral cortical suspensory fixation and interference screw fixation in terms of tunnel widening and clinical outcomes after anterior cruciate ligament reconstruction (ACLR). We hypothesized that tunnel widening in the adjustable-loop femoral cortical suspensory fixation (AL) group would be comparable to that in the interference screw fixation (IF) group. Methods: This study evaluated patients who underwent primary ACLR at our institution between March 2015 and June 2019. The femoral and tibial tunnel diameters were measured using plain radiographs in the immediate postoperative period and 2 years after ACLR. Tunnel widening and clinical outcomes (Lysholm score, 2000 International Knee Documentation Committee subjective score, and Tegner activity level) were compared between the two groups. Results: There were 48 patients (mean age, 29.8 ± 12.0 years) in the AL group and 44 patients (mean age, 26.0 ± 9.5 years) in the IF group. Tunnel widening was significantly greater in the AL group than that in the IF group at the tibia anteroposterior (AP) middle (2.03 mm vs. 1.32 mm, p = 0.017), tibia AP distal (1.52 mm vs. 0.84 mm, p = 0.012), tibia lateral proximal (1.85 mm vs. 1.00 mm, p = 0.001), tibia lateral middle (2.36 mm vs. 1.03 mm, p < 0.001), and tibia lateral distal (2.34 mm vs. 0.85 mm, p < 0.001) levels. There were no significant differences between the two groups with respect to femoral tunnel widening and clinical outcomes. Conclusions: Tibial tunnel widening was significantly greater in the AL group than in the IF group at 2 years after primary ACLR. However, the clinical outcomes in the two groups were comparable at 2 years.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Adolescente , Adulto , Ligamento Cruzado Anterior/cirurgia , Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Parafusos Ósseos , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Adulto Jovem
9.
Medicina (Kaunas) ; 58(3)2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35334611

RESUMO

Background and Objectives: Anterior cruciate ligament (ACL) tears are common injuries in the athletic population, and accordingly, ACL reconstruction (ACLR) is among the most common orthopedic surgical procedures performed in sports medicine. This study aims to compare the semitendinosus/gracilis (ST/G) and ACL hamstring grafts fixed using adjustable cortical suspension in both the femur and tibia (MAI) ACLR techniques. We aimed to compare the results of single-leg hop tests (SLHT) applied in different directions and limb symmetry indices (LSI) in athletes with a 6-month post-operative ACLR history. Materials and Methods: A retrospective cohort of 39 athletes from various sports branches who underwent MAI (n = 16) and ST/G (n = 23) ACLR techniques by the same surgeon were evaluated. The knee strength of the participants on the operated and non-operated sides was evaluated with five different SLHTs. The SLHT included the single hop for distance (SH), triple hop for distance (TH), crossover triple hop for distance (CH), medial side triple hop for distance (MSTH), and medial rotation (90°) hop for distance (MRH). Results: There was a significant improvement in the mean Lysholm, Tegner, and IKDC scores in the post-operative leg for both techniques (p < 0.05) compared to the pre-operative levels. When there was a difference between the SH of the operative and the non-operative legs in the ST/G technique (p < 0.05), there was no significant difference in the other hop distance for both ST/G and MAI (p > 0.05). There was no difference between the techniques regarding the LSI scores. Conclusions: The fact that our research revealed similar LSI rates of the SLHTs applied in different directions in the ST/G and MAI techniques assumes that the MAI technique can be an ACLR technique which can be functionally used in athletes.


Assuntos
Músculos Isquiossurais , Perna (Membro) , Atletas , Autoenxertos , Fêmur/cirurgia , Humanos , Estudos Retrospectivos , Volta ao Esporte , Tíbia/cirurgia
10.
Foot Ankle Surg ; 28(2): 166-175, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33766498

RESUMO

AIMS: To compare the outcomes of early and standard rehabilitation protocols following tendon transfers in the foot and ankle using interference screw fixation (ISF). METHODS: A systematic review was performed for relevant articles (1998 to 2020) reporting foot tendon transfer using ISF in adults. The primary outcome was early tendon failure. Secondary outcomes included function and complications. RESULTS: In total, 21 studies met the inclusion criteria, totalling 494 patients. Seven studies reported early rehabilitation protocols. The rate of early tendon failure was zero for each protocol and studies consistently reported a significant improvement in function. No differences were found comparing different rehabilitation protocols for tendon transfer for Achilles tendon pathology and foot drop. CONCLUSION: Both early and standard rehabilitation protocols are associated with high patient satisfaction and low complication rates, but currently there is a lack of evidence to support early loaded activities or motion. LEVEL OF EVIDENCE: IV Systematic review including case series.


Assuntos
Tendão do Calcâneo , Transferência Tendinosa , Tendão do Calcâneo/cirurgia , Adulto , Tornozelo/cirurgia , Parafusos Ósseos , Humanos , Ruptura/cirurgia , Transferência Tendinosa/métodos , Resultado do Tratamento
11.
Eur J Orthop Surg Traumatol ; 32(1): 151-157, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33763770

RESUMO

BACKGROUND: Trapeziectomy with ligament reconstruction and tendon interposition (LRTI) is currently the most popular technique for treating primary osteoarthritis of the thumb carpometacarpal joint. However, reduced trapezial height has sometimes been reported after LRTI. Longer immobilization and delayed rehabilitation times are also problematic. In this study, we evaluated the clinical and radiological outcomes of patients who underwent our modified LRTI procedure. METHODS: Retrospective study included 26 thumbs in 24 cases with advanced stages. Our modified Burton's procedure was as follows: (1) trapeziectomy was limited to distal-half, (2) the entire flexor carpi radialis (FCR) was harvested from the forearm, and (3) half-slip of the FCR tendon was stabilized by interference screw in the first metacarpal bone tunnel. RESULTS: Pain on the visual analogue scale (VAS), the quick Disabilities of the Arm Shoulder and Hand score, tip pinch strength significantly improved postoperatively. The preoperative height of the trapezial space was well-maintained at final follow-up. Magnetic resonance imaging at the one-year follow-up showed the existence of FCR tendon ball in 15 cases. Eighteen housewives resumed their daily activities after a mean period of 10 days postoperative, while another 6 patients returned to their original jobs after 3 weeks. CONCLUSIONS: Our modified LRTI method involves distal-half trapeziectomy and entire FCR interposition. A sewn FCR tendon ball always provide enough volume to fill the trapeziectomy space, which helps to prevent sinking of the metacarpal bone. Our technique produced sufficient ligamentoplasty and allowed early mobilization after surgery.


Assuntos
Articulações Carpometacarpais , Osteoartrite , Trapézio , Artroplastia , Parafusos Ósseos , Articulações Carpometacarpais/cirurgia , Antebraço , Humanos , Ligamentos , Osteoartrite/cirurgia , Estudos Retrospectivos , Tendões/cirurgia , Polegar/cirurgia , Trapézio/cirurgia
12.
Eur J Orthop Surg Traumatol ; 32(4): 759-765, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34125380

RESUMO

PURPOSE: The aims of the present study were to compare the biomechanical properties of tibial fixation in hamstring-graft ACL reconstruction using interference screw and a novel combination interference screw and dowel construct. MATERIAL AND METHODS: We compared the fixation of 30 (2- and 4-stranded gracilis and semitendinosis tendons) in 15 fresh-frozen porcine tibiae with a biocomposite resorbable interference screw (Group 1) and a screw and dowel construct (Group 2). Each graft was subjected to load-to-failure testing (50 mm/min) to determine maximum load, displacement at failure and pullout strength. RESULTS: There were no significant differences between the biomechanical properties of the constructs. Multivariate analysis demonstrated that combination constructs (ß = 140.20, p = 0.043), screw diameter (ß = 185, p = 0.006) and 4-strand grafts (ß = 51, p = 0.050) were associated with a significant increase in load at failure. Larger screw diameter was associated with increased construct stiffness (ß = 20.15, p = 0.020). CONCLUSION: The screw and dowel construct led to significantly increased fixation properties compared to interference screws alone in a porcine model. Increased screw diameter and utilization of 4-strand ACL grafts also led to improvement in load-to-failure of the construct. However, this is an in vitro study and additional investigations are needed to determine whether the results are reproducible in vivo. LEVEL OF EVIDENCE: Level V; Biomechanical study.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Parafusos Ósseos , Animais , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos , Humanos , Suínos , Tendões/transplante , Tíbia/cirurgia
13.
BMC Musculoskelet Disord ; 22(1): 498, 2021 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-34051767

RESUMO

BACKGROUND: The interference screw is the most popular device that fixes the graft for anterior cruciate ligament reconstruction, reducing the incidence of windshield effect and bungee effect. For the screw, either metallic, "bioresorbable," or polyetheretherketone (PEEK) material is available. PEEK is popular and extensively used due to its stability, biocompatibility, radiolucency, and elastic modulus. Rare relevant complications were reported, but here, we report two cases of extra-articular migrations of PEEK interference screw from the tibial tunnel after anterior cruciate reconstruction. CASE REPORT: An 18-year-old boy and a 56-year-old woman underwent anterior cruciate ligament reconstruction using a PEEK interference screw to fix the graft in the tibial tunnel. They suffered from screw extrusion from the tibial tunnel after 40 days and six months, respectively, with an incision rupture or palpable subcutaneous mass. They underwent a second operation and recovered well. CONCLUSIONS: The exact incidence of extra-articular migrations of PEEK interference screws is unknown, but it seems to be quite low; despite this and its uncertain cause, the negative effects caused by the PEEK material need to be considered.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Adolescente , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/efeitos adversos , Benzofenonas , Parafusos Ósseos/efeitos adversos , Feminino , Humanos , Cetonas/efeitos adversos , Masculino , Pessoa de Meia-Idade , Polietilenoglicóis , Polímeros
14.
BMC Musculoskelet Disord ; 22(1): 1047, 2021 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-34930185

RESUMO

BACKGROUND: Bone and Site Hold Tendon Inside (BASHTI) technique is an organic implant-less technique for anterior cruciate ligament (ACL) reconstruction with some clinical advantages, such as speeding up the healing process, over implantable techniques. The study aims to compare the mechanical properties of BASHTI technique with the conventional interference screw technique. METHODS: To investigate the mechanical properties, 20 in-vitro experimental tests were conducted. Synthetic dummy bone, along with fresh digital bovine tendons, as a graft, were used for experiments. Three loading steps were applied to all specimens, including a preconditioning, a main cyclic, and a pull-out loading. RESULTS: The mechanical characters of an interference screw technique using an 8 mm tendon diameter, including fixation strength, average cyclic stiffness (ACS), and average pull-out stiffness (APS) were found to be 439 ± 132 N, 10.3 ± 5.3 kN/mm, and 109 ± 40 N/mm, respectively. In the case of an interference screw using a 9 mm tendon, the fixation strength, ACS, and APS were obtained 549 ± 87 N, 10.3 ± 4.7 kN/mm, and 91 ± 13 N/mm, respectively. In parallel, the fixation strength, APS, and ACS of BASHTI technique using an 8 mm tendon were 360 ± 123 N, 3.3 ± 0.6 kN/mm, and 79 ± 27 N/mm, respectively, while, for 9 mm tendon 278 ± 103 N, 2.4 ± 1.2 kN/mm, and 111 ± 40 N/mm, were reported for fixation strength, APS, and ACS respectively when BASHTI technique was used. CONCLUSION: About 50% of interference screw samples showed superior mechanical properties compared to BASHTI technique, but in another half of the samples, the differences were not significant (N.S.). However, due to organic advantages of BASHTI technique and lower cost, it could be used as a substitute for interference screw technique, especially where fast recovery is expected.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Animais , Parafusos Ósseos , Bovinos , Humanos
15.
BMC Musculoskelet Disord ; 22(1): 556, 2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34144682

RESUMO

BACKGROUND: Superior biomechanical performance of tapered interference screws, compared with non-tapered screws, with reference to the anterior cruciate ligament (ACL) reconstruction process, has been reported in the literature. However, the effect of tapered interference screw's body slope on the initial stability of ACL is poorly understood. Thus, the main goal of this study was to investigate the effect of the interference screw's body slope on the initial stability of the reconstructed ACL. METHODS: Based on the best screw-bone tunnel diameter ratios in non-tapered screws, two different tapered interference screws were designed and fabricated. The diameters of both screws were equal to bone tunnel diameter in one-third of their length from screw tip, then they were gradually increased by 1mm, in the lower slope (LSTIS), and 2 mm, in the higher slope (HSTIS) screws. To simulate the ACL reconstruction, sixteen soft tissue grafts were fixed, using HSTIS and LSTIS, in synthetic bone blocks. Through applying sub-failure cyclic incremental tensile load, graft-bone-screw construct's stiffness and graft laxity in each cycle, also through applying subsequent step of loading graft to the failure, maximum load to failure, and graft's mode of failure were determined. Accordingly, the performance of the fabricated interference screws was compared with each other. RESULTS: HSTIS provides a greater graft-bone-screw construct stiffness, and a lower graft laxity, compared to LSTIS. Moreover, transverse rupture of graft fibers for LSTIS, and necking of graft in the HSTIS group were the major types of grafts' failure. CONCLUSIONS: HSTIS better replicates the intact ACL's behavior, compared to LSTIS, by causing less damage in graft's fibers; reducing graft laxity; and increasing fixation stability. Nonetheless, finding the optimal slope remains as an unknown and can be the subject of future studies.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/diagnóstico por imagem , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Tendões , Tíbia/cirurgia
16.
Sensors (Basel) ; 21(19)2021 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-34640951

RESUMO

Numerous methods and devices are available for implant fixation in anterior cruciate ligament (ACL) reconstruction. Biomechanical data indicate high variability in fixation stability across different devices. This study aims to provide a better insight into measuring the structural characteristics and mechanical behavior of ACL implant fixations. Fourteen human tibial specimens with reconstructed ACLs were subjected to progressively increasing dynamic loading until failure. The motions of the tibia, the proximal and distal graft ends, as well as the testing frame and actuator, were continuously recorded via a motion tracking system. Significantly higher displacements of the machine actuator (1.0 mm at graft slippage onset, and 12.2 mm at ultimate load) were measured compared to the displacements of the proximal (0.8 and 4.3 mm, respectively) and distal graft (0.1 and 3.4 mm, respectively) ends. The displacements measured at different sites showed significant correlations. The provided data suggest significant and systematic inaccuracies in the stiffness and slippage of the fixation when using machine displacement, as commonly reported in the literature. The assessment of the distal graft displacement excludes the artifactual graft elongation, and most accurately reflects the graft slippage onset indicating clinical failure. Considering the high displacement at the ultimate load, the ultimate load could be used as a standardized variable to compare different fixation methods. However, the ultimate load alone is not sufficient to qualitatively describe fixation stability.


Assuntos
Reconstrução do Ligamento Cruzado Anterior , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Parafusos Ósseos , Humanos , Tíbia/cirurgia
17.
J Biol Regul Homeost Agents ; 34(4 Suppl. 3): 377-391. Congress of the Italian Orthopaedic Research Society, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33261302

RESUMO

Transtibial femoral tunnel drilling is still an alternative technique in ACL reconstruction. Femoral interference screw divergence is a potential pitfall associated with transtibial tunnel technique, as angles greater than 15° jeopardize graft fixation. Our mathematical model theorizes the proper degrees of knee flexion during femoral screw insertion and the correct screwdriver position to obtain a minimal divergence of the screw in the femoral tunnel. The cadaveric study confirms our method. Mathematical model: using rototranslation matrices, a correlation is demonstrated between the ACLtibial- guide angle, the knee flexion, and the screwdriver position. A theoretical minimal divergence between femoral interference screw and the femoral tunnel is obtainable following these assumptions: 1) knee hyperflexion during femoral screw insertion is obtained adding a flexion corresponding to the ACL-tibial-guide angle to the flexion while drilling the femoral tunnel; 2) screwdriver position (through the AM portal) is kept parallel to tibial plateau at a rotation of 15° medial to tibial sagittal plane. Cadaveric study: 24 cadaver knees were used. The transtibial tunnel was drilled with an 8 mm drill bit with the help of an ACL tibial guide set at 55°. To simulate femoral tunnel direction, a 2.4 mm K. wire was drilled through the femur with a transtibial 7 mm offset femoral drill guide. To simulate the femoral screw direction, a second 2.4 mm K. wire was drilled from the femoral entry point of the first wire through the femur, with a cannulated screwdriver. Screwdriver direction and knee flexion during the simulation were obtained following two different methods: GROUP A (mathematical model group, 12 knees), screwdriver direction and knee flexion were calculated following the mathematical model; in GROUP B (control group, 12 knees), knee hyperflexion and screwdriver medialization were manually obtained by a senior surgeon. The divergence between the femoral interference screw and the femoral tunnel was identified as the angle formed by the two wires, measured on the plane formed by the direction of the wires. Mean divergence angles between the K. wires were significantly different (p< 0.05) between the groups: GROUP 1 (mathematical rule): 7.25° (SD 2.2); GROUP 2 (free-hand technique): 17.3° (SD 2.9). Our study shows that a minimal divergence between the femoral tunnel and the screwdriver can be achieved simply by following a mathematical rule for correct intraoperative knee flexion and screwdriver position without the need for any specialized instrumentation. Namely, during femoral interference screw insertion through the anteromedial portal: 1) the correct knee flexion is the sum between the knee flexion angle while drilling the transtibial femoral tunnel AND the ACL tibial guide angle used during tibial tunnel drilling; 2) Correct screwdriver position is parallel to the tibial plateau, engaging the femoral tunnel with a position of 15° medial to tibial sagittal plane. This simple concept has clinical relevance in helping the surgeons in obtaining an optimal alignment between the femoral tunnel and the femoral interference screw during transtibial ACL reconstruction. Furthermore, following the assumptions of this study, a starting knee flexion angle around 70° during femoral tunnel drilling seems preferable for ACL reconstruction when the transtibial tunnel technique is used. Indeed, because ACL-tibial-guide angles range commonly from 50° to 60° and in vivo, the maximal intraoperative knee flexion attainable is 130°, a starting knee flexion around 70° is optimal to allows for adding flexion angles up to 60° before reaching the physiological limit value of 130°.


Assuntos
Fêmur , Ligamento Cruzado Anterior/cirurgia , Parafusos Ósseos , Cadáver , Fêmur/cirurgia , Humanos , Articulação do Joelho/cirurgia , Tíbia/cirurgia
18.
Knee Surg Sports Traumatol Arthrosc ; 28(1): 320-325, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29627930

RESUMO

PURPOSE: To assess whether early rehabilitation could be safe after flexor digitorum longus (FDL) tendon transfer, the current biomechanical study aimed to measure tendon displacement under cyclic loading and load to failure, comparing a traditional tendon-to-tendon (TT) repair with interference screw fixation (ISF). METHODS: 24 fresh-frozen cadaveric below knee specimens underwent FDL tendon transfer. In 12 specimens a TT repair was performed via a navicular bone tunnel. In a further 12 specimens ISF was performed. Using a materials testing machine, the FDL tendon was cycled 1000 times to 150 N and tendon displacement at the insertion site measured. A final load to failure test was then performed. Statistical analysis was performed using two-way ANOVA and an independent t test, with a significance level of p < 0.05. RESULT: No significant difference in tendon displacement occurred after cyclic loading, with mean tendon displacements of 1.9 ± 1.2 mm (mean ± SD) in the TT group and 1.8 ± 1.5 mm in the ISF group (n.s.). Two early failures occurred in the ISF group, none in the TT group. Mean load to failure was significantly greater following TT repair (459 ± 96 N), compared with ISF (327 ± 76 N), p = 0.002. CONCLUSION: Minimal tendon displacement of less than 2 mm occurred during cyclic testing in both groups. The two premature failures and significantly reduced load to failure observed in the ISF group, however, indicate that the traditional TT technique is more robust. Regarding clinical relevance, this study suggests that early active range of motion and protected weight bearing may be safe following FDL tendon transfer for stage 2 tibialis posterior tendon dysfunction.


Assuntos
Ossos do Tarso/cirurgia , Transferência Tendinosa/métodos , Adulto , Fenômenos Biomecânicos , Parafusos Ósseos , Pé/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Tendões/cirurgia , Suporte de Carga
19.
Knee Surg Sports Traumatol Arthrosc ; 28(1): 124-131, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31240379

RESUMO

PURPOSE: A bone tunnel is often used during the reconstruction of the anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL). The purpose of this study is to compare proposed directions for drilling this fibular tunnel and to assess potential tunnel length, using a 5-mm-diameter tunnel and surrounding bone. METHODS: Anonymous DICOM data from spiral CT-scan images of the ankle were obtained from 12 Caucasian patients: 6 females and 6 males. Virtual tunnels were generated in a 3D bone model with angles of 30°, 45°, 60° and 90° in relation to the fibular long axis. Several measurements were performed: distance from entrance to perforation of opposing cortex, shortening of the tunnel, distance from tunnel centre to bone surface. RESULTS: A tunnel in a perpendicular direction resulted in an average possible tunnel length of 16.8 (± 2.7) mm in the female group and 20.3 (± 3.4) mm in the male group. A tunnel directed at 30° offered the longest length: 30.9 (± 2.5) mm in the female group and 34.4 (± 2.9) mm in the male group. The use of a 5-mm-diameter tunnel in a perpendicular direction caused important shortening of the tunnel at the entrance in some cases. The perpendicular tunnel was very near to the digital fossa while the most obliquely directed tunnels avoided this region. CONCLUSION: An oblique tunnel allows for a longer tunnel and avoids the region of the digital fossa, thereby retaining more surrounding bone. In addition, absolute values of tunnel length are given, which can be useful when considering the use of certain implants. We recommend drilling an oblique fibular tunnel when reconstructing the ATFL and CFL.


Assuntos
Articulação do Tornozelo/cirurgia , Fíbula/cirurgia , Instabilidade Articular/cirurgia , Ligamentos Laterais do Tornozelo/cirurgia , Procedimentos Ortopédicos/métodos , Adulto , Traumatismos do Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Feminino , Fíbula/diagnóstico por imagem , Humanos , Ligamentos Laterais do Tornozelo/diagnóstico por imagem , Ligamentos Laterais do Tornozelo/lesões , Masculino , Pessoa de Meia-Idade , Entorses e Distensões/cirurgia , Tomografia Computadorizada Espiral , Adulto Jovem
20.
J Shoulder Elbow Surg ; 29(7): 1435-1439, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32113864

RESUMO

BACKGROUND: Many biceps tenodesis (BT) procedures are described for treating proximal biceps pathology. Axillary nerve injury has been reported during BT using bicortical drilling techniques with variable results depending on the location. In addition, there is a risk of potential articular damage during suprapectoral BT. We sought to determine the distance between the axillary nerve and the posterior passage of a bicortical pin, as well as the risk of articular damage, and to analyze whether a lateral inclination of the pin could avoid the chondral risk during suprapectoral BT with bicortical drilling. METHODS: Ten cadaveric shoulders were divided into 2 groups. In the first group, we determined the axillary nerve distance from the posterior exit point of 3 pins in a suprapectoral position 15 mm distal to the humeral cartilage: perpendicular, 10° caudal, and 20° caudal inclination. We measured 2 distances from the pin: to the axillary nerve and to the cartilage border. In the second group, we set one pin at the same perpendicular position and set the second pin 15° laterally tilted to determine its extra-articular passage. RESULTS: No pin injured the nerve, whereas all pins showed a transchondral direction. The 20° caudal inclination was the nearest to the nerve (18.8 mm [95% confidence interval, 5.5-32 mm]), but the perpendicular position was the safer position (38.8 mm [95% confidence interval, 28-49.6 mm]). Tilting the pin direction 15° laterally prevented cartilage damage (P = .008). CONCLUSIONS: Suprapectoral BT with bicortical drilling performed 15 mm distal to the humeral cartilage is a safe procedure regarding the axillary nerve. A potential humeral chondral injury could be prevented with 15° of lateral inclination of the pin guide.


Assuntos
Pinos Ortopédicos , Traumatismos dos Nervos Periféricos/prevenção & controle , Tenodese/métodos , Braço , Plexo Braquial , Cadáver , Feminino , Humanos , Úmero/cirurgia , Pessoa de Meia-Idade , Músculo Esquelético/cirurgia , Traumatismos dos Nervos Periféricos/etiologia , Procedimentos de Cirurgia Plástica , Tenodese/efeitos adversos , Tenodese/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA