Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.591
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(4): e2212227120, 2023 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-36652475

RESUMO

Propagating spatiotemporal neural patterns are widely evident across sensory, motor, and association cortical areas. However, it remains unclear whether any characteristics of neural propagation carry information about specific behavioral details. Here, we provide the first evidence for a link between the direction of cortical propagation and specific behavioral features of an upcoming movement on a trial-by-trial basis. We recorded local field potentials (LFPs) from multielectrode arrays implanted in the primary motor cortex of two rhesus macaque monkeys while they performed a 2D reach task. Propagating patterns were extracted from the information-rich high-gamma band (200 to 400 Hz) envelopes in the LFP amplitude. We found that the exact direction of propagating patterns varied systematically according to initial movement direction, enabling kinematic predictions. Furthermore, characteristics of these propagation patterns provided additional predictive capability beyond the LFP amplitude themselves, which suggests the value of including mesoscopic spatiotemporal characteristics in refining brain-machine interfaces.


Assuntos
Interfaces Cérebro-Computador , Córtex Motor , Animais , Macaca mulatta , Fenômenos Biomecânicos , Movimento , Potenciais de Ação
2.
J Exp Bot ; 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38970333

RESUMO

Autopolyploidization, which refers to a polyploidization via genome duplication without a hybridization, promotes growth in autotetraploids, but suppresses growth in high-polyploids (autohexaploids or autooctoploids). The mechanism underlying this growth suppression (i.e., "high-ploidy syndrome") has not been comprehensively characterized. In this study, we conducted a kinematic analysis of the root apical meristem cells in Arabidopsis thaliana autopolyploids (diploid, tetraploid, hexaploid, and octoploid) to determine the effects of the progression of genome duplication on root growth. The results of the root growth analysis showed that tetraploidization increases the cell volume, but decreases cell proliferation. However, cell proliferation and volume growth are suppressed in high-polyploids. The whole-mount fluorescence in situ hybridization analysis revealed extensive chromosome polytenization in the region where cell proliferation does not usually occur in the high-polyploid roots, which is likely at least partly correlated with the suppression of endoreduplication. The study findings suggest that chromosome polytenization is important for the suppressed growth of high-polyploids.

3.
Cerebellum ; 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38761352

RESUMO

Substantial evidence highlights the role of the cerebellum in the pathophysiology of tremor in essential tremor (ET), although its potential involvement in altered movement execution in this condition remains unclear. This study aims to explore potential correlations between the cerebellum and basal ganglia functional connectivity and voluntary movement execution abnormalities in ET, objectively assessed with kinematic techniques. A total of 20 patients diagnosed with ET and 18 healthy subjects were enrolled in this study. Tremor and repetitive finger tapping were recorded using an optoelectronic kinematic system. All participants underwent comprehensive 3T-MRI examinations, including 3D-T1 and blood-oxygen-level dependent (BOLD) sequences during resting state. Morphometric analysis was conducted on the 3D-T1 images, while a seed-based analysis was performed to investigate the resting-state functional connectivity (rsFC) of dorsal and ventral portions of the dentate nucleus and the external and internal segments of the globus pallidus. Finally, potential correlations between rsFC alterations in patients and clinical as well as kinematic scores were assessed. Finger tapping movements were slower in ET than in healthy subjects. Compared to healthy subjects, patients with ET exhibited altered FC of both dentate and globus pallidus with cerebellar, basal ganglia, and cortical areas. Interestingly, both dentate and pallidal FC exhibited positive correlations with movement velocity in patients, differently from that we observed in healthy subjects, indicating the higher the FC, the faster the finger tapping. The findings of this study indicate the possible role of both cerebellum and basal ganglia in the pathophysiology of altered voluntary movement execution in patients with ET.

4.
J Exp Biol ; 227(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38752366

RESUMO

The evolution and utilization of limbs facilitated terrestrial vertebrate movement on land, but little is known about how other lateral structures enhance terrestrial locomotion in amphibian fishes without terrestrialized limb structures. Climbing perch (Anabas testudineus) exhibit sustained terrestrial locomotion using uniaxial rotating gill covers instead of appendages. To investigate the role of such simple lateral structures in terrestrial locomotion and the motion-generating mechanism of the corresponding locomotor structure configuration (gill covers and body undulation), we measured the terrestrial kinematics of climbing perch and quantitatively analysed its motion characteristics. The digitized locomotor kinematics showed a unique body postural adjustment ability that enables the regulation of the posture of the caudal peduncle for converting lateral bending force into propulsion. An analysis of the coordination characteristics demonstrated that the motion of the gill cover is kinematically independent of axial undulation, suggesting that the gill cover functions as an anchored simple support pole while axial undulation actively mediates body posture and produces propulsive force. The two identified feature shapes explained more than 87% of the complex lateral undulation in multistage locomotion. The kinematic characteristics enhance our understanding of the underlying coordinating mechanism corresponding to locomotor configurations. Our work provides quantitative insight into the terrestrial locomotor adaptation of climbing perch and sheds light on terrestrial motion potential of locomotor configurations containing a typical aquatic body and restricted lateral structure.


Assuntos
Locomoção , Percas , Animais , Locomoção/fisiologia , Fenômenos Biomecânicos , Percas/fisiologia , Brânquias/fisiologia
5.
Exp Brain Res ; 2024 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-38980340

RESUMO

Noise is a ubiquitous component of motor systems that leads to behavioral variability of all types of movements. Nonetheless, systems-based models investigating human movements are generally deterministic and explain only the central tendencies like mean trajectories. In this paper, a novel approach to modeling kinematic variability of movements is presented and tested on the oculomotor system. This approach reconciles the two prominent philosophies of saccade control: displacement-based control versus velocity-based control. This was achieved by quantifying the variability in saccadic eye movements and developing a stochastic model of its control. The proposed stochastic dual model generated significantly better fits of inter-trial variances of the saccade trajectories compared to existing models. These results suggest that the saccadic system can flexibly use the information of both desired displacement and velocity for its control. This study presents a potential framework for investigating computational principles of motor control in the presence of noise utilizing stochastic modeling of kinematic variability.

6.
Biomed Eng Online ; 23(1): 16, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326806

RESUMO

BACKGROUND: Previous studies have reported that abnormal interlimb coordination is a typical characteristic of motor developmental delay (MDD) during human movement, which can be visually manifested as abnormal motor postures. Clinically, the scale assessments are usually used to evaluate interlimb coordination, but they rely heavily on the subjective judgements of therapists and lack quantitative analysis. In addition, although abnormal interlimb coordination of MDD have been studied, it is still unclear how this abnormality is manifested in physiology-related kinematic features. OBJECTIVES: This study aimed to evaluate how abnormal interlimb coordination of MDD during infant crawling was manifested in the stability of joints and limbs, activation levels of synergies and intrasubject consistency from the kinematic synergies of tangential velocities of joints perspective. METHODS: Tangential velocities of bilateral shoulder, elbow, wrist, hip, knee and ankle over time were computed from recorded three-dimensional joint trajectories in 40 infants with MDD [16 infants at risk of developmental delay, 11 infants at high risk of developmental delay, 13 infants with confirmed developmental delay (CDD group)] and 20 typically developing infants during hands-and-knees crawling. Kinematic synergies and corresponding activation coefficients were derived from those joint velocities using the non-negative matrix factorization algorithm. The variability accounted for yielded by those synergies and activation coefficients, and the synergy weightings in those synergies were used to measure the stability of joints and limbs. To quantify the activation levels of those synergies, the full width at half maximum and center of activity of activation coefficients were calculated. In addition, the intrasubject consistency was measured by the cosine similarity of those synergies and activation coefficients. RESULTS: Interlimb coordination patterns during infant crawling were the combinations of four types of single-limb movements, which represent the dominance of each of the four limbs. MDD mainly reduced the stability of joints and limbs, and induced the abnormal activation levels of those synergies. Meanwhile, MDD generally reduced the intrasubject consistency, especially in CDD group. CONCLUSIONS: These features have the potential for quantitatively evaluating abnormal interlimb coordination in assisting the clinical diagnosis and motor rehabilitation of MDD.


Assuntos
Articulação do Cotovelo , Movimento , Humanos , Lactente , Fenômenos Biomecânicos , Movimento/fisiologia , Joelho , Mãos
7.
Int J Eat Disord ; 57(3): 624-634, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38263753

RESUMO

OBJECTIVE: Food avoidance is central to patients with anorexia nervosa-restrictive type (AN-R). Competing accounts in experimental psychopathology research suggest that food avoidance may result from automatic, habitual responses or from elevated inhibitory control abilities. This study investigated behavioral trajectories of food avoidance in a novel virtual reality stopping task. METHOD: Sixty patients with AN-R and 29 healthy controls with normal weight were investigated using a novel, kinematic task in virtual reality. We recorded spatial displacement in stop- and go-trials to virtual food and control objects. Inhibitory control abilities were operationalized by the VR task in stopping performance (i.e., interrupted movement in stop-trials), whereas we also measured habitual avoidance of virtual food across both go- and stop-trials (i.e., delayed movement relative to nonfood objects). RESULTS: In patients with AN-R, hand displacements were shorter to food versus nonfood across stop- and go-trials, reflected in a Stimulus × Group interaction. Healthy controls showed no differences. Importantly, the food-specific effect in AN-R was identical across stop- and go-trials, indicating habitual food avoidance. Moreover, stop error rates (i.e., stop-trials with response) were lower in patients with AN-R. DISCUSSION: The findings suggest food-specific habitual avoidance and heightened generalized inhibitory control in AN-R. The continuously delayed displacements during active hand movements across stop- and go-trials indicated the persistence of patients' avoidance of food. PUBLIC SIGNIFICANCE: Experimental research investigates the mechanisms underlying mental disorders such as anorexia nervosa. In this study, we measured interrupted hand movements in response to food pictures or neutral pictures (shoes) in patients with anorexia nervosa and healthy controls. A virtual reality scenario was used. Findings indicated that patients were slower at approaching food, interrupted or not. Key mechanisms of food avoidance can be translated into habit-based treatment options in future research.


Assuntos
Anorexia Nervosa , Humanos , Anorexia Nervosa/terapia , Alimentos , Hábitos , Atenção , Aprendizagem da Esquiva/fisiologia
8.
Plant Cell Rep ; 43(2): 38, 2024 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-38200224

RESUMO

KEY MESSAGE: A novel non-steady-state kinematic analysis shows differences in cell division and expansion determining a better recovery from a 3-day cold spell in emerged compared to non-emerged maize leaves. Zea mays is highly sensitive to chilling which frequently occurs during its seedling stage. Although the direct effect of chilling is well studied, the mechanisms determining the subsequent recovery are still unknown. Our goal is to determine the cellular basis of the leaf growth response to chilling and during recovery of leaves exposed before or after their emergence. We first studied the effect of a 3-day cold spell on leaf growth at the plant level. Then, we performed a kinematic analysis to analyse the dynamics of cell division and elongation during recovery of the 4th leaf after exposure to cold before or after emergence. Our results demonstrated cold more strongly reduced the final length of non-emerged than emerged leaves (- 13 vs. - 18%). This was not related to growth differences during cold, but a faster and more complete recovery of the growth of emerged leaves. This difference was due to a higher cell division rate on the 1st and a higher cell elongation rate on the 2nd day of recovery, respectively. The dynamics of cell division and expansion during recovery determines developmental stage-specific differences in cold tolerance of maize leaves.


Assuntos
Folhas de Planta , Zea mays , Divisão Celular , Proliferação de Células , Ciclo Celular
9.
Neurol Sci ; 45(5): 2035-2046, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38091213

RESUMO

BACKGROUND: Opicapone (OPC) is a third-generation, selective peripheral COMT inhibitor that improves peripheral L-DOPA bioavailability and reduces OFF time and end-of-dose motor fluctuations in Parkinson's disease (PD) patients. OBJECTIVES: In this study, we objectively assessed the effects of adding OPC to L-DOPA on bradykinesia in PD through kinematic analysis of finger movements. METHODS: We enrolled 20 treated patients with PD and motor fluctuations. Patients underwent two experimental sessions (L-DOPA, L-DOPA + OPC), separated by at least 1 week. In each session, patients were clinically evaluated and underwent kinematic movement analysis of repetitive finger movements at four time points: (i) before their usual morning dose of L-DOPA (T0), (ii) 30 min (T1), (iii) 1 h and 30 min (T2), and (iv) 3 h and 30 min after the L-DOPA intake (T3). RESULTS: Movement velocity and amplitude of finger movements were higher in PD patients during the session with OPC compared to the session without OPC at all the time points tested. Importantly, the variability of finger movement velocity and amplitude across T0-T3 was significantly lower in the L-DOPA + OPC than L-DOPA session. CONCLUSIONS: This study is the first objective assessment of the effects of adding OPC to L-DOPA on bradykinesia in patients with PD and motor fluctuations. OPC, in addition to the standard dopaminergic therapy, leads to significant improvements in bradykinesia during clinically relevant periods associated with peripheral L-DOPA dynamics, i.e., the OFF state in the morning, delayed-ON, and wearing-OFF periods.


Assuntos
Oxidiazóis , Doença de Parkinson , Humanos , Doença de Parkinson/complicações , Doença de Parkinson/tratamento farmacológico , Levodopa/efeitos adversos , Antiparkinsonianos/uso terapêutico , Hipocinesia/tratamento farmacológico , Hipocinesia/etiologia , Fenômenos Biomecânicos , Inibidores de Catecol O-Metiltransferase/farmacologia , Inibidores de Catecol O-Metiltransferase/uso terapêutico
10.
Arch Phys Med Rehabil ; 105(4): 673-681.e2, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37981256

RESUMO

OBJECTIVE: To investigate the validity and test-retest reliability of a customized markerless motion capture (MMC) system that used iPad Pros with a Light Detection And Ranging scanner at two different viewing angles to measure the active range of motion (AROM) and the angular waveform of the upper-limb-joint angles of healthy adults performing functional tasks. DESIGN: Participants were asked to perform shoulder and elbow actions for the investigator to take AROM measurements, followed by four tasks that simulated daily functioning. Each participant attended 2 experimental sessions, which were held at least 2 days and at most 14 days apart. SETTING: A Vicon system and 2 iPad Pros installed with our MMC system were placed at 2 different angles to the participants and recorded their movements concurrently during each task. PARTICIPANTS: Thirty healthy adults (mean age: 28.9, M/F ratio: 40/60). INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: The AROM and the angular waveform of the upper-limb-joint angles. RESULTS: The iPad Pro MMC system underestimated the shoulder joint and elbow joint angles in all four simulated functional tasks. The MMC demonstrated good to excellent test-retest reliability for the shoulder joint AROM measurements in all 4 tasks. CONCLUSIONS: The maximal AROM measurements calculated by the MMC system had consistently smaller values than those measured by the goniometer. An MMC in iPad Pro system might not be able to replace conventional goniometry for clinical ROM measurements, but it is still suggested for use in home-based and telerehabilitation training for intra-subject measurements because of its good reliability, low cost, and portability. Further development to improve its performance in motion capture and analysis in disease populations is warranted.


Assuntos
Captura de Movimento , Extremidade Superior , Adulto , Humanos , Projetos Piloto , Fenômenos Biomecânicos , Reprodutibilidade dos Testes , Amplitude de Movimento Articular
11.
Eur J Appl Physiol ; 124(3): 975-991, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37755580

RESUMO

For whole-body sway patterns, a compound motor response following an external stimulus may comprise reflexes, postural adjustments (anticipatory or compensatory), and voluntary muscular activity. Responses to equilibrium destabilization may depend on both motor set and a subject`s expectation of the disturbing stimulus. To disentangle these influences on lower limb responses, we studied a model in which subjects (n = 14) were suspended in the air, without foot support, and performed a fast unilateral wrist extension (WE) in response to a passive knee flexion (KF) delivered by a robot. To characterize the responses, electromyographic activity of rectus femoris and reactive leg torque was obtained bilaterally in a series of trials, with or without the requirement of WE (motor set), and/or beforehand information about the upcoming velocity of KF (subject`s expectation). Some fast-velocity trials resulted in StartReact responses, which were used to subclassify leg responses. When subjects were uninformed about the upcoming KF, large rectus femoris responses concurred with a postural reaction in conditions without motor task, and with both postural reaction and postural adjustment when WE was required. WE in response to a low-volume acoustic signal elicited no postural adjustments. When subjects were informed about KF velocity and had to perform WE, large rectus femoris responses corresponded to anticipatory postural adjustment rather than postural reaction. In conclusion, when subjects are suspended in the air and have to respond with WE, the prepared motor set includes anticipatory postural adjustments if KF velocity is known, and additional postural reactions if KF velocity is unknown.


Assuntos
Postura , Punho , Humanos , Postura/fisiologia , Eletromiografia , Reflexo , Extremidade Inferior , Equilíbrio Postural , Movimento/fisiologia , Músculo Esquelético/fisiologia
12.
Eur J Appl Physiol ; 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38953975

RESUMO

PURPOSE: Eccentric quasi-isometric (EQI) resistance training is emerging as a promising option in sports medicine and rehabilitation. Despite prior research on EQI contractions in quadriceps and biceps brachii, their use in hamstring injury contexts is underexplored. Therefore, our study examines and contrasts the biomechanics and fatigue effects of EQI training on knee extensors and flexors. METHODS: Following familiarization, 16 healthy, active participants (9 men, 7 women; 23.5 ± 2.6 years, 72.1 ± 12.8 kg, 173.4 ± 10.7 cm) performed, in random order, four EQI contractions for knee extensions and flexions, respectively. EQI contractions were isotonically loaded to 70% of concentric (60°·s-1) maximal voluntary contraction. Rest between repetitions was set at three minutes, while four minutes separated each muscle group. Peak torque, mean torque, and optimal angle were evaluated pre- and post-bouts. Inter-repetition contraction time and angular velocity were also assessed. RESULTS: Average torque was 160.9 ± 44.2 and 71.5 ± 23.2 Nm for the extensors and flexors. Peak and mean torque significantly decreased for both extensors (p < 0.001, d = 0.70-0.71) and flexors (p ≤ 0.022, d = 0.36) after EQI contractions, respectively. However, the optimal angle increased for extensors (p < 0.001, d = 1.00) but not flexors (p = 0.811, d = 0.06). During EQI contractions, knee flexors exhibited greater intra-repetition velocity than extensors (p = 0.002; η2 = 0.50). Decreases in inter-repetition time and range of motion were more consistent for the extensors. CONCLUSIONS: Distinct responses exist when comparing EQI contractions of the knee extensors and flexors, particularly their effect on peak torque angles. These findings suggest knee flexors may require lower relative intensities to align more closely with extensor EQI contractions.

13.
J Biomech Eng ; 146(11)2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-38959087

RESUMO

Goals of knee replacement surgery are to restore function and maximize implant longevity. To determine how well these goals are satisfied, tibial femoral kinematics and tibial contact kinematics are of interest. Tibiofemoral kinematics, which characterize function, is movement between the tibia and femur whereas tibial contact kinematics, which is relevant to implant wear, is movement of the location of contact by the femoral implant on the tibial articular surface. The purposes of this review article are to describe and critique relevant methods to guide correct implementation. For tibiofemoral kinematics, methods are categorized as those which determine (1) relative planar motions and (2) relative three-dimensional (3D) motions. Planar motions are determined by first finding anterior-posterior (A-P) positions of each femoral condyle relative to the tibia and tracking these positions during flexion. Of the lowest point (LP) and flexion facet center (FFC) methods, which are common, the lowest point method is preferred and the reasoning is explained. 3D motions are determined using the joint coordinate system (JCS) of Grood and Suntay. Previous applications of this JCS have resulted in motions which are largely in error due to "kinematic crosstalk." Requirements for minimizing kinematic crosstalk are outlined followed by an example, which demonstrates the method for identifying a JCS that minimizes kinematic crosstalk. Although kinematic crosstalk can be minimized, the need for a JCS to determine 3D motions is questionable based on anatomical constraints, which limit varus-valgus rotation and compression-distraction translation. Methods for analyzing tibial contact kinematics are summarized and validation of methods discussed.


Assuntos
Fêmur , Tíbia , Tíbia/fisiologia , Tíbia/diagnóstico por imagem , Fenômenos Biomecânicos , Humanos , Fluoroscopia , Fêmur/fisiologia , Fêmur/diagnóstico por imagem , Fenômenos Mecânicos , Articulação do Joelho/fisiologia , Articulação do Joelho/diagnóstico por imagem
14.
J Ultrasound Med ; 43(2): 375-383, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37987527

RESUMO

OBJECTIVES: A new ultrasound-based device is proposed to non-invasively measure the orientation of the scapula in the standing position to consider this parameter for Total Shoulder Arthroplasty. The aim of this study was to assess the accuracy and reliability of this device. METHODS: Accuracy was assessed by comparing measurements made with the ultrasound device to those acquired with a three-dimensional (3D) optical localization system (Northern Digital, Canada) on a dedicated mechanical phantom. Three users performed 10 measurements on three healthy volunteers with different body mass (BMI) indices to analyze the reliability of the device by measuring the intra and interobserver variabilities. RESULTS: The mean accuracy of the device was 0.9°± 0.7 (0.01-3.03), 1.3°± 0.8 (0.03-4.55), 1.9°± 1.5 (0.05-5.76), respectively, in the axial, coronal, and sagittal planes. The interobserver and intraobserver variabilities were excellent whatever the BMI and the users experience. CONCLUSIONS: The device is accurate and reliable enough for the measurement of the scapula orientation in the standing position.


Assuntos
Articulação do Ombro , Posição Ortostática , Humanos , Reprodutibilidade dos Testes , Escápula/diagnóstico por imagem , Variações Dependentes do Observador , Canadá , Articulação do Ombro/diagnóstico por imagem , Amplitude de Movimento Articular , Fenômenos Biomecânicos
15.
BMC Musculoskelet Disord ; 25(1): 415, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807086

RESUMO

BACKGROUND: Biomechanical alterations in patients with low back pain (LBP), as reduced range of motion or strength, do not appear to be exclusively related to the trunk. Thus, studies have investigated biomechanical changes in the hip, due to the proximity of this joint to the low back region. However, the relationship between hip biomechanical changes in patients with LBP is still controversial and needs to be summarized. Therefore, the aim of this study was to systematically review observational studies that used biomechanical assessments in patients with non-specific LBP. METHODS: The search for observational studies that evaluated hip biomechanical variables (i.e., range of motion, kinematic, strength, and electromyography) in adults with non-specific acute, subacute, and chronic LBP was performed in the PubMed, Embase, Cinahl and Sportdiscus databases on February 22nd, 2024. Four blocks of descriptors were used: 1) type of study, 2) LBP, 3) hip and 4) biomechanical assessment. Two independent assessors selected eligible studies and extracted the following data: author, year of publication, country, study objective, participant characteristics, outcomes, and results. The methodological quality of the studies was assessed using the Epidemiological Appraisal Instrument and classified as low, moderate, and high. Due to the heterogeneity of the biomechanical assessment and, consequently, of the results among eligible studies, a descriptive analysis was performed. RESULTS: The search strategy returned 338 articles of which 54 were included: nine articles evaluating range of motion, 16 evaluating kinematic, four strength, seven electromyography and 18 evaluating more than one outcome. The studies presented moderate and high methodological quality. Patients with LBP, regardless of symptoms, showed a significant reduction in hip range of motion, especially hip internal rotation, reduction in the time to perform functional activities such as sit-to-stance-to-sit, sit-to-stand or walking, greater activation of the hamstrings and gluteus maximus muscles and weakness of the hip abductor and extensor muscles during specific tests and functional activities compared to healthy individuals. CONCLUSION: Patients with LBP present changes in range of motion, task execution, activation, and hip muscle strength when compared to healthy individuals. Therefore, clinicians must pay greater attention to the assessment and management of the hip during the treatment of these patients. SYSTEMATIC REVIEW REGISTRATION: International Prospective Register of Systematic Reviews (PROSPERO) (CRD42020213599).


Assuntos
Eletromiografia , Articulação do Quadril , Dor Lombar , Amplitude de Movimento Articular , Humanos , Dor Lombar/fisiopatologia , Dor Lombar/diagnóstico , Fenômenos Biomecânicos/fisiologia , Amplitude de Movimento Articular/fisiologia , Articulação do Quadril/fisiopatologia , Força Muscular/fisiologia , Estudos Observacionais como Assunto , Músculo Esquelético/fisiopatologia
16.
Acta Neurochir (Wien) ; 166(1): 6, 2024 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-38214753

RESUMO

PURPOSE: Attaining sufficient microsurgical skills is paramount for neurosurgical trainees. Kinematic analysis of surgical instruments using video offers the potential for an objective assessment of microsurgical proficiency, thereby enhancing surgical training and patient safety. The purposes of this study were to develop a deep-learning-based automated instrument tip-detection algorithm, and to validate its performance in microvascular anastomosis training. METHODS: An automated instrument tip-tracking algorithm was developed and trained using YOLOv2, based on clinical microsurgical videos and microvascular anastomosis practice videos. With this model, we measured motion economy (procedural time and path distance) and motion smoothness (normalized jerk index) during the task of suturing artificial blood vessels for end-to-side anastomosis. These parameters were validated using traditional criteria-based rating scales and were compared across surgeons with varying microsurgical experience (novice, intermediate, and expert). The suturing task was deconstructed into four distinct phases, and parameters within each phase were compared between novice and expert surgeons. RESULTS: The high accuracy of the developed model was indicated by a mean Dice similarity coefficient of 0.87. Deep learning-based parameters (procedural time, path distance, and normalized jerk index) exhibited correlations with traditional criteria-based rating scales and surgeons' years of experience. Experts completed the suturing task faster than novices. The total path distance for the right (dominant) side instrument movement was shorter for experts compared to novices. However, for the left (non-dominant) side, differences between the two groups were observed only in specific phases. The normalized jerk index for both the right and left sides was significantly lower in the expert than in the novice groups, and receiver operating characteristic analysis showed strong discriminative ability. CONCLUSION: The deep learning-based kinematic analytic approach for surgical instruments proves beneficial in assessing performance in microvascular anastomosis. Moreover, this methodology can be adapted for use in clinical settings.


Assuntos
Aprendizado Profundo , Cirurgiões , Humanos , Movimento (Física) , Algoritmos , Anastomose Cirúrgica , Competência Clínica
17.
Artigo em Inglês | MEDLINE | ID: mdl-38932596

RESUMO

PURPOSE: The purpose of this study was to assess whether kinematic alignment (KA) outperforms mechanical alignment (MA) in restoring patellar tracking to native patterns by using a clustering algorithm. METHODS: Twenty cadavers (40 knees) were evaluated. For each cadaver, one knee was randomly assigned to KA and the other to MA. KA total knee arthroplasty (TKA) procedures were performed using a caliper-verified technique, while MA TKA procedures utilized a measured resection technique. Subsequently, all specimens were mounted on a customized knee-testing system, and patellar tracking was measured using a motion analysis system. All patellar tracking data were clustered using the density-based spatial clustering of applications with noise algorithm. Differences in patellar tracking patterns and the restoration of native patellar tracking were compared between the two alignment strategies. RESULTS: Patellar tracking patterns following KA were considerably different from MA. Pre- and post-TKA patellar tracking patterns following MA were grouped into separate clusters, whereas a substantial proportion of patellar tracking patterns following KA were grouped into the pre-TKA dominant cluster. Compared to MA, a greater proportion of patellar tracking patterns following KA showed similar patterns to native knees (p < 0.05) and more patellar tracking patterns following KA paired with preoperative patterns (p < 0.01). CONCLUSION: KA restored native patellar tracking patterns more closely compared to MA. LEVEL OF EVIDENCE: Level I, therapeutic study.

18.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 941-952, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461403

RESUMO

PURPOSE: There have been insufficient data regarding the long-term results of unrestricted kinematically aligned total knee arthroplasty (unKATKA) in Asian patients. We investigated mid- to long-term clinical and radiological follow-up data of Korean patients after caliper-verified unKATKA of minimum 7.4-10 years including categorised data of postoperative tibial component, limb and knee alignment. Additionally, we analysed the preoperative distribution and postoperative restoration of coronal plane alignment of knee (CPAK) phenotypes. METHODS: This study is a retrospective analysis of 63 patients: 96 osteoarthritic underwent consecutive caliper-verified unKATKA between October 2013 and May 2016 by a single surgeon. Implant survivorship was investigated for revision for any reason. Each knee was categorised into an in-range or outlier group by three postoperative alignment parameters: tibial component, knee and limb alignment. Statistical analyses were done for any significant differences in clinical scores and implant survival rates between groups. Finally, all knees were classified into CPAK classification postoperatively and postoperatively. The CPAK restoration rate was calculated. RESULTS: Among 85 knees in the clinically confirmed group, implant survival was 98.8%. There was one case of revision due to periprosthetic fracture. The percentage postoperatively aligned in the varus (valgus) outlier range was 100% (0%) for tibial component, 16.7% (24.8%) for the knee alignment and 51% (0%) for the limb alignment. All three categories did not affect implant survival or clinical scores. Eighty one out of 96 knees (84.4%) were restored to their CPAK phenotype postoperatively. CONCLUSION: With the limitation of a case series having a small number of patients and gender deviation, our study suggests that caliper-verified unKATKA could be a good option regardless of geographical variation of constitutional alignment in patients with osteoarthritis (OA). LEVEL OF EVIDENCE: Level IV, therapeutic study.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Tíbia/cirurgia , Fenômenos Biomecânicos
19.
Knee Surg Sports Traumatol Arthrosc ; 32(4): 915-928, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426570

RESUMO

PURPOSE: The relationship between constitutional coronal alignment and implant positioning on trochlear groove restoration in total knee arthroplasty (TKA) is poorly understood. This study aimed to determine whether the choice of alignment philosophy significantly affects the restoration of the trochlea groove. METHODS: Sixty-one imageless robotic TKAs performed by a single orthopaedic surgeon were retrospectively reviewed. In each case, the entire native trochlea was digitized to generate the native femoral anatomy, and implants were planned according to a functional alignment (FA) technique. Final implant position was recorded using the validated bone resection planes from the navigation system. Simulated femoral component positions were generated according to previously described alignment techniques: mechanical alignment (MA), gap balancing (GB), kinematic alignment (KA), restricted kinematic alignment (rKA) and restricted inverse kinematic alignment (riKA). Trochlear angle (TA), trochlear under/overstuffing and mediolateral sulcus offset were compared between the six simulated alignment techniques, as well as the final implanted technique. Further analyses investigated the effect of preoperative coronal alignment on trochlear position. Comparisons were assessed with an analysis of variance and Welch's t-tests or Wilcoxon's rank-sum tests with Bonferroni corrections. RESULTS: The implanted and simulated techniques all resulted in greater TA valgus compared to the native groove (p < 0.001). The implanted technique, KA and rKA were closer to the native TA than GB, MA and riKA (p > 0.001). All alignment philosophies understuffed the native trochlea groove. KA and rKA understuffed less than all other techniques (p < 0.001), and GB understuffed more than all other techniques (p < 0.001). In extension, all techniques shifted the trochlear sulcus laterally, while in flexion, they medialized it. These effects were most prominent in GB and MA. CONCLUSION: Personalized alignment techniques such as KA and rKA, which consider variations in individual anatomy, best restore the native patellar groove compared to systematic alignment techniques when using a standardized femoral component. LEVEL OF EVIDENCE: Level III, retrospective review.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Estudos Retrospectivos , Fêmur/cirurgia , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia
20.
Artigo em Inglês | MEDLINE | ID: mdl-38829243

RESUMO

PURPOSE: Restricted inverse kinematic alignment (iKA) is a contemporary alignment strategy for total knee arthroplasty (TKA), commonly performed with robotic assistance. While superior clinical results are reported for kinematic-type alignment strategies, registry data indicate no survivorship benefit for navigation or robotic assistance. This study aimed to determine the efficacy of an instrumented, restricted iKA technique for achieving patient-specific alignment. METHODS: Seventy-nine patients undergoing 84 TKAs (five bilateral procedures) using an iKA technique were included for preoperative and postoperative lower limb alignment analysis. The mean age was 66.5 (range: 43-82) with 33 male and 51 female patients. Artificial intelligence was employed for radiographic measurements. Alignment profiles were classified using the Coronal Plane Alignment of the Knee (CPAK) system. Preoperative and postoperative alignment profiles were compared with subanalyses for preoperative valgus, neutral and varus profiles. RESULTS: The mean joint-line convergence angle (JLCA) reduced from 2.5° to -0.1° postoperatively. The mean lateral distal femoral angle (LDFA) remained unchanged postoperatively, while the mean medial proximal tibial angle (MPTA) increased by 2.5° (p = 0.001). By preservation of the LDFA and restoration of the MPTA, the mean hip knee ankle angle (HKA) moved through 3.5° varus to 1.2° valgus. The CPAK system was used to visually depict changes in alignment profiles for preoperative valgus, neutral and varus knees; with 63% of patients observing an interval change in classification. CONCLUSION: Encouraged by the latest evidence supporting both conventional instrumentation and kinematic-type TKA strategies, this study describes how a restricted, conventionally instrumented iKA technique may be utilised to restore constitutional lower limb alignment. LEVEL OF EVIDENCE: Level III.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA