Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Materials (Basel) ; 16(9)2023 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-37176476

RESUMO

In order to study the influence of vinyl acetate-ethylene copolymerization emulsions on the bonding performance of fiber and mortar, mortar materials with different polymer contents were prepared. The optimal mix ratio of the matrix was obtained using a pull-out test with a 0° inclination angle. On this basis, polypropylene fibers and alkali-resistant glass fibers were set at different burial depths (6 mm, 12 mm, and 18 mm) and different burial angles (0°, 30°, 45°, and 60°). The load-displacement curves of two types of fibers pulled out from the polymer mortar were obtained. The test results show that polymer contents of 3% and 5% increase the peak pull-out loads of glass fibers and polypropylene fibers by 16.28% and 30.72% and 7.41% and 27.11%, respectively. When the polymer content is 7%, the peak pull-out load decreases by 1.31% and 24.26%, especially for polypropylene fiber, which significantly weakens the bonding performance between the matrix and the fiber. The pull-out load of glass fibers and polypropylene fibers increases with the increase in the buried depth, and both show tensile failure at 18 mm. As the embedding angle increases, the pull-out load of polypropylene fibers decreases continuously, while the glass fiber shows a higher pull-out load at 30°.

2.
Materials (Basel) ; 15(17)2022 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-36079404

RESUMO

Considering the random orientation and distribution of steel fibers in concrete, the synergistic reinforcement of steel fibers on concrete is much complex than the bond of single fiber. It is meaningful to study the bond behavior of steel fiber during many actions. With the inclination angle of steel fiber to pullout direction and the fiber spacing as main factors, this paper carried out fifteen groups of pullout tests for hook-end steel fiber embedded in manufactured sand mortar. The inclination angle ranged from 0 to 60°, and the fiber spacing ranged from 3.5 mm to 21.2 mm. The characteristic pullout load-slip (PL-S) curve of steel fibers are given out after treating the original complete curves of each group test. The values of key points featured the debonding, peak and residual pullout loads and slips are determined from the characteristic PL-S curves. Based on a multi-index synthetical evaluation method, the nominal debonding strength, bond strength, residual bond strength and the debonding work, slipping work, and pullout work, as well as the debonding energy ratio, slipping energy ratio, and pullout energy ratio are analyzed. Results indicate that the bond performance represented by above indexes changes with the inclination angle and spacing of steel fibers. Except for the bond mechanism performing the same as aligned steel fibers by pullout test, the bond is dominated by the resistance of mortar to peeling off near pullout surface and scraping along pullout direction. When the inclination angle is over 15° or 30°, the bond performance is generally decreased, due to the peeling off of mortar on surface of transversal section with a certain depth. When the fiber spacing is over than 5 mm, the bond performance becomes worst due to the scraping out of mortar along with the slip of steel fibers.

3.
Materials (Basel) ; 15(13)2022 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-35806789

RESUMO

To investigate the shear performance and failure mechanism of stud shear connectors in steel fiber-reinforced cementitious composite (SFRCC) beams, six steel-SFRCC and six steel-normal strength concrete (NC) push-out specimens with two heights (80 mm, 120 mm) and three diameters (14 mm, 18 mm, 22 mm) of stud connectors were prepared. The experimental results revealed that the stud shearing failure was the main failure mode of all push-out specimens. In comparison to the steel-NC specimens, the development of cracks in the SFRCC beams was efficiently restrained due to the existence of high-strength steel fibers added to the normal concrete. The shear resistance and stiffness of studs in the steel-SFRCC beams were, respectively, 22.3% and 15.1% greater than those in the steel-NC specimens; however, their ductility was reduced, and the stud shear connectors failed in advance. The finite element (FE) model was developed and verified by push-out test results. FE analysis results indicated that the shear resistance of stud shear connectors was significantly improved with the increase in the concrete compressive strength, the stud diameter and tensile strength, whereas the aspect ratio of studs had a small impact on the ultimate resistance of stud shear connectors. Based on the as-obtained push-out experiment and FE analysis results, empirical formulas were presented to predict the load-slip curves and ultimate shear resistance of stud shear connectors in the steel-SFRCC specimens, and higher accuracy and a wider application range were obtained than with previous formulas.

4.
Materials (Basel) ; 14(12)2021 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-34204313

RESUMO

Perfobond rib (PBL) shear connectors, made up of the perforated steel plates with the penetrating rebars passing through the holes, are extensively adopted in steel-concrete composite structures for their excellent performance. The adequate understanding of mechanical properties for PBL connectors is of great significance for their reasonable design. In this study, a push out experiment, including 12 specimens with the parameters of concrete strength, diameter of penetrating rebars and the number of holes on perforated steel plate, was performed to explore the mechanical behavior of PBL connectors with steel fiber high strength concrete (SFHSC). The experimental results showed that the shear capacity of the PBL connectors increased with the increase in concrete strength, diameter of the penetrating rebars and the number of holes. Furthermore, a general prediction formula for the shear capacity of PBL connectors was developed, which considers the shear contribution of concrete dowels, concrete end-bearing, interfacial bonding between the perforated steel plates and concrete and the penetrating rebars as well as the enhancement effect of steel fibers. The prediction results of the equation are in good agreement with the experimental data and could provide a reference for the design of PBL connectors.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA