Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Nanobiotechnology ; 22(1): 244, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735969

RESUMO

Biomaterials can modulate the local immune microenvironments to promote peripheral nerve regeneration. Inspired by the spatial orderly distribution and endogenous electric field of nerve fibers, we aimed to investigate the synergistic effects of electrical and topological cues on immune microenvironments of peripheral nerve regeneration. Nerve guidance conduits (NGCs) with aligned electrospun nanofibers were fabricated using a polyurethane copolymer containing a conductive aniline trimer and degradable L-lysine (PUAT). In vitro experiments showed that the aligned PUAT (A-PUAT) membranes promoted the recruitment of macrophages and induced their polarization towards the pro-healing M2 phenotype, which subsequently facilitated the migration and myelination of Schwann cells. Furthermore, NGCs fabricated from A-PUAT increased the proportion of pro-healing macrophages and improved peripheral nerve regeneration in a rat model of sciatic nerve injury. In conclusion, this study demonstrated the potential application of NGCs in peripheral nerve regeneration from an immunomodulatory perspective and revealed A-PUAT as a clinically-actionable strategy for peripheral nerve injury.


Assuntos
Macrófagos , Regeneração Nervosa , Traumatismos dos Nervos Periféricos , Poliuretanos , Ratos Sprague-Dawley , Células de Schwann , Animais , Regeneração Nervosa/efeitos dos fármacos , Poliuretanos/química , Ratos , Macrófagos/efeitos dos fármacos , Células de Schwann/efeitos dos fármacos , Nanofibras/química , Nervo Isquiático/efeitos dos fármacos , Regeneração Tecidual Guiada/métodos , Masculino , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Alicerces Teciduais/química , Camundongos , Células RAW 264.7
2.
Int J Mol Sci ; 24(18)2023 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-37762437

RESUMO

Porous structure is an important three-dimensional morphological feature of the peripheral nerve guidance conduit (NGC), which permits the infiltration of cells, nutrients, and molecular signals and the discharge of metabolic waste. Porous structures with precisely customized pore sizes, porosities, and connectivities are being used to construct fully permeable, semi-permeable, and asymmetric peripheral NGCs for the replacement of traditional nerve autografts in the treatment of long-segment peripheral nerve injury. In this review, the features of porous structures and the classification of NGCs based on these characteristics are discussed. Common methods for constructing 3D porous NGCs in current research are described, as well as the pore characteristics and the parameters used to tune the pores. The effects of the porous structure on the physical properties of NGCs, including biodegradation, mechanical performance, and permeability, were analyzed. Pore structure affects the biological behavior of Schwann cells, macrophages, fibroblasts, and vascular endothelial cells during peripheral nerve regeneration. The construction of ideal porous structures is a significant advancement in the regeneration of peripheral nerve tissue engineering materials. The purpose of this review is to generalize, summarize, and analyze methods for the preparation of porous NGCs and their biological functions in promoting peripheral nerve regeneration to guide the development of medical nerve repair materials.

3.
Int J Mol Sci ; 24(9)2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37175506

RESUMO

Cell-therapy-based nerve repair strategies hold great promise. In the field, there is an extensive amount of evidence for better regenerative outcomes when using tissue-engineered nerve grafts for bridging severe gap injuries. Although a massive number of studies have been performed using rodents, only a limited number involving nerve injury models of large animals were reported. Nerve injury models mirroring the human nerve size and injury complexity are crucial to direct the further clinical development of advanced therapeutic interventions. Thus, there is a great need for the advancement of research using large animals, which will closely reflect human nerve repair outcomes. Within this context, this review highlights various stem cell-based nerve repair strategies involving large animal models such as pigs, rabbits, dogs, and monkeys, with an emphasis on the limitations and strengths of therapeutic strategy and outcome measurements. Finally, future directions in the field of nerve repair are discussed. Thus, the present review provides valuable knowledge, as well as the current state of information and insights into nerve repair strategies using cell therapies in large animals.


Assuntos
Células-Tronco Mesenquimais , Traumatismos dos Nervos Periféricos , Doenças do Sistema Nervoso Periférico , Traumatismos do Sistema Nervoso , Humanos , Animais , Coelhos , Cães , Suínos , Engenharia Tecidual , Células de Schwann/fisiologia , Células-Tronco , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Nervo Isquiático/lesões
4.
FASEB J ; 35(11): e21896, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34634154

RESUMO

Surgical intervention with the use of autografts is considered the gold standard to treat peripheral nerve injuries. However, a biomaterial that supports and guides nerve growth would be an attractive alternative to overcome problems with limited availability, morbidity at the site of harvest, and nerve mismatches related to autografts. Native spider silk is a promising material for construction of nerve guidance conduit (NGC), as it enables regeneration of cm-long nerve injuries in sheep, but regulatory requirements for medical devices demand synthetic materials. Here, we use a recombinant spider silk protein (NT2RepCT) and a functionalized variant carrying a peptide derived from vitronectin (VN-NT2RepCT) as substrates for nerve growth support and neurite extension, using a dorsal root ganglion cell line, ND7/23. Two-dimensional coatings were benchmarked against poly-d-lysine and recombinant laminins. Both spider silk coatings performed as the control substrates with regards to proliferation, survival, and neurite growth. Furthermore, NT2RepCT and VN-NT2RepCT spun into continuous fibers in a biomimetic spinning set-up support cell survival, neurite growth, and guidance to an even larger extent than native spider silk. Thus, artificial spider silk is a promising biomaterial for development of NGCs.


Assuntos
Proliferação de Células/efeitos dos fármacos , Regeneração Nervosa/efeitos dos fármacos , Neuritos/metabolismo , Seda/farmacologia , Aranhas/metabolismo , Vitronectina/farmacologia , Animais , Autoenxertos , Materiais Biocompatíveis/farmacologia , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Gânglios Espinais/citologia , Humanos , Laminina/farmacologia , Camundongos , Neuritos/efeitos dos fármacos , Traumatismos dos Nervos Periféricos/cirurgia , Engenharia de Proteínas/métodos , Ratos , Proteínas Recombinantes/farmacologia , Seda/genética , Vitronectina/genética
5.
Int J Mol Sci ; 23(4)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35216370

RESUMO

The repair of severe nerve injuries requires an autograft or conduit to bridge the gap and avoid axon dispersion. Several conduits are used routinely, but their effectiveness is comparable to that of an autograft only for short gaps. Understanding nerve regeneration within short conduits could help improve their efficacy for longer gaps. Since Schwann cells are known to migrate on endothelial cells to colonize the "nerve bridge", the new tissue spontaneously forming to connect the injured nerve stumps, here we aimed to investigate whether this migratory mechanism drives Schwann cells to also proceed within the nerve conduits used to repair large nerve gaps. Injured median nerves of adult female rats were repaired with 10 mm chitosan conduits and the regenerated nerves within conduits were analyzed at different time points using confocal imaging of sequential thick sections. Our data showed that the endothelial cells formed a dense capillary network used by Schwann cells to migrate from the two nerve stumps into the conduit. We concluded that angiogenesis played a key role in the nerve conduits, not only by supporting cell survival but also by providing a pathway for the migration of newly formed Schwann cells.


Assuntos
Vasos Sanguíneos/fisiologia , Tecido Nervoso/fisiologia , Células de Schwann/fisiologia , Nervo Isquiático/fisiologia , Animais , Axônios/efeitos dos fármacos , Axônios/fisiologia , Vasos Sanguíneos/efeitos dos fármacos , Quitosana/farmacologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/fisiologia , Feminino , Regeneração Nervosa/efeitos dos fármacos , Regeneração Nervosa/fisiologia , Tecido Nervoso/efeitos dos fármacos , Doenças do Sistema Nervoso Periférico/fisiopatologia , Ratos , Ratos Wistar , Células de Schwann/efeitos dos fármacos , Nervo Isquiático/efeitos dos fármacos , Engenharia Tecidual/métodos
6.
Cell Tissue Res ; 383(2): 617-644, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33201351

RESUMO

Injuries to the peripheral nervous system remain a large-scale clinical problem. These injuries often lead to loss of motor and/or sensory function that significantly affects patients' quality of life. The current neurosurgical approach for peripheral nerve repair involves autologous nerve transplantation, which often leads to clinical complications. The most pressing need is to increase the regenerative capacity of existing tubular constructs in the repair of large nerve gaps through development of tissue-engineered approaches that can surpass the performance of autografts. To fully realize the clinical potential of nerve conduit technology, there is a need to reconsider design strategies, biomaterial selection, fabrication techniques and the various potential modifications to optimize a conduit microenvironment that can best mimic the natural process of regeneration. In recent years, a significant progress has been made in the designing and functionality of bioengineered nerve conduits to bridge long peripheral nerve gaps in various animal models. However, translation of this work from lab to commercial scale has not been achieve. The current review summarizes recent advances in the development of tissue engineered nerve guidance conduits (NGCs) with regard to choice of material, novel fabrication methods, surface modifications and regenerative cues such as stem cells and growth factors to improve regeneration performance. Also, the current clinical potential and future perspectives to achieve therapeutic benefits of NGCs will be discussed in context of peripheral nerve regeneration.


Assuntos
Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/fisiopatologia , Engenharia Tecidual , Alicerces Teciduais/química , Pesquisa Translacional Biomédica , Animais , Materiais Biocompatíveis/farmacologia , Humanos
7.
Artif Organs ; 45(6): 616-624, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33270261

RESUMO

Nerve growth factor (NGF) is important for peripheral nerve regeneration. However, its short half-life and rapid diffusion in body fluids limit its clinical efficacy. Collagen has favorable biocompatibility and biodegradability, and weak immunogenicity. Because it possesses an NGF binding domain, we cross-linked heparin to collagen tubes to construct nerve guidance conduits for delivering NGF. The conduits were implanted to bridge a facial nerve defect in rats. Histological and functional analyses were performed to assess the effect of the nerve guidance conduit on facial nerve regeneration. Heparin enhanced the binding of NGF to collagen while retaining its bioactivity. Also, the nerve guidance conduit significantly promoted axonal growth and Schwan cell proliferation at 12 weeks after surgery. The nerve regeneration and functional recovery outcomes using the nerve guidance conduit were similar to those of autologous nerve grafting. Therefore, the nerve guidance conduit may promote safer nerve regeneration.


Assuntos
Colágeno/farmacologia , Nervo Facial/efeitos dos fármacos , Heparina/farmacologia , Fator de Crescimento Neural/farmacologia , Regeneração Nervosa/efeitos dos fármacos , Próteses e Implantes , Animais , Proliferação de Células , Feminino , Regeneração Nervosa/fisiologia , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica
8.
Int J Mol Sci ; 22(12)2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34207389

RESUMO

Hollow nerve guidance conduits are approved for clinical use for defect lengths of up to 3 cm. This is because also in pre-clinical evaluation they are less effective in the support of nerve regeneration over critical defect lengths. Hydrogel luminal fillers are thought to improve the regeneration outcome by providing an optimized matrix inside bioartificial nerve grafts. We evaluated here a modified hyaluronic acid-laminin-hydrogel (M-HAL) as luminal filler for two clinically approved hollow nerve guides. Collagen-based and chitosan-based nerve guides were filled with M-HAL in two different concentrations and the regeneration outcome comprehensively studied in the acute repair rat sciatic nerve 15 mm critical defect size model. Autologous nerve graft (ANG) repair served as gold-standard control. At 120 days post-surgery, all ANG rats demonstrated electrodiagnostically detectable motor recovery. Both concentrations of the hydrogel luminal filler induced improved regeneration outcome over empty nerve guides. However, neither combination with collagen- nor chitosan-based nerve guides resulted in functional recovery comparable to the ANG repair. In contrast to our previous studies, we demonstrate here that M-HAL slightly improved the overall performance of either empty nerve guide type in the critical defect size model.


Assuntos
Regeneração Tecidual Guiada/métodos , Ácido Hialurônico/química , Hidrogéis/química , Laminina/química , Regeneração Nervosa , Traumatismos dos Nervos Periféricos/cirurgia , Animais , Células Cultivadas , Feminino , Ratos , Ratos Endogâmicos Lew
9.
Biomed Microdevices ; 22(4): 81, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33201329

RESUMO

Nerve guidance conduits (NGCs) composed of biocompatible polymers have been attracting attention as an alternative for autograft surgery in peripheral nerve regeneration. However, the nerve tissues repaired by NGCs often tend to be inadequate and lead to functional failure because of the lack of cellular supports. This paper presents a chitosan-collagen hydrogel conduit containing cells to induce peripheral nerve regeneration with cellular support. The conduit composed of two coaxial hydrogel layers of chitosan and collagen is simply made by molding and mechanical anchoring attachment with holes made on the hydrogel tube. A chitosan layer strengthens the conduit mechanically, and a collagen layer provides a scaffold for cells supporting the axonal extension. The conduits of different diameters (outer diameter approximately 2-4 mm) are fabricated. The conduit is bioabsorbable with lysozyme, and biocompatible even under bio absorption. In the neuron culture demonstration, the conduit containing Schwann cells induced the extension of the axon of neurons directed to the conduit. Our easily fabricated conduit could help the high-quality regeneration of peripheral nerves and contribute to the nerve repair surgery.


Assuntos
Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Quitosana/química , Colágeno/química , Hidrogéis/química , Regeneração Nervosa/efeitos dos fármacos , Nervos Periféricos/fisiologia , Cápsulas , Nervos Periféricos/citologia , Células de Schwann/citologia , Engenharia Tecidual
10.
Muscle Nerve ; 61(6): 726-739, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31883129

RESUMO

Despite advances in surgery, the reconstruction of segmental nerve injuries continues to pose challenges. In this review, current neurobiology regarding regeneration across a nerve defect is discussed in detail. Recent findings include the complex roles of nonneuronal cells in nerve defect regeneration, such as the role of the innate immune system in angiogenesis and how Schwann cells migrate within the defect. Clinically, the repair of nerve defects is still best served by using nerve autografts with the exception of small, noncritical sensory nerve defects, which can be repaired using autograft alternatives, such as processed or acellular nerve allografts. Given current clinical limits for when alternatives can be used, advanced solutions to repair nerve defects demonstrated in animals are highlighted. These highlights include alternatives designed with novel topology and materials, delivery of drugs specifically known to accelerate axon growth, and greater attention to the role of the immune system.


Assuntos
Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/cirurgia , Procedimentos de Cirurgia Plástica/tendências , Alicerces Teciduais/tendências , Transplantes/transplante , Animais , Humanos , Traumatismos dos Nervos Periféricos/fisiopatologia , Procedimentos de Cirurgia Plástica/métodos , Transplante Autólogo/métodos , Transplante Autólogo/tendências
11.
Adv Healthc Mater ; 13(20): e2400142, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38566357

RESUMO

Nerve guidance conduits (NGCs) are widely developed using various materials for the functional repair of injured or diseased peripheral nerves. Especially, hydrogels are considered highly suitable for the fabrication of NGCs due to their beneficial tissue-mimicking characteristics (e.g., high water content, softness, and porosity). However, the practical applications of hydrogel-based NGCs are hindered due to their poor mechanical properties and complicated fabrication processes. To bridge this gap, a novel double-network (DN) hydrogel using alginate and gelatin by a two-step crosslinking process involving chemical-free gamma irradiation and ionic crosslinking, is developed. DN hydrogels (1% alginate and 15% gelatin), crosslinked with 30 kGy gamma irradiation and barium ions, exhibit substantially improved mechanical properties, including tensile strength, elastic modulus, and fracture stain, compared to single network (SN) gelatin hydrogels. Additionally, the DN hydrogel NGC exhibits excellent kink resistance, mechanical stability to successive compression, suture retention, and enzymatic degradability. In vivo studies with a sciatic defect rat model indicate substantially improved nerve function recovery with the DN hydrogel NGC compared to SN gelatin and commercial silicone NGCs, as confirm footprint analysis, electromyography, and muscle weight measurement. Histological examination reveals that, in the DN NGC group, the expression of Schwann cell and neuronal markers, myelin sheath, and exon diameter are superior to the other controls. Furthermore, the DN NGC group demonstrates increased muscle fiber formation and reduced fibrotic scarring. These findings suggest that the mechanically robust, degradable, and biocompatible DN hydrogel NGC can serve as a novel platform for peripheral nerve regeneration and other biomedical applications, such as implantable tissue constructs.


Assuntos
Alginatos , Raios gama , Gelatina , Hidrogéis , Regeneração Nervosa , Ratos Sprague-Dawley , Gelatina/química , Animais , Regeneração Nervosa/efeitos dos fármacos , Regeneração Nervosa/fisiologia , Alginatos/química , Hidrogéis/química , Hidrogéis/farmacologia , Ratos , Nervo Isquiático/fisiologia , Nervo Isquiático/efeitos dos fármacos , Regeneração Tecidual Guiada/métodos , Alicerces Teciduais/química
12.
ACS Appl Bio Mater ; 7(2): 1095-1114, 2024 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-38270084

RESUMO

Peripheral nerve injury poses a threat to the mobility and sensitivity of a nerve, thereby leading to permanent function loss due to the low regenerative capacity of mature neurons. To date, the most widely clinically applied approach to bridging nerve injuries is autologous nerve grafting, which faces challenges such as donor site morbidity, donor shortages, and the necessity of a second surgery. An effective therapeutic strategy is urgently needed worldwide to overcome the current limitations. Herein, a magnetic nerve guidance conduit (NGC) based on biocompatible biodegradable poly(3-hydroxybutyrate) (PHB) and 8 wt % of magnetite nanoparticles modified by citric acid (Fe3O4-CA) was fabricated by electrospinning. The crystalline structure of NGCs was studied by X-ray diffraction, which indicated an enlarged ß-phase of PHB in the composite conduit compared to a pure PHB conduit. Tensile tests revealed greater ductility of PHB/Fe3O4-CA: the composite conduit has Young's modulus of 221 ± 52 MPa and an elongation at break of 28.6 ± 2.9%, comparable to clinical materials. Saturation magnetization (σs) of Fe3O4-CA and PHB/Fe3O4-CA is 61.88 ± 0.29 and 7.44 ± 0.07 emu/g, respectively. The water contact angle of the PHB/Fe3O4-CA conduit is lower as compared to pure PHB, while surface free energy (σ) is significantly higher, which was attributed to higher surface roughness and an amorphous phase as well as possible PHB/Fe3O4-CA interface interactions. In vitro, the conduits supported the proliferation of rat mesenchymal stem cells (rMSCs) and SH-SY5Y cells in a low-frequency magnetic field (0.67 Hz, 68 mT). In vivo, the conduits were used to bridge damaged sciatic nerves in rats; pure PHB and composite PHB/Fe3O4-CA conduits did not cause acute inflammation and performed a barrier function, which promotes nerve regeneration. Thus, these conduits are promising as implants for the regeneration of peripheral nerves.


Assuntos
Nanopartículas de Magnetita , Neuroblastoma , Traumatismos dos Nervos Periféricos , Poli-Hidroxibutiratos , Ratos , Humanos , Animais , Traumatismos dos Nervos Periféricos/terapia , Ácido 3-Hidroxibutírico/farmacologia , Materiais Biocompatíveis/farmacologia , Nanopartículas de Magnetita/uso terapêutico , Hidroxibutiratos/farmacologia , Regeneração Nervosa/fisiologia
13.
Mater Today Bio ; 25: 100950, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38318479

RESUMO

Nerve injuries pose a drastic threat to nerve mobility and sensitivity and lead to permanent dysfunction due to low regenerative capacity of mature neurons. The electrical stimuli that can be provided by electroactive materials are some of the most effective tools for the formation of soft tissues, including nerves. Electric output can provide a distinctly favorable bioelectrical microenvironment, which is especially relevant for the nervous system. Piezoelectric biomaterials have attracted attention in the field of neural tissue engineering owing to their biocompatibility and ability to generate piezoelectric surface charges. In this review, an outlook of the most recent achievements in the field of piezoelectric biomaterials is described with an emphasis on piezoelectric polymers for neural tissue engineering. First, general recommendations for the design of an optimal nerve scaffold are discussed. Then, specific mechanisms determining nerve regeneration via piezoelectric stimulation are considered. Activation of piezoelectric responses via natural body movements, ultrasound, and magnetic fillers is also examined. The use of magnetoelectric materials in combination with alternating magnetic fields is thought to be the most promising due to controllable reproducible cyclic deformations and deep tissue permeation by magnetic fields without tissue heating. In vitro and in vivo applications of nerve guidance scaffolds and conduits made of various piezopolymers are reviewed too. Finally, challenges and prospective research directions regarding piezoelectric biomaterials promoting nerve regeneration are discussed. Thus, the most relevant scientific findings and strategies in neural tissue engineering are described here, and this review may serve as a guideline both for researchers and clinicians.

14.
Mater Today Bio ; 24: 100942, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38283983

RESUMO

Nerve guidance conduits (NGCs) have been widely accepted as a promising strategy for peripheral nerve regeneration. Fabricating ideal NGCs with good biocompatibility, biodegradability, permeability, appropriate mechanical properties (space maintenance, suturing performance, etc.), and oriented topographic cues is still current research focus. From the perspective of translation, the technique stability and scalability are also an important consideration for industrial production. Recently, blow-spinning technique shows great potentials in nanofibrous scaffolds fabrication, possessing high quality, high fiber production rates, low cost, ease of maintenance, and high reliability. In this study, we proposed for the first time the preparation of a novel NGC via blow-spinning technique to obtain optimized performances and high productivity. A new collagen nanofibrous neuro-tube with the bilayered design was developed, incorporating inner oriented and outer random topographical cues. The bilayer structure enhances the mechanical properties of the conduit in dry and wet, displaying good radial support and suturing performance. The porous nature of the blow-spun collagen membrane enables good nutrient delivery and metabolism. The in vitro and in vivo evaluations indicated the bilayer-structure conduit could promoted Schwann cells growth, neurotrophic factors secretion, and axonal regeneration and motor functional recovery in rat.

15.
Biosens Bioelectron ; 263: 116578, 2024 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-39038398

RESUMO

Peripheral nerve injury (PNI) poses a significant public health issue, often leading to muscle atrophy and persistent neuropathic pain, which can drastically impact the quality of life for patients. Electrical stimulation represents an effective and non-pharmacological treatment to promote nerve regeneration. Yet, the postoperative application of electrical stimulation remains a challenge. Here, we propose a fully biodegradable, self-powered nerve guidance conduit (NGC) based on dissolvable zinc-molybdenum batteries. The conduit can offer topographic guidance for nerve regeneration and deliver sustained electrical cues between both ends of a transected nerve stump, extending beyond the surgical window. Schwann cell proliferation and adenosine triphosphate (ATP) production are enhanced by the introduction of the zinc-molybdenum batteries. In rodent models with 10-mm sciatic nerve damage, the device effectively enhances nerve regeneration and motor function recovery. This study offers innovative strategies for creating biodegradable and electroactive devices that hold important promise to optimize therapeutic outcomes for nerve regeneration.


Assuntos
Regeneração Nervosa , Traumatismos dos Nervos Periféricos , Nervo Isquiático , Zinco , Animais , Traumatismos dos Nervos Periféricos/terapia , Zinco/química , Nervo Isquiático/fisiologia , Nervo Isquiático/lesões , Ratos , Fontes de Energia Elétrica , Molibdênio/química , Células de Schwann , Ratos Sprague-Dawley , Humanos , Regeneração Tecidual Guiada/instrumentação , Regeneração Tecidual Guiada/métodos , Técnicas Biossensoriais , Implantes Absorvíveis
16.
Bioengineering (Basel) ; 11(2)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38391670

RESUMO

BACKGROUND: Peripheral nerve injuries (PNIs) represent a significant clinical problem, and standard approaches to nerve repair have limitations. Recent breakthroughs in 3D printing and stem cell technologies offer a promising solution for nerve regeneration. The main purpose of this study was to examine the biomechanical characteristics in muscle tissue distal to a nerve defect in a murine model of peripheral nerve regeneration from physiological stress to failure. METHODS: In this experimental study, we enrolled 18 Wistar rats in which we created a 10 mm sciatic nerve defect. Furthermore, we divided them into three groups as follows: in Group 1, we used 3D nerve guidance conduits (NGCs) and adipose stem cells (ASCs) in seven rats; in Group 2, we used only 3D NGCs for seven rats; and in Group 3, we created only the defect in four rats. We monitored the degree of atrophy at 4, 8, and 12 weeks by measuring the diameter of the tibialis anterior (TA) muscle. At the end of 12 weeks, we took the TA muscle and analyzed it uniaxially at 10% stretch until failure. RESULTS: In the group of animals with 3D NGCs and ASCs, we recorded the lowest degree of atrophy at 4 weeks, 8 weeks, and 12 weeks after nerve reconstruction. At 10% stretch, the control group had the highest Cauchy stress values compared to the 3D NGC group (0.164 MPa vs. 0.141 MPa, p = 0.007) and the 3D NGC + ASC group (0.164 MPa vs. 0.123 MPa, p = 0.007). In addition, we found that the control group (1.763 MPa) had the highest TA muscle stiffness, followed by the 3D NGC group (1.412 MPa), with the best muscle elasticity showing in the group in which we used 3D NGC + ASC (1.147 MPa). At failure, TA muscle samples from the 3D NGC + ASC group demonstrated better compliance and a higher degree of elasticity compared to the other two groups (p = 0.002 and p = 0.008). CONCLUSIONS: Our study demonstrates that the combination of 3D NGC and ASC increases the process of nerve regeneration and significantly improves the compliance and mechanical characteristics of muscle tissue distal to the injury site in a PNI murine model.

17.
Macromol Biosci ; 24(5): e2300453, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38224015

RESUMO

Spinal cord injuries are very common worldwide, leading to permanent nerve function loss with devastating effects in the affected patients. The challenges and inadequate results in the current clinical treatments are leading scientists to innovative neural regenerative research. Advances in nanoscience and neural tissue engineering have opened new avenues for spinal cord injury (SCI) treatment. In order for designed nerve guidance conduit (NGC) to be functionally useful, it must have ideal scaffold properties and topographic features that promote the linear orientation of damaged axons. In this study, it is aimed to develop channeled polycaprolactone (PCL)/Poly-D,L-lactic-co-glycolic acid (PLGA) hybrid film scaffolds, modify their surfaces by IKVAV pentapeptide/gold nanoparticles (AuNPs) or polypyrrole (PPy) and investigate the behavior of motor neurons on the designed scaffold surfaces in vitro under static/bioreactor conditions. Their potential to promote neural regeneration after implantation into the rat SCI by shaping the film scaffolds modified with neural factors into a tubular form is also examined. It is shown that channeled groups decorated with AuNPs highly promote neurite orientation under bioreactor conditions and also the developed optimal NGC (PCL/PLGA G1-IKVAV/BDNF/NGF-AuNP50) highly regenerates SCI. The results indicate that the designed scaffold can be an ideal candidate for spinal cord regeneration.


Assuntos
Fator Neurotrófico Derivado do Encéfalo , Ouro , Nanopartículas Metálicas , Fator de Crescimento Neural , Traumatismos da Medula Espinal , Alicerces Teciduais , Animais , Ratos , Fator Neurotrófico Derivado do Encéfalo/farmacologia , Ouro/química , Nanopartículas Metálicas/química , Fator de Crescimento Neural/farmacologia , Regeneração Nervosa/efeitos dos fármacos , Oligopeptídeos/farmacologia , Poliésteres/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Ratos Sprague-Dawley , Traumatismos da Medula Espinal/terapia , Traumatismos da Medula Espinal/patologia , Alicerces Teciduais/química
18.
Regen Biomater ; 10: rbac089, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36683739

RESUMO

A new nerve guidance conduits (NGCs) named MC@Col containing Type I collagen (Col) and mineralized collagen (MC) was developed, enhancing mechanical and degradation behavior. The physicochemical properties, the mechanical properties and in vitro degradation behavior were all evaluated. The adhesion and proliferation of Schwann cells (SCs) were observed. In the in vivo experiment, MC@Col NGC and other conduits including Col, chitosan (CST) and polycaprolactone (PCL) conduit were implanted to repair a 10-mm-long Sprague-Dawley rat's sciatic nerve defect. Histological analyses, morphological analyses, electrophysiological analyses and further gait analyses were all evaluated after implantation in 12 weeks. The strength and degradation performance of the MC@Col NGC were improved by the addition of MC in comparison with pure Col NGC. In vitro cytocompatibility evaluation revealed that the SCs had good viability, attachment and proliferation in the MC@Col. In in vivo results, the regenerative outcomes of MC@Col NGC were close to those by an autologous nerve graft in some respects, but superior to those by Col, CST and PCL conduits. The MC@Col NGC exhibited good mechanical performance as well as biocompatibility to bridge nerve gap and guide nerve regeneration, thus showing great promising potential as a new type of conduit in clinical applications.

19.
ACS Biomater Sci Eng ; 9(12): 6821-6834, 2023 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38011305

RESUMO

In recent years, conductive biomaterials have been widely used to enhance peripheral nerve regeneration. However, most biomaterials use electronic conductors to increase the conductivity of materials. As information carriers, electronic conductors always transmit discontinuous electrical signals, while biological systems essentially transmit continuous signals through ions. Herein, an ion-based conductive hydrogel was fabricated by simple copolymerization of the zwitterionic monomer sulfobetin methacrylate and hydroxyethyl methacrylate. Benefiting from the excellent mechanical stability, suitable electrical conductivity, and good cytocompatibility of the zwitterionic hydrogel, the Schwann cells cultured on the hydrogel could grow and proliferate better, and dorsal root ganglian had an increased neurite length. The zwitterionic hydrogel-based nerve guidance conduits were then implanted into a 10 mm sciatic nerve defect model in rats. Morphological analysis and electrophysiological data showed that the grafts achieved a regeneration effect close to that of the autologous nerve. Overall, our developed zwitterionic hydrogel facilitates efficient and efficacious peripheral nerve regeneration by mimicking the electrical and mechanical properties of the extracellular matrix and creating a suitable regeneration microenvironment, providing a new material reserve for the repair of peripheral nerve injury.


Assuntos
Materiais Biocompatíveis , Hidrogéis , Ratos , Animais , Hidrogéis/farmacologia , Materiais Biocompatíveis/farmacologia , Nervo Isquiático/fisiologia , Alicerces Teciduais , Regeneração Nervosa/fisiologia
20.
Macromol Biosci ; 23(10): e2300025, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37282815

RESUMO

O-carboxymethyl chitosan (CM-chitosan), holds high potential as a valuable biomaterial for nerve guidance conduits (NGCs). However, the lack of explicit bioactivity on neurocytes and poor duration that does not match nerve repair limit the restorative effects. Herein, CM-chitosan-based NGC is designed to induce the reconstruction of damaged peripheral nerves without addition of other activation factors. CM-chitosan possesses excellent performance in vitro for nerve tissue engineering, such as increasing the organization of filamentous actin and the expression of phospho-Akt, and facilitating the cell cycle and migration of Schwann cells. Moreover, CM-chitosan exhibits increased longevity upon cross-linking (C-CM-chitosan) with 1, 4-Butanediol diglycidyl ether, and C-CM-chitosan fibers possess appropriate biocompatibility. In order to imitate the structure of peripheral nerves, multichannel bioactive NGCs are prepared from lumen fillers of oriented C-CM-chitosan fibers and outer warp-knitted chitosan pipeline. Implantation of the C-CM-chitosan NGCs to rats with 10-mm defects of peripheral nerves effectively improve nerve function reconstruction by increasing the sciatic functional index, decreasing the latent periods of heat tingling, enhancing the gastrocnemius muscle, and promoting nerve axon recovery, showing regenerative efficacy similar to that of autograft. The results lay a theoretical foundation for improving the potential high-value applications of CM-chitosan-based bioactive materials in nerve tissue engineering.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA