1.
Ultrason Imaging ; 40(1): 35-48, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28691586

RESUMO

Conventional two-dimensional (2D) ultrasound imaging is a powerful diagnostic tool in the hands of an experienced user, yet 2D ultrasound remains clinically underutilized and inherently incomplete, with output being very operator dependent. Volumetric ultrasound systems can more fully capture a three-dimensional (3D) region of interest, but current 3D systems require specialized transducers, are prohibitively expensive for many clinical departments, and do not register image orientation with respect to the patient; these systems are designed to provide improved workflow rather than operator independence. This work investigates whether it is possible to add volumetric 3D imaging capability to existing 2D ultrasound systems at minimal cost, providing a practical means of reducing operator dependence in ultrasound. In this paper, we present a low-cost method to make 2D ultrasound systems capable of quality volumetric image acquisition: we present the general system design and image acquisition method, including the use of a probe-mounted orientation sensor, a simple probe fixture prototype, and an offline volume reconstruction technique. We demonstrate initial results of the method, implemented using a Verasonics Vantage research scanner.


Assuntos
Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Humanos , Imageamento Tridimensional/economia , Transdutores/economia , Ultrassonografia/economia
2.
J Matern Fetal Neonatal Med ; 34(11): 1805-1813, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31352874

RESUMO

RATIONALE AND OBJECTIVES: Two-dimensional (2D) ultrasound (US) is operator dependent, requiring operator skill and experience to selectively identify and record planes of interest for subsequent interpretation. This limits the utility of US in settings in which expert sonographers are unavailable. Three-dimensional (3D) US acquisition of an anatomic target, which enables reconstruction of any plane through the acquired volume, might reduce operator dependence by providing any desired image plane for interpretation, without identification of target planes of interest at the time of acquisition. We applied a low-cost 3DUS technology because of the wider potential application compared with dedicated 3DUS systems. We chose second trimester fetal biometric parameters for study because of their importance in maternal-fetal health globally. We hypothesized that expert and novice interpretations of novice-acquired 3D volumes would not differ from each other nor from expert measurements of expert-acquired 2D images, the clinical reference standard. MATERIALS AND METHODS: This was a prospective, blinded, observational study. Expert sonographers blinded to 3DUS volumes acquired 2DUS images of second trimester fetuses from 32 subjects, and expert readers performed interpretation, during usual care. A novice sonographer blinded to other clinical data acquired oriented 3DUS image volumes of the same subjects on the same date. Expert readers blinded to other data assessed placental location (PL), fetal presentation (FP), and amniotic fluid volume (AFV) in novice-acquired 3D volumes. Novice and expert raters blinded to other data independently measured biparietal diameter (BPD), humerus length (HL), and femur length (FL) for each fetus from novice-acquired 3D volumes. Corresponding gestational age (GA) estimates were calculated. Inter-rater reliability of measurements and GAs (expert 3D versus expert 2D, novice 3D versus expert 2D, and expert 3D versus novice 3D) were assessed by intraclass correlation coefficient (ICC). Mean inter-rater measurement differences were analyzed using one-way ANOVA. RESULTS: 3D volume acquisition and reconstruction required mean 30.4 s (±5.7) and 70.0 s (±24.0), respectively. PL, FP, and AFV were evaluated from volumes for all subjects; mean time for evaluation was 16 s (±0.0). PL, FP, and AFV could be evaluated for all subjects. At least one biometric measurement was possible for 31 subjects (97%). Agreement between rater pairs for a composite of all measures was excellent (ICCs ≥ 0.95), and for individual measures was good to excellent (ICCs ≥ 0.75). Inter-rater differences were not significant (p > .05). CONCLUSIONS: Expert and novice interpretations of novice-acquired 3DUS volumes of second trimester fetuses provided reliable biometric measures compared with expert interpretation of expert-acquired 2DUS images. 3DUS volume acquisition with a low-cost system may reduce operator dependence of ultrasound.


Assuntos
Imageamento Tridimensional , Ultrassonografia Pré-Natal , Feminino , Idade Gestacional , Humanos , Placenta/diagnóstico por imagem , Gravidez , Segundo Trimestre da Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA