Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Formos Med Assoc ; 122(8): 714-722, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36496300

RESUMO

BACKGROUND: Patients recovering from COVID-19 may need vaccination against SARS-CoV-2 because acquired immunity from primary infection may wane, given the emergence of new SARS-CoV-2 variants. Understanding the trends of anti-spike IgG and neutralizing antibody titers in patients recovering from COVID-19 may inform the decision made on the appropriate interval between recovery and vaccination. METHODS: Participants aged 20 years or older and diagnosed with COVID-19 between January and December, 2020 were enrolled. Serum specimens were collected every three months from 10 days to 12 months after the onset of symptom for determinations of anti-spike IgG and neutralizing antibody titers against SARS-CoV-2 Wuhan strain with D614G mutation, alpha, gamma and delta variants. RESULTS: Of 19 participants, we found a decreasing trend of geometric mean titers of anti-spike IgG from 560.9 to 217 and 92 BAU/mL after a 4-month and a 7-month follow-up, respectively. The anti-spike IgG titers declined more quickly in the ten participants with severe or critical disease than the nine participants with only mild to moderate disease between one month and seven months after SARS-CoV-2 infection (-8.49 vs - 2.34-fold, p < 0.001). The neutralizing activity of the convalescent serum specimens collected from participants recovering from wild-type SARS-CoV-2 infection against different variants was lower, especially against the delta variants (p < 0.01 for each variant with Wuhan strain as reference). CONCLUSION: Acquired immunity from primary infection with SARS-CoV-2 waned within 4-7 months in COVID-19 patients, and neutralizing cross-activities against different SARS-CoV-2 variants were lower compared with those against wild-type strain.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Anticorpos Neutralizantes , Soroterapia para COVID-19 , Imunoglobulina G , Anticorpos Antivirais
2.
BMC Infect Dis ; 22(1): 157, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-35168557

RESUMO

OBJECTIVE: Reliable high-throughput serological assays for SARS-CoV-2 antibodies present an important role in the strength and duration of immunity after vaccination. The study investigated the analytical and clinical performances of neutralizing antibodies (NTAb) assay by chemiluminescent (CLIA), and SARS-CoV-2 neutralizing antibody after vaccination in real world. METHODS: The analytical performances of CLIA for SARS-CoV-2 NTAb were evaluated, followed by the sensitivity and specificity identified with a PRNT test from 50 volunteers. Then, a cohort of vaccine recipients (n = 37) were tracked with SARS-CoV-2 NTAb assay at prior to vaccination, one, three and six months post two doses. In real world, a total of 737 cases were recruited from physical examination center in Shenzhen Luohu People's Hospital (from Jun to August 2021) to analyze vaccination status. RESULTS: Serological assays on the CLIA were found with excellent characteristics including imprecision, repeatability and linearity. Besides, it was robust to icterus, lipemia and hemolysis. The good sensitivity and specificity were obtained at 98% and 100%, respectively. NTAb results showed a high correlation with PRNT50 titers (r 0.61). Until July 2021, the BBIBP-CorV (76.3%) and Sinovac CoronaVac (20.5%) were the predominant vaccines injection in Shenzhen, China. Adolescent less than 18 years was the main unvaccinated group (52.1%). The seropositive rate of inactive SRAR-CoV-2 vaccines exceeded 97% after inoculation. The NTAb generated by Sinovac CoronaVac with the schedule of 0-56 days was found significantly lower than that by BBIBP-CorV (P < 0.001). The follow-up of NTAb changes in a cohort and the dynamic variation of NTAb in real world disclosed steep downward by almost three times for NTAb level occurred at three months post twice vaccinations. The seropositive ratio was at least 50% over 6 months. CONCLUSIONS: SARS-CoV-2 neutralizing antibodies assay show excellent analytical and clinical performances, and a high correlation with neutralizing activity. Anti-epidemic measures and the urgent trial of SARS-CoV-2 vaccine was calling for adolescents.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Adolescente , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Luminescência , SARS-CoV-2 , Vacinação
3.
Int J Mol Sci ; 23(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36076960

RESUMO

Serological assays are useful in investigating the development of humoral immunity against SARS-CoV-2 in the context of epidemiological studies focusing on the spread of protective immunity. The plaque reduction neutralization test (PRNT) is the gold standard method to assess the titer of protective antibodies in serum samples. However, to provide a result, the PRNT requires several days, skilled operators, and biosafety level 3 laboratories. Therefore, alternative methods are being assessed to establish a relationship between their outcomes and PRNT results. In this work, four different immunoassays (Roche Elecsys® Anti SARS-CoV-2 S, Snibe MAGLUMI® SARS-CoV-2 S-RBD IgG, Snibe MAGLUMI® 2019-nCoV IgG, and EUROIMMUN® SARS-CoV-2 NeutraLISA assays, respectively) have been performed on individuals healed after SARS-CoV-2 infection. The correlation between each assay and the reference method has been explored through linear regression modeling, as well as through the calculation of Pearson's and Spearman's coefficients. Furthermore, the ability of serological tests to discriminate samples with high titers of neutralizing antibodies (>160) has been assessed by ROC curve analyses, Cohen's Kappa coefficient, and positive predictive agreement. The EUROIMMUN® NeutraLISA assay displayed the best correlation with PRNT results (Pearson and Spearman coefficients equal to 0.660 and 0.784, respectively), as well as the ROC curve with the highest accuracy, sensitivity, and specificity (0.857, 0.889, and 0.829, respectively).


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Imunoglobulina G , Sensibilidade e Especificidade , Testes Sorológicos/métodos
4.
Clin Microbiol Rev ; 33(4)2020 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-32792417

RESUMO

Convalescent plasma (CP) therapy has been used since the early 1900s to treat emerging infectious diseases; its efficacy was later associated with the evidence that polyclonal neutralizing antibodies can reduce the duration of viremia. Recent large outbreaks of viral diseases for which effective antivirals or vaccines are still lacking has renewed the interest in CP as a life-saving treatment. The ongoing COVID-19 pandemic has led to the scaling up of CP therapy to unprecedented levels. Compared with historical usage, pathogen reduction technologies have now added an extra layer of safety to the use of CP, and new manufacturing approaches are being explored. This review summarizes historical settings of application, with a focus on betacoronaviruses, and surveys current approaches for donor selection and CP collection, pooling technologies, pathogen inactivation systems, and banking of CP. We additionally list the ongoing registered clinical trials for CP throughout the world and discuss the trial results published thus far.


Assuntos
Infecções por Coronavirus/terapia , Pneumonia Viral/terapia , Anticorpos Neutralizantes/análise , Bancos de Espécimes Biológicos/normas , COVID-19 , Seleção do Doador/métodos , Seleção do Doador/normas , Ensaio de Imunoadsorção Enzimática , Humanos , Imunização Passiva/efeitos adversos , Imunização Passiva/normas , Testes de Neutralização/normas , Pandemias , Síndrome Respiratória Aguda Grave/terapia , Soroterapia para COVID-19
5.
J Clin Microbiol ; 59(8): e0031921, 2021 07 19.
Artigo em Inglês | MEDLINE | ID: mdl-33962959

RESUMO

For the control of immunity in COVID-19 survivors and vaccinated subjects, there is an urgent need for reliable and rapid serological assays. Based on samples from 63 COVID-19 survivors up to 7 months after symptom onset, and on 50 serum samples taken before the beginning of the pandemic, we compared the performances of three commercial immunoassays for the detection of SARS-CoV-2 IgA and IgG antibodies (Euroimmun SARS-COV-2 IgA/IgG, Mikrogen recomWell SARS-CoV-2 IgA/IgG, and Serion ELISA agile SARS-CoV-2 IgA/IgG) and three rapid lateral flow (immunochromatographic) tests (Abbott PanBio COVID-19 IgG/IgM, Nadal COVID-19 IgG/IgM, and Cleartest Corona 2019-nCOV IgG/IgM) with a 50% plaque-reduction neutralization test (PRNT50) representing the gold standard. Fifty-seven out of 63 PCR-confirmed COVID-19 patients (90%) showed neutralizing antibodies. The sensitivity of the seven assays ranged from 7.0% to 98.3%, and the specificity ranged from 86.0% to 100.0%. Only one commercial immunoassay showed a sensitivity and specificity of greater than 98%.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Humanos , Imunoensaio , Imunoglobulina M , Pandemias , Sensibilidade e Especificidade
6.
Clin Chem Lab Med ; 59(8): 1444-1452, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33855843

RESUMO

OBJECTIVES: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT50) Ab titers. METHODS: A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. RESULTS: Assay imprecision ranged from 3.98 to 12.18% being satisfactory at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0 and 92.5%, respectively. A total of 281 leftover samples results of the PRNT50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT50 titer at univariate (ρ=0.689) and multivariate (ρ=0.712) analyses. CONCLUSIONS: SARS-CoV-2 S-RBD IgG assay shows satisfactory analytical and clinical performances, and a strong correlation with sera neutralizing activity.


Assuntos
Anticorpos Neutralizantes/imunologia , Imunoglobulina G/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/patologia , COVID-19/virologia , Criança , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Subunidades Proteicas/imunologia , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença , Adulto Jovem
7.
Biologicals ; 74: 1-9, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34716091

RESUMO

There is an increasing demand for monoclonal antibody (mAb) therapies to confer passive immunity against viral diseases. Respiratory syncytial virus (RSV) is the most common cause of bronchiolitis, lower respiratory tract infections, and hospitalization in infants. Currently, there is no RSV vaccine but a humanized mAb available for high risk infants. MK-1654 is a fully human mAb with YTE mutation in the fragment crystallizable (Fc) region to extend the half-life in circulation. It binds to a highly conserved epitope of RSV Fusion protein with high affinity and neutralizes RSV infection. A functional cell-based assay is a regulatory requirement for clinical development, commercial release, and stability testing of MK-1654. In this study, we have evaluated three RSV neutralization assays to test the potency of MK-1654, including an imaging-based virus reduction neutralization test (VRNT) and two reporter virus-based assays (RSV-GFP and RSV-NLucP). All three methods showed good dose response curves of MK-1654 with similar EC50 values. RSV-NLucP method was chosen for further development because it is simple and can be easily adapted to quality control testing laboratories. After optimization, the RSV-NLucP assay was pre-qualified with good linearity, relative accuracy, intermediate precision, and specificity, therefore suitable for a cell-based potency assay.


Assuntos
Anticorpos Monoclonais , Anticorpos Antivirais , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Anticorpos Monoclonais/farmacologia , Anticorpos Neutralizantes/farmacologia , Anticorpos Antivirais/farmacologia , Humanos , Testes de Neutralização , Infecções por Vírus Respiratório Sincicial/tratamento farmacológico , Proteínas Virais de Fusão/imunologia
8.
Indian J Med Res ; 153(5&6): 658-664, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-34145085

RESUMO

Background & objectives: Coronavirus disease 2019 (COVID-19) caused by severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) continues to be a devastating pandemic. This study was aimed at performance assessment of SARS-CoV-2 IgM and IgG ELISAs, and investigation of their utility for patient diagnosis and sero-epidemiologic investigations. Methods: Serum/plasma samples from COVID-19 patients or asymptomatic contacts (n=180) and healthy donors (n=90) were tested in parallel using two commercial IgM ELISAs (Erbalisa and Inbios), and four IgG ELISAs (Kavach, Euroimmun, Erbalisa and Inbios) along with an indigenous ß-propiolactone inactivated virus-based ELISA (IRSHA-IgG-ELISA). Plaque reduction neutralization test (PRNT) was used as reference test. Results: Among 180 COVID-19 patients, 125 tested positive by PRNT. Inbios-IgM-ELISA showed sensitivity (Se)/specificity (Sp)/positive predictive value (PPV)/negative predictive value (NPV) of 93.6/97.8/98.4/94.4 per cent in relation to PRNT, and performed better than Erbalisa-IgM-ELISA (Se: 48%, Sp: 95.6%, PPV: 95.2%, NPV: 65.2%). During the first week of disease, only 47.4 per cent of the COVID-19 patients tested IgM positive by Inbios-IgM-ELISA, detection improving at two weeks and beyond (~86-100%). Among IgG tests, Inbios-IgG-ELISA ranked first in terms of sensitivity (83.2%), followed by IRSHA (64.8%), Euroimmun (64%), Erbalisa (57.6%) and Kavach (56%) tests. For all IgG tests, sensitivity improved during the third (73.9-95.7%) and fourth week (100%) of illness. The specificity (96.7-100%) and PPV (96.2-100%) of all IgG tests were high; NPV ranged between 71.9 and 87.1 per cent with Inbios-IgG-ELISA scoring highest. Interpretation & conclusions: Our results show that IgM detection by the current, most sensitive ELISAs cannot replace molecular diagnosis, but may aid as a supplement test. The available IgG tests are suitable for serosurveys for the assessment of previous virus exposure.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , Ensaio de Imunoadsorção Enzimática , Humanos , Imunoglobulina G , Imunoglobulina M , Testes de Neutralização , Sensibilidade e Especificidade
9.
J Infect Dis ; 220(9): 1462-1468, 2019 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-31299077

RESUMO

BACKGROUND: The plaque reduction neutralization test (PRNT), which measures a subset of immunoglobulin antibodies (functional neutralizing antibodies), and the enzyme-linked immunosorbent assay (ELISA), which measures total immunoglobulin (neutralizing and nonneutralizing antibodies), characterize different aspects of the anti-mumps virus antibody response after vaccination. METHODS: Data from a recent phase 3 clinical trial (NCT01681992) of 2 measles-mumps-rubella vaccines were used to compare anti-mumps antibody responses measured using an unenhanced PRNT (GSK; seropositivity cutoff and threshold, 2.5 and 4 times the 50% end-point dilution, respectively) with those estimated using an ELISA (thresholds, 5 and 10 ELISA units/mL, respectively). RESULTS: Of 3990 initially seronegative samples, 3284 (82.3%) were seropositive after vaccination for anti-mumps antibodies in both assays. The Pearson correlation coefficient for double-positive samples was 0.57, indicative of a moderate correlation. Receiver operating characteristic curve analysis showed that an ELISA threshold of 51.7 ELISA units/mL best corresponded to the PRNT seroresponse threshold. There was no obvious vaccine brand effect on the correlation between assays. CONCLUSIONS: The moderate correlation between the anti-mumps antibody measurements obtained with PRNT and ELISA reflects different aspects of the serological response. In the absence of a well-defined protective serological threshold, PRNT provides complementary information on the antibody response, whereas ELISA remains a critically useful measurement of vaccine immunogenicity.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Ensaio de Imunoadsorção Enzimática/métodos , Vacina contra Sarampo-Caxumba-Rubéola/administração & dosagem , Vírus da Caxumba/imunologia , Testes de Neutralização/métodos , Ensaios Clínicos Fase III como Assunto , Feminino , Humanos , Lactente , Masculino , Curva ROC , Ensaio de Placa Viral/métodos
10.
Emerg Infect Dis ; 25(9): 1752-1753, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31441752

RESUMO

Since its recent discovery, Bourbon virus has been isolated from a human and ticks. To assess exposure of potential vertebrate reservoirs, we assayed banked serum and plasma samples from wildlife and domestic animals in Missouri, USA, for Bourbon virus-neutralizing antibodies. We detected high seroprevalence in raccoons (50%) and white-tailed deer (86%).


Assuntos
Reservatórios de Doenças , Thogotovirus/isolamento & purificação , Animais , Animais Domésticos/virologia , Animais Selvagens/virologia , Missouri
11.
Emerg Infect Dis ; 25(2): 374-376, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30666941

RESUMO

We tested a sample of 234 wild long-tailed macaques (Macaca fascicularis) trapped in Peninsular Malaysia in 2009, 2010, and 2016 for Zika virus RNA and antibodies. None were positive for RNA, and only 1.3% were seropositive for neutralizing antibodies. Long-tailed macaques are unlikely to be reservoirs for Zika virus in Malaysia.


Assuntos
Doenças dos Macacos/epidemiologia , Doenças dos Macacos/virologia , Infecção por Zika virus/veterinária , Zika virus , Animais , Animais Selvagens , Macaca fascicularis , Malásia/epidemiologia , RNA Viral , Sorogrupo , Zika virus/classificação , Zika virus/genética
12.
Virol J ; 16(1): 125, 2019 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-31665014

RESUMO

BACKGROUND: Dengue is an important mosquito-borne disease. There is currently only one licensed vaccine for dengue prevention. The vaccine provides higher efficacy in pre-vaccination dengue-seropositive persons but a higher risk of subsequent more severe dengue in dengue-seronegative persons. It is recommended that the dengue vaccine may be given in dengue-seropositive individuals or as mass vaccination without individual pre-vaccination screening in areas where the dengue seroprevalence is > 80% in children aged 9 years. We evaluated a dengue specific immunoglobulin G monoclonal antibody-based capture enzyme-linked immunosorbent assay (MAb-ELISA) in the diagnosis of previous dengue infection using serum samples from the cohort study in Ratchaburi Province, Thailand. METHODS: The MAb-ELISA was compared to 70% plaque reduction neutralization test (PRNT70) in 453 serum samples from children aged 3-11 years in Ratchaburi Province, Thailand. RESULTS: The sensitivity and specificity of MAb-ELISA at the positive to negative (P/N) ratio cut-off level of > 3 were both 0.91 in the diagnosis of previous dengue infection, compared to PRNT70. The false positivity was mainly in Japanese encephalitis (JE) seropositive subjects. CONCLUSIONS: This research provides evidence that MAb-ELISA is useful for dengue seroprevalence study and dengue pre-vaccination screening. JE seropositivity was the major cause of false positive result in the study population.


Assuntos
Vírus da Dengue/isolamento & purificação , Dengue/diagnóstico , Ensaio de Imunoadsorção Enzimática/normas , Técnicas Microbiológicas/métodos , Anticorpos Monoclonais/imunologia , Anticorpos Antivirais/sangue , Criança , Pré-Escolar , Estudos de Coortes , Dengue/sangue , Dengue/epidemiologia , Vírus da Dengue/imunologia , Humanos , Imunoglobulina M/sangue , Técnicas Microbiológicas/normas , Testes de Neutralização , Sensibilidade e Especificidade , Estudos Soroepidemiológicos , Tailândia/epidemiologia
13.
Virol J ; 16(1): 65, 2019 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-31101058

RESUMO

BACKGROUND: Yellow fever, Dengue, West Nile and Zika viruses are re-emerging mosquito-borne Flaviviruses of public health concern. However, the extent of human exposure to these viruses and associated disease burden in Kenya and Africa at large remains unknown. We assessed the seroprevalence of Yellow fever and other Flaviviruses in human populations in West Pokot and Turkana Counties of Kenya. These areas border Uganda, South Sudan and Ethiopia where recent outbreaks of Yellow fever and Dengue have been reported, with possibility of spillover to Kenya. METHODOLOGY: Human serum samples collected through a cross-sectional survey in West Pokot and Turkana Counties were screened for neutralizing antibodies to Yellow fever, Dengue-2, West Nile and Zika virus using the Plaque Reduction Neutralization Test (PRNT). Seroprevalence was compared by county, site and important human demographic characteristics. Adjusted odds ratios (aOR) were estimated using Firth logistic regression model. RESULTS: Of 877 samples tested, 127 neutralized with at least one of the four flaviviruses (14.5, 95% CI 12.3-17.0%), with a higher proportion in Turkana (21.1%, n = 87/413) than in West Pokot (8.6%, n = 40/464). Zika virus seroprevalence was significantly higher in West Pokot (7.11%) than in Turkana County (0.24%; χ2 P < 0.0001). A significantly higher Yellow fever virus seroprevalence was also observed in Turkana (10.7%) compared to West Pokot (1.29%; χ2 P < 0.0001). A high prevalence of West Nile virus was detected in Turkana County only (10.2%) while Dengue was only detected in one sample, from West Pokot. The odds of infection with West Nile virus was significantly higher in males than in females (aOR = 2.55, 95% CI 1.22-5.34). Similarly, the risk of Zika virus infection in West Pokot was twice higher in males than females (aOR = 2.01, 95% CI 0.91-4.41). CONCLUSION: Evidence of neutralizing antibodies to West Nile and Zika viruses indicates that they have been circulating undetected in human populations in these areas. While the observed Yellow Fever prevalence in Turkana and West Pokot Counties may imply virus activity, we speculate that this could also be as a result of vaccination following the Yellow Fever outbreak in the Omo river valley, South Sudan and Uganda across the border.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Infecções por Flavivirus/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Criança , Estudos Transversais , Culicidae/virologia , Dengue/epidemiologia , Dengue/imunologia , Feminino , Flavivirus , Infecções por Flavivirus/imunologia , Humanos , Quênia/epidemiologia , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Fatores de Risco , Estudos Soroepidemiológicos , Febre do Nilo Ocidental/epidemiologia , Febre do Nilo Ocidental/imunologia , Adulto Jovem , Infecção por Zika virus/epidemiologia , Infecção por Zika virus/imunologia
14.
Indian J Med Res ; 149(5): 656-661, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31417034

RESUMO

Background & objectives: West Nile virus (WNV) is a neurotropic flavivirus that has emerged globally as a significant cause of viral encephalitis. The early confirmatory diagnosis of WNV infections is important for timely clinical management and in areas where multiple flaviviruses are endemic. Diagnosis of WNV infection is primarily based on serodiagnosis, followed by virus isolation and identification. The aim of this study was to develop and evaluate a highly sensitive and specific immunoglobulin M (IgM) ELISA using the recombinant CprM protein (rWNV-CprM) for rapid, early and accurate diagnosis of WNV. Methods: The gene coding for the CprM protein of WNV was cloned and expressed in pET 28a vector followed by purification. An indirect IgM microplate ELISA using purified rWNV-CprM protein was optimized having no cross-reactivity with healthy human serum and serum samples obtained from patients with dengue and Japanese encephalitis viruses infection. Results: The comparative evaluation of this rWNV-CprM protein-specific IgM ELISA with plaque reduction neutralization test using 105 blood samples collected from patients suspected to have acute WNV infection revealed 98 per cent concordance with sensitivity and specificity of 100 and 97 per cent, respectively. Interpretation & conclusions: The recombinant CprM protein-based WNV-specific ELISA reported in this study may be useful for rapid screening of large numbers of blood samples in endemic areas during outbreaks.


Assuntos
Proteínas Recombinantes/isolamento & purificação , Proteínas do Envelope Viral/sangue , Febre do Nilo Ocidental/sangue , Vírus do Nilo Ocidental/isolamento & purificação , Formação de Anticorpos/imunologia , Proteínas do Capsídeo/sangue , Proteínas do Capsídeo/isolamento & purificação , Clonagem Molecular , Ensaio de Imunoadsorção Enzimática , Humanos , Proteínas Recombinantes/sangue , Proteínas Recombinantes/imunologia , Testes Sorológicos , Proteínas do Envelope Viral/isolamento & purificação , Febre do Nilo Ocidental/imunologia , Febre do Nilo Ocidental/virologia , Vírus do Nilo Ocidental/imunologia , Vírus do Nilo Ocidental/patogenicidade
15.
J Gen Virol ; 99(9): 1248-1252, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29975185

RESUMO

Zika virus (ZIKV), transmitted by Aedes species mosquitoes, was first isolated in Uganda in 1947. From February 2014 to October 2017, the Uganda Virus Research Institute, in collaboration with the US Centers for Diseases Control and Prevention, conducted arbovirus surveillance in acute febrile illness (AFI) patients at St Francis hospital in Nkonkonjeru. Three hundred and eighty-four serum samples were collected and tested for IgM antibodies to yellow fever virus (YFV), West Nile virus (WNV), dengue virus (DENV), chikungunya virus (CHIKV) and ZIKV. Of the 384 samples, 5 were positive for ZIKV IgM. Of these five, three were confirmed by plaque reduction neutralization test (PRNT) to be ZIKV infections. Of the remaining two, one was determined to be a non-specific flavivirus infection and one was confirmed to be alphavirus-positive by reverse transcriptase polymerase chain reaction (RT-PCR). This study provides the first evidence of laboratory-confirmed ZIKV infection in Uganda in five decades, and emphasizes the need to enhance sentinel surveillance.


Assuntos
Hospitais , Vigilância de Evento Sentinela , Infecção por Zika virus/epidemiologia , Zika virus/isolamento & purificação , Humanos , Uganda/epidemiologia
16.
J Med Virol ; 90(10): 1666-1668, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29797606

RESUMO

A collection of 3069 human sera collected in the area of the municipality of Modena, Emilia Romagna, Italy, was retrospectively investigated for specific antibodies against Usutu (USUV) and West Nile viruses (WNV). All the samples resulting positive using a preliminary screening test were analyzed with the plaque reduction neutralization test. Overall, 24 sera were confirmed as positive for USUV (0.78%) and 13 for WNV (0.42%). The results suggest that in 2012, USUV was circulating more than WNV in North-eastern Italy.


Assuntos
Anticorpos Antivirais/sangue , Flavivirus/imunologia , Vírus do Nilo Ocidental/imunologia , Anticorpos Neutralizantes/sangue , Doadores de Sangue , Humanos , Itália/epidemiologia , Testes de Neutralização , Estudos Retrospectivos , Estudos Soroepidemiológicos
17.
Virol J ; 14(1): 133, 2017 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-28720142

RESUMO

BACKGROUND: Hantaan and Seoul viruses, in the Hantavirus genus, are known to cause hemorrhagic fever with renal syndrome (HFRS). The plaque reduction neutralization test (PRNT), as conventional neutralization test for hantaviruses, is laborious and time-consuming. Alternatives to PRNT for hantaviruses are required. METHODS: In this study, the methods for Hantaan and Seoul viruses serological typing including microneutralization test (MNT), pseudoparticle neutralization test (PPNT) and immunofluorescence assay based on viral glycoproteins (IFA-GP) were developed and compared with PRNT using a panel of 74 sera including 44 convalescent sera of laboratory confirmed HFRS patients and 30 patients sera of non-hantavirus infection. Antibody titres and serotyping obtained with different methods above were analyzed by paired-t, linear correlation, McNemar χ2 and Kappa agreement tests. RESULTS: Antibody titres obtained with MNT50, PPNT50 and IFA-GP were significantly correlated with that obtained with PRNT50 (p < 0.001). GMT determined by PPNT50 was statistically higher than that determined by PRNT50 (p < 0.001), while GMT determined by MNT50 and IFA-GP were equal with (p > 0.05) and less than (p < 0.001) that obtained with PRNT50 respectively. Serotyping obtained with MNT50 and PRNT50, PPNT50 and PRNT50 were highly consistent (p < 0.001), whereas that obtained with IFA-GP and PRNT50 were moderately consistent (p < 0.001). There were no significant differences for serotyping between PRNT50 and MNT50, as well as PRNT50 and PPNT50 (p > 0.05). IFA-GP was less sensitive than PRNT50 and MNT50 for serotyping of hantaviruses infection (p < 0.05). However, for 79.5% (35/44) samples, serotyping determined by IFA-GP and PRNT50 were consistent. CONCLUSIONS: MNT50 and PPNT50 both can be used as simple and rapid alternatives to PRNT50, and MNT50 is more specific while PPNT50 is more sensitive than other assays for neutralizing antibody determination. So far, this work has been the most comprehensive comparison of alternatives to PRNT.


Assuntos
Anticorpos Antivirais/sangue , Vírus Hantaan/imunologia , Vírus Seoul/imunologia , Sorotipagem/métodos , Humanos , Sensibilidade e Especificidade
18.
Am J Obstet Gynecol ; 216(3): 209-225, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28126366

RESUMO

Zika virus is an emerging mosquito-borne (Aedes genus) arbovirus of the Flaviviridae family. Following epidemics in Micronesia and French Polynesia during the past decade, more recent Zika virus infection outbreaks were first reported in South America as early as May 2013 and spread to now 50 countries throughout the Americas. Although no other flavivirus has previously been known to cause major fetal malformations following perinatal infection, reports of a causal link between Zika virus and microcephaly, brain and ocular malformations, and fetal loss emerged from hard-hit regions of Brazil by October 2015. Among the minority of infected women with symptoms, clinical manifestations of Zika virus infection may include fever, headache, arthralgia, myalgia, and maculopapular rash; however, only 1 of every 4-5 people who are infected have any symptoms. Thus, clinical symptom reporting is an ineffective screening tool for the relative risk assessment of Zika virus infection in the majority of patients. As previously occurred with other largely asymptomatic viral infections posing perinatal transmission risk (such as HIV or cytomegalovirus), we must develop and implement rapid, sensitive, and specific screening and diagnostic testing for both viral detection and estimation of timing of exposure. Unfortunately, despite an unprecedented surge in attempts to rapidly advance perinatal clinical testing for a previously obscure arbovirus, there are several ongoing hindrances to molecular- and sonographic-based screening and diagnosis of congenital Zika virus infection. These include the following: (1) difficulty in estimating the timing of exposure for women living in endemic areas and thus limited interpretability of immunoglobulin M serologies; (2) cross-reaction of immunoglobulin serologies with other endemic flaviruses, such as dengue; (3) persistent viremia and viruria in pregnancy weeks to months after primary exposure; and (4) fetal brain malformations and anomalies preceding the sonographic detection of microcephaly. In this commentary, we discuss screening and diagnostic considerations that are grounded not only in the realities of current obstetrical practice in a largely global population but also in basic immunology and virology. We review recent epidemiological data pertaining to the risk of congenital Zika virus malformations based on trimester of exposure and consider side by side with emerging data demonstrating replication of Zika virus in placental and fetal tissue throughout gestation. We discuss limitations to ultrasound based strategies that rely largely or solely on the detection of microcephaly and provide alternative neurosonographic approaches for the detection of malformations that may precede or occur independent of a small head circumference. This expert review provides information that is of value for the following: (1) obstetrician, maternal-fetal medicine specialist, midwife, patient, and family in cases of suspected Zika virus infection; (2) review of the methodology for laboratory testing to explore the presence of the virus and the immune response; (3) ultrasound-based assessment of the fetus suspected to be exposed to Zika virus with particular emphasis on the central nervous system; and (4) identification of areas ready for development.


Assuntos
Doenças Transmissíveis Emergentes/diagnóstico , Doenças Transmissíveis Emergentes/epidemiologia , Epidemias , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/epidemiologia , Diagnóstico Pré-Natal/métodos , Infecção por Zika virus/diagnóstico , Infecção por Zika virus/epidemiologia , Doenças Transmissíveis Emergentes/congênito , Feminino , Humanos , Microcefalia/diagnóstico , Microcefalia/virologia , Gravidez , Infecção por Zika virus/congênito
19.
J Infect Dis ; 214(9): 1357-1360, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27521359

RESUMO

Zika virus has emerged in the Americas, where dengue virus is endemic. Among the 4 serotypes of dengue virus, antibody-dependent enhancement is thought to enhance viral replication and disease severity. Reports suggest that anti-dengue virus antibody may enhance Zika virus replication. We investigated whether Zika virus antibodies enhance dengue virus replication, by exposing C57Bl/6 mice to Zika virus. Polyclonal serum was verified for strong Zika virus-neutralizing, dengue virus-subneutralizing capacity. Then we determined the enhancement capabilities of Zika virus-immune serum for dengue virus in vitro. We showed that Zika virus antibodies have the ability to enhance dengue virus infections, which is important, because in many Zika virus-affected areas, dengue virus is expected to remain endemic.


Assuntos
Anticorpos Antivirais/imunologia , Formação de Anticorpos/imunologia , Anticorpos Facilitadores/imunologia , Vírus da Dengue/genética , Replicação Viral/genética , Zika virus/imunologia , América , Animais , Anticorpos Neutralizantes/sangue , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/sangue , Linhagem Celular , Dengue/sangue , Dengue/imunologia , Dengue/virologia , Vírus da Dengue/imunologia , Feminino , Humanos , Camundongos , Camundongos Endogâmicos C57BL , Testes de Neutralização/métodos , Sorogrupo , Células Vero , Ensaio de Placa Viral/métodos , Infecção por Zika virus/sangue , Infecção por Zika virus/imunologia , Infecção por Zika virus/virologia
20.
Acta Virol ; 59(3): 234-9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26435146

RESUMO

Potency testing of Japanese encephalitis (JE) vaccine has been a complex process since its inception. To overcome difficulties encountered therein, an alternative assay, serum neutralization test (SNT), using Baby Hamster Kidney 21 cell line, has been standardized. The antibody response generated against JE vaccine was quantified and the assay was found to be sensitive and specific enough with significant accuracy and precision. On analysis of cell count, a cell concentration of 1.5 x 104 was selected as the optimum, since concentrations above and below this resulted in problems of confluent monolayer formation and incomplete monolayer formation. Incubation time has also been standardized for measuring cytopathic effect (CPE). Out of the four different time points selected, 90 min was found to be adequate for 50% reduction in the amount of CPE. The accuracy of SNT assay is explained in terms of fiducial limits at 95% level. Inter- and intra-assay reproducibility testing was also performed. A comparison of potency of JE vaccine by plaque reduction neutralization test (PRNT) and SNT method was conducted and it was found that SNT can be a reliable approach for estimating the potency of JE vaccine. The results of this study throw a light on the utility of SNT assay for the potency estimation of JE vaccine in routine practice.


Assuntos
Anticorpos Antivirais/sangue , Vírus da Encefalite Japonesa (Espécie)/imunologia , Testes de Neutralização/normas , Animais , Células Cultivadas , Cricetinae , Vacinas contra Encefalite Japonesa/imunologia , Camundongos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA