Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Assunto principal
Tipo de documento
Intervalo de ano de publicação
1.
Innovations (Phila) ; 19(2): 143-149, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38504149

RESUMO

OBJECTIVE: This study evaluated the efficacy of the Minimally Invasive Targeted Resection (MiTR) device, a novel electrosurgical instrument that allows for targeted excision of a lung abnormality while using bipolar radiofrequency (RF) energy to seal blood vessels and airways. METHODS: The MiTR system was evaluated in 7 acute and 2 chronic porcine (7-day) models to evaluate the efficacy of tissue excision with bipolar RF sealing of blood vessels and airways and application of an autologous blood patch into the excised tissue cavity. Air leak was recorded for all evaluations. The study was approved by the institutional ethical board. RESULTS: Nineteen lung tissue samples, measuring 2.5 cm long × 1.2 cm diameter, were excised. In 8 of 9 animals (89%), hemostasis and pneumostasis were observed visually at the completion of the procedure. In 2 of 2 chronic animals (100%), hemostasis and pneumostasis persisted for the 7-day observation period. Histologic examination of the excised samples showed preservation of the core parenchymal architecture without evident tissue damage of the samples that would impair pathologic analysis. CONCLUSIONS: Percutaneous resection of targeted lung tissue with the MiTR system demonstrated hemostasis and pneumostasis while obtaining a histologically intact sample. After regulatory approval, the use of this device could offer more tissue for analysis than a transthoracic needle biopsy or bronchoscopy and a far less invasive alternative to video-assisted thoracic surgery or thoracotomy. This may also expand patient and physician options for the early diagnosis and treatment of lung cancer.


Assuntos
Pulmão , Animais , Suínos , Pulmão/cirurgia , Pulmão/patologia , Pneumonectomia/instrumentação , Pneumonectomia/métodos , Eletrocirurgia/instrumentação , Eletrocirurgia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Hemostasia Cirúrgica/instrumentação , Hemostasia Cirúrgica/métodos , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/instrumentação
2.
Animals (Basel) ; 13(17)2023 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-37684995

RESUMO

Pulmonary loborraphy can be performed using manual sutures and staples, although other methods, such as tissue adhesives, are also cited in the veterinary literature. Although the surgery is well tolerated in the canine species, failure in pulmonary aerostasis is still a reality since all the methods described so far eventually lead to air leakage after the use of the partial lobectomy technique in the lungs. Within this context, the aim of this research was to compare the effectiveness of different hermetic sealing methods after partial lobectomy of the right caudal lung lobe (RCLL) in dogs. 30 cadavers models were divided in 6 groups: G1-cobbler suture associated with simple continuous; G2-overlapping continuous suture associated with simple continuous suture; G3-Ford interlocking suture; G4-Stapling device; G5-Tissue glue (cyanoacrylate). After performing the sealing techniques, the lungs were submerged in water and inflated with oxygen at positive ventilatory pressures at physiological (up to 14.7 mmHg, which is equivalent to up to 20 cmH2O) and supraphysiological levels (above 14.7 mmHg) to evaluate the performance of the sealing methods. At physiological ventilatory pressure levels, there was no difference between groups. Sealing with surgical glue was superior to interlocking sutures and stapling devices at supraphysiological levels of ventilatory pressure.

3.
J Thorac Dis ; 8(7): 1540-5, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27499941

RESUMO

BACKGROUND: Decortication for thoracic empyema is associated with significant blood loss and prolonged postoperative air leak. We sought to assess the potential application of an irrigated-tip radiofrequency (RF) sealing device, in an attempt to reduce this morbidity. METHODS: Data for all patients undergoing open decortication (OD) for stage II thoracic empyema, using either conventional approach or facilitated by use of the Aquamantys(®) device, at a single thoracic surgical unit between April 2010 and July 2014, were retrospectively analysed. Unpaired t-test and Fisher's exact test were used for statistical analysis. RESULTS: Thirty-three patients, aged 54±15 years (mean ± SD), and with a Charlson comorbidity index of 2.5±1.9 were included. Preoperative and intraoperative characteristics, including surgical time, were similar in the conventional and Aquamantys(®) groups. Patients in the Aquamantys group were less likely to require red cell transfusion (9/22 vs. 10/11 patients, P=0.024) and received lower volume transfusions [0.0 (2.0) vs. 3.0 (1.6) units (median, IQR), P<0.0001]; chest drain duration was shorter [3.0 (1.0) vs. 6.5 (6.8) days, P=0.006], as was length of postoperative hospital stay [6.0 (8.7) vs. 10.0 (4.6) days, P=0.031]. There was no demonstrable difference in mortality. CONCLUSIONS: Our data indicates that the use of irrigated tip RF ablation is safe and effective in improving pneumostasis and haemostasis in decortication for thoracic empyema; and that this translates to morbidity and logistical benefit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA