Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 103
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Environ Sci Technol ; 58(20): 8846-8856, 2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38728579

RESUMO

Advanced oxidation process (AOP) wet scrubber is a powerful and clean technology for organic pollutant treatment but still presents great challenges in removing the highly toxic and hydrophobic volatile organic compounds (VOCs). Herein, we elaborately designed a bifunctional cobalt sulfide (CoS2)/activated carbon (AC) catalyst to activate peroxymonosulfate (PMS) for efficient toxic VOC removal in an AOP wet scrubber. By combining the excellent VOC adsorption capacity of AC with the highly efficient PMS activation activity of CoS2, CoS2/AC can rapidly capture VOCs from the gas phase to proceed with the SO4•- and HO• radical-induced oxidation reaction. More than 90% of aromatic VOCs were removed over a wide pH range (3-11) with low Co ion leaching (0.19 mg/L). The electron-rich sulfur vacancies and low-valence Co species were the main active sites for PMS activation. SO4•- was mainly responsible for the initial oxidation of VOCs, while HO• and O2 acted in the subsequent ring-opening and mineralization processes of intermediates. No gaseous intermediates from VOC oxidation were detected, and the highly toxic liquid intermediates like benzene were also greatly decreased, thus effectively reducing the health toxicity associated with byproduct emissions. This work provided a comprehensive understanding of the deep oxidation of VOCs via AOP wet scrubber, significantly accelerating its application in environmental remediation.


Assuntos
Oxirredução , Compostos Orgânicos Voláteis , Compostos Orgânicos Voláteis/química , Catálise , Carvão Vegetal/química , Cobalto/química , Adsorção , Carbono/química
2.
Environ Sci Technol ; 58(3): 1625-1635, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38207092

RESUMO

The catalytic removal of chlorinated VOCs (CVOCs) in gas-solid reactions usually suffers from chlorine-containing byproduct formation and catalyst deactivation. AOP wet scrubber has recently attracted ever-increasing interest in VOC treatment due to its advantages of high efficiency and no gaseous byproduct emission. Herein, the low-valence Co nanoparticles (NPs) confined in a N-doped carbon nanotube (Co@NCNT) were studied to activate peroxymonosulfate (PMS) for efficient CVOC removal in a wet scrubber. Co@NCNT exhibited unprecedented catalytic activity, recyclability, and low Co ion leakage (0.19 mg L-1) for chlorobenzene degradation in a very wide pH range (3-11). The chlorobenzene removal efficiency was kept stable above 90% over Co@NCNT, much higher than that of nonconfined Co@NCNS (45%). The low-valence Co NPs achieved a continuous electron redox cycling (Co0/Co2+ → Co3+ → Co0/Co2+) and greatly promoted the O-O bond dissociation of PMS with the least energy (0.83 eV) inside the channel of Co@NCNT to form abundant HO• and SO4•-. Thus, the deep oxidation of chlorobenzene was achieved without any biphenyl byproducts from the coupling reaction. This study provided a new avenue for designing novel nanoconfined catalysts with outstanding activity, paving the way for the deep oxidation of CVOC waste gas via AOP wet scrubber.


Assuntos
Nanotubos de Carbono , Peróxidos/química , Oxirredução , Clorobenzenos
3.
Environ Res ; : 119609, 2024 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-39002626

RESUMO

Sulphur Emission Control Areas (SECAs), mandated by the International Maritime Organization (IMO), regulate fuel sulphur content (FSC) to mitigate the environmental and health impact of shipping emissions in coastal areas. Currently, FSC is limited to 0.1% (w/w) within and 0.5% (w/w) outside SECAs, with exceptions for ships employing wet sulphur scrubbers. These scrubbers enable vessels using non-compliant fuels such as high-sulphur heavy fuel oils (HFOs) to enter SECAs. However, while sulphur reduction via scrubbers is effective, their efficiency in capturing other potentially harmful gases remains uncertain. Moreover, emerging compliant fuels like highly aromatic fuels or low-sulphur blends lack characterisation and may pose risks. Over three years, we assessed emissions from an experimental marine engine at 25% and 75% load, representative of manoeuvring and cruising, respectively. First, characterizing emissions from five different compliant and non-compliant fuels (marine gas oil MGO, hydro-treated vegetable oil HVO, high-, low- and ultra-low sulphur HFOs), we calculated emission factors (EF). Then, the wet scrubber gas-phase capture efficiency was measured using compliant and non-compliant HFOs. NOx EF varied among fuels (5200-19700 mg/kWh), with limited scrubber reduction. CO (EF 750-13700 mg/kWh) and hydrocarbons (HC; EF 122-1851 mg/kWh) showed also insufficient abatement. Carcinogenic benzene was notably higher at 25% load and about an order of magnitude higher with HFOs compared to MGO and HVO, with no observed scrubber reduction. In contrast, carbonyls such as carcinogenic formaldehyde and acetaldehyde, acting as ozone precursors, were effectively scrubbed due to their polarity and water solubility. The ozone formation potential (OFP) of all fuels was examined. Significant EF differences between fuels and engine loads were observed, with the wet scrubber providing limited or no reduction of gaseous emissions. We suggest enhanced regulations and emission abatements in the marine sector to mitigate gaseous pollutants harmful to human health and the environment.

4.
Environ Sci Technol ; 57(37): 13948-13958, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37671477

RESUMO

Humic-like substances (HULIS), known for their substantial impact on the atmosphere, are identified in marine diesel engine emissions obtained from five different fuels at two engine loads simulating real world scenarios as well as the application of wet sulfur scrubbers. The HULIS chemical composition is characterized by electrospray ionization (ESI) ultrahigh resolution mass spectrometry and shown to contain partially oxidized alkylated polycyclic aromatic compounds as well as partially oxidized aliphatic compounds, both including abundant nitrogen- and sulfur-containing species, and clearly different to HULIS emitted from biomass burning. Fuel properties such as sulfur content and aromaticity as well as the fuel combustion efficiency and engine mode are reflected in the observed HULIS composition. When the marine diesel engine is operated below the optimum engine settings, e.g., during maneuvering in harbors, HULIS-C emission factors are increased (262-893 mg kg-1), and a higher number of HULIS with a shift toward lower degree of oxidation and higher aromaticity is detected. Additionally, more aromatic and aliphatic CHOS compounds in HULIS were detected, especially for high-sulfur fuel combustion. The application of wet sulfur scrubbers decreased the HULIS-C emission factors by 4-49% but also led to the formation of new HULIS compounds. Overall, our results suggest the consideration of marine diesel engines as a relevant regional source of HULIS emissions.


Assuntos
Atmosfera , Navios , Biomassa , Substâncias Húmicas , Enxofre
5.
Toxicol Ind Health ; 39(9): 491-503, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37420335

RESUMO

To meet the strict requirements of reducing sulfur emissions, an increasing number of commercial ships have installed exhaust gas cleaning systems (EGCSs). However, wash water produced during the cleaning process is discharged back to the marine environment. We investigated the effects of closed-loop scrubber (natrium-alkali method) wash water on three trophic species. Severe toxic effects were found when Dunaliella salina, Mysidopsis bahia, and Mugilogobius chulae were exposed to 0.63-6.25, 0.63-10, and 1.25-20% concentrations of wash water, respectively. The 50% effective concentration in 96 h (EC50-96 h) for D. salina was 2.48%, and the corresponding total polycyclic aromatic hydrocarbons (PAHs) and heavy metals were 22.81 and 23.67 µg L-1. The 50% lethal concentration in 7 d (LC50-7 d) values for M. bahia and M. chulae were 3.57% and 20.50%, respectively. The lowest observed effect concentration (LOEC) values for M. bahia and M. chulae were 1.25% and 2.5%, respectively, and the corresponding total PAHs and heavy metals were 11.50 and 11.93 and 22.99 and 23.86 µg L-1. M. bahia's body weight was negatively correlated with the amount of wash water. Low concentrations of wash water (0-5%) had no significant effect on the reproduction of M. bahia. Although concentrations of 16 PAHs and 8 heavy metals are known, different compounds might react with each other and form more unknown toxic substances, and the measured toxicity comes from synergistic effects between various pollutants. Therefore, future work is needed to clarify other more toxic contaminants in wash water. We highly recommend that wash water be treated before being discharged to the marine environment.


Assuntos
Metais Pesados , Hidrocarbonetos Policíclicos Aromáticos , Poluentes Químicos da Água , Navios , Monitoramento Ambiental , Emissões de Veículos/toxicidade , Metais Pesados/toxicidade , Metais Pesados/análise , Hidrocarbonetos Policíclicos Aromáticos/toxicidade , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Químicos da Água/toxicidade , Poluentes Químicos da Água/análise , Água
6.
J Environ Manage ; 348: 119339, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37883837

RESUMO

Algae have been well studied for their abilities to treat wastewater, and several types of treatment systems have been demonstrated at a range of scales. High Rate Algae Ponds (HRAP) are a microalgae-based system and Filamentous Algae Nutrient Scrubbers (FANS) a filamentous algae-based system. For FANS, nutrient removal rates are typically lower and more variable than HRAPs, while HRAPs have lower productivity and poor harvestability. This study investigated if modifying a FANS to mimic HRAPs (using high rate algae mesocosms HRAM), with respect to hydraulic retention time (HRT) and smaller footprint, overcomes FANS limitations, while increasing wastewater treatment and resource recovery compared to HRAPs. Biomass productivity on the FANS (10.5 ± 2.9 g m-2 d-1) and FANS with CO2 addition (19.0 ± 4.8 g m-2 d-1) were significantly higher (p < 0.01) compared to the HRAMs (6.7 ± 1.4 g m-2 d-1) and HRAMs with CO2 addition (8.1 ± 1.2 g m-2 d-1). Under phosphorus replete conditions, biomass production was significantly higher on FANS (44.8 ± 14.4 g m-2 d-1) than HRAMs (5.0 ± 0.6 g m-2 d-1). Effluent quality (nutrient removal) was significantly higher (p < 0.05) for FANS compared to HRAMS, regardless of treatment. For harvesting, FANS (2.9-41%) yielded significantly higher (p < 0.01) percentage solids with, and, without dewatering/gravity harvesting compared to the HRAM (0.04-0.11%). Modifying the operation of the FANS to mimic longer HRT of HRAMs resulted in higher areal biomass productivity and nutrient removal in the FANS than the HRAM, regardless of treatment. The use of filamentous algae on FANS greatly improved the percentage solids yield in the harvested biomass without the need for energy intensive harvesting techniques. Further investigations need to be undertaken to determine if benefits will be realised at fullscale.


Assuntos
Microalgas , Purificação da Água , Eliminação de Resíduos Líquidos/métodos , Dióxido de Carbono , Águas Residuárias , Biomassa , Lagoas
7.
J Environ Manage ; 326(Pt A): 116705, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36379079

RESUMO

Filamentous algae nutrient scrubber (FANS) operating parameters can strongly influence algal biomass productivity and nutrient removal. However, few studies to date have investigated the effects of FANS operating parameters such as initial standing crop, harvesting frequency and influent flow rate on biomass productivity and nutrient removal performance, especially for FANS that cultivate a single species of algae. Therefore, the overall aim of this study was to investigate how operating parameters affect the biomass productivity and nutrient removal performance of Oedogonium sp. - a promising species for unialgal FANS. The initial standing crop had a significant effect on biomass productivity, with productivities being highest (8.6 ± 0.5 g DW biomass m-2day-1) when the initial standing crop was 60-70 g DW m-2. However, the daily nutrient removal rate was highest (0.47 ± 0.06 g N m-2 day-1and 1.24 ± 0.13 g P m-2 day-1) at the highest initial standing crop (100-110 DW m-2). Biomass productivity was highest with a three-day growth period, regardless of size of the initial standing crop. Therefore, a four-day harvesting interval was selected as the optimal harvesting regime to promote exponential growth and high biomass production. Influent flow rate had a significant effect on biomass productivity, which was highest (9.3 ± 1.7 g DW m-2 day-1) for the 1 L min-1 flow rate. This flow rate also gave the highest instantaneous nutrient removal rate (0.05 ± 0.02 g N m-3 and 0.14 ± 0.05 g P m-3). Current results suggest that an optimum initial standing crop of 70-80 g DW m-2, harvesting frequency of four days and influent flow rate of 1 L min-1 (16.7 L min-1 m-1 width) were optimal for Oedogonium sp. cultivated on FANS to maximize their biomass production and nutrient removal under controlled laboratory conditions. These results contribute to understanding the impacts of operating parameters on optimizing unialgal Oedogonium sp. FANS biomass production and nutrient removal performance.


Assuntos
Microalgas , Nitrogênio , Biomassa , Nutrientes
8.
Environ Sci Technol ; 56(19): 13996-14007, 2022 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-36083161

RESUMO

In this study, a wet scrubber coupled with a persulfate-based advanced oxidation process [carbocatalysts/peroxymonosulfate (PMS)] was demonstrated to efficiently remove gaseous volatile organic compounds (VOCs). The removal efficiency of a representative VOC, styrene, was stable at above 98%, and an average mineralization rate was achieved at 76% during 2 h. The removal efficiency of the carbocatalysts/PMS wet scrubber for styrene was much higher than that of pure water, carbocatalysts/water, or PMS/water systems. Quenching experiments, electron spin resonance spectroscopy, in-situ Raman spectroscopy and density functional theory (DFT) calculations indicated that singlet oxygen (1O2) and oxidative complexes are the main reactive oxygen species and that both contributed to styrene removal. In particular, carbonyl groups (C═O) in the carbocatalyst were found to be the active sites for activating PMS during styrene oxidation. The role of 1O2 was discovered to be benzene ring breaking and a possible non-radical oxidation pathway of styrene was proposed based on time-of-flight mass spectroscopy which was further verified by DFT calculations. In particular, the electron transfer process of multi world carbon nanotubes-PMS* in styrene oxidation was further studied in-depth by experiments and DFT calculations. The unstable vinyl on styrene was simultaneously degraded by the oxidative complexes and 1O2 into benzene, and finally oxidized by 1O2 into H2O and CO2. This study provides an effective method for VOC removal and clearly illustrates the complete degradation mechanism of styrene in a nonradical PMS-based process by a wet scrubber.


Assuntos
Nanotubos de Carbono , Compostos Orgânicos Voláteis , Benzeno , Dióxido de Carbono , Gases , Peróxidos/química , Espécies Reativas de Oxigênio , Oxigênio Singlete , Estirenos , Água
9.
Environ Res ; 214(Pt 2): 113806, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35863447

RESUMO

The particulate polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) of various sizes produced from the waste incinerators might have different toxicities, deposition characteristics, and potential health effects in the respiratory system, and their total toxicity equivalent (TEQ) concentration has been strictly regulated in recent years. There is a knowledge gap on the effects of air pollution control devices on particle size distributions (PSDs) of PCDD/Fs and their TEQ deposition. A hazardous waste thermal treatment plant equipped with an advanced scrubber, a cyclone demister, and activated carbon adsorption coupled with a baghouse filtration was investigated in this study. An 8-stage impactor was used to collect the particle distribution of PM10 and bounded PCDD/Fs from the gas stream at four sampling points located before and after each control unit. A "TEQDE" index is defined for the toxicity deposition of PM10-PCDD/F in the respiratory system. The advanced scrubbers significantly reduced the PM10-PCDD/F levels, especially for those with sizes ≥0.6 and ≤ 0.4 µm. Additionally, the cyclone also showed a better performance than the general dry gas treatment but had an efficiency drop with 1.5-4 µm particles. The PM10-PCDD/F loads in the final adsorption-filtration unit were eased and effectively removed the PM10-PCDD/Fs to sizes ≤0.5 or≥1.5 µm. The total TEQDE was 0.00052 ng WHO-TEQ Nm-3 and had a peak level of 0.000157 ng WHO-TEQ Nm-3 at 1.2 µm. PSDs were more sensitive to the PSDs of PM mass at high PM levels but strongly correlated with the PSDs of "PM10-PCDD/Fs/PM10" at low PM10 loads. Consequently, the advanced control system could effectively remove the PM10-PCDD/Fs and might extend the adsorption-filtration lifetime. However, the PM10-PCDD/Fs ≤ 0.4 µm had a higher TEQ deposition rate and should be further considered in emissions and ambient air quality evaluations.


Assuntos
Poluentes Atmosféricos , Benzofuranos , Dibenzodioxinas Policloradas , Poluentes Atmosféricos/análise , Benzofuranos/análise , Dibenzofuranos , Dibenzofuranos Policlorados , Poeira , Monitoramento Ambiental , Resíduos Perigosos , Incineração , Dibenzodioxinas Policloradas/análise , Sistema Respiratório
10.
J Environ Manage ; 305: 114426, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34998062

RESUMO

Poor performance of wet scrubbers in rubber processing plants due to breakthrough of specific volatile organic compounds (VOCs) causes odour impact events. The performance of wet scrubbers in the rubber drying process to remove VOCs was investigated in order to determine the responsible odorants. VOC emissions originating at the inlet and outlet of wet scrubbers were quantified using gas chromatography-mass spectrometry/olfactometry (GC-MS/O). Critical VOCs were identified alongside seasonal and daily variations of those VOCs. Altogether, 80 VOCs were detected in rubber emissions with 16 classified as critical VOCs based on their chemical concentration, high odour activity value (OAV) and unpleasant odour. Volatile fatty acids (VFAs) were the dominant VOCs with seasonal variations affecting emission composition. Results demonstrated the ineffectiveness of the wet scrubbers to mitigate odorous VOCs whereas the removal of some VOCs could be improved based on their polarity and solubility. It was found that there is a correlation between the wet scrubber performance and VFAs concentration in the emissions. The findings demonstrated that combining quantitative and sensory analyses improved accuracy in identifying odorous VOCs, which can cause odour annoyance from rubber processing. A VOC identification framework was proposed using both analyses approaches.


Assuntos
Poluentes Atmosféricos , Compostos Orgânicos Voláteis , Poluentes Atmosféricos/análise , Cromatografia Gasosa-Espectrometria de Massas , Odorantes/análise , Borracha , Compostos Orgânicos Voláteis/análise
11.
J Environ Manage ; 312: 114882, 2022 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-35344877

RESUMO

We investigated the effect of algal contact time (ACT) and horizontal water velocity (HWV) on the performance of pilot-scale Filamentous Algae Nutrient Scrubbers (FANS) treating river water during the NZ summer. The FANS floways were seeded with a mixture of four New Zealand native filamentous algal species (Oedogonium sp., Cladophora sp., Rhizoclonium sp., and Spirogyra sp.) and allowed to establish over one month. River water was pumped onto the top of each FANS at different flow rates (2, 4 or 8 L min-1) to give ACTs from 0.6 to 10.1 min depending on FANS length (6-24 m) and HWV from 0.04 to 0.16 m s-1. FANS inflow and final outflows were monitored three times a week for nitrate and DRP concentrations and FANS algal biomass was harvested weekly. Average biomass productivity was significantly higher on the FANS with shorter ACT. For example, biomass productivity of the 24 m length FANS with 2.5 min ACT were 67% higher (11.2 g DW m-2 d-1) than that with four times the ACT (10.1 min). Irrespective of the HWV the biomass productivity declined down the length of the floways (with longer ACT) and the decline was greater at lower HWV. The decreased biomass productivity at lower HWV (and/or higher ACT) was likely attributable to the daytime carbon limitation of photosynthesis (at pH > 9.5) and heat stress with elevated daytime water temperature (at >30 °C). Despite the short ACT (<10.1 min) the single pass pilot-scale FANS effectively removed both nitrate-N and DRP from the river water, with >35% removal of both NO3-N (from 0.49 to <0.32 mg N L-1) and DRP (from 0.14 to <0.09 mg P L-1). Both the nitrogen and phosphorus content of the harvested algal biomass were unaffected by both HWV and ACT and typical (N: ∼2.0%; P: 0.2-0.3%) of the literature values (N: 1.5-3.0%; P: 0.15-0.32%). Compared with constructed wetland nutrient removal (0.1 g N m-2 d-1; 0.08 g P m-2 d-1), the FANS achieved up to 2.5-fold higher nitrogen removal (0.24 N m-2 d-1) through algal nitrogen assimilation followed by subsequent algal harvest and up to 4-fold higher phosphorus removal (0.34 g P m-2 d-1) through a combination of algal phosphorus assimilation and some P-precipitation under photosynthesis-mediated elevated daytime pH levels (pH > 9.0). This research indicates that FANS have the potential to require less than half the land area of constructed wetlands for the same level of nitrogen removal and that they require only a few weeks to establish to achieve full performance. Moreover, FANS have the further benefit of resource recovery for beneficial re-use of harvested algal biomass for animal feed, fertiliser, or biofuel.


Assuntos
Clorófitas , Água , Biomassa , Nitratos , Nitrogênio , Nutrientes , Compostos Orgânicos , Fósforo
12.
Environ Monit Assess ; 194(9): 641, 2022 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-35930143

RESUMO

Many shipping companies have started using scrubbers in their fleet to eliminate sulfur emissions from ships, per IMO (International Maritime Organization) rules. Before and during the scrubbers' selection, the scrubbers' operational failures have also started to appear and cause serious concerns. In this study, classified scrubber types are explained and open type, closed type, and hybrid scrubber systems are evaluated. To contribute to this gap in the literature, scrubber failures were identified, five experts with different perspectives were consulted, and the most common and critical malfunctions were evaluated with the fuzzy best-worst method (F-BWM) and fuzzy technique for order preference by similarity to an ideal solution (F-TOPSIS). F-BWM was used to determine the importance weights of the risk parameters used in evaluating failures since it provides fewer comparisons among pairwise comparison-based decision-making methods and a more consistent judgment in the evaluation. F-TOPSIS, on the other hand, was used to determine the final priority scores of the scrubber failures, taking into account the risk parameter weights obtained in the first stage. It has been preferred due to its easy to useness and based on its closeness to the ideal solution and applicability to risk and failure analysis problems. Considering all different systems in general, important issues such as collection efficiency, sulfur emission problem, abrasion, leakages, pump failures, heat exchanger failures, air fan sealing failures, sensors and failures in monitoring the whole system have been investigated. Results show that too high axial velocity for separator and flooded separator, too high solids concentration in recirculation liquid (SF2), piping leakages (SF5), poor quality or inappropriate consumables and chemicals (SF11), and feed circulation pump problems (SF6) are found to be the most important problems among thirteen failures.


Assuntos
Monitoramento Ambiental , Navios , Lógica Fuzzy , Enxofre
13.
J Environ Sci (China) ; 113: 132-140, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34963523

RESUMO

The concentration variation of C3-C11 non-methane hydrocarbons (NMHCs) collected in several types of commercial flexible bags and adsorption tubes was systematically investigated using a gas chromatography-flame ionization detector (GC-FID) system. The percentage loss of each NMHC in the polyvinyl fluoride (PVF) bags was less than 5% during a 7-hr storage period; significant NMHCs loss was detected in aluminum foil composite film and fluorinated ethylene propylene bags. The thermal desorption efficiency of NMHCs for adsorption tubes filled Carbopack B and Carboxen1000 sorbents was greater than 95% at 300℃, and the loss of NMHCs in the adsorption tubes during 20-days storage at 4℃ was less than 8%. The thermal desorption efficiency for C11 NMHCs in the adsorption tube filled with Carbograph 1 and Carbosieve SⅢ absorbents was less than 40% at 300℃, and pyrolysis of the absorbents at 330℃ interfered significantly with the measurements of some alkenes. The loss of alkenes was significant when NMHCs were sampled by cryo-enrichment at -90℃ in the presence of O3 for the online NMHC measurements, and negligible for enrichment using adsorption tubes at 25℃. Although O3 scrubbers have been widely used to eliminate the influence of O3 on NMHC measurements, the loss of NMHCs with carbon numbers greater than 8 was more than 10%. Therefore, PVF bags and adsorption tubes filled Carbopack B and Carboxen1000 sorbents were recommended for the sampling of atmospheric NMHCs.


Assuntos
Poluentes Atmosféricos , Metano , Adsorção , Poluentes Atmosféricos/análise , Carbono , Cromatografia Gasosa , Monitoramento Ambiental , Hidrocarbonetos/análise
14.
J Environ Manage ; 296: 113193, 2021 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-34237671

RESUMO

Following the escalating human population growth and rapid urbanization, the tremendous amount of urban and industrial waste released leads to a series of critical issues such as health issues, climate change, water crisis, and pollution problems. With the advantages of a favorable carbon life cycle, high photosynthetic efficiencies, and being adaptive to harsh environments, algae have attracted attention as an excellent agent for pollution prevention and waste phycoremediation. Following the concept of circular economy and biorefinery for sustainable production and waste minimization, this review discusses the role of four different algal-based wastewater treatment technologies, including high-rate algal ponds (HRAPs), HRAP-absorption column (HRAP-AC), hybrid algal biofilm-enhanced raceway pond (HABERP) and algal turf scrubber (ATS) in waste management and resource recovery. In addition to the nutrient removal mechanisms and operation parameters, recent advances and developments have been discussed for each technology, including (1) Innovative operation strategies and treatment of emerging contaminants (ECs) employing HRAPs, (2) Biogas upgrading utilizing HRAP-AC system and approaches of O2 minimization in biomethane, (3) Operation of different HABERP systems, (4) Life-cycle and cost analysis of HRAPs-based wastewater treatment system, and (5) Value-upgrading for harvested algal biomass and life-cycle cost analysis of ATS system.


Assuntos
Microalgas , Purificação da Água , Biomassa , Humanos , Lagoas , Tecnologia , Eliminação de Resíduos Líquidos , Águas Residuárias
15.
Artigo em Inglês | MEDLINE | ID: mdl-34304695

RESUMO

Control over particulate matter (PM) emission from grilling is required for improving public health and air quality. The performance of mirror-symmetrical multi-compartment scrubbers with an upflow (U-type) and downflow baffle (D-type) configuration was evaluated for PM emission control from grilling at a flow rate of 30 m3 min-1. The PM removal efficiency of the U-type scrubber was the highest when the water level was 8 cm (95.6%), and the pressure drops recorded at the water levels of 6, 8 and 10 cm were 103, 122 and 153 mmH2O, respectively. Although PM removal efficiency of the D-type scrubber was over 91.0% at the water levels of 8, 10 and 12 cm, the pressure drops were 124, 142 and 185 mmH2O, respectively. A comprehensive evaluation of the water volume, pressure drop and PM removal performance, as well as device size, revealed that the U-type scrubber with a PM removal efficiency of 92% or higher and a pressure drop of 122 mmH2O or lower at the water levels of 6-8 cm was more economical for removing PM from grilling gas than the D-type scrubber.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Poluentes Atmosféricos/análise , Material Particulado/análise
16.
Artigo em Inglês | MEDLINE | ID: mdl-32475209

RESUMO

Grilling restaurants are a major contributor to airborne particulate matter (PM) in metropolitan areas. In this study, the removal of PM during the grilling of pork belly using an orifice scrubber, which is a form of gas-induced spray scrubber, was assessed. During grilling, the particle mass concentration was the highest for 1.0 < PM ≤ 2.5 µm (55.5% of total PM emissions), followed by 0.5 < PM ≤ 1.0 (27.1%), PM ≤ 0.5 (10.7%), and PM > 2.5 µm (7.0%). The PM removal efficiency of the orifice scrubber at a gas flow of 4.5 m3 min-1 was > 99.7% for PM ≥ 2.5 µm, 89.4% for 1.0 < PM ≤ 2.5 µm, 62.1% for 0.5 < PM ≤ 1.0, and 36.5% for PM ≤ 0.5 µm. Although further research is necessary to optimize its use, the orifice scrubber offers a user-friendly technology for the control of PM in small grilling restaurants because of its simple design, uncomplicated operation, and satisfactory PM removal performance.


Assuntos
Poluentes Atmosféricos/isolamento & purificação , Poluição do Ar/prevenção & controle , Material Particulado/isolamento & purificação , Restaurantes , Gerenciamento de Resíduos/instrumentação , Animais , Culinária , Tamanho da Partícula , Carne Vermelha , República da Coreia , Suínos
17.
J Environ Manage ; 241: 32-43, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30981141

RESUMO

A detailed techno-economic comparison of a chemical scrubber (CS) and a bio-filter (BF) was conducted over a 45-day time period at a municipal wastewater treatment plant (WWTP), Yazd city. The assessment of emissions quantity indicated that odor emissions from the Yazd WWPT mainly consist of hydrogen sulfide (H2S) and ammonia (NH3). It was also found that odor gaseous loading changes corresponding to water consumption pattern in society (R2 = 0.922) for H2S and (R2 = 0.978) for NH3. The highest level of 25 and 3 ppm for H2S and NH3, respectively were detected at specific times during the day. The BF system was continuously supplied with Yazd WWPT's off-gas treatment while the CS was only examined at the times during the day when the gas emissions are at the highest level. The removal efficiency of NH3 and H2S were found to be affected by their respective loading rate. Additionally, among the various oxidants examined in the CS, the NaOCl solution showed the best results in terms of removal efficiency and compatibility. The experiment revealed almost complete removal of NH3 while the H2S removal efficiency remained above 95% for both systems regardless of the operating conditions. This study clearly demonstrates the effectiveness of both systems in treating actual waste gases containing H2S and NH3. By comparing the gas loading rate of both systems and considering limitations of the BF system, the CS seems to be more efficient applicable odor control technology from a technical viewpoint. From the economic viewpoint, comparisons revealed that chemical usage and operating expenses were costly parts of the CS and the BF, respectively. The economic indexes of 1.58 €.m-3. h-1 and 2.57 €.m-3. h-1 were obtained for the BF and CS, respectively, reflecting cost-effectiveness of the BF system.


Assuntos
Poluentes Atmosféricos , Sulfeto de Hidrogênio , Amônia , Análise Custo-Benefício , Filtração , Águas Residuárias
18.
J Environ Manage ; 233: 612-625, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30597355

RESUMO

The performance of ethanethiol removal in an anoxic lab-scale bio-scrubber was investigated under different operating parameters and conditions for 300 days. The removal efficiency (RE) of ethanethiol was examined as a function of inlet concentration, empty bed residence time (EBRT) and spray density of irrigation. The results showed the best operation conditions and operation characteristics of the bio-scrubber for this study were at an inlet concentration of 150 mg/m3, a spray density of 0.23 m3/m2 h and an EBRT of 90 s. An average RE of 91% and elimination capacity (EC) of 24.74 g/m3 h was found for all inlet ethanethiol concentrations. Variations in spray density higher than 0.23 m3/m2 h had no effect on ethanethiol RE at different ethanethiol concentrations. The average experimental yield values were closer to the YET/NO3- theoretical value of 0.74 when the main product was elemental sulphur (So). This indicates that So and other forms of sulphur were formed rather than sulphate (SO42-) as the end product. Furthermore, growth kinetics for bio-degradation were evaluated in batch culture experiments using the Monod model, and bio-kinetic parameters of µmax, Ks, Yxs and qmax were obtained as 0.14 1/h, 1.17 mg/L, 0.52 gx/gs and 0.26 gs/gx h, respectively.


Assuntos
Compostos de Sulfidrila , Enxofre , Filtração , Cinética
19.
J Environ Manage ; 213: 530-540, 2018 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-29477352

RESUMO

A process-simulation model for a novel process consisted of an anaerobic bioscrubber was developed in Aspen Plus®. A novel approach was performed to implement the anaerobic reactor in the simulation, enabling it to be connected to the scrubber. The model was calibrated and validated using data from an industrial prototype that converted air emissions polluted with volatile organic compounds with an average daily concentration of 1129 mgC Nm-3 into bioenergy for more than one year. The scrubber, which showed a removal efficiency within 83-93%, was successfully predicted with an average absolute relative error of 5.2 ±â€¯0.08% using an average height-to-theoretical-plate value of 1.05 ±â€¯0.08 m and 1.37 ±â€¯0.11 m for each of the two commercial packing materials used, respectively. The anaerobic reactor, which treated up to 24 kg of chemical oxygen demand m-3 d-1 with efficiencies of about 93%, was accurately simulated, both in effluent-stream characteristics and in the biogas stream. For example, the average absolute error between the experimental biogas production and the model values was 19.6 ±â€¯18.9%. The model proved its capability as a predictive tool and an aid in design, resulting in savings of time and money for practitioners. In addition, the approach proposed can be expanded to other bioprocesses that include unit operations.


Assuntos
Biocombustíveis , Compostos Orgânicos Voláteis , Anaerobiose , Reatores Biológicos , Metano
20.
J Occup Environ Hyg ; 15(4): 285-292, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29286879

RESUMO

The portable high-efficiency air filtration (PHEAF) device is used to control particulate matter (PM) generated from construction-type activities occurring within the built environment. Examples of activities where PHEAF devices are mobilized include building renovation, asbestos abatement, remediation of microbial contamination, and lead-based paint projects. Designed for use on short-term, temporary projects the PHEAF device captures airborne PM using a high-efficiency particulate air (HEPA) filter. This study sought to evaluate the capture efficiency of the PHEAF device in a field setting. An aerosol generator and photometer were used to measure particle penetration through 85 PHEAF devices. Average overall capture efficiency ranged from 41.78% to ≥99.97% with more than 88% of the tests failing to achieve 99.97% capture efficiency. Approximately 73% of the PHEAF device sample population failed to demonstrate HEPA performance criteria during any test round. A higher occurrence of PM concentrations measured around the perimeter of the filter suggested the presence of bypass leakage. While PHEAF devices were effective in capturing a significant quantity of aerosol test agent, these findings suggest that routine testing of the PHEAF device should be conducted to validate performance.


Assuntos
Filtração/instrumentação , Exposição Ocupacional/prevenção & controle , Material Particulado , Poluentes Ocupacionais do Ar , Indústria da Construção/instrumentação , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA