Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.559
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 80(2): 405-412, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38485069

RESUMO

OBJECTIVE: This study aimed to report the long-term outcomes beyond 10 years of endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms using the low-profile INCRAFT device. METHODS: This was a single-center, retrospective cohort study of all patients undergoing EVAR using the INCRAFT device as part of the regulatory trial between 2012 and 2013. Primary endpoint was aneurysm-related death. Secondary endpoints were all-cause death, reintervention, late open conversion, and aneurysm status (shrinkage, stable, and growth). RESULTS: Thirty patients with a mean age of 71.8 ± 7.7 years were included in this study. The median aneurysm diameter at EVAR was 54.5 mm (interquartile range, 53-56.8 mm). All abdominal aortic aneurysms in this study were treated following the device's instructions for use. At index EVAR, the INCRAFT device was successfully implanted in all patients using a percutaneous approach under local anesthesia. No patients experienced major adverse events or procedure-related complications 30 days after EVAR. During the median follow-up of 125 months (interquartile range, 98-131 months) with follow-up rates of 100% at 5 years and 96.7% at 10 years, aneurysm-related mortality was 0%, and freedom from all-cause mortality was 82.9% at 5 years and 75.3% at 10 years. Reintervention was required in 10 patients with 15 procedures. Sac growth was observed in 11 patients (36.7%), six of whom eventually required late open conversion; five of these patients underwent open aneurysmorrhaphy with stent graft preservation, and one underwent open surgical repair with endograft explantation. Late rupture was identified in one case, where type Ia endoleak led to rupture at 69 months, and open repair was successfully performed. Freedom from reintervention was 89.0% at 5 years but declined to 60.9% at 10 years; freedom from late open conversion was 100% at 5 years but declined to 70.8% at 10 years. CONCLUSIONS: Long-term outcomes of the INCRAFT stent graft showed no aneurysm-related deaths. However, sac growth occurred persistently throughout the follow-up period, resulting in a relatively high rate of reinterventions in the later periods, which highlights the importance of lifelong postoperative surveillance and appropriate reinterventions when indicated.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Desenho de Prótese , Stents , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Estudos Retrospectivos , Idoso , Masculino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Fatores de Tempo , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Fatores de Risco , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Reoperação
2.
J Vasc Surg ; 80(2): 344-354, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38552884

RESUMO

OBJECTIVE: This study aims to report the efficacy and safety of double-fenestrated physician-modified endovascular grafts (PMEGs) for total aortic arch repair with at least 3 years of follow-up. METHODS: All consecutive patients with a pathological aortic arch who underwent aortic arch repair combined with a homemade double-fenestrated stent graft from 2017 to 2020 were reviewed. RESULTS: 74 patients were treated for pathological arch conditions with a double-fenestrated PMEG. Of these, 81% were male, the mean age was 69.9 years, and 59% were classified as American Society of Anesthesiology 3 or 4. Thirty-five percent were treated for a postdissection aneurysm, 36% for a degenerative aneurysm, and 14% for acute type B dissection. Fifteen percent had supra-aortic trunk dissection. Fenestration on the subclavian artery was performed in 96%; if not, a carotid-subclavian bypass was carried out. Technical success was 100%. The proximal landing zone is consistently in zone 0. Early outcomes revealed a 3% occurrence of type 1 endoleak, which was successfully treated by prompt reintervention. One retrograde dissection occurred, and one patient died from hemorrhage on an iliac conduit. A 5% stroke rate was reported. During long-term follow-up (mean time 40.7 months), one type 1 endoleak appeared and was successfully treated; no type 2 or type 3 endoleak requiring intervention occurred. No stent fractures or migrations were reported. Four percent of patients required reintervention, but no surgical conversion to open surgical repair was needed on the aortic arch. No patient died from a cause related to the main procedure. CONCLUSIONS: Total aortic arch repair with double-fenestrated PMEGs is associated with acceptable early and midterm major morbidity and mortality. It is suitable for the main aortic pathologies. Moreover, it is easily available for emergency situations.


Assuntos
Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Procedimentos Endovasculares , Complicações Pós-Operatórias , Desenho de Prótese , Stents , Humanos , Masculino , Idoso , Feminino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Resultado do Tratamento , Estudos Retrospectivos , Fatores de Tempo , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Dissecção Aórtica/cirurgia , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Fatores de Risco
3.
J Vasc Surg ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39069017

RESUMO

OBJECTIVE: This study aimed to analyze early and midterm results of custom-made proximal scallop and fenestrated stent grafts for thoracic endovascular aortic repair (TEVAR) with a proximal landing zone (PLZ) in the aortic arch. METHODS: All consecutive patients treated with the custom made proximal scalloped and fenestrated Relay stent grafts (Terumo Aortic Bolton Medical Inc.) in 10 Italian centers between January 2014 and December 2022 were included. The primary end points were technical success, incidence of intraoperative major adverse events, deployment accuracy, and rate of early neurological complications, endoleaks (ELs) and retrograde aortic dissection. RESULTS: During the study period, 49 patients received TEVAR with Relay custom-made endograft in Italy were enrolled. The median patient age was 70.1 years (interquartile range, 23-86 years) and 65.3% were male. The indication for treatment was atherosclerotic aneurysms in 59.2% of cases and penetrating aortic ulcer in 22.4%. The endograft configuration was proximal fenestration in 55.1% and scallop in 44.9%. The proximal landing zone was zone 0 in 25 cases (51%), zone 1 in 14 cases (28.6%), and zone 2 in 10 cases (20.4%). The supra-aortic debranching procedures were 38 (77.5%). Technical success was 97.9% (48/49) owing to one case (2.0%) of inaccurate deployment. Intraoperatively, one (2.0%) type Ia and one (2.0%) type III EL were detected. There were no cases of in-hospital mortality, major adverse events, or retrograde dissection. Three minor strokes (6.1%) (National Institutes of Health Stroke Scale score of ≤4) were observed. At a mean follow-up time of 36.3 ± 21.3 months the rate of types I to III ELs and reintervention was 4.1%, respectively. Four patients (8.2%) died during the follow-up period, one (2.1%) from abdominal aortic rupture and three (6.1%) from nonaortic causes. CONCLUSIONS: Our early and midterm outcomes suggest that scalloped and fenestrated TEVAR may provide an acceptable alternative treatment option for aortic arch pathologies. Large-scale studies are needed to assess the long-term durability of this technique.

4.
J Vasc Surg ; 80(4): 949-956, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38750942

RESUMO

OBJECTIVE: Prevention of late type Ia endoleaks is the main concern in thoracic endovascular aortic aneurysm repair (TEVAR) for thoracic aortic aneurysm. Since 2017, we have performed zone 0 TEVAR with proximal fixation augmentation using a Najuta thoracic fenestrated stent graft in addition to zone 2 TEVAR for distal arch aneurysms. We report the early and midterm outcomes of TEVAR performed using this strategy. METHODS: This single-center retrospective study enrolled 386 cases of TEVAR for thoracic aortic disease between January 2013 and December 2020. Patients with thoracic aortic aneurysm treated by TEVAR landing at zone 2 was referred to as the standard group, whereas those treated by TEVAR landing at zone 0 using a Najuta fenestrated stent graft in addition to zone 2 TEVAR was referred to as the augmentation group. We retrospectively compared the clinical outcomes between the two groups. The primary end point was secondary intervention for postoperative type Ia endoleaks. Secondary end points were technical success, aneurysm-related death, and major adverse events (MAEs), including stroke, paraplegia, endoleaks, and secondary interventions. RESULTS: We performed TEVAR in 41 and 30 cases in the standard and augmentation groups, respectively. The mean aneurysm sizes in the standard and augmentation groups were 54.5 and 57.3 mm (P = .23), and the proximal neck lengths were 16.8 and 17.4 mm (P = .65), respectively. The anatomical characteristics seemed to be similar in both groups. The technical success rate in both groups was 100%. Three cases in the standard group had MAEs, including two stroke and one brachial artery pseudoaneurysm; whereas two cases had MAEs in the augmentation group, including one stroke and one paraplegia. There was no 30-day mortality or retrograde type A dissection in both groups. The mean observation periods in the standard and augmentation groups were 46 months (range, 1-123 months) and 35 months (range, 1-73 months), respectively. At 36 and 60 months after the procedure, the freedom from aneurysm-related death was 97.6% and 97.6% in the standard group, 100.0% and 100.0% in the augmentation group (P = .39); and the freedom from reintervention for type Ia endoleaks was 79.2% and 65.2% in the standard group, 100.0% and 100.0% in the augmentation group (P = .0087). A statistically significant decrease in reinterventions for type Ia endoleaks was observed in the augmentation group. CONCLUSIONS: Proximal fixation augmentation using the Najuta fenestrated stent graft during TEVAR for distal arch aneurysm is effective in preventing the postoperative late type Ia endoleaks.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Prótese Vascular , Endoleak , Procedimentos Endovasculares , Desenho de Prótese , Stents , Humanos , Estudos Retrospectivos , Feminino , Masculino , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Procedimentos Endovasculares/métodos , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Idoso , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Resultado do Tratamento , Endoleak/etiologia , Endoleak/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Fatores de Risco , Aneurisma do Arco Aórtico
5.
J Vasc Surg ; 79(5): 1005-1012, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38157994

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has been used extensively in the management of thoracic aortic diseases. Numerous efforts have been made to enhance clinical outcomes through the use of stent grafts. This study aimed to investigate the effectiveness and safety of physician-manufactured partial micropore stent grafts (PSMGs) in TEVAR. METHODS: Between December 2017 and June 2022, data were collected from 56 patients who underwent TEVAR using physician-manufactured PSMGs. The evaluation encompassed technical success, perioperative and follow-up morbidity and mortality, stroke incidence, and branch artery patency. RESULTS: In this investigation, 56 patients received treatment with physician-manufactured PSMGs. Of these patients, 46 were male, with a mean age of 62.1 ± 11.2 years. Aortic pathologies comprised aortic dissection (n = 31 [55.4%]), aortic aneurysms (n = 10 [17.9%]), penetrating aortic ulcer (n = 8 [14.3%]), and intramural hematoma (n = 7 [12.5%]). During a median follow-up of 18 months (interquartile range, 13-25 months), the stroke rate, supra-aortic branch patency rate, and endoleak rate were 0%, 100%, and 7.1%, respectively. There were no occurrences of all-cause mortality, stroke, or the necessity for open conversion. CONCLUSIONS: TEVAR with physician-manufactured PSMGs is a viable alternative for addressing aortic arch pathologies in proficient medical centers. The approach demonstrates favorable branch patency, a low complication rate, and minimal postoperative mortality.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Prótese Vascular , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Stents/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos , Desenho de Prótese , Fatores de Tempo , Estudos Retrospectivos , Acidente Vascular Cerebral/etiologia
6.
J Surg Res ; 296: 66-77, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38219508

RESUMO

INTRODUCTION: The aim of this study is to develop a model for predicting the risk of prolonged mechanical ventilation (PMV) following surgical repair of acute type A aortic dissection (AAAD). METHODS: We retrospectively collected clinical data from 381 patients with AAAD who underwent emergency surgery. Clinical features variables for predicting postoperative PMV were selected through univariate analysis, least absolute shrinkage and selection operator regression analysis, and multivariate logistic regression analysis. A risk prediction model was established using a nomogram. The model's accuracy and reliability were evaluated using the area under the curve of the receiver operating characteristic curve and the calibration curve. Internal validation of the model was performed using bootstrap resampling. The clinical applicability of the model was assessed using decision curve analysis and clinical impact curve. RESULTS: Among the 381 patients, 199 patients (52.2%) experienced postoperative PMV. The predictive model exhibited good discriminative ability (area under the curve = 0.827, 95% confidence interval: 0.786-0.868, P < 0.05). The calibration curve confirmed that the predicted outcomes of the model closely approximated the ideal curve, indicating agreement between the predicted and actual results (with an average absolute error of 0.01 based on 1000 bootstrap resampling). The decision curve analysis curve demonstrated that the model has significant clinical value. CONCLUSIONS: The nomogram model established in this study can be used to predict the risk of postoperative PMV in patients with AAAD. It serves as a practical tool to assist clinicians in adjusting treatment strategies promptly and implementing targeted therapeutic measures.


Assuntos
Dissecção Aórtica , Respiração Artificial , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Dissecção Aórtica/cirurgia , Nomogramas , Stents/efeitos adversos
7.
J Endovasc Ther ; : 15266028241257106, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38818806

RESUMO

INTRODUCTION: Thoracic endovascular aortic repair (TEVAR) in chronic dissection is associated with a risk for distal stent-graft-induced new entry (dSINE) in up to a quarter of cases. We assess the mid-term outcome of a novel dissection-specific stent-graft (DSSG), which is a custom-made device based on the Cook Alpha platform, with a modified graft design and a distal endovascular elephant trunk without any supporting stent to reduce the radial force on the dissection membrane at the distal landing zone. METHODS: A retrospective single-center study of chronic dissection patients at high risk of dSINE who received an elective endovascular repair with DSSG from January 2017 to June 2023. The primary outcome is Kaplan-Meier (KM) estimated freedom from dSINE during follow-up. Secondary outcomes included technical success, aortic remodeling, and anatomical evaluation of the distal landing zone in cases with dSINE during follow-up versus those without. RESULTS: Thirty patients (24 males) with a median age of 66 years [range=31-78] underwent elective TEVAR with the DSSG. The majority, n=27 (90%), had previous aortic repair; 7 (23%) had established connective tissue disease, and 6 (20%) had established dSINE after previous stent-graft implantation as an indication for TEVAR. Technical success was achieved in n=29 (97%). Median follow-up was 38.5 months (4.3-76.4), and KM estimated freedom from dSINE at 1 and 3 years was 95.6% (SE 0.043) and 89% (SE 0.081), respectively Four cases developed dSINE during follow-up. The median distance from the distal stent-graft to the coeliac trunk was 74mm (range=18-123) in the dSINE group versus 26mm (range=0-74) in the non-dSINE group (p=0.049). Median proximal tangential aortic angulation in the distal landing zone was 38.5° (range=26°-50°) in the dSINE group compared to 21° (range=3-61°) in the non-dSINE group (p=0.052). CONCLUSIONS: The Use of a novel DSSG with low radial force for TEVAR in the setting of chronic dissection is safe and feasible, with remodeling outcomes comparable with standard TEVAR. The reduced distal radial force in the DSSG does not eliminate the risk for dSINE over time, with new entries occurring, particularly in cases where the distal landing zone is in a tortuous aortic segment and not close to the coeliac trunk. CLINICAL IMPACT: Using the novel dissection-specific stent-graft with reduced radial force is safe and feasible but does not completely eliminate the risk of dSINE occurring over time. The exact positioning of the distal stent-graft in a straight aortic segment, close to the coeliac trunk, may be of importance to further mitigate the risk.

8.
J Endovasc Ther ; : 15266028241258401, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38898697

RESUMO

INTRODUCTION: The treatment of acute type B aortic dissection (ATBAD) is currently a challenge for vascular surgeons, because of the early morbidity and mortality rates and the high risk of late aortic events up to 50% at 5 years. This study presents the initial outcomes of ATBAD treatment using optimal medical therapy alone or combined with proximal entry tear stent-graft coverage. Additionally, it provides an analysis of the evolution of the aortic diameter and its clinical consequences during the chronic phase in each group. MATERIALS AND METHODS: Conducted as a retrospective, single-center study, we enrolled all consecutive ATBAD patients (n=130) treated between 2008 and 2020. The primary analysis studies the entire patient cohort based on their initial management approach, namely, medical treatment alone for uncomplicated ATBAD (n=67) or combined with stent-graft entry tear coverage (n=63). We also conducted a subgroup analysis to investigate factors associated with disease progression in the medical management group. RESULTS: Median follow-up was 29.5 months. During this time aneurysmal evolution was observed in: 42.4% of cases in the medical group compared with 21.8% in the stent-graft group, primarily affecting the thoracic aorta. The stent-graft group exhibited significant aortic remodeling, with a decrease in false lumen (FL) and thoracic aortic diameters. Initial aortic diameter ≥40 mm and FL ≥22 mm were independent risk factors for aneurysmal degeneration. Five-year survival was consistent at 76.1% in both groups. CONCLUSION: This study confirms the safety and efficacy of stent-graft entry tear coverage for ATBAD. Initial thoracic endovascular aortic repair (TEVAR) appears to reduce late aortic events by promoting aortic remodeling. Considering TEVAR's safety and potential to prevent late aortic complications, it may be considered for uncomplicated ATBAD patients with an initial aortic diameter ≥40 mm or an FL ≥22 mm. CLINICAL IMPACT: This study validates the efficacy and safety of using endovascular stent grafts to seal the proximal entry tear in cases of acute type B aortic dissections, compared to optimal medical therapy. Aortic remodelling significantly benefits from endovascular stent graft coverage of the proximal entry tear. Given the heightened risk of late aortic events observed in the medical therapy cohort, there appears to be a necessity for including endovascular interventions in the management of uncomplicated acute type B aortic dissections, particularly when aortic diameter is ≥40 mm and false lumen diameter is ≥22 mm.

9.
J Endovasc Ther ; : 15266028241251985, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38708984

RESUMO

PURPOSE: The treatment of thoracoabdominal aortic aneurysms (TAAAs) using branched endovascular aortic repair (BEVAR) is safe and effective. During deployment, the superior mesenteric artery (SMA) branch can unintentionally open into the celiac trunk (CT) ostium and switched catheterization of the SMA from the CT branch and the CT from the SMA branch can be used as an alternative technique in these cases. This study aimed to investigate the outcome of exchanging the intended target vessels (TVs) for the CT and SMA branches during BEVAR. MATERIALS AND METHODS: A single-center retrospective analysis of patients with TAAAs who underwent BEVAR, using off-the-shelf or custom-made devices (CMDs), with an unintended exchange of TVs for the CT and SMA branches was performed. RESULTS: Between 2014 and 2023, 397 patients were treated with BEVAR for TAAA. Eighteen (4.5%) of those patients were treated with an exchange of TVs for the CT and SMA branches. T-branch was used in 9 cases (50%) and the remaining patients were treated with CMDs. Twelve patients were treated electively, 3 were symptomatic and 3 presented with rupture. Of 36 mesenteric TVs in those 18 patients, 34 (94%) were catheterized successfully, including all 18 SMAs and 16 of the 18 CTs. No branch stenosis or occlusion of the switched mesenteric TVs was detected during follow-up. During 30-day follow-up, 3 patients died and during a median follow-up of 3 (interquartile range [IQR]: 1-15) months 3 more patients died. None of the deaths or the 2 unintended reinterventions was induced by the mesenteric TV exchange. The median hospital stay was 14 (IQR: 9-22) days with a median of 4 (IQR: 2-11) days at the intensive care unit. CONCLUSION: The exchange of the mesenteric TVs for the CT and SMA branches during BEVAR with off-the-shelf and CMD endografts is feasible with good TV patency and freedom from TV-related reinterventions. This alternative technique should be considered in selected cases when direct catheterization via the intended branch is deemed more time-consuming or not feasible. CLINICAL IMPACT: This is the first description of using an exchange of target vessels for the celiac trunk and the superior mesenteric artery branches in patients with thoracoabdominal aortic aneurysms undergoing BEVAR, using off-the-shelf or custom-made devices. The high success rate as well as the good clinical results without any branch stenosis or occlusion during follow-up highlight the feasibility of this alternative technique. It could help in challenging cases when catheterization of the intended target vessels is not possible or too time consuming, resulting in higher success rates of BEVAR and better clinical results.

10.
J Endovasc Ther ; : 15266028241270861, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-39188184

RESUMO

PURPOSE: Endovascular aortic repair (EVAR) is currently expanding its feasibility thanks to design innovations, but hostile proximal necks and narrow iliac arteries are still a constraint, as expressed by the Instructions for Use (IFU) of most devices. Our aim is to report the preliminary results of the E-Tegra endograft in infrarenal abdominal aortic aneurysms (AAAs) performed in 15 high-volume centers. MATERIALS AND METHODS: The e-Tegra Italian endoGraft REgistry (TIGRE) is a prospectively maintained database of consecutive EVAR with the E-Tegra stent-graft across 15 participating centers between March 2021 and March 2023. The registry records baseline clinical data, anatomic measurements of the abdominal aorta, perioperative and postoperative outcomes, with a scheduled follow-up period of 3 years for all patients. This is a preliminary analysis of the first results updated to January 2024. The primary endpoints are technical and clinical success, perioperative mortality, freedom from endograft rupture, and aortic-related mortality. The secondary endpoints are freedom from reintervention, and any type of endoleak (EL). The results were analyzed in relation with the anatomic characteristics of the AAAs, namely, iliac axes tortuosity and proximal neck hostility. RESULTS: The registry included 147 consecutive EVAR (138 elective and 9 in emergent setting), 7 of which were associated with an iliac branch implantation. Ninety patients had at least 1 criterion of anatomical hostility, and 25 were treated outside the device IFU. Primary technical success was achieved in 146 cases (99.3%) and assisted success in 147 (100%), with no perioperative mortality. After a median follow-up period of 20 months, no aneurysm-related mortality occurred. Reinterventions were 5: 2 for type IB EL and 3 for type II ELs with aneurysm sac increase. Five more type II ELs with aneurysm sac stability are under observation. No differences in terms of reinterventions were noted between aneurysms with standard and hostile anatomy. CONCLUSION: The E-Tegra endograft is safe and effective in treating AAAs with standard and hostile anatomy, with a low rate of complications and reinterventions, although longer-term outcomes and larger numbers are needed to compare its performances related to specific anatomic criteria. CLINICAL IMPACT: This multi-center nationwide Registry reports a real-world experience of EVAR performed with the E-Tegra abdominal endograft across 15 high-volume Centers, providing early- and mid-term device-specific results, which will help vascular surgeons in endograft selection. In particular, this study focuses on clinical results obtained in treating aneurysms with hostile anatomy, analyzing the performances of the E-Tegra endograft in cases of hostile proximal necks and narrow or tortuous iliac axes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA