Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Molecules ; 27(3)2022 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-35164211

RESUMO

Ambient ionization mass spectrometry has become one of the most promising approaches for rapid and high-throughput screening of small molecules in complex biological matrices for emergency medicine, forensics, and food and agriculture applications. The simple procedures for sample collection and ionization without additional pretreatment are vital in these fields. Many efforts have been devoted to modifying various ambient ionization techniques to simplify the procedures and improve the robustness and sensitivity of the methods. Here, we demonstrate the implementation of rigid spherical sampler probes to improve the robustness of touch spray ionization mass spectrometry. The sphericity of the probes increases the stability of the cone-jet mode of electrospray, reduces the requirements for fine positioning of a sampler in the ion source, and decreases the possibility of corona discharge occurrence. The utilization of spherical sampler probes allows fast, non-invasive sampling, followed by rapid analysis for various drugs of different chemical classes in complex biological matrices, such as the whole blood or sebum collected from the skin surface. The linearity of the analytical signal response from drug concentration confirms the possibility of creating a simple semiquantitative method for small molecules monitoring using spherical sampler probes.


Assuntos
Ensaios de Triagem em Larga Escala/métodos , Preparações Farmacêuticas/análise , Manejo de Espécimes/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Humanos
2.
Anal Bioanal Chem ; 408(20): 5407-14, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27206411

RESUMO

Touch spray-mass spectrometry (TS-MS) is an ambient ionization technique (ionization of unprocessed samples in the open air) that may find intraoperative applications in quickly identifying the disease state of cancerous tissues and in defining surgical margins. In this study, TS-MS was performed on fresh kidney tissue (∼1-5 cm(3)), within 1 h of resection, from 21 human subjects afflicted by renal cell carcinoma (RCC). The preliminary diagnostic value of TS-MS data taken from freshly resected tissue was evaluated. Principal component analysis (PCA) of the negative ion mode (m/z 700-1000) data provided the separation between RCC (16 samples) and healthy renal tissue (13 samples). Linear discriminant analysis (LDA) on the PCA-compressed data estimated sensitivity (true positive rate) and specificity (true negative rate) of 98 and 95 %, respectively, based on histopathological evaluation. The results indicate that TS-MS might provide rapid diagnostic information in spite of the complexity of unprocessed kidney tissue and the presence of interferences such as urine and blood. Desorption electrospray ionization-MS imaging (DESI-MSI) in the negative ionization mode was performed on the tissue specimens after TS-MS analysis as a reference method. The DESI imaging experiments provided phospholipid profiles (m/z 700-1000) that also separated RCC and healthy tissue in the PCA space, with PCA-LDA sensitivity and specificity of 100 and 89 %, respectively. The TS and DESI loading plots indicated that different ions contributed most to the separation of RCC from healthy renal tissue (m/z 794 [PC 34:1 + Cl](-) and 844 [PC 38:4 + Cl](-) for TS vs. m/z 788 [PS 36:1 - H](-) and 810 [PS 38:4 - H](-) for DESI), while m/z 885 ([PI 38:4 - H](-)) was important in both TS and DESI. The prospect, remaining hurdles, and future work required for translating TS-MS into a method of intraoperative tissue diagnosis are discussed. Graphical abstract Touch spray-mass spectrometry used for lipid profiling of fresh human renal cell carcinoma. Left) Photograph of the touch spray probe pointed at the MS inlet. Right) Average mass spectra of healthy renal tissue (blue) and RCC (red).


Assuntos
Biomarcadores Tumorais/análise , Carcinoma de Células Renais/química , Carcinoma de Células Renais/patologia , Neoplasias Renais/química , Rim/química , Fosfolipídeos/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , Algoritmos , Carcinoma de Células Renais/cirurgia , Diagnóstico Diferencial , Humanos , Rim/patologia , Rim/cirurgia , Neoplasias Renais/patologia , Neoplasias Renais/cirurgia , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Células Tumorais Cultivadas
3.
Bladder Cancer ; 4(3): 283-291, 2018 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-30112439

RESUMO

BACKGROUND: In early work ambient ionization mass spectrometry (MS) revealed lipid patterns distinguishing muscle invasive bladder cancer (invasive urothelial carcinoma, InvUC) from normal urothelium. A new ambient ionization MS approach, touch spray MS (TS-MS) can rapidly generate mass spectra in real time, potentially in a point-of-care setting. A tissue sample removed from a patient is touched by a probe, and mass spectra generated within seconds. OBJECTIVE: To validate TS-MS methods using specimens from naturally-occurring InvUC in dogs where the cancer closely mimics the human condition, and to demonstrate proof-of-concept that TS-MS can elucidate lipid patterns distinguishing InvUC from normal urothelium. METHODS: Samples of normal urothelium and InvUC from dogs of several breeds were analyzed by TS-MS with correlative histopathology across each sample. Results were compared to those obtained with desorption electrospray ionization mass spectrometry (DESI-MS), a more traditional method. Data were analyzed by Principal Component Analysis and Linear Discriminant Analysis. RESULTS: Lipid patterns identified by TS-MS, as well as by DESI-MS, differed between InvUC and normal urothelium with m/z 281.5 (oleic acid) and m/z 563.5 (oleic acid dimer) substantially contributing to the differences. Using histologic diagnosis as the gold standard, TS-MS had a global prediction rate of 93%. CONCLUSIONS: TS-MS can be used to identify lipid patterns that differentiate canine InvUC from normal urothelium. Optimization of TS-MS could lead to a point-of-care approach to distinguish cancer from normal in ex vivo tissues in real time, and to define biochemical processes leading to cancer development and progression.

4.
J Mass Spectrom ; 51(12): 1237-1242, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27723220

RESUMO

Newborn screening is one of public health concerns designed to screen infants shortly after birth. Prenatal exposure to tobacco smoke such as nicotine has been reported to affect babies. Levels of nicotine and cotinine in meconium were widely used to evaluate the tobacco exposure of foetuses during pregnancy in a polluted environment. In this study, medical swabs were applied by using touch spray-mass spectrometry (TS-MS) to collect meconium from newborn infants for detection of nicotine and cotinine. Parameters such as choice of spray solvents, solvent volume and collision energy for screening of nicotine and cotinine were optimized. The limits of detection, reproducibility and matrix effect for analysis of meconium were also investigated. In this study, the levels of nicotine and cotinine in 54 puerpera volunteers were screened by TS-MS and were validated by using traditional liquid chromatography-mass spectrometry. These results showed that medical swab TS-MS would be useful for newborn screening of nicotine and cotinine in meconium with high reproducibility, speed, sensitivity and specificity. The use of disposable medical swabs involves no sample preparation and no chromatographic separation, significantly reducing the cost and time required for screening a large number of clinical sample. Copyright © 2016 John Wiley & Sons, Ltd.


Assuntos
Cotinina/análise , Mecônio/química , Triagem Neonatal/métodos , Nicotina/análise , Espectrometria de Massas em Tandem/métodos , Feminino , Humanos , Recém-Nascido , Limite de Detecção , Modelos Lineares , Gravidez , Reprodutibilidade dos Testes
5.
Anal Chim Acta ; 861: 47-54, 2015 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-25702273

RESUMO

Fourteen common drugs of abuse were identified in spiked oral fluid (ng mL(-1) levels), analyzed directly from medical swabs using touch spray mass spectrometry (TS-MS), exemplifying a rapid test for drug detection. Multiple stages of mass analysis (MS(2) and MS(3)) provided identification and detection limits sought by international forensic and toxicological societies, Δ(9)-THC and buprenorphine excluded. The measurements were made using a medical swab as both the sampling probe and means of ionization. The adaptation of medical swabs for TS-MS analysis allows non-invasive and direct sampling of neat oral fluid. Data acquisition was rapid, seconds per drug, and MS(3) ensured reliable identification of illicit drugs. The reported data were acquired to investigate (i) ionization of common drugs from commercial swabs, (ii) ion intensity over spray duration, and (iii) dynamic range, all as initial steps in development of a quantitative method. The approach outlined is intended for point-of-care drug testing using oral fluid in clinical applications as well as in situ settings, viz. in forensic applications. The proof-of-concept results presented will require extension to other controlled substances and refinement in analytical procedures to meet clinical/legal requirements.


Assuntos
Espectrometria de Massas/métodos , Preparações Farmacêuticas/análise , Saliva/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA