Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 696
Filtrar
Mais filtros

País/Região como assunto
Intervalo de ano de publicação
1.
Strahlenther Onkol ; 2024 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-39060636

RESUMO

BACKGROUND: The effective dose to circulating immune cells (EDIC) is associated with survival in lung and esophageal cancer patients. This study aimed to evaluate the benefit of intensity-modulated proton therapy (IMPT) for EDIC reduction as compared to volumetric modulated arc therapy (VMAT) in patients with locally advanced breast cancer (BC). MATERIALS AND METHODS: Ten BC patients treated with locoregional VMAT after breast-conserving surgery were included. Mean dose to the heart (MHD), lungs (MLD), and liver (MlD), as well as the integral dose to the body (ITD), were retrieved, and we calculated EDIC as 0.12â€¯× MLD + 0.08â€¯× MHD + 0.15â€¯× 0.85â€¯× âˆš(n/45)â€¯× MlD + (0.45 + 0.35â€¯× 0.85â€¯× âˆš(n/45))â€¯× ITD/(62â€¯× 103), where n is the number of fractions. EDIC was compared between VMAT and IMPT plans. RESULTS: Median EDIC was reduced from 3.37 Gy (range: 2.53-5.99) with VMAT to 2.13 Gy (1.31-3.77) with IMPT (p < 0.01). For left-sided BC patients, EDIC was reduced from 3.15 Gy (2.53-3.78) with VMAT to 1.65 Gy (1.31-3.77) with IMPT (p < 0.01). For right-sided BC patients, EDIC was reduced from 5.60 Gy (5.06-5.99) with VMAT to 3.38 Gy (3.10-3.77) with IMPT (p < 0.01). Right-sided BC patients had a higher EDIC irrespective of the technique. Integral dose reduction was the main driver of EDIC reduction with IMPT and was associated with lung sparing for left-sided BC patients or liver sparing for right-sided BC patients. CONCLUSION: IMPT significantly reduced EDIC in BC patients undergoing locoregional adjuvant radiotherapy. Integral total dose reduction, associated with improved lung sparing in left-sided BC patients or liver sparing in right-sided BC patients, mainly drove EDIC reduction with IMPT. The emergence of dynamic models taking into account the circulatory kinetics of immune cells may improve the accuracy of the estimate of the dose received by the immune system compared to calculation of the EDIC, which is based solely on static dosimetric data.

2.
Strahlenther Onkol ; 200(3): 219-229, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37707518

RESUMO

BACKGROUND: A simultaneous integrated boost (SIB) may result in increased out-of-field (DOOF) and photoneutron (HPN) doses in volumetric modulated arc therapy (VMAT) for prostate cancer (PCA). This work therefore aimed to compare DOOF and HPN in flattened (FLAT) and flattening filter-free (FFF) 6­MV and 10-MV VMAT treatment plans with and without SIB. METHODS: Eight groups of 30 VMAT plans for PCA with 6 MV or 10 MV, with or without FF and with uniform (2 Gy) or SIB target dose (2.5/3.0 Gy) prescriptions (CONV, SIB), were generated. All 240 plans were delivered on a slab-phantom and compared with respect to measured DOOF and HPN in 61.8 cm distance from the isocenter. The 6­ and 10-MV flattened VMAT plans with conventional fractionation (6- and 10-MV FLAT CONV) served as standard reference groups. Doses were analyzed as a function of delivered monitor units (MU) and weighted equivalent square field size Aeq. Pearson's correlation coefficients between the presented quantities were determined. RESULTS: The SIB plans resulted in decreased HPN over an entire prostate RT treatment course (10-MV SIB vs. CONV -38.2%). Omission of the flattening filter yielded less HPN (10-MV CONV -17.2%; 10-MV SIB -22.5%). The SIB decreased DOOF likewise by 39% for all given scenarios, while the FFF mode reduced DOOF on average by 60%. A strong Pearson correlation was found between MU and HPN (r > 0.9) as well as DOOF (0.7 < r < 0.9). CONCLUSION: For a complete treatment, SIB reduces both photoneutron and OOF doses to almost the same extent as FFF deliveries. It is recommended to apply moderately hypofractionated 6­MV SIB FFF-VMAT when considering photoneutron or OOF doses.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias da Próstata/radioterapia , Fracionamento da Dose de Radiação , Próstata , Dosagem Radioterapêutica
3.
Strahlenther Onkol ; 200(8): 676-683, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38180494

RESUMO

BACKGROUND: Although robot-assisted radical prostatectomy (RARP) and intensity-modulated radiotherapy are the leading respective techniques of prostatectomy and radiotherapy for localized prostate cancer, almost no study has directly compared their outcomes; none have compared mortality outcomes. METHODS: We compared 6­year outcomes of RARP (n = 500) and volumetric modulated arc therapy (VMAT, a rotational intensity-modulated radiotherapy, n = 360) in patients with cT1-4N0M0 prostate cancer. We assessed oncological outcomes, namely overall survival (OS), cancer-specific survival (CSS), radiological recurrence-free survival (rRFS), and biochemical recurrence-free survival (bRFS), using propensity score matching (PSM). We also assessed treatment-related complication outcomes of prostatectomy and radiotherapy. RESULTS: The median follow-up duration was 79 months (> 6 years). PSM generated a matched cohort of 260 patients (130 per treatment group). In the matched cohort, RARP and VMAT showed equivalent results for OS, CSS, and rRFS: both achieved excellent 6­year outcomes for OS (> 96%), CSS (> 98%), and rRFS (> 91%). VMAT had significantly longer bRFS than RARP, albeit based on different definitions of biochemical recurrence. Regarding complication outcomes, patients who underwent RARP had minimal (2.6%) severe perioperative complications and achieved excellent continence recovery (91.6 and 68.8% of the patients achieved ≤ 1 pad/day and pad-free, respectively). Patients who underwent VMAT had an acceptable rate (20.0%) of grade ≥ 2 genitourinary complications and a very low rate (4.4%) of grade ≥ 2 gastrointestinal complications. CONCLUSION: On the basis of PSM after a 6-year follow-up, RARP and VMAT showed equivalent and excellent oncological outcomes, as well as acceptable complication profiles.


Assuntos
Pontuação de Propensão , Prostatectomia , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Procedimentos Cirúrgicos Robóticos , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Neoplasias da Próstata/patologia , Neoplasias da Próstata/mortalidade , Radioterapia de Intensidade Modulada/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Estadiamento de Neoplasias , Seguimentos , Taxa de Sobrevida , Intervalo Livre de Doença
4.
Artigo em Inglês | MEDLINE | ID: mdl-38762614

RESUMO

Modern radiotherapy machines offer a new modality, like flattening filter-free beam (FFF), which is used especially in stereotactic body radiation therapy (SBRT) to reduce treatment time. The remaining volume at risk (RVR) is known as undefined normal tissue, and assists in evaluating late effects such as carcinogenesis. This study aimed to compare the effects of flattening and un-flattened beams on RVR in lung cancer treated by conventional doses using volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT). Twenty-three lung cancer patients with a prescribed dose of 60 Gy delivered in 30 fractions were selected retrospectively. Four treatment plans were generated for each case (VMAT FF, VMAT FFF, IMRT FF and IMRT FFF). Mean doses to RVR and volumes that received low doses (V15Gy, V10Gy and V5Gy) were introduced as RVR evaluation parameters. Variance percentage comparison between flattening filter (FF) and FFF for the RVR evaluation parameters gave 2.38, 1.10, 1.80 and 2.22 for VMAT, and 1.73, 1.18, 1.62 and 1.81 for IMRT. In contrast, VMAT and IMRT RVR evaluation parameters resulted in variance percentage differences of 10.29, 5.02, - 8.84 and - 4.82 for FF, and 11.18, 4.96, - 8.59 and - 4.48for FFF. It is concluded that in terms of RVR evaluation parameters, FFF is clinically beneficial compared to FF for RVR, due to the decrease in mean RVR dose and low-dose irradiated RVR volume. Furthermore, VMAT is preferred in the mean RVR dose and V15Gy, while IMRT is better in V10Gy and V5Gy for RVR.

5.
J Appl Clin Med Phys ; 25(1): e14215, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37987544

RESUMO

PURPOSE: We sought to develop machine learning models to predict the results of patient-specific quality assurance (QA) for volumetric modulated arc therapy (VMAT), which were represented by several dose-evaluation metrics-including the gamma passing rates (GPRs)-and criteria based on the radiomic features of 3D dose distribution in a phantom. METHODS: A total of 4,250 radiomic features of 3D dose distribution in a cylindrical dummy phantom for 140 arcs from 106 clinical VMAT plans were extracted. We obtained the following dose-evaluation metrics: GPRs with global and local normalization, the dose difference (DD) in 1% and 2% passing rates (DD1% and DD2%) for 10% and 50% dose threshold, and the distance-to-agreement in 1-mm and 2-mm passing rates (DTA1 mm and DTA2 mm) for 0.5%/mm and 1.0%.mm dose gradient threshold determined by measurement using a diode array in patient-specific QA. The machine learning regression models for predicting the values of the dose-evaluation metrics using the radiomic features were developed based on the elastic net (EN) and extra trees (ET) models. The feature selection and tuning of hyperparameters were performed with nested cross-validation in which four-fold cross-validation is used within the inner loop, and the performance of each model was evaluated in terms of the root mean square error (RMSE), the mean absolute error (MAE), and Spearman's rank correlation coefficient. RESULTS: The RMSE and MAE for the developed machine learning models ranged from <1% to nearly <10% depending on the dose-evaluation metric, the criteria, and dose and dose gradient thresholds used for both machine learning models. It was advantageous to focus on high dose region for predicating global GPR, DDs, and DTAs. For certain metrics and criteria, it was possible to create models applicable for patients' heterogeneity by training only with dose distributions in phantom. CONCLUSIONS: The developed machine learning models showed high performance for predicting dose-evaluation metrics especially for high dose region depending on the metric and criteria. Our results demonstrate that the radiomic features of dose distribution can be considered good indicators of the plan complexity and useful in predicting measured dose evaluation metrics.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiômica , Aprendizado de Máquina , Raios gama , Dosagem Radioterapêutica
6.
J Appl Clin Med Phys ; 25(1): e14218, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38013656

RESUMO

OBJECTIVE: This study aimed to discuss the dosimetric advantages of helical tomotherapy (HT) and volumetric modulated arc therapy (VMAT) technology in hippocampal avoidance whole-brain radiotherapy and provide references for clinical selection of ideal radiotherapy technology. METHODS: A total of 20 patients with hippocampal avoidance whole-brain radiotherapy were chosen randomly. Computed tomography (CT) and MRI scanning images were input into the treatment planning system (TPS). After the CT and enhanced magnetic resonance T1 weighted images were fused and registered, the same radiation therapy physician was invited to outline the tumor target volume. PTV-HS refers to the whole brain subtracted by 5 mm outward expansion of the hippocampus (HP). The prescribed dose was 30 Gy/10 fractions. HT and VMAT plans were designed for each patient in accordance with PTV. Under the premise that the 95% isodose curve covers the PTV, dose-volume histogram was applied to evaluate the PTV, conformal index (CI), heterogeneity index (HI), maximum dose (Dmax), mean dose (Dmean), minimum dose (Dmin) and absorbed doses of organs at risk (OARs) in HT and VMAT plans. Paired t-test was performed to compare the differences between two radiation therapy plans, and p  <  0.05 was considered statistically significant. RESULTS: These two plans had no significant difference in PTV-HS (max, min, and mean). However, the HI and CI of the HT plan were significantly better than those of the VMAT plan, showing statistically significant difference (p < 0.05). The HT plan was significantly superior to the VMAT plan in terms of the Dmax, Dmin, and Dmean of HP, left and right eye lens, left and right eye, and spinal cord, showing statistically significant difference (p < 0.05). The HT plan was also better than the VMAT plan in terms of the Dmax of the left optic nerve. However, the two plans showed no obvious differences in terms of the absorbed doses of the right optic nerve and brainstem, without statistical significance. CONCLUSIONS: Compared with the VMAT plan of hippocampal avoidance, HT technology has significant dosimetric advantages. HT plans significantly decreased the radiation dose and radiation volume of OARs surrounding the target area (e.g., surrounding eye lens and eye, especially hippocampal avoidance area) while increasing the CI and HI of PTV dose in whole brain radiotherapy (WBRT) greatly, thus enabling the decrease in the incidence rate of radioactive nerve function impairment.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Encéfalo , Hipocampo
7.
J Appl Clin Med Phys ; 25(8): e14365, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38760907

RESUMO

PURPOSE: With proper beam setup and optimization constraints in the treatment planning system, volumetric modulated arc therapy (VMAT) can improve target dose coverage and conformity while reducing doses to adjacent structures for whole breast radiation therapy. However, the low-dose bath effect on critical structures, especially the heart and the ipsilateral lung, remains a concern. In this study, we present a VMAT technique with the jaw offset VMAT (JO-VMAT) to reduce the leakage and scatter doses to critical structures for whole breast radiation therapy. MATERIALS AND METHODS: The data of 10 left breast cancer patients were retrospectively used for this study. CT images were acquired on a CT scanner (GE, Discovery) with the deep-inspiration breath hold (DIBH) technique. The planning target volumes (PTVs) and the normal structures (the lungs, the heart, and the contralateral breast) were contoured on the DIBH scan. A 3D field-in-field plan (3D-FiF), a tangential VMAT (tVMAT) plan, and a JO-VMAT plan were created with the Eclipse treatment planning system. An arc treatment field with the x-jaw closed across the central axis creates a donut-shaped high-dose distribution and a cylinder-shaped low-dose volume along the central axis of gantry rotation. Applying this setup with proper multi-leaf collimator (MLC) modulation, the optimized plan potentially can provide sufficient target coverage and reduce unnecessary irradiation to critical structures. The JO-VMAT plans involve 5-6 tangential arcs (3 clockwise arcs and 2-3 counterclockwise arcs) with jaw offsets. The plans were optimized with objective functions specified to achieve PTV dose coverage and homogeneity; For organs at risk (OARs), objective functions were specified individually for each patient to accomplish the best achievable treatment plan. For tVMAT plans, optimization constraints were kept the same except that the jaw offset was removed from the initial beam setup. The dose volume histogram (DVH) parameters were generated for dosimetric evaluation of PTV and OARs. RESULTS: The D95% to the PTV was greater than the prescription dose of 42.56 Gy for all the plans. With both VMAT techniques, the PTV conformity index (CI) was statistically improved from 0.62 (3D-FiF) to 0.83 for tVMAT and 0.84 for JO-VMAT plans. The difference in the homogeneity index (HI) was not significant. The Dmax to the heart was reduced from 12.15 Gy for 3D-FiF to 8.26 Gy for tVMAT and 7.20 Gy for JO-VMAT plans. However, a low-dose bath effect was observed with tVMAT plans to all the critical structures including the lungs, the heart, and the contralateral breast. With JO-VMAT, the V5Gy and V2Gy of the heart were reduced by 32.7% and 15.4% compared to 3D-FiF plans. Significantly, the ipsilateral lung showed a reduction in mean dose (4.65-3.44 Gy) and low dose parameters (23.4% reduction for V5Gy and 10.7% reduction for V2Gy) for JO-VMAT plans compared to the 3D-FiF plans. The V2Gy dose to the contralateral lung and breast was minimal with JO-VMAT techniques. CONCLUSION: A JO-VMAT technique was evaluated in this study and compared with 3D-FiF and tVMAT techniques. Our results showed that the JO-VMAT technique can achieve clinically comparable coverage and homogeneity and significantly improve dose conformity within PTV. Additionally, JO-VMAT eliminated the low-dose bath effect at all OARs evaluation metrics including the ipsilateral/contralateral lung, the heart, and the contralateral breast compared to 3D-FiF and tVMAT. This technique is feasible for the whole breast radiation therapy of left breast cancers.


Assuntos
Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Feminino , Estudos Retrospectivos , Neoplasias da Mama/radioterapia , Neoplasias Unilaterais da Mama/radioterapia , Tomografia Computadorizada por Raios X/métodos , Coração/efeitos da radiação
8.
J Appl Clin Med Phys ; : e14437, 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-39031794

RESUMO

PURPOSE: The positional accuracy of MLC is an important element in establishing the exact dosimetry in VMAT. We comprehensively analyzed factors that may affect MLC positional accuracy in VMAT, and constructed a model to predict MLC positional deviation and estimate planning delivery quality according to the VMAT plans before delivery. METHODS: A total of 744 "dynalog" files for 23 VMAT plans were extracted randomly from treatment database. Multi-correlation was used to analyzed the potential influences on MLC positional accuracy, including the spatial characteristics and temporal variability of VMAT fluence, and the mechanical wear parameters of MLC. We developed a model to forecast the accuracy of MLC moving position utilizing the random forest (RF) ensemble learning method. Spearman correlation was used to further investigate the associations between MLC positional deviation and dosage deviations as well as gamma passing rates. RESULTS: The MLC positional deviation and effective impact factors show a strong multi-correlation (R = 0.701, p-value < 0.05). This leads to the development of a highly accurate prediction model with average variables explained of 95.03% and average MSE of 0.059 in the 5-fold cross-validation, and MSE of 0.074 for the test data was obtained. The absolute dose deviations caused by MLC positional deviation ranging from 12.948 to 210.235 cGy, while the relative volume deviation remained small at 0.470%-5.161%. The average MLC positional deviation correlated substantially with gamma passing rates (with correlation coefficient of -0.506 to -0.720 and p-value < 0.05) but marginally with dosage deviations (with correlation coefficient < 0.498 and p-value > 0.05). CONCLUSIONS: The RF predictive model provides a prior tool for VMAT quality assurance.

9.
J Appl Clin Med Phys ; : e14479, 2024 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-39032169

RESUMO

PURPOSE: This study aims to introduce modified fixed field volumetric modulated arc therapy (MF-VMAT) which manually opened the field size by fixing the jaws and comparing it to the typical planning technique, auto field volumetric modulated arc therapy (AF-VMAT) in cervical cancer treatment planning. METHODS AND MATERIALS: Previously treated twenty-eight cervical cancer plans were retrospectively randomly selected and replanned in this study using two different planning techniques: AF-VMAT and MF-VMAT, resulting in a total of fifty-six treatment plans. In this study, we compared both planning techniques in three parts: (1) Organ at Risk (OARs) and whole-body dose, (2) Treatment plan efficiency, and (3) Treatment plan accuracy. RESULTS: For OARs dose, bowel bag (p-value = 0.001), rectum (p-value = 0.002), and left femoral head (p-value = 0.001) and whole-body (p-value = 0.000) received a statistically significant dose reduction when using the MF-VMAT plan. Regarding plan efficiency, MF-VMAT exhibited a statistically significant increase in both number of monitor units (MUs) and control points (p-values = 0.000), while beam-on time, maximum leaf travel, average maximum leaf travel, and maximum leaf travel per gantry rotation were statistically significant decreased (p-values = 0.000). In terms of plan accuracy, the average gamma passing rate was higher in the MF-VMAT plan for both absolute dose (AD) (p-value = 0.001, 0.004) and relative dose (RD) (p-value = 0.000, 0.000) for 3%/3 and 3%/2 mm gamma criteria, respectively. CONCLUSION: The MF-VMAT planning technique significantly reduces OAR doses and decreases the spread of low doses to normal tissues in cervical cancer patients. Additionally, this planning approach demonstrates efficient plans with lower beam-on time and reduced maximum leaf travel. Furthermore, it indicates higher plan accuracy through an increase in the average gamma passing rate compared to the AF-VMAT plan. Consequently, MF-VMAT offers an effective treatment planning technique for cervical cancer patients.

10.
J Appl Clin Med Phys ; : e14409, 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38923699

RESUMO

BACKGROUND: To investigate the effect of the Increment of gantry angle (Inc) parameter setting of the Monaco Treatment planning system (Monaco TPS) on the dosimetry and quality parameters of the volumetric modulated arc therapy (VMAT) program for rectal cancer. METHODS: A retrospective analysis was conducted on 50 patients with rectal cancer who underwent intensity modulated radiation therapy using the Monaco TPS system from 2020 to 2021. Under the same optimization function configuration and other parameter settings, the Inc parameters in the VMAT radiotherapy plan were set to 10°, 20°, 30°, and 40°. The dose-volume histogram (DVH) was used to evaluate the dose distribution of the target area and the radiation dose of the organs at risk (OAR). The differences in the dosimetry of the planning target volume (PTV) and OAR, as well as the gamma pass rate (GPR) were compared. RESULTS: In terms of target dose, D98, Dmin, HI, and conformity index (CI) of Inc10 group was significantly lower than those of Inc20, 30, and 40 groups (P < 0.05), and D2 of Inc10 group was significantly higher than that of Inc20 group (P = 0.009). We also found CI of Inc20 and 30 were significantly better than that of Inc40 (both P < 0.05). In terms of OAR dose, the study found that the Dmean, Dmin, V50%, V45%, and V40% for the bladder of the Inc10 group were lower than those of the other groups (all P < 0.05), the Dmean for femoral head of the Inc20 group was lower than that of the Inc30 group (P < 0.05), and Inc20 showed a better protective effect on the femoral head. The MUs tend to decrease as the Inc parameter setting is increased. The monitor unit (MU) in Inc10 group were significantly higher than those in Inc20, Inc30, and Inc40 groups, and the MU of Inc20 group was significantly higher than that of Inc40 group (both P < 0.05). We found that for the 3%/3 mm and 2%/2 mm standards, the GPRs of each plan were > 90%, which met clinical requirements. CONCLUSIONS: Different settings of Inc parameters have varying degrees of impact on target dose, OAR dose, and machine MU. It is important for doctors to choose different Inc parameters according to different clinical needs.

11.
J Appl Clin Med Phys ; 25(2): e14189, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37917885

RESUMO

PURPOSE: We performed scalp-avoidance whole-brain irradiation with volumetric-modulated arc therapy (SAWB-VMAT) as a component of craniospinal irradiation. In SAWB-VMAT with two coplanar arcs, radiation oncologists and medical physicists sometimes experience difficulty in reducing the dose to the scalp to below the cut-off equivalent dose in 2 Gy per fraction (assuming α/ß = 2) to 50% (EQD50%scalp ). To investigate the advantage of adding coplanar or non-coplanar arcs in reducing the dose to the scalp in SAWB-VMAT, we conducted a planning study to compare the EQD50%scalp , the dose to other organs at risk (OARs), and target coverage in VMAT with two coplanar arcs (Co2arcVMAT), VMAT with three coplanar arcs (Co3arcVMAT), and VMAT with two coplanar and two non-coplanar arcs (NcVMAT). METHODS: Co2arcVMAT, Co3arcVMAT, and NcVMAT plans were created for 10 pediatric patients with medulloblastoma. The planned target volume (PTV) included the regions of the whole brain, cervical spinal cord, cerebrospinal fluid space, and intervertebral foramen. The EQD50%scalp was evaluated separately for four areas (top, back, left, and right) in each case. The prescribed dose for the PTV was 35.2 Gy in 22 fractions. RESULTS: The median EQD50%scalp of the top area was 21.9 , 22.1 , and 18.3 Gy for Co2arcVMAT, Co3arcVMAT, and NcVMAT, respectively. The EQD50%scalp of the top area was significantly reduced in NcVMAT compared to those in Co2arcVMAT and Co3arcVMAT (p < 0.05). The median EQD50%scalp of the top area for NcVMAT was < 19.9 Gy, which is the cut-off dose for severe permanent alopecia. There were no significant differences in EQD50%scalp in the three other areas, the dose to other OARs, or the dose coverage of PTV among the three techniques. CONCLUSION: NcVMAT could reduce the EQD50%scalp of the top area below the cut-off dose of 19.9 Gy. NcVMAT appears to be a promising treatment technique for SAWB-VMAT.


Assuntos
Neoplasias Cerebelares , Meduloblastoma , Radioterapia de Intensidade Modulada , Humanos , Criança , Meduloblastoma/radioterapia , Meduloblastoma/etiologia , Dosagem Radioterapêutica , Redução da Medicação , Couro Cabeludo , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco/efeitos da radiação , Encéfalo , Neoplasias Cerebelares/etiologia
12.
J Appl Clin Med Phys ; : e14480, 2024 Aug 09.
Artigo em Inglês | MEDLINE | ID: mdl-39120606

RESUMO

OBJECTIVE: This study aims to analyze setup errors in pelvic Volumetric Modulated Arc Therapy (VMAT) for patients with non-surgical primary cervical cancer, utilizing the onboard iterative kV cone beam CT (iCBCT) imaging system on the Varian Halcyon 2.0 ring gantry structure accelerator to enhance radiotherapy precision. METHOD: We selected 132 cervical cancer patients who underwent VMAT with daily iCBCT imaging guidance. Before each treatment session, a registration method based on the bony structure was employed to acquire iCBCT images with the corresponding planning CT images. Following verification and adjustment of image registration results along the three axes (but not rotational), setup errors in the lateral (X-axis), longitudinal (Y-axis), and vertical (Z-axis) directions were recorded for each patient. Subsequently, we analyzed 3642 iCBCT image setup errors. RESULTS: The mean setup errors for the X, Y, and Z axes were 4.50 ± 3.79 mm, 6.08 ± 6.30 mm, and 1.48 ± 2.23 mm, respectively. Before correction with iCBCT, setup margins based on the Van Herk formula for the X, Y, and Z axes were 6.28, 12.52, and 3.26 mm, respectively. In individuals aged 60 years and older, setup errors in the X and Y axes were significantly larger than those in the younger group (p < 0.05). Additionally, there is no significant linear correlation between setup errors and treatment fraction numbers. CONCLUSION: Data analysis underscores the importance of precise Y-axis setup for cervical cancer patients undergoing VMAT. Radiotherapy centers without daily iCBCT should appropriately extend the planning target volume (PTV) along the Y-axis for cervical cancer patients receiving pelvic VMAT. Elderly patients exhibit significantly larger setup errors compared to younger counterparts. In conclusion, iCBCT-guided radiotherapy is recommended for cervical cancer patients undergoing VMAT to improve setup precision.

13.
J Appl Clin Med Phys ; 25(8): e14394, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38887816

RESUMO

PURPOSE: The treatment of brain tumors in pregnant patients poses challenges, as the out-of-field dose exposure to the fetus can potentially be harmful. A pregnant patient with prior radiation treatment was presented with a brain tumor at our clinic. This work reports on our pre-treatment study that compared fetal dose exposure between intensity-modulated proton therapy (IMPT) using pencil beam scanning (PBS) and conventional photon 3D conformal radiation therapy (3DCRT) and volumetric-modulated arc therapy (VMAT), and the subsequent pregnant patient's radiation treatment. MATERIALS AND METHODS: Pre-treatment measurements of clinical plans, 3DCRT, VMAT, and IMPT, were conducted on a phantom. Measurements were performed using a device capable of neutron detections, closely following AAPM guidelines, TG158. For photon measurements, fetus shielding was utilized. On patient treatment days, which was determined to be proton treatment, shielding was used only during daily imaging for patient setup. Additionally, an in vivo measurement was conducted on the patient. RESULTS: Measurements showed that IMPT delivered the lowest fetal dose, considering both photon and neutron out-of-field doses to the fetus, even when shielding was implemented for photon measurements. Additionally, the proton plans demonstrated superior treatment for the mother, a reirradiation case. CONCLUSION: The patient was treated with proton therapy, and the baby was subsequently delivered at full term with no complications. This case study supports previous clinical findings and advocates for the expanded use of proton therapy in this patient population.


Assuntos
Neoplasias Encefálicas , Feto , Órgãos em Risco , Imagens de Fantasmas , Terapia com Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Gravidez , Feminino , Radioterapia de Intensidade Modulada/métodos , Neoplasias Encefálicas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Terapia com Prótons/métodos , Feto/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Radioterapia Conformacional/métodos , Adulto , Complicações Neoplásicas na Gravidez/radioterapia
14.
J Appl Clin Med Phys ; 25(4): e14250, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38146130

RESUMO

BACKGROUND: Organ-at-risk (OAR) sparing is often assessed using an overlap volume-based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap-based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR. PURPOSE: We propose a new overlap-based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap-based predictive parameter (POPP) is evaluated compared with COPP. METHODS: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) × (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto-Planning module of Pinnacle3 treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap-based predictive parameters (COPP and POPP) and dose-volume metrics (mean dose, V70Gy, V60Gy, and V37.5 Gy for rectum and bladder) was investigated using linear regression analysis. RESULTS: Our results indicated POPP was better than COPP in predicting intermediate-dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05). CONCLUSIONS: POPP is superior to COPP for creating predictive models at an intermediate-dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate-doses as well as high-doses, it is important to predict dose-volume metrics for various dose levels. POPP is a useful parameter for predicting dose-volume metrics and assisting the generation of treatment plans.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Neoplasias da Próstata/radioterapia
15.
BMC Med Educ ; 24(1): 463, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38671374

RESUMO

BACKGROUND: Cancer patients are often treated with radiation, therefore increasing their exposure to high energy emissions. In such cases, medical errors may be threatening or fatal, inducing the need to innovate new methods for maximum reduction of irreversible events. Training is an efficient and methodical tool to subject professionals to the real world and heavily educate them on how to perform with minimal errors. An evolving technique for this is Serious Gaming that can fulfill this purpose, especially with the rise of COVID-19 and the shift to the online world, by realistic and visual simulations built to present engaging scenarios. This paper presents the first Serious Game for Lung Cancer Radiotherapy training that embodies Biomedical Engineering principles and clinical experience to create a realistic and precise platform for coherent training. METHODS: To develop the game, thorough 3D modeling, animation, and gaming fundamentals were utilized to represent the whole clinical process of treatment, along with the scores and progress of every player. The model's goal is to output coherency and organization for students' ease of use and progress tracking, and to provide a beneficial educational experience supplementary to the users' training. It aims to also expand their knowledge and use of skills in critical cases where they must perform crucial decision-making and procedures on patients of different cases. RESULTS: At the end of this research, one of the accomplished goals consists of building a realistic model of the different equipment and tools accompanied with the radiotherapy process received by the patient on Maya 2018, including the true beam table, gantry, X-ray tube, CT Scanner, and so on. The serious game itself was then implemented on Unity Scenes with the built models to create a gamified authentic environment that incorporates the 5 main series of steps; Screening, Contouring, External Beam Planning, Plan Evaluation, Treatment, to simulate the practical workflow of an actual Oncology treatment delivery for lung cancer patients. CONCLUSION: This serious game provides an educational and empirical space for training and practice that can be used by students, trainees, and professionals to expand their knowledge and skills in the aim of reducing potential errors.


Assuntos
COVID-19 , Neoplasias Pulmonares , Jogos de Vídeo , Humanos , Neoplasias Pulmonares/radioterapia , Radioterapia (Especialidade)/educação , SARS-CoV-2 , Competência Clínica
16.
J Xray Sci Technol ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39093110

RESUMO

INTRODUCTION: Intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) are the main radiotherapy techniques for treating and managing rectal cancer. Collimator rotation is one of the crucial parameters in radiotherapy planning, and its alteration can cause dosimetric variations. This study assessed the effect of collimator rotation on the dosimetric results of various IMRT and VMAT plans for rectal cancer. MATERIALS AND METHODS: Computed tomography (CT) images of 20 male patients with rectal cancer were utilized for IMRT and VMAT treatment planning with various collimator angles. Nine different IMRT techniques (5, 7, and 9 coplanar fields with collimator angles of 0°, 45°, and 90°) and six different VMAT techniques (1 and 2 full coplanar arcs with collimator angles of 0°, 45°, and 90°) were planned for each patient. The dosimetric results of various treatment techniques for target tissue (conformity index [CI] and homogeneity index [HI]) and organs at risk (OARs) sparing (parameters obtained from OARs dose-volume histograms [DVH]) as well as radiobiological findings were analyzed and compared. RESULTS: The 7-fields IMRT technique demonstrated lower bladder doses (V40Gy, V45Gy), unaffected by collimator rotation. The 9-fields IMRT and 2-arcs VMAT (excluding the 90-degree collimator) had the lowest V35Gy and V45Gy. A 90-degree collimator rotation in 2-arcs VMAT significantly increased small bowel and bladder V45Gy, femoral head doses, and HI values. Radiobiologically, the 90-degree rotation had adverse effects on small bowel NTCP (normal tissue complication probability). No superiority was found for a 45-degree collimator rotation over 0 or 30 degrees in VMAT techniques. CONCLUSION: Collimator rotation had minimal impact on dosimetric parameters in IMRT planning but is significant in VMAT techniques. A 90-degree rotation in VMAT, particularly in a 2-full arc technique, adversely affects PTV homogeneity index, bladder dose, and small bowel NTCP. Other evaluated collimator angles did not significantly affect VMAT dosimetrical or radiobiological outcomes.

17.
Strahlenther Onkol ; 199(1): 90-101, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35943553

RESUMO

PURPOSE: The purpose of this study was to compare two techniques of irradiation of left-sided breast cancer patients who underwent breast-conserving surgery, three-dimensional conformal radiotherapy technique (3D-CRT) and volumetric modulated arc therapy (VMAT), in terms of dose distribution in the planning target volume (PTV) and organs at risk (OARs). The second aim of the study was estimation of the projected risk of radiation-induced secondary cancer for both radiotherapy techniques. MATERIALS AND METHODS: For 25 patients who underwent CT simulation in deep inspiration breath-hold (DIBH), three treatment plans were generated: one using a three-dimensional conformal radiotherapy technique and two using volumetric modulated arc therapy. First VMAT-DIBH geometry consisted of three partial arcs (ARC-DIBH 3A) and second consisted of four partial arcs (ARC-DIBH 4A). Cumulative dose-volume histograms (DVHs) were used to compare dose distributions within the PTV and OARs (heart, left anterior descending coronary artery [LAD], ipsilateral and contralateral lung [IL, CL], and contralateral breast [CB]). Normal tissue complication probabilities (NTCPs) and organ equivalent doses (OEDs) were calculated using the differential DVHs. Excess absolute risks (EARs) for second cancers were estimated using Schneider's full mechanistic dose-response model. RESULTS: All plans fulfilled the criterium for PTV V95% ≥ 95%. The PTV coverage, homogeneity, and conformity indices were significantly better for VMAT-DIBH. VMAT showed a significantly increased mean dose and V5Gy for all OARs, but reduced LAD Dmax by 15 Gy. For IL, CL, and CB, the 3D-CRT DIBH method achieved the lowest values of EAR: 28.38 per 10,000 PYs, 2.55 per 10,000 PYs, and 4.48 per 10,000 PYs (p < 0.001), compared to 40.29 per 10,000 PYs, 15.62 per 10,000 PYs, and 23.44 per 10,000 PYs for ARC-DIBH 3A plans and 41.12 per 10,000 PYs, 15.59 per 10,000 PYs, and 22.73 per 10,000 PYs for ARC-DIBH 4A plans. Both techniques provided negligibly low NTCPs for all OARs. CONCLUSION: The study shows that VMAT-DIBH provides better OAR sparing against high doses. However, the large low-dose-bath (≤ 5 Gy) is still a concern due to the fact that a larger volume of normal tissues exposed to lower doses may increase a radiation-induced risk of secondary cancer.


Assuntos
Neoplasias da Mama , Neoplasias Induzidas por Radiação , Segunda Neoplasia Primária , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Neoplasias Unilaterais da Mama , Humanos , Feminino , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Unilaterais da Mama/radioterapia , Neoplasias da Mama/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Radioterapia Conformacional/métodos , Órgãos em Risco/efeitos da radiação
18.
Strahlenther Onkol ; 199(6): 574-584, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36930248

RESUMO

PURPOSE: The outcome of radiotherapy (RT) for prostate cancer (PCA) depends on the delivered dose. While the evidence for dose-escalated RT up to 80 gray (Gy) is well established, there have been only few studies examining dose escalation above 80 Gy. We initiated the present study to assess the safety of dose escalation up to 84 Gy. METHODS: In our retrospective analysis, we included patients who received dose-escalated RT for PCA at our institution between 2016 and 2021. We evaluated acute genitourinary (GU) and gastrointestinal (GI) toxicity as well as late GU and GI toxicity. RESULTS: A total of 86 patients could be evaluated, of whom 24 patients had received 80 Gy and 62 patients 84 Gy (35 without pelvic and 27 with pelvic radiotherapy). Regarding acute toxicities, no > grade 2 adverse events occurred. Acute GU/GI toxicity of grade 2 occurred in 12.5%/12.5% of patients treated with 80 Gy, in 25.7%/14.3% of patients treated with 84 Gy to the prostate only, and in 51.9%/12.9% of patients treated with 84 Gy and the pelvis included. Late GU/GI toxicity of grade ≥ 2 occurred in 4.2%/8.3% of patients treated with 80 Gy, in 7.1%/3.6% of patients treated with 84 Gy prostate only, and in 18.2%/0% of patients treated with 84 Gy pelvis included (log-rank test p = 0.358). CONCLUSION: We demonstrated that dose-escalated RT for PCA up to 84 Gy is feasible and safe without a significant increase in acute toxicity. Further follow-up is needed to assess late toxicity and survival.


Assuntos
Gastroenteropatias , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Estudos Retrospectivos , Radioterapia de Intensidade Modulada/efeitos adversos , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/tratamento farmacológico , Sistema Urogenital , Próstata , Gastroenteropatias/etiologia , Dosagem Radioterapêutica
19.
BMC Cancer ; 23(1): 515, 2023 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-37280543

RESUMO

BACKGROUND: Our purpose was to ensure that the dose constraints of the organs at risk (OARs) were not exceeded while increasing the prescription dose to the planning target volume (PTV) from 45 to 50.4 Gray (Gy) with the dynamic intensity-modulated radiotherapy (IMRT) technique. While trying for this purpose, a new dynamic IMRT technique named 90° angled collimated dynamic IMRT (A-IMRT) planning was developed by us. METHODS: This study was based on the computed tomography data sets of 20 patients with postoperatively diagnosed International Federation of Gynecology and Obstetrics stage 2 endometrial carcinoma. For each patient, conventional dynamic IMRT (C-IMRT, collimator angle of 0° at all gantry angles), A-IMRT (collimator angle of 90° at gantry angles of 110°, 180°, 215°, and 285°), and volumetric modulated arc therapy (VMAT) were planned. Planning techniques were compared with parameters used to evaluate PTV and OARs via dose-volume-histogram analysis using the paired two-tailed Wilcoxon's signed-rank test; p < 0.05 was considered indicative of statistical significance. RESULTS: All plans achieved adequate dose coverage for PTV. Although the technique with the lowest mean conformality index was A-IMRT (0.76 ± 0.05) compared to both C-IMRT (0.79 ± 0.04, p = 0.000) and VMAT (0.83 ± 0.03, p = 0.000), it protected the OARs especially the bladder (V45 = 32.84 ± 2.03 vs. 44.21 ± 6.67, p = 0.000), rectum (V30 = 56.18 ± 2.05 vs. 73.80 ± 4.75, p = 0.000) and both femoral heads (V30 for right = 12.19 ± 1.34 vs. 21.42 ± 4.03, p = 0.000 and V30 for left = 12.58 ± 1.48 vs. 21.35 ± 4.16, p = 0.000) better than C-IMRT. While the dose constraints of the bladder, rectum and bilateral femoral heads were not exceeded in any patient with A-IMRT or VMAT, they were exceeded in 19 (95%), 20 (100%) and 20 (100%) patients with C-IMRT, respectively. CONCLUSIONS: OARs are better protected when external beam radiotherapy is applied to the pelvis at a dose of 50.4 Gy by turning the collimator angle to 90° at some gantry angles with the dynamic IMRT technique in the absence of VMAT.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radiometria , Pelve , Órgãos em Risco
20.
BMC Cancer ; 23(1): 445, 2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37194056

RESUMO

BACKGROUND: we assessed the performance of the optimization algorithms by comparing volumetric modulated arc therapy generated by a progressive resolution optimized (VMATPRO) and photon optimizer (VMATPO) in terms of plan quality, MU reduction, sparing of the spinal cord (or cauda equina), and plan complexity. METHODS: Fifty-seven patients who received spine stereotactic ablative radiotherapy (SABR) with tumors located in the cervical, thoracic, and lumbar spine were retrospectively selected. For each patient, VMATPRO and VMATPO with two full arcs were generated with using the PRO and PO algorithms. For dosimetric evaluation, the dose-volumetric (DV) parameters of the planning target volume (PTV), organs at risk (OARs), the corresponding planning organs at risk (PRV), and 1.5-cm ring structure surrounding the PTV (Ring1.5 cm) were calculated for all VMAT plans. The total number of monitor units (MUs) and the modulation complexity score for the VMAT (MCSv) were compared. To investigate the correlations of OAR sparing to plan complexity, Pearson's and Spearman's correlation tests were conducted between the two algorithms (PO - PRO, denoted as Δ) in the DV parameters for normal tissues, total MUs, and MCSv. RESULTS: For the PTVs, Target conformity and dose homogeneity in the PTVs of VMATPRO were better than those of VMATPO with statistical significance. For the spinal cords (or cauda equine) and the corresponding PRVs, all of the DV parameters for VMATPRO were markedly lower than those for VMATPO, with statistical significance (all p < 0.0001). Among them, the difference in the maximum dose to the spinal cord between VMATPRO and VMATPO was remarkable (9.04 Gy vs. 11.08 Gy with p < 0.0001). For Ring1.5 cm, no significant difference in V115% for VMATPRO and VMATPO was observed. CONCLUSIONS: The use of VMATPRO resulted in improved coverage and uniformity of dose to the PTV, as well as OARs sparing, compared with that of VMATPO for cervical, thoracic, and lumbar spine SABR. Better dosimetric plan quality generated by the PRO algorithm was observed to result in higher total MUs and plan complexity. Therefore, careful evaluation of its deliverability should be performed with caution during the routine use of the PRO algorithm.


Assuntos
Radioterapia de Intensidade Modulada , Animais , Cavalos , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Medula Espinal , Órgãos em Risco , Vértebras Lombares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA